IBS04SF15M5PC [CARLOGAVAZZI]
IBS04, ICS05 IO-Link 3-wire DC;型号: | IBS04SF15M5PC |
厂家: | Carlo Gavazzi |
描述: | IBS04, ICS05 IO-Link 3-wire DC |
文件: | 总12页 (文件大小:1355K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
IBS04, ICS05 IO-Link 3-wire DC
Miniaturized proximity inductive sensors with IO-Link communication
Benefits
• A complete family. Available in Ø4 and M5 male
thread robust stainless steel housings with an operating
distance of 0.8 to 1.3 mm.
• High speed detection. IBS04 and ICS05 inductive
proximity sensors can reach an operating frequency of
up to 6 kHz.
• Easy to install. The active face can be installed flush
with the surrounding area. The user can choose between
2 m PVC cable and M8-disconnect plug versions.
• High precision. The onboard advanced microcontroller
ensures better stability with respect to environmental
influences, with highly reliable repeatable measurements
between -25 and +70°C.
• Easy customization to specific OEM requests:
different cable lengths and materials, special labelling,
customized pig-tail solutions with special cables and
connectors are possible on request.
Description
Only for IO-Link sensors
• The output can be operated either as a switching output
or in IO-Link mode.
• Fully configurable via IO-Link v1.1. Electrical outputs
can be configured as PNP/NPN/Push-pull, normally
open or normally closed.
• Timer functions can be set, such as switch-on and
switch-off delay
• Adjustable sensing distance and hysteresis: sensing
distance can be set to 62% or 100% of the maximum
sensing distance
The IBS04 and ICS05 series represent the optimal
solution for industrial automation equipment in
applications where space is limited, including tool-
selection, robotic position-sensing and control of
micro-mechanisms. The advanced electronics
is enclosed in a robust stainless steel housing.
The availability of the M8-plug and 2m-PVC cable
connection allow flexible mounting.
On-board IO-Link communication opens up many
possibilities, such as easy configuration and set-
up of the devices and advanced parameter setting.
• Temperaturemonitoring:overorunder-runtemperature
alarms can be set
•
Applications
• Non contact detection of metal objects in general position-sensing and presence-sensing in industrial applications
• Particularly suitable for rotational speed monitoring thanks to the high operating frequency
Main functions
• Integrated diagnostic function with flashing LED in the event of a short circuit or overload
10/07/2018 IBS04, ICS05 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
1
IBS04, ICS05 IO-Link 3-wire DC
IO-Link sensors
• The devices can be operated in IO-Link mode once connected to an IO-Link master, or in standard I/O mode.
• In IO-Link mode the switching signals of the sensor are made available in the process data via the IO-Link interface.
• Several sensor functions can be set via the IO-Link interface:
► Adjustable switching distance: 62% or 100% of the maximum switching distance.
► Adjustable hysteresis: standard or increased value.
► Divider function: the sensor gives a signal after a specified number of actuation pulses has been
reached.
► Switch-on delay: the switching pulse is generated after the sensor actuation.
► Switch-off delay: the generation of the switch signal is delayed by the set time after sensor actuation.
► Temperature error: temperature is out of specifications.
► Temperature over-run and under-run: temperature is out of the limits defined by the user.
References
Order code
I
S
F
Enter the code option instead of
Code
I
Option Description
-
B
C
Inductive sensor
Cylindrical housing with smooth barrel
Cylindrical housing with threaded barrel
Stainless steel housing
Ø4 housing
S
F
-
04
05
S
M5 housing
Short housing with smooth barrel
Short housing with thread length of 23 mm
Flush
S23
-
08
15
M5
A2
NO
NC
PO
PC
IO
Sensing distance 0.8mm
Sensing distance 1.3mm
M8 plug
2 m PVC cable
NPN – normally open output
NPN – normally closed output
PNP – normally open output
PNP – normally closed output
IO-Link programmable version
Additional characters can be used for customized versions.
10/07/2018 IBS04, ICS05 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
2
IBS04, ICS05 IO-Link 3-wire DC
Selection guide
Ø4 Standard and extended range, short housing
Rated
Con-
nec-
tion
Ordering no.
NPN,
Ordering no.
PNP,
Ordering no.
NPN,
Normally closed
Ordering no.
PNP,
Normally closed
operating
distance
Sn
Normally open
Normally open
Cable
Plug
Cable
Plug
0.8 mm
IBS04SF08A2NO
IBS04SF08M5NO
IBS04SF15A2NO
IBS04SF15M5NO
IBS04SF08A2PO
IBS04SF08M5PO
IBS04SF15A2PO
IBS04SF15M5PO
IBS04SF08A2NC
IBS04SF08M5NC
IBS04SF15A2NC
IBS04SF15M5NC
IBS04SF08A2PC
IBS04SF08M5PC
IBS04SF15A2PC
IBS04SF15M5PC
0.8 mm
1.3 mm
1.3 mm
M5 Standard and extended range, short housing
Rated
Con-
nec-
tion
Ordering no.
NPN,
Ordering no.
PNP,
Ordering no.
NPN,
Normally closed
Ordering no.
PNP,
Normally closed
operating
distance
Sn
Normally open
Normally open
Cable
Plug
Cable
Plug
0.8 mm
ICS05S23F08A2NO
ICS05S23F08M5NO
ICS05S23F15A2NO
ICS05S23F15M5NO
ICS05S23F08A2PO
ICS05S23F08M5PO
ICS05S23F15A2PO
ICS05S23F15M5PO
ICS05S23F08A2NC
ICS05S23F08M5NC
ICS05S23F15A2NC
ICS05S23F15M5NC
ICS05S23F08A2PC
ICS05S23F08M5PC
ICS05S23F15A2PC
ICS05S23F15M5PC
0.8 mm
1.3 mm
1.3 mm
IO-Link types
Con-
Body
nec-
style
tion
Rated operating distance
Sn
Output type
Ordering no.
Cable
Plug
Cable
Plug
Ø4
Ø4
M5
M5
IBS04SF15A2IO
IBS04SF15M5IO
ICS05S23F15A2IO
ICS05S23F15M5IO
Configurable: NPN/PNP/push-pull
NO/NC
Configurable: 0.8 or 1.3mm
Factory setting: 1.3mm
Factory setting: PNP, NO
10/07/2018 IBS04, ICS05 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
3
IBS04, ICS05 IO-Link 3-wire DC
Structure
IBS04
A
A
B
A
B
C
B
C
Element
A
Component
Sensing face
Function
Flush
Yellow LED: Output flashing: short circuit or
overload indication
For plug versions only
B
C
LED
M8, 3 pin, male connector
ICS05
A
B
A
B
C
A
B
C
D
C
D
Element
Component
Sensing face
2 nuts
Function
Flush
For sensor mounting
A
B
Yellow LED: Output flashing: short circuit or
overload indication
For plug versions only
C
D
LED
M8, 3 pin, male connector
10/07/2018 IBS04, ICS05 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
4
IBS04, ICS05 IO-Link 3-wire DC
Sensing
Detection
Rated operating distance Sn
0.8 mm standard range or 1.3 mm extended range
The operating distance is measured according to IEC 60947-5-2, using a
standard target moving axially.
This target is square shape 1 mm thickness, made of steel e.g. type Fe 360
as defined in ISO 630 and it shall be of the rolled finish.
