ABC200-1024G [BEL]
High Efficiency up to 91% at 230 VAC;型号: | ABC200-1024G |
厂家: | BEL FUSE INC. |
描述: | High Efficiency up to 91% at 230 VAC 局域网 输出元件 |
文件: | 总11页 (文件大小:1407K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
ABC200 Series is a family of compact and efficient AC-DCpower
supplies suited for telecom datacom and many other industrial
applications.
This family meets the international informationtechnology safety
standards with the CE-Mark for the European Low Voltage Directive
(LVD).
Their high efficiency allows a very minimal power loss in end
equipment, resulting in higher reliability, ease of thermal management
and regulatory approvalsfor an environmentally friendly end product.
•
•
•
•
High Efficiency up to 91% at 230 VAC
Universal AC Input Voltage Range: 90-264 VAC
Active Power Factor Correction
Over temperature, output overvoltage, overcurrent and short circuit
protection
•
•
EMC Standard according to EN 55032
Safety approved to the latest edition of the following standards:
CSA/UL 60950-1, EN/IEC 62368-1
•
•
•
•
High Power Density Design: 15 W/in3
Compact Size: 2.0 (W) x 4.0 (L) x 1.5 (H) inches
RoHS Compliant
CE Marked
•
•
•
Industrial Applications
Telecom
Datacom
2
ABC200 Series
MODEL
INPUT VOLTAGE
90 – 264 VAC
90 – 264 VAC
90 – 264 VAC
OUTPUT VOLTAGE
12 VDC
NOM OUTPUT CURRENT # OF OUTPUTS
OUTPUT POWER
200 W
ABC200-1012G
ABC200-1024G
ABC200-1048G
15 A
8.5 A
4.2 A
1
1
1
24 VDC
200 W
48 VDC
200 W
The ABC200-10XXG is a high efficiency and high power With 1 m/s system air cooling, the ABC200-1012G can density AC to DC
power supply. It incorporates boundary deliver up to 180 W continuous output power, and 204W for conduction mode (BCM) PFC
converter and soft-switching ABC200-1024G and the ABC200-1048G. LLC converter, providing increased system reliability and
high efficiency.
Figure 1. ABC200-10XXG block diagram
Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely affect long-term reliability, and
cause permanent damage to the supply.
PARAMETER
Vi maxc Max Continuous Input
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNIT
Continuous
Transient, 60 ms
264
300
VAC
VAC
tech.support@psbel.com
3
ABC200 Series
General Condition: TA = -10… 50 °C unless otherwise noted. Active fan air cooling required: 200 LFM (1 m/s)
PARAMETER
CONDITIONS / DESCRIPTION
MIN
100
90
NOM
MAX
240
UNIT
VAC
VAC
Arms
Vi nom Nominal Input Voltage
Vi
Input Voltage Ranges
Normal operating (Vi min to Vi max
)
264
Ii max Max Input Current
At 90 VAC input and max rating
2.75
Vi nom = 115 VAC, T = 25°C (see Figure 2)
Vi nom = 230 VAC, T = 25°C (see Figure 3)
40
80
Ii p
Inrush Current Limitation
Ap
Fi
Input Frequency
Power Factor
47
0.9
85
50/60
63
Hz
PF
Normal input, half load and above
Ramping up
Vi on Turn-On Input Voltage1
Vi off Turn-Off Input Voltage1
87
83
89
91
90
85
VAC
VAC
Ramping down
80
Vi nom = 230 VAC, 0.5∙Io nom, Vo nom, TA = 25 °C
Vi nom = 230 VAC, 1.0∙Io nom, Vo nom, TA = 25 °C
η
Efficiency
%
After last AC zero point, Vo within regulation,
Vi = 115 VAC, Po nom
Thold Hold-Up Time
10
ms
1) The power supply is provided with the hysteresis loop (about 4.5V) during turn-on and turn-offwithin the ranges.
A slow-blow 5A input fuse (5 × 20 mm) in series with live line inside the power supply protects against severe defects. The fuse
and a VDR form together with the input filter an effective protection against high input transients.
The AC-DC power supply exhibits an X-capacitance of only about 1.0 μF, resulting in a low and short peak current, when the
supply is connected to the mains. The internal bulk capacitor will be charged through a NTC resistor which will limit the inrush
current (see Figure 2 and 3).
Figure 2. Inrush current, Vin = 115Vac, 90° CH1: Vin (100V/div), CH2: Iin (10A/div)
1 The power supply is provided with the hysteresis loop (about 4.5V) during turn-on and turn-off within the ranges.
North America
Asia-Pacific
Europe, Middle East
+86 755 298 85888
+353 61 225 977
+1 408 785 5200
© 2020 Bel Power Solutions & Protection
BCD.G0201_AD
4
ABC200 Series
Figure 3. Inrush current, Vin = 230Vac, 90° CH1: Vin (200V/div), CH2: Iin (20A/div)
If the sinusoidal input voltage stays below the input under voltage lockout threshold Vi on, the supply will be inhibited. Once the
input voltage returns within the normal operating range, the supply will return to normal operation again.
Power factor correction (PFC) is achieved by controlling the input current waveform synchronously with the input voltage. A
specified PFC controller is implemented in the boundary conduction mode topology giving outstanding PFC results over a
wide input voltage and load ranges. The input current will follow the shape of the input voltage.
The high efficiency (see Figure 4) is achieved by using softs witching LLC technology with boundary conduction mode PFC
topology minimizing switching losses. Synchronous rectifiers on the output reduce the losses in the high current A Schottky
or ultra fast diode is used as the rectifier in the output path for ABC200-1012G. ABC200-1024G and ABC200-1048G because
of the high output voltage level.
Figure 4. Efficiency Curves
tech.support@psbel.com
5
ABC200 Series
General Condition: TA = -10 to +50°C unless otherwise noted. Derate linearly from 50°C to 50% at 70°C.
Active fan air cooling required: 200 LFM (1 m/s).
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM MAX UNIT
Main Output VO
ABC200-1012G
ABC200-1024G
ABC200-1048G
ABC200-1012G
ABC200-1024G
ABC200-1048G
ABC200-1012G
ABC200-1024G
ABC200-1048G
ABC200-1012G
ABC200-1024G
ABC200-1048G
ABC200-1012G
ABC200-1024G
ABC200-1048G
ABC200-1012G
ABC200-1024G
ABC200-1048G
ABC200-1012G
ABC200-1024G
ABC200-1048G
ABC200-1012G
ABC200-1024G
12.0
VO
Nominal Output Voltage
0.5 ∙IO, Tamb = 25 °C,
24.0
48.0
VDC
VDC
11.95
23.90
47.80
12.05
24.10
48.20
VO set Output Setpoint Accuracy 0.5 ∙IO, Tamb = 25 °C
180
204
204
13
W
W
PO
Nominal Output Power
Nominal Output Current
W
15
8.5
ADC
ADC
ADC
mV
mV
mV
mV
mV
mV
mV
mV
mV
VDC
VDC
IO
7.5
3.5
4.25
120
240
480
120
240
480
120
240
480
0.6
VO ripple Output Ripple & Noise
VO nom, IO nom, 20 MHz BW
Vi = Vi nom, 0 - 100 % IO nom,
Vi =Vi min…Vi max,
60
120
240
12
dVO
Load Regulation
dVi Line Line Regulation
24
96
ΔIO = 50% IO nom
,
IO = 50 … 100% IO max,
dIO/dt = 1 A/μs,
1.2
dVdyn Dynamic Load Regulation
recovery within 5% of VO nom
ABC200-1048G
ABC200-10XXG
2.4
VDC
Trec
Recovery Time
2
ms
sec
ms
t Delay Turn On Delay Time
See Figure 5 and Figure 6
0
1.5
2.5
20
VO = 10…90% VO nom (see Figure 10)
t rise Rise Time
Note: For ABC200-1048G, maximumrise time is 30 ms
ABC200-1012G
3300
1800
1000
μF
μF
μF
CLoad Capacitive Loading
Tamb = 25 °C
ABC200-1024G
ABC200-1048G
North America
Asia-Pacific
Europe, Middle East
+86 755 298 85888
+353 61 225 977
+1 408 785 5200
© 2020 Bel Power Solutions & Protection
BCD.G0201_AD
6
ABC200 Series
Figure 5. Turn-On AC Line 115 VAC, full load (500 ms/div)
CH1: VO (3 V/div) CH2: Vin (230 V/div)
Figure 6. Turn-On AC Line 230 VAC, full load (500 ms/div)
CH1: VO (3 V/div) CH2: Vin (350 V/div)
Figure 7. Turn-Off AC Line 115 VAC, full load (10 ms/div)
CH1: VO (3 V/div) CH2: Vin (230 V/div)
Figure 8. AC drop out 10ms (50 ms/div)
CH1: VO (3 V/div) CH2: Vin (250 V/div)
Figure 9. AC drop out 30ms (50 ms/div), VO restart
CH1: VO (3 V/div) CH2: Vin (250 V/div)
Figure 10. VO rise time at 115VACCH1: VO (2 V/div)
tech.support@psbel.com
7
ABC200 Series
Figure 11. Load transient VO, 7.5A to 15A (200 us/div), CH1: IO (5
A/div) CH2: VO (200 mV/div)
Figure 12. Load transient VO, 15A to 7 A (200 us/div)
CH1: IO (5 A/div) CH2: VO (200 mV/div)
PARAMETER
CONDITIONS / DESCRIPTION
Vi min to Vi max, Io nom, ISB nom
Derated output
MIN
-10
NOM
MAX
+50
+70
+85
UNIT
°C
TA
TAext
TS
Ambient temperature
Extended temp range
Storage temperature
+50
-40
°C
Non-operational
°C
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
5.0
MAX
UNIT
A
F
Input Fuses Rating
Not user accessible, time lag characteristic
ABC200-1012G
14.0
28.0
53.0
15.0
30.0
55.0
18.0
9.0
16.0
32.0
57.0
VDC
VDC
VDC
A
ABC200-1024G
ABC200-1048G
ABC200-1012G
ABC200-1024G
ABC200-1048G
Vo ov
OV Trigger Point
Io lim
A
Current Limit
Vi > 90 VAC, -10 °C <Ta < 50 °C
4.5
A
Over Temperature on
Heat Sinks
TSD
Automatic shut-down, automatic recovery after cooldown.
