LS4001-7EPD8B2 [BEL]
AC-DC Power Factor Correction Module, 1 Output, 100W, Hybrid, METAL, CASE S02, MODULE;型号: | LS4001-7EPD8B2 |
厂家: | BEL FUSE INC. |
描述: | AC-DC Power Factor Correction Module, 1 Output, 100W, Hybrid, METAL, CASE S02, MODULE 电源电路 |
文件: | 总27页 (文件大小:598K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Cassette Style
100 Watt AC-DC Converters
S Series PFC
100 Watt AC-DC Converters with PFC
S Series
Input voltage range from 85...264 V AC
1 or 2 isolated outputs up to 48 V DC
4 kV AC I/O electric strength test voltage
• Universal input voltage range
• Power factor >0.95, harmonics <IEC/EN 61000-3-2
• Input over- and undervoltage lock-out
• Efficient input filter and built-in surge and transient
suppression circuitry
• Fully isolated outputs
• Outputs overload, open- and short-circuit proof
• No derating over entire operating temperature range
Safety according to IEC/EN 60950
LGA
111
4.4"
3 U
60
168
2.4"
6.6"
12 TE
Summary
The S 4000/S 5000 series of AC-DC converters represents
a flexible range of power supplies for use in advanced elec-
tronic systems. Features include full power factor correc-
tion, high efficiency, high reliability, low output voltage noise
and excellent dynamic response to load/line changes.
agencies LGA (Germany) and UL (USA). The UL Mark for
Canada has been officially recognized by regulatory au-
thorities in provinces across Canada.
The converter inputs are protected against surges and tran-
sients occurring at the source lines. An input over- and
undervoltage lock-out circuitry disables the outputs if the
input voltage is outside the specified range. Inrush current
limitation is included preventing circuit breakers and fuses
from being damaged at switch-on.
The case design allows operation at nominal load up to
71°C in a free air ambient temperature. If forced cooling is
provided, the ambient temperature may exceed 71°C but
the case temperature must remain below 95°C under all
conditions.
A temperature sensor generates an inhibit signal which
disables the outputs if the case temperature TC exceeds
the limit. The outputs are automatically re-enabled when
the temperature drops below the limit.
All outputs are overload, open- and short-circuit proof and
are protected against overvoltages by means of a built-in
suppressor diode. The outputs can be inhibited by a logic
signal applied to the connector pin 18 (i). If the inhibit func-
tion is not used pin 18 must be connected to pin 14 to en-
able the outputs.
Various options are available to adapt the converters to in-
dividual applications.
The modules may either be plugged into 19" rack systems
according to DIN 41494, or be chassis mounted.
LED indicators display the status of the converter and allow
visual monitoring of the system at any time.
Full input to output, input to case, output to case and output
to output isolation is provided. The modules are designed
and built according to the international safety standards
IEC/EN 60950 and have been approved by the safety
Important:
These products are intended to replace the LS 1000 and
LS 2000 in order to comply with IEC/EN 61000-3-2.
Table of Contents
Page
Page
Summary .......................................................................... 1
Type Survey and Key Data .............................................. 2
Type Key .......................................................................... 2
Functional Description...................................................... 3
Electrical Input Data ......................................................... 4
Electrical Output Data ...................................................... 6
Auxiliary Functions ......................................................... 11
Electromagnetic Compatibility (EMC) ............................ 15
Immunity to Environmental Conditions........................... 17
Mechanical Data ............................................................ 18
Safety and Installation Instructions ................................ 19
Description of Options.................................................... 22
Accessories.................................................................... 27
Edition 01/01.2001
1/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
Type Survey and Key Data
Non standard input/output configuration or special custom adaptions are available on request. See also: Commercial Infor-
mation: Inquiry Form for Customized Power Supply.
Table 1: Type survey LS
Output 1
Output 2
Input Voltage Range
Ui min...Ui max
Efficiency 1
hmin
Options
Uo nom
Io nom
[A] 2
Uo nom
Io nom
[A] 2
[V DC]
[V DC]
85...255 V AC 6
[%]
5.1
16.0
8.0
6.5
LS 4001-7R
LS 4301-7R
LS 4501-7R
LS 4601-7R
77
81
83
83
-9
E
D
V 5
P
T
B1
B2
12.0
15.0
24.0
4.2
24.0 3
30.0 3
48.0 3
4.0
3.2
2.0
LS 5320-7R
LS 5540-7R
LS 5660-7R
81
81
81
12.0
15.0
24.0
4.0
3.2
2.0
12.0 4
15.0 4
24.0 4
4.0
3.2
2.0
LS 5320-7R
LS 5540-7R
LS 5660-7R
81
81
81
1 Efficiency at Ui nom and Io nom
.
3 Series connection of output 1 and 2, see: R-Function for differ-
ent output configurations.
2 If the output voltages are increased above Uo nom via R-input
control, option P setting, remote sensing or option T, the output
currents must be reduced accordingly so that Po nom is not ex-
ceeded.
4 Second output semi-regulated.
5 Option V for LS 4000 types with 5 V outputs.
6 For DC-input please ask your local Power-One partner.
Type Key
Type Key
L S 5 5 40 -7 E R P D V T B1
Input voltage range Ui: 85...255 V AC .............................. L
Series ...............................................................................S
Number of outputs (4 for single, 5 for double outputs) 4...5
Single output units:
Nominal voltage output 1 (main output), Uo1 nom
5.1 V .................................................... 0, 1, 2
12 V ............................................................. 3
15 V ......................................................... 4, 5
24 V ............................................................. 6
other voltages .......................................... 7, 8
Other specifications for single output modules ....... 01...99
Symmetrical double output units:
Nominal voltage output 1/output 2, Uo1/2 nom
12 V/12 V 1 (24 V series conn.).................. 20
15 V/15 V 1 (30 V series conn.).................. 40
24 V/24 V 1 (48 V series conn.).................. 60
other symmetrical voltages ................. 70...99
Operational ambient temperature range TA:
–25...71°C .................................................. -7
–40...71°C .................................................. -9
customer specific .................................. -0...-6
Auxiliary functions and options:
Inrush current limitation ...............................E
Output voltage control input ........................ R 2
Potentiometer (output voltage adjustment)..P 2
Save data signal (D0...DD, to be specified) D 3
ACFAIL signal (V2, V3)................................V 3, 4
Current sharing ............................................ T
Cooling plate standard case ......................B1
Cooling plate for longe case 220 mm ........ B2
1 External wiring of main and second output depending upon the desired output configuration (see: R-Function for different output con-
figurations).
2 Feature R excludes option P and vice versa.
3 Option D excludes option V and vice versa.
4 Option V available for LS 4000 types with 5V output.
Edition 01/01.2001
2/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
Functional Description
The input voltage is fed via an input fuse, an input filter, a
rectifier and an inrush current limiter to a single transistor
boost converter. This converter provides a sinusoidal input
current (IEC/EN 61000-3-2, class D equipment) and sour-
ces a capacitor with a voltage of 360-370 V DC. This ca-
pacitor sources a single transistor forward converter.
filter. The control logic senses the main output voltage Uo1
and generates, with respect to the maximum admissible
output currents, the control signal for the primary switching
transistor.
The second output of double output units is controlled by
the main output, but has independent current limiting. If the
main output is driven into current limitation, the second out-
put voltage will fall as well and vice versa.
Each output is powered by a separate secondary winding
of the main transformer. The resultant voltages are rectified
and their ripples smoothed by a power choke and an output
P
03001
16
18
20
22
12
4
R
i
D/V
T
S+
Y
26
28
N
1
3
Y
Y
Vo+
Ci
+
6
4
8
Vo–
10
2
30
32
P~
14 S–
Y
24
–
+
Fig. 1
Block diagram of single output converters LS 4000
P
03002
16
R
26
28
18 i
Y
N~
D
20
22
T
1
3
Y
Y
Ci
+
12
Vo1+
4
14
4
6
Vo1–
Y
2
Vo2+
30
32
P~
8
10
Vo2–
Y
Y
24
–
+
Fig. 2
Block diagram of symmetrical double output converters LS 5000
1 Transient suppressor (VDR)
2 Inrush current limiter (NTC or Opt. E), -9 versions exclude the NTC
3 Input fuse
4 Hold-up capacitor
Edition 01/01.2001
3/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
Electrical Input Data
General Conditions
– TA = 25°C, unless TC is specified.
– Pin 18 connected to pin 14, Uo adjusted to Uo nom (option P); R input not connected.
– Sense line pins S+ and S– connected to Vo+ and Vo– respectively.
Table 2: Input data
Input
LS
Characteristics
Conditions
min
85
typ
max
255
Unit
Ui
Operating Input voltage Io = 0...Io nom
TC min...TC max
V AC 3,4
Ui nom Nominal Input voltage
230
0.55
9.0
1
Ii
Input current
Ui nom, Io nom
Arms
W
Pi0
Pi inh
Ri
No-load input power
Idle input power
Input resistance
Ui min…Ui max
unit inhibited
TC = 25°C
10
5
3.5
480
mΩ
µF
RNTC NTC resistance 2
Ci Input capacitance
3200 4000
80
100
B
120
Ui RFI Conducted input RFI
Radiated input RFI
EN 55022
Ui nom, Io nom
B
Ui abs Input voltage limits
without damage
–400
–400
400
400
V DC
Vp
1 With double output modules, both outputs loaded with Io nom
.
