EM2696AV63HO3S1PFA [CARLOGAVAZZI]
Energy Management Energy Analyzer Type EM26 96;型号: | EM2696AV63HO3S1PFA |
厂家: | Carlo Gavazzi |
描述: | Energy Management Energy Analyzer Type EM26 96 |
文件: | 总13页 (文件大小:579K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Energy Management
Energy Analyzer
Type EM26 96
● Class 1 (kWh) according to EN62053-21
● Class B (kWh) according to EN50470-3
● Class 2 (kvarh) according to EN62053-23
● Accuracy 0.5% RDG (current/voltage)
● Dual colour backlight: no backlight, blue or white (selectable)
● Energy analyzer
● Instantaneous variables readout: 4 DGT
● Energies/gas/water readout: 8 DGT
●
System variables: VLL, VLN, Admd, VA, VAdmd, VAdmd max, W,
Wdmd, Wdmd max, var, PF, Hz, Phase-sequence.
● Single phase variables: VLL, VLN, A, VA, W, var, PF
● Energy measurements: total and partial kWh and kvarh or
based on 4 different tariffs; single phase measurements
● Gas, cold water, hot water, kWh remote heating measurements
● Hour counter (6+2 DGT)
● Harmonic analysis (FFT) up to 15th harmonic (current/voltage)
● TRMS measurements of distorted sine waves (voltages/currents)
● Universal power supply: 90 to 260AC/VDC
● M-bus communication by means of VMU-B adapter
● Application adaptable display and programming
procedure (Easyprog function)
●
3 digital inputs for tariff selection, DMD synch or gas/water (hot-
cold) and remote heating metering (on request)
● 3 digital outputs for pulses or for alarms or as a mix of them
● Easy connections management
(on request)
● Certified according to MID Directive (option PF only):
see “how to order” below
● Front dimensions: 96x96mm
● Protection degree (front): IP50
● Other versions available (not certified, option XX):
● RS485 serial output (on request) (MODBUS-RTU), iFIX SCADA
compatibility
see “how to order” on the next page
Product Description
Three-phase energy analyzer
with built-in configuration joy-
stick and LCD data displaying;
particularly indicated for active
and reactive energy metering
and for cost allocation. Housing
the meter can be provided with
digital outputs that can be used:
for pulses proportional to the
active and reactive energy being
measured or for alarm outputs,
or for remote control. RS485
communication port and 3 digi-
tal inputs are available as an
option.
for panel mounting with IP50
(front) protection degree. Exter-
nal Current and potential trans-
formers connection. Moreover
How to order
Model
Range code
System
EM26 96 AV5 3 H O3 S1 PF A
Certified according to MID Directive, Annex
"B" + Annex "D" for legal metrology relevant to
active electrical energy meters (see Annex MI-
003 of MID). Can be used for fiscal (legal)
MID
Power supply
Input/Output
Communication
Options
metrology. Only the total positive energy meter is certified
according to MID.
Measurement
Type Selection
Options
Communication
Range codes
System
3:
AV5: 230 VLN/400VLL
PF:
Certified according to
MID Directive, Annex
"B" + Annex "D" for
legal metrology relevant
to active electrical
XX:
S1:
none
RS485 port
3-phase, 4-wire;
1/5(10)A
VLN : 160 V to 480 VLN
VLL : 277 V to 830 VLL
Input/Output
Power supply
AV6: 120 VLN/208VLL
1/5(10)A
energy meters (see
Annex MI-003 of MID).
Can be used for fiscal
(legal) metrology.
VLN : 40 V to 144 VLN
VLL : 70 V to 250 VLL
O1:
O3:
single open collector type
H:
90 to 260VAC/DC (48
to 62Hz)
(pulse or alarm)
3 open collector type
(mixed combination of
pulse, alarm and/or
remote output)
R2:
I3:
dual relay type (functions
as per “O3”)
3 digital inputs for tariff
selection or Gas/water/
energy/remote heating
metering
Measurement
A:
The power is always
integrated (both in case
of positive and negative
power) and the total
energy meter is certified
according to MID.
B:
Only the total positive
energy meter is certified
according to MID. The
negative energy meter
is not certified according
to MID.
AV5
AV6
3
H
O1
O3
R2
XX
S1
NOTE: please check the
availability of the needed
code on the verification path
diagram on left before order.
A
B
PF
I3
S1
Specifications are subject to change without notice EM2696 DS ENG 061014
1
EM26 96
How to order
Model
Range code
System
Power supply
Input/Output
Communication
Options
EM2696 AV53HO3S1XX
STANDARD
Not certified according to MID directive. Cannot be
used for fiscal (legal) metrology.
Type Selection
Range codes
System
Power supply
Input/Output
AV5: 230 VLN/400VLL
3:
balanced and
H:
90 to 260VAC/DC
(48 to 62Hz)
O1:
O3:
single open collector
1/5(10)A
unbalanced load:
3-phase, 4-wire;
3-phase, 3-wire;
2-phase, 3-wire;
1-phase, 2-wire
type (pulse or alarm)
3 open collector type
(mixed combination of
pulse, alarm and/or
remote output)
dual relay type (functions
as per “O3”)
3 digital inputs for tariff
selection or Gas/water/
energy/remote heating
metering
VLN : 160 V to 480 VLN
VLL : 277 V to 830 VLL
AV6: 120 VLN/208VLL
1/5(10)A
VLN : 40 V to 144 VLN
VLL : 70 V to 250 VLL
R2:
I3:
Communication
XX:
S1:
none
RS485 port
Options
XX:
none
AV5
AV6
3
H
O1
O3
R2
I3
XX
S1
XX
NOTE: please check the
availability of the needed
code on the verification path
tables on left before order.
2
Specifications are subject to change without notice EM2696 DS ENG 061014
EM26 96
Input specifications
Rated inputs
System type: 3
exceeding the “Continuous
inputs overload” (maximum
measurement capacity)
Max. instantaneous
variables: 9999; energies:
99 999 999. Min. instanta-
neous variables: 0; ener-
gies 0.00
Current type
Galvanic insulation by
means of built-in CT’s
AV5 and AV6: 1/5(10)A
Current range (by CT)
Voltage by direct connection
or VT/PT
Max. and Min. indication
AV5: 230 VLN/400VLL;
AV6: 120 VLN/208VLL
Ib: see below, Un: see below
Accuracy (Display + RS485)
LEDs
Red LED (Energy
(@25°C 5°C,R.H. 60%,
50 5Hz/60 5Hz)
AV5 model
consumption), according to
EN50470-3, EN62052-11
0.001 kWh/kvarh by pulse
if CT ratio by VT ratio is ≤7;
0.01 kWh/kvarh by pulse if
CT ratio by VT ratio is > 7.1
≤ 70.0;
0.1 kWh/kvarh pulse if CT
ratio by VT ratio is > 70.1 ≤
700.0;
1 kWh/kvarh by pulse if CT
ratio by VT ratio is > 700.1;
1000 imp./kWh/kvarh.
Max frequency: 16Hz
In: 5A, Imax: 10A; Un: 160
to 480VLN (277 to 830VLL)
In: 5A, Imax: 10A; Un: 40 to
144VLN (70 to 250VLL)
AV6 model
Current
AV5, AV6 models
From 0.002In to 0.2In:
(0.5% RDG +3DGT)
From 0.2In to Imax:
(0.5% RDG +1DGT).
In the range Un: (0,5%
RDG +1DGT)
Phase-neutral voltage
Phase-phase voltage
In the range Un: (1% RDG
+1DGT)
Frequency
Active and Apparent power
Power Factor
0.1Hz (50 5Hz/60 5Hz)
(1%RDG +2DGT)
[0.001+1%(1.000 - “PF
RDG”)]
(2%RDG +2DGT)
Class 1 according to
EN62053-21; class B
according to EN50470-3.
Class 2 according to
EN62053-23
In: 5A, Imax: 10A;
0.1 In: 0.5A.
Start up current: 10mA
THD up to 15th harmonic
3% reading
Measurements
See “List of the variables
that can be connected to:”
TRMS measurements of
distorted wave forms.
By means of external CT’s
3 (15A max. peak)
Method
Reactive power
Active Energy
Coupling type
Crest factor
Current Overloads
Continuous
For 500ms
Voltage Overloads
Continuous
For 500ms
Input impedance
208VL-L (AV6)
400VL-L (AV5)
10A, @ 50Hz
200A, @ 50Hz
Reactive Energy
AV5, AV6 models
1.2 Un
2 Un
Harmonic distortion
>1MΩ
>1MΩ
< 0.3VA
Energy additional errors
Influence quantities
1/5(10) A (AV5-AV6)
Frequency
Joystick
According to EN62053-21,
EN62053-23
≤200ppm/°C
1600 samples/s @ 50Hz
1900 samples/s @ 60Hz
750 msec
50 5Hz/60 5Hz
Temperature drift
Sampling rate
For variable selection:
programming of the
instrument working
parameters and Wdmd
max reset
Display refresh time
Display
3 lines (1 x 8 DGT;
2 x 4 DGT)
Type
LCD, h 9.5mm, dual colour
backlight (selectable)
Instantaneousvariablesread-out 4 DGT
Energies
Exported: Total
6+1DGT or 7DGT (with “-“
sign).
Imported: 6+2, 7+1 or
8DGT
EEEE indication when the
value being measured is
Overload status
Specifications are subject to change without notice EM2696 DS ENG 061014
3
EM26 96
Output specifications
Digital outputs
Relay output
Physical outputs
Purpose
Pulse type
Max. 2
Number of outputs
Up to 3, independent.
For alarm output, pulse
output or remote control.
Relay, SPST type
Programmable from 0.001
to 10.00 kWh/kvarh per
pulse.
Type
AC 1-5A @ 250VAC
DC 12-5A @ 24VDC
AC 15-1.5A @ 250VAC
DC 13-1.5A @ 24VDC
4000 VRMS outputs to
measuring input.
Type
Outputs connectable to the
energy meters (Wh/varh)
TON selectable (30 ms or
100 ms) according to
EN62053-31
TOFF: ≥120ms, according to
EN62052-31
Pulse duration
Insulation
4000 VRMS outputs to
power supply input.
Alarm type
Number of outputs
Alarm modes
RS485
Type
Up to 3, independent
Up alarm, down alarm (see
the table “List of the
variables that can be
connected to”)
From 0 to 100% of the
display scale
From 0 to full scale
0 to 255s
Selectable: normally
de-energized or normally
energized
700ms, filters excluded.
Set-point on-time delay: “0 s”
The digital ouputs status can
be managed by means of
serial communication RS485,
if programmed as remote.
The 3 digital outputs can
also work as a triple pulse
output, triple alarm output,
or in any other combination.
Multidrop, bidirectional
(static and dynamic
variables)
Connections
2-wire
Max. distance 1000m
(without amplifier)
Termination directly on the
instrument
247, selectable by means
of the front joystick
MODBUS/JBUS (RTU)
Set-point adjustment
Hysteresis
On-time delay
Output status
Addresses
Protocol
Data (bidirectional)
Dynamic (reading only)
Min. response time
Remote control
System and phase
variables: see table “List of
variables...”
Static (reading and writing) All the configuration
parameters.
Data format
1 start bit, 8 data bit, no
parity,1 stop bit
4800, 9600 bits/s
Note
Baud-rate
Driver input capability
1/5 unit load
Maximum 160 transceivers
on the same bus, which
can be expanded with
signal amplifiers.
By means of optocouplers,
4000 VRMS output to
measuring input.
Static output
Physical outputs
Purpose
Max. 3
For pulse output, alarm
output or remote control.
VON 1.2 VDC/ max. 100 mA
VOFF 30 VDC max.
By means of optocouplers,
4000 VRMS output to
measuring inputs,
Insulation
Signal
Insulation
4000 VRMS output to
power supply input
4000 VRMS output to
power supply input.
Digital input specifications
Number of inputs
Input frequency
Prescaler adjustment
3
Working modes
Selectable:
20Hz max, duty cycle 50%
From 0.001 to 999.9 m3 or
kWh/pulse
5VDC +/- 5%
10mA max
• total and partial energy
meters (kWh and kvarh)
managed by time periods
(t1-t2-t3-t4), W dmd
synchronisation (the
synchronisation is made
every time the tariff
Contact measuring voltage
Contact measuring current
Input impedance
680Ω
Contact resistance
≤100Ω, closed contact
≥500kΩ, open contact
changes) and GAS (m3) or
WATER (hot-cold m3) or
4
Specifications are subject to change without notice EM2696 DS ENG 061014
EM26 96
Digital input specifications (cont.)
remote heating (kWh)
meters or external kWh
meter;
• total energy (kWh, kvarh)
and GAS, WATER (hot-cold
m3) and remote heating
meters or external kWh
meter, 3 choices only.
The energy metering is
only made by means of the
analogue inputs.
By means of optocouplers,
4000 VRMS digital inputs
to measuring inputs.
4000 VRMS digital inputs
to power supply input.
• total and partial energy
meters (kWh and kvarh)
managed by time periods
(t1-t2), W dmd synchroni-
sation (the synchronisation
is made independently of
the tariff selection) and
GAS (m3) or WATER
Note
Insulation
(hot-cold m3) or remote
heating (kWh) meters or
external kWh meter;
Software functions
Password
Numeric code of max. 4
digits; 2 protection levels
of the programming data:
Password “0”, no protec-
tion;
Password from 1 to 9999,
all data are protected
current) being measured
cannot exceed 66 MW for
AV5_X models and 62 MW
for AV6_X models. If the
currents and/or voltages
being measured exceed
their maximum limits, the
display shows the error
message “EEEE”.
For EN50470-3 compliant
applications the maximum
power being measured is
25 MW.
1st level
2nd level
System selection
System 3-Pn unbalanced load 3-phase (4-wire);
3-phase (3-wire).
System 3-P 1 balanced load
3-phase (3-wire) one cur-
rent and 3-phase to phase
voltage measurements.
3-phase (4-wire) one cur-
rent and one-phase (L1) to
neutral voltage measure-
ment.
Filter
Operating range
0 to 100% of the input dis-
play scale
1 to 32
Filtering coefficient
Filter action
System 2-P
System 1-P
Transformer ratio
VT (PT)
2-phase (3-wire).
1-phase (2-wire).
Measurements, serial out-
put (fundamental variables:
V, A, W and their derived
ones).
Up to 3 variables per page
See « Display pages » 8
different set of variables
available (see « Display
pages ») according to the
application being selected
In case of alarm and if the
relevant function is
enabled, the display
changes the colour alterna-
tively from white backlight
to blue backlight and vice
versa.
By means of the front
joystick:
- dmd and max. dmd;
- total energies and
gas/water: kWh, kvarh;
- partial energies and
tariffs: kWh, kvarh
Up to the 15th harmonics
on single current and
voltage
1.0 to 999.9 / 1000 to
6000.
1.0 to 999.9 / 1000 to 9999
/ 10.00k to 60.00k.
Transformer ratio: VT (PT):
1.0 to 999.9 / 1000 to
6000, CT: 1.0 to 999.9 /
1000 to 9999 / 10.00k to
60.00k (only AV5_X and
AV6_X). VT (PT) = 1.0
(fixed) for AV5_PF mod-
els.The maximum VT by CT
ratio is 3150 for AV5_PF
models, 4629 for AV5_X
models.The maximum VT
by CT ratio is 5448 for
AV6_PF models, 14529 for
AV6_X models. Note 1: for
MID complaint applications
the maximum power being
measured is 25 MW for
AV5_PF models. Note 2:
for non-MID complaint
applications the maximum
power (calculated as maxi-
mum input voltage and
Displaying
CT
Alarm highlight
Reset
Harmonic analysis
Specifications are subject to change without notice EM2696 DS ENG 061014
5
EM26 96
Software functions (cont.)
Easy connection function
For all the display selections,
For these latter selections
the energies can be either
“imported” or “exported”
depending on the current
direction.
both energy and power
measurements are inde-
pendent of the current
direction. The displayed
energy is always “imported”
with the only exception of
“F” and “H” types (see
“display pages” table).
General specifications
Operating temperature
-25°C to +55°C (-13°F to
Immunity to conducted
disturbances
131°F) (R.H. from 0 to 90%
non-condensing @ 40°C)
according to EN62053-21
and EN62053-23
-30°C to +70°C (-22°F to
158°F) (R.H. < 90% non-
condensing @ 40°C)
according to EN62053-21
and EN62053-23
Cat. III (IEC60664,
EN60664)
4000 VRMS between mea-
suring inputs and power
supply.
4000 VRMS between power
supply and RS485 digital
outputs
10V/m from 150KHz to
80MHz
On current and voltage
measuring inputs circuit:
4kV;
Surge
Storage temperature
Radio frequency suppression According to CISPR 22
Standard compliance
Safety
IEC60664, IEC61010-1
EN60664, EN61010-1
EN62052-11
EN62053-21, EN50470-3,
EN62053-23.
DIN43864, IEC62053-31
CE, cULus listed, MID (PF
option only)
Installation category
Metrology
Insulation (for 1 minute)
Pulse output
Approvals
Connections
Cable cross-section area
Screw-type
Max. 1.5 mm2
Housing
Dimensions (WxHxD)
Material
Dielectric strength
Noise rejection CMRR
EMC
Electrostatic discharges
Immunity to irradiated
4000 VRMS for 1 minute
100 dB, 48 to 62 Hz
96 x 96 x 63 mm
ABS,
self-extinguishing: UL 94 V-0
Panel mounting
According to EN62052-11
15kV air discharge;
Test with current: 10V/m
from 80 to 2000MHz;
Test without any current:
30V/m from 80 to
Mounting
Protection degree
Front
Screw terminals
Weight
IP50
IP20
Electromagnetic fields
Approx. 400 g (packing
included)
2000MHz;
Burst
On current and voltage
measuring inputs circuit:
4kV
Power supply specifications
Auxiliary power supply
H: 90 to 260VAC/DC
(48 to 62Hz)
Power consumption
AC: 6VA
DC: 3.5 W
6
Specifications are subject to change without notice EM2696 DS ENG 061014
EM26 96
Accuracy (according to EN50470-3 and EN62053-23)
kWh, accuracy (RDG) depending on the current
kvarh, accuracy (RDG) depending on the current
Percentage error limits for class index B
+1.5%
+1%
+2,5%
+2%
0%
0%
-1%
-1,5%
-2%
-2,5%
PF=1 0.05A (Imin
)
0.25A (Itr)
0.25A (Itr)
5A (In)
5A (In)
10A (Imax
)
)
sinj=1
sinj=0.5
0.1A
0.25A
0.5A
5A (In)
5A (In)
10A (Imax
)
)
PF=L0.5
orC0.8
0.25A
10A (Imax
10A (Imax
Accuracy limits (Active energy)
Accuracy limits (Reactive energy)
Start-up current: 10mA
Start-up current: 10mA
MID „Annex MI-003‰ compliance (PF option only)
Accuracy
0.9 Un ≤ U ≤ 1.1 Un;
0.98 fn ≤ f ≤ 1.02 fn;
fn: 50Hz;
cosj: 0.5 inductive to 0.8
capacitive.
Class B. I st: 0.01A; I min:
0.05A; I tr:0.25A; I n: 5A;
I max: 10A
-25°C to +55°C (-13°F to
131°F) (R.H. from 0 to 90%
non-condensing @ 40°C)
EMC compliance
Mechanical compliance
Protection degree
E2
M2
in order to achieve the
protection against dust and
water required by the
norms harmonized to MID,
the meter must be used
only installed in IP51 (or
better) cabinets.
AV5-AV6 models
Operating temperature
Used calculation formulas
Phase variables
Systemvariables
Energy metering
Equivalent three-phase voltage
Three-phase reactive power
Three-phase active power
Three-phase apparent power
Instantaneous effective voltage
Instantaneous active power
Where:
P= active power;
Q= reactive power;
t1, t2 =starting and ending time points
of consumption recording;
nj= time unit;
Instantaneous power factor
PF
Instantaneous effective current
t= time interval between two succes-
sive power consumptions;
n1, n2 = starting and ending discrete
time points of consumption recording
Three-phase power factor
(TPF)
Instantaneous apparent power
Instantaneous reactive power
Where: n= sample number
Specifications are subject to change without notice EM2696 DS ENG 061014
7
EM26 96
List of the variables that can be connected to:
• RS485 communication port
• Alarm outputs (“max” variable”, “energies” and “hour counter” excluded)
• Pulse outputs (only positive “energies”)
No
Variable
1-phase 2-phase
3-ph. 4-wire 3-ph. 4-wire 3 ph. 3-wire 3 ph. 3-wire
Notes
system
system
balanced sys. unbal. sys.
bal. sys.
unbal. sys.
1
2
3
4
5
6
7
8
9
V L-N sys
V L1
V L2
x
x
x
o
x
x
o
o
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
sys=system
x
o
o
o
o
o
o
V L3
V L-L sys
V L1-2
V L2-3
V L3-1
A dmd max
sys=system
Highest “dmd”
current among
the phases (1)
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
A L1
A L2
A L3
VA sys
VAsysdmd
VA L1
VA L2
VA L3
var sys
var L1
var L2
var L3
W sys
Wsysdmd
W L1
W L2
W L3
PF sys
PF L1
PF L2
PF L3
Hz
Phase seq.
Hours
kWh(+)
kvarh(+)
kWh (+)
kvarh (+)
kWh (-)
kvarh (-)
m3 Gas
x
o
o
x
x
x
o
o
x
x
o
o
x
x
x
o
o
x
x
o
o
x
o
x
x
x
x
x
x
x
x
x
x
x
x
x
o
o
x
o
o
x
o
o
x
x
o
x
x
x
x
o
x
x
x
o
x
x
x
x
o
x
x
x
o
x
o
x
x
x
x
x
x
x
x
x
x
x
x
x
x
o
x
x
o
x
x
o
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
sys=system
sys=system (1)
sys=system
sys=system
sys=system (1)
Total or by user
Total or by user
Partial or by tariff
Partial or by tariff
Total
Total
Total
Total
Total
Total
Total
m3 ColdH
m3 Hot H
kWh H
kWh out
A L1 THD
A L2 THD
A L3 THD
V L1 THD
V L2 THD
V L3 THD
V L1-2 THD
V L2-3 THD
V L3-1 THD
2
O
2O
2
O
(x) = available; (o) = not available (zero indication on the display); (1) Max. value with data storage.
8
Specifications are subject to change without notice EM2696 DS ENG 061014
EM26 96
Display pages
Applications
1st variable
(1st line)
Total kWh (+)
kWh (+)
Total kvarh (+)
kvarh (+)
Totalizer 1 (2)
Totalizer 2 (2)
Totalizer 3 (2)
kWh (+)
kWh (+)
kWh (+)
kWh (+)
kvarh (+)
kvarh (+)
kvarh (+)
kvarh (+)
kWh (+) X
kWh (+) Y
kWh (+) Z
2nd variable
(2nd line)
W sys dmd W sys dmd max
A dmd max “PArt”
VA sys dmd VAsysdmdmax
3rd variable
(3rd line)
Sel.
No
pos.
