BQ2660-7R [BEL]

DC-DC Regulated Power Supply Module,;
BQ2660-7R
型号: BQ2660-7R
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

DC-DC Regulated Power Supply Module,

文件: 总31页 (文件大小:4185K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Q Series  
66 - 132 Watt DC-DC Converters  
Features  
• RoHS lead-free-solder and lead-solder-exempted products  
are available  
• 5 year warranty for RoHS compliant products with an  
extended temperature range  
• Class I equipment  
• Compliant with EN 45545 (version V106 or later)  
• Wide input voltage ranges up to 154 VDC  
• 1 or 2 isolated outputs from 3.3 to 24 V  
• Flexible output power  
Extremely high efficiency of up to 90%  
• Excellent surge and transient protection  
• Outputs open and short-circuit proof  
• Redundant operation, current sharing  
• Extremely low inrush current, hot-swappable  
• Externally adjustable output voltage and inhibit  
• Electric strength test 2.1 kVDC  
• Extremely slim case (4 TE, 20 mm), fully enclosed  
111  
4.4ꢀ  
3 U  
Safety-approved to the latest edition of IEC/EN 60950-1  
and UL/CSA 60950-1  
164  
6.5ꢀ  
20  
0.8ꢀ  
4 TE  
1
1
on request  
Table of Contents  
Description........................................................................................2  
Model Selection................................................................................2  
Functional Description......................................................................6  
Electrical Input Data .........................................................................7  
Electrical Output Data.......................................................................9  
Auxiliary Functions .........................................................................18  
Electromagnetic Compatibility (EMC).............................................22  
Immunity to Environmental Conditions...........................................24  
Mechanical Data.............................................................................26  
Safety and Installation Instructions.................................................27  
Description of Options....................................................................29  
Accessories....................................................................................31  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
Q Series  
66 - 132 W DC-DC Converters  
Description  
These extremely compact DC-DC converters incorporate all necessary input and output filters, signaling and protection features,  
which are required in the majority of applications. The converters provide important advantages such as flexible output power  
through primary current limitation, high efficiency, excellent reliability, very low ripple and RFI noise levels, full input to output  
isolation, negligible inrush current, overtemperature protection, and input over-/undervoltage lockout.  
The converter inputs are protected against surges and transients occurring on the source lines.  
The converters are particularly suitable for rugged environment, such as railway applications. They have been designed in  
accordance with the European railway standards EN 50155 and EN 50121-3-2. All printed circuit boards are coated with a  
protective lacquer.  
The outputs are continuously open- and short-circuit proof. An isolated output Power Good signal and LEDs at the front panel  
indicate the status of the converter. Test sockets at the front panel allow for a check of the main output voltage.  
Full system flexibility and n+1 redundant operating mode are possible due to virtually unrestricted series or parallel connection  
capabilities of all outputs. In parallel connection of several converters, automatic current sharing is provided by a single-wire  
interconnection.  
As a modular power supply or as part of a distributed power supply system, the extremely low-profile design reduces the necessary  
power supply volume without sacrificing high reliability. A temperature sensor disables the outputs when the case temperature  
exceeds the limit. The outputs are automatically re-enabled, when the temperature drops.  
The fully enclosed, black-coated aluminum case acts as a heat sink and an RFI shield. The converters are designed for 19" DIN-  
rack systems occupying 3 U/4 TE only, but can also be chassis-mounted by four screws. Fitting an additional heat sink or ordering  
options with fitted heat sink is possible as well.  
Model Selection  
Table 1a: Model Selection BQ, GQ  
Output 1  
Output 2  
Output power1  
Operating input voltage range, efficiency  
Options  
TA= 71°C TA= 50°C  
2
2
Vo nom Io nom Io max Vo nom Io nom Io max  
Po nom  
Po max  
Vi min - Vi max  
ηmin  
ηtyp  
Vi min - Vi max  
ηmin  
[%]  
ηtyp  
[VDC]  
3.3  
[A]  
20  
16  
8
[A] [VDC] [A]  
[A]  
[W]  
[W]  
14.4 - 36 VDC  
[%]  
81  
85  
87  
87  
88  
85  
87  
87  
89  
[%]  
21.6 - 54 VDC  
[%]  
25  
20  
10  
8
-
-
-
-
-
-
66  
82  
82  
BQ1101-9G  
GQ1101-9G  
-7, B, B1, non-G  
5.1  
102  
120  
120  
132  
97  
BQ1001-9RG  
BQ2320-9RG  
BQ2540-9RG  
BQ2660-9RG  
BQ2001-9RG  
BQ2320-9RG  
BQ2540-9RG  
BQ2660-9RG  
86  
GQ1001-9RG 85.5  
87  
GQ2540-9RG 86.5  
90.5 GQ2660-9RG 88  
86 GQ2001-9RG 85.5  
88.5 GQ2320-9RG 87  
89 GQ2540-9RG 86.5  
90.5 GQ2660-9RG 88  
86  
89  
12 3  
15 3  
24 3  
5.1 4  
12 4  
15 4  
24 4  
-
-
-
96  
88.5 GQ2320-9RG  
89  
-7, P, F, B, B1, non-G  
-7, F, B, B1, non-G  
6.6  
4.4  
7.5  
4
-
-
-
99  
88.5  
90  
5.5  
8.5  
5
-
-
-
106  
77  
5.1 4  
12 4  
15 4  
24 4  
7.5  
4
8.5  
5
4
86  
96  
120  
120  
132  
89  
3.3  
2.2  
4
3.3  
99  
88.5 -7, P, F, B, B1, non-G  
2.75  
2.2 2.75  
106  
90  
1
The cumulated power of both outputs cannot exceed the total power for the specified ambient temperature.  
See also Output Power at Reduced Temperature.  
Minimum efficiency at Vi nom, Io nom and TA = 25 °C  
Double-output models with both outputs connected in parallel  
Double-output models. The isolated output 2 is a tracking output 1.  
2
3
4
NFND: Not for new designs.  
Preferred for new designs  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 2 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Table 1b: Model Selection CQ, 48Q  
Output 1  
Output 2  
Output power1  
Operating input voltage range, efficiency  
Options  
TA= 71°C TA= 50°C  
2
2
Vo nom Io nom Io max Vo nom Io nom Io max  
Po nom  
Po max  
Vi min - Vi max  
ηmin  
ηtyp  
Vi min - Vi max  
ηmin  
[VDC]  
3.3  
[A]  
20  
16  
16  
8
[A] [VDC] [A]  
[A]  
[W]  
[W]  
33.6 - 75 VDC  
[%]  
[%]  
38.4 - 75 VDC  
[%]  
25  
20  
-
-
-
-
-
-
66  
82  
-
82  
102  
82  
CQ1101-9G  
82  
85  
-7, P, F, B, B1, non-G  
5.1  
-
-
CQ1001-9RG  
87  
89.5  
90  
-7, P, F, B, B1, non-G  
5.1  
-
-
48Q1001-2R  
48Q2320-2R  
48Q2540-2R  
48Q2660-2R  
83  
85  
85  
87  
-
12 3  
12 3  
15 3  
15 3  
24 3  
24 3  
5.1 4  
12 4  
12 4  
15 4  
15 4  
24 4  
24 4  
10  
-
-
-
-
96  
-
120  
96  
CQ2320-9RG  
88  
-7, P, F, B, B1, non-G  
8
-
-
-
-
6.6  
6.6  
4.4  
4.4  
7.5  
4
8
-
-
-
99  
-
120  
99  
CQ2540-9RG 88.5  
CQ2660-9RG 88.5  
-7, P, F, B, B1, non-G  
-
-
-
-
-
5.5  
-
-
-
-
106  
-
132  
106  
97  
90.5  
-7, P, F, B, B1, non-G  
-
-
-
-
8.5  
5
5.1 4  
12 4  
12 4  
15 4  
15 4  
24 4  
24 4  
7.5  
4
8.5  
5
-
77  
96  
-
CQ2001-9RG  
CQ2320-9RG  
85  
87  
87  
88  
-7, P, F, B, B1, non-G  
120  
96  
-7, P, F, B, B1, non-G  
4
-
4
48Q2320-2R  
48Q2540-2R  
48Q2660-2R  
85  
85  
87  
-
3.3  
3.3  
2.2  
2.2  
4
3.3  
3.3  
2.2  
2.2  
4
-
99  
-
120  
99  
CQ2540-9RG 88.5  
CQ2660-9RG 88.5  
90  
90  
-7, P, F, B, B1, non-G  
-
-
2.7  
-
2.7  
-
106  
-
132  
106  
-7, P, F, B, B1, non-G  
-
Table 1c: Model Selection DQ, EQ  
Output 1  
Output 2  
Output power1  
Operating input voltage range, efficiency  
Options  
TA= 71°C TA= 50°C  
2
2
Vo nom Io nom Io max Vo nom Io nom Io max  
Po nom  
Po max  
Vi min - Vi max  
ηmin  
ηtyp  
Vi min - Vi max  
ηmin  
ηtyp  
[VDC]  
3.3  
[A]  
20  
16  
8
[A] [VDC] [A]  
[A]  
[W]  
[W]  
43 - 108 VDC  
[%]  
[%]  
66 - 150 VDC  
[%]  
[%]  
25  
20  
10  
8
-
-
-
-
-
-
66  
82  
82  
DQ1101-9G  
82*  
EQ1101-9G  
-7, B, B1, non-G  
5.1  
102  
120  
120  
132  
97  
DQ1001-9RG 85.5  
86.5 EQ1001-9RG  
90 EQ2320-9RG  
85  
87  
86  
89  
89  
89  
86  
89  
89  
89  
12 3  
15 3  
24 3  
5.1 4  
12 4  
15 4  
24 4  
-
-
-
96  
DQ2320-9RG  
DQ2540-9RG  
DQ2660-9RG  
DQ2001-9RG  
DQ2320-9RG  
DQ2540-9RG  
DQ2660-9RG  
88  
89  
89  
85  
88  
89  
89  
-7, P, F, B, B1, non-G  
6.6  
4.4  
7.5  
4
-
-
-
99  
90.5 EQ2540-9RG 87.5  
90 EQ2660-9RG 87.5  
86.5 EQ2001-9RG  
90 EQ2320-9RG  
5.5  
8.5  
5
-
-
-
106  
77  
5.1 4  
12 4  
15 4  
24 4  
7.5  
4
8.5  
5
4
84  
87  
-7, B, B1, non-G  
96  
120  
120  
132  
3.3  
2.2  
4
3.3  
99  
90.5 EQ2540-9RG 87.5  
90 EQ2660-9RG 87.5  
-7, P, F, B, B1, non-G  
2.75  
2.2 2.75  
106  
1
The cumulated power of both outputs cannot exceed the total power for the specified ambient temperature.  
See also Output Power at Reduced Temperature.  
Minimum efficiency at Vi nom, Io nom and TA = 25 °C  
Double-output models with both outputs connected in parallel  
Double-output models. The isolated output 2 is a tracking output 1.  
2
3
4
NFND: Not for new designs.  
Preferred for new designs  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 3 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Part Number Description  
C Q 2 5 40 -9 R B1 G  
Input voltage Vi nom  
:
24 V ..................................................................... B  
36 V ......................................................................G  
48 V ......................................................................C  
48 V (Telecom, NFND)........................................ 48  
72 V ......................................................................D  
110 V.....................................................................E  
..............................................................................Q  
Series  
Number of outputs:  
Single output models ............................................ 1  
Double output models .......................................... 2  
Single output models (long case) 2 ....................... 6  
Double output models (long case) 2...................... 7  
Nominal voltage of main output:  
3.3 V ..................................................................... 1  
5.1 V ..................................................................... 0  
12 V ...................................................................... 3  
15 V ...................................................................... 5  
24 V .................................................................. 6, 7  
Other voltages .............................................. 7, 8, 9  
Other specifications and additional features  
for single output models 3 ............................01 - 99  
Nominal voltage of output 2, Vo2 nom  
:
5.1 V ............................................................01 - 09  
12 V .............................................................20 - 39  
15 V .............................................................40 - 59  
24 V .............................................................60 - 79  
Other voltages and additional features5 ...... 01 - 99  
Operational ambient temperature range TA:  
10 to 50 °C (NFND) ...........................................-2  
25 to 71 °C (option, NFND) ...............................-7  
40 to 71 °C ........................................................-9  
other3 ....................................................... -0, -5, -6  
Output voltage adjust (auxiliary function) ................................R  
1
