KA79L24A [BOCA]
3-TERMINAL 0.1A NEGATIVE VOLTAGE REGULATOR; 三端0.1A负稳压器型号: | KA79L24A |
厂家: | BOCA SEMICONDUCTOR CORPORATION |
描述: | 3-TERMINAL 0.1A NEGATIVE VOLTAGE REGULATOR |
文件: | 总12页 (文件大小:76K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
KA79LXXA
3-Terminal 0.1A Negative Voltage Regulator
Boca Semiconductor Corp.
BSC
http://www.bocasemi.com
Features
Description
• Output current up to 100mA
• No external components
These regulators employ internal current limiting and ther-
mal shutdown, making them essentially indestructible.
• Internal thermal over load protection
• Internal short circuit current limiting
• Output Voltage Offered in ± 5% Tolerance
• Output Voltage of -5V, -8V, -12V, -15V, -18V
and -24V
TO-92
SOT-89
1
1
1.GND 2.Input 3.Output
8-SOP
1
1. Output 2.3.6.7. GND 4.5. NC 8. Input
Internal Block Diagram
Output
Input
http://www.bocasemi.com
KA79LXXA
Absolute Maximum Ratings
Parameter
Symbol
Value
Unit
Input Voltage (for V = -5V to -8V)
-30
-35
-40
o
(for V = -12V to -18V)
V
I
V
o
(for V = -24V)
o
Operating Temperature Range
Storage Temperature Range
T
0 ~ +125
°C
°C
OPR
T
-65 ~ +150
STG
Electrical Characteristics(KA79L05A)
(V = -10V, I = 40mA, C = 0.33µF, C = 0.1µF, 0°C ≤T ≤ +125°C, unless otherwise specified)
I
O
I
O
J
Parameter
Symbol
Conditions
Min. Typ. Max. Unit
Output Voltage
V
T = +25 °C
J
- 4.8 - 5.0 - 5.2
V
O
Line Regulation (Note1)
-7.0V ≥ V ≥-20V
-
-
15
-
150
100
mV
I
∆V
∆V
T =+25 °C
J
O
O
-8V ≥ V ≥-20V
mV
mV
I
1.0mA ≤ I
≤
O
-
-
20
60
100mA
Load Regulation (Note1)
T =+25 °C
J
1.0mA ≤ I ≤ 40mA
10
30
- 5.25
- 5.25
5.5
mV
V
O
-7.0V ≥ V ≥ -20V, 1.0mA ≤ I ≤ 40mA - 4.75
-
-
I
O
Output Voltage
V
O
V = -10V, 1.0mA≤ I ≤70mA
- 4.75
V
I
O
T =+ 25 °C
J
-
-
-
-
-
2.0
-
Quiescent Current
I
mA
Q
T = +125 °C
J
6.0
with line
with load
∆I
∆I
-8V≥ V ≥-20V
-
1.5
mA
mA
µV
Q
I
Quiescent Current
Change
1.0mA≤ I ≤40mA
-
0.1
Q
N
O
Output Noise Voltage
Ripple Rejection
Dropout Voltage
V
T = +25°C,10Hz≤f≤100KHz
30
-
A
f = 120Hz, -8V≥V ≥-18V
I
RR
41
-
60
-
-
dB
V
T = +25°C
J
V
T = +25°C
J
1.7
D
Note
1. Load and line regulation are specified at constant junction temperature. Change in V due to heating effects must be taken
O
into account separately. Pulse testing with low duty is used.
