Proximity Sensors Inductive
Thermoplastic Polyester Housing
Types EI, DC, M12, M18, M30
• Euronorm thermoplastic polyester housing,
cylindrical
• Diameter: M12, M18, M30
• Flush and non-flush types
• Long and short body versions
• Sensing distance: 2 to 15 mm
• Power supply: 10 to 40 VDC
• Output: Transistor NPN/PNP, Normally open or Normaly
closed
• Protection: Short-circuit, reverse polarity and overload
• LED-indication for output ON
• 2 m cable or M12 plug
Product Description
Proximity switch in M12, M18 euronorms EN 50 008 and Type
and M30 polyester housings. EN 50 036.
Made in accordance with
Ordering Key
EI 1808 PPCPL-1
Housing diameter (mm)
Rated operating dist. (mm)
Output type
Housing material
Body style
Plug
Type Selection DC Types, Cable and M12 Plug
Housing
diameter
Body
style
Connection
Rated
operating
dist. (Sn)
Ordering no.
Transistor NPN
Normaly open
Ordering no.
Transistor PNP
Normaly open
Ordering no.
Transistor PNP
Normaly closed
M12
M12
M12
Long
Short
Long
Cable
Cable
Cable
2 mm 1)
4 mm 2)
4 mm 2)
EI 1202 NPOPL
EI 1204 NPOPL
EI 1202 PPOPL
EI 1204 PPOPS
EI 1204 PPOPL
M18
M18
M18
M18
M18
M18
Short
Long
Short
Short
Long
Long
Cable
Cable
Cable
Plug
Cable
Plug
5 mm 1)
5 mm 1)
8 mm2)
8 mm2)
8 mm2)
8 mm2)
EI 1805 PPOPS
EI 1805 PPOPL
EI 1808 PPOPS
EI 1808 PPOPS-1
EI 1808 PPOPL
EI 1805 NPOPL
EI 1808 NPOPS
EI 1808 NPOPL
EI 1808 PPCPL
EI 1808 PPOPL-1 EI 1808 PPCPL-1
M30
M30
M30
Long
Short
Long
Cable
Cable
Cable
10 mm 1)
15 mm 2)
15 mm 2)
EI 3010 NPOPL
EI 3015 NPOPS
EI 3010 PPOPL
EI 3010 PPCPL
EI 3015 PPOPL
1) For flush mounting in metal
2) For non-flush mounting in metal
Specifications
Rated operational volt. (Ue)
12 to 36 VDC
10 to 40 VDC (ripple incl.)
Frequency of operating cycles (f)
(UB)
EI 1202 800 Hz
EI 1204 500 Hz
EI 1805 500 Hz
EI 1808 400 Hz
EI 3010 300 Hz
EI 3015 100 Hz
Ripple
≤ 10%
Rated operational current (Ie)
Continuous
≤ 200 mA
Output ON: < 6.5 mA
Output OFF: < 2.7 mA
No-load supply current (Io)
Indication for output ON
Assured operating dist. (Sa)
Repeat accuracy (R)
Hysteresis (H) (Differential travel) 1 to 15% of sensing distance
Effective operating dist. (Sr)
Usable operating dist. (S)
LED, yellow
Voltage drop (Ud)
Protection
≤ 2 VDC at max. load
Reverse polarity, short-circuit,
transients
0 ≤ Sa ≤ 0.81 Sn
≤ 5%
Transient voltage
Power ON delay
≤ 700 V/0.5 J
< 10 ms
0.9 x Sn ≤ Sr ≤ 1.1 x Sn
0.9 x Sr ≤ Su ≤ 1.1 x Sr
Specifications are subject to change without notice (10.01.14)
1
EI, DC, M12, M18, M30
Specifications (cont.)
Ambient temperature
Operating
Storage
Weight (cable excluded)
-25° to +70°C (-13° to +158°F)
-30° to +80°C (-22° to +176°F)
EI12 10 g
EI 1805 18 g
EI 1808 20 g
EI 3010 50 g
EI 3015 70 g
Degree of protection
Housing material
Body
Back
IP 67 (Nema 1, 3, 4, 6, 13)
Grey thermoplastic polyester
Black polyester
Tightening torque
EI 12 1.8 Nm
EI 18 2.6 Nm
EI 30 7.5 Nm
Connection
Cable
2 m, 3 x 0.3 mm2, grey PVC,
oil proof
M 12 x 1
Approvals
CE-marking
EMC
UL, CSA
Yes
Plug
Cables for plug (-1)
CONH1A serie
Approved acc. to EN 50 080,
EN 50 081
Dimensions
Type
A
B (Ø mm) C (mm)
D (mm)
11
E (mm)
F (mm)
SW (mm)
EI 1202 XPXPL
EI 1204 XPXPS
EI 1204 XPXPL
M 12 x 1 x 50
M 12 x 1 x 30
M 12 x 1 x 50
10.7
10.7
10.7
50
34
54
5.0
5.0
5.0
8
8
8
17
17
17
11
11
EI 1805 XPXPS
EI 1805 XPXPL
EI 1808 XPXPS
EI 1808 XPXPL
EI 1808 XPXPL-1
M 18 x 1 x 30
M 18 x 1 x 50
M 18 x 1 x 30
M 18 x 1 x 50
M 18 x 1 x 50
16.7
16.7
16.7
16.7
16.7
30
50
38
58
58
11.6
11.6
11.6
11.6
13.1
15.4
15.4
15.4
15.4
11.9
8
8
8
8
8
24
24
24
24
24
EI 3010 XPXPL
EI 3015 XPXPS
EI 3015 XPXPL
M 30 x 1.5 x 50
M 30 x 1.5 x 30
M 30 x 1.5 x 50
28
28
28
50
42
62
13.6
13.6
13.6
15.4
15.4
15.4
10
10
10
36
36
36
C
D
E
C
D
E
M 12 x 1
F
F
SW
SW
A
LED
LED
A
Cable
Plug
Wiring Diagrams
+
+
-
1 BN
+
+
-
1 BN
1 BN
1 BN
4 BK
BK
2
BK
2
4 BK
3 BU
3 BU
3 BU
3 BU
-
-
NPN - Normally open
NPN - Normally closed
PNP - Normally open
PNP - Normally closed
2
Specifications are subject to change without notice (10.01.14)
EI, DC, M12, M18, M30
Installation Hints
To avoid interference from inductive voltage/
current peaks, separate the prox. switch
power cables from any other power cables,
e.g. motor, contactor or solenoid cables
Relief of cable strain
Protection of the sensing face
Switch mounted on mobile carrier
Incorrect
Correct
The cable should not be pulled
A proximity switch should not serve as
mechanical stop
Any repetitive flexing of the
cable should be avoided
Power Supplies
Power supplies VAC:
Power supplies VDC:
> SS 110.
> SS 130/140.
Power supplies with amplifier relays: > SV 190.
Specifications are subject to change without notice (10.01.14)
3
相关型号:
EI1808PPCPL-1
Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M12, M18, M30
CARLOGAVAZZI
EI1808PPCSL
Proximity Sensors Inductive Stainless Steel Housing Types EI, DC, M12, M18, M30
CARLOGAVAZZI
EI1808PPCSL-
Proximity Sensors Inductive Stainless Steel Housing Types EI, DC, M12, M18, M30
CARLOGAVAZZI
EI1808PPCSS
Proximity Sensors Inductive Stainless Steel Housing Types EI, DC, M12, M18, M30
CARLOGAVAZZI
EI1808PPCSS-
Proximity Sensors Inductive Stainless Steel Housing Types EI, DC, M12, M18, M30
CARLOGAVAZZI
EI1808PPOPL
Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M12, M18, M30
CARLOGAVAZZI
EI1808PPOPL-1
Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M12, M18, M30
CARLOGAVAZZI
EI1808PPOPS
Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M12, M18, M30
CARLOGAVAZZI
EI1808PPOPS-1
Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M12, M18, M30
CARLOGAVAZZI
EI1808PPOSL
Proximity Sensors Inductive Stainless Steel Housing Types EI, DC, M12, M18, M30
CARLOGAVAZZI
©2020 ICPDF网 联系我们和版权申明