Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
This product is a semi-custom AC-DC power supply with full digital control. Up to three channels of different type with
different output voltage can be selected in arbitrary combination. The PMBus communication function allows to change
the output voltage setting, overcurrent protection threshold, turn-on and turn-off sequences, switching frequency, etc., and
also to monitor the status of power supply.
■ Characteristics
・Power supply with full digital control
・The overcurrent protection threshold can be
modified
・Input voltage: AC85V to 264V
・Output current can be increased by parallel
connection (90% derating required)
・Output voltage in each of 3 channels can be
selected separately.
・Switching frequency can be modified
・Remnant life prediction function
・Remote control, changing various settings
and monitoring the status of power supply
is possible using PMBus (serial communication)
・IEC60950 compliant design
・Adjustable output voltage range: ±15%
・High efficiency: 87%
・Withstand voltage between I/O: AC 3kV
・UVLO
・Overvoltage protection, overheat protection
■ Models and ratings
Table1
Efficiency
%(typ.)
Models
Input V
Vac
Number of
Channels
Output V
Vdc
Output I
A
Output P
W
BDG Series
5 (4.25 to 5.75)
12 (10.2 to 13.8)
24 (20.4 to 27.6)
14
6
3
216 (total of 3
outputs)
BDG-200
85 to 264
3
87
Note 1: Output voltage setting range is given in brackets ( ) after the output voltage. The output voltage can be changed using PMBus.
Note 2: Each channel of a unit can be selected arbitrarily from the three channels above. Unit cannot be modified after shipment.
Note 3: The efficiency is given for output voltage Ch 1: 5V, Ch 2: 12V, Ch 3: 24V, input voltage 200V, rated output, switching frequency
260kHz and normal temperature.
Note 4: Depending on ambient temperature, temperature derating may be required.
■ Specifications
Input voltage range
Rated input voltage
Rated output voltage
Output voltage setting range
Line regulation
Table 2
Refer to Table 1.
100VAC
5V±2% (5V output), 12V±2% (12V output), 24±2% (24V output)
Refer to Table 1.
1% max. (for rated output, input voltage range given in Table 1)
2% max. (for rated input/output voltage, load varying from 0 to 100%)
2% max. (for rated input/output, operating temperature range −10°C to +50°C)
±3% max. (Including input, load and temperature regulations)
50mVp-p typ. (5V output), 100mVp-p typ. (12V output), 150mVp-p typ. (24V output)
(for rated input/output, normal temperature, measurement frequency bandwidth 20MHz)
Load regulation
Temperature regulation
Integrated regulation
Ripple noise
Efficiency
Overcurrent protection
87% typ. (for Ch 1: 5V, Ch 2: 12V, Ch 3: 24V, input voltage 200V, rated output, normal temperature)
Triggers at 110% or more of the rated load current (constant current dropping type, automatic
restoration)
Output overvoltage protection Yes (shutdown, restored when input voltage is reapplied)
Under voltage lock out
Input overcurrent protection
Overheat protection
Remote ON/OFF
Yes
Internal fuse in line and neutral (T6.3A, AC250V)
Yes (shutdown, restored when input voltage is reapplied)
Output is ON when between ON/OFF pin and SB_GND pin are open, and OFF when they are
short-circuit.
Input OK signal output
Device abnormal signal
output
When input voltage is normal: Low, when input voltage is too low or too high: open
Normal output: Low, abnormal: open
Parallel operation
Output hold time
Yes
20ms: output dip not exceeding 90% (for rated input)
Standby power supply
5V±5%、0.2A
Remote sensing
Withstand voltage
Yes
Between input and output: AC3000V during 1 minute, between input and FG: AC2500V during 1
minute,
between output and FG: AC500V during 1 minute, between outputs: AC500V during 1 minute.
Between input and output, between input and FG, between output and FG, between all outputs: not
less than 50MΩ (at DC500V)
Insulation resistance
Operating temperature range
Storage temperature range
Humidity range
Cooling conditions
Vibration
Operating temperature -10°C to +50°C (Refer to temperature derating on separate sheet)
Storage temperature −20°C to +85°C
20 to 95%R.H. (max. wet bulb temperature 35°C without condensation)
Natural air cooling, refer to temperature derating on separate sheet
5 to 10Hz total amplitude 10mm, 10 to 55Hz acceleration 2G (1 hour in each of 3 directions)
Acceleration 20G (3 times in each of 3 directions), shock time 11±5ms
850g typ.
Shock
Weight
Outer dimensions
W=195 L=100 H=47 typ. (mm) (excluding protrusions. Refer to section 6-1 for dimension details.)
* The above specifications are provided for rated values, unless otherwise specified.
1
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
1. Scope
These specifications apply to the isolated type AC/DC converter of BDG-200 series.
2. Models and ratings
Rated output
(Select any 3
outputs below)
Rated output of
the standby
Rated input
voltage
Model
Max output current
power supply
5V, 14A(70W)
12V, 6A(72W)
216W max.
(total for 3 outputs,
excluding standby power
source)
BDG-200-### *
AC 100V
5V, 0.2A
24V, 3A(72W)
Unless otherwise specified in the specifications, rated input, rated output and ambient temperature
25°C±5°C are used.
* ### indicates the output voltage of each channel.
# # #
BDG-200-
Channel 1 rated output voltage (1: 5V, 2: 12V, 3: 24V. 0: no unit)
C
h
annel 2rated utput voltag1: 2V V. o u it)
o e ( 5V, 2: 1 , 3: 24 0 n
: n
Channel 3 rated output voltage (1: 5V, 2: 12V, 3: 24V. 0: no unit)
Examples:
Channel 1: 5V, channel 2: 12V, channel 3: 24V
BDG-200-123
Channel 1: no unit, channel 2: 12V, channel 3: 12V
BDG-200-022
Also see chapter 14. Model names and configurations.
3. Environmental conditions
3-1 Temperature range
Operating temperature
Storage temperature
3-2 Humidity range
−10°C to +50°C (temperature over 40°C requires derating)
−20°C to +85°C
Operating humidity 20 to 95% R.H. (max. wet bulb temperature 35°C without condensation)
Storage humidity 20 to 95% R.H. (max. wet bulb temperature 53°C without condensation)
2
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
4. Specifications and standards
This product is RoHS compliant.
4-1 Input characