2036-30SM-RP3LF [BOURNS]

Surge Protection Circuit, ROHS COMPLIANT PACKAGE;
2036-30SM-RP3LF
型号: 2036-30SM-RP3LF
厂家: BOURNS ELECTRONIC SOLUTIONS    BOURNS ELECTRONIC SOLUTIONS
描述:

Surge Protection Circuit, ROHS COMPLIANT PACKAGE

电信 电信集成电路
文件: 总3页 (文件大小:252K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Features  
Balanced Mini-TRIGARD™ Series  
High surge current rating, low insertion loss  
UL Recognized  
RoHS compliant* version available  
(5 mm diameter, 7.3 mm length)  
Ideal for board level protection of  
broadband circuits  
Leadless, surface mount for economical  
assembly  
Stable breakdown throughout life  
2036-xx-SM Precision Gas Discharge Tube Surge Protector  
Bourns now offers a surface mount (SM) 3-electrode Gas Discharge Tube (GDT) surge protection device. The industry-leading quality  
and features of the Bourns® miniature 2036 TRIGARD™ series GDT continues in this new SM version for “pick and place”  
manufacturing techniques. The 2036 SM device is ideal for board level protection of high bandwidth applications such as xDSL,  
cable broadband and high speed Ethernet, due to its high energy handling capability, long and stable life performance and low  
capacitance of less than 2 pF. Bourns subminiature family of GDTs measure only 5 mm in diameter and are the smallest high  
performance GDTs in the telecom industry. Bourns® GDTs are designed to prevent damage from transient disturbances by acting as  
a “crowbar” in creating a short-to-ground circuit during conduction. When a voltage transient surge exceeds the defined breakdown  
voltage level of the GDT, the device becomes ionized and conduction takes place within a fraction of a microsecond. When the surge  
passes and system voltage returns to normal levels, the GDT returns to its high-impedance (off) state.  
Characteristics  
Test Methods per ITU-T (CCITT) K.12, IEEE C62.31  
Model No.  
Characteristic  
2036-07  
2036-09  
2036-15  
2036-20  
2036-23  
2036-25  
DC Sparkover 20 ꢀ ꢁ 100 V/s  
Impulse Sparkover  
100 V/µs  
75 V  
90 V  
150 V  
200 V  
230 V  
250 V  
250 V  
525 V  
250 V  
550 V  
350 V  
500 V  
425 V  
575 V  
450 V  
600 V  
475 V  
625 V  
1000 V/µs  
Model No.  
Characteristic  
2036-30  
2036-35  
2036-40  
2036-42  
2036-47  
2036-60  
DC Sparkover 20 ꢀ ꢁ 100 V/s  
Impulse Sparkover  
100 V/µs  
300 V  
350 V  
400 V  
420 V  
470 V  
600 V  
500 V  
650 V  
600 V  
750 V  
650 V  
825 V  
675 V  
850 V  
750 V  
950 V  
850 V  
1100 V  
1000 V/µs  
Impulse Transverse Delay................................ 100 V/μs............................................................< 75 ns  
10  
Insulation Resistance (IR)................................ 100 V (50 V for Model 2036-07 & 2036-09) ......> 10  
Glow Voltage ................................................... 10 mA................................................................~ 70 V  
Arc Voltage ...................................................... 1 A.....................................................................~ 10 V  
Glow-Arc Transition Current.......................................................................................................< 0.5 A  
Capacitance .................................................... 1 MHz ...............................................................< 2 pF  
Ω
1
DC Holdover Voltage .................................... >135 V, (52 V for Model 2036-07, & -09, ..........< 150 ms  
......................................................................... 80 V for Model 2036-15)  
2
Impulse Discharge Current.............................. 20000 A, 8/20 µs ............................................. 1 operation minimum  
10000 A, 8/20 µs...............................................> 10 operations  
200 A, 10/1000 µs ............................................> 300 operations  
2000 A, 10/350 µs............................................. 1 operation  
200 A, 10/700 µs ..............................................> 500 operations  
2
Alternating Discharge Current......................... 20 Arms, 1 s .................................................... 1 operation minimum  
10 Arms, 1 s......................................................> 10 operations  
Operating Temperature............................................................................................................... -55 to +85 °C  
Climatic Category (IEC 60068-1)................................................................................................ 40/90/21  
Notes:  
• UL Recognized component, UL File E153537.  
• No model number marking on tube; date code and voltage only: month year digits, xxxV (e.g. 0209 400V).  
• The rated discharge current for Mini-TRIGARD™ GDTs is the total current equally divided between each line to ground.  
• Surface Mount (SM) parts may show a temporary increase in DCBD after the solder reflow process. Most devices will recover  
within 24 hours time. It should be noted that there is no quality defect nor change in protection levels during the temporary  
change in DCBD.  
8
• Sparkover limits after life 25 ꢀ (-25 ꢀ,+30 ꢀ for Model 2036-07, 2036-09 and 2036-60), IR >10 Ω.  
• Operating characteristics per RUS PE-80 and Telcordia GR 1361 available on request.  
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.  
• At delivery AQL 0.65 Level II, DIN ISO 2859.  
1
Network applied.  
*RoHS Directive 2002/95/EC Jan 27, 2003 including Annex.  
Specifications are subject to change without notice.  
Customers should verify actual device performance in their specific applications.  
2036-xx-SM Precision Gas Discharge Tube Surge Protector  
Product Dimensions  
Recommended Pad Layout  
7.3  
1.6  
5.6  
0.9  
5.0 DIA.  
5.0  
0.7  
4.8 DIA.  
0.5  
3.3  
8.ꢀ  
DIMENSIONS: MILLIMETERS  
DIMENSION TOLERANCE: .X 0.ꢀ5  
How to Order  
2036 - xx - SM - RP LF  
Model Number Designator  
Voltage (Divided by 10)  
Surface Mount  
Packaging Options*  
Blank = Bulk Packaging (Standard)  
RP = Reelpack - 1000 pcs./reel (Optional)  
RP2 = Reelpack - 1000 pcs./reel (Optional)  
Lead Free Option  
Blank = Standard Product  
LF = Lead Free / RoHS Compliant Product  
* The optional -RP & -RP2 reelpacks contain 1000 pcs./reel.  
The reels are 330 mm in diameter. The -RP reelpack is 18 mm wide.  
The -RP2 reelpack is 26 mm wide.  
Specifications are subject to change without notice.  
Customers should verify actual device performance in their specific applications.  
2036-xx-SM Precision Gas Discharge Tube Surge Protector  
Packaging Specifications  
The Model 2036-xx-SM ships standard bulk pack, 100 pieces per bag.  
The optional -RP & -RP2 reelpacks contain 1,000 pcs./reel. The reels are 330 mm in diameter. The -RP reelpack is 18 mm wide.  
The -RP2 reelpack is 26 mm wide.  
-RP  
4.0  
1.7  
2.0  
16.0  
7.5  
12.0  
-RP2  
4.0  
12.0  
1.75  
1.50 DIA.  
2.0  
A
11.50  
24.00  
3 °  
22.25  
4.35 0.10  
7.85 0.10  
14.90 0.10  
A
1.50  
DIA.  
3.15 0.10  
5.70 0.10  
.41  
3 °  
9.35 0.10  
SECTION A-A  
5.50 0.10  
DIMENSIONS: MILLIMETERS  
DIMENSION TOLERANCE: .X ±±.ꢀ2  
REV. M 01/11  
Mini-TRIGARD™ is a trademark of Bourns, Inc.  
Specifications are subject to change without notice.  
Customers should verify actual device performance in their specific applications.  

