0RQB-X0S11L [BEL]

45-58 VDC Input;
0RQB-X0S11L
型号: 0RQB-X0S11L
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

45-58 VDC Input

文件: 总19页 (文件大小:1585K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
0RQB-X0S11x is an isolated and regulated DC-DC converter that  
operates from a nominal 52 VDC source. This unit provides up to  
1000 W of output power from a nominal 52 VDC input.  
This unit is designed to be highly efficiency and low cost. Features  
include remote on/off, short circuit protection, over current protection,  
under voltage lockout, power good indication and over temperature  
protection.  
The converter is provided in an industry standard quarter brick  
package.  
45-58 VDC Input  
11.1 VDC @ 0 A Output / 10.6 VDC @ 94.3 A Output  
Isolated 1/4th Brick Converter  
Fixed Frequency (300 kHz)  
High Efficiency  
High Power Density  
Input Under Voltage Lockout  
OCP/SCP  
Output Over-voltage Protection  
Over Temperature Protection  
Remote On/Off  
Power Good Indication  
Parallel Operation with Droop  
Approved to UL/CSA/IEC60950-1, 2nd +A2 version (TBD)  
Class II, Category 2, Isolated DC/DC Converter (refer to IPC-9592B)  
Networking  
Computers and Peripherals  
Telecommunications  
2
0RQB-X0S11x  
MODEL  
NUMBER  
MODEL  
NUMBER  
OUTPUT  
VOLTAGE  
INPUT  
VOLTAGE  
MAX. OUTPUT  
CURRENT  
MAX. OUTPUT  
POWER  
TYPICAL  
EFFICIENCY  
0RQB-X0S11L  
0RQB-X0S11B  
0RQB-X0S11D  
0RQB-X0S110  
0RQB-X0S11A  
0RQB-X0S11C  
10.6 VDC  
10.6 VDC  
10.6 VDC  
45 VDC - 58 VDC  
45 VDC - 58 VDC  
45 VDC - 58 VDC  
94.3 A  
94.3 A  
94.3 A  
1000 W  
1000 W  
1000 W  
97.3%  
97.3%  
97.3%  
NOTE: Add “G” suffix at the end of the model number to indicate Tray Packaging.  
0
R
QB  
-
X0  
S
11  
x
y
RoHS  
Status  
Series  
Name  
Output  
Power  
Input  
Range  
Output  
Voltage  
Package  
Type  
Mounting Type  
Active Logic  
0 active high, Openframe  
L active low, Openframe  
Through hole  
mount  
RoHS  
6
1/4th  
Brick  
A active high, with HSK plate  
B active low , with HSK plate  
C active high, with HSK with Fins  
D active low, with HSK with Fins  
G Tray  
package  
1000 W  
45 58V  
10.6 V  
PARAMETER  
DESCRIPTION  
MIN  
-0.3  
-0.3  
1500  
-40  
-40  
-
TYP  
MAX  
80  
UNITS  
Continuous non-operating Input Voltage  
Remote On/Off  
-
-
-
-
-
-
-
V
V
18  
I/O Isolation Voltage  
Ambient Temperature  
Storage Temperature  
Altitude  
-
V
85  
C  
C  
m
%
125  
4000  
90  
Relative Humidity  
Operating, Non-Condensing  
10  
NOTE: Ratings used beyond the maximum ratings may cause a reliability degradation of the converter or may permanently damage the device.  
All specifications are typical at 25°C unless otherwise stated.  
PARAMETER  
DESCRIPTION  
MIN  
TYP  
52  
MAX  
58  
UNIT  
V
Operating Input Voltage  
Input Current (full load)  
Input Current (no load)  
45  
-
-
28  
A
-
100  
150  
mA  
Remote Off Input Current  
-
10  
50  
20  
-
mA  
mA  
mA  
mA  
A2s  
V
Input Reflected Ripple Current (rms)  
Input Reflected Ripple Current (pk-pk)  
Input Terminal Ripple Current Ic (RMS)  
I2t Inrush Current Transient  
-
Detail conditions please refer to input reflected  
ripple current section.  
-
200  
-
-
-
1000  
TBD  
45.0  
42.0  
-
-
42.0  
39.0  
-
-
UVLO Turn on Voltage Threshold  
UVLO Turn off Voltage Threshold  
