0RLC-25T033G [BEL]
DC-DC Regulated Power Supply Module, 1 Output, 23W, Hybrid, ROHS COMPLIANT PACKAGE-6;型号: | 0RLC-25T033G |
厂家: | BEL FUSE INC. |
描述: | DC-DC Regulated Power Supply Module, 1 Output, 23W, Hybrid, ROHS COMPLIANT PACKAGE-6 转换器 电源电路 |
文件: | 总10页 (文件大小:298K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
ISOLATED DC/DC CONVERTERS
48 Vdc Input
3.3 Vdc - 24 Vdc/7 A - 1.25 A Output
0RLC-25T Series
RoHS Compliant
Rev.A
•
•
•
•
•
•
•
Fixed Frequency (230 kHz)
Output Over Voltage Shut Down
Isolated
•
•
•
•
•
•
Remote On/Off
Output Voltage Trim
Input Under Voltage Lockout
SCP/OCP
High Efficiency
High Power Density
Low Cost
Over Temperature Protection
Remote On/Off Logic (Option)
Safety Approval to UL60950-1
(Pending)
Description
The 0RLC-25T series are isolated dc/dc converters that operate from a nominal 48 Vdc source. These units will
provide up to 30 W of output power. These units are designed to be high efficient and very low cost. Features
include remote on/off, over current protection, and under voltage lockout. These converters are provided in an
industry standard package.
Part Selection
Output
Voltage
3.3 Vdc
Input Voltage
Max. Output
Current
7 A
Max. Output
Power
Typical
Efficiency
88%
Model Number
Active High
0RLC-25T033
0RLC-25T050
0RLC-25T120
0RLC-25T150
0RLC-25T240
Model Number
Active Low
0RLC-25T03L
0RLC-25T05L
0RLC-25T12L
0RLC-25T15L
0RLC-25T24L
36 Vdc - 75 Vdc
36 Vdc - 75 Vdc
36 Vdc - 75 Vdc
36 Vdc - 75 Vdc
36 Vdc - 75 Vdc
23 W
5.0 Vdc
12.0 Vdc
15.0 Vdc
24.0 Vdc
5 A
25 W
30 W
30 W
30 W
90%
90%
90%
91%
2.5 A
2.0 A
1.25 A
Notes: 1. Add “G” suffix at the end of the model number to indicate Tray Packaging.
2. All part numbers above indicate RoHS 6. Change the second letter "R" to "7" for RoHS 5 part numbers.
Absolute Maximum Ratings
Parameter
Input Voltage (continuous)
Remote On/Off
Min
Typ
Max
80 V
12 V
85 °C
Notes
100 V for 100 mS Max
-0.3 V
-0.3 V
-40 °C
-
-
-
Ambient Temperature
Storage Temperature
-
-55 °C
125 °C
Input Specifications
Parameter
Input Voltage
Min
36 V
Typ
-
Max
75 V
Notes
Input Current
Input Current (no load)
Remote Off Input Current
-
-
-
-
1.1 A
40 mA
10 mA
25 mA
3 mA
Input Reflected Ripple Current
(rms)
With simulated source impedance of 10
uH, 5 Hz to 20 MHz. And use a 100 uF/
100 V electrolytic capacitor with ESR=1
ohm max, at 200 kHz.
-
10 mA
20 mA
Input Reflected Ripple Current
(pk-pk)
I2t Inrush Current Transient
-
-
40 mA
60 mA
0.012 A2s
0.024 A2s
Turn-on Input Voltage
Turn-off Input Voltage
31 V
30 V
34 V
33 V
36 V
35 V
Note: All specifications are typical at 25 °C unless otherwise stated.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input
3.3 Vdc - 24 Vdc/7 A - 1.25 A Output
Output Specifications
Parameter
Min
Typ
Max
Notes
Output Voltage Set Point
VO=3.3 V
VO=5.0 V
VO=12.0 V
VO=15.0 V
VO=24.0 V
3.234 V
4.900 V
11.76 V
14.70 V
23.52 V
3.3 V
5.0 V
12.0 V
15.0 V
24.0 V
3.366 V
5.100 V
12.240 V
15.300 V
24.480 V
Test condition: Vin=48 V,
IO=50% full load at the
output.