The length of the side of the square is equal to
Reference target
– the diameter of the circle inscribed on the active surface of the sensing face,
or
– three times the rated operating distance Sn whichever is greater
Assured operating sensing distance
(Sa)
0 ≤ Sa ≤ 0.81 x Sn (e.g. with Sn of 1.3 mm, Sa is 0 ... 1.053 mm)
Effective operating distance (Sr)
Usable operating distance (Su)
Temperature drift
0.9 x Sn ≤ Sr ≤ 1.1 x Sn
0.9 x Sr ≤ Su ≤ 1.1 x Sr
≤ +/-10%
Hysteresis (H)
1...20%
S
S: sensor
T: target
Y
X
T
Distance [Thou]
Distance [Thou]
-4
4
12
20
28
36
44
52
60
3
2,5
2
118
-3,9
2,5
0
3,9
7,8
11,7 15,6 19,5 23,4 27,3 31,2 35,1
98,4
94,4
70,8
47,2
23,6
0
2
1,5
1
73,8
49,2
24,6
0
1,5
1
T
T
0,5
0
0,5
0
S
S
-0,5
-1
-0,5
-1
-23,6
-47,2
-70,8
-94,4
-118
-24,6
-49,2
-73,8
-98,4
-1,5
-2
-1,5
-2
-2,5
-3
-2,5
-0,1
0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
-0,1
0
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9
1
1,1 1,2 1,3 1,4 1,5 1,6
Distance [mm]
Distance [mm]
Fig. 1 Ø4 standard range
Fig. 2 Ø4 extended range
10/07/2018 IBS04, ICS05 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
5
IBS04, ICS05 IO-Link 3-wire DC
Distance [Thou]
Distance [Thou]
11,7 15,6 19,5 23,4 27,3 31,2 35,1
-4
4
12
20
28
36
44
52
60
3,5
3
138
115
92
-3,9
0
3,9
7,8
3
2,5
2
118
2,5
2
94,4
70,8
47,2
23,6
0
69
1,5
1
1,5
1
46
T
T
23
0,5
0
0,5
0
0
S
S
-0,5
-1
-0,5
-1
-23,6
-47,2
-70,8
-94,4
-118
-23
-46
-69
-92
-115
-138
-1,5
-2
-1,5
-2
-2,5
-3
-2,5
-3
-0,1
0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
-3,5
-0,1
0
0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9
1
1,1 1,2 1,3 1,4 1,5 1,6
Distance [mm]
Distance [mm]
Fig. 3 M5 standard range
Fig. 4 M5 extended range
Sensors with IO-Link communication
Rated operating distance Sn
Hysteresis (H)
Programmable via IO-Link: 62% or 100% of the maximum Sn=1.3mm
Programmable via IO-Link: standard or increased
Correction factors
The specific operating distance Sn refers to defined measuring conditions. The following data have to be
considered as general guidelines.
Fe360 : Steel
CrNi : Chrome-nickel
CuZn : Brass
Al : Aluminium
Cu : Copper
Sr : Effective operating distance
Fig. 5 The rated operating distance is reduced by
the use of metals and alloys other than Fe360. The
most important reduction factors for inductive prox-
imity sensors are shown in the figure.
Accuracy
Repeat accuracy (R)
≤ 5%
10/07/2018 IBS04, ICS05 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
6
IBS04, ICS05 IO-Link 3-wire DC
Features
Power Supply
Rated operational voltage (Ub)
Ripple (Urpp
10 to 30 VDC (ripple included)
≤ 10%
)
No load supply current (Io)
Power ON delay (tv)
≤ 15 mA
≤ 50 ms
Outputs
Standard sensors
IO-Link sensors
Configurable via IO-Link: PNP, NPN
or push-pull
Output functions
NPN or PNP by sensor type
Factory setting: PNP
Configurable via IO-Link: N.O. or N.C.
Factory setting: N.O.
Output configuration
N.O. and N.C. by sensor type
≤ 100 mA
Output current (Ie)
OFF-state current (Ir)
(only for PNP or NPN output)
≤ 100 μA
Voltage drop (Ud)
Protection
Voltage transient
Max. 1.2 VDC @ 100 mA
Short-circuit, reverse polarity and transients
1 kV/0.5 J
Response times
≤ 6 KHz
≤ 4.5 KHz
Ø4, M5 standard range (Sn: 0.8mm)
Ø4, M5 extended range (Sn: 1.3mm)
Operating frequency (f)
Indication
Standard IO mode:
Yellow LED
Output
Description
N.O. output, target not present
N.C. output, target present
OFF
OFF
N.O. output, target present
N.C. output, target not present
ON
ON
f: 2Hz
f: 1Hz
Short-circuit or overload
Temperature alarm (if enabled)
Blinking
IO-Link mode:
• LED is ON for 0.75 s and OFF for 0.075 s
10/07/2018 IBS04, ICS05 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
7
IBS04, ICS05 IO-Link 3-wire DC
• Possibility to disable the LED
Environmental
Operating: -25° to +70°C (-13° to +158°F)
Storage: -30° to +80°C (-22° to +176°F)
Operating: 35% to 95%
Storage: 35% to 95%
10 to 55 Hz, amplitude 1.0 mm; sweep cycle 5
min; in X, Y and Z direction
Ambient temperature
Ambient humidity
Vibration
IEC 60068-2-6
Shock
Degree of protection
30 G /11 ms. 10 shocks in X, Y and Z direction
IP67
IEC 60068-2-27
IEC 60529; EN 60947-1
Compatibility and conformity
8 kV air discharge
4 kV contact discharge
IEC 61000-4-2 Electrostatic discharge
IEC 61000-4-3 Radiated radiofre-
quency
IEC 61000-4-4 Burst immunity
IEC 61000-4-6 Conducted radio fre-
quency
3 V/m
2 kV
3 V
EMC protection
IEC 61000-4-8 Power frequency mag-
netic fields
30 A/m
MTTFd
4467 years @ 50°C (122°F)
®
Approvals
CCC is not required for products rated ≤ 36 V
Mechanical data
Weight (including 2 nuts and the
packaging) max.
Cable version: Ø4: 33.1g; M5: 35.4g
Plug version: Ø4: 5.6g; M5: 7.6g
Mounting
Flush mountable
Housing: stainless steel AISI304
Front cap: nylon polymite 66 (PA66)
Material
Max tightening torque
(for ICS05 only)
1.5 Nm
Electrical connection
Cable
Ø4 and M5: 2m, 3 x 0.13 mm2, Ø3.2 mm, PVC, grey, oil proof
Plug
M8 x 1 quick disconnect, 3 pin, male connector
IO-Link version only
Communication
Via IO-Link V1.1 or via standard I/O
10/07/2018 IBS04, ICS05 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
8
IBS04, ICS05 IO-Link 3-wire DC
Connection Diagrams
+
+
1 BN
1 BN
4 BK
4 BK
3 BU
Fig. 6 NPN - Normally open
1 BN
3 BU
-
-
Fig. 7 NPN - Normally closed
+
+
1 BN
4 BK
4 BK
3 BU
3 BU
-
-
Fig. 8 PNP - Normally open
Fig. 9 PNP - Normally closed
+
1 BN
4 BK
Out/IO-Link
3 BU
-
Fig. 10 IO-Link
Colour code
BN: brown
BK: black
BU: blue
10/07/2018 IBS04, ICS05 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
9
IBS04, ICS05 IO-Link 3-wire DC
Dimensions [mm]
IBS04 [mm]
4
1
3
17.7
23.2
3.9
28.2
17.7
6.9
38.2
Fig. 11 Short body, flush version, cable
Fig. 12 Short body, flush version, plug
ICS05 [mm]
4
1
3
17.7
17.7
2.5
SW 7
2.5
SW 7
3.9
2 x Lock washer
23
28.2
2 x Lock washer
6.9
23
38.2
Fig. 13 Short body, flush version, cable
Fig. 14 Short body, flush version, plug
10/07/2018 IBS04, ICS05 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
10
IBS04, ICS05 IO-Link 3-wire DC
Installation
Ø4, M5 flush
d
d
d
**
≥ 3 x Sn
d
Fig. 15 Flush sensor, when installed in damping
Fig. 16 Flush sensors, when installed together in
material
damping material
Sensors installed opposite each other
≥ 6 x Sn
Fig. 17 For sensors installed opposite each other, a minimum space of 6 x Sn (the nominal sensing dis-
tance) must be observed
** Free zone or non-damping material
Sn: nominal sensing distance
d: sensor diameter: 4 mm for IBS04, 5 mm for ICS05
10/07/2018 IBS04, ICS05 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
11
IBS04, ICS05 IO-Link 3-wire DC
Delivery contents and compatible components
Delivery contents
• Inductive proximity switch
• 2 fixing nuts (only for ICS05)
• 2 lock washers (only for ICS05)
• Packaging: plastic bag
CARLO GAVAZZI compatible components
• Connector type: CONB53... series to be purchased separately
Further reading
Information
Where to find it
QR
IO-Link manual
Connectors
http://www.productselection.net/MANUALS/UK/IOL_IM.pdf
http://www.productselection.net/Pdf/UK/CONB5.pdf
COPYRIGHT ©2018
Content subject to change. Download the PDF: www.productselection.net
10/07/2018 IBS04, ICS05 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
12
相关型号:
©2020 ICPDF网 联系我们和版权申明