2 Valid for -7 versions with NTC, (-9 versions exclude the NTC). Initial switch-on cycle. Subsequent switch-on/off cycles increase the in-
rush current peak value.
3 AC frequency range 47...63 Hz.
4 For DC-input please ask your local Power-One partner.
Input Fuse
Reverse Polarity Protection
A fuse mounted inside the converter protects the module
against severe defects. (If operated from a DC-source this
fuse may not fully protect the module when the input volt-
age exceeds 200 V DC! In applications where the convert-
ers operate at source voltages above 200 V DC an external
fuseora circuit breaker at system level should be installed!)
Should the input voltage to the unit be supplied from a DC
source the built-in bridge rectifier provides reverse polarity
protection. (For DC-input operation, please consult your lo-
cal Power-One partner.)
Inrush Current Limitation
The modules of the versions -7, incorporate an NTC resis-
tor in the input circuitry which – at initial turn on – reduces
the peak inrush current value by a factor of 5...10 to protect
connectors and switching devices from damage. Subse-
quent switch-on cycles within short periods will cause an
increase of the peak inrush current value due to the warm-
ing-up of the NTC resistor. See also: E option.
Table 3: Fuse Specification
Module
Fuse type
Fuse rating
LS 1
slow-blow
SP T
4 A, 250 V
1 Fuse size 5 × 20 mm
Input Under-/Overvoltage Lock-out
If the input voltage remains below approx. 65 V AC or ex-
ceeds approx. 280 V AC an internally generated inhibit sig-
nal disables the output(s). When checking this function the
absolute maximum input voltage rating Ui abs should be
considered! Between Ui min and the undervoltage lock-out
level the output voltage may be below the value defined in
table: Output data (see: Technical Information: Measuring
and Testing).
Inrush Current Peak Value
The inrush current peak value (initial switch-on cycle) can
be determined by following calculation:
Ui rms • √2
Iinr p = ––––––––––––––––
(Rs ext + Ri + RNTC
)
04001
Rs ext Iinr p
Ri
RNTC
Input Transient Protection
A VDR together with the input fuse and a symmetrical input
filter form an effective protection against high input tran-
sient voltages.
Ci
Ui rms
Fig. 3
Equivalent circuit diagram for input impedance.
Edition 01/01.2001
4/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
Input Inrush Current Characteristic
Static Input current Characteristic
li [Arms
]
Iinr [A]
04005
04006
3
2.5
2
130
100
1.5
1
Ui = 255 Vrms
Ui = 115 Vrms
Ui [V AC]
300
0.5
50
100
150
200
250
Fig. 6
50
1
Input current versus input voltage at Io nom
Power Factor, Harmonics
Power factor correction is achieved by controlling the input
current waveform synchronously with the input voltage
waveform. The power factor control is active under all oper-
ating conditions.
0
1
2
3 t [ms]
Fig. 4
Power Factor
Theoretical input inrush current versus time at Ui 255 Vrms
and 115 Vrms, Rext = 0.
04004
1
0.95
Harmonic Currents
0.9
The harmonic distortion is well below the limits specified in
IEC/EN 61000-3-2, class D.
Ui = 230 V AC
0.85
Ui = 85 V AC
I [mA/W]
3.5
0.8
0.75
0.7
04042
i
3.0
Limit class D according
to IEC/EN 61000-3-2
0.2
0.4
0.6
0.8
1
Io/Io nom
0
2.5
Fig. 7
2.0
1.5
1.0
0.5
Power factor versus output current at Ui 230 V AC and
85 V AC.
Harm.
0
3
5
7
9
11
13 15
17 19
Fig. 5
Harmonic currents at the input, IEC/EN 61000-3-2,
class D. Ui = Ui nom, Io = Io nom
.
Edition 01/01.2001
5/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
Electrical Output Data
General Conditions
– TA = 25°C, unless TC is specified.
– Pin 18 (i) connected to pin 14 (S–/Vo1–), Uo adjusted to Uo nom (option P), R input not connected.
– Sense line pins 12 (S+) and 14 (S–) connected to pins 4 (Vo1+) and 8 (Vo1–) respectively.
Table 4a: Output data single output modules
Output
LS 4001
5.1 V
LS 4301
12.0 V
LS 4501
15.0 V
LS 4601
24.0 V
Characteristics
Conditions
min typ max min typ max min typ max min typ max Unit
Uo
Output voltage
Ui nom, Io nom
5.07
5.13 11.93
12.07 14.91
15.09 23.86
24.14
V
Uop
Overvoltage protection
(supressor diode)
7.6
21
26.5
6.5
43.5
4.2
Io nom Output current 1
Ui min...Ui max
TC min...TC max
16.0
8.0
A
IoL
uo
Output current limit 2
Ui min...Ui max
16.2
8.2
6.7
4.4
5
Output Low frequency Ui nom, Io nom
2
2
5
2
5
2
5
mVpp
voltage
noise
IEC/EN 61204
BW = 20 MHz
Switching freq.
Total
15
50
40
40
40
DUo U Static line regulation
Ui min...Ui nom
Ui nom...Ui max
Io nom
,
,
±5
±12
±15
±24 mV
DUo I Static load regulation
Ui nom, Io =
(0.1...1) Io nom
20
24
30
48
3
uo d
Dynamic Voltage
Ui nom, Io =
±170
±150
±150
±100
load
deviation
I
o nom ↔ 1/
2
Io nom
regulat.
IEC/EN 61204
3
t d
Recovery time
0.3
0.4
0.4
0.3
1.5
ms
aUo
Temperature coefficient Ui min...Ui max
of output voltage 4
0...Io nom
–0.5
-1.5
-1.5
mV/K
1 If the output voltages are increased above Uo nom through R-input control, option P setting, remote sensing or option T, the output cur-
rents should be reduced accordingly so that Po nom is not exceeded.
2 See: Output Voltage Regulation of Single or Double Output Modules with Outputs 1 and 2 Connected in Series.
3 See: Typical dynamic load regulation of Uo1 and Uo2.
4 Negative temperature coefficient (0...–3 mV/cell and K) available on request.
5 Measured according to IEC/EN 61204 sub clause 3.10 with a probe acc. to annex A of the same standards. (See:Technical Informa-
tion: Measuring and Testing)
Edition 01/01.2001
6/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
Table 4b: Output data double output modules
Output
LS 5320
24 V (2 × 12 V)
LS 5540
30 V (2 × 15 V)
LS 5660
48 V (2 × 24 V)
(Outputs connected in Series)
Characteristics
Conditions
min
typ
24.0
38
max
min
typ
30.0
48
max
min
typ
48.0
74
max
Unit
V
Uo
Output voltage 2
Ui nom, Io nom
Uop
Overvoltage protection
(supressor diode)
Io nom Output current 1
Ui min...Ui max
TC min...TC max
4.0
3.2
2.0
A
IoL
uo
Output current limit 4
Ui min...Ui max
4.2
3.4
2.1
7
Output Low frequency Ui nom, Io nom
3
3
5
mVpp
voltage
noise 3
IEC/EN 61204
BW = 20 MHz
Switching freq.
Total
15
15
20
100
100
150
DUo U Static line regulation
Ui min...Ui max
Io nom
±12
±15
±24
mV
DUo I Static load regulation
Ui nom, Io =
(0.1...1) Io nom
40
60
96
5
uo d
Dynamic Voltage
Ui nom, Io =
±250
±200
±150
load
deviation
I
o nom ↔ 1/
2
Io nom
regulat.
IEC/EN 61204
5
t d
Recovery time
0.3
0.3
0.3
ms
aUo
Temperature coefficient Ui min...Ui max
of output voltage 6
0...Io nom
–2.2
–2.2
–2.6
mV/K
1 If the output voltages are increased above Uo nom through R-input control, option P setting, remote sensing or option T, the output cur-
rents should be reduced accordingly so that Po nom is not exceeded.
2 Series connection for Uo nom = 24 V, 30 V or 48 V, see: R-Function for different output configurations.
3 Shortest possible wiring for series connection at the connector.
4 See: Output Voltage Regulation of Single or Double Output Modules with Outputs 1 and 2 Connected in Series.
5 See: Typical dynamic load regulation of Uo1 and Uo2.
6 Negative temperature coefficient (0...-3 mV/cell and K) available on request.
7 Measured according to IEC/EN 61204 sub clause 3.10 with a probe acc. to annex A of the same standards. (See:Technical Informa-
tion: Measuring and Testing)
Edition 01/01.2001
7/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
Table 4c: Output data double output modules
Output
LS 5320
12 V/12 V
LS 5540
15 V/15 V
(Outputs independently loaded) 1
Characteristics
Conditions
Output 1
Output 2
Output 1
Output 2
min typ max min typ max min typ max min typ max Unit
2
Uo
Output voltage
Ui nom, Io nom
11.93
12.07 11.82
12.18 14.91
15.09 14.78
15.23
V
A
Uop
Overvoltage protection
(supressor diode)
19
19
24
24
Io nom Output current 3
Ui min...Ui max
TC min...TC max
4.0
4.0
3.2
3.2
IoL
uo
Output current limit 4
Ui min...Ui max
4.2
4.2
3.4
3.4
8
Output Low frequency Ui nom, Io nom
3
3
3
3
mV
pp
voltage
noise
IEC/EN 61204
BW = 20 MHz
Switching freq.