Line Regulation
Load Regulation
VO=3.3 V
VO=5.0 V
VO=12.0 V
VO=15.0 V
VO=24.0 V
-
-
-
-
-
±1 mV
±2 mV
±5 mV
±8 mV
±10 mV
±3 mV
±5 mV
±10 mV
±15 mV
±20 mV
VO=3.3 V
VO=5.0 V
VO=12.0 V
VO=15.0 V
VO=24.0 V
-
-
-
-
-
±2 mV
±4 mV
±9 mV
±10 mV
±15 mV
±5 mV
±8 mV
±18 mV
±20 mV
±30 mV
Temperature Regulation (-40 °C to +85 °C)
VO=3.3 V
-
-
-
-
-
30 mV
40 mV
100 mV
120 mV
150 mV
50 mV
70 mV
170 mV
200 mV
240 mV
VO=5.0 V
VO=12.0 V
VO=15.0 V
VO=24.0 V
Ripple and Noise (rms)
Ripple and Noise (pk-pk)
Output Current
VO=3.3 V
VO=5.0 V
VO=12.0 V
VO=15.0 V
VO=24.0 V
-
-
-
-
-
10 mV
10 mV
10 mV
15 mV
20 mV
20 mV
20 mV
20 mV
30 mV
40 mV
Test condition of the output
ripple and noise: 0-20 MHz
BW, with a 1 µF ceramic
capacitor and a
VO=3.3 V
VO=5.0 V
VO=12.0 V
VO=15.0 V
VO=24.0 V
-
-
-
-
-
40 mV
40 mV
40 mV
80 mV
85 mV
75 mV
75 mV
75 mV
120 mV
150 mV
220 uF /35 V at the output.
VO=3.3 V
VO=5.0 V
VO=12.0 V
VO=15.0 V
VO=24.0 V
0 A
0 A
0 A
0 A
0 A
-
-
-
-
-
7.0 A
5.0 A
2.5 A
2.0 A
1.25 A
Current Limit Threshold
VO=3.3 V
VO=5.0 V
VO=12.0 V
VO=15.0 V
VO=24.0 V
7.7 A
5.5 A
3.0 A
2.2 A
1.5 A
-
-
-
-
-
12.0 A
8.0 A
4.2 A
3.4 A
2.2 A
Short Circuit Surge Transient
-
0.5 A2s
1 A2s
Turn on Time
-
-
10 mS
0%
25 mS
5%
Overshoot at Turn On
Output Capacitance
VO=3.3 V
VO=5.0 V
VO=12.0 V
VO=15.0 V
VO=24.0 V
0 uF
0 uF
0 uF
0 uF
0 uF
-
-
-
-
-
3300 uF
2200 uF
330 uF
330 uF
330 uF
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input
3.3 Vdc - 24 Vdc/7 A - 1.25 A Output
Output Specifications (continued)
Parameter
Min
Typ
Max
Notes
Transient Response
Overshoot
Settling Time
Overshoot
Settling Time
Overshoot
Settling Time
Overshoot
Settling Time
Overshoot
Settling Time
Overshoot
Settling Time
Overshoot
Settling Time
Overshoot
Settling Time
Overshoot
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
75 mV
150 uS
75 mV
100 mV
200 uS
100 mV
200 uS
150 mV
200 uS
150 mV
200 uS
200 mV
200 uS
200 mV
200 uS
200 mV
300 uS
200 mV
300 uS
300 mV
500 uS
300 mV
500 uS
50% ~ 75%
Max Load
Vo=3.3 V
Vo=5.0 V
Vo=12.0 V
Vo=15.0 V
Vo=24.0 V
25% ~ 50%
Max Load
150 uS
100 mV
150 uS
100 mV
150 uS
150 mV
150 uS
150 mV
150 uS
100 mV
200 uS
100 mV
200 uS
150 mV
300 uS
150 mV
300 uS
50% ~ 75%
Max Load
25% ~ 50%
Max Load
Test condition of the
transient response:
di/dt=0.1 A/us, Vin=48 V,
with a 220 uF/35 V
electrolytic capacitor at the
output.