Note
A
x
B
x
C
x
D
E
x
F
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
G
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
H
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
“PArt” = Partial kWh (+)
“PArt” = Partial kvarh (+)
x
x
VA sys
W sys
W sys
“PArt”
(text) (3)
(text) (3)
(1)
(1)
(1)
x
x
x
x
x
x
x
x
x
x
x
W sys
(text) (3)
t1 (text) (4)
t2 (text) (4)
t3 (text) (4)
t4 (text) (4)
t1 (text) (4)
t2 (text) (4)
t3 (text) (4)
t4 (text) (4)
W X
W sys dmd
W sys dmd
W sys dmd
W sys dmd
W sys dmd
W sys dmd
W sys dmd
W sys dmd
User X
(1) digital input enabled
(1) digital input enabled
(1) digital input enabled
(1) digital input enebled
(1) digital input enabled
(1) digital input enabled
(1) digital input enabled
(1) digital input enabled
(1) specific function enabled
(1) specific function enabled
(1) specific function enabled
x
x
x
W Y
W Z
User Y
User Z
19 Total kvarh (-)
VA sys dmd VAsysdmdmax
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
Total kWh (-)
Hours
W sys dmd
W sys
var sys
W L2
Wsysdmdmax
PF sys
PF sys
W L3
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Hours
W L1
VA L1
var L1
PF L1
V L1
V L1-2
A L1
VA L2
VA L3
var L2
PF L2
var L3
PF L3
V L2
V L3
x
x
x
x
V L2-3
A L2
V L3-1
A L3
x
x
Phase seq.
Phase seq.
ASY
V LN sys
V LL sys
V LL sys
V LN sys
THD A2
THD V2
THD V23
Year
Hz
Hz
%
%
x
x
x
x
x
x
ASY
THD A1
THD V1
THD V12
Lot number
CT ratio
VT/PT ratio
THD A3
THD V3
THD V 31
DMD time
System
Connection
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Value of CT
Value of VT
40 a Alarm 1 status Set-point value Variable type
41 a Alarm 2 status Set-point value Variable type
42 a Alarm 3 status Set-point value Variable type
40 b Pulse 1 status Output pulse
41 b Pulse 2 status Output pulse
42 b Pulse 3 status Output pulse
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
43
Serial port
Address
RS485 status
0
1
2
Selector position which can be linked to any of the variable combinations listed above (No. from 1 to 36)
Selector position which can be linked to any of the variable combinations listed above (No. from 1 to 36)
Selector position which can be linked to any of the variable combinations listed above (No. from 1 to 36)
Selector position which can be linked to any of the variable combinations listed above (No. from 1 to 36).
In this position the front LED blinks proportionally to the reactive energy (kvarh) being measured
3
(1) The page is available according to the enabled measurement. (2) m3 Gas, m3 Water, kWh remote heating, external kWh
counter. (3) Hot or Cold (water), gas, ENE (external energy meter). (4) The active tariff is displayed with an “A” before the “t1-
t2-t3-t4” simbols.