Options: Potentiometer (option, NFND) ............................P  
No fuse (option) ....................................................F  
Additional heatsink ........................................ B, B1  
RoHS-compliant for all 6 substances ......................................G  
1
Option P excludes feature R and vice versa.  
Models with 220 mm case length. Just add 5000 to the standard model number, e.g., CQ2540-9RG → CQ7540-9RG.  
Customer-specific models.  
2
3
Note: The sequence of options must follow the order above. This part number description is not intended for creating part numbers.  
NFND: Not for new designs. Preferred for new designs  
Example: CQ2540-9RB1G: DC-DC converter, input voltage range 33.6 to 75V, double-output model, each output providing  
15 V/3.3 A, equipped with a heat sink, operating ambient temperature TA = 40 to 71 °C, RoHS-compliant for all six substances.  
Note: All models have the following auxiliary functions, which are not shown in the type designation: input and output filter, inhibit, sense lines,  
current sharing, Out OK signal, LED indicators, and test sockets (not 48Q models).  
Note: 48Q models are designed according to Telecom standards ETS 300132-2 and EN 41003. Vi min is 38.4 V, such limiting the input current  
Ii to 150% of Ii nom  
.
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 4 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Product Marking  
Type designation, applicable safety approval and recognition marks, CE mark, warnings, pin allocation, patents, and company logo.  
Identification of LEDs, test sockets and potentiometer.  
Input voltage range and input current, nominal output voltages and currents, degree of protection, batch no., serial no., and data  
code including production site, version (modification status) and date of production.  
Output Configuration  
The Q Series design allows different output configurations to cover almost every individual requirement, by simply wiring the  
outputs in parallel, series, or symmetrical configuration as per the following figures. For further information and for parallel and  
series operation of several converters see Electrical Output Data.  
01002a  
01001a  
Single-output  
model  
Double-output  
model  
4
6
6
4
Voꢀ  
Voꢀ  
Vo2ꢀ  
Vo1ꢀ  
Sꢀ  
12  
14  
8
28  
30  
Sꢀ  
S–  
28  
30  
12  
14  
8
i
i
Load  
Load  
Viꢀ  
S–  
Viꢀ  
32 Vi–  
Vo–  
Vo–  
32 Vi–  
Vo1–  
10  
Vo2– 10  
Fig. 1  
Fig. 2  
Parallel-output configuration  
Single-output configuration  
01003a  
01004a  
Double-output  
model  
Double-output  
model  
6
10  
4
Vo1ꢀ  
Voꢀ  
Vo2ꢀ  
Vo2–  
Vo1ꢀ  
Sꢀ  
4
12  
14  
8
Sꢀ  
S–  
Load 1  
28  
30  
i
28  
i
Viꢀ  
Vo1–  
Vo2ꢀ  
Vo2–  
GND  
Load 2  
Vo–  
12  
30 Viꢀ  
Load  
32 Vi–  
6
Vi–  
S– 14  
32  
10  
Vo1–  
8
Fig. 3  
Series-output configuration  
Fig. 4  
Symmetrical-output configuration (with common ground)  
01005a  
Double-output  
model  
Vo1ꢀ  
4
12  
Sꢀ  
Load 1  
Load 2  
28  
30  
32  
S– 14  
i
Vo1–  
8
6
Viꢀ  
Vi–  
Vo2ꢀ  
Vo2–  
10  
Fig. 5  
Independent-output configuration  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 5 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Functional Description  
The converters are designed as forward converters using primary and secondary control circuits in SMD technology. The switching  
frequency is approximately 200 kHz under nominal operating conditions. The built-in high-efficient input filter together with a small  
input capacitance generate very low inrush currents of short duration. After transformer isolation and rectification, the output filter  
reduces ripple and noise to a minimum without compromising the dynamic ability. The output voltage is fed to the secondary control  
circuit via separate sense lines. The resultant error signal is sent to the primary control circuit via a signal transformer.  
Double-output models have the voltage regulation of output 2 relying on the close magnetic coupling of the transformer and the output  
inductor together with the circuits' symmetry.  
The current limitation is located at the primary side, thus limiting the total output current in overload conditions. This allows flexible  
loading of each output for unsymmetrical loads in the range 10 to 90% of the total output power. In applications with large dynamic  
load changes, we recommend connecting such a load to output 1. If output 2 is not used, it should be connected parallel to output 1.  
Both outputs can either be series- or parallel-connected (see Electrical Output Data).  
In normal operation, the internal control circuits are powered by a third winding of the main choke (except 48Q models). Start-up is  
ensured from the input voltage by a linear regulator.  
Note: When the output voltage is much lower then the nominal value, this linear regulator is activated, generating considerable power losses.  
03111a  
2
22  
24  
18  
Out OKꢀ  
Out OK–  
T
Output  
control  
Primary  
control circuit  
28  
i
Output  
monitor  
16 R3  
Sꢀ1  
12  
4
6
Viꢀ 30  
Voꢀ  
Voꢀ  
Input  
filter  
Output  
filter  
Vi–  
8
32  
26  
Vo–  
Vo–  
S–1  
Fuse  
10  
14  
1
Cy  
Cy  
Isolation  
20  
4
1 Leading pins  
2 Potentiometer for option P 3 Do not connect for models xQ1101 or with option P 4 Do not connect  
Fig. 6  
Block diagram of a single-output converter  
03112a  
2
22  
Out OKꢀ  
Out OK–  
T
24  
18  
16  
Output  
control  
Primary  
control circuit  
28  
i
Output  
monitor Vo2  
R3  
6
Vo2ꢀ  
Output  
filter  
Viꢀ 30  
10 Vo2–  
Input  
filter  
Sꢀ1  
12  
Vo1ꢀ  
4
Vi–  
32  
26  
Fuse  
Output  
filter  
Cy  
1
8
Vo1–  
S–1  
14  
Cy  
Isolation  
20  
4
1 Leading pins  
2 Potentiometer for option P 3 Do not connect for models with option P 4 Do not connect  
Fig. 7  
Block diagram of a double-output converter  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 6 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Electrical Input Data  
General conditions:  
- TA = 25 °C, unless TC is specified.  
- Sense lines connected directly at the connector, inhibit (28) connected to Vi(32).  
- R-input not connected; with option P, Vo set to Vo nom at Vi nom  
.
Table 2a: Input data  
Model  
BQ  
GQ  
CQ  
Unit  
Characteristics  
Conditions  
min  
typ  
max  
min  
typ  
max  
min  
typ  
max  
14.4  
36  
21.6  
54  
33.6  
75  
Vi Operating input voltage cont. Io = 0 – Io max,TC min TC max  
24  
36  
48  
Vi nom Nominal input voltage  
Vi abs Input voltage limits  
V
0
50  
0
63  
0
100  
3 s, without damage  
4.5  
3.0  
2.2  
Ii  
Typical input current 1  
Vi nom, Io nom  
A
W
A
2.5  
1.0  
3.0  
1.5  
2.5  
1.5  
Pi 0  
No-load input power  
Vi min Vi max, Io = 0  
Pi inh Idle input power 4  
55  
50  
130  
5
40  
40  
110  
5
35  
35  
80  
8
Iinr p  
tinr r  
tinr h  
ton  
Peak inrush current 2  
Rise time inrush  
Time to half value  
Start-up time 3  
Vi nom, Io nom  
μs  
ms  
0Vi min, Io nom  
Table 2b: Input data  
Model  
48Q2  
DQ  
EQ  
Unit  
Characteristics  
Conditions  
min  
typ  
max  
min  
typ  
max  
min  
typ  
max  
38.4  
75  
43  
108  
66  
150  
154  
Vi  
Operating input voltage cont.  
for ≤ 2 s, without lockout  
Io = 0 – Io max  
TC min TC max  
Vi 2s  
V
482  
2.2  
72  
110  
1.0  
Vi nom Nominal input voltage  
Vi abs Input voltage limits  
0
100  
0
125  
0
200  
3 s, without damage  
Ii  
Typical input current 1  
Vi nom, Io nom  
A
W
A
1.5  
2.5  
1.5  
5.5  
3.5  
5.0  
3.5  
Pi 0  
No-load input power  
Vi min Vi max, Io = 0  
Pi inh Idle input power 4  
Iinr p  
tinr r  
tinr h  
ton  
Peak inrush current 2  
Rise time inrush  
Time to half value  
Start-up time 3  
35  
35  
80  
8
20  
50  
90  
20  
45  
15  
25  
20  
Vi nom, Io nom  
μs  
ms  
0Vi min, Io nom  
1
2
3
4
Typical input current depends on model type  
According to ETS 300132-2  
See fig. 19  
Converter inhibited  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 7 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Input Fuse  
An incorporated fuse in series to the negative input line protects against severe defects. The fuse is not externally accessible.  
Reverse polarity at the input will cause the fuse to blow.  
Note: For models with no internal fuse, see opt. F. The customer must provide an appropriate external fuse or circuit breaker.  
Model  
BQ  
Fuse type  
Reference and rating  
very fast acting  
very fast acting  
very fast acting  
very fast acting  
very fast acting  
very fast acting  
2x Littelfuse 251, 10 A, 125 V  
2x Littelfuse 251, 7 A, 125 V  
Littelfuse 251, 10 A, 125 V  
Littelfuse 251, 10 A, 125 V  
Littelfuse 251, 7 A, 125 V  
Littelfuse 263, 5 A, 250 V  
GQ  
CQ  
48Q  
DQ  
EQ  
Input Transient Protection  
Ametal oxide VDR (Voltage Dependent Resistor) together with the input fuse and a symmetrical input filter form an effective protection  
against high input transient voltages, which typically occur in most installations, especially in battery-driven mobile applications.  
Nominal battery voltages in use are: 24, 36, 48, 72, 96, and 110 V. In most cases each nominal value is specified in a tolerance  
band of –30% to +25%, with short excursions to ±40% or even more.  
In some applications, surges according to RIA12 are specified in addition to those defined in IEC60571-1 or EN 50155. The power  
supply must not switch off during these surges, and since their energy can practically not be absorbed, an extremely wide input  
voltage range is required. The Q Series input ranges have been designed and tested to meet most of these requirements. See  
also Electromagnetic Immunity.  
Input Under-/Overvoltage Lockout  
If the input voltage falls outside the limits of Vi, an internally generated inhibit signal disables the output(s).  
Inrush Current  
The inherent inrush current value is lower than specified in the standard ETS 300132-2. The converters operate with relatively  
small input capacitance Ci (see table 4), resulting in low inrush current of short duration. As a result, in a power-bus system the  
converters can be hot-swapped, causing negligible disturbances.  
Input Stability with Long Supply Lines  
If a converter is connected to the power source by long supply lines exhibiting a considerable inductance Lext, an additional external  
capacitor Cext connected across the input pins improves the stability and prevents oscillations.  
Actually, a Q Series converter with its load acts as negative resistor ri, because the input current Ii rises, when the input voltage Vi  
decreases. It tends to oscillate with a resonant frequency determined by the line inductance Lext and the input capacitance Ci + Cext,  
damped by the resistor Rext. The whole system is not linear at all and eludes a simple calculation. One basic condition is given by  
the formula:  
Lext Po max  
dVi  
___  
_________  
Ci + Cext  
>
( ri =  
)
Rext Vi min  
²
dIi  
Rext is the series resistor of the voltage source including the supply lines. If this condition is not fulfilled, the converter may not reach  
stable operating conditions. Worst case conditions are at lowest Vi and at highest output power Po.  
Low inductance Lext of the supply lines and an additional capacitor Cext are helpful. Recommended values for Cext are given in table 4,  
which should allow for stable operation up to an input inductance of 2 mH. Ci is specified in table 4.  
ꢁM001c  
Table 4: Ci and recommended values for Cext  
Converter  
Lext  
Rext  
Viꢀ  
Vi–  
Voꢀ  
Vo–  
Model  
BQ  
Ci  
Recomm. Cext  
≥ 680 μF  
≥ 470 μF  
≥ 470 μF  
≥ 470 μF  
≥ 150 μF  
≥ 68 μF  
Voltage  
40 V  
Ri  
Ci  
220 μF  
110 μF  
50 μF  
50 μF  
22 μF  
11 μF  
GQ  
63 V  
CQ  
100 V  
100 V  
125 V  
200 V  
48Q  
DQ  
Fig. 8  
EQ  
