XWS6012 [BEL]
DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid;型号: | XWS6012 |
厂家: | BEL FUSE INC. |
描述: | DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid |
文件: | 总3页 (文件大小:80K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
XWS DC-DC Series Data Sheet
100 to 192 Watts
Features
• High power package
• Wide input range
• Trim and enable pins
• Remote sense pins
• 500V isolation
Description
XWS dc-dc converters are high-powered converters which cover a wide range of industrial and general applications.
Available input voltages include 12V, 24V, 40V, and 48V; output voltages are available from 5V to 24V. The XWS
features remote sense leads for accurate point of load regulation. For dual and triple output high power solutions, see
the XWD and XWT Series of converters, respectively.
Efficiency vs. Load (24V Input)
95
Technical Specifications
Input
90
Voltage Range
12 VDC Nominal
24 VDC Nominal
40 VDC Nominal (Wide Input)
48 VDC Nominal
Input Ripple Current
Reverse Input Current
10 - 20 VDC
18 - 36 VDC
20 - 60 VDC
36 - 72 VDC
85
80
75
XWS2415
20% I Max.
in
100% I Max.
in
10
20
30
40
50
60
70
80
90 100
LOAD %
Efficiency vs. Load (48V Input)
Output
95
90
85
80
75
70
65
Setpoint Accuracy
±1%
Line Regulation V Min. - V Max., I
Rated
±0.2% V
±1% V
in
in
out
out
Load Regulation I
Min. - I
Max., V Nom.
out
out
in
out
Minimum Output Current
10 % l
rated
out
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
Voltage Trim Range
25% I
out
4% Vo
500 μs
±10%
XWS4805
XWS4815
10
20
30
40
50
60
70
80
90 100
LOAD %
General
Turn-On Time
10 ms
Notes
Remote Shutdown
Switching Frequency
Isolation
TTL And CMOS Compatible, Positive Logic
200 kHz
†
MTBF predictions may vary slightly from model to model.
Industrial temp range available
††
Input - Output
500 VDC
Temperature Coefficient
Case Temperature
Operating Range
±0.02%/°C
Specifications typically at 25°C, normal line, and full load, unless otherwise
stated.
-25 To +85°C††
-40 To +125°C
105 To 115°C
95%
5 g, 10 - 55 Hz
Consult Factory
Consult Factory
15.4 oz
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Storage Range
Thermal Shutdown Range
Humidity Max., Non-Condensing
Vibration, 3 Axes, 5 Min Each
MTBF† (Bellcore TR-NWT-000332)
Safety
Safety: Fusing Recommended.
+ See following two pages for Terminal Strip Option Drawing
Weight (Approx.)
SEP 25, 2006 revised to MAR 09, 2007
Page 1 of 3
www.power-one.com
XWS DC-DC Series Data Sheet
100 to 192 Watts
Model Selection
INPUT VOLTAGE
INPUT VOLTAGE
RANGE (VOLTS)
MAXIMUM INPUT
CURRENT (AMPS)*
OUTPUT
VOLTAGE (VOLTS)
RATED OUTPUT
CURRENT (AMPS)
RIPPLE & NOISE
pk-pk (mV)
TYPICAL
EFFICIENCY**
MODEL
(VOLTS)
XWS1205
XWS1212
XWS1215TS
XWS1224
XWS2405
XWS2412
XWS2415
XWS2424
XWS4805TS
XWS4812
XWS4815
XWS4824
XWS6012
XWS6015
12
12
12
12
24
24
24
24
48
48
48
48
40
40
40
10-20
10-20
10-20
10-20
18-36
18-36
18-36
18-36
36-72
36-72
36-72
36-72
20-60
20-60
20-60
13.9
16.9
16.7
15.7
10.9
12.9
12.8
13.6
5.5
6.5
6.5
6.8
12.4
12.2
12.9
5
20
10.4
8.3
5
30
15
12
8
30
15
12
8
15
12
8
50
79%
81%
82%
84%
83%
85%
86%
86%
82%
85%
85%
86%
80%
81%
82%
12
15
24
5
12
15
24
5
12
15
24
12
15
24
120
150
240
50
120
150
240
50
120
150
240
120
150
240
XWS6024
NOTES:
*
Maximum input current at minimum input voltage, maximum rated output power.
** At nominal V , rated output.
in
Model numbers highlighted in yellow or shaded are not recommended for new designs.
Mechanical Drawing
Thermal Impedance
Natural Convection
100 LFM
200 LFM
300 LFM
400 LFM
2.5 °C/W
2.1 °C/W
1.7 °C/W
1.3 °C/W
1.1 °C/W
Note:
Thermal impedance data is dependent on
many environmental factors. The exact
thermal performance should be validated
for specific application.
Pin
Function
1
No Pin
2
3
4
5
6
7
-V
in
-V
+V
in
in
in
+V
Enable
Case
8
9
-V
out
-V
+V
out
10
11
12
13
14
out
out
+V
- Sense
Trim
+ Sense
Tolerances
Inches:
.XX ± 0.040
.XXX ± .010
(Millimeters)
.X ± 1.0
.XX ± 0.25
Pin:
± 0.002
± 0.05
SEP 25, 2006 revised to MAR 09, 2007
Page 2 of 3
www.power-one.com
XWS DC-DC Series Data Sheet
100 to 192 Watts
Terminal Strip Option Drawing
0.52"
(13.2mm)
DIA 0.041" 13PLS.
(1.04mm)
#4-40 THREADED INSERTS 4PLS.
1
2
3
4
5
6
7
8
9
0.375" EA.
(9.53mm)
DIA 0.18"
(4.6mm)
10
11
12
13
14
0.25"
(6.4mm)
3.50"
(88.90mm)
3.000"
(76.20mm)
0.92"
(23.4mm)
4.300"
(109.22mm)
5.50"
(139.7mm)
PIN VIEW
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
TOLERANCES:
.X }.030
.XX }.040
.XXX }.010
FRACTION }.030
Models Available with Terminal Strip
XWS1215TS
XWS2405TS
XWS2412TS
XWS4805TS
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical compo-
nents in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the
respective divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
SEP 25, 2006 revised to MAR 09, 2007
Page 3 of 3
www.power-one.com
相关型号: