The ACC600 Series of open frame power supplies feature a wide
universal AC input range of 85 – 264 VAC, offering up to 600 W of
output power with convection cooling (U-Channel), in a compact
footprint, with a variety of single output voltages.
The high efficiency and high power density of the ACC series ensures
minimal power loss in end-use equipment, thereby facilitating higher
reliability, easier thermalmanagementand meets regulatory approvals
for environmentally-friendlyend products.
These power supplies are ideal for medical, telecom, datacom,
industrial equipment and other applications.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
5 x 8.5 x 1.61 Inch Form Factor (127 x 216 x 41 mm)
Convection Cooling Rated
Universal Input
Current Sharing Option
Peak Power Capability
5 VDC Stand by output
12 V fan output
Power Good / Power Fail Signal
Suitable in POE applications
Lesser than 1U high
High voltage output range up to 58 VDC
N+1 redundant power supply
Single wire current sharing
Built in OR-ing diode / FET (- R suffix)
•
•
•
•
Instrumentation
Lighting
•
•
•
•
Renewable Energy
Test and Measurement
Robotics
Industrial Applications
Applied Computing
Wireless Communication
2
ACC600 Series
ACC600-1T12
U-Channel
25 A
17.5 A
15 A
ACC600-1T12-H
ACC600-1T12-P
ACC600-1T15
ACC600-1T15-H
ACC600-1T15-P
ACC600-1T24
ACC600-1T24-H
ACC600-1T24-P
ACC600-1T30
ACC600-1T30-H
ACC600-1T30-P
ACC600-1T48
ACC600-1T48-H
ACC600-1T48-P
ACC600-1T58
ACC600-1T58-H
ACC600-1T58-P
12 V
15 V
24 V
30 V
48 V
58 V
U-Channel + Slotted Cover
U-Channel + Plain Cover
U-Channel
U-Channel + Slotted Cover
U-Channel + Plain Cover
U-Channel
U-Channel + Slotted Cover
U-Channel + Plain Cover
U-Channel
U-Channel + Slotted Cover
U-Channel + Plain Cover
U-Channel
U-Channel + Slotted Cover
U-Channel + Plain Cover
U-Channel
U-Channel + Slotted Cover
U-Channel + Plain Cover
0.0 A
0.0 A
0.0 A
0.0 A
0.0 A
0.0 A
2%
2%
2%
2%
2%
2%
25 A
17.5 A
15 A
25 A
17.5 A
15 A
20 A
14 A
12 A
12.5 A
8.75 A
7.5 A
10.34 A
7.25 A
6.2 A
1
To order product without theredundancy diode option pleaseadd thesuffix-Sxxxto your requiredpart number.
Please contact thefactory for availability.
For Ripplemeasurement minimumoutput power requirement is 25 W.
2
Ripple is peak to peak with 20 MHz bandwidth and10 µF (Electrolyticcapacitor)in parallel with a 0.1 µF capacitor at rated linevoltageand
load ranges.
Specifications are for nominal input voltage, 25°C unless otherwise stated.
Input Voltage
Universal
85 – 264 VAC / 120 – 390 VDC
47 – 63 Hz
Input Frequency
Input Current
120 VAC:
240 VAC:
6.5 A max.
3.2 A max.
Input Protection
No Load Power
In Live & Neutral both
F16 A / 250 V
Over entire input range with main output kept
OFF using RemoteON/OFF
3 W typ.
Inrush Current
Leakage Current
Touch Current:
240 VAC:
25 A max.
400 µA
240 VAC / 50 Hz
< 100 µA
120 VAC:
240 VAC:
0.98
0.95
Power Factor
PFC converter: Variable
Resonant converter: Variable
85 kHz typical
100 kHz typical
Switching Frequency
tech.support@psbel.com
3
ACC600 Series
Output Voltage
Standby Output Voltage3
Refer to Model Selection table for details
12 V to 58 V
5 V
U-Channel
U-Channel + Slotted Cover
U-Channel + Plain Cover
600 W
Output Power4
Convection Cooled
420 W
360 W
120 VAC:
240 VAC:
88% Typical
93%
Efficiency
Hold-up Time
Line Regulation
Load Regulation
120 VAC / 240 VAC:
8 ms
± 0.5%
± 1.0%
< 10%,
recovery time < 5 ms
Transient Response
50% to 100% load change, 50 Hz, 50% duty cycle, 0.1 A/μs
Voltage Adjustment
Set Point Tolerance
Rise Time
± 3%
± 1%
<100 ms
110%
114%
Over Current Protection
Over Voltage Protection
Short Circuit Protection
Over Temperature Protection
Current Share
Hiccup Type, autorecovery
Latch Type, AC Power to be recycled for recovery
Latch Type, AC Power to be recycled for recovery
Autorecovery
130 - 140°C primary heat sink
Up to 3 supplies connected in parallel (optional)
U-Channel
Convection
600 W
420 W
360 W
Cooling
U-Channel + Slotted Cover
U-Channel + Plain Cover
3
Standby output voltage5 V / 1.5 A (convection)with toleranceincluding set point accuracy, lineand loadregulation is +/-10%.Rippleand
noiseis less than 5%.