OVLO Turn off Voltage Threshold  
OVLO Turn on Voltage Threshold  
43.5  
40.5  
63  
Input undervoltage lock-out(UVLO)  
Input overvoltage lock-out(OVLO)  
V
V
-
60  
-
V
CAUTION: This converter is not internally fused. An input line fuse must be used in application. Recommend a fast-acting fuse with  
maximum rating of 30 A on system board. Refer to the fuse manufactures datasheet for further information.  
tech.support@psbel.com  
3
0RQB-X0S11x  
All specifications are typical at nominal input, full load at 25°C unless otherwise stated.  
PARAMETER  
DESCRIPTION  
MIN  
11.045  
10.52  
TYP  
11.1  
10.6  
MAX  
11.155  
10.68  
UNIT  
Vin = 52 V, Io = 0 load  
Vin = 52 V, Io = 100% load  
V
V
Output Voltage Set Point  
Over all operating input voltage, resistive  
load and temperature conditions until end of  
life  
Output Voltage Range  
10.3  
-
11.4  
V
Load Regulation  
Vin = 52 V, Io = 0~100% load  
-
-
-
-
-
0.50  
0.40  
50  
0.60  
0.50  
100  
150  
20  
V
Line Regulation  
Vin = 45-58 V, Io = 100% load  
Ambient temperature = -40°C to 85°C  
V
Regulation Over Temperature  
Ripple and Noise (pk-pk)  
Ripple and Noise (rms)  
mV  
mV  
mV  
1000 uF, 50% ceramic, 50% Oscon or  
POSCAP. Measured at output pins,  
bandwidth = 20MHz.  
50  
10  
Output Ripple and Noise (pk-pk)  
under worst case  
Over all operating input voltage, load and  
ambient temperature condition  
-
-
-
150  
mV  
Vin = 45 V  
Vin = 52 V  
Vin = 58 V  
0
0
96.2  
94.3  
92.9  
116  
15  
A
A
Output Current Range  
0
A
Output DC Current Limit  
Rise time  
100  
-
108  
6
A
ms  
Defined as time between Vin reaching  
Turn-On voltage and Vout reaching 90% of  
final value  
Defined as time between Enable and Vout  
reaching 10% of final value  
-
-
23  
-
30  
5
ms  
ms  
Turn on Time  
Turn-On Overshoot  
Turn-Off Undershoot  
Overshoot at turn On  
Undershoot at turn Off  
-
-
-
-
350  
350  
mV  
mV  
Typically 50% ceramic, 50% Oscon or  
POSCAP.  
Output Capacitance  
Pre-Bias Voltage  
0
0
-
-
6250  
Vout  
uF  
V
5 V step in 1 us occurring within Vin  
Operating Range. Pout = 10%-100% Rated  
Power, Cout = Cout Max/2  
Response to Vin Step  
-
-
1.25  
V
Transient Response  
V 50%~75% of Max Load  
Settling Time  
-
-
-
-
-
350  
-
mV  
us  
Loadstep = 25% of Rated Power at 1 A/uS,  
4 uF/W of external capacitance,  
measured at output pins.  
200  
-
V 75%~50% of Max Load  
Settling Time  
350  
-
mV  
us  
200  
North America  
Asia-Pacific  
Europe, Middle East  
+1 408 785 5200  
+86 755 298 85888  
+353 61 225 977  
© 2017 Bel Power Solutions & Protection  
Rev. AD1  
4
0RQB-X0S11x  
Line regulation +/-0.2V  
Load regulation 0.5V  
11.5  
11.0  
10.5  
10.0  
9.5  
Min Load  
Max Laod  
9.0  
52  
39 40 41 42 43 44 45 46  
57 58  
Vin_min  
Vin_typ  
Vin_max  
Input Voltage(V)  
PARAMETER  
DESCRIPTION  
MIN  
TYP  
97.3  
300  
130  
-
MAX  
UNIT  
Efficiency  
Vin = 52 V, full load  
-
-
-
-
-
-
-
-
-
-
%
kHz  
Switching Frequency  
-
Over Temperature Protection  
Output Over Voltage Protection  
-
13.2  
V
0RQB-X0S110/L  
0RQB-X0S11A/B  
0RQB-X0S11C/D  
TBD  
TBD  
TBD  
TBD  
-
-
-
-
-
g
Weight  
g
g
Calculated Per Bell Core SR-332 (Vin = 52 V,  
FIT  
-
Vo=10.6V, Io=80% load Ta=40°C, 200LFM,  
FIT=109/MTBF)  
MTBF  
TBD  
Mhrs  
2.30 x 1.45 x 0.48  
58.42 x 36.83 x 12.20  
2.30 x 1.45 x 0.57  
58.42 x 36.83 x 14.48  
2.30 x 1.45 x 1.16  
58.42 x 36.83 x 29.37  
in  
mm  
in  
mm  
in  
0RQB-X0S110/L  
0RQB-X0S11A/B  
0RQB-X0S11C/D  
Dimensions (L × W × H)  
mm  
Isolation Characteristics  
Input to Output  
1500  
1500  
500  
10M  
-
-
-
-
-
-
-
V
V
Input to Case  
-
Output to Case  
-
-
V
Isolation Resistance  
Isolation Capacitance  
Ohm  
pF  
2700  
tech.support@psbel.com  
5
0RQB-X0S11x  
99.00%  
98.00%  
97.00%  
96.00%  
95.00%  
94.00%  
93.00%  
92.00%  
91.00%  
90.00%  
89.00%  
45V  
52V  
58V  
50 100 175 250 375 500 625 750 875 1000  
OUTPUT POWER(W)  
PARAMETER  
DESCRIPTION  
MIN  
-0.3  
2.4  
-0.3  
2.4  
-
TYP  
MAX  
0.8  
18  
UNIT  
V
Signal Low (Unit On)  
-
-
-
-
-
-
-
-
-
Active  
Low  
Remote On/Off pin is open,  
the module is off.  
Signal High (Unit Off)  
V
Signal Low (Unit Off)  
0.8  
18  
V
Active  
High  
Remote On/Off pin is open,  
the module is on  
Signal High (Unit On)  
V
EnablePin Open-Circuit Voltage  
EnablePin Current(into pin, ext. pull-up to 15 V)  
EnablePin Current(into pin, ext. pull-up to 10 V)  
EnablePin Current (out of pin, Unit On)  
EnablePin Current (out of pin, Unit Off)  
18  
V
-
0.5  
0.3  
200  
-
mA  
mA  
uA  
uA  
-
-
10  
North America  
Asia-Pacific  
Europe, Middle East  
+1 408 785 5200  
+86 755 298 85888  
+353 61 225 977  
© 2017 Bel Power Solutions & Protection  
Rev. AD1  
6
0RQB-X0S11x  
Recommended remote on/off circuit for active low  
Vin+  
On/off  
Vin-  
Vin+  
On/off  
Vin-  
Control with open collector/drain circuit  
Control with photocoupler circuit  
Vin+  
Vin+  
Vcc  
On/off  
Vin-  
On/off  
Vin-  
Permanently on  
Control with logic circuit  
Recommended remote on/off circuit for active high  
Vin+  
Vin+  
On/off  
Vin-  
On/off  
Vin-  
Control with open collector/drain circuit  
Control with photocoupler circuit  
Vin+  
Vin+  
Vcc  
On/off  
On/off  
Vin-  
Vin-  
Control with logic circuit  
Permanently on  
tech.support@psbel.com  
7
0RQB-X0S11x  
1. The Power Good signal is a non-latching open-collector output that is Low during normal operation and is pulled High when  
any of the following conditions occur:  
Over-Temperature  
Over-Current  
Vout is outside of the DC Output Band while Vin is within the Vin Operating Range  
Vin is within the Vin Operating Range but the unit is not operating (to determine if 1 Unit used in a parallel configuration  
is not operating)  
Vin is outside of the Vin Operating Range  
2. The Power Good signal is referenced to Vout(-).  
PARAMETER  
DESCRIPTION  
MIN  
8.6  
12.8  
42.5  
59  
-
TYP  
MAX  
9.0  
13.2  
45  
UNIT  
Output Voltage High (trigger limits)  
Output Voltage High (trigger limits)  
Input Voltage Low (trigger limits) Rising  
Input Voltage High (trigger limits) Rising  
Hysteresis  
-
-
-
-
1
-
-
-
-
V
V
PG signal indicates good when Vin is within  
operating range and indicates bad ~20ms before  
unit is shut-down due to OV  
V
62  
V
-
V
High State Voltage  
0
5.5  
10  
V
High State Leakage Current (into Pin)  
Low State Voltage  
0
µA  
V
0
0.8  
5
Low State Current (into Pin)  
0
mA  
Power Good Signal  
De-assert Response Time  
Power Good Signal  
Duration between the fault occurring and the  
Power-Good Signal de-asserting  
Duration between unit powering up with no faults  
and the Power Good Signal asserting  
Duration the Power-Good signal stays de-asserted  
if a transient fault occurs  
0
0
-
-
3
3
ms  
ms  
ms  
oC  
Assert Response Time  
Power Good Signal Duration  
200  
600  
For OT Warning, the PG signal will toggle as an  
impulse wave.  
Over Temperature Warning  
120  
OT Warning PG signal frequency  
OT Warning PG signal duty cycle  
70  
-
110  
kHZ  
%
47.5  
50  
52.5  
Testing setup:  
is  
ic  
Ls  
Vin+  
+
+
Cs  
Cin  
Vin-  
Notes and values in testing.  
Ls: Simulated Source Impedance (10uH).  
Cs: Offset possible source Impedance (100μF, ESR<0.2Ω@ 100kHz, 20C ).  
Cin: Electrolytic capacitor, should be as closed as possible to the power module to swallow ic ripple current and  
help with stability. Recommendation: 100μF, ESR<0.2Ω@ 100kHz, 20C.  
North America  
Asia-Pacific  
Europe, Middle East  
+1 408 785 5200  
+86 755 298 85888  
+353 61 225 977  
© 2017 Bel Power Solutions & Protection  
Rev. AD1  
8
0RQB-X0S11x  
Below measured waveforms are based on above simulated and recommended inductance and capacitance.  
is (input reflected ripple current), AC component  
ic (input terminal ripple current), AC component  
Test condition: 52Vdc input, 10.6Vdc/94.3A output and Ta=25 deg C, with a 1µF ceramic capacitor and a 270uF AL. cap at output.  
Note: Ripple and noise at full load, 52Vdc input, 10.6Vdc/94.3A output and Ta=25°C,and with a 1uF ceramic cap and a 1000uF cap  
(50% ceramic, 50% Oscon or POSCAP) at output. Ripple and noise at full load, 52Vdc input, 10.6Vdc/94.3A output and Ta=25°C,and  
with a 1uF ceramic cap and a 1000uF cap (50% ceramic, 50% Oscon or POSCAP) at output.  
tech.support@psbel.com  
9
0RQB-X0S11x  
To provide protection in a fault output overload condition, the module is equipped with internal current-limiting circuitry and can  
endure current limiting for a few mili-seconds. If the overcurrent condition persists beyond a few milliseconds, the module will shut  
down into hiccup mode and restart once every 250ms. The module operates normally when the output current goes into specified  
range. The typical average output current is 1.6A during hiccup.  
CH1: Output Voltage  
CH1: Output Voltage  
CH2: Output current waveform  
CH2: Output current waveform  
Expansion of on time portion of above figure  
Test condition:Vin=52V@Ta=25  
Under-voltage Lockout  
V1=40.5V  
V2=43.5V  
Voltage Falling  
Voltage Rising  
Input Voltage (V)  
V1  
V2  
North America  
+1 408 785 5200  
Asia-Pacific  
+86 755 298 85888  
Europe, Middle East  
+353 61 225 977  
© 2017 Bel Power Solutions & Protection  
Rev. AD1  
10  
0RQB-X0S11x  
Rise time  
Vout=10.6V/94.3A @Vin=52V, Ta=25Cext=0uF  
Vout=10.6V/94.3A @Vin=52V, Ta=25, Cext =6250uF  
Startup time  
Startup from Vin;  
Ch1: Vo;  
Startup from on/off;  
Ch1: Vo;  
Ch3: on/off  
Ch3: Vin  
Vout=10.6V/94.3A @Vin=52V, Ta=25Cext=0uF  
Vout=10.6V/94.3A @Vin=52V, Ta=25Cext=0uF  
tech.support@psbel.com  
11  
0RQB-X0S11x  
Shutdown  
Vout=10.6V/94.3A @Vin=52V, Ta=25Cext=0uF  
Vout=10.6V/94.3A @Vin=52V, Ta=25, Cext =6250uF  
75%-50% Load Transients at Vin=52V@Ta=25℃  
50%-75% Load Transients at Vin=52V@Ta=25℃  
Note: Transient Response at Vin=52V , di/dt=1A/μS, 1μF ceramic cap and 3300μF AL. cap at output, Ta=25C.  
North America  
Asia-Pacific  
Europe, Middle East  
+1 408 785 5200  
+86 755 298 85888  
+353 61 225 977  
© 2017 Bel Power Solutions & Protection  
Rev. AD1  
12  
0RQB-X0S11x  
Thermal Considerations  
New high power architectures require an accurate thermal design. Design engineers have to optimize the module working conditions  
and ensure reliable operation. Convection cooling is the common mode to cool down the module.  
Heat transfer is dependent on a test setup and it is important to characterize the module in an environment similar to existent  
electronic applications.  
Reported thermal data reflects real operating conditions because the values are physically measured in a wind tunnel.  
Thermal Test Setup  
A module in electronic cards is typically located in a busy area without relevant space around it. To simulate a real condition and  
avoid turbulence we add a cover with defined dimensions.  
The distance has to be 6.35mm (0.25”inch) from the top of the module and 6.35mm (0.25”inch) on the left and right side of the  
module.  
The values reflect most of the real applications and it is a common procedure in the power module market.  
Ambient temperature and airflow are measured in front of the module at the distance of 76.2 mm (3 inch).  
For 0RQB-X0S11 A/B  
tech.support@psbel.com  
13  
0RQB-X0S11x  
The OTP is achieved by temperature sensor U10 and it's in non-latch mode when OTP occurs. The protecting point will be varied a  
little under different conditions (air flow, ambient temperature, input voltage, load...). To enhance system reliability, the power  
module should always be operated below the maximum operating temperature shown as blow figures.  
Temperature reference points on top side  
Temperature reference point for 0RQB-X0S110/L  
Temperature reference point for 0RQB-X0S11A/B  
Temperature reference point for 0RQB-X0S11C/D  
North America  
Asia-Pacific  
Europe, Middle East  
+1 408 785 5200  
+86 755 298 85888  
+353 61 225 977  
© 2017 Bel Power Solutions & Protection  
Rev. AD1  
14  
0RQB-X0S11x  
Derating Curves for 0RQB-X0S110/L  
Derating Curves for 0RQB-X0S110/L  
Vin=52V, Longitudinal Orientation, airflow from Vout to Vin.  
Vin=52V, Transverse Orientation, airflow from Vout+ to Vout-.  
Derating Curves for 0RQB-X0S11A/B  
Derating Curves for 0RQB-X0S11A/B  
Vin=52V, Longitudinal Orientation, airflow from Vout to Vin.  
Vin=52V, Transverse Orientation, airflow from Vout+ to Vout-.  
Derating Curves for 0RQB-X0S11C/D  
Derating Curves for 0RQB-X0S11C/D  
Vin=52V, Longitudinal Orientation, airflow from Vout to Vin.  
Vin=52V, Transverse Orientation, airflow from Vout+ to Vout-.  
tech.support@psbel.com  
15  
0RQB-X0S11x  
PIN SIZE  
0.04”  
LENGTH  
0.180”  
0.180”  
0.180”  
0.180”  
0.180”  
0.180”  
0.180”  
0.180”  
PIN  
1
FUNCTION  
Vin (+)  
0.04”  
2
Enable  
Vin (-)  
0.04”  
3
0.062”  
0.062”  
0.04”  
4
Vout(-)  
5
Vout(-)  
6
PGOOD  
Vout(+)  
Vout(+)  
0.062”  
0.062”  
7
8
NOTES: This module is recommended and compatible with Pb-Free Wave Soldering and must be soldered using a peak solder  
temperature of no more than 260 ºC for less than 5 seconds.  
1) All Pins: Material - Copper Alloy;  
Finish Tin plated  
2) Undimensioned components are shown for visual reference only.  