Input configuration  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 8 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Electrical Output Data  
General conditions:  
- TA = 25 °C, unless TC is specified.  
- Sense lines connected directly at the connector, inhibit (28) connected to Vi(32).  
- R input not connected; with option P, Vo set to Vo nom at Vi nom  
.
Table 5a: Output data for single-output models and double-output models with both outputs in parallel configuration  
Model  
BQ – GQ1101  
3.3 V  
48Q / BQ – GQ1001  
5.1 V  
48Q / BQ – GQ2320  
12 V  
Unit  
Output  
min  
typ  
max  
min  
typ  
max  
min  
typ  
max  
Characteristics  
Conditions  
3.28  
3.24  
3.32  
3.35  
5.07  
5.02  
5.13  
5.18  
11.94  
12.06  
12.18  
Vo1  
Vow  
Setting voltage of 1st output  
Vi nom, Io nom  
11.82  
Worst case output voltage  
Vi min V  
i max  
V
A
TC min – TC max  
,
Overvoltage limitation  
of second control loop  
4.5  
4.9  
5.9  
6.4  
13.5  
0
14.3  
Vo P  
Io  
Io = 0 – Io max  
Output current 2  
16/203  
8.0/103  
0.05  
25  
0
Vi min V  
i max  
20  
16  
8.0  
Io nom Nominal output current  
Io L  
Output current limit 2  
TC min – TC max  
26  
32.5  
25  
8.4/10.53  
10.4/12.53  
16.8/213  
20.8/263  
20  
15  
25  
10  
20  
10  
20  
20  
40  
Switch. frequency  
Total incl. spikes  
Vi nom, Io nom  
Output  
noise  
4
vo  
mVpp  
W
50  
50  
BW = 20 MHz  
Vi min V  
i max  
82  
82/1023  
96/1203  
Po max Output power1  
TC min – TC max  
4
Voltage deviation  
Recovery time  
±300  
±250  
±200  
vo d  
Dynamic  
load  
regulation  
mV  
V
i nom  
4, 5  
Io nom ½ Io nom  
800  
800  
1500  
td  
μs  
0 V  
Dynamic line regulation  
(output overshoot)  
i max  
0.5  
0.5  
0.8  
vo os  
0 – Io max  
via R-input1  
using opt. P1  
1.1Vi min V  
V
N/A  
N/A  
4.0  
4.6  
5.6  
5.6  
7.2  
13.2  
13.2  
i max  
Output  
voltage trim  
range  
vo tr  
0.1Io nom – Io nom  
10.8  
TC min – TC max  
Io nom,  
TC min – TC max  
±0.02  
±0.02  
±0.02  
α vo  
Temperature coefficient of Vo  
%/K  
1
If the output voltage is increased above Vo nom through R-input control, option P setting, or remote sensing, the output power should be  
reduced accordingly, so that Po max and TC max are not exceeded.  
See Output Power at Reduced Temperature.  
2
3
4
5
First value for 48Q, 2nd value for BQ – GQ  
Measured with a probe according to IEC/EN 61204, annex A  
Recovery time see Dynamic load regulation.  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 9 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Table 5b: Output data for double-output models with both outputs in parallel configuration. General conditions as per table 5a  
Model  
48Q / BQ – GQ2540  
15 V  
48Q / BQ – GQ2660  
24 V  
Unit  
Output  
min  
typ  
max  
min  
typ  
max  
Characteristics  
Conditions  
Setting voltage of 1st output  
Worst case output voltage  
Vi nom, Io nom  
14.93  
15.08  
15.23  
23.88  
23.64  
24.12  
24.36  
Vo1  
14.78  
Vow  
Vo P  
Io  
Vi min V  
i max  
V
A
TC min – TC max  
,
Overvoltage limitation  
of second control loop  
17  
0
18  
27.5  
0
29  
Io = 0 – Io max  
Output current 2  
6.6/8.03  
4.4/5.53  
Vi min V  
i max  
6.6  
4.4  
Io nom Nominal output current  
Io L  
Output current limit 2  
TC min – TC max  
4.6/5.83  
6.2/8.03  
6.9/8.43  
8.6/10.43  
20  
10  
20  
10  
20  
25  
40  
Switch. frequency  
Total incl. spikes  
Vi nom, Io nom  
Output  
noise  
4
vo  
mVpp  
W
40  
BW = 20 MHz  
V
i min V  
i max  
99/1203  
106/1323  
Po max Output power1  
TC min – TC max  
4
Voltage deviation  
Recovery time  
±200  
±600  
vo d  
Dynamic  
load  
regulation  
mV  
V
i nom  
4, 5  
Io nom ½ Io nom  
1500  
800  
td  
μs  
0 V  
Dynamic line regulation  
(output overshoot)  
i max  
0.8  
1.2  
vo os  
0 – Io max  
1.1Vi min V  
V
14.46  
21.6  
26.4  
26.4  
i max  
Output  
voltage trim  
range  
9.0  
16.5  
16.5  
via R-input  
vo tr  
0.1Io nom – Io nom  
using opt. P1  
13.5  
TC min – TC max  
Io nom,  
TC min – TC max  
±0.02  
±0.02  
α vo  
Temperature coefficient of Vo  
%/K  
1
If the output voltages are increased above Vo nom through R-input control, option P setting or remote sensing, the output power should be  
reduced accordingly so that Po max and TC max are not exceeded.  
See Output Power at Reduced Temperature.  
2
3
4
5
6
First value for 48Q, 2nd value for BQ – GQ  
Measured with a probe according to IEC/EN 61204, annex A  
Recovery time until Vo remains within ±1% of Vo, see Dynamic load regulation.  
For DQ2660 and EQ2660: 16.8 V  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 10 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Table 6a: Output data for double-output models with output 1 and output 2 in symmetrical or independent configuration.  
General conditions as per table 5a.  
Model  
48Q /BQ – GQ2320  
12 V / 12 V  
48Q /BQ – GQ2540  
15 V / 15 V  
Unit  
Output  
Output 1  
Output 2  
Output 1  
Output 2  
Characteristics  
Conditions  
min  
typ  
max  
min  
typ  
max  
min  
typ  
max  
min  
typ  
max  
Output setting voltage1  
Vi nom, Io nom  
11.94  
12.06 11.88  
12.12 14.93  
15.08 14.85  
15.15  
Vo  
see Output  
Voltage Regulation  
see Output  
Voltage Regulation  
11.82  
12.18  
14.78  
15.23  
Vow  
Worst case output voltage  
Vi min V  
i max  
V
A
TC min – TC max  
,
Overvoltage limitation  
of second control loop  
N/A  
4.0  
13.5  
0.8  
15  
N/A  
3.3  
17  
0.6  
19  
Vo P  
Io  
Io = 0 – Io max  
Output current 2  
0.8  
7.2/9.23  
7.2/9.23  
0.6  
6.0/7.43  
6.0/7.43  
Vi min V  
i max  
4.0  
3.3  
Io nom Nominal output current  
Io L  
Output current limit 2  
TC min – TC max  
8.4/10.53  
10.4/133 6.9/8.43  
8.6/10.43  
16  
8
16  
40  
8
16  
40  
8
16  
40  
8
Switch. frequency  
Total incl. spikes  
Vi nom, Io nom  
Output  
noise  
4
vo  
mVpp  
W
16  
16  
16  
16  
40  
BW = 20 MHz  
Vi min V  
i max  
96 / 1203  
99 / 1203  
Po max Output power total1  
TC min – TC max  
4
Voltage deviation  
±200  
±300  
±200  
±300  
vo d  
V
mV  
Dynamic  
load  
regulation  
i nom  
Io nom ½ Io nom  
Io 2 = ½ Io nom  
4, 5  
Recovery time  
1500  
1500  
td  
μs  
1.1Vi min V  
i max  
7.2  
13.2  
13.2  
9.0  
16.5  
16.5  
Output  
voltage trim  
range  
via R-input  
see Output  
Voltage Regulation  
see Output  
Voltage Regulation  
vo tr  
V
0.1Io nom – Io nom  
10.8  
13.5  
using opt. P  
TC min – TC max  
Io nom,  
TC min – TC max  
±0.02  
±0.02  
±0.02  
±0.02  
α vo  
Temperature coefficient of Vo  
%/K  
1
If the output voltages are increased above Vo nom through R-input control, option P setting, or remote sensing, the output power should be  
reduced accordingly so that Po max and TC max are not exceeded.  
See Output Power at Reduced Temperature.  
2
3
4
5
6
First value for 48Q, 2nd value for BQ – GQ  
Measured with a probe according to IEC/EN 61204, annex A  
Recovery time until Vo remains within ±1% of Vo, see Dynamic load regulation.  
Io nom = Io1 + Io2  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 11 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Table 6b: Output data for double-output models with output 1 and output 2 in symmetrical or independent configuration.  
General conditions as per table 5a  
Model  
48Q2660  
BQ – GQ2660  
24 V / 24 V  
Unit  
Output  
24 V / 24 V  
Output 1  
Output 2  
Output 1  
Output 2  
Characteristics  
Conditions  
min  
typ  
max  
min  
typ  
max  
min  
typ  
max  
min  
typ  
max  
Output setting voltage1  
Vi nom, Io nom  
23.88  
24.12 23.76  
24.24 23.88  
24.12 23.76  
24.24  
Vo  
see Output  
Voltage Regulation  
see Output  
Voltage Regulation  
23.64  
24.36  
23.64  
24.36  
Vow  
Worst case output voltage  
Vi min V  
i max  
V
A
TC min – TC max  
,
Overvoltage limitation  
of second control loop  
N/A  
2.2  
27.5  
0.4  
30  
N/A  
2.2  
27.5  
0.4  
30  
Vo P  
Io  
Io = 0 – Io max  
Output current 2  
0.4  
4.6  
4.0  
4.0  
0.4  
5.8  
5.1  
5.1  
Vi min V  
i max  
2.2  
2.2  
Io nom Nominal output current  
Io L  
Output current limit 2  
TC min – TC max  
6.2  
25  
40  
8.0  
25  
40  
10  
20  
25  
40  
10  
20  
10  
20  
25  
40  
10  
20  
Switch. frequency  
Total incl. spikes  
Vi nom, Io nom  
Output  
noise  
4
vo  
mVpp  
W
BW = 20 MHz  
Vi min V  
i max  
Po max Output power total1  
106  
132  
TC min – TC max  
4
Voltage deviation  
±400  
±500  
±400  
±500  
vo d  
V
mV  
Dynamic  
load  
regulation  
i nom  
Io nom ½ Io nom  
Io 2 = ½ Io nom  
4, 5  
Recovery time  
400  
400  
td  
μs  
1.1Vi min V  
14.4  
26.4  
14.43  
21.6  
26.4  
26.4  
i max  
Output  
voltage trim  
range  
via R-input  
see Output  
Voltage Regulation  
see Output  
Voltage Regulation  
vo tr  
V
0.1Io nom – Io nom  
N/A  
using opt. P  
TC min – TC max  
Io nom,  
TC min – TC max  
±0.02  
±0.02  
±0.02  
±0.02  
α vo  
Temperature coefficient of Vo  
%/K  
1
If the output voltages are increased above Vo nom through R-input control, option P setting or remote sensing, the output power should be  
reduced accordingly so that Po max and TC max are not exceeded.  
See: Output Power at Reduced Temperature  
For DQ2660 and EQ2660: 16.8 V  
Measured with a probe according to IEC/EN 61204, annex A  
2
3
4
5
Recovery time until Vo remains within ±1% of Vo, see Dynamic load regulation  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 12 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Parallel and Series Connection  
Single- or double-output models with equal output voltage can be connected in parallel without any precaution, by interconnecting  
the T-pins for equal current sharing; see fig. 9a.  
Double-output models with their outputs connected in parallel behave exactly like single-output models and are fully regulated.  
There is no inconvenience or restriction using the R-input with sense lines.  
Single-output and/or double-output models can be connected in series. For double-output models with both outputs connected in  
series, consider that the effect via sense lines, R-input or option P is doubled. See fig. 9b.  
Parallel configuration of double-output models with both outputs connected in series is shown in fig. 9c. It is essential that the  
Vo1– pins of all paralleled converters are connected together, as the auxiliary signals are referenced to Vo1– or to S–. The effect  
via sense lines, R-input or option P is doubled.  
050ꢁ1b  
050ꢁ2a  
T
Rp  
DR  
Rp  
Voꢀ/Vo1ꢀ  
Out OKꢀ Vo2ꢀ  
Out OKꢀ  
Out OK–  
Sꢀ  
S–  
Vo2–  
Vo1ꢀ  
Out OK –  
i
i
Vo–/Vo1–  
Voꢀ/Vo2ꢀ  
Vo–/Vo2–  
Viꢀ  
Vi–  
Sꢀ  
S–  
Viꢀ  
Vi–  
Vo1–  
T
DR  
Voꢀ/Vo1ꢀ  
Out OKꢀ Vo2ꢀ  
Sꢀ  
S–  
Out OKꢀ  
Out OK–  
Vo2–  
Vo1ꢀ  
Out OK –  
i
Vo–/Vo1–  
Voꢀ/Vo2ꢀ  
Vo–/Vo2–  
i
Viꢀ  
Vi–  
Sꢀ  
S–  
Viꢀ  
Vi–  
Vo1–  
i
i
Fig. 9a  
Fig. 9b  
Parallel connection of single- and double-output models.  
Series connection of double-output models.  
06114a  
T
Vo2ꢀ  
Vo2–  
Vo1ꢀ  
Double  
output  
Rp  
Out OKꢀ  
Out OK –  
Sꢀ  
S–  
i
Notes:  
Viꢀ  
Vi–  
If the second output of double-output models is not used,  
connect it in parallel to the main output to maintain good  
regulation.  
Vo1–  
R
Parallel connection of several double-output models should  
always include main and second outputs to produce good  
regulation.  
Double  
output  
T
Vo2ꢀ  
Vo2–  
Vo1ꢀ  
Series connection of second outputs without involving their  
main outputs should be avoided as regulation may be poor.  
Out OKꢀ  
The maximum output current is limited by the output with the  
lowest current limit, if several outputs are connected in series.  
Out OK –  
Sꢀ  
S–  
i
Rated output voltages above 48 V (SELV = Safety Extra Low  
Voltage) need additional measures in order to comply with  
international safety requirements.  
Viꢀ  
Vi–  
Vo1–  
R
i
Fig. 9c  
