2410-31-N-MSP-ST [BOURNS]

2410 Series - 5-Pin Multi-Stage Protector (MSP®); 2410系列 - 5引脚多级保护( MSP® )
2410-31-N-MSP-ST
型号: 2410-31-N-MSP-ST
厂家: BOURNS ELECTRONIC SOLUTIONS    BOURNS ELECTRONIC SOLUTIONS
描述:

2410 Series - 5-Pin Multi-Stage Protector (MSP®)
2410系列 - 5引脚多级保护( MSP® )

文件: 总2页 (文件大小:140K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Features  
Patented Multi-stage protection (MSP®)  
Balanced TRIGARD®  
Meets test requirements of Telcordia  
GR 974, GR1361, SBC SR 5165 and  
RUS PE-80  
Telcordia Analysis report DA-1547  
Solid brass, gold-plated pins  
Test point access option  
Patented Switch-Grade Fail-Short Device  
Quick response and high energy handling  
Ideal for high-speed networks in high  
exposure environments  
Sealed option for harsh environments  
U
C
®
L
US LISTED  
per UL 497 (File: 53117)  
2410 Series - 5-Pin Multi-Stage Protector (MSP®)  
Bourns® 5-Pin Multi-Stage Protector (MSP®) is the latest generation telecommunications protector for high performance and long  
life in overvoltage protection of copper pair voice-band and high-speed data circuits. Bourns MSP® combines the advantages of gas  
tube and solid state protection while integrating three advanced technologies: a proprietary high-efficiency gas discharge tube,  
precision matched metal oxide varistors and a patented Switch-Grade Fail-Short mechanism. The Switch-Grade Fail-Short  
mechanism ensures superior thermal protection with fast acting, highly reliable response to thermal overload conditions. This  
combined technology provides lower capacitance, higher reliability and longer life than competitive hybrid technologies.  
Bourns® 2410 can be used universally for POTS and high speed data, e.g. ISDN, ADSL, ADSL2+, VDSL, VDSL2, other xDSL  
protocols and high speed Ethernet. Bourns® MSP® technology provides unparalleled overvoltage protection with low loss on paired  
copper communications circuits. The 2410 series is the most economical, reliable and effective choice for overvoltage protection of  
copper pair circuits.  
Characteristics  
Test Methods per UL 497, CSA C22.2, Telcordia GR 974, 1361 and SBC SR 5165.  
DC Breakdown ............................................................................................................................................... 300-400 V  
AC Breakdown @ 60 Hz ................................................................................................................................. 300-400 V  
Impulse Breakdown  
100 V/µs .................................................................................................................................................... 600 V  
1000 V/µs .................................................................................................................................................. 650 V  
Insulation Resistance @ 100 Vdc ................................................................................................................... >1 GΩ  
Insertion Loss @ 100 MHz.............................................................................................................................. <0.4 dB1  
Return Loss @ 100 MHz................................................................................................................................. >14 dB1  
Capacitance Tip to Ring @ 1 MHz ................................................................................................................. 10 pF typical  
Capacitance Tip or Ring to Ground @ 1 MHz................................................................................................ 20 pF typical  
Impulse Reset 5  
52 V, 260 mA ............................................................................................................................................. <10 ms  
135 V, 200 mA ........................................................................................................................................... <10 ms  
150 V, 200 mA ........................................................................................................................................... <150 ms  
Impulse Life Characteristics (Tip and Ring to Ground Simultaneously)  
10 to 100 A, 10/1000 µs............................................................................................................................ >3000 operations2  
300 A, 10/1000 µs ..................................................................................................................................... >1000 operations2  
500 A, 10/1000 µs ..................................................................................................................................... >1000 operations4  
2,000 A, 10/250 µs .................................................................................................................................... >100 operations2  
5,000 A, 20/100 µs .................................................................................................................................... >10 operations2  
20,000 A, 8/20 µs ...................................................................................................................................... >10 operations4  
AC Life Characteristics (Tip and Ring to Ground Simultaneously)  
0.5 A rms continuous ................................................................................................................................ >30 seconds  
1 A rms, 1 second, 600 ft. cable ............................................................................................................... >60 seconds  
1 A rms, 1 second, 1 mile cable................................................................................................................ >60 operations  
10 A rms, 1 second ................................................................................................................................... >5 operations  
65 A rms, 11 cycles................................................................................................................................... >1 operation3  
120 A rms, 0.1 second .............................................................................................................................. 1 operation  
High Current Capability and Thermal Operation (Tip and Ring to Ground,  
Vented or Non-Vented Gas Tube)................................................................................................................... >30 A rms, simultaneously  
Storage and Operating Temperature.............................................................................................................. -55 to +85 °C  
Telcordia analyzed for controlled (non-sealed) and uncontrolled, high-exposure (sealed) environments per GR 974 and SBC SR 5165.  
Telcordia Technical Analysis Report DA-1547.  
Notes:  
1
Tested according to Category 5 requirements  
Exceeds Telcordia (Bellcore) GR 1361  
Surpasses Telcordia GR 974  
RUS (REA) PE-80  
2
3
4
5
Network applied  
Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.  
Specifications are subject to change without notice.  
Customers should verify actual device performance in their specific applications  
2410 Series - 5-Pin Multi-Stage Protector (MSP®)  
How To Order  
2410 - X XX - X - XXX - XX  
Model Number Designator  
Module Length  
3 = Standard: 52.37 mm (2.06 in.) 7 = Special Short: 41.19 mm (1.62 in.)  
Housing Color/Circuit Type  
1 = Black/Standard  
3 = Red/Special  
6 = Blue/Standard  
9 = Orange/Standard Service (non-Bridgelifter)  
10 = Yellow/Standard  
Pin Plating  
G = Gold Plated  
N = Tin Plated  
Protector Type  
MSP® = Multi-Stage Protector  
BC = Balanced Capacitance*  
ST = Sealed Case and Test Points**  
Special Options  
S = Sealed Case  
T = Test Points**  
*For use on DSL Systems that require balanced capacitance of 1 pF.  
**T and ST options are not available on 2410-7x short module.  
Product Dimensions  
2410-3 MODULE  
42.17  
(1.66)  
12.8  
(0.50)  
29.9  
(1.18)  
5.7  
(0.223)  
2.3  
(.092)  
2.2  
(.085)  
DIA.  
5 PLCS.  
DIA.  
2 PLCS.  
19.0  
(0.75)  
5.6  
(0.220)  
11.2  
(0.440)  
11.2  
(0.44)  
5.1  
(0.20)  
6.1  
(0.240)  
3.6  
(0.14)  
10.2  
(0.40)  
2410-7 MODULE  
30.99  
(1.22)  
MM  
(INCHES)  
DIMENSIONS:  
24.9  
Asia-Pacific:  
Tel: +886-2 2562-4117  
(0.98)  
6.15  
(0.24)  
Fax: +886-2 2562-4116  
Europe:  
Tel: +41-41 768 5555  
Fax: +41-41 768 5510  
The Americas:  
Tel: +1-951 781-5500  
Fax: +1-951 781-5700  
5.1  
(0.20)  
www.bourns.com  
10.2  
(0.40)  
REV. N 09/15/09  
“MSP” and “TRIGARD” are registered trademarks of Bourns, Inc.  
Specifications are subject to change without notice.  
Customers should verify actual device performance in their specific applications  

相关型号:

2410-31-N-MSP-T

2410 Series - 5-Pin Multi-Stage Protector (MSP®)
BOURNS

2410-310-G-BC-S

2410 Series - 5-Pin Multi-Stage Protector (MSP®)
BOURNS

2410-310-G-BC-ST

2410 Series - 5-Pin Multi-Stage Protector (MSP®)
BOURNS

2410-310-G-BC-T

2410 Series - 5-Pin Multi-Stage Protector (MSP®)
BOURNS

2410-310-G-MSP-S

2410 Series - 5-Pin Multi-Stage Protector (MSP®)
BOURNS

2410-310-G-MSP-ST

2410 Series - 5-Pin Multi-Stage Protector (MSP®)
BOURNS

2410-310-G-MSP-T

2410 Series - 5-Pin Multi-Stage Protector (MSP®)
BOURNS

2410-310-N-BC-S

2410 Series - 5-Pin Multi-Stage Protector (MSP®)
BOURNS

2410-310-N-BC-ST

2410 Series - 5-Pin Multi-Stage Protector (MSP®)
BOURNS

2410-310-N-BC-T

2410 Series - 5-Pin Multi-Stage Protector (MSP®)
BOURNS

2410-310-N-MSP-S

2410 Series - 5-Pin Multi-Stage Protector (MSP®)
BOURNS

2410-310-N-MSP-ST

2410 Series - 5-Pin Multi-Stage Protector (MSP®)
BOURNS