3) All dimensions in inches; Tolerances: x.xx +/-0.02 in [0.51 mm].  
x.xxx +/-0.010 in [0.25 mm].  
North America  
Asia-Pacific  
Europe, Middle East  
+1 408 785 5200  
+86 755 298 85888  
+353 61 225 977  
© 2017 Bel Power Solutions & Protection  
Rev. AD1  
16  
0RQB-X0S11x  
PIN SIZE  
0.04”  
LENGTH  
0.180”  
0.180”  
0.180”  
0.180”  
0.180”  
0.180”  
0.180”  
0.180”  
PIN  
1
FUNCTION  
Vin (+)  
0.04”  
2
Enable  
Vin (-)  
0.04”  
3
0.062”  
0.062”  
0.04”  
4
Vout(-)  
5
Vout(-)  
6
PGOOD  
Vout(+)  
Vout(+)  
0.062”  
0.062”  
7
8
NOTES: This module is recommended and compatible with Pb-Free Wave Soldering and must be soldered using a peak solder  
temperature of no more than 260 ºC for less than 5 seconds.  
1) All Pins: Material - Copper Alloy;  
Finish Tin plated  
2) Undimensioned components are shown for visual reference only.  
3) All dimensions in inches; Tolerances: x.xx +/-0.02 in [0.51 mm].  
x.xxx +/-0.010 in [0.25 mm].  
tech.support@psbel.com  
17  
0RQB-X0S11x  
17.3  
PIN SIZE  
0.04”  
LENGTH  
0.180”  
0.180”  
0.180”  
0.180”  
0.180”  
0.180”  
0.180”  
0.180”  
PIN  
1
FUNCTION  
Vin (+)  
0.04”  
2
Enable  
Vin (-)  
0.04”  
3
0.062”  
0.062”  
0.04”  
4
Vout(-)  
5
Vout(-)  
6
PGOOD  
Vout(+)  
Vout(+)  
0.062”  
0.062”  
7
8
NOTES: This module is recommended and compatible with Pb-Free Wave Soldering and must be soldered using a peak solder  
temperature of no more than 260 ºC for less than 5 seconds.  
1) All Pins: Material - Copper Alloy;  
Finish Tin plated  
2) Undimensioned components are shown for visual reference only.  
3) All dimensions in inches; Tolerances: x.xx +/-0.02 in [0.51 mm].  
x.xxx +/-0.010 in [0.25 mm].  
North America  
Asia-Pacific  
Europe, Middle East  
+1 408 785 5200  
+86 755 298 85888  
+353 61 225 977  
© 2017 Bel Power Solutions & Protection  
Rev. AD1  
18  
0RQB-X0S11x  
Safety :  
EMC:  
Material flammability: UL94V-0  
Compliance to EN/IEC60950-1  
Compliance to UL/CSA60950-1  
1. Surge:  
IEC61000-4-5  
2. DC-DIP:  
3. Conductive EMI:  
IEC61000-4-29  
EN55022 class A  
Compliance to EN55022 class A (both peak and average) with the following inductive and capacitive filter  
Setup:  
ITEM  
DESIGNATOR  
CX2  
PARAMENTER  
VENDOR  
VENDOR P/N  
1
2
\
\
\
\
\
\
\
\
\
\
\
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
CX3  
3
CY31  
4
CY32  
5
CY41  
6
CY42  
7
RY31  
8
RY32  
9
RY41  
10  
11  
RY42  
T2A  
T1A,CX1,CX2,RY11,RY21,  
RY12,RY22,CY11,CY21,CY122,CY22  
12  
NIL  
-
-
tech.support@psbel.com  
19  
0RQB-X0S11x  
DATE  
REVISION  
CHANGES DETAIL  
APPROVAL  
Zhao Tang  
Zhao Tang  
Zhao Tang  
Zhao Tang  
2016-2-19  
2016-05-17  
2016-06-20  
2016-08-10  
A
B
C
D
First release  
Add PGOOD Item; Change Remote turn-on time and Mechanical Outline.  
Update Start up Figures  
Update UVLO, TD Curve and Mechanical Outline  
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,  
equipment used in hazardous environments, or nuclear control systems.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the  
date manufactured. Specifications are subject to change without notice.  
North America  
Asia-Pacific  
Europe, Middle East  
+1 408 785 5200  
+86 755 298 85888  
+353 61 225 977  
© 2017 Bel Power Solutions & Protection  
Rev. AD1  