50% ~ 75%
Max Load
25% ~ 50%
Max Load
50% ~ 75%
Max Load
25% ~ 50%
Max Load
50% ~ 75%
Max Load
Settling Time
Overshoot
Settling Time
25% ~ 50%
Max Load
Note: All specifications are typical at nominal input, full load at 25°C unless noted.
General Specifications
Parameter
Min
Typ
Max
Notes
Efficiency
VO=3.3 V
VO=5.0 V
VO=12.0 V
VO=15.0 V
VO=24.0 V
85%
87%
87%
87%
86%
88%
90%
90%
90%
89%
-
-
-
-
-
Measured at Vin=48 V, IO=Io, max
Switching Frequency
Output Trim Range
I/O Isolation Voltage
Isolation Capacitance
Output Voltage Trim Range
Over Temperature Protection
Over Voltage Protection
200 kHz
90% VO
1500 V
-
90%
-
230 kHz
260 kHz
110% VO
-
-
-
1500 pF
-
-
110%
-
110 °C
VO=3.3 V
3.9 V
5.7 V
13.6 V
18.0 V
28.8 V
-
-
-
-
-
5.0 V
7.0 V
14.2 V
22.5 V
36.0 V
Test condition of Over Voltage Protection:
Vin=48 V, Io=100% load at 25 °C ambient.
VO=5.0 V
VO=12.0 V
VO=15.0 V
VO=24.0 V
Calculated Per Bell Core SR-332 (IO = 80%
load; Vin=48 V; Vo=3.3 V; Ta = 25 °C)
MTBF
2,602,427 hours
Dimensions
Inches (L × W × H)
2.0 x 1.0 x 0.438
Millimeters (L × W × H)
50.8 x 25.4 x 11.14
20 g
Weight
-
-
Note: All specifications are typical at 25 °C unless otherwise stated.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input
3.3 Vdc - 24 Vdc/7 A - 1.25 A Output
Control Specifications
Parameter
Min
Typ
Max
Notes
Remote On/Off
Signal Low (Unit On)
-0.3 V
3.5 V
-
-
-
-
-
0.8 V
12 V
Active Low
Signal High (Unit Off)
Signal Low (Unit Off)
Signal High (Unit On)
Current Sink
The remote On/Off pin open,
Unit On.
-0.3 V
3.5 V
0.8 V
Active High
12 V
0.3 mA
0.75 mA
Output Trim Equations
Equations for calculating the trim resistor (in kΩ) given the desired adjusted voltage (Vadj) and the nominal
output voltage of the converter (Vnom) are shown below. The Trim Down resistor should be connected between
the Trim pin and Vout. The Trim Up resistor should be connected between the Trim pin and Ground. Only one of
the resistors should be used for any given application.
