20IMX35-12-12-8 [BEL]

DC-DC Regulated Power Supply Module, 2 Output, 35W, Hybrid;
20IMX35-12-12-8
型号: 20IMX35-12-12-8
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

DC-DC Regulated Power Supply Module, 2 Output, 35W, Hybrid

文件: 总18页 (文件大小:179K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Board Mountable  
DC-DC Converters  
IMX 35 Series  
35 Watt DC-DC Converters  
IMX 35 Series  
Wide input voltage ranges up to 75 V DC  
2...4 isolated outputs up to 60 V DC  
1500 V DC I/O electric strength test voltage  
• Immunity to IEC/EN 61000-4-2,-3,-4,-5 and -6  
• Programmable input undervoltage lock-out  
• Shut down input  
• Output voltages adjustable with flexible load  
distribution  
10.5  
0.41"  
63.5  
2.5"  
76.2  
3"  
• Frequency synchronisation  
• Outputs no-load, overload and short-circuit proof  
• Operating ambient temperature up to –40...85°C  
• Thermal protection  
• 3" × 2,5" case with 10.5 mm profile  
or 8.9 mm profile open frame  
• Supplementary insulation  
Safety according to IEC/EN 60950, UL 1950  
LGA  
Approvals pending  
8.9  
0.35"  
47.8  
1.88"  
72.8  
2.87"  
Summary  
The IMX 35 series of board mountable 35 Watt DC-DC con-  
verters has been designed according to the latest industry  
requirements and standards. The converters are particu-  
larly suitable for use in mobile or stationary applications in  
transport, railways, industry, or telecommunication where  
variable input voltages or high transient voltages are preva-  
lent.  
tion. Connected to a secondary circuit the 40 IMX 35 types  
feature SELV outputs even if the voltage at the converter in-  
put exceeds the SELV-limit of 60 V DC.  
The circuit comprises of two planar magnetics devices and  
all components are automatically assembled and solidly  
soldered onto a single PCB without any wire connection.  
Magnetic feedback ensures maximum reliability and  
repeatability in the control loop over all operating condi-  
tions. Careful considerations of possible thermal stresses  
ensure the absence of hot spots providing long life in envi-  
ronments where temperature cycles are a reality. The ther-  
mal design without using any potting material allows opera-  
tion up to an ambient temperature of –40...85°C in free air.  
For extremely high vibration environments the case has  
holes for screw mounting. Inhibit or open frame mounting  
provide a high level of application specific engineering and  
design-in flexibility.  
Covering a total input voltage range from 9 up to 75 V with  
2 different types. The units are available with double, triple  
and quad outputs, electrically isolated, from 3.3 V up to 60  
V externally adjustable and with flexible load distribution. A  
shut down input allows remote converter on/off. Features  
include consistently high efficiency over the entire input  
voltage range, high reliability and excellent dynamic re-  
sponse to load and line changes.  
The converters are designed and built according to the in-  
ternational safety standards IEC/EN 60950, UL 1950, CAN/  
CSA C22.2 No.950-95. LGA, UL and cUL approvals are in  
progress. The IMX 35 types provide supplementary insula-  
Table of Contents  
Page  
Page  
Auxiliary Functions ......................................................... 11  
Electromagnetic Compatibility (EMC) ............................ 13  
Immunity to Environmental Conditions........................... 14  
Mechanical Data ............................................................ 15  
Safety and Installation Instructions ................................ 16  
Description of Option...................................................... 18  
Summary .......................................................................... 1  
Type Survey and Key Data .............................................. 2  
Type Key .......................................................................... 3  
Functional Description...................................................... 4  
Electrical Input Data ......................................................... 6  
Electrical Output Data ...................................................... 8  
Edition 5/08.2001 R1  
1/18  
Board Mountable  
DC-DC Converters  
IMX 35 Series  
Type Survey and Key Data  
Table 1: Type survey  
Output 1  
Output 2  
Output 3  
Output 4  
Input voltage Eff.  
Type  
Trim 1 Opt. 2  
Uo nom Io nom Uo nom Io nom Uo nom Io nom Uo nom Io nom  
Ui min...Ui max htyp  
designation  
[V DC]  
[A]  
[V DC]  
[A]  
[V DC]  
[A]  
[V DC]  
[A]  
[V DC]  
[%]  
5
5
2.7  
2.8  
5
5
2.7  
2.8  
-
-
-
-
-
-
-
-
9...36  
18...75  
84  
84  
20 IMX 35-05-05-8  
40 IMX 35-05-05-8  
primary  
primary  
12  
12  
1.3  
1.4  
12  
12  
1.3  
1.4  
-
-
-
-
-
-
-
-
9...36  
18...75  
87  
87  
20 IMX 35-12-12-8  
40 IMX 35-12-12-8  
primary  
primary  
15  
15  
1.1  
1.2  
15  
15  
1.1  
1.2  
-
-
-
-
-
-
-
-
9...36  
18...75  
87  
87  
20 IMX 35-15-15-8  
40 IMX 35-15-15-8  
primary  
primary  
3.3  
3.3  
3.5  
4.25  
5
5
1.3  
1.35  
5
5
1.3  
1.35  
-
-
-
-
9...36  
18...75  
81  
83  
20 IMX 35-03D05-8 3 second. i, Y  
40 IMX 35-03D05-8 3 second. i, Z  
3.3  
3.3  
3.5  
4.25  
12  
12  
0.65  
0.7  
12  
12  
0.65  
0.7  
-
-
-
-
9...36  
18...75  
84  
86  
20 IMX 35-03D12-8 3 second. i, Y  
40 IMX 35-03D12-8 3 second. i, Z  
3.3  
3.3  
3.5  
4.25  
15  
15  
0.55  
0.6  
15  
15  
0.55  
0.6  
-
-
-
-
9...36  
18...75  
84  
86  
20 IMX 35-03D15-8 3 second. i, Y  
40 IMX 35-03D15-8 3 second. i, Z  
5.1  
5.1  
2.9  
3.4  
5
5
1.35  
1.4  
5
5
1.35  
1.4  
-
-
-
-
9...36  
18...75  
81  
83  
20 IMX 35-05D05-8 3 second. i, Y  
40 IMX 35-05D05-8 3 second. i, Z  
5.1  
5.1  
2.9  
3.4  
12  
12  
0.65  
0.7  
12  
12  
0.65  
0.7  
-
-
-
-
9...36  
18...75  
84  
86  
20 IMX 35-05D12-8 3 second. i, Y  
40 IMX 35-05D12-8 3 second. i, Z  
5.1  
5.1  
2.9  
3.4  
15  
15  
0.55  
0.6  
15  
15  
0.55  
0.6  
-
-
-
-
9...36  
18...75  
84  
87  
20 IMX 35-05D15-8 3 second. i, Y  
40 IMX 35-05D15-8 3 second. i, Z  
5
5
1.35  
1.4  
5
5
1.35  
1.4  
5
5
1.35  
1.4  
5
5
1.35  
1.4  
9...36  
18...75  
86  
87  
20 IMX 35 D05D05-8 primary  
40 IMX 35 D05D05-8 primary  
5
5
1.35  
1.4  
12  
12  
0.65  
0.7  
12  
12  
0.65  
0.7  
5
5
1.35  
1.4  
9...36  
18...75  
86  
88  
20 IMX 35 D05D12-8 primary  
40 IMX 35 D05D12-8 primary  
5
5
1.35  
1.4  
15  
15  
0.55  
0.6  
15  
15  
0.55  
0.6  
5
5
1.35  
1.4  
9...36  
18...75  
87  
88  
20 IMX 35 D05D15-8 primary  
40 IMX 35 D05D15-8 primary  