2
KA79LXXA
Electrical Characteristics (KA79L08A)
(V = -14V, I = 40mA, C = 0.33µF, C = 0.1µF, 0°C ≤T ≤ +125°C, unless otherwise specified)
I
O
I
O
J
Parameter
Symbol
Conditions
Min. Typ. Max. Unit
Output Voltage
V
T = +25 °C
J
- 7.7 - 8.0 - 8.3
V
O
Line Regulation (Note1)
-10.3V ≥ V ≥ -23V
-
-
-
-
175 mV
125 mV
I
∆V
∆V
T =+25 °C
J
O
O
-12V ≥ V ≥ -23V
I
1.0mA ≤ I ≤ 100mA
-
-
-
80
40
mV
mV
o
Load Regulation (Note1)
Output Voltage
T =+25 °C
J
1.0mA ≤ I ≤ 40mA
-
o
-10.3V ≥ V ≥ -23V, 1.0mA ≤ I ≤ 40mA
- 7.6
-
- 8.4
- 8.4
6.0
5.5
1.5
0.1
-
I
o
V
V
O
V = -14V, 1.0mA ≤ I ≤ 70mA
- 7.6
-
I
o
T =+ 25 °C
j
-
-
-
-
-
-
Quiescent Current
I
mA
Q
T = +125 °C
j
-
with line
with load
-11.7V ≥ V ≥ -23V
-
mA
mA
µV
I
Quiescent Current
Change
∆I
Q
1.0mA ≤ I ≤ 40mA
-
o
Output Noise Voltage
Ripple Rejection
Dropout Voltage
V
T = +25°C,10Hz ≤ f ≤ 100KHz
50
N
j
f = 120Hz, -11V ≥ V ≥ -21V
I
RR
39
-
55
-
-
dB
V
T = +25°C
j
V
T = +25°C
j
1.7
D
Note
1. Load and line regulation are specified at constant junction temperature. Change in V due to heating effects must be taken
O
into account separately. Pulse testing with low duty is used.
3
KA79LXXA
Electrical Characteristics(KA79L12A)
(V = -19V, I = 40mA, C = 0.33µF, C = 0.1µF, 0°C ≤T ≤ +125°C, unless otherwise specified)
I
O
I
O
J
Parameter
Symbol
Conditions
Min. Typ. Max. Unit
Output Voltage
V
T = +25 °C
J
-11.5 -12.0 -12.5
V
O
Line Regulation (Note1)
-14.5V ≥V ≥-27V
-
-
-
-
250
200
mV
I
∆V
∆V
T = +25 °C
J
O
O
-16V≥V ≥-27V
mV
I
1.0mA≤ I ≤100mA
-
-
-
-
100
50
mV
mV
V
O
Load Regulation (Note1)
Output Voltage
T = +25 °C
J
1.0mA≤ I ≤40mA
O
-14.5V >V > -27V, 1.0mA ≤I ≤ 40mA -11.4
-
-12.6
-12.6
6.0
6.5
1.5
0.1
-
I
O
V
O
V = -19V, 1.0mA ≤ I ≤ 70mA
-11.4
-
V
I
O
T = +25 °C
J
-
-
-
-
-
-
Quiescent Current
I
mA
Q
T = +125 °C
J
-
with line
with load
∆I
∆I
-16V ≥ V ≥ -27V
-
mA
mA
µV
Q
I
Quiescent Current
Change
1.0mA ≤ I ≤ 40mA
-
Q
N
O
Output Noise Voltage
Ripple Rejection
Dropout Voltage
V
T = +25°C,10Hz ≤ f ≤ 100KHz
80
A
f = 120Hz, -15V ≥ V ≥ -25V
I
RR
37
-
42
-
-
dB
V
T = +25°C
J
V
T = +25°C
J
1.7
D
Note
1. Load and line regulation are specified at constant junction temperature. Change in V due to heating effects must be taken
O
into account separately. Pulse testing with low duty is used.
4
KA79LXXA
Electrical Characteristics(KA79L15A)
(V = -23V, I = 40mA, C = 0.33µF, C = 0.1µF, 0°C ≤T ≤ +125°C, unless otherwise specified)
I
O
I
O
J
Parameter
Symbol
Conditions
Min. Typ. Max. Unit
Output Voltage
V
T = +25 °C
J
-14.4 -15.0 -15.6
V
O
Line Regulation (Note1)
-17.5V ≥ V ≥ -30V
-
-
-
-
300
250
mV
I
∆V
∆V
T = +25 °C
J
O
-20V ≥ V ≥ -30V
mV
I
1.0mA ≤ I ≤ 100mA
-
-
-
150
75
mV
mV
V
O
Load Regulation (Note1)
Output Voltage
T = +25 °C
J
O
1.0mA ≤ I ≤ 40mA
-
O
-17.5V ≥ V ≥ -30V, 1.0mA ≤ I ≤ 40mA
-14.25
-
-15.75
-15.75
6.0
I
O
V
O
V = -23V, 1.0mA ≤ I ≤ 70mA
-14.25
-
V
I
O
T = +25°C
J
-
-
-
-
-
-
Quiescent Current
I
mA
Q
T = +125°C
J
-
6.5
with line
∆I
∆I
-20V ≥ V ≥ -30V
-
1.5
mA
mA
µV
Q
I
QuiescentCurrent
Change
with load
1.0mA ≤ I ≤ 40mA
-
0.1
Q
N
O
Output Noise Voltage
Ripple Rejection
Dropout Voltage
V
T = +25°C,10Hz ≤ f ≤ 100KHz
90
-
A
f = 120Hz, -18.5V ≥ V ≥ -28.5V
I
RR
34
-
39
-
-
dB
V
T = +25°C
J
V
T = +25°C
J
1.7
D
Note
1. Load and line regulation are specified at constant junction temperature. Change in V due to heating effects must be taken
O
into account separately. Pulse testing with low duty is used.
5
KA79LXXA
Electrical Characteristics(KA79L18A)
(V = -27V, I = 40mA, C = 0.33µF, C = 0.1µF, 0°C ≤T ≤ +125°C, unless otherwise specified)
I
O
I
O
J
Parameter
Symbol
Conditions
Min. Typ. Max. Unit
Output Voltage
V
T = +25 °C
J
-17.3 -18.0 -18.7
V
O
Line Regulation (Note1)
-20.7V ≥ V ≥ -33V
-
-
-
-
325
275
mV
I
∆V
∆V
T = +25 °C
J
O
O
-21V ≥ V ≥ -33V
mV
I
1.0mA ≤ I ≤ 100mA
-
-
-
170
85
mV
mV
V
O
Load Regulation (Note1)
Output Voltage
T = +25 °C
J
1.0mA ≤ I ≤ 40mA
-
O
-20.7V > V > -33V, 1.0mA ≤ I ≤ 40mA -17.1
-
-18.9
-18.9
6.5
6.0
1.5
0.1
-
I
O
V
O
V = -27V, 1.0mA ≤ I ≤ 70mA
-17.1
-
V
I
O
T = +25°C
J
-
-
-
-
-
-
Quiescent Current
I
mA
Q
T = +125°C
J
-
with line
with load
∆I
∆I
-21V ≥ V ≥ -33V
-
-
mA
mA
µV
Q
I
Quiescent Current
Change
1.0mA ≤ I ≤ 40mA
Q
N
O
Output Noise Voltage
Ripple Rejection
Dropout Voltage
V
T =+25°C,10Hz ≤ f ≤ 100KHz
150
A
f = 120Hz, -23V ≥ V ≥ -33V
I
RR
33
-
48
-
-
dB
V
T = +25°C
J
V
T = +25°C
J
1.7
D
Note
1. Load and line regulation are specified at constant junction temperature. Change in V due to heating effects must be taken
O
into account separately. Pulse testing with low duty is used.