105
°C
North America
Asia-Pacific
Europe, Middle East
+86 755 298 85888
+353 61 225 977
+1 408 785 5200
© 2020 Bel Power Solutions & Protection
BCD.G0201_AD
8
ABC200 Series
The AC-DC power supply provides a fixed threshold overvoltage (OV) protection implemented with a HW comparator. Once
an OV condition has been triggered, the supply will shut down and latch the fault condition. The latch can be unlocked by
disconnecting the supply from the AC mains only.
The main output current limitation will decrease with linear derating to 50% at 70 ºC if the ambient (inlet) temperature increases
beyond 50 °C (see Figure 13).
Figure 13. Output Current Capacity Derating
The Out-OK output gives a status indication of the converter and the output voltages. It can be used for control functions such as
data protection, central system monitoring or as a part of a self-testing system. Connecting the Out-OK as shown in Figure 14,
VOK <1.0 V indicates the output voltage(s) of the converter are within the range.
Note: Using the potentiometer, the monitor level tracks the programmed output voltage. In an error condition, if the output voltage
is out of range due to overload or an external over voltage, VOK will approach Vp. The output is Figure 14: Power Good signal
formed by an NPN transistor. The signal is isolated from the output.
Figure 14. Power Good signal
tech.support@psbel.com
9
ABC200 Series
NOTE: Most of the immunity requirements are derived from EN 55024: 2010.
TEST
STANDARD / DESCRIPTION
EN 61000-4-2, Level 2
EN 61000-4-3, Level 3
EN 61000-4-4, Level 3
EN 61000-4-5, Class 3
EN 61000-4-6, Class 3
EN 61000-4-11
CRITERIA
ESD Contact Discharge
RF Susceptibility
Fast Transient/Burst
Surge
A
A
B
B
A
C
A
RF Conducted Immunity
Voltage Dips and Interruptions
Magnetic Fields
EN 61000-4-8, Level 3
TEST
STANDARD / DESCRIPTION
CRITERIA
Class A
Class A
Class A
Class A
PASS
Conducted Emission
Radiated Emission
EN 55032 / CISPR 22: 0.15 … 30 MHz, QP and AVG, single unit
EN 55032 / CISPR 22: 30 MHz … 1 GHz, QP, single unit
IEC 61000-3-2, Vin = 100 VAC/ 60 Hz, 100% Load
IEC 61000-3-2, Vin = 240 VAC/ 50 Hz, 100% Load
EN 61000-3-3
Harmonic Emissions
Voltage Fluctuation and Flicker
Maximum electric strength testing is performed in the factory according to IEC/EN 62368-1, and UL 60950. Input-to-output electric
strength tests should not be repeated in the field. Bel Power Solutions will not honor any warranty claims resulting from electric
strength field tests.
PARAMETER
Safety Approvals
DESCRIPTION / CONDITIONS
MIN
NOM
MAX
UNIT
Safety approved to the latest edition of the following standards:
CSA/UL60950-1, IEC/EN 62368-1
CE Mark for LVD
CB Approval
Input / Case
Basic
Insulation Safety Rating
dC Creepage / Clearance
Electrical Strength Test
Input / Output
Reinforced
Functional
Output / Case
Primary (L/N) to protective earth (PE)
Primary to secondary
Input to case
mm
mm
According to
safety standard
2121
4242
500
VDC
VDC
VDC
Input to output
Output and Signals to case
North America
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
+1 408 785 5200
© 2020 Bel Power Solutions & Protection
BCD.G0201_AD
10
ABC200 Series
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNIT
Width
Height
Depth
50.8
36.6
mm
mm
mm
Dimensions
Weight
101.6
M
0.2
kg
AIR FLOW DIRECTION
Figure 15. Side view 1
Figure 16. Side view 2
tech.support@psbel.com
11
ABC200 Series
Figure 17. Top view
Figure 18. Front view
NOTE: A 3D step file of the power supply casing is available on request.
PIN
NAME
DESCRIPTION
Input J1
J1-1
Live
AC Input Live
NA
J1-2
NA
J1-3
Neutral
AC Input Neutral
Output J2
Pin 1-3(Insider Row)
-Vo
+12V / +24V / +48V output return
+12V / +24V / +48V output
Pin 4-6(Outside Row)
+Vo
Signal J3
J3-1
Power Good RTN
Power Good
Vo Sense +
Power OK signal output return
Power OK signal output
J3-2
J3-3
Main output positive sense
Main output negative sense
J3-4
Vo Sense -
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for useas critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
North America
Asia-Pacific
Europe, Middle East
+86 755 298 85888
+353 61 225 977
+1 408 785 5200
© 2020 Bel Power Solutions & Protection
BCD.G0201_AD