Parallel connection of double-output models with series-connected outputs.  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 13 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Redundant Configuration  
Fig. 10a shows a circuit with ORing diodes DR in the positive output lines, forming a redundant configuration. For accurate output  
voltage regulation, the sense lines are connected after the ORing diodes. The T pins should be connected together to produce  
reasonable current sharing between the parallel-connected converters.  
If one of the converters fails, the remaining converters can deliver the whole output power.  
Note: The current-share logic can only increase the output voltage marginally and remains functional even in the case of a failing converter.  
Fig. 10b shows a quite similar circuit with ORing diodes DR, but with different output loads. To compensate for the voltage drop of the  
ORing diodes (if necessary), an auxiliary circuit is added to each power supply consisting of a small diode DS and a small resistor RS.  
We recommend a current of approximately 10 mA through DS and RS. Only Load 0 benefits from a secured supply voltage.  
The current sharing may be improved by interconnecting the T pins of the converters. This circuit is a bit less accurate, but more  
flexible and less sensitive.  
Caution: Do not connect the sense lines after the ORing diodes, but directly with the respective outputs. If for some reason one of the  
converters switches off and the ORing diode is blocking, a reverse voltage can appear between the sense pin and the respective output pin  
and damage the converter.  
050ꢁ1b  
060ꢁ7b  
T
T
DR  
DR  
Rp  
Rp  
Voꢀ/Vo1ꢀ  
Voꢀ/Vo1ꢀ  
DS  
RS  
Out OKꢀ  
Out OK–  
Out OKꢀ  
Out OK–  
Sꢀ  
S–  
Sꢀ  
S–  
i
Vo–/Vo1–  
Voꢀ/Vo2ꢀ  
Vo–/Vo2–  
i
Vo–/Vo1–  
Voꢀ/Vo2ꢀ  
Vo–/Vo2–  
Viꢀ  
Vi–  
Viꢀ  
Vi–  
T
T
DR  
DR  
Voꢀ/Vo1ꢀ  
Voꢀ/Vo1ꢀ  
DS  
Sꢀ  
S–  
Sꢀ  
S–  
Out OKꢀ  
Out OK–  
Out OKꢀ  
Out OK–  
RS  
Vo–/Vo1–  
Voꢀ/Vo2ꢀ  
Vo–/Vo2–  
Vo–/Vo1–  
Voꢀ/Vo2ꢀ  
Vo–/Vo2–  
i
i
Viꢀ  
Vi–  
Viꢀ  
Vi–  
i
i
Fig. 10a  
Fig. 10b  
Simple redundant configuration of double-output models  
with parallel-connected outputs.  
Redundant configuration of double-output models with par-  
allel-connected outputs.  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 14 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Output Voltage Regulation  
The dynamic load regulation is shown in figure 11.  
The static load regulation measured at the sense pins is negligible. Correct connection of the sense lines almost eliminates any  
load regulation; see Sense Lines.  
In a symmetrical configuration the output 1 with open R input is regulated to Vo1 nom, regardless of the output currents. If the load  
on output 2 is too small (<10% of Io nom), its voltage will rise and may activate the overvoltage protection, which will then reduce  
the voltage on both outputs.  
Vo2 depends upon the load distribution: If each output is loaded with at least 10% of Io nom, the deviation of Vo2 remains within ±5%  
of Vo nom. The following figures explain the regulation with different load distributions up to the current limit. If Io1 = Io2 or the two  
outputs are connected in series, the deviation of Vo2 remains within ±1% of the value ofVo nom, provided that the load is at least Iomin  
.
Note: If output 2 is not used, we recommend to connect it in parallel to Vo1. This results in improved efficiency and stability.  
V
o2 [V]  
Vo  
05111b  
Vod  
Vo 1ꢁ  
Vod  
Vo 1ꢁ  
Io1 = 7.2 A  
Io1 = 5.6 A  
I
o1 = 4.0 A  
Vo1 ꢀ 0.5 V  
Io1 = 2.4 A  
td  
td  
I
I
o1 = 0.8 A  
o1 = 0.4 A  
t
Vo1  
Io/Io nom  
1
Vo1 – 0.5 V  
0.5  
10 µs  
10 µs  
I
o2 [A]  
0
t
0
2
4
6
8
10  
05102c  
Fig. 11  
Fig. 12  
Deviation of Vo versus dynamic load change  
Double-output models with 12 V: Voltage deviation of Vo2  
versus Io2 for different currents on output 1  
Vo2 max = 28 V  
Vo2 max = 18 V  
Vo2 [V]  
V
o2 [V]  
05113a  
05112a  
Io1 = 4.0 A  
Io1 = 6.0 A  
o1 = 4.6 A  
Io1 = 3.3 A  
o1 = 2.0 A  
Io1 = 3.1 A  
Io1 = 2.2 A  
Io1 = 1.3 A  
Io1 = 0.44 A  
I
Vo1 ꢀ 1.0 V  
Vo1 ꢀ 0.5 V  
I
Io1 = 0.66 A  
Vo1  
Vo1  
Vo1 – 1.0 V  
Vo1 – 0.5 V  
Io2 [A]  
Io2 [A]  
5
0
1
2
3
4
6
0
2
4
6
8
Fig. 13  
Fig. 14  
Double-output models with 15 V: Voltage deviation of Vo2  
Double-output models with 24 V: Voltage deviation of Vo2  
versus Io2 for different currents on output 1  
versus Io2 for different currents on output 1  
Output Overvoltage Protection  
Output voltage overshoot may occur, if the converter is either hot plugged-in or disconnected, the input voltage is switched on or  
off, the converter is switched with an inhibit signal, or after a reset of a short circuit and power failure. Output overvoltage can also  
result due to incorrectly wired sense lines.  
A fully independent output voltage monitor (second control loop) limits the voltage Vo or Vo2 to approximately 1.25 • Vo nom (in double-  
output models, the 2nd output is monitored). This circuitry further protects the load in the unlikely event of a malfunction of the main  
control circuit.  
There is no specific built-in protection against externally applied overvoltage.  
Note: If output 2 is not loaded, the 2nd control loop may reduce Vo1 under boundary conditions.  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 15 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Output Current Protection  
All outputs are fully protected against continuous open-circuit condition or continuous short-circuit by an electronic current limitation  
located on the primary side.  
Single-output models and series- or parallel-connected double-output models have a quasi rectangular constant current limitation  
characteristic.  
In double-output models, only the total current is limited, allowing free choice of load distribution between the two outputs, up to  
Io1 + Io2 Io max. However, a small current should remain on both outputs to guarantee good voltage regulation. In case of overload  
(Io1 + Io2 > Io max) both output voltages are reduced simultaneously.  
Current distribution in overload is dependent upon the type of overload. A short-circuit in one output will cause the full current flow  
into that output, whereas a resistive overload results in more even distribution and in a reduced output voltage.  
V /V  
o
Vo/Vo nom  
o nom  
Io nom  
Io L  
I
I
I
o max o L  
o nom  
05104b  
05114c  
1.0  
0.ꢀ5  
1.0  
0.8  
0.6  
0.5  
0.4  
0.2  
Io/Io nom  
0
0
I
0
o
0.2  
0.4  
0.6  
0.8  
1.0  
1.2  
1.4  
Fig. 15a  
Fig. 15b  
BQ – GQ models: Current limitation of single- or double-output  
48Q models: Current limitation of single- or double-output  
models with series-connected outputs (no opt. B or B1)  
models with series-connected outputs (no opt. B or B1)  
Efficiency  
η [ꢁ]  
η [ꢁ]  
ꢂM082  
ꢂM083  
ꢀ0  
ꢀ0  
Vi nom  
Vi nom  
Vi min  
Vi min  
85  
85  
Vi max  
Vi max  
80  
80  
Io [A]  
Io [A]  
75  
75  
3
5
1
2
3
5
1
2
4
4
Fig. 16a  
Fig. 16b  
Efficiency versus input voltage and current per output  
(BQ2320)  
Efficiency versus input voltage and current per output  
(EQ2320)  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 16 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Hold-up Time  
The Q Series converters provide virtually no hold-up time. If hold-up time or interruption time is required, use external output  
capacitors or decoupling diodes together with input capacitors of adequate size.  
Formula for additional external input capacitor:  
2 • Po th • 100  
Ci ext = –––––––––––––––  
2
η • (Vti 2 Vi min  
)
where as:  
Ci ext = external input capacitance [mF]  
P
= output power [W]  
= efficiency [%]  
= hold-up time [ms]  
ηo  
th  
Vi min = minimum input voltage [V]  
Vti = threshold level [V]  
Thermal Considerations and Protection  
If a converter is located upright in quasi-stationary air (convection cooling) at the indicated maximum ambient temperature TAmax (see  
table Temperature specifications), and is operated at its nominal input voltage and output power, the temperature TC measured at the  
Measuring point of case temperature (see Mechanical Data) will approach TC max after the warm-up phase. However, the relationship  
between TA and TC depends heavily on the operating conditions and the integration into a system. The thermal conditions are  
influenced by input voltage, output current, airflow, and temperature of surrounding components and surfaces. TA max is therefore,  
contrary to TC max, an indicative value only.  
Caution: The installer must ensure that under all operating conditions TC remains within the limits stated in the table Temperature specifications.  
Note: Sufficient forced cooling or an additional heat sink improves the reliability or allows TA to be higher than TA max, as long as TC max is not  
exceeded. In rack systems without proper thermal management, the converters must not be packed too densely! In such cases the use of a  
5 or 6 TE front panel is recommended.  
A temperature sensor generates an internal inhibit signal, which disables the outputs, if the case temperature exceeds TC max. The  
outputs are automatically re-enabled when the temperature drops below this limit. This feature is not fitted to 48Q models.  
Operating BQ – GQ models with output current beyond Io nom requires a reduction of the ambient temperature TA to 50 °C or forced  
cooling. When TCmax is exceeded, the converter runs into its thermal protection and switches off; see fig. 17a.  
Note: According to EN 50155, Class OT4, the converters BQ – GQ can be operated with Po nom continously at TA = 70 °C, and then for 10 min  
at TA = 85 °C without shutdown.  
Fig. 17b shows the operation of 48Q models beyond TA = 50 °C with forced cooling.  
Po  
forced  
cooling  
Po  
Po nom  
05116b  
Po max  
Po nom  
0.75 P  
05110b  
forced  
cooling  
convection  
cooling  
o nom  
TC max  
convection  
cooling  
TC max  
0.4 Po nom  
TA  
–10  
30  
40  
50  
60  
70 80 °C  
TA  
ꢀ0 100 °C  
TA min 50  
60  
70  
80  
Fig. 17a  
Output power derating versus TA for BQ – GQ models  
Fig. 17b  
Output power derating versus TA for 48Q models  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 17 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Auxiliary Functions  
Inhibit for Remote On/Off  
Note: If this function is not used, the inhibit pin 28 must be connected with pin 32 to enable the output(s). A non-connected pin 28 will be  
interpreted by the internal logic as an active inhibit signal and the output(s) will remain disabled (fail safe function).  
An inhibit input enables (logic low, pull down) or disables (logic high, pull up) the output, if a logic signal, e.g. TTL, CMOS is  
applied. In systems consisting of several converters, this feature may be used, for example, to control the activation sequence of  
the converters by means of logic signals, or to allow the power source for a proper start-up, before full load is applied.  
Table 7: Inhibit characteristics  
Characteristics  
Conditions  
min  
-50  
2.4  
typ  
max  
0.8  
50  
Unit  
Vo = on  
Vo = off  
Vi min Vi max  
Vinh Inhibit voltage  
V
TC min – TC max  
Vinh = -50 V  
Vinh = 0 V  
-500  
-40  
Iinh  
Inhibit current  
µA  
Vinh = 50 V  
+500  
The output response, when enabling and disabling the output by the inhibit input, is shown in figure 19.  
Vo/Vo nom  
0615ꢀb  
tr  
tf  
060ꢁ1a  
1.01  
0.ꢀꢀ  
Iinh  
12  
4
28  
30  
Sꢀ  
Voꢀ  
Voꢀ  
i
Io  
Vinh  
0.1  
0
t
t
t
Ii  
6
Viꢀ  
Vi–  
ton  
Vo  
Vi  
Vi  
8
Vi min  
Vo–  
0
32  
26  
Vo– 10  
V
inh [V]  
14  
S–  
2.4  
0.8  
Fig. 18  
Definition of input and output parameters  
Fig. 19  
Output response as a function of Vi (on/off switching) or  
inhibit control  