相关型号:

2036-30SMLF

暂无描述
BOURNS

2036-35

Precision Gas Discharge Tube Surge Protector
BOURNS

2036-35-A

2036 Series - Miniature 3-Pole Gas Discharge Tube
BOURNS

2036-35-AF

2036 Series - Miniature 3-Pole Gas Discharge Tube
BOURNS

2036-35-AFLF

Balanced Mini-TRIGARD 5 mm diameter, 7.5 mm long
BOURNS

2036-35-ALF

2036 Series - Miniature 3-Pole Gas Discharge Tube
BOURNS

2036-35-B

2036 Series - Miniature 3-Pole Gas Discharge Tube
BOURNS

2036-35-B2-F

TELECOM, SURGE PROTECTION CIRCUIT, XSS3, PACKAGE-3
BOURNS

2036-35-B2-FLF

TELECOM, SURGE PROTECTION CIRCUIT, XSS3, ROHS COMPLIANT, PACKAGE-3
BOURNS

2036-35-B2F

Surge Protection Circuit, PACKAGE-3
BOURNS

2036-35-B2FLF

Surge Protection Circuit, ROHS COMPLIANT PACKAGE-3
BOURNS

2036-35-B2LF

Surge Protection Circuit, ROHS COMPLIANT, PACKAGE-3
BOURNS