Total
12
80
12
40
10
10
40
100
DUo U Static line regulation
Ui min...Ui nom
Ui nom...Ui max
Io nom
±12
±12
±15
±15 mV
5
5
DUo I Static load regulation
Ui nom, Io =
(0.1...1) Io nom
48
60
5
6
uo d
Dynamic Voltage
Ui nom, Io =
±100
±100
load
deviation
I
o nom ↔ 1/
2
Io nom
regulat.
IEC/EN 61204
6
t d
Recovery time
0.3
0.3
ms
aUo
Temperature coefficient Ui min...Ui max
of output voltage 7
0...Io nom
–1.5
–1.5
mV/K
Table 4d: Output data double output modules
Output
LS 5660
24 V/24 V
1 Depending upon the desired out-
put configuration the wiring should
be made as shown in: R-Function
for different output configurations.
2 Same conditions for both outputs.
3 If the control voltages are in-
creased above Uo nom via R-input
control, option Psetting, remote
sensing or option T, the output
currentsshould be reduced ac-
cordingly so that Po nom is not ex-
ceeded.
(Outputs independently loaded) 1
Characteristics
Conditions
Output 1
Output 2
min typ max min typ max Unit
2
Uo
Output voltage
Ui nom, Io nom
23.86
24.14 23.64
24.36
V
A
Uop
Overvoltage protection
(supressor diode)
37
37
Io nom Output current 3
Ui min...Ui max
TC min...TC max
2.0
2.0
IoL
uo
Output current limit 4
Ui min...Ui max
2.1
2.1
4 See: Output Voltage Regulation of
Single or Double Output Modules
with Outputs 1 and 2 Connected
in Series.
8
Output Low frequency Ui nom, Io nom
3
3
mVpp
voltage
noise
IEC/EN 61204
BW = 20 MHz
Switching freq.
Total
10
10
40
5 Condition for specified output.
Other output loaded with constant
current Io = Io nom. See: Output
voltage regulation of double out-
put units.
100
DUo U Static line regulation
Ui min...Ui nom
Ui nom...Ui max
Io nom
,
,
±24
±24 mV
6 See: Typical dynamic load regula-
5
DUo I Static load regulation
Ui nom, Io =
(0.1...1) Io nom
96
5
tion of Uo1 and Uo2
.
7 Negative temperature coefficient
(0....–3 mV/cell and K) available
on request.
6
uo d
Dynamic Voltage
Ui nom, Io =
±80
load
deviation
I
o nom ↔ 1/
2
Io nom
regulat.
IEC/EN 61204
8 Measured according to IEC/EN
61204 sub clause 3.10 with a
probe acc. to annex A of the same
standards.
6
t d
Recovery time
0.3
ms
aUo
Temperature coefficient Ui min...Ui max
of output voltage 7
0...Io nom
–0.5
mV/K
Edition 01/01.2001
8/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
Thermal Considerations
Parallel or Series Connection of Units
If a converter is located in free, quasi-stationary air (con-
vection cooling) at the indicated maximum ambient tem-
perature TA max (see table: Temperature specifications) and
is operated at its nominal input voltage and output power,
the temperature measured at the Measuring point of case
temperature TC (see: Mechanical Data) will approach the
indicated value TC max after the warm-up phase. However,
the relationship between TA and TC depends heavily on the
conditions of operation and integration into a system. The
thermal conditions are influenced by input voltage, output
current, airflow and temperature of surrounding compo-
Single or double output units with equal nominal output volt-
age can be connected in parallel without any precautions
using option T.
With option T (current sharing), all units share the current
approximately equally.
Single output units and/or main and second outputs of dou-
ble output units can be connected in series with any other
(similar) output.
Note:
– Parallel connection of double output units should always
include both, main and second output to maintain good
regulation of both outputs.
nents and surfaces. TA max is therefore, contrary to TC max
,
an indicative value only.
– Not more than 5 units should be connected in parallel.
– Series connection of second outputs without involving
their main outputs should be avoided as regulation may
be poor.
Caution: The installer must ensure that under all operat-
ing conditions TC remains within the limits stated in the
table: Temperature specifications.
– The maximum output current is limited by the output with
the lowest current limitation if several outputs are con-
nected in series.
Notes: Sufficient forced cooling or an additional heat sink
allows TA to be higher than 71°C (e.g. 85°C) if TC max is not
exceeded.
For -7 or -9 units at an ambient temperature TA of 85°C with
only convection cooling, the maximum permissible current
for each output is approx. 40% of its nominal value as per
figure.
Output Voltage Regulation of Single or Double Output
Modules with Outputs 1 and 2 Connected in Series
Uo
Uo nom
05001
Io/Io nom
0.98
Forced cooling
1.0
0.9
0.8
0.7
Convection cooling
0.5
0.6
Io1
TC max
0.5
IoL
0.4
0.3
0.2
0.1
Io
Io nom
0
0.5
1.0
0
Fig. 9
o1 vs. Io1 (typ.) of single output units
T [°C]
A
T
50
60
70
80
90
100
A min
U
Fig. 8
Output current derating versus temperature for -7 and -9
units.
Output Voltage Regulation of Double Output Modules
Output 1 is under normal conditions regulated to Uo1 nom
,
Thermal Protection
independent of the output currents.
A temperature sensor generates an internal inhibit signal
which disables the outputs if the case temperature exceeds
TC max. The outputs are automatically re-enabled if the tem-
perature drops below this limit.
Uo2 is dependent upon the load distribution. If both outputs
are loaded with more than 10% of Io nom, the deviation of
Uo2 remains within ±5% of the value of Uo1. The following 3
figures show the regulation with varying load distribution. If
Io1 = Io2 or the two outputs are connected in series, the de-
viation of Uo2 remains within ±1% of the value of Uo1 pro-
vided that a total load of more than 10% of Io nom is applied.
It is recommended that continuous operation under simul-
taneous extreme worst case conditions of the following
three parameters be avoided: Minimum input voltage,
maximum output power and maximum temperature.
Two outputs of a single S 5000 module connected in paral-
lel will behave like the output of a S 4000 module; the paral-
leled output is fully regulated. No precautions are neces-
sary in using the R-input and the test sockets.
Output Protection
Each output is protected against overvoltage which could
occur due to a failure of the control circuit by means of a
voltage suppressor diode which, under worst case condi-
tions, may become a short circuit. The suppressor diodes
are not designed to withstand externally applied over-
voltages. Overload at any of the two outputs will cause a
shut-down of both outputs. A red LED indicates the over-
load condition.
Edition 01/01.2001
9/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
[V] Uo2
Dynamic Load Regulation
Uo1
05083
05005
13
Io1 =100%
Io1 = 50%
Io1 = 10%
Uo1d
Ur
Ur
12.5
12.0
11.5
11
Uo1d
td
td
t
Uo2
Uo2d
10.5
0.4
0.6
0.8
0
0.2
1
Io2/Io2 nom
t
t
Io1/Io1 nom
Io2/Io2 nom
Fig. 10
1
LS 5320: DUo2 (typ.) vs. Io2 with different Io1.
0.5
<10 µs
<10 µs
[V] Uo2
05084
0
16.5
Io1 = 100%
Io1
Io1
Fig. 14
=
=
50%
10%
16
15.5
15
Typical dynamic load regulation of Uo1 and Uo2.
Hold-up Time versus Output Power
time [ms]
180
05013
14.5
14
160
140
120
100
80
13.5
0
0.2
0.4
0.6
0.8
1
Io2/Io2 nom
Fig. 11
LS 5540: DUo2 (typ.) vs. Io2 with different Io1.
60
[V] Uo2
05085
40
27
Io1 = 100%
20
Io1
Io1
=
=
50%
10%
26
25
24
23
22
21
0
0
0.2
0.4
0.6
0.8
1
Io /Io nom
Fig. 15
Hold-up time th versus output power.
Efficiency versus Load
Efficiency
0.90
05014
0.4
0
0.2
0.6
0.8
1
Io2/Io2 nom
0.80
Fig. 12
Ui = 230 V AC
Ui 85 V AC
0.70
0.60
0.50
0.40
0.30
LS 5660: DUo2 (typ.) vs. Io2 with different Io1.