Table 8: Inhibit response times (typ. values, outputs with ohmic load, R-input left open-circuit)  
Characteristics  
Conditions  
BQ  
48Q  
CQ  
GQ  
DQ*  
EQ*  
Unit  
Vi nom, RL = Vo nom / Io nom  
Vinh = 2.4 → 0.8 V  
Output voltage rise time  
(indicative values)  
tr  
1.5  
1.3  
1.3  
1.5  
1.5  
1.6  
V
3.3 V  
5 V  
0.5  
0.8  
1.3  
3
0.5  
0.6  
1.2  
3
0.5  
0.6  
1.3  
3
0.5  
0.8  
1.5  
3
0.5  
0.7  
1.1  
3
0.5  
0.7  
1.5  
3
tr  
Vi nom, RL = Vo nom / Io nom  
Vinh = 0.8 → 2.4 V  
Output voltage fall time  
(indicative values)  
µA  
Vi min  
12 / 15 V  
24 V  
* Models with version V104 or higher  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 18 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Current Sharing  
The current sharing facility should be used when several converters are operated in parallel or redundant connection. This feature  
avoids that some converters are driven into current limitation and thus produce excessive losses. As a result, the stress of the  
converters is reduced, and the system reliability is further improved.  
Simple interconnection of the T pins causes the converters to share the output current. The current tolerance of each converter is  
approx. ±20% of the sum of its nominal output currents Io1 nom + Io2 nom  
.
In n+1 redundant systems, a failure of a single converter will not lead to a system failure, if the outputs are decoupled by diodes;  
see fig. 10.  
Note: T-function only increases the output voltage, until the currents are evenly shared. If in a redundant system, one converter fails, the  
remaining converters keep sharing their currents evenly.  
Since the T pins are referenced to the pins S, the S– pins of all converters must have the same electrical potential.  
Double-output converters with both outputs connected in series can also be paralleled with current sharing, if pins Vo1– of all  
converters are connected together, see fig. 9c.  
If the output voltages are programmed to a voltage other than Vo nom by means of the R pin or option P, the outputs should be  
adjusted individually within a tolerance of ±1%.  
Important: For applications using the hot-swap capabilities, dynamic output voltage changes during plug-in/plug-out must be considered.  
Programmable Output Voltage (R-Function)  
This feature is not available on models with 3.3 V output or with option P.  
Note: Models with 3.3 V output or with option P: The R-input must be left open-circuit.  
The converters offer a programmable output voltage. The adjust is performed either by an external control voltage Vext or an  
external resistor R1 or R2, connected to the R-input. Trimming is limited to the values given in the table below (see also Electrical  
Output Data). With open R-input, the output voltage is set to Vo nom  
.
With double-output models, both outputs are affected by the R-input settings.  
If output voltages are set higher than Vo nom, the output currents should be reduced accordingly, so that the maximum specified  
output power is not exceeded.  
a) Adjustment by means of an external control voltage Vext between R (pin 16) and S– (pin 14); see fig. 20.  
Vo  
Vext  
–––––  
Vo nom  
–––––  
2.5 V  
Vext 2.5 V •  
Vo Vo nom •  
Caution: To prevent damage, Vext should not exceed 20 V, nor be negative.  
b) Adjustment by means of an external resistor:  
The resistor can either be connected:  
• between R (pin 16) and S(pin 14) to set Vo < Vo nom, or  
between R (pin 16) and S+ (pin 12) to set Vo > Vo nom  
.
Vext  
060ꢁ4b  
060ꢁ3b  
Double-  
output  
model  
R
R
Single-output  
model  
16  
4
16  
4
R2  
Vo1ꢀ  
Voꢀ  
Voꢀ  
R1  
6
Sꢀ  
S–  
12  
14  
8
Load 1  
Load 2  
Sꢀ 12  
S– 14  
i
i
Load  
Viꢀ  
Vi–  
Vo1–  
Vo2ꢀ  
Vo2–  
Viꢀ  
Vi–  
Vo–  
8
6
Vo–  
10  
10  
Fig. 20  
Output adjust using an external control voltage Vext.  
Fig. 21  
Output adjust using a resistor R1 (to lower Vo) or  
R2 (to increase Vo).  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 19 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Table 9a: R1 for Vo < Vo nom; approximate values (Vi nom, Io nom, series E 96 resistors); R2 = not fitted  
Vo nom = 5.1 V  
Vo nom = 12 V  
Vo [V]1  
Vo nom = 15 V  
Vo [V]1  
Vo nom = 24 V  
Vo [V]1  
Vo [V]  
R 1 [kΩ]  
R 1 [kΩ]  
R 1 [kΩ]  
R 1 [kΩ]  
4.0  
4.1  
4.2  
4.3  
4.4  
4.5  
4.6  
4.7  
4.8  
4.9  
5.0  
14.7  
16.5  
18.2  
21.5  
25.5  
30.1  
37.4  
47.5  
64.9  
97.6  
200  
152  
162  
172  
182  
19  
20  
20.5  
21  
21.5  
22  
22.5  
23  
30.02  
32.02  
34.02  
36.02  
38.0  
40.0  
41.0  
42.0  
43.0  
44.0  
45.0  
46.0  
47.0  
6.652  
8.062  
9.762  
12.1  
15.4  
20.0  
23.7  
28.0  
34.8  
44.2  
60.4  
90.9  
190  
9
9.5  
10  
10.5  
11  
11.5  
12  
12.5  
13  
13.5  
14  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
6.04  
6.98  
8.06  
9.31  
11  
13.3  
16.2  
20  
26.1  
36.5  
56.2  
115  
7
7.5  
8
8.5  
9
9.5  
10  
10.5  
11  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
5.62  
6.65  
8.06  
9.76  
12.1  
15.4  
20  
28  
44.2  
93.1  
11.5  
14.5  
23.5  
Table 9b: R2 for Vo > Vo nom; approximate values (Vi nom, Io nom, series E 96 resistors); R1 = not fitted  
Vo nom = 5.1 V  
Vo nom = 12 V  
Vo [V]1  
Vo nom = 15 V  
Vo [V]1  
Vo nom = 24 V  
Vo [V]  
R 2 [kΩ]  
R 2 [kΩ]  
R 2 [kΩ]  
Vo [V]1  
R 2 [kΩ]  
5.2  
5.3  
5.4  
5.5  
5.6  
215  
110  
75  
57.6  
46.4  
12.2  
12.4  
12.6  
12.8  
13.0  
13.2  
24.4  
24.8  
25.2  
25.6  
26.0  
26.4  
931  
475  
316  
243  
196  
169  
15.3  
15.5  
15.7  
16.0  
16.2  
16.5  
30.6  
31  
31.4  
32  
32.4  
33  
1020  
619  
453  
316  
267  
221  
24.5  
25  
25.5  
26  
49  
50  
51  
52  
52.8  
1690  
866  
590  
442  
374  
26.4  
1
2
First column: single or double output models with separated/paralleled outputs, second column: outputs in series connection.  
Not possible for DQ2660 and EQ2660.  
Output Good Signal (Out-OK)  
The isolated Out-OK output gives a status indication of the converter and the output voltage. It can be used for control functions  
such as data protection, central system monitoring or as a part of a self-testing system. It can be connected to get a centralized  
fault detection or may be used for other system-specific applications at the primary or the secondary side of the converter.  
Connecting the Out-OK as per fig. 22, VOK <1.0 V indicates that the Vo or Vo1 of the converter is within the range Vt1low Vt1high. Vt1 low  
corresponds to 0.95 - 0.98 Vo1 nom, Vt1high to 1.02 – 1.05 Vo1nom  
.
Note: Using the R-input or the option P, the monitor level is tracking the programmed output voltage.  
In an error condition, if the output voltage is out of range due to overload or an external overvoltage, VOK willapproach Vp.  
The output is formed by an NPN transistor. The emitter (Out OK–) can be connected to primary Vi– or secondary Vo1– to get  
an open-collector output. In a configuration of several Q Series converters, the Out OK pins can be series-connected in order to  
get a system level signal (as shown in fig. 9). If one of the converters fails, the series-connected output rises to high impedance.  
Vp  
Dimensioning of resistor value Rp ––––––  
0.5 mA  
Caution: Out-OK is protected by an internal series resistor and a Zener diode. To prevent damage, the applied current IOK  
should be limited to ±10 mA.  
Table 10: Out-OK data  
Vp  
060ꢁ6a  
Rp  
Characteristics  
Conditions  
min typ max Unit  
IOK  
1 k  
22  
24  
Out OKꢀ  
Out OK–  
VOK Out-OK voltage Output OK, IOK< 0.5 mA  
0.8  
1.0  
25  
V
Output  
control  
circuit  
20 V  
VOK  
IOK  
Out-OK current Output fail, VOK ≤ 15 V  
µA  
Fig. 22  
Out OK function  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 20 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Sense Lines  
This feature allows for compensation of voltage drops at the main output across connector contacts and load lines. If the sense  
lines are connected at the load rather than directly at the connector, the user must ensure that the differential voltages (measured  
on the connector) VS+ (between Vo+ and S+) and VS(between Vo– and S–) do not exceed the values in the table 11.  
Table 11:Voltage compensation by sense lines  
Nominal output  
voltage  
VS+  
VS_  
Sum of  
VS+ + ∆VS_  
Unit  
3.3 V, 5.1 V  
≤ 0.5  
≤ 0.25  
≤ 0.5  
12 V, 15 V  
24 V  
≤ 1.0  
≤ 1.0  
≤ 0.5  
≤ 1.0  
≤ 1.0  
≤ 2.0  
V
Applying generously dimensioned cross-section load leads help avoiding troublesome voltage drops. To minimize noise pick-up,  
wire the sense lines parallel or twisted. For unsymmetrical loads, we recommend connecting the sense lines directly at the female  
connector.  
To ensure correct operation, both sense lines must be connected to their respective power output. With double-output models, the  
sense lines must be connected to output 1 only. Caution should be exercised, if outputs are series-connected, as the compensated  
voltage is effectively doubled. Because the effective output voltage and output power are increased by the sense lines, the  
minimum input voltage rises proportionally to the compensated output voltage.  
Caution: Sense lines should always be connected. Incorrectly connected sense lines may cause an overvoltage at the output, which could  
damage the output load and activate the second control loop. The sense lines can handle only small currents.  
Note: Sense line connection in a redundant configuration is shown in fig. 10.  
Test Sockets and LEDs  
Test jacks (for pin diameter 2 mm) are located at the front of the converter and allow monitoring the main output voltage at the  
sense line terminals. The test sockets are protected by internal series resistors. Double-output models show the sense line voltage  
of output 1 at the test jacks. 48Q models have no test sockets.  
48Q models exhibit a green LED In-OK to monitor the input voltage. BQ – GQ models have an additional LED Out-OK, which is  
activated simultaneously to the Out-OK signal.  
Table 12: Display status of LEDs  
LED In OK  
green  
LED Out OK Operating condition  
green  
x
normal operation  
green  
incorrect sense line connection  
green  
off  
overtemperature  
overload  
output overvoltage  
output undervoltage  
off  
off  
green  
not possible  
off  
no input voltage  
input voltage too low  
input voltage too high  
inhibit input open/high  
x = dependent on actual operating condition  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 21 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Electromagnetic Compatibility (EMC)  
Ametal oxide VDR together with an input fuse and a symmetrical input filter form an effective protection against high input transient  
voltages, which typically occur in most installations, especially in battery-driven mobile applications. The Q Series has been  
successfully tested to the following specifications:  
Electromagnetic Immunity  
Table 13: Electromagnetic immunity (type tests)  
Phenomenon  
Standard  
Level Coupling mode 1  
Value  
applied  
Waveform  
Source Test procedure  
imped.  
In  
Perf.  
oper. crit.2  
Supply related  
surge  
RIA 123  
1.5 • VBat  
1.4 • VBat  
B
+i/–i  
0.1/1/0.1 s  
0.2 Ω  
5 Ω  
1 positive surge  
yes  
yes  
A
A
EN 50155:2017  
13.4.3  
Direct transients RIA 12  
D
G
H
L
±1800 Vp  
±8400 Vp  
1800 Vp  
8400 Vp  
5/50 μs  
5 pos. & 5 neg.  
impulses  
–i/c, +i/–i  
0.05/0.1 μs  
5/50 μs  
Indirect couples  
transients  
100 Ω  
–o/c, +o/–o, –o/–i  
0.05/0.1 μs  
Electrostatic  
discharge  
(to case)  
IEC/EN  
61000-4-2  
contact discharge 8000 Vp  
10 pos. & 10 neg.  
discharges  
330 Ω  
150 pF  
4 4  
x 5  
1/50 ns  
yes  
yes  
A
A
15000 Vp  
air discharge  
Electromagnetic IEC/EN  
field  
antenna  
antenna  
20 V/m  
20 V/m  
10 V/m  
5 V/m  
AM 80% / 1 kHz  
