MWS020ZGY9 [BEL]
1-OUTPUT 20W DC-DC REG PWR SUPPLY MODULE;型号: | MWS020ZGY9 |
厂家: | BEL FUSE INC. |
描述: | 1-OUTPUT 20W DC-DC REG PWR SUPPLY MODULE 输出元件 |
文件: | 总3页 (文件大小:75K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MWS DC-DC Series Data Sheet
Single-Output, 20 Watts
Features
•
•
•
•
•
•
•
•
20W standard package
100°C case operation
3.3V output available
Integrated heat sink
Enable and trim pins
Wide range input voltage
1500V isolation
Short circuit protection
Description
MWS DC-DC converters provide up to 20 watts of output power in an industry-standard package and footprint. The
MWS is available in either 24V or 48V input versions. With a maximum case temperature of 100°C, the MWS is
well suited for the most demanding telecom, networking, and industrial applications. The MWS features 1500 VDC
isolation, short circuit, and overtemperature protection.
Efficiency vs. Load (24V Input)
Technical Specifications
85
Input
80
Voltage Range
24 VDC Nominal
48 VDC Nominal
Input Undervoltage Lockout
UVLO Hysteresis
Reflected Ripple
Input Reverse Voltage Protection
18 - 36 VDC
33 - 75 VDC
<33V or <18V
1V Nominal
50 mA
Shunt Diode
75
70
65
60
MWS020YGY
EFF. (18v)
EFF. (24v)
EFF. (36v)
Output
Rated
Setpoint Accuracy
1.0%
10
20
30
40
50
60
70
80
90
100
LOAD %
Line regulation V Min. - V Max., I
0.2% V
in
in
out
out
Load Regulation I
Min. - I
Max., V Nom.
0.5% V
out
out
in
out
Minimum Output Current
5 %
Efficiency vs. Load (48V Input)
Dynamic Regulation, Loadstep
25% I
out
Pk Deviation
4% V
out
90
85
80
75
70
65
60
55
50
Settling Time
Voltage Trim Range
Short Circuit / Overcurrent Protection
Current Limit Threshold Range, % of I
500 µs
10%
Shutdown / Hiccup
Rated
110 - 140%
out
MWS020ZGY
EFF. (33v)
EFF. (48v)
EFF. (75v)
General
Turn-On Time, Max.
Remote Shutdown
Switching Frequency
Isolation
175 ms Max.
Positive Logic
450 kHz
10
20
30
40
50
60
70
80
90
100
LOAD %
Input - Output
Temperature Coefficient
Case Temperature
1500 VDC
0.015%/°C
Operating Range
Storage Range
-40 To +100°C
-40 To +105°C
95%
Notes
MTBF predictions may vary slightly from model to model.
†
Humidity Max., Non-Condensing
Vibration, 3 Axes, 5 Min Each
5 g, 10 - 55 Hz
Specifications typically at 25°C, normal line, and full load, unless
otherwise stated.
6
†
MTBF (Bellcore TR-NWT-000332)
Safety
1.9 x 10 hrs
UL, cUL, TUV
1.2 oz
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible
with commercial wave-soldering equipment.
Weight (approx.)
REV. DEC 01, 2003
Page 1 of 3
MWS DC-DC Series Data Sheet
Single-Output, 20 Watts
Model Selection
INPUT VOLTAGE
INPUT VOLTAGE
RANGE (VOLTS)
MAXIMUM INPUT
CURRENT (AMPS)*
OUTPUT
VOLTAGE (VOLTS)
RATED OUTPUT
CURRENT (AMPS)
RIPPLE & NOISE
pk-pk (mV)
TYPICAL
EFFICIENCY**
MODEL
(VOLTS)
MWS020ZGY
MWS020ZHY
MWS020YJY
48
48
24
33 - 75
33 - 75
18 - 36
0.77
0.73
1.34
5
4
75
120
150
81%
85%
85%
12
15
1.66
1.33
NOTES:
*
Maximum input current at minimum input voltage, maximum rated output power.
** At nominal V , rated output.
in
Mechanical Drawing
Pin
Function
Tolerances
Thermal Impedance
Natural Convection
100 LFM
200 LFM
300 LFM
400 LFM
11.5 °C/W
Inches:
.XX 0.020
.XXX 0.010
(Millimeters)
.X 0.5
.XX 0.25
1
2
+ V
in
10.2 °C/W
8.5 °C/W
6.5 °C/W
5.4 °C/W
- V
in
3
4
5
No Pin
Pin:
0.002
Shutdown
No Pin
0.05
Note:
6
+ V
Thermal impedance data is dependent on many
environmental factors. The exact thermal perfor-
mance should be validated for specific application.
out
Case:
+ 0.04, - 0.00
7
8
- V
+ 1.0, - 0.00
out
Trim
(Dimensions as listed unless otherwise
specified.)
REV. DEC 01, 2003
Page 2 of 3
OPTIONS
This page is offered as a reference. Consult factory for actual availability of options. When ordering
equipment options, use the following suffix information. Select preferred option(s) and add the suffix to the
model number. Ordering option examples are located below the options table.
OPTION
Negative Logic
SUFFIX
APPLICABLE SERIES
REMARKS
N
HAS, HBD, HBS, HES, HLS, HLD, LES,
QBS, QES, QLS, TES, TQD
TTL "Low" Turns Module ON
TTL "High" Turns Module OFF
Lucent-Compatible Trim
T
HAS, HBD, HBS, HES, HLS, QBS, QES,
QLS
Trim
1
2
3
IAS, LES
Enable
IAD, IAS, LES, SMS
IAS, LES
Trim and Enable
Pin Length and Heatsink Options
0.110" (2.8mm) Pin Length
Standard Pin Length is 0.180" (4.6mm)
8
9
All Leaded Models
All Leaded Models
0.150" (3.8mm) Pin Length
0.24" (6.1mm) Horizontal Heatsink
1H
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
0.24" (6.1mm) Vertical Heatsink
0.45" (11.4mm) Horizontal Heatsink
0.45" (11.4mm) Vertical Heatsink
0.95" (24.1mm) Horizontal Heatsink
0.95" (24.1mm) Vertical Heatsink
1V
2H
2V
3H
3V
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
Example Options:
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of
Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
REV. DEC 01, 2003
Page 3 of 3
相关型号:
©2020 ICPDF网 联系我们和版权申明