i, Z  
12  
12  
0.65  
0.7  
12  
12  
0.65  
0.7  
12  
12  
0.65  
0.7  
12  
12  
0.65  
0.7  
9...36  
18...75  
87  
89  
20 IMX 35 D12D12-8 primary  
40 IMX 35 D12D12-8 primary  
15  
15  
0.55  
0.6  
15  
15  
0.55  
0.6  
15  
15  
0.55  
0.6  
15  
15  
0.55  
0.6  
9...36  
18...75  
88  
89  
20 IMX 35 D15D15-8 primary  
40 IMX 35 D15D15-8 primary  
1 For the units IMX 35-05-05, IMX 35-12-12, IMX 35-15-15 and all the quad versions with equal output voltages, the Trim input (pin 5) is  
on the primary side and influences all outputs simultaneously while pin 18 is not connected. For the quad versions with unequal out-  
put voltages (e.g. 40 IMX 35 D05D12-8) the Trim input (pin 5) influences only the first power train i.e. V01 and V04. For the triple ver-  
sions the Trim input (pin 18) is on the secondary side and influences the first output (V01) only.  
2 For minimum quantity contact Power-One.  
3 For lead times contact Power-One.  
Edition 5/08.2001 R1  
2/18  
Board Mountable  
DC-DC Converters  
IMX 35 Series  
Type Key  
Double output units  
20 IMX 35 - 12 - 12 -8  
Input voltage range Ui  
9...36 V DC ........................................... 20  
18...75 V DC ........................................... 40  
Series ...................................................................... IMX 35  
Output 1 of double types (5, 12, 15 V) ............... 05, 12, 15  
Output 2 of double types (5, 12, 15 V) ............... 05, 12, 15  
Operating ambient temperature range TA  
40...85°C .................................................. -8  
Triple output units  
40 IMX 35 - 05 D05 -8 i Z  
Input voltage range Ui  
9...36 V DC ........................................... 20  
18...75 V DC ........................................... 40  
Series ...................................................................... IMX 35  
Output 1 of triple types (3.3, 5 V) ............................. 03, 05  
Output 2/3 of triple types (3.3, 5 V)............ D05, D12, D15  
Operating ambient temperature range TA  
40...85°C .................................................. -8  
Options:  
Inhibit ............................................................ i  
Base plated open frame ..............................Y 1  
Open frame .................................................. Z 2  
Quad output units  
40 IMX 35 D05 D05 -8 i Z  
Input voltage range Ui  
9...36 V DC ........................................... 20  
18...75 V DC ........................................... 40  
Series ...................................................................... IMX 35  
Output 1/4 of quad types (5, 12, 15 V)....... D05, D12, D15  
Output 2/3 of quad types (5, 12, 15 V) ...... D05, D12, D15  
Operating ambient temperature range TA  
40...85°C .................................................. -8  
Options:  
Inhibit ............................................................ i  
Open frame .................................................. Z 2  
1 20 IMX 35 triple output types.  
2 All models except 20 IMX 35-triple output types.  
Edition 5/08.2001 R1  
3/18  
Board Mountable  
DC-DC Converters  
IMX 35 Series  
Functional Description  
The IMX 35 family of DC-DC converters consists of two  
feedback controlled interleaved switching flyback power  
trains using current mode PWM (pulse width modulation).  
Functionally the converters are of three main types. The  
double output types consist of two electrically isolated out-  
puts Vo1, Vo2. Vo1 and Vo2 derive from two power trains  
and are electrically isolated. Voltage regulation for each  
output is achieved with passive transformer feedback from  
the main transformer of each power train. Adjustment of the  
outputs voltages in the range of 80...105% of Uo nom is pos-  
sible by use of the Trim input on the primary side (See:  
Block diagram, dual output types.)  
The quad output type consists of 4 outputs and two power  
trains. Vo1, Vo4 derive from the first power train and Vo2,  
Vo3 from the second one (thus each pair of outputs is inde-  
pendent from the other one). Voltage regulation for each  
pair of outputs is achieved with passive transformer feed-  
back from the main transformer of each power train. Each  
pair of outputs are restricted to being of the same output  
voltage type (i.e. D05, D12, etc.). If both power trains have  
the same output voltage, all outputs may be adjusted by  
means of the Trim input. (In case of different output volt-  
ages, the Trim1/4 input influences only Vo1 and Vo4. See:  
Block diagram, quad output types.)  
The triple output types consist of 3 outputs Vo1, Vo2 and  
Vo3. Vo1 (3.3 or 5.1 V) is generated by a power train using  
state of the art Schottky diode (20 IMX 35) or a synchro-  
nous rectifier technology (40 IMX 35) thus enabling high ef-  
ficiency. Also there is active magnetic feedback on this out-  
put via a pulse transformer which results in very tight and  
reliable regulation of the output voltage. The other two out-  
puts Vo2 and Vo3 are electrically isolated double outputs.  
Vo2, Vo3 are restricted to being of the same output voltage  
(i.e. D05, D12, etc.). Voltage regulation is achieved with a  
passive transformer feedback from the main transformer of  
that power train. Adjustment of the output 1 (Uo1) is pro-  
vided by the Trim1 pin referenced to the secondary side  
and allows for programming of the voltage of output 1 in the  
range of approx. 80...105% of Uo nom. (See: Block diagram,  
triple output types)  
Current limitation is provided by the primary circuit for each  
power train and limits the possible output power for each  
pair of outputs. In the case of an overload on either of the  
power trains which causes the output voltage to drop below  
typically 60% of Uo nom, the entire converter will shut down  
and automatically restart in short intervals.  
Overtemperature protection is provided, which will shut  
down the converter in excessive overload conditions with  
automatic restart.  
03100  
Vi+  
4
17  
Vo1+  
1
5
6
7
8
2
3
PUL  
15  
16  
18  
12  
Vo1–  
Trim  
W
1
PWM  
Ref  
SD  
1
1
Vi–  
n.c.  
13 Vo2+  
14  
11  
n.c.  
Vo2–  
19  
n.c.  
1 Internally connected, leave open-circuit  
Fig. 1  
Block diagram 1, double output types  
Edition 5/08.2001 R1  
4/18  
Board Mountable  
DC-DC Converters  
IMX 35 Series  
03097  
4
17  
Vi+  
Vo1+  
n.c.  
1
5
6
7
1
2
3
PUL  
n.c.  
W
16  
15  
Control  
Vo1–  
PWM  
Ref  
18  
13  
Trim1  
Vo2+  
SD  
Vi–  
n.c.  
14  
12  
Vo2–  
Vo3+  
11  
19  
Vo3–  
n.c.  
Fig. 2  
Block diagram 2, triple output types  
03098  
Vi+  
4
16  
Vo1+  
1
5
6
7
8
2
3
PUL  
15  
Vo1–  
Trim/Trim1/4  
17 Vo4+  
18 Vo4–  
13 Vo2+  
PWM  
W
Ref  
SD  
Vi–  
n.c.  
14  
12  
Vo2–  
Vo3+  
11 Vo3–  
19 n.c.  
Fig. 3  
Block diagram 3, quad output types  
Edition 5/08.2001 R1  
5/18  
Board Mountable  
DC-DC Converters  
IMX 35 Series  
Electrical Input Data  
General conditions:  
TA = 25°C, unless TC is specified.  
Shut down pin left open circuit (not connected).  
Trim not connected.  
Table 2: Input Data  
Input  
20 IMX  
40 IMX  
Characteristics  
Conditions  
min  
9 2  
typ  
max  
36  
min  
18 2  
typ  
max  
75  
Unit  
Ui  
Input voltage range 1  
TA min...TA max  
Io = 0...Io nom  
V DC  
Ui nom  
Ui sur  
tstart up  
Nominal input voltage  
20  
40  
Repetitive surge voltage  
Abs. max input (3 s)  
40  
0.5  
0.1  
100  
0.5  
0.1  
Converter  
start-up time 2  
Switch on  
SD high  
Worst case condition at  
Ui min and full load  
0.25  
0.25  
s
trise  
Rise time 3  
Ui nom resist load  
Io nom capac. load  
Io = 0, Ui min...Ui max  
Io = 0...Io nom  
5
5
ms  
mA  
10  
20  
70  
30  
8
10  
20  
50  
30  
9
Ii o  
No load input current  
Reflected ripple current  
Inrush peak current 4  
Input capacitance  
Iirr  
Iinr p  
Ci  
Ui = Ui nom  
A
for surge calculation  
Unit shut down  
Unit operating  
2
1.3  
µF  
USD  
Shut down voltage  
10...0.7  
10...0.7  
V DC  
open-circuit or 2...20  
open-circuit or 2...20  
RSD  
ISD  
Shut down input resistance For current calculations  
approx. 10  
12  
approx. 10  
6
kΩ  
Input current if unit  
shut down  
Ui min...Ui max  
mA  
fs  
Switching frequency  
Ui min...Ui max, Io = 0...Io nom  
EN 55022 5  
approx. 220  
B 6  
approx. 220  
B 6  
kHz  
ui RFI  
Input RFI level, conducted  
1 Ui min will not be as stated if Uo is increased above Uo nom by use of Trim input. If the output voltage is set to a higher value,  
Ui min will be proportionately increased.  
2 Input undervoltage lock-out at typ. 90% of Ui min  
.
3 Measured with resistive and max. admissible capacitive load.  
4 Source impedance according to prETS 300132-2, version 4.3.  
5 Measured with a lead length of 0.1 m, leads twisted.  
6 External capacitor required.  
Edition 5/08.2001 R1  
6/18  
Board Mountable  
DC-DC Converters  
IMX 35 Series  
Inrush current  
Input Transient Voltage Protection  
The inrush current has been kept as low as possible by  
choosing a very small input capacitance. A series resistor  
may be installed in the input line to further reduce this cur-  
rent.  
A built-in suppressor diode provides effective protection  
against input transients which may be caused for example  
by short-circuits accross the input lines where the network  
inductance may cause high energy pulses.  
04022  
Table 4: Built-in transient voltage suppressor  
I [A]  
Type  
Breakdown  
voltage  
VBr nom [V]  
Peak power  
at 1 ms  
Peak pulse  
current  
Ipp [A]  
4
3
2
Pp [W]  
20 IMX 35  
40 IMX 35  
50  
1500  
1500  
22  
100  
9.7  
1
t [µs]  
For very high energy transients as for example to achieve  
IEC/EN 61000-4-5 or ETR 283 (19 Pfl1) compliance (as per  
table: Electromagnetic Immunity) an external inductor and  
capacitor are required. The components should have simi-  
lar characteristics as listed in table: Components for exter-  
nal circuitry for IEC/EN 61000-4-5, level 2 or ETR 283  
(19Pfl1) compliance.  
0
20  
50 60 70 80 90 100  
10  
30 40  
Fig. 4  
Typical inrush current at Ui nom, Po nom versus time  
(40 IMX 35). Source impedance according to  
prETS 300132-2, version 4.3 at Ui nom  
.
Note: The suppressor diode D is only necessary for  
20 IMX 35 types.  
Uo  
trise  
04008  
Uo nom  
Table 5: Components for external circuitry for IEC/EN  
61000-4-5, level 2 or ETR 283 (19Pfl1) compliance.  
Type  
Inductor (L)  
22 µH/5A  
Capacitor (C)  
470 µF/40 V  
Diode (D)  
1.5 k E47A  
-
t
tstart up  
20 IMX 35  
40 IMX 35  
68 µH/2.7 A  
2 x 100 µF/100 V  
Fig. 5  
Converter start-up and rise time  
04036  
L
Reverse Polarity Protection  
Vi+  
The built-in suppressor diode also provides for reverse po-  
larity protection at the input by conducting current in the re-  
verse direction. An external fuse is required to limit this cur-  
rent.  
+
C
D
Vi–  
Table 3: Recommended external fuses  
Fig. 6  
Example for external circuitry to comply with IEC/EN  
61000-4-5 or ETR 283 (19Pfl1); the suppressor diode D is  
only necessary for 20 IMX 35 types.  
Converter type  
20 IMX 35  
Fuse type  
F8.0A  
40 IMX 35  
F4.0A  
22  
04052  
11.5  
Fig. 7  
23.8  
Dimensions of inductor L for 20 IMX 35 and 40 IMX 35  
types (e.g. Coil Craft, PCH-45 series).  
Edition 5/08.2001 R1  
7/18  
Board Mountable  
DC-DC Converters  
IMX 35 Series  
Electrical Output Data  
General conditions:  
TA = 25°C, unless TC is specified  
Shutdown pin left open-circuit (not connected)  
Trim not connected  
Table 6a: Output data for single (main) output.  
Output  
3.3 V  
5.1 V  
Characteristics  
Conditions  
min typ  
3.28  
max  
3.32  
min typ max  
Unit  
V DC  
A
Uo  
Output voltage  
Ui nom, Io = 0.5 Io nom  
20 IMX Ui min...Ui max  
40 IMX  
5.07  
5.13  
Io nom Output current  
3.5  
2.9  
3.4  
4.2  
4.25  
Io1L  
Io2L  
Current limit 1  
20 IMX Ui nom, TC = 25°C  
5.5  
Uo1 = 93% Uo nom  
Io1L  
Io2L  
40 IMX  
6.1  
4.6  
DUo U Line/load regulation  
Ui min...Ui max  
Io = (0.05...1) Io nom  
,
±1  
±1  
%
2
uo1/2  
Output voltage noise  
Ui min...Ui max  
Io = Io nom  
70  
40  
80  
40  
mVpp  
3
Uo L  
Output overvoltage limit. 4  
115  
130  
4000  
±250  
1
115  
130  
2700  
±250  
1
%
µF  
Co ext Admissible capacitive load  
uo d  
td  
Dynamic  
load  
Voltage deviat. Ui nom  
o nom 1/  
Io nom  
mV  
ms  
I
2
Recovery time  
regulation  
IEC/EN 61204  
aUo  
Temperature coefficient  
DUo/DTC  
Ui min...Ui max  
Io = 0.1...1 Io nom  
±0.02  
±0.02  
%/K  
Table 6b: Output data for double output power trains.  
Output  
2 × 5 V  
2 × 12 V  
min typ max  
2 × 15 V  
min typ max  
Characteristics  
Conditions  
min typ max  
Unit  
Uo1  
Uo2  
Output voltage  
Ui nom  
Io = 0.5 Io nom  
4.95  
4.94  
5.05  
5.06  
11.88  
11.86  
12.12  
12.14  
14.85  
14.82  
15.15 V DC  
15.18  
Io nom Output current  
20 IMX Ui min...Ui max  
40 IMX  
2 × 1.35  
2 × 1.4  
3.5  
2 × 0.65  
2 × 0.55  
2 × 0.60  
A
2 × 0.70  
1.8  
IoL  
Current limit 1  
20 IMX Ui nom, TC = 25°C  
1.5  
1.6  
Uo = 93% Uo nom  
40 IMX  
3.7  
2.0  
DUo U Line regulation  
DUo l Load regulation  
Ui min...Ui max, Io nom  
±1  
±3  
±1  
±3  
±1  
±3  
%
Ui nom  
Io = (0.1...1) Io nom  
2
uo1/2  
Output voltage noise  
Ui min...Ui max  
Io = Io nom  
80  
40  
120  
60  
150  
70  
mVpp  
3
Uo L  
Output overvoltage limit. 4  
Min. load 1%  
115  
130  
4000  
±250  
1
115  
130  
470  
±400  
1
115  
130  
330  
±450  
1
%
µF  
Co ext Admissible capacitive load  
uo d  
td  
Dynamic  
load  
Voltage deviat. Ui nom  
o nom 1/  
Io nom  
mV  
ms  
I
2
Recovery time  
regulation  
aUo  
Temperature coefficient  
DUo/DTC  
Ui min...Ui max  
Io = 0.1...1 Io nom  
±0.02  
±0.02  
±0.02  
%/K  
1 The current limit is primary side controlled. In the event of a sustained overload condition the thermal protection may cause the unit to  
shutdown (restart on cool-down).  
2 BW = 20 MHz  
3 Measured with a probe according to EN 61204  
4 The overvoltage protection is via a primary side second regulation loop, not tracking with Trim control.  
Edition 5/08.2001 R1  
8/18  
Board Mountable  
DC-DC Converters  
IMX 35 Series  
Thermal Considerations  
Connection in Series  
If a converter, mounted on a PCB, is located in free, quasi-  
stationary air (convection cooling) at the indicated maxi-  
mum ambient temperature TA max (see table: Temperature  
specifications) and is operated at its nominal input voltage  
and output power, the case temperature TC measured at  
the Measuring point of case temperature TC (see: Mechani-  
cal Data) will approach the indicated value TC max after the  
warm-up phase. However, the relationship between TA and  
TC depends heavily on the conditions of operation and inte-  
gration into a system. The thermal conditions are influ-  
enced by input voltage, output current, airflow, temperature  
of surrounding components and the surfaces and proper-  
ties of the printed circuit board. TA max is therefore only an  
indicative value and under practical operating conditions,  
the ambient temperature TA may be higher or lower than  
this value.  
The outputs of one or several single or double output power  
trains may be connected in series without any precautions.  
Connection in Parallel  
Several outputs of the same converter with equal output  
voltage (e.g. 5V / 5V) can be put in parallel and will share  
their output currents almost equally.  
Parallel operation of double outputs of several converters  
with the same output voltage may cause start-up problems  
at initial start-up. This is only advisable in applications where  
one converter is able to deliver the full load current as e.g.  
required in true redundant systems.  
The first outputs (5.1V or 3.3 V) of triple output units should  
not be paralleled, except in true redundant systems using  
decoupling diodes  
Output Overvoltage Protection  
Caution: The case temperature TC measured at the:  
Measuring point of case temperature TC (see: Mechani-  
cal Data) may under no circumstances exceed the  
specified maximum value. The installer must ensure that  
under all operating conditions TC remains within the lim-  
its stated in the table: Temperature specifications.  
The outputs of the converter are protected against overvolt-  
ages by a second control loop. In the event of an overvolt-  
age on one of the outputs the unit will shut down and  
attempt to restart in short intervals. The main purpose of  
this feature is to protect against possible overvoltages  
which could occur due to a failure in the feedback control  
circuit. The overvoltage protection is not designed to with-  
stand externally applied overvoltages.  
Temperature Range  
Full output power from 40...71°C. Above 71°C the output  
power derating below should be observed. The modules  
will provide the specified output power with free air convec-  
tion cooling.  
Typical Performance Curves  
General conditions:  
TA = 25°C, unless TC is specified.  
Shut down pin left open circuit.  
Trim input not connected.  
Po/Po max  
11047  
1.2  
1.0  
0.8  
0.6  
Uo [V]  
05019  
5.5  
5.0  
4.5  
4.0  
3.5  
3.0  
0.4  
0.2  
0
40  
TA [°C]  
20  
0
80  
20  
40  
60  
Fig. 8  
Maximum allowed output power versus ambient tempera-  
ture.  
0
2
3
4
5
Io [A]  
1
Fig. 9 a  
Short Circuit Behaviour  
Uo versus Io (typ) of units with Uo = 5.1 V.  
(40 IMX 35-05D12-8).  
The current limit characteristic shuts down the converter  
whenever a short circuit is applied to an output. It acts self-  
protecting and automatically recovers after removal of the  
overload condition (hiccup mode).  
Overtemperature Protection  
The converter is protected against possible overheating by  
means of an internal temperature monitoring circuit. It shuts  
down the unit above the internal temperature limit and at-  
tempts to automatically restart. This feature prevents from  
excessive internal temperature which could occur under  
heavy overload conditions.  
Edition 5/08.2001 R1  
9/18  
Board Mountable  
DC-DC Converters  
IMX 35 Series  
Uo [V]  
Uo1, Uo2 [V]  
05020  
05039  
13  
14  
13  
12  
11  
10  
12  
11  
10  
9
Uo4  
Uo1  
8
Io1  
Io1 nom  
[%]  
50  
75  
100  
125  
150  
0
25  
7
Io total [A]  
0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8  
0
Fig. 11  
Fig. 9 b  
Flexible load distribution on power train 1 of 40 IMX 35  
D12D12-8 (4 ¥ 12 V) with load variation from 0...150% of  
Po nom on output Vo1 with Vo4 loaded with 50% of Po4 nom  
U
o1/2 versus Io1/2 of double output power trains  
(i.e. 2 × 12 V). See: Block diagram 1  
.
Uo4 [V]  
13.5  
h [%]  
05164  
05153  
90  
Ui min  
13.0  
Io4 = 0.035 A  
12.5  
80  
Ui nom  
12.0  
Io4 = 0.35 A  
70  
11.5  
11.0  
0.06  
0.20  
0.30  
0.50 0.60 0.70 Io1 [A]  
0.10  
0.40  
Po  
100 Po total  
60  
[%]  
25  
50  
75  
Fig. 10  
Cross load regulation Uo4 versus Io1 (typ) for various Io4 for  
Vo1, Vo4 on power train 1. See: Block diagram double  
output types. (20 IMX 35 D12D12-8)  
Fig. 13  
Efficiency versus input voltage and load. Typical values  
20 IMX 35 D12D12-8  
05041  
Uo [%]  
h [%]  
overload short circuit condition  
05152  
90  
100  
Ui min  
Ui nom  
switch-off  
70  
80  
70  
60  
8
t [ms]  
60  
60  
Fig. 14  
Overload switch off (hiccup mode), approximate values.  
Po  
100 Po total  
[%]  
25  
50  
75  
Fig. 12  
Efficiency versus input voltage and load. Typical values  
40 IMX 35 D12D12-8  
Edition 5/08.2001 R1  
10/18  
Board Mountable  
DC-DC Converters  
IMX 35 Series  
Auxiliary Functions  
Adjustable Output Voltage  
06137  
As a standard feature, the IMX 35 offer adjustable output  
voltages in the range 80...105% of Uo nom by use of a con-  
trol pin. The Trim control is offered either on primary or sec-  
ondary side of the converter depending on type.  
Vi+  
Vo1+  
17  
4
5
>7 kΩ  
Vo1–  
Trim  
15  
Trim 1/4  
+
Vo2+  
The double output units IMX 35-05-05, IMX 35-12-12 and  
IMX 35-15-15 have a Trim input connected to pin 5. This in-  
put influences both outputs simultaneously. Both power  
trains have passive transformer feedback and the Trim in-  
put (pin 5) is referenced to the primary side. Fig. 16 shows  
the circuit topology. Adjustment of the output voltage is pos-  
sible by means of either an external resistor Rext in the  
range of 100...105% of Uo nom (table 10) or in the range of  
80...105% of Uo nom by means of an external voltage source  
(table 11).  
Control  
circuit  
Uref = 2.5 V  
13  
Uext  
Rext  
Vo2–  
Vi–  
2
11  
Fig. 16  
Output voltage control for double and quad output units by  
means of the Trim input on the primary side.  
a) Adjustment by means of an external resistor Rext  
:
The IMX 35 triple output units feature a first power train with  
magnetic feedback. The simplified circuit is shown in  
Fig. 15. The Trim1 (pin 18) is secondary referenced and in-  
fluences only the first power train. Adjustment of the output  
voltage is possible by means of an external resistor Rext  
between the Trim1 and either Vo1+ or Vo1. If the Trim1  
Adjustment of the output voltage by means of an external  
resistor Rext is possible within the range of 100...105% of  
Uo nom. Rext should be connected between the Trim pin 5  
and Vi. Connection of Rext to Vi+ may damage the con-  
verter. Table 10 indicates suitable resistor values for typi-  
cal output voltages under nominal conditions (Ui nom, Io =  
0.5 Io nom).  
input is left open-circuit, the output voltage is set to Uo1 nom  
.
Table 9 states typical values required to program the output  
Table 10: Rext1 for Uo > Uo nom  
;
approximate values (Ui nom, Io = 0.5 Io nom  
)
06136  
Uo  
[% Uo nom  
Rext  
Vi+  
Vo1+  
Trim1  
Vo1–  
4
1
2
17  
18  
]
Trim [k]  
Trim1/ 4 [k]  
Rext1  
105...108 (107 typically)  
0
0
PUL  
105  
104  
103  
102  
101  
100  
2.0  
4.2  
8.2  
16  
47  
4.3  
9.0  
18  
33  
91  
RPUL  
Rext2  
Vi–  
15  
Fig. 15  
Input undervoltage lockout adjustment (PUL) and output  
voltage adjustment by use of the Trim1 input referenced  
to the secondary side (triple output units).  
b) Adjustment by means of an external voltage source Uext  
(Fig. 16):  
For external output voltage adjustment in the range  
80...105% of Uo nom a (0...15 V) source Uext is required,  
connected to the Trim pin 5 and Vi. Table 11 below indi-  
cates typical Uo versus Uext values. Applying a control  
voltage greater 15 V will set the converter into a hiccup  
mode. Direct paralleling of the Trim pins of units of the  
same type connected in parallel is feasible. (Input resis-  
tor of the Trim input is >7 k)  
Table 9: Uo1 versus Rext for Uo1 = 80...105% Uo nom; typical  
values (Ui nom, Io1/2 = 0.5 Io1/2 nom); triple output units  
Uo nom  
[V]  
Rext1  
Rext2  
Uo1 [V]  
[k]  
Uo1 [V]  
[k]  
3.3  
2.8  
2.97  
3.135  
0.75  
1.8  
4.7  
3.3  
3.4  
3.46  
5.6  
3.3  
5.1  
5.0  
4.84  
4.59  
33  
9.1  
2.2  
5.1  
5.36  
5.25  
3
8.5  
Table 11: Uo versus Uext for Uo = 80...105% Uo nom  
;
typical values (Ui nom, Io = 0.5 Io nom  
)
Uo  
Uext  
[% Uo nom  
]
Trim [V]  
Trim1/ 4 [V]  
voltage Uo1 to approximately the values as indicated.  
105  
102  
100  
95  
85  
80  
0
1.6  
2.5  
4.25  
8.45  
10.5  
0
1.5  
2.5  
4.25  
8.25  
10.2  
The quad output units are shown in block diagram 3. All  
types with equal output voltage have the Trim function con-  
nected to pin 5 referenced to the primary side which influ-  
ences all outputs simultaneously. The schematics are  
shown in fig. 16, the values of the adjust resistor Rext in Ta-  
ble 10 and the external voltage source in Table 11.  
The quad output unit with unequal output voltages have the  
Trim1 input (pin 5) referenced to the primary side influenc-  
ing only the output of the first power train (Uo1, Uo4).  
Edition 5/08.2001 R1  
11/18  
Board Mountable  
DC-DC Converters  
IMX 35 Series  
Synchronisation (W)  
Shut Down Function  
This logic input can be used to synchronise the oscillator to  
an external frequency source. The input is edge triggered  
with TTL thresholds, and requires a source frequency of  
490...520 kHz (duty cycle 10...90%). The external source  
frequency is internally divided by 2 to define the switching  
frequency of the converter. If unused, this pin can be con-  
nected to V1(pin 2) or left open-circuit.  
The outputs of the converters may be enabled or disabled  
by means of a logic signal (TTL, CMOS, etc.) applied to the  
shut down pin. If the shut down function is not required then  
it should be left open-circuit.  
Converter operating:  
2.0...20 V  
Converter shut down: 10...0.7 V  
Programmable Input Undervoltage Lockout PUL  
Reference (Ref)  
A special feature of these units is the accurate undervoltage  
lockout function which protects the units (and the system)  
from large currents caused by operation at low voltages.  
This ensures easier start-up in distributed power systems.  
The signal output provides a stable 5 V (±0.1 V) reference  
signal on pin Ref. It is protected by a 1 kresistor. This sig-  
nal may be used also in conjunction with the Trim input pin  
5 (primary side) as a limited external voltage reference.  
Then we recommend to connect a filter capacitor (0.1 µF)  
between Ref and Vi.  
Table 7: Turn on and turn off voltage  
Type  
Trigger level  
7...8  
Hysteresis  
0.5  
Units  
V
20 IMX 35  
40 IMX 35  
14...15.5  
1  
See: Electrical input data for a description of the turn on  
turn off voltage levels of the various types.  
The under voltage lockout levels may be programmed by  
use of an external resistor to pull up the preset level as indi-  
cated in table 8. (see: Fig. 15).  
Table 8: Typical values for Rext and the respective lockout  
voltage for input voltage.  
20 IMX 35  
40 IMX 35  
RPUL [k]  
RPUL [k]  
Ui min [V]  
8  
Ui min [V]  
15.5  
22  
43  
16  
10  
0
39  
19  
13  
9.1  
10  
12  
26  
14  
28  
16  
32  
Edition 5/08.2001 R1  
12/18  
Board Mountable  
DC-DC Converters  
IMX 35 Series  
Electromagnetic Compatibility (EMC)  
which typically occur in many installations, but especially in  
battery driven mobile applications.  
A suppressor diode together with an input filter form an ef-  
fective protection against high input transient voltages  
Electromagnetic Immunity  
Table 12: Immunity type tests  
Phenomenon  
Standard 1  
Class  
Level  
Coupling  
mode 2  
Value  
applied  
Waveform  
Source  
Imped.  
Test  
procedure  
In  
oper. form.  
Per- 3  
Electrostatic  
discharge  
to case  
IEC/EN  
61000-4-2  
2
3
3
contact discharge 4000 Vp  
(R pin open)  
1/50 ns  
330 Ω  
10 positive and  
10 negative  
discharges  
yes  
B
air discharge  
(R pin open)  
8000 Vp  
Electromagnetic IEC/EN  
field  
antenna  
10 V/m  
AM 80%  
1 kHz  
261000 MHz  
yes  
A
61000-4-3  
ENV 50204  
PM, 50% duty  
cycle, 200 Hz  
resp. frequ.  
900 MHz  
Electrical fast  
transient/burst  
IEC/EN  
61000-4-4  
4
direct +i/i  
4000 Vp bursts of 5/50 ns 50 Ω  
5 kHz rep. rate  
1 min positive  
1 min negative  
transients per  
coupling mode  
yes  
yes  
B
B
transients with  
15 ms burst  
duration and a  
300 ms period  
Surge  
IEC/EN  
61000-4-5 5  
3
+i/i  
+i/i  
2000 Vp  
1.2/50 µs  
2 Ω  
5 pos. and 5 neg.  
impulses per  
coupling mode  
EN 50155  
D
G
3
1800 V  
8400 V  
10 Vrms  
5/50 µs  
0.05/01 µs  
100 Ω  
50 Ω  
triangular  
yes  
yes  
B
A
Conducted  
IEC/EN  
AM modulated  
0.15...80 MHz  
disturbancies  
61000-4-6  
(140 dBµV) 80%, 1 kHz  
150 Ω  
1 Related and previous standards are referenced in: Technical Information: Standards.  
2 i = input, o = output.  
3 A = normal operation, no deviation from specification, B = temporary deviation from specs. possibe.  
4 For 40 IMX 35 types (additional external components required). Not applicable for 20 IMX 35 types.  
5 External components required.  
Electromagnetic Emission  
[dBµV]  
90  
07020  
80  
EN 55022 A  
EN 55022 B  
70  
60  
50  
40  
30  
20  
10  
0
MHz  
Fig. 17  
Typical disturbance voltage (quasi-peak) at the input ac-  
cording to CISPR 11/EN 55011 and CISPR 22/EN 55022,  
measured at Ui nom and Io nom. Output leads 0.1 m, twisted.  
(40 IMX 35-D12D12-9)  
Edition 5/08.2001 R1  
13/18  
Board Mountable  
DC-DC Converters  
IMX 35 Series  
CISPR 22/EN 55022, Level B Radiated  
Electromagnetic emission requirements according to  
EN 55022, class B (radiated) can be achieved by adding an  
Table 13: Input filter components for EN 55022, level B,  
radiated.  
external common mode choke and (for 20 IMX 35 types) an  
additional capacitor, see: Input Data. The filter components  
Type  
Current compensated choke  
20 IMX 35  
40 IMX 35  
Murata PLH 10A 7003R6P02  
Murata PLH 10A 1112R6P02  
should be placed as close as possible to the input of the  
converter.  
07114  
18  
13  
16  
L
07120  
V+  
Vi+  
Module  
V–  
Vi–  
Ø 0.9  
Fig. 18  
Example for external circuitry to comply with CISPR22/EN  
55022, level B, radiated  
Fig. 19  
Choke dimensions  
Immunity to Environmental Conditions  
Table 14: Temperature specifications, valid for air pressure of 800...1200 hPa (800...1200 mbar)  
Temperature  
-8 3  
Characteristics  
Conditions  
Operational 2  
min  
40  
40  
55  
max  
85  
Unit  
TA  
TC  
TS  
Ambient temperature 1  
°C  
Case temperature  
Storage temperature 1  
105  
105  
Non operational  
1 MIL-STD-810D section 501.2 and 502.2  
2 See: Thermal Considerations  
3 Start up at 55°C  
Table 15: MTBF and device hours  
MTBF  
Ground Benign  
Ground Fixed  
Ground Mobile  
MTBF acc. to MIL-HDBK-217F  
40 IMX 35-05D12-8  
TC = 40°C  
TC = 40°C  
TC = 70°C  
TC = 50°C  
336'000 h  
141'000 h  
86'000 h  
110'000 h  
Table 16: Environmental testing  
Test Method  
Standard  
Test Conditions  
Status  
Ca  
Ea  
Eb  
Fc  
Damp heat  
steady state  
IEC/DIN IEC 60068-2-3  
MIL-STD-810D section 507.2 Relative humidity:  
Duration:  
Temperature:  
40 ±2 °C  
%
56 days  
Unit not  
operating  
93 +2/-3  
Shock  
(half-sinusoidal)  
IEC/EN/DIN EN 60068-2-27  
MIL-STD-810D section 516.3 Bump duration:  
Number of bumps:  
Acceleration amplitude:  
100 gn = 981 m/s2  
6 ms  
18 (3 each direction)  
Unit  
operating  
Bump  
(half-sinusoidal)  
IEC/EN/DIN EN 60068-2-29  
MIL-STD-810D section 516.3 Bump duration:  
Number of bumps:  
Acceleration amplitude:  
40 gn = 392 m/s2  
6 ms  
6000 (1000 each direction)  
Unit  
operating  
Vibration  
(sinusoidal)  
IEC/EN/DIN EN 60068-2-6  
Acceleration amplitude:  
0.35 mm (10...60 Hz)  
5 gn = 49 m/s2 (60...2000 Hz) operating  
10...2000 Hz  
Unit  
Frequency (1 Oct/min):  
Test duration:  
7.5 h (2.5 h each axis)  
Fh  
Kb  
Vibration  
broad-band  
random  
IEC/EN 60068-2-64  
MIL-STD-810D section 514.3 Frequency band:  
Acceleration magnitude:  
Acceleration spectral density: 0.05 gn2/Hz  
Unit  
operating  
20...500 Hz  
4.9 gn rms  
(digital control)  
Test duration:  
3 h (1 h each axis)  
Salt mist, cyclic  
(sodium chloride  
NaCl solution)  
IEC/EN/DIN IEC 60068-2-52  
Concentration:  
Duration:  
Storage:  
Storage duration:  
Number of cycles:  
5% (30°C)  
Unit not  
operating  
2 h per cycle  
40°C, 93% rel. humidity  
22 h per cycle  
3
Edition 5/08.2001 R1  
14/18  
Board Mountable  
DC-DC Converters  
IMX 35 Series  
Mechanical Data  
Dimensions in mm. Tolerances ±0.3 mm unless otherwise indicated.  
European  
Projection  
09121  
09123  
0.8 x 0.8  
thread M3  
0.8 x 0.8  
Tc1  
Tc  
Tc2  
63.5  
72.8  
63.5  
69.6  
76.2  
option Z  
Fig. 20  
Case IMX 35 (Standard)  
Weight: approx. 70 g  
09129  
option Y  
Fig. 21  
IMX 35 open frame (option Z) and 20 IMX 35 triple output,  
open frame with base plate (option Y)  
Edition 5/08.2001 R1  
15/18  
Board Mountable  
DC-DC Converters  
IMX 35 Series  
Safety and Installation Instructions  
Table 18: Pin allocation  
Installation Instructions  
Installation of the DC-DC converters must strictly follow the  
national safety regulations in compliance with the enclo-  
sure, mounting, creepage, clearance, casualty, markings  
and segregation requirements of the end-use application.  
Pin No.  
Double  
output  
Triple  
output  
Quad  
output  
1
2
PUL  
Vi–  
PUL  
Vi–  
PUL  
Vi–  
Connection to the system shall be made via a printed circuit  
board with hole diameters of 1.5 mm for the pins.  
3
n.c.  
n.c.  
n.c.  
4
Vi+  
Vi+  
Vi+  
The units should be connected to a secondary circuit.  
5
Trim  
W
n.c.  
Trim or Trim1/4  
W
Check for hazardous voltages before altering any connec-  
tions.  
6
W
Do not open the module.  
7
Ref  
Ref  
Ref  
Ensure that a unit failure (e.g. by an internal short-circuit)  
does not result in a hazardous condition. See also: Safety  
of operator accessible output circuit.  
8
SD or i  
Vo2–  
n.c.  
SD or i  
Vo3–  
Vo3+  
Vo2+  
Vo2–  
Vo1–  
n.c.  
SD or i  
Vo3–  
Vo3+  
Vo2+  
Vo2–  
Vo1–  
Vo1+  
Vo4+  
Vo4–  
n.c.  
11  
12  
13  
14  
15  
16  
17  
18  
19  
Input Fuse  
Vo2+  
n.c.  
To prevent excessive current flowing through the input sup-  
ply line in case of a short-circuit across the converter input  
an external fuse should be installed in a non earthed input  
supply line. We recommend a fast acting fuse F8.0A for  
20 IMX 35 types, F4.8 A for 40 IMX 35 types.  
Vo1–  
n.c.  
Vo1+  
n.c.  
Vo1+  
Trim1  
n.c.  
Standards and approvals  
All DC-DC converters are pending to be UL recognized ac-  
cording to UL 69950, UL recognized for Canada to CAN/  
CSA C22.2 No. 950-95 and IEC/EN 60950 standards.  
n.c.  
09122  
The units have been evaluated for:  
Building in  
11  
12  
13  
14  
15  
16  
17  
18  
19  
1
2
3
4
5
6
7
8
Supplementary insulation input to output, based on their  
maximum input voltage  
The use in a pollution degree 2 environment  
Connecting the input to a secondary circuit which is sub-  
ject to a maximum transient rating of 1500 V.  
Bottom  
view  
After approvals the DC-DC converters are subject to manu-  
facturing surveillance in accordance with the above men-  
tioned UL, CSA, EN and with ISO 9001 standards.  
Fig. 22  
Pin allocation  
Isolation  
The electric strength test is performed as factory test in ac-  
cordance with IEC/EN 60950 and UL 1950 and should not  
be repeated in the field. Power-One will not honour any  
guarantee claims resulting from electric strength field tests.  
Protection Degree  
The protection degree of the DC-DC converters is IP 30 (not  
for option Z).  
Table 17: Electric strength test voltages  
Cleaning Agents  
Characteristic  
Input to output  
IMX 35  
Output to  
output  
Unit  
In order to avoid possible damage, any penetration of  
cleaning fluids should be prevented, since the power sup-  
plies are not hermetically sealed.  
Electric strength  
test voltage 1 s  
1.2  
1.5  
-
0.2  
-
kVrms  
kV DC  
MΩ  
Notwithstanding this, units with opt. Z leaving the factory  
unlqacquered may be cleaned and lacquered by the cus-  
tomer.  
Insulation resistance  
at 500 V DC  
>100  
Partial discharge  
extinction voltage  
Consult factory  
-
kV  
Edition 5/08.2001 R1  
16/18  
Board Mountable  
DC-DC Converters  
IMX 35 Series  
Safety of operator accessible output circuit  
IEC/EN 60950 up to a configured output voltage (sum of  
nominal voltages if in series or +/configuration) of 42 V.  
If the output circuit of a DC-DC converter is operator acces-  
sible, it shall be an SELV circuit according to the IEC/EN  
60950 related safety standards  
However, it is the sole responsibility of the installer to en-  
sure the compliance with the relevant and applicable safety  
regulations. More information is given in: Technical Infor-  
mation: Safety.  
The following table shows some possible installation con-  
figurations, compliance with which causes the output circuit  
of the DC-DC converter to be an SELV circuit according to  
Table 19: Insulation concept leading to an SELV output circuit  
Conditions Front end  
DC-DC converter  
Result  
Supply  
voltage  
Minimum required grade  
of isolation, to be provided DC output safety status of the  
Maximum Minimum required  
Type  
Measures to achieve the Safety status of  
specified safety status of the DC-DC  
by the AC-DC front end,  
including mains supplied from the  
battery charger  
voltage  
front end output  
circuit  
the output circuit  
converter output  
circuit  
front end 1  
Mains  
250 V AC  
Basic  
60 V  
Earthed SELV circuit 2 IMX 35 Operational insulation  
(provided by the DC-DC  
SELV circuit  
converter)  
75 V  
60 V  
75 V  
Hazardous voltage  
secondary circuit  
IMX 35 Input fuse 3 output sup-  
pressor diodes 4, and  
Earthed SELV  
circuit  
2
earthed output circuit  
Double or reinforced  
SELV circuit  
IMX 35 Operational insulation  
(provided by the DC-DC  
converter)  
Double or reinforced  
insulated unearthed  
hazardous voltage  
secondary circuit 5  
IMX 35 Supplementary insulation  
based on the maximum  
rated output voltage from  
the front end (provided by  
the DC-DC converter)  
1 The front end output voltage should match the specified input voltage range of the DC-DC converter.  
2 The earth connection has to be provided by the installer according to the relevant safety standard, e.g. IEC/EN 60950.  
3 The installer shall provide an approved fuse (type with the lowest rating suitable for the application) in a non-earthed input conductor  
directly at the input of the DC-DC converter (see fig.: Schematic safety concept). For ULs purpose, the fuse needs to be UL-listed.  
See also: Input Fuse.  
4 Each suppressor diode should be dimensioned in such a way, that in the case of an insulation fault the diode is able to limit the output  
voltage to SELV (<60 V) until the input fuse blows (see fig.: Schematic safety concept).  
5 Has to be insulated from earth by at least basic insulation according to the relevant safety standard, based on the maximum output  
voltage from the front end.  
10004  
Fuse  
+
~
Mains  
Suppressor  
diode  
AC-DC  
front  
DC-DC  
con-  
Battery  
SELV  
end  
verter  
~
Earth  
connection  
Earth  
connection  
Fig. 23  
Schematic safety concept. Use fuse, suppressor diode  
and earth connection as per table: Safety concept leading  
to an SELV output circuit.  
Edition 5/08.2001 R1  
17/18  
Board Mountable  
DC-DC Converters  
IMX 35 Series  
Description of Options  
Table 20: Survey of options  
Option  
Function of option  
Base-plated open frame  
Open frame  
Types  
Y
Z
i
20 IMX 35 triple output types only  
All models except 20 IMX 35 triple output types  
-
Inhibit  
06138  
Option i  
Inhibit  
4
8
2
Vi+  
The output of the converter may be enabled or disabled by  
means of a logic signal (TTL, CMOS, etc.) applied to the  
inhibit pin. No output voltage overshoot will occur when the  
unit is turned on. If the inhibit function is not required the  
inhibit (pin 8) should be connected to Vito enable the out-  
put (active low logic, fail safe).  
i
Vi–  
Converter operating:  
Converter inhibited  
10 V...0.8 V  
Fig. 25  
If the inhibit is not used, the inhibit pin should be con-  
or inhibit pin left open circuit: 2.4 V...Ui max  
nected to Vi–  
Edition 5/08.2001 R1  
18/18  