=
Switching Frequency versus Load
Frequency [kHz]
05008
80
70
60
0
0.2
0.4
0.6
0.8
1
Io/Io nom
Fig. 16
Efficiency versus load at Ui; 230 V AC and 85 V AC
50
40
30
20
10
0
0.2
0.4
0.6
0.8
1
1.2
load [Io/Io nom
0
]
Fig. 13
Switching frequency versus load. (The boost converter at
the input stage has a fixed frequency of 100 kHz)
Edition 01/01.2001
10/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
Auxiliary Functions
Sense Lines
i Inhibit for Remote On and Off
(Only for single output units 5.1 V, 12 V, 15 V, 24 V)
Note: With open i input: Output is disabled (Uo = off).
The outputs of the module may be enabled or disabled by
means of a logic signal (TTL, CMOS, etc.) applied between
the inhibit input i and the negative pin of output 1 (Vo1–). In
systems with several units, this feature can be used, for ex-
ample, to control the activation sequence of the converters.
If the inhibit function is not required, connect the inhibit pin
18 to pin 14 to enable the outputs (active low logic, fail
safe). For output response refer to: Hold-up Time and Out-
put Response.
This feature enables for compensation of voltage drops
across the connector contacts and if necessary, across the
load lines. If the sense lines are connected at the load
rather than directly at the connector, the user should ensure
that Uo max (between Vo1+ and Vo1–) is not exceeded. We
recommend connecting the sense lines directly at the fe-
male connector.
For further information, please refer to: Application Notes .
To ensure correct operation, both sense lines (S+ and S–)
should be connected to their respective power outputs
(Vo1+ and Vo1–) and the voltage difference between any
sense line and its respective power output pin (as meas-
ured on the connector) should not exceed the following val-
ues:
06031
Vo+
i
Vi+
Iinh
Uinh
Table 6: Maximum Voltage compensation allowed using
sense lines
Vo–
Vi–
Output
voltage
Total voltage difference Voltage difference
Fig. 17
Definition of Uinh and Iinh
between sense lines and
their respective outputs
between
Vo– and S–
.
5.1 V
<0.5 V
<1.0 V
<0.25 V
<0.25 V
Iinh [mA]
Uinh = 2.4 V
U
inh = 0.8 V
12 V, 15 V
2.0
1.6
1.2
If the output voltages are increased above Uo nom via R-in-
put control, option P setting, remote sensing or option T, the
output currents must be reduced accordingly so that
Po nom is not exceeded.
0.8
0.4
Important: The output terminals Vo1+ and Vo1– must
always be connected to the load before connecting the
sense lines S+ and S–, otherwise the unit will be dam-
aged.
Uo = on
Uo = off
0
–0.4
–0.8
Uinh [V]
–50
–30
–10
0
10
30
50
Fig. 18
Typical inhibit current Iinh versus inhibit voltage Uinh
Table 5: Inhibit characteristics
Characteristic
Conditions
min typ max Unit
Uinh Inhibit Uo = on Ui min…Ui max –50
0.8
50
V
voltage
Uo = off
2.4
Iinh Inhibit current
Uinh = 0
–400 µA
tr
tf
Rise time
30
depending on Io
ms
Fall time
06001
Uo/Uo nom
1
0.1
0
t
tf
tr
Inhibit
1
t
0
Fig. 19
Output response as a function of inhibit control
Edition 01/01.2001
11/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
Programmable Output Voltage (R-Function)
As a standard feature, the modules offer an adjustable out-
put voltage, identified by letter R in the type designation.
The control input R (pin 16) accepts either a control voltage
Uext or a resistor Rext to adjust the desired output voltage.
When not connected, the control input automatically sets
– If the output voltages are increased above Uo nom via R-
input control, option P setting, remote sensing or option
T, the output current(s) should be reduced accordingly so
that Po nom is not exceeded.
– The R-input (as well as option P) is related to the main
output.
the output voltage to Uo nom
.
a) Adjustment by means of an external control voltage Uext
between pin 16 (R) and pin 14:
– With double output units the second output follows the
value of the controlled main output. Resistor values as
indicated for the single output units should be used.
The control voltage range is 0...2.75 V DC and allows an
output voltage adjustment in the range of approximately
– For correct output voltage adjustment of double output
units the external wiring of the outputs should be accord-
ing to fig.: R-Function for different output configuration
depending upon the desired output configuration.
0...110% Uo nom
U
.
Uext = –––o––– • 2.5 V (approximate formula)
Uo nom
b) Adjustment by means of an external resistor:
– In case of parallel connection the output voltages should
Depending upon the value of the required output voltage
the resistor shall be connected
be individually set within a tolerance of 1...2%.
06003
Vo1+
R
N
either: Between pin 16 and pin 14 (Uo < Uo nom) to
achieve an output voltage adjustment range of approxi-
mately 0...100% Uo nom
+
16
14
Module
Module
Uext
S–
or: Between pin 16 and pin 12 (Uo > Uo nom) to achieve
an output voltage adjustment range of approximately
Vo1–
P
N
100...110% Uo nom
.
Vo1+
Warning:
S+
R
12
– Uext shall never exceed 2.75 V DC.
R'ext
Rext
16
14
– The value of R'ext shall never be less than the lowest
value as indicated in table R'ext (for U0 >U0 nom) to avoid
damage to the unit!
S–
Vo1–
P
Remarks:
Fig. 20
Output voltage control for single output units LS 4000 by
means of the R input
– The R-Function excludes option P (output voltage ad-
justment by potentiometer).
Table 7a: Rext for Uo < Uo nom; approximative values (Ui nom, Io nom, series E 96 resistors); R'ext = ∞
Uo nom = 5.1 V
Uo (V) Rext [kΩ]
Uo nom = 12 V
Uo [V] 1
Uo nom = 15 V
Uo [V] 1
Uo nom = 24 V
Uo [V] 1
Rext [kΩ]
Rext [kΩ]
Rext [kΩ]
0.806
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
0.432
0.976
1.65
2.61
3.83
5.76
8.66
14.7
30.1
200
2
3
4
5
6
7
8
9
10
11
4
6
8
10
12
14
16
18
20
22
0.806
1.33
2
2.87
4.02
5.62
8.06
12.1
20
2
4
6
8
9
10
11
12
13
14
4
8
0.619
1.47
2.67
4.53
6.04
8.06
11
16.2
26.1
56.2
4
6
8
10
12
14
16
18
20
22
8
12
16
20
24
28
32
36
40
44
1.33
2
2.87
4.02
5.62
8.06
12.1
20
44.2
12
16
18
20
22
24
26
28
42.2
Table 7b: R’ext for Uo > Uo nom; approximative values (Ui nom, Io nom, series E 96 resistors); Rext = ∞
Uo nom = 5.1 V
Uo [V] R'ext [kΩ]
5.15 432
Uo nom = 12 V
Uo [V] 1
Uo nom = 15 V
Uo [V] 1
Uo nom = 24 V
R'ext [kΩ]
R'ext [kΩ]
Uo [V] 1
R'ext [kΩ]
12.1
12.2
12.3
12.4
12.5
12.6
12.7
12.8
13.0
13.2
24.2
24.4
24.6
24.8
25.0
25.2
25.4
25.6
26.0
26.4
1820
931
619
475
383
316
274
243
196
169
15.2
15.4
15.6
15.8
16.0
16.2
16.4
16.5
30.4
30.8
31.2
31.6
32.0
32.4
32.8
33.0
1500
768
523
392
316
267
232
221
24.25
24.5
24.75
25.0
25.25
25.5
25.75
26.0
48.5
49.0
49.5
50.0
50.5
51.0
51.5
52.0
52.5
52.8
3320
1690
1130
845
698
590
511
442
402
383
5.2
5.25
5.3
215
147
110
5.35
5.4
88.7
75
5.45
5.5
64.9
57.6
26.25
26.4
1 First column: single output units or double output units with separated outputs, second column: outputs in series connection
Edition 01/01.2001
12/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
R-Function for different output configurations
06004
06005
+
Vo2+
+
4
Vo2+
Vo2+
Vo2–
Vo2–
Vo1+
Vo1–
4
6
Vo2+
Vo2–
Vo2–
Vo1+
Vo1–
6
8
12 V
15 V
24 V
1
Uo1
24 V
30 V
48 V
8
1
Uo1
10
12
14
–
10
12
2
–
14
16
Rext R'ext
Rext R'ext
16
R
R
Fig. 21a
Fig. 21b
LS 5000 with H15 connector. R-input for output voltage
control. Wiring for output voltage 24 V or 30 V or 48 V with
main and second output connected in series.
LS 5000 with H15 connector. R-input for output voltage
control. Wiring for output voltage 12 V or 15 V or 24 V
with main and second output connected in parallel.
06006
06007
+24/+30/+48 V
0 V
Vo2+
Vo2+
Vo2–
Vo2–
Vo1+
Vo1–
4
6
Vo2+
Vo2+
Vo2–
Vo2–
Vo1+
Vo1–
+
4
6
1
1
Uo2
–12/–15/–24 V
8
–
8
Uo2
+12/+15/+24 V
0 V
Uo1
10
12
+
10
12
2
1
1
Uo1
+12/+15/+24 V
+
14
16
14
16
Rext R'ext
Rext R'ext
R
R
Fig. 21c
Fig. 21d
LS 5000 with H15 connector. R-input for output voltage
control. Wiring of main and second output for two output
voltages Uo1 and Uo2: +12 V and +24 V or +15 V and
+30 V or +24 V and +48 V.
LS 5000 with H15 connector. R-input for output voltage
control. Wiring of main and second output for two sym-
metrical output voltages Uo1 and Uo2: ±12 V or ±15 V or
±24 V.
1 A ceramic multilayer capacitor connected across the load re-
duces ripple and spikes.
06008
+
Vo2+
Vo2+
Vo2–
Vo2–
Vo1+
Vo1–
4
6
2 Shortest possible wiring for series connection at the female con-
nector
12 V
15 V
24 V
1
1
Uo2
–
8
+
10
12
12 V
15 V
24 V
Uo1
–
Remarks:
14
16
Rext R'ext
Double output units fitted with H15 connectors have the
output pins of the second output, pins 4/6 and 8/10, inter-
nally paralleled.
R
It is recommended that pins 4/6 and 8/10 be directly paral-
leled at the female connector as well to reduce the voltage
drop across the connector.
Fig. 21e
LS 5000 with H15 connector. R-input for output voltage
control. Wiring of main and second output for two output
voltages Uo1 and Uo2: 12 V/12 V or 15 V/15 V or
24 V/24 V, the outputs are galvanically isolated.
Please note: Uo2 varies depending upon its own load and
the load on output 1.
Edition 01/01.2001
13/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
Display Status of LEDs
06002
Uo1 > 0.95...0.98Uo1 adj
Fig. 22
OK
i
LEDs "OK", "i" and "Io L"status versus input voltage
Conditions: Io £ Io nom, TC £ TC max, Uinh £ 0.8 V
i uv = undervoltage lock-out, Ui ov = overvoltage lock-out
Io L
Ui
U
Ui uv Ui min
Ui max Ui ov Ui abs
Uo1 > 0.95...0.98Uo1 adj
Uo1 < 0.95...0.98Uo1 adj
OK
Io L
LEDs "OK" and "Io L"status versus output current
Conditions: Ui min...Ui max, TC £ TC max, Uinh £ 0.8 V
Io
Io nom
IoL
i
i
LED "i"versus case temperature
Conditions: Ui min...Ui max, Io £ Io nom, Uinh £ 0.8 V
TC
TC max
Uinh threshold
TPTC threshold
LED "i"versus Uinh
Conditions: Ui min...Ui max, Io £ Io nom, TC £ TC max
Ui inh
+0.8 V
+2.4 V
+50 V
-50 V
LED off
LED Status undefined
LED on
Test Sockets (Main output only )
Battery Charging/Temperature Sensor
Test sockets for measuring the output voltage Uo1 are lo-
cated at the front of the module. The positive test socket is
protected by a series resistor (see: Functional Description,
block diagrams). The voltage measured at the test sockets
is approximately 30 mV lower than the value measured at
the output terminals.
The LS are intended for lead acid battery charger applica-
tions. For an optimum battery charging and life expectancy
of the battery an external temperature sensor may be con-
nected to the R-input. The sensor is mounted as close as
possible to the battery pole and adjusts the output voltage
of the LS unit according to the temperature of the battery
(which is related to the load of the battery and the ambient
temperature).
In case of double output units externally connected in se-
ries for Uo = 24 V, 30 V or 48 V the monitored output volt-
age is 12 V, 15 V or 24 V respectively.
Depending on the cell voltage and the temperature coeffi-
cient of the battery, different sensor types are available.
For more information please ask Power-One.
Cell voltage [V]
2.40
06123
Uo max
2.35
2.30
Uz = 2.27 V, –3.5 mV/K
2.25
2.20
Uz = 2.23 V, –3.5 mV/K
Uo nom
2.15
[°C]
20 25 30 35 40 45 50
2.10
0
5
10 15
Fig. 17
Dependance of output voltage vs. temperature for defined
temperature coefficient.
Edition 01/01.2001
14/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
Electromagnetic Compatibility (EMC)
A metal oxide VDR together with an input fuse and an input
filter form an effective protection against high input tran-
sient voltages which typically occur in most installations.
The S series has been successfully tested to the following
specifications:
Electromagnetic Immunity
Table 8: Immunity type tests
Phenomenon
Standard 1
Level
Coupling
mode 2
Value
applied
Waveform
Source
imped.
Test
procedure
In
Per-
oper. form. 3
4
Voltage surge
IEC 60571-1
i/c, +i/–i
800 Vp
1500 Vp
3000 Vp
4000 Vp
7000 Vp
1.5 • Ubatt
100 µs
50 µs
5 µs
100 Ω
1 pos. and 1 neg.
voltage surge per
coupling mode
yes
1 µs
100 ns
1 s
4
Supply related
surge
RIA 12
B
+i/–i
0.2 Ω
5 Ω
1 positive
surge
yes
4
Direct transient
C
D
E
F
G
H
J
+i/c, –i/c
960 Vp
1800 Vp
3600 Vp
4800 Vp
8400 Vp
1800 Vp
3600 Vp
4800 Vp
8400 Vp
10/100 µs
5/50 µs
5 pos. and 5 neg.
impulses
yes
0.5/5 µs
0.1/1 µs
0.05/0.1 µs
5/50 µs
100 Ω
Indirect coupled
transient
–o/c, +o/c
0.5/5 µs
0.1/1 µs
0.05/0.1 µs
1/50 ns
K
L
Electrostatic
discharge
(to case)
IEC/EN
61000-4-2
4
contact discharge 8000 Vp
330 Ω
10 positive and
10 negative
discharges
yes
A
air discharge
15000 Vp
Electromagnetic IEC/EN
3
4
antenna
10 V/m
AM 80%
1 kHz
n.a.
80…1000 MHz
yes
yes
A
A
field
61000-4-3
Electromagnetic ENV 50204
field,
pulse modulated
50% duty cycle,
200 Hz repetition
frequency
900 ±5 MHz
Electrical fast
transient/burst
IEC/EN
61000-4-4
capacitive, o/c
2000 Vp bursts of 5/50 ns 50 Ω
1 min positive
1 min negative
transients per
coupling mode
yes
A
A
2.5/5 kHz over
15 ms; burst
period: 300 ms
i/c, +i/–i
direct
4000 Vp
Surge
IEC/EN
61000-4-5
3
4
i/c
+i/–i
2000 Vp
2500 Vp
1.2/50 µs
12 Ω
2 Ω
5 pos. and 5 neg.
surges per
yes
yes
A
A
i/c, +i/–i
10/700 µs
40 Ω
150 Ω
Conducted
disturbances
IEC/EN
61000-4-6
3
i, o, signal wires
10 Vrms
(140 dBµV)
AM 80%
1 kHz
0.15...80 MHz
1 Related and previous standards are referenced in: Technical Information: Standards.
2 i = input, o = output, c = case.
3 A = Normal operation, no deviation from specifications, B = Normal operation, temporary deviation from specs possible.
4 Test in progress, please consult factory.
Note: Previous standards are referenced in: Technical In-
formation: Standards
Edition 01/01.2001
15/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
Electromagnetic Emission
[dBµV]
90
07063
[dBµV/m]
50
07038
A
80
70
60
50
40
30
20
10
0
A
B
40
B
30
20
10
[MHz]
0
MHz
Fig. 23
Fig. 24
Typical disturbance voltage (quasi-peak) at the input accord- Typical radiated electromagnetic field strength (quasi-
ing to CISPR 11/22 and EN 55011/22, measured at
i nom and Io nom
peak) according to CISPR 11/22 and EN 55011/22, nor-
malized to a distance of 10 m, measured at Ui nom and
U
.
Io nom
.
Edition 01/01.2001
16/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
Immunity to Environmental Conditions
Table 9: Environment specifications
Test method
Standard
Test conditions
Status
Ca
Ea
Eb
Fc
Damp heat
steady state
IEC/DIN IEC 60068-2-3
MIL-STD-810D section 507.2 Relative humidity:
Duration:
Temperature:
40 ±2 °C
%
56 days
Unit not
operating
93 +2/-3
Shock
(half-sinusoidal)
IEC/EN/DIN EN 60068-2-27
MIL-STD-810D section 516.3 Bump duration:
Number of bumps:
Acceleration amplitude:
100 gn = 981 m/s2
6 ms
18 (3 each direction)
Unit
operating
Bump
(half-sinusoidal)
IEC/EN/DIN EN 60068-2-29
MIL-STD-810D section 516.3 Bump duration:
Number of bumps:
Acceleration amplitude:
40 gn = 392 m/s2
6 ms
6000 (1000 each direction)
Unit
operating
Vibration
(sinusoidal)
IEC/EN/DIN EN 60068-2-6
Acceleration amplitude:
0.35 mm (10...60 Hz)
5 gn = 49 m/s2 (60...2000 Hz) operating
10...2000 Hz
Unit
Frequency (1 Oct/min):
Test duration:
7.5 h (2.5 h each axis)
Fn
Kb
Vibration
broad band
random
IEC 60068-2-64
DIN 40046 part 23
MIL-STD-810D section 514.3 Acceleration magnitude:
Test duration:
Acceleration spectral density: 0.05 gn2/Hz
Unit
operating
Frequency band:
5...500 Hz
4.97 gn rms
3 h (1 h each axis)
(digital dontrol)
Salt mist, cyclic
(sodium chloride
NaCl solution)
IEC/EN/DIN IEC 60068-2-52
Concentration:
Duration:
Storage:
Storage duration:
Number of cycles:
5% (30°C)
Unit not
operating
2 h per cycle
40°C, 93% rel. humidity
22 h per cycle
3
Table 10: Temperature specifications, values given are for an air pressure of 800...1200 hPa (800...1200 mbar)
Temperature
Standard -7
Option -9
Characteristics
Conditions
min
–25
–25
–40
max
71
min
–40
–40
–55
max
71
Unit
TA Ambient temperature
TC Case temperature
TS Storage temperature
Ui min...Ui max
Io = 0...Io nom
°C
95
95
Not operational
100
100
Table 11: MTBF
Values at Specified
Type
Ground Benign
Ground Fixed
Ground Mobile
Unit
Case Temperature
40°C
40°C
70°C
50°C
MTBF 1
LS 4000/5000
514'000
88'000
38'000
35'000
h
1 Calcualted in accordance with MIL-HDBK217F.
Edition 01/01.2001
17/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
Mechanical Data
Dimensions in mm. Tolerances ±0.3 mm unless otherwise indicated.
European
Projection
7 TE
5 TE
3.27
171.93 (DIN 41494)
50
M4
Measuring point of
case temperature T
C
(+/–)
Test jacks
Option P (U )
o
to
Option D (U
)
Option D (U )
ti
LED i (red)
LED OK (green)
LED IoL (red)
= Ø 3.5
= Ø 4.1
8
152
8
30
60
Front plate
Back plate
Main face
168.5 ±0.5
Note:
– d ≥15 mm, recommended minimum distance to
next part to ensure proper air circulation at full
output power.
– free air locations: the module should be moun-
ted with fins in vertical position to achieve a
maximum air flow through the heat sink.
Fig. 25
Aluminium case S02 with heatsink, black finish and self
cooling, weight: Approx. 1.25 kg
7 TE
3.27
4 TE
50
5
158
M 4
Measuring point of
case temperature TC
5
47.2
17.3
133.4
168 ±0.5
171.93 (DIN 41494)
Note: Long case with option B2, elon-
gated by 60 mm for 220 mm rack depth,
is available on request. (No LEDs, no
test jacks.)
Fig. 26
Aluminium case S02 with option B1 (cooling plate), black
finish and self cooling. Total weight: Approx. 1.15 kg
Edition 01/01.2001
18/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
Safety and Installation Instructions
Installation Instructions
Connector Pin Allocation
The S series AC-DC converters are components, intended
exclusively for inclusion within other equipment by an in-
dustrial assembly operation or by professional installers. In-
stallation must strictly follow the national safety regulations
in compliance with the enclosure, mounting, creepage,
clearance, casualty, markings and segregation require-
ments of the end-use application.
The connector pin allocation table defines the electrical
potentials and the physical pin positions on the H15 con-
nector. Pin no. 24, the protective earth pin present on all LS
AC-DC converters is leading, ensuring that it makes con-
tact with the female connector first.
10002
Connection to the system shall be made via the female con-
nector H15 (see: Accessories). Other installation methods
may not meet the safety requirements.
The AC-DC converters are provided with pin no. 24 ( ),
which is reliably connected with their case. For safety rea-
sons it is essential to connect this pin with the protective
earth of the supply system.
32
4
Type H15
Fig. 27
An input fuse is built-in in the connection from pins no. 30
and 32 (P ) of the unit. Since this fuse is designed to pro-
tect the unit in case of an overcurrent and does not neces-
sarily cover all customer needs, an external fuse suitable
for the application and in compliance with the local require-
ments might be necessary in the wiring to one or both input
potentials, pins nos. 26 and 28 and/or nos. 30 and 32.
View of module’s male H15 connector
Table 12: H15 Connector pin allocation
Pin Connector type H 15
No. LS 4000
LS 5000
Vo2+
Vo2+
Vo2–
Vo2–
Vo1+
Vo1–
R 1
4
Vo1+
Vo1+
Vo1–
Vo1–
S+
Output 1
Output 1
Output 2
Output 2
6
Important: Whenever the inhibit function is not in use,
pin no. 18 (i) should be connected to pin no. 14 (S–/Vo1–)
to enable the output(s).
8
10
12
14
16
18
20
Do not open the modules, or guarantee will be invali-
dated.
Sense
Output 1
Output 1
Control of Uo1
Inhibit
S–
Sense
Due to high current values, all LS units provide two inter-
nally parallel connected contacts for certain paths (pins 4/6,
8/10, 26/28 and 30/32, respectively). It is recommended to
connect load and supply to both female connector pins of
each path in order to keep the voltage drop across the con-
nector pins to an absolute minimum and to not overstress
the connector contacts if currents are higher than
approx. 8 A. The connector contacts are rated 8 A over the
whole temperature range.
R 1
Control of Uo1
Inhibit
i
i
D
Save data
ACFAIL
D
Save data
V 3
22
T
Current sharing
T
Current sharing
Protective earth
24 2
26
Protective earth
Neutral
N
N
P
P
N
N
P
P
Neutral
Phase
Make sure that there is sufficient air flow available for con-
vection cooling. This should be verified by measuring the
case temperature when the unit is installed and operated in
the end-use application. The maximum specified case tem-
perature TC max shall not be exceeded. See also: Thermal
Considerations.
28
30
Phase
32
1 Feature R excludes option P and vice versa
2 Leading pin (pregrounding)
3 Option D excludes option V and vice versa
Check for hazardous voltages before altering any connec-
tions.
Ensure that a unit failure (e.g. by an internal short-circuit)
does not result in a hazardous condition. See also: Safety
of operator accessible output circuit.
Protection Degree
Condition: Female connector fitted to the unit.
IP 30: All units except those with option P, and except
those with option D or V with potentiometer.
Cleaning Agents
IP 20: All units fitted with option P, or with option D or V with
potentiometer.
In order to avoid possible damage, any penetration of
cleaning fluids is to be prevented, since the power supplies
are not hermetically sealed.
Edition 01/01.2001
19/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
Standards and Approvals
All AC-DC converters correspond to class I equipment.
They are UL recognized according to UL 1950, UL recog-
nized for Canada to CAN/CSA C22.2 No. 950-95 and LGA
approved to IEC/EN 60950 standards.
• The use in a pollution degree 2 environment
• The UL 1950 recognition limits the minimum input voltage
to Ui = Ui min + 5 V AC = 90 V AC if the case temperature
exceeds 90°C.
The units have been evaluated for:
• Building in
• Basic insulation between input and case, based on 250 V
AC and 400 V DC
The AC-DC converters are subject to manufacturing sur-
veillance in accordance with the above mentioned UL,
CSA, EN and with ISO 9001 standards.
• Double or reinforced insulation between input and output,
based on 250 V AC and 400 V DC
• Basic insulation between output and case based on
200 V AC and DC
• Operational insulation between output and output
• Connecting the input to a primary or secondary circuit
which is subject to a maximum transient rating of 2500 V
(overvoltage category III based on a 110 V primary cir-
cuit, overvoltage category II based on a 230 V primary
circuit).
Isolation
The electric strength test is performed as factory test in ac-
cordance with IEC/EN 60950 and UL 1950 and should not
be repeated in the field. Power-One will not honour any
guarantee claims resulting from electric strength field tests.
Important: Testing by applying AC voltages will result in
high and dangerous leakage currents flowing through
the Y-capacitors (see fig.: Block diagram).
Table 13: Isolation
Characteristic
Input to
case
Input to Output to Output to
Unit
output
case
output
Electric
strength
test voltage
Required according to
IEC/EN 60950
1.5
2.1
2.8
2.0
3.0 1
–
–
kVrms
4.2 1
–
–
kV DC
Actual factory test 1 s
5.6 1
1.4
1.0
0.14
0.1
AC test voltage equivalent
to actual factory test
4.0 1
kVrms
Insulation resistance at 500 V DC
>300
>300
>300
>100 2
MΩ
1 In accordance with IEC/EN 60950 only subassemblies are tested in factory with this voltage.
2 Tested at 100 V DC.
For creepage distances and clearances refer to: Technical Information: Safety.
Leakage Currents in AC-DC operation
Leakage currents flow due to internal leakage capacitance
and RFI suppression Y-capacitors. The current values are
proportional to the mains voltage and nearly proportional to
the mains frequency and are specified at an input voltage of
254 V (50 Hz) where phase, neutral and protective earth
are correctly connected as required for class I equipment.
Under test conditions the leakage current flows through a
measuring instrument (MI) as described in fig.: Measuring
instrument for earth leakage current tests, which takes into
account impedance and sensitivity of a person touching
unearthed accessible parts. The current value is calculated
by dividing the measured voltage by 500 Ω. If inputs of S-
units are connected in parallel, their individual leakage cur-
rents are added.
1500 Ω
MI
500 Ω
10062
P
Vo+
P
N
N
Vo–
10 kΩ
220 nF
MI for
earth
leakage
current
22 nF
V
Fig. 28
Fig. 29
Measuring instrument (MI) for earth leaking current tests
according to IEC/EN 60950.
Test set-up
Edition 01/01.2001
20/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
Table 14: Leakage currents
Characteristic
Class I
Unit
LS 4000...LS 5000
Maximum earth
leakage current
Permissible according to IEC/EN 60950
Specified value at 254 V, 50 Hz
3.5
mA
0.82
Safety of operator accessible output circuit
If the output circuit of an AC-DC converter is operator ac-
cessible, it shall be an SELV circuit according to the IEC/EN
60950 related safety standards.
to IEC/EN 60950 up to a configured output voltage (sum of
nominal voltages if in series or +/– configuration) of 36 V.
However, it is the sole responsibility of the installer to as-
sure the compliance with the relevant and applicable safety
regulations. More information is given in: Technical Infor-
mation: Safety.
The following table shows a possible installation configura-
tion, compliance with which causes the output circuit of an
S series AC-DC converter to be an SELV circuit according
Table 15: Safety concept leading to an SELV output circuit
Conditions
AC-DC converter
Installation
Result
Nominal voltage
Grade of insulation
between input and output
provided by the AC-DC converter
Measures to achieve the resulting
safety status of the output circuit
Safety status of the AC-DC
converter output circuit
Mains
Double or reinforced
Earthed case 1 and installation
SELV circuit
≤250 V AC
according to the applicable standards
1 The earth connection has to be provided by the installer according to the relevant safety standards, e.g. IEC/EN 60950.
10021
Fuse
+
~
Mains
AC-DC
con-
verter
SELV
Fig. 30
Fuse
–
~
Schematic safety concept. Use fuses and earth connec-
tion as per Installation Instructions and table Safety con-
cept leading to an SELV output circuit.
Earth connection
Description of Options
Table 16: Survey of options
Option
–9
Function of option
Characteristic
Extended operational ambient temperature range
Electronic inrush current limitation circuitry
Potentiometer for fine adjustment of output voltage
Input and/or output undervoltage monitoring circuitry
Input and/or output undervoltage monitoring circuitry
Current sharing
TA = –40...71°C
E
Active inrush current limitation
P 1
Adjustment range +10/-60% of Uo nom, excludes R input
Safe data signal output (D0...DD)
D 2
V 2 3
T
ACFAIL signal according to VME specifications (V0, V2, V3)
Interconnect T-pins if paralleling outputs (5 units max.)
B1, B2
Cooling plate
Replaces standard heat sink, allowing direct chassis-mounting
1 Function R excludes option P and vice versa
2 Option D excludes option V and vice versa
3 Only available if main output voltage Uo1 = 5.1 V
-9 Extended Temperature Range
P Potentiometer
Option –9 extends the operational ambient temperature
range from –25...71°C (standard) to –40...71°C. The power
supplies provide full nominal output power with convection
cooling. Option -9 excludes inrush current limitation by
NTC.
The potentiometer provides an output voltage adjustment
range of +10/–60% of Uo nom and is accessible through a
hole in the front cover. This feature enables compensation
for voltage drops across the connector and wiring. Option P
is not recommended if units are connected in parallel.
Option P excludes the R-function. With double output units
both outputs are affected by the potentiometer setting (dou-
bling the voltage setting if the outputs are in series).
If the output voltages are increased above Uo nom via R-in-
put control, option P setting, remote sensing or option T, the
output current(s) should be reduced accordingly so that
Po nom is not exceeded.
Edition 01/01.2001
21/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
11003
E Inrush Current Limitation
Vo+
The converters may be supplemented by an electronic cir-
cuit (option E, replacing the standard built-in NTC) to
achieve an enhanced inrush current limiting function.
Load
Vo–
Vo+
Table 17: Inrush current characteristics with option E
Vo–
Characteristics
Ui = 230 V AC
LS
Unit
Vo+
typ
–
max
25.3
50
Vo–
Iinr p
tinr
Peak inrush current
Inrush current duration
A
Fig. 33
35
ms
An example of poor wiring for connection in parallel
11011
2
Vo+
N
1
1
Control
S+
T
FET
LS 4000
3
S–
Rectifier
RS
Ci
Vo–
RI
P
N
Load
Fig. 31
2
Vo+
Option E block diagram
S+
T
11002
1
1
Ii [A]
20
3
LS 4000
S–
Capacitor Ci
fully charged
Vo–
P
15
10
5
max. 5 units connected in parallel
1 Leads should have equal length and cross sections and should
run in the same cable loom.
Normal operation
(FET fully conducting)
2 Diodes recommended in redundant operation only
3 DC common point
0
Fig. 34
Paralleling of single output units using option T with the
sense lines connected at the load
–5
–10
Power bus
tinr
10 20 30 40 50 60 70 80
+
–
t [ms]
Vo2+
0
Vo2–
Fig. 32
T
Inrush current with option E, Ui = 230 V AC, Po = Po nom
11037
Module
Vo1+
Precaution:
Vo1–
Subsequent switch-on cycles at start-up are limited to
max. 10 cycles during the first 20 seconds (cold unit)
and at continuing on/off (TC = 95°C) max. 1 cycle every
8 sec.
Load
Vo2+
Vo2–
T
T Current Sharing
Module
This option ensures that the output currents are approxi-
mately shared between all paralleled modules and in-
creases system reliability. To use this facility, simply inter-
connect the T pins of all modules and make sure, that
pin 14, the S– pin (S 4000) or the Vo1– pins (S 5000) are
also connected together. The load leads should have equal
length and cross section to ensure equal voltage drops. Not
more than 5 units should be connected in parallel. If output
voltage adjustment is requested we strongly recommend to
use the R-input instead of option P, as with option P the re-
quired setting accuracy is difficult to achieve. The output
voltages must be individually set prior to paralleling to
within a tolerance of 1...2% or the R pins should be con-
nected together.
Vo1+
Vo1–
max. 5 units in parallel connection
Fig. 35
Paralleling of double output units using option T with
Power bus.
Edition 01/01.2001
22/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
D Undervoltage Monitor
threshold level Uti is adjusted in the factory. The threshold
level Uto is either adjusted by a potentiometer, accessible
through a hole in the front cover, or factory adjusted to a
fixed value specified by the customer.
The input and/or output undervoltage monitoring circuit op-
erates independently of the built-in input undervoltage lock-
out circuit. A logic "low" (JFET output) or "high" signal (NPN
output) is generated at pin 20 as soon as one of the moni-
tored voltages drops below the preselected threshold level
Ut. The return for this signal is Vo1–. The D output recovers
when the monitored voltage(s) exceed(s) Ut + Uh. The
Option D exists in various versions D0...DD as shown in the
following table.
Table 18: Undervoltage monitoring functions
Output type
Monitoring
Minimum adjustment range
of threshold level Ut
Uti Uto
Typical hysteresis Uho [% of Ut]
JFET
NPN
Ui
Uo1
for Ut min...Ut max
Uho
D1
D2
D3
D4
D0
D5
D6
D7
D8
D9
no
yes
yes
no
yes
no
-
3.5...40 V 1
-
2.5...0.6
-
355V DC 4
2
2
yes
yes
yes
yes
355V DC 4
(0.95...0.985 Uo1
(0.95...0.985 Uo1
3.5...40 V 3
3.5...40 V 3
)
)
"0"
-
"0"
no
-
2.5...0.6
2.5...0.6
yes
355V DC 4
DD
yes
yes
355V DC 4
3.5...40 V 1
2.5...0.6
1 Threshold level adjustable by potentiometer
2 Fixed value. Tracking if Uo1 adjusted via R-input, option P or sense lines.
3 The threshold level permanently adjusted according to customer specification ±2% at 25°C. Any value within the specified range is
basically possible but causes a special type designation in addition to the standard option designations (D0/D9)!
4 Option D monitors the boost regulator output voltage. The trigger level is adjusted in the factory to 355 V DC.
11006
JFET output (D0…D4):
Vo1+
Connector pin D is internally connected via the drain-
source path of a JFET (self-conducting type) to the nega-
tive potential of output 1. UD ≤ 0.4 V (logic low) corresponds
to a monitored voltage level (Ui and/or Uo1) <Ut. The cur-
rent ID through the JFET should not exceed 2.5 mA. The
JFET is protected by a 0.5 W Zener diode of 8.2 V against
external overvoltages.
R
p
I
D
D
U
D
Ui, Uo1 status
Ui or Uo1 < Ut
D output, UD
Vo1–
low, L, UD ≤ 0.4 V at ID = 2.5 mA
high, H, ID ≤ 25 µA at UD = 5.25 V
Fig. 36
Ui and Uo1 > Ut + Uh
Option D0...D4: JFET output, ID ≤ 2.5 mA
11007
Vo1+
NPN output (D5...DD):
Connector pin D is internally connected via the collector-
emitter path of a NPN transistor to the negative potential of
output 1. UD < 0.4 V (logic low) corresponds to a monitored
voltage level (Ui and/or Uo1) > Ut + Uh. The current ID
through the open collector should not exceed 20 mA. The
NPN output is not protected against external overvoltages.