Specifications are subject to change without notice EM2696 DS ENG 061014
9
EM26 96
Additional available information on the display
Type
1st line
Firmware release
Pulse
2nd line
Year
3rd line
Year of production
Value
Meter information pag. 1
Meter information pag. 2
Meter information pag. 3
Meter information pag. 4
Meter information pag. 5
LED
System
2w, 3w or 4w
Value of CT ratio
Value of PT ratio
CT ratio
PT ratio
Alarm output 1, 2 or 3 status
In case of alarm output
pag.6a
Set-point value
Variable type
(ON/OFF)
In case of pulse output
pag. 6b
Pulse output 1,2 or 3 variable
Output pulse weight
(kWh/kvarh per pulse)
link (kWh/kvarh)
In case of communication
port pag.7
In case of communication
port pag.8
Serial port
Address
Sn
RS485 status (RX-TX)
Secondary address
(for M-bus protocol)
List of selectable applications
Description
Notes
A
B
Basic domestic **
Main energy metering
Main energy metering
Shopping centres **
Main energy metering (total and based on tariff), gas and
water metering
C
Advanced domestic**
Multi domestic (also camping and marinas) * / **
Solar *
D
E
F
Main energy metering (3 by single phase)
Energy meter with some basic power analyzer functions
Main energy metering
Industrial *
G
H
Advanced industrial **
Energy metering and power analysis
Advanced industrial for power generation *
Complete energy metering and power analysis
Notes: * Not available with option PF A. ** Not available with option PF B
Insulation between inputs and outputs
Relay
output
Open collector
outputs
Measuring Inputs
Comm. port
Digital inputs
Auxiliary power sup-
Measuring Inputs
Relay output
-
4kV
4kV
4kV
4kV
4kV
-
4kV
-
4kV
4kV
4kV
4kV
4kV
-
4kV
4kV
4kV
4kV
4kV
-
-
Open collector
outputs
-
-
-
Comm. port
4kV
-
4kV
-
4kV
-
Digital inputs
Aux. power sup-
4kV
4kV
4kV
4kV
4kV
NOTE: all the models with auxiliary power supply have, mandatory, to be connected to external current transformers
because the insulation among the current inputs is just functional (100VAC).
Tamper proof and display page selection
Lock of programming with seal.
Selection of up to 4 main pages
(programmable by the user).
Easy access to specific display pages.
10
Specifications are subject to change without notice EM2696 DS ENG 061014
EM26 96
Wiring diagrams
System type selection: 3P.n
3-ph, 4-wire, unbalanced load Fig. 2
3-ph, 4-wire, unbalanced load Fig. 1
3-CT connection
3-CT and 3-VT/PT connections
System type selection: 3P.n
3-ph, 3-wire, unbalanced load Fig. 5
3-ph, 3-wire, unbalanced load Fig. 3
3-ph, 3-wire, unbalanced load Fig. 4
3-CT connection
3-CT and 2-VT/PT connections
2-CT connections (ARON)
System type selection: 3P.1
3-ph, 3-wire, unbalanced load Fig. 6
3-ph, 3-wire, balanced load Fig. 7
3-ph, 3-wire, balanced load Fig. 8
1-CT connection
NOTE: a 2-wire connection for voltage measure-
ment is available across 15 and 17 .
2-CT and 2-VT/PT connections ARON
1-CT and 2-VT/PT connections
Specifications are subject to change without notice EM2696 DS ENG 061014
11
EM26 96
Wiring diagrams
System type selection: 2P
System type selection: 1P
2-ph, 3-wire
Fig. 9
2-ph, 3-wire
Fig. 10
1-ph, 2-wire
Fig. 11
2-CT connection
2-CT and 2-VT/PT connections
1-CT connection
System type selection: 1P
Auxiliary power supply wiring diagrams
1-ph, 2-wire
Fig. 12
100 to 230VAC/DC (“H” option) Fig.13
1-CT and 1-VT connections
F= 250V [T] 100mA
Digital inputs and RS485 port wiring diagrams
Digital Inputs
RS485 port
RS485 NOTE: additional devices provided with RS485 are connected in parallel. The termination of the serial output is car-
ried out only on the last instrument of the network, by means of a jumper between (A-) and (T).
12
Specifications are subject to change without notice EM2696 DS ENG 061014
EM26 96
Open collector and relay outputs wiring diagrams
Open Collector
Open Collector
Relay
1
2
3
1
2
3
GND reference
VDC reference
The load resistances (RC) must be designed so that the close contact current is lower than
100mA; the VDC voltage must be lower than or equal to 30VDC.
Front panel description
1. Display
LCD-type with alphanumeric indications to:
- display configuration parameters;
- display all the measured variables.
2. Selector
1
To select the desired display pages and to lock the
programming.
3. Joystick
To program the configuration parameters and scroll the
variables on the display.
4. LED
2
3
4
Red LED blinking proportionally to the energy being
measured.
Dimensions and Panel Cut-out
91mm
Specifications are subject to change without notice EM2696 DS ENG 061014