相关型号:

0RQB-X0S11X

45-58 VDC Input
BEL

0RQB-X3S11B

Isolated DC-DC Converter
BEL

0RQB-X3S11F

Isolated DC-DC Converter
BEL

0RSB-30T025

DC-DC Regulated Power Supply Module, 1 Output, 25W, Hybrid, ROHS COMPLIANT PACKAGE-8
BEL

0RSB-30T033G

DC-DC Regulated Power Supply Module, 1 Output, 30W, Hybrid, ROHS COMPLIANT PACKAGE-8
BEL

0RSB-30T03LG

DC-DC Regulated Power Supply Module, 1 Output, 30W, Hybrid, ROHS COMPLIANT PACKAGE-8
BEL

0RSB-30T050

DC-DC Regulated Power Supply Module, 1 Output, 35W, Hybrid, ROHS COMPLIANT PACKAGE-8
BEL

0RSB-30T05L

DC-DC Regulated Power Supply Module, 1 Output, 35W, Hybrid, ROHS COMPLIANT PACKAGE-8
BEL

0RSB-30T120

DC-DC Regulated Power Supply Module, 1 Output, 36W, Hybrid, ROHS COMPLIANT PACKAGE-8
BEL

0RSB-30T12L

DC-DC Regulated Power Supply Module, 1 Output, 36W, Hybrid, ROHS COMPLIANT PACKAGE-8
BEL

0RSB-30TV20

DC-DC Regulated Power Supply Module, 1 Output, 18W, Hybrid, ROHS COMPLIANT PACKAGE-8
BEL

0RSB-30TV50

DC-DC Regulated Power Supply Module, 1 Output, 19.5W, Hybrid, ROHS COMPLIANT PACKAGE-8
BEL