UD should not exceed 40 V.
R
p
I
D
D
U
D
Ui, Uo1 status
Ui or Uo1 < Ut
D output, UD
Vo1–
high, H, ID ≤ 25 µA at UD = 40 V
low, L, UD ≤ 0.4 V at ID = 20 mA
Fig. 37
Option D5...DD: NPN output, Uo1 ≤ 40 V, ID ≤ 20 mA
Ui and Uo1 > Ut + Uh
Table 19: D-output logic signals
Version of D
Ui < Ut resp. Uo < Ut
Ui > Ut + Uh resp. Uo > Ut
Configuration
JFET
D1, D2, D3, D4, D0
D5, D6, D7, D8, D9, DD
low
high
low
high
NPN
Edition 01/01.2001
23/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
D-signal with respect to input and output voltage versus time:
Input voltage monitoring
NPN
UD
11044
UD high
3
3
3
3
UD low
0
t
ID
ID high
ID low
0
t
JFET UD
UD high
UD low
0
t
1
4
4
4
th
tlow min
tlow min
tlow min
thigh min
Uo1
Uo1 nom
1
th
1
0.95
t
t
0
Uci [V DC]
358
355
0
Input voltage failure
Switch-on cycle
Input voltage sag
Switch-on cycle and subsequent
input voltage failure
Output voltage monitoring
NPN UD
2
UD high
UD low
0
t
t
ID
ID high
ID low
0
UD
JFET
UD high
UD low
0
t
t
4
tlow min
1 Hold-up time see section Electrical Input Data.
2 With output voltage monitoring, hold-up time th = 0.
3 The signal will remain high if the D output is connected to
an external source.
Uo1
Uo1 nom
Uto +Uho
Uto
4 tlow min = 100...170 ms, typically 130 ms.
0
Output voltage failure
Fig. 38
Relationship between Uci, Uo1, UD, Uo1/Uo nom versus time
Edition 01/01.2001
24/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
V ACFAIL Signal (VME)
V output (V2, V3):
Available for units with Uo1 = 5.1V
Connector pin V is internally connected to the open collec-
tor of a NPN transistor. The emitter is connected to the
negative potential of output 1. UV ≤ 0.6 V (logic low) corre-
sponds to a monitored voltage level (Ui and/or Uo1) <Ut.
The current IV through the open collector should not ex-
ceed 50 mA. The NPN output is not protected against ex-
ternal overvoltages. UV should not exceed 60 V.
This option defines an undervoltage monitoring circuit for
the input or input and main output voltage equivalent to op-
tion D and generates the ACFAIL signal (V signal) which
conforms to the VME standard.
The low state level of the ACFAIL signal is specified at a
sink current of IV ≤ 48 mA to UV ≤ 0.6 V (open-collector out-
put of a NPN transistor). The pull-up resistor feeding the
open-collector output should be placed on the VME back
plane.
Ui, Uo1 status
Ui or Uo1 < Ut
V output, UV
low, L, UV ≤ 0.6 V at IV = 50 mA
high, H, IV ≤ 25 µA at UV = 5.1 V
After the ACFAIL signal has gone low, the VME standard
requires a hold-up time th of at least 4 ms before the 5.1 V
output drops to 4.875 V when the output is fully loaded.
This hold-up time th is provided by the internal input capaci-
tance. See also fig.: Hold-up Time versus Output Power.
Ui and Uo1 > Ut + Uh
11009
Vo1+
Table 20: Undervoltage monitor functions
R
p
I
V output
Monitoring
Minimum adjustment
V
(VME compatible)
Ui
Uo1
range of threshold level
V
Uti
no 355V DC 1
Uto
U
V
–
V2
V3
yes
yes
2
yes 355V DC 1 0.95...0.985 Uo1
Vo1–
1 Option D monitors the boost regulator output voltage. The trig-
ger level is adjusted in the factory to 355 V DC.
Fig. 39
Output configuration of options V2 and V3
2 Fixed value between 95% and 98.5% of Uo1
.
Option V operates independently of the built-in input under-
voltage lock-out circuit. A logic "low" signal is generated at
pin 20 as soon as one of the monitored voltages drops be-
low the preselected threshold level Ut. The return for this
signal is Vo1–. The V output recovers when the monitored
voltage(s) exceed(s) Ut + Uh. The threshold level Uti is ad-
justed in the factory to 355 V DC. The threshold level Uto
either is adjusted during manufacture to a determined cus-
tomer specified value.
Edition 01/01.2001
25/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
11045
Input voltage monitoring
2
2
2
tlow min
tlow min
tlow min
V2
UV
3
3
3
UV high
4
2
4
2
UV low
t
0
tlow min
tlow min
V3
UV
3
3
3
UV high
UV low
t
0
1
1
th
th
Uo1
5.1 V
4.875 V
2.0 V
0
t
Uci [V DC]
358
355
t
0
Input voltage failure
Switch-on cycle
Input voltage sag
Switch-on cycle and subsequent
input voltage failure
Output voltage monitoring
V2 UV
UV high
4
4
UV low
t
t
0
2
tlow min
V3 UV
UV high
3
3
4
UV low
0
Uo1
5.1 V
4.875 V
2.0 V
0
t
1 VME request: minimum 4 ms
2 tlow min = 40...200 ms, typically 80 ms
3 UV level not defined at Uo1 < 2.0 V
Ui
4 The V signal drops simultaneously with the output voltage if the
pull-up resistor RP is connected to Vo1+.
The V signal remains high if RP is connected to an external
source.
Uti + Uhi
Uti
t
0
Output voltage failure
Fig. 40
Relationship between Uci, Uo1, UV, IV and Uo1/Uo nom ver-
sus time.
Edition 01/01.2001
26/27
Cassette Style
100 Watt AC-DC Converters
S Series PFC
B1 Cooling Plate (see: Mechanical Data)
Where a cooling surface is available, we recommend the
use of a cooling plate (option B1) instead of the standard
heatsink. The mounting system should ensure sufficient
cooling capacity to guarantee that the maximum case tem-
perature TC max is not exceeded. The cooling capacity is cal-
culated by:
(100% – h)
PLoss = –––––––––– (Uo • Io)
h
Efficiency η see: Type survey.
Elongated case for 220 mm rack depth: Option B2.
Accessories
A variety of electrical and mechanical accessories are
available including:
– Front panels for 19" rack mounting, Schroff and Intermas
systems.
– Mating H15 connectors with screw, solder, fast-on or
press-fit terminals.
– Connector retention facilities.
– Code key system for connector coding.
– Chassis mounting plates for mounting the 19" cassette to
a chassis/wall where only frontal access is given.
– Universal mounting bracket for DIN-rail or chassis moun-
ting.
For more detailed information please refer to: Accessory
Products.
Front panels
H15 female connector,
Code key system
Chassis mounting bracket S
Mounting plate,
Connector retention clips
Universal mounting bracket for DIN-rail mounting.
Edition 01/01.2001
27/27
相关型号:
LS4001-7EPD8T
AC-DC Power Factor Correction Module, 1 Output, 100W, HEAT SINK, METAL, CASE S02, MODULE
BEL
LS4001-7EPD9B1
AC-DC Power Factor Correction Module, 1 Output, 100W, Hybrid, METAL, CASE S02, MODULE
BEL
LS4001-7EPD9B2
AC-DC Power Factor Correction Module, 1 Output, 100W, Hybrid, METAL, CASE S02, MODULE
BEL
LS4001-7EPD9TB1
AC-DC Power Factor Correction Module, 1 Output, 100W, Hybrid, METAL, CASE S02, MODULE
BEL
LS4001-7EPDD
AC-DC Power Factor Correction Module, 1 Output, 100W, Hybrid, HEAT SINK, METAL, CASE S02, MODULE
BEL
LS4001-7EPTB1
AC-DC Power Factor Correction Module, 1 Output, 100W, Hybrid, METAL, CASE S02, MODULE
BEL
LS4001-7EPV2B1
AC-DC Power Factor Correction Module, 1 Output, 100W, Hybrid, METAL, CASE S02, MODULE
BEL
LS4001-7EPV2B2
AC-DC Power Factor Correction Module, 1 Output, 100W, Hybrid, METAL, CASE S02, MODULE
BEL
LS4001-7EPV2T
AC-DC Power Factor Correction Module, 1 Output, 100W, HEAT SINK, METAL, CASE S02, MODULE
BEL
LS4001-7EPV3B1
AC-DC Power Factor Correction Module, 1 Output, 100W, Hybrid, METAL, CASE S02, MODULE
BEL
LS4001-7EPV3TB2
AC-DC Power Factor Correction Module, 1 Output, 100W, Hybrid, METAL, CASE S02, MODULE
BEL
©2020 ICPDF网 联系我们和版权申明