Combinedoutput power of main output,fan supply and standby supply shall not exceed max. power rating.
4
Conducted Emissions
Radiated Emissions
EN 55032
EN 55032
Class B
Class A
Class B
With External king core K5BRC 25x12x15-M or equivalent:
Input Current Harmonics
Voltage Fluctuation and Flicker
ESD Immunity
EN 61000-3-2
EN 61000-3-3
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
Class A
Pass
A
Radiated Field Immunity
Electrical Fast Transient Immunity
Surge Immunity
A
A
A
Conducted Immunity
A
Magnetic Field Immunity
Voltage Dips, Interruptions
A
A & B
North America
Asia-Pacific
Europe, Middle East
+86 755 298 85888
+353 61 225 977
+1 408 785 5200
© 2020 Bel Power Solutions & Protection
BCD.00970_B
4
ACC600 Series
Input to Output
Input to Earth
4000 VDC
2500 VDC
Isolation Voltage
IEC/EN 62368-1, ED 2
Safety Standard(s)
Agency Approvals
CE mark
UL 62368-1, CSA C22.2 No. 62368-1
Nemko, UL, C-UL
Complies with LVD Directive
Operating Temperature
Storage Temperature
Relative Humidity
Refer to derating curves
Non-condensing
-40 to +70°C
-40 to +85°C
5% to 95%
Operating:
Non-operating:
16,000 ft.
40,000 ft.
Altitude
MTBF
Telcordia -SR332-issue 3
3.37 million hours
Power Good: Is a TTL signal which goes high after mainoutput reaches 90% of its set value.
The delay is 0.1 s to 0.5 s
Power Good / Fail Signal
Remote Sense
Power Fail: Thesame signal goes low at least 1ms beforemain output falls to 90% ofset value at AC Power off
Compensates for 200 mV drop
Pin 6 & Pin 7 of J3 can be used for Remoteon/off.
Shorting Pin 6 to Pin 7 enables main output while keeping the pins open disables main output
Note: Provision of Inhibit RemoteON/OFF is available. +5 V at Pin 7 will switch offthe main output.
Remote On / Off
OCP Limit Set
Pin 8 & Pin 9 of J3 must be left open
Figure 1. Power Good / Fail Signal Diagram
tech.support@psbel.com
5
ACC600 Series
Pin 1
Pin 2
Pin 3
AC Line
Neutral
Earth
AC Input Connector
DC Output Connector
J1
J2
TE Connectivity: NC6-P107-03
6-32 inches Screw Pan HD
Mating: Designed to accept Ring Tongue Terminal AMP: 8-31886-1,
wherein one 16 AWG (max) wire can be crimped.
Note: One Ring TongueTerminal with 16 AWG is recommended for
current up to 11 A only.
J2-A
J2-B
+VE
-VE
Use multiple tongue terminals with wire for more current.
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
Pin 9
Pin 10
GND
5V AUX
PGPF
VS –
VS +
GND
RMT
CL2
Molex: 22-23-2101
Mating: 22-01-2107; Pins: 08-50-0113
Signal Connector
J35
CL1
LS
TE Connectivity AMP Connectors
Description: CONN HEADERVERT 2 POS 2.54 mm,
Pin 1
Pin 2
+VE
-VE
Fan Output6
J10, J11
MPN: 640456-2
Mating: 3-641535-2 / TE Connectivity AMP Connectors
or: 0022013027 / MOLEX with crimping 08-50-0114 / MOLEX
5
PSU is suppliedwith J3, pin-6 andpin-7 shortedto enable main output without remoteon/off feature.
Fan supply output voltageis 12 V / 500 mA with regulation band+/-30 % andRippleis less than 10%. To get 12 V Fan supply output voltage,
minimum10 % load on Main output voltageis required.