N/A  
N/A  
80 – 1000 MHz  
61000-4-3  
800 – 1000 MHz  
1400 – 2000 MHz  
2000 – 2500 MHz  
5100 – 6000 MHz  
6
AM 80% / 1 kHz  
yes  
A
3 V/m  
7
Electrical fast  
transients / burst 61000-4-4  
IEC/EN  
3 7  
4
direct coupl. (fig. 9) ±2000 Vp  
60 s positive  
60 s negative  
transients per  
coupling mode  
yes  
yes  
A
B
+i/c, –i/c,+i/–i  
burstsof 5/50ns;  
5 kHz over 15 ms;  
burst period: 300 ms  
±4000 Vp  
50 Ω  
capacit. (fig. 10),  
±2000 Vp  
o/c  
3
yes  
yes  
B
A
3
Surges  
IEC/EN  
61000-4-5  
5 pos. & 5 neg.  
surges per  
coupling mode  
+i/c, – i/c  
+i/i  
±2000 Vp  
42 Ω /  
0.5 μF  
3 3  
10  
1.2 / 50 µs  
3
1000 Vp  
FTZ 19 Pfl 1  
3 pos. 5  
repetitions  
+i/i  
150 Vp  
0.1/0.3 ms  
<100 A  
yes  
yes  
yes  
A
A
A
Conducted  
disturbances  
IEC/EN  
61000-4-6  
10 VAC  
3 8  
11  
i, o, signal wires  
-
AM 80% / 1 kHz  
150 Ω 0.15 – 80 MHz  
(140 dBµV)  
Power frequency IEC/EN  
magnetic field  
100 A/m  
60 s in all 3 axes  
61000-4-8  
1
i = input, o = output, c = case.  
A = normal operation, no deviation from specs; B = temporary loss of function or deviation from specs possible  
Measured with an external input cap specified in table 4. Exceeds EN 50121-3-2:2016 table 3.3 and EN 50121-4:2016 table 4.3.  
Exceeds EN 50121-3-2:2016 table 5.3 and EN 50121-4:2016 table 2.1.  
Corresponds to EN 50121-3-2:2016 table 5.1 and exceeds EN 50121-4:2016 table 1.1.  
Corresponds to EN 50121-3-2:2016 table 5.2 and EN 50121-4:2016 table 2.2  
Corresponds to EN 50121-3-2:2016 table 3.2 and EN 50121-4:2016 table 4.2.  
Covers or exceeds EN 50121-3-2:2016 table 3.1 and EN 50121-4:2016 table 4.3 (radio frequency common mode).  
Corresponds to EN 50121-4:2016 table 2.3.  
2
3
4
5
6
7
8
9
10  
Valid for 48Q and CQ only.  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 22 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Electromagnetic Emissions  
All conducted emissions (fig. 23) have been tested according to EN 55011, group 1, class A (similar to EN 55032). These limits  
are much stronger than requested in EN 50121-3-2:2016, table 2.1 and correspond to EN 50121-4:2016, table 1.1. The limits in  
fig. 23 apply to quasipeak values, which are always lower then peak values.  
In addition, the values for average must keep a limit 10 dBµV below the limits in fig. 23 (not shown).  
Radiated emissions have been tested according to EN 55011 group 1, class A . These limits are similar to the requirements of  
EN 50121-3-2:2016 and EN 50121-4:2016 calling up EN 61000-6-4+A1:2011, table 1. The test is executed with horizontal and  
vertical polarization. The worse result is shown in fig. 24.  
PMM 8000 PLUS: Peak, conducted Viꢀ, Clp 2007-06-07, 15:38 h  
PMM 8000 PLUS: Peak, conducted Viꢀ, Clp 2007-06-07, 14:46 h  
dBµV  
80  
dBµV  
80  
CQ2320-7R V104, U  
=48 V, U =12 V I = 8 A, decoupled load  
BQ1001-7R V104, U  
=24 V, U =5.1 V, I  
= 16 A, decoupled load  
i
o
o
i
o
o
ꢁM01ꢂ  
ꢁM020  
EN 55022 B  
EN 55022 B  
60  
40  
20  
0
60  
40  
20  
0
,
0.2  
0.5  
1
2
5
10  
20 MHz  
0.2  
0.5  
1
2
5
10  
20 MHz  
Fig. 23a  
Fig. 23b  
Conducted peak disturbances at the input: BQ1001-7R V104,  
Conducted peak disturbances at the input: CQ2320-7R V104,  
Vi nom, Io nom, decoupled load lines  
Vi nom, Io nom, outputs parallel connected, decoupled load lines  
PMM 8000 PLUS: Peak, conducted Viꢀ, Clp 2007-06-05, 15:15  
h
dBµV  
80  
EQ2660-7R V102,  
U
=110 V, U  
=24 V I = 4 A, decoupled load  
i
o
o
ꢁM021  
EN 55011 B  
60  
40  
20  
0
0.2  
0.5  
1
2
5
10  
20 MHz  
Fig. 23c  
Conducted peak disturbances at the input: EQ2660-7R V102,  
Vi nom , Io nom, outputs parallel connected, decoupled load lines  
TꢀV-Divina, ESVS 30:R&S, BBA ꢁ106/UHALP ꢁ107:Schwarzb., QP, 200ꢁ-04-21  
dBµV/m  
TꢁV-Divina, ESVS 30:R&S, BBA ꢂ106/UHALP ꢂ107:Schwarzb., QP, 200ꢂ-04-17  
Testdistance 10 m, BQ2660-7R V104, U  
=24 V, U =24 V I  
= 4.4 A  
i
o
o
dBµV/m  
Testdistance 10 m, EQ2660-7R V104, U  
=110 V, U  
=24 V I  
= 4.4 A  
i
o
o
50  
EN 55011 A  
50  
EN 55011 A  
40  
40  
< 30 dB(µV/m)  
< 30 dB(µV/m)  
30  
20  
30  
20  
10  
0
10  
0
30  
50  
100  
200  
500  
1000 MHz  
30  
50  
100  
200  
500  
1000 MHz  
Fig. 24a  
Fig. 24b  
Radiated disturbances in 10 m distance: BQ2660-7R V104,  
Vi nom, Io nom  
Radiated disturbances in 10 m distance: EQ2660-7R V104,  
Vi nom, Io nom  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 23 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Immunity to Environmental Conditions  
Table 14: Mechanical and climatic stress  
Test method  
Standard  
Test Conditions  
Temperature:  
Status  
Cab Damp heat  
steady state  
IEC/EN 60068-2-78  
MIL-STD-810D section 507.2  
40±2 °C  
Converter  
not operating  
Relative humidity:  
Duration:  
93+2/-3  
%
56 days  
55°C and 25°C  
2
Db  
Damp heat test,  
cyclic  
EN 50155:2017, clause 13.4.7  
IEC/EN 60068-2-30  
Temperature:  
Converter  
not operating  
Cycles (respiration effect)  
Duration:  
2x 24 h  
Be  
Ad  
Ka  
Dry heat test  
steady state  
EN 50155:2017, clause 13.4.5  
ST1, IEC/EN 60068-2-2  
Temperature:  
70 °C (85 °C)  
6 h (10 min)  
-40 °C, 2 h  
+25 °C  
Converter  
operating  
Duration:  
Cooling test  
steady state  
EN 50155:2017, clause 13.4.4  
IEC/EN 60068-2-1  
Temperature, duration:  
Performance test:  
Converter  
not operating  
Salt mist test  
sodium chloride  
(NaCl) solution  
EN 50155:2017, clause 13.4.10 Temperature:  
IEC/EN 60068-2-11  
35 ±2 °C  
Converter  
not operating  
Duration:  
48 h  
Fc  
Fh  
Ea  
Vibration  
(sinusoidal)  
IEC/EN 60068-2-6  
MIL-STD-810D section 514.3  
Acceleration amplitude:  
0.35 mm (10 – 60 Hz)  
5 gn = 49 m/s2 (60 - 2000 Hz)  
10 – 2000 Hz  
Converter  
operating  
Frequency (1 Oct/min):  
Test duration:  
7.5 h (2.5 h in each axis)  
Random vibration  
broad band (digital  
control) & guidance  
IEC/EN 60068-2-64  
Acceleration spectral density: 0.05 gn2/Hz  
Frequency band:  
8 – 500 Hz  
Converter  
operating  
Acceleration magnitude:  
Test duration:  
4.9 gn  
rms  
1.5 h (0.5 h in each axis)  
50 gn = 490 m/s2  
11 ms  
Shock  
(half-sinusoidal)  
IEC/EN 60068-2-27  
MIL-STD-810D section 516.3  
Acceleration amplitude:  
Bump duration:  
Converter  
operating  
Number of bumps:  
Acceleration amplitude:  
Bump duration:  
18 (3 in each direction)  
5.1 gn  
Shock  
EN 50155:2017, clause 13.4.11  
EN 61373 sect. 10  
Converter  
operating  
30 ms  
class B, body mounted 1  
Number of bumps:  
18 (3 in each direction)  
2
Simulated long life  
testing at increased  
random vibration  
levels  
EN 50155:2017, clause 13.4.11  
EN 61373 sect. 8 and 9  
Acceleration spectral density: 0.02 gn /Hz  
Frequency band:  
Acceleration magnitude:  
Test duration:  
5 – 150 Hz  
Converter  
operating  
class B, body mounted 1  
0.8 gn rms  
15 h (5 h in each axis)  
1
Body mounted = chassis of a railway coach  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 24 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Temperatures  
Table 15: Temperature specifications, valid for an air pressure of 800 – 1200 hPa (800 – 1200 mbar)  
Model  
-2  
-7 (Option)  
-9  
Unit  
Characteristics  
Conditions  
min  
- 10  
- 10  
- 25  
typ  
max  
50  
min  
- 25  
- 25  
- 40  
typ  
max  
71 1  
951, 2  
85  
min  
- 40  
- 40  
- 55  
typ  
max  
71 1  
951, 2  
85  
TA  
TC  
TS  
Ambient temperature Converter operating  
Case temperature  
80  
° C  
Storage temperature Not operational  
85  
1
2
See Thermal Considerations. Operation with Po max requires a reduction to TA max = 50 °C and TC max = 85 °C.  
Overtemperature lockout at TC >95 °C (PTC).  
Reliability  
Table 16: MTBF and device hours  
Ratings at specified  
Model  
Ground benign  
Ground fixed  
40 °C 70 °C  
Ground mobile  
Naval,  
sheltered  
Device hours 1 Unit  
case temperature  
40 °C  
50 °C  
40 °C  
MTBF according to  
MIL-HDBK-217F  
CQ1000  
588 000  
196 000 96 000  
74 000  
6 400 000  
h
MTBF according to  
MIL-HDBK-217F, notice 2  
BQ1001-9R  
EQ2660-9R  
908 000  
913 000  
243 000 160 000  
237 000 155 000  
98 000  
97 000  
192 000  
188 000  
1
Statistical values, based on an average of 4300 working hours per year and in general field use over 5 years; upgrades and customer-induced  
errors are excluded.  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 25 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Mechanical Data  
The converters are designed to be inserted in a 19” rack according to IEC 60297-3. Dimensions in mm.  
20.3  
pin 4  
H
G
F
E
Key Code System  
A
B
C
D
Front plate  
Front plate  
104  
20  
Silkscreen  
without opt. Bx  
Silk-  
screen with  
opt. Bx  
M3; 5 deep  
Measuring point of  
case temperature TC  
AIRFLOW  
Main-  
face  
Rear-  
face  
Rear-  
face  
60  
1ꢀ.8  
38.8 *)  
Back plate  
111  
Standard  
Opt. B1  
104  
100  
*) 32.3 mm for opt. B  
**) 231.0 ...231.ꢀ mm  
for long case  
(add 5000 to the  
part number)  
ꢀ5  
= Ø 4.2  
= Ø 3.4  
= Ø 3  
LED ꢁIn-OKꢁ green1  
Potentiometer (option P)  
Test sockets1  
European  
Projection  
1 Not fitted to 48Q models  
LED ꢁOut-OKꢁ green  
Fig. 25  
Case Q01, weight approx.500 g;  
Aluminum, fully enclosed, black finish, EP powder coated, self cooling  
Notes:  
Long case, elongated by 60 mm for 220 mm rack depth is available on request. Add 5000 to the standard part number.  
An additional heat sink (option B1) is available; it reduces the case temperature TC, and allows more output power at higher ambient temperature TA.  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 26 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Safety and Installation Instructions  
Connector Pin Allocation  
The connector pin allocation table defines the electrical potentials and the physical pin positions on the H15 connector. Pin no. 26,  
the protective earth pin, is a leading pin, ensuring that it makes contact with the female connector first.  
Table 17: Pin allocation of the H15 connector  
Pin  
4
Electrical determination  
Output voltage (positive)  
Output voltage (positive)  
Output voltage (negative)  
Output voltage (negative)  
Sense line (positive) 2  
Q1000  
Vo+  
Vo+  
Vo-  
Q2000  
Vo1+  
Vo2+  
Vo1-  
Vo2-  
S+  
30  
26 22  
18 14 10  
6
6
8
10025a  
32  
28 24  
20 16  
12  
8
4
10  
12  
14  
16  
18  
20  
22  
24  
26  
28  
30  
32  
Vo-  
S+  
Sense line (negative) 2  
S-  
S-  
Fig. 26  
View of male H15 connector  
Output voltage adjust 1  
Current sharing control  
Do not connect (internal Gnd.)  
Output good signal (positive)  
R 1  
R 1  
T
T
-
-
Out OK +  
Out OK +  
Out OK -  
Output good signal (negative) Out OK -  
Protective earth PE2  
Inhibit control input3  
i
i
Input voltage (positive)  
Input voltage (negative)  
Vi+  
Vi-  
Vi+  
Vi-  
1
2
3
Do not connect pin 16 for models with 3.3 V output or with opt. P !  
Leading pin (pre-connecting).  
If not actively used, connect with pin 32.  
Installation Instructions  
The Q Series converters are components, intended exclusively for inclusion within other equipment by an industrial assembly  
operation or by professional installers. Installation must strictly follow the national safety regulations in compliance to enclosure,  
mounting, creepage, clearance, casualty, markings and segregation requirements of the end-use application.  
Connection to the system shall be made via the female connector H15 (see Accessories). Other installation methods may not  
meet the safety requirements.  
The Q Series converters are provided with pin 26 ( ), which is reliably connected to the case. For safety reasons it is essential  
to connect this pin to protective earth; see Safety of Operator-Accessible Output Circuits.  