6
KA79LXXA
Electrical Characteristics(KA79L24A)
(V = -33V, I = 40mA, C = 0.33µF, C = 0.1µF, 0°C ≤T ≤ +125°C, unless otherwise specified)
I
O
I
O
J
Parameter
Symbol
Conditions
Min. Typ. Max. Unit
Output Voltage
V
T = +25 °C
J
-23
-
-24
-
-25
V
O
Line Regulation (Note1)
-27V ≥ V ≥ -38V
350
mV
I
∆V
∆V
T = +25 °C
J
O
O
-28V ≥ V ≥ -38V
-
-
300
mV
I
1.0mA ≤ I ≤100mA
-
-
-
200
100
-25.2
-25.2
6.5
mV
mV
V
O
Load Regulation (Note1)
Output Voltage
T = +25 °C
J
1.0mA ≤ I ≤ 40mA
-
O
-27V ≥ V ≥ -38V, 1.0mA ≤ I ≤ 40mA -22.8
-
I
O
V
O
V = -33V, 1.0mA ≤ I ≤ 70mA
I
-22.8
-
V
O
T = +25°C
J
-
-
-
-
-
-
Quiescent Current
I
mA
Q
T = +125°C
J
-
6.0
with line
with load
∆I
∆I
-28V ≥ V ≥ -38V
-
-
1.5
mA
mA
µV
Q
I
Quiescent Current
Change
1.0mA ≤ I ≤ 40mA
0.1
Q
N
O
Output Noise Voltage
Ripple Rejection
Dropout Voltage
V
T = +25°C,10Hz ≤ f ≤100KHz
A
200
-
f = 120Hz, -29V ≥ V ≥ -35V
T = +25°C
J
I
RR
31
-
47
-
-
dB
V
V
T = +25°C
J
1.7
D
Note
1. Load and line regulation are specified at constant junction temperature. Change in V due to heating effects must be taken
O
into account separately. Pulse testing with low duty is used.
7
KA79LXXA
Typical Application
Design Considerations
The KA79LXXA Series of fixed voltage regulators are designed with Thermal Overload Protection that shuts down the circuit
when subjected to an excessive power overload condition. Internal Short Circuit Protection that limits the maximum current
the circuit will pass. In many low current applications, compensation capacitors are not required. However, it is recommended
that the regulator input be bypassed with a capacitor if the regulator is connected to the power supply filter with long wire
lengths, or if the output load capacitance is large. An input bypass capacitor should be selected to provide good high frequency
characteristics to insure stable operation under all load conditions. A 0.33µF or larger tantalum, mylar, or other capacitor hav-
ing low internal impedance at high frequencies should be chosen. The bypass capacitor should be mounted with the shortest
possible leads directly across the regulator's input terminals. Normally good construction techniques should be used to mini-
mize ground loops and lead resistance drops since the regulator has no external sense lead. Bypassing the output is also recom-
mended.
I
Figure 1. Positive And Negative Regulator
Figure 2. Typical Application
A common ground is required between the input and the output voltages. The input voltage must remain typically 2.0V above
the output voltage even during the low point on the input ripple voltage.
* C is required if regulator is located an appreciable distance from power supply filter.
1
* C improves stability and transient response.
O
8
KA79LXXA
Mechanical Dimensions
Package
TO-92
+0.25
–0.15
4.58
0.46 ±0.10
+0.10
–0.05
1.27TYP
1.27TYP
0.38
[1.27 ±0.20
]
[1.27 ±0.20]
3.60 ±0.20
(R2.29)
9
KA79LXXA
Mechanical Dimensions(Continued)
Package
8-SOP
0.1~0.25
0.004~0.001
MIN
1.55 ±0.20
0.061 ±0.008
#8
#5
#1
#4
6.00 ±0.30
0.236 ±0.012
1.80
0.071
MAX
3.95 ±0.20
0.156 ±0.008
5.72
0.225
0.50 ±0.20
0.020 ±0.008
10
KA79LXXA
Mechanical Dimensions (Continued)
Package
SOT-89
1.50 ±0.20
4.50 ±0.20
1.65 ±0.10
(0.40)
C0.2
0.50 ±0.10
0.40 ±0.10
+0.10
–0.05
0.40
1.50 TYP 1.50 TYP
11
KA79LXXA
Ordering Information
Product Number
KA79L05AZ
KA79L08AZ
KA79L12AZ
KA79L15AZ
KA79L18AZ
KA79L24AZ
KA79L05AD
KA79L05AM
Package
Operating Temperature
TO-92
0 ~ + 125°C
8-SOP
SOT-89
12
http://www.bocasemi.com
相关型号:
©2020 ICPDF网 联系我们和版权申明