Vout
Rtrim_down
A
ModuleTrim
Rtrim_ down
=
− B
Vnom −Vadj
GND
Vout
C
ModuleTrim
Rtrim_ up
=
− D
Vadj −Vnom
Rtrim_up
GND
Vnom
24.0
15.0
12.0
5.0
A
B
C
D
272.305
92.125
53.320
19.300
21.711
15.664
9.360
9.260
15.120
40.610
31.634
18.400
14.025
6.350
3.010
2.000
3.650
10.000
30.100
3.3
13.032
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input
3.3 Vdc - 24 Vdc/7 A - 1.25 A Output
Efficiency Data
95%
90%
85%
80%
75%
70%
65%
60%
55%
50%
90%
85%
80%
75%
70%
65%
60%
55%
50%
36
48
75
36V
48V
75V
0.5A
1.25A
2.5A
3.75A
5A
0.7A
1.75A
3.5A
5.25A
7A
OUTPUT CURRENT (A)
OUTPUT CURRENT (A)
0RLC-25T033
0RLC-25T050
95%
95%
90%
85%
80%
75%
70%
65%
60%
55%
50%
90%
85%
80%
75%
70%
65%
60%
55%
50%
36
48
75
36
48
75
0.2A
0.5A
1.0A
1.5A
2.0A
0.25A
0.625A
1.25A
1.875A
2.5A
OUTPUT CURRENT (A)
OUTPUT CURRENT (A)
0RLC-25T120
0RLC-25T150
95%
90%
85%
80%
75%
70%
65%
60%
55%
50%
36
48
75
0.125A 0.3215A 0.625A 0.9375A 1.25A
OUTPUT CURRENT (A)
0RLC-25T240
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input
3.3 Vdc - 24 Vdc/7 A - 1.25 A Output
Thermal Derating Curves
0RLC-25T033
0RLC-25T050
0RLC-25T120
0RLC-25T150
0RLC-25T240
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input
3.3 Vdc - 24 Vdc/7 A - 1.25 A Output
Ripple and Noise Waveforms
Ripple and noise at full load, 3.3 Vdc/7 A output
Ripple and noise at full load, 5.0 Vdc/5 A output
Ripple and noise at full load, 12 Vdc/2.5 A output
Ripple and noise at full load, 15 Vdc/2 A output
Ripple and noise at full load, 24 Vdc/1.25 A output
Note: Ripple and noise at 48 Vdc input, with a 0.47 uF ceramic cap at the output, Ta=25 deg C.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input
3.3 Vdc - 24 Vdc/7 A - 1.25 A Output
Transient Response Waveforms
Transients 25% to 50% load 3.3 Vdc output
Transients 25% to 50% load 5.0 Vdc output
Transients 25% to 50% load 12 Vdc output
Transients 50% to 75% load 3.3 Vdc output
Transients 50% to 75% load 5.0 Vdc output
Transients 50% to 75% load 12 Vdc output
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input
3.3 Vdc - 24 Vdc/7 A - 1.25 A Output
Transient Response Waveforms (continued)
Transients 25% to 50% load 15 Vdc output
Transients 50% to 75% load 15 Vdc output
Transients 25% to 50% load 24 Vdc output
Transients 50% to 75% load 24 Vdc output
Note: Transient response at 48 Vdc input, di/dt=0.1 A/uS, with external 220 uF electrolytic cap and 0.47 uF
ceramic cap at the output, and Ta=25 deg C.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input
3.3 Vdc - 24 Vdc/7 A - 1.25 A Output
Mechanical Outline
Pin Connections
Pin
Function
1
Vin+
2
Vin-
3
CNT
Vo+
4
5
Vo-
6
Trim
RoHS Compliance
Complies with the European Directive 2002/95/EC, calling for the elimination of lead and
other hazardous substances from electronic products.
©2007 Bel Fuse Inc. Specifications subject to change without notice. 030207
CORPORATE
FAR EAST
EUROPE
Bel Fuse Inc.
Bel Fuse Ltd.
Bel Fuse Europe Ltd.
206 Van Vorst Street
Jersey City, NJ 07302
Tel 201-432-0463
Fax 201-432-9542
www.belfuse.com
8F/ 8 Luk Hop Street
San Po Kong
Kowloon, Hong Kong
Tel 852-2328-5515
Fax 852-2352-3706
www.belfuse.com
Preston Technology Management Centre
Marsh Lane, Suite G7, Preston
Lancashire, PR1 8UD, U.K.
Tel 44-1772-556601
Fax 44-1772-888366
www.belfuse.com
相关型号:
0RLC-25T05LG
DC-DC Regulated Power Supply Module, 1 Output, 25W, Hybrid, ROHS COMPLIANT PACKAGE-6
BEL
0RLC-25T120G
DC-DC Regulated Power Supply Module, 1 Output, 30W, Hybrid, ROHS COMPLIANT PACKAGE-6
BEL
0RLC-25T150G
DC-DC Regulated Power Supply Module, 1 Output, 30W, Hybrid, ROHS COMPLIANT PACKAGE-6
BEL
©2020 ICPDF网 联系我们和版权申明