The Vi– input (pin 32) is internally fused (except converters with option F). This fuse is designed to protect in case of overcurrent  
and may not be able to satisfy all customer requirements. External fuses in the wiring to one or both input pins (no. 30 and/or no.  
32) may be necessary to ensure compliance with local requirements.  
Important:  
• If the inhibit function is not used, pin 28 (i) must be connected with pin 32 (Vi–) to enable the output(s).  
• Do not open the converters, or warranty will be invalidated.  
• Long input, output and auxiliary lines, or lines with inductors, filters or coupling/decoupling networks may cause instabilities. See Input  
Stability with Long Supply Lines.  
Due to high output currents, the Q1001/1101 models offer two internally parallel-connected contacts for both, the positive and the  
negative output path (pins 4/6 and pins 8/10). It is recommended to connect the load to both female connector pins of each path  
in order to keep the voltage drop to a minimum.  
Make sure that there is sufficient air flow available for convection cooling. This should be verified by measuring the case temperature  
when the converter is installed and operated in the end-user application. The maximum specified case temperature TC max shall not  
be exceeded. See also Thermal Considerations.  
Ensure that a converter failure (e.g. by an internal short-circuit) does not result in a hazardous condition. See also Safety of  
Operator-Accessible Output Circuits.  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 27 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Cleaning Liquids and Protection Degree  
In order to avoid possible damage, any penetration of cleaning fluids must be prevented, since the power supplies are not  
hermetically sealed.  
Protection degree (female connector fitted to the converter):  
IP 30: All models, except those with option P (potentiometer)  
IP 20: All models with option P.  
Standards and Approvals  
The Q Series converters correspond to class I equipment. They are safety-approved to UL/CSA 60950-1 and IEC/EN 60950-1  
2nd Edition.  
The converters have been evaluated for:  
Building in  
Basic insulation between input and case and double or reinforced insulation between input and output, based on their maximum  
rated input voltage  
Basic insulation between Out-OK and case, and double or reinforced insulation between Out-OK and input and between Out-OK  
and output, based on their maximum rated input voltage  
Functional insulation between outputs and output to case  
Use in a pollution degree 2 environment  
Connecting the input to a circuit, which is subject to a maximum transient rating of 1500 V.  
CB Scheme is available.  
The converters are subject to manufacturing surveillance in accordance with the above mentioned standards and with ISO 9001:2015.  
Railway Applications  
The converters have been designed observing the railway standards EN 50155:2017 and EN 50121-3-2:2016. All boards are  
coated with a protective lacquer.  
The Q Series converters have been certified to the fire protection class HL1 to HL3 according to EN 45545.  
Isolation  
The electric strength test is performed in the factory as routine test according to EN 50514 and IEC/EN 60950. The company will  
not honor warranty claims resulting from incorrectly executed electric strength field tests. The resistance of the earth connection  
to the case (<0.1 ) is tested as well.  
Table 18: Isolation  
Characteristics  
Input to  
Case + Output(s)  
Output(s) to  
Case  
Output to  
Output  
Out-OK to  
Case + Input  
Out-OK to  
Output(s)  
Unit  
Electric  
strength test  
Factory test 10 s  
2.11  
2.1  
0.5 *  
0.35 *  
>100  
2.11  
2.11  
kVDC  
kVAC  
AC test voltage equivalent  
to factory test  
1.5 1  
1.5  
1.5 1  
1.5 1  
Insulation resistance  
>3002  
1.4 3  
>3002  
1.4  
>3002  
>3002  
MΩ  
Minimum creepage distances  
mm  
*
Models with version V104 or higher. Older converters have only been tested with 0.3 kVDC.  
In accordance with EN 50116 and IEC/EN 60950, subassemblies connecting input to output are pre-tested with 3 kVAC or 4.2 kVDC.  
Tested at 500 VDC.  
2.8 mm between input and output.  
1
2
3
Safety of Operator-Accessible Output Circuits  
If the output circuit of a DC-DC converter is operator-accessible, it shall be an SELV circuit according to IEC 60950.  
Table 20 shows some possible installation configurations, compliance with which causes the output circuit of the DC-DC converter  
to be SELV up to a configured output voltage (sum of nominal voltages, if in series configuration) of 35 V.  
However, it is the sole responsibility of the installer to ensure the compliance with the relevant and applicable safety regulations.  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 28 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Description of Options  
Option P: Output Voltage Adjustment  
Option P provides a built-in multi-turn potentiometer, which allows an output voltage adjustment of ±10% of Vo nom. The potentiometer  
is accessible through a hole in the front cover.  
With double-output models, both outputs are affected by the potentiometer. If converters are parallel-connected, their individual  
output voltage should be set within a tolerance of ±1%.  
If Vo is set higher than Vo nom, the output currents should be reduced accordingly, so that the maximum specified output power is  
not exceeded.  
Option -7: Temperature Range  
Option -7 designates converters with an operational ambient temperature range of 25 to 71 °C. Not for new designs.  
Option B, B1: Additional Heat Sink  
Thickness: 12.5 mm (opt. B) or 20 mm (opt. B1)  
Table 19: Thermal resistance case to ambient (approx. values)  
Case  
Thermal resistance Thickness of case  
Standard (160 mm long) 1.60 K/W  
< 20 mm  
< 20 mm  
< 33 mm  
< 40 mm  
Case 220 mm long1, 2  
Option B  
1.40 K/W  
1.45 K/W  
1.40 K/W  
Option B1  
1 As well available with an additional heat sink  
2 Customer-specific models. Add 5000 to the part number!  
Option F:  
No internal fuse; the installer must use an appropriate external fuse or circuit breaker. CSA, NEMKO symbol on request.  
Option non-G:  
Leaded solder used (not RoHS-compliant).  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 29 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Table 20: Safety concept leading to an SELV output circuit  
Conditions  
Front end  
DC-DC converter  
Result  
Nominal supply  
voltage  
Minimum required grade of  
insulation, to be provided by  
the AC-DC front end, including  
Maximum  
DC output  
voltage from  
Minimum required safety Types  
status of the front end  
output circuit  
Measures required to achieve  
the specified safety status of the of the DC-DC  
output circuit  
Safety status  
converter  
output circuit  
mains supplied battery charger the front end1  
Mains ≤150 VAC  
Functional (i.e. there is no need  
for electrical insulation between  
the mains supply circuit and the  
DC-DC converter input voltage)  
≤ 150 V2  
Primary circuit  
DQ  
EQ  
Double or reinforced insulation,  
based on 150 VAC and DC  
(provided by the converter) and  
earthed case3  
SELV circuit  
Basic  
≤ 60 V  
≤ 75V  
ELV circuit  
BQ, GQ  
48Q, CQ  
Supplementary insulation,  
based on 150 VAC (provided by  
the DC-DC converter) and earthed  
case3  
Hazardous voltage  
secondary circuit  
48Q  
CQ  
Supplementary insulation, based  
on 150 VAC and double or  
reinforced insulation4  
(both provided by the DC-DC  
converter) and earthed case3  
Mains ≤ 250 VAC  
≤ 60 V  
Earthed SELV circuit3  
ELV circuit  
BQ  
Functional insulation  
(provided by the converter)  
GQ  
48Q  
CQ  
Input fuse5, output suppressor  
Earthed SELV  
diodes6, earthed output circuit3 and circuit  
earthed3 or non-user-accessible  
case  
≤ 75V  
Unearthed hazardous  
voltage secondary circuit  
48Q  
CQ  
≤ 150 V  
Earthed hazardous  
BQ, GQ  
Double or reinforced insulation 4,  
(provided by the converter) and  
earthed case3  
SELV circuit  
voltage secondary circuit3 48Q, CQ  
or earthed ELV circuit  
DQ, EQ  
Unearthed hazardous  
voltage secondary circuit  
DQ  
EQ  
Supplementary insulation, based  
on 250 VAC and double or  
reinforced insulation4  
(both provided by the converter)  
and earthed case3  
Double or reinforced  
≤ 60 V  
SELV circuit  
TNV-3 circuit  
BQ, GQ  
48Q, CQ  
Functional insulation  
(provided by the converter)  
≤ 120 V  
≤ 150 V  
48Q, CQ  
DQ, EQ  
Basic insulation4  
(provided by the DC-DC converter)  
Double or reinforced  
insulated unearthed  
hazardous voltage  
secondary circuit2  
1
The front end output voltage should match the specified input voltage range of the DC-DC converter.  
Has to be insulated from earth according to IEC/EN 60950, by at least supplementary insulation, based on the maximum nominal output  
voltage from the front end.  
The earth connection has to be provided by the installer according to IEC/EN 60950.  
Based on the maximum rated output voltage provided by the front end.  
The installer shall provide an approved fuse with the lowest rating suitable for the application in a non-earthed input conductor directly at  
the input of the DC-DC converter (see fig. Schematic safety concept). For UL’s purposes, the fuse needs to be UL-listed.  
Each suppressor diode should be dimensioned such that in the case of an insulation fault the diode is able to limit the output voltage to  
SELV (<60 V), until the input fuse blows (see fig. Schematic safety concept).  
2
3
4
5
6
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 30 of 31  
Q Series  
66 - 132 W DC-DC Converters  
Accessories  
A variety of electrical and mechanical accessories are available:  
Various mating connectors including fast-on, screw, solder, or press-fit terminals, code key system; see Mating Connectors  
data sheet BCD.20022.  
Connector retention brackets (HZZ01217-G) CRB-Q  
Cable connector housings (cable hoods) HZZ00141-G, also available with fixation HZZ00142-G, and metallic cable hood HZZ00143-G.  
Front panels, system Schroff, for 19" racks in 3 U configuration 4 TE (G04-Q01), 5 TE (G05-Q01), or 6 TE (G06-Q01).  
Similar panels system Intermas available.  
Front panels, system Schroff, for 19" racks in 6 U configuration 5 TE (G05-6HE-Q01)  
Mechanical mounting supports for chassis, DIN-rail, and PCB mounting plate Q (HZZ01215-G) with retention clips Q (HZZ01229-G)  
Brackets for DIN-rail mounting UMB-LHMQ (HZZ00610-G)  
Additional external input and output filters  
Battery sensor [S-KSMH...] for using the converter as battery charger. Different cell characteristics can be selected.  
For additional accessory product information, see the accessory data sheets listed with each product series or individual  
model at our website.  
H15 female connector, code key system, Connector  
faston, screw or other terminals  
retention bracket  
(HZZ01217-G)  
Mounting plate with fitted metallic cable hood with fastening  
screws (HZZ00143-G)  
Mounting plate Q (HZZ01215-G) for wall mounting with fitted  
connector retention clips Q (HZZ01229-G)  
Universal mounting bracket for DIN-rail and chassis mounting  
(HZZ00610-G).  
Front panel kit G05-6HE-Q01 (HZZ00838) accommodating  
two units for a 19” DIN-rack with 6 U, 5 TE.  
NUCLEAR AND MEDICAL APPLICATIONS - These products are not designed or intended for use as critical components in life support systems,  
equipment used in hazardous environments, or nuclear control systems.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the  
date manufactured. Specifications are subject to change without notice.  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD20011 Rev AL1, 08-Aug-2018  
© 2018 Bel Power Solutions & Protection  
Page 31 of 31  