6
Weight
Dimensions
1100 g
127 x 216 x 41 mm (5.0 x 8.5 x 1.61 inches)
North America
Asia-Pacific
Europe, Middle East
+86 755 298 85888
+353 61 225 977
+1 408 785 5200
© 2020 Bel Power Solutions & Protection
BCD.00970_B
6
ACC600 Series
Figure 2. Mechanical drawing - U-Channel
tech.support@psbel.com
7
ACC600 Series
Figure 3. Mechanical drawing - U-Channel + Slotted Cover
North America
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
+1 408 785 5200
© 2020 Bel Power Solutions & Protection
BCD.00970_B
8
ACC600 Series
Figure 4. Mechanical drawing - U-Channel + Plain Cover
tech.support@psbel.com
9
ACC600 Series
Figure 5. Power Derating w.r.t. Input
Figure 6. Power Derating Curve 12 V
Convection load: 300 W up to 30 °C
De-rate between 30-50 °C @ 0.833% per °C
De-rate above 50 °C @ 2.5% per °C
Figure 7. Power Derating Curve 12 V with Slotted Cover
Figure 8. Power Derating Curve 12 V with Plain Cover
Convection load: 210 W up to 30 °C
De-rate between 30-50 °C @ 0.833% per °C
De-rate above 50 °C @ 2.5% per °C
Convection load: 180 W up to 30 °C
De-rate between 30-50 °C @ 0.833% per °C
De-rate above 50 °C @ 2.5% per °C
North America
Asia-Pacific
Europe, Middle East
+86 755 298 85888
+353 61 225 977
+1 408 785 5200
© 2020 Bel Power Solutions & Protection
BCD.00970_B
10
ACC600 Series
Figure 9. Power Derating Curve 15 V
Convection load: 375 W up to 30 °C
De-rate between 30-50 °C @ 0.8133% per °C
De-rate above 50 °C @ 2.5% per °C
Figure 10. Power Derating Curve 15 V with Slotted Cover
Figure 11. Power Derating Curve 15 V with Plain Cover
Convection load: 262.5 W up to 30 °C
De-rate between 30-50 °C @ 0.833% per °C
De-rate above 50 °C @ 2.5% per °C
Convection load: 225 W up to 30 °C
De-rate between 30-50 °C @ 0.833% per °C
De-rate above 50 °C @ 2.5% per °C
tech.support@psbel.com
11
ACC600 Series
Figure 12. Power Derating Curve 24 V and above
Convection load: 600 W up to 30 °C
De-rate between 30-50 °C @ 0.833% per °C
De-rate above 50 °C @ 2.5% per °C
Figure 13. Power Derating Curve 24 V and above with Slotted Cover
Figure 14. Power Derating Curve 24 V and above with Plain Cover
Convection load: 420 W up to 30 °C
De-rate between 30-50 °C @ 0.833% per °C
De-rate above 50 °C @ 2.5% per °C
Convection load: 360 W up to 30 °C
De-rate between 30-50 °C @ 0.833% per °C
De-rate above 50 °C @ 2.5% per °C
North America
Asia-Pacific
Europe, Middle East
+86 755 298 85888
+353 61 225 977
+1 408 785 5200
© 2020 Bel Power Solutions & Protection
BCD.00970_B
12
ACC600 Series
During the installation and setup of parallel supplies in a system it is important that a single remote sense point be used for all the
supplies. The remote sense voltage between the supplies must be adjusted to within 1% to ensure the supplies are inside the 1%
capture window. If the supplies are not initially adjusted inside the capture window the supplies will not current share satisfactorily.
SET-UP PROCEDURE:
1. Connect load cables to the outputs of each supply.
2. Connect the remote sense lines to the load in twisted style. (A common remote sense point must be used for all the supplies
in parallel).
3. Connect all the “LS” signal (Pin 10) on the J3 connector between the supplies.
4. Adjust remote sense voltage of each supply to within 1% of rated output voltage or readjust to required set point. (Adjustment
to be done with all other parallel supplies off).
5. Current sharing between the supplies can be verified by monitoring the output current of each supply with a hall effect DC
current probe. The supplies should share to within 10% of the total load current.
6. The current share circuit has a capture window voltage of +/- 1% of the rated output voltage. If the output remote sense
voltage of one of the supplies is adjusted outside the 1% window the supplies will not current share satisfactorily.
Figure 15. Current Sharing Block Diagram
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for useas critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
tech.support@psbel.com
相关型号:
©2020 ICPDF网 联系我们和版权申明