55A1842-6 [BRTLED]
SPECIFICATION CONTROL DRAWING; 规格控制图型号: | 55A1842-6 |
厂家: | BRTLED |
描述: | SPECIFICATION CONTROL DRAWING |
文件: | 总1页 (文件大小:563K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
55A1842
SPECIFICATIONCONTROLDRAWING
Date
Revision
TITLE
FOUR CONDUCTORCABLE,RADIATION-CROSSLINKED,MODIFIEDETFEINSULATED,
02-26-04
B
SHIELDED,JACKETED,NORMALWEIGHT,600VOLT
This specification sheet forms a part of the latest issue of Raychem Specification 55A.
COMPONENTWIRE-55A0812
SHIELD-SILVER-COATEDCOPPER
JACKET-RADIATION-CROSSLINKED,
MODIFIED ETFE
CABLECONSTRUCTIONDETAILS
JACKETTHICKNESS
OUTSIDEDIAMETER
(inches)
MAXIMUM
WEIGHT
(lbs/1000 ft.)
CONDUCTOR SHIELD
(inches)
PARTNUMBER
SIZE
SIZE
1/
(AWG)
(AWG)
MINIMUM
NOMINAL
NOMINAL
MAXIMUM
38
38
38
38
38
38
38
38
36
34
34
34
.008
.008
.008
.008
.008
.009
.009
.009
.010
.011
.014
.018
.130
.142
.154
.173
.202
.221
.262
.304
.365
.520
.637
.812
.150
.165
.179
.202
.237
.259
.308
.357
.430
.613
.753
.960
14.7
18.0
22.5
30.0
42.2
51.4
74.0
104.
162.
305.
455.
743.
55A1842-26-*
55A1842-24-*
55A1842-22-*
55A1842-20-*
55A1842-18-*
55A1842-16-*
55A1842-14-*
55A1842-12-*
55A1842-10-*
55A1842- 8-*
55A1842- 6-*
55A1842- 4-*
.006
.006
.006
.006
.006
.007
.007
.007
.008
.009
.012
.016
26
24
22
20
18
16
14
12
10
8
6
4
CABLERATINGSANDADDITIONALREQUIREMENTS
TEMPERATURERATING: 200°C
LIFE CYCLE: 230 ± 3°C for 500 hours
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
ACCELERATED AGING: 300 ± 3°C for 7 hours
BLOCKING: 200 ± 3°C for 6 hours
DIELECTRIC WITHSTAND: 1500 volts (rms), 60 Hz
FLAMMABILITY: Procedure 1,
3 seconds (maximum); 3 in. (maximum);
no flaming of facial tissue
JACKET COLOR: White preferred
JACKETELONGATIONANDTENSILESTRENGTH:
Elongation, 50% (minimum)
LOW TEMPERATURE-COLD BEND: -65 ± 2°C for 4 hours
SHIELDCOVERAGE: 85%(minimum)
VOLTAGEWITHSTANDTEST(PostEnvironmental):
1000 volts (rms), 60 Hz, 1 minute
PARTNUMBER:
The "*" in the part numbers above shall be replaced
by color code designators with a slash separating
the component wire colors and a dash separating
the component wire colors from the jacket color.
Colors shown do not necessarily reflect the sequence of
manufacturing.
Tensile Strength, 5000 lbf/in² (minimum)
JACKETFLAWS:
Spark Test, 1000 volts (rms)
1/ Example: AWG 20, brown, red, orange and yellow
component wires; white jacket:
Impulse Dielectric Test, 6.0 kV (peak)
55A1842-20-1/2/3/4-9
NOTE: Nominal values are for information only.
Nominal values are not requirements.
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER,
AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: “901/902...” MAY BE REPLACED BY “Axxx”.) OTHER CODES AND
SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
R Wire & Cable
501OaksideAvenue
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL.
RedwoodCity,CA 94063-3800
Phone: 1-800-227-8816
Fax:1-650-361-6297
Page
1 of 1
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
相关型号:
©2020 ICPDF网 联系我们和版权申明