相关型号:

20IMX35-12-12-9

35 Watt DC-DC Converters
POWER-ONE

20IMX35-12-12-9I

DC-DC Regulated Power Supply Module, 2 Output, 35W, Hybrid
BEL

20IMX35-12-12-9IZ

DC-DC Regulated Power Supply Module, 2 Output, 35W, Hybrid
BEL

20IMX35-1212-8

2-OUTPUT 35W DC-DC REG PWR SUPPLY MODULE
BEL

20IMX35-1212-8I

2-OUTPUT 35W DC-DC REG PWR SUPPLY MODULE
BEL

20IMX35-1212-9I

2-OUTPUT 35W DC-DC REG PWR SUPPLY MODULE
BEL

20IMX35-1212-9Z

2-OUTPUT 35W DC-DC REG PWR SUPPLY MODULE
BEL

20IMX35-1212-9ZI

DC-DC Regulated Power Supply Module, 2 Output, 35W, Hybrid
BEL

20IMX35-15-15-8I

DC-DC Regulated Power Supply Module, 2 Output, 35W, Hybrid
BEL

20IMX35-15-15-8IZ

DC-DC Regulated Power Supply Module, 2 Output, 35W, Hybrid
BEL

20IMX35-15-15-8Z

DC-DC Regulated Power Supply Module, 2 Output, 35W, Hybrid
BEL

20IMX35-15-15-9

35 Watt DC-DC Converters
POWER-ONE