相关型号:

BQ2660-9P

DC-DC Regulated Power Supply Module, 2 Output, 106W, Hybrid, METAL, CASE Q01, MODULE
BEL

BQ2660-9R

DC-DC Regulated Power Supply Module, 2 Output, 132W, Hybrid, METAL, CASE Q01, MODULE
BEL

BQ2660-9RF

DC-DC Regulated Power Supply Module, 2 Output, 132W, Hybrid, PACKAGE-32/15
BEL

BQ2660-9RFG

DC-DC Regulated Power Supply Module, 2 Output, 132W, Hybrid, PACKAGE-32/15
BEL

BQ2660-9RG

DC-DC Regulated Power Supply Module,
BEL

BQ27000

SINGLE CELL Li-Ion AND Li-Pol BATTERY GAS GAUGE IC FOR PORTABLE APPLICATIONS (bqJUNIOR)
TI

BQ27000DRKR

SINGLE CELL Li-Ion AND Li-Pol BATTERY GAS GAUGE IC FOR PORTABLE APPLICATIONS (bqJUNIOR)
TI

BQ27000DRKRG4

SINGLE CELL Li-Ion AND Li-Pol BATTERY GAS GAUGE IC FOR PORTABLE APPLICATIONS (bqJUNIOR)
TI

BQ27000EVM

bq27000 Single Cell Battery Fuel Gauge Evaluation Module
TI

BQ27000PW

SINGLE-CELL LHON AND LI-POL BATTERY GAS GAUGE IC FOR PORTABLE APPLICATIONS
TI

BQ27000PWR

SPECIALTY ANALOG CIRCUIT, PDSO8, PLASTIC, TSSOP-8
TI

BQ27000_06

SINGLE CELL Li-Ion AND Li-Pol BATTERY GAS GAUGE IC FOR PORTABLE APPLICATIONS (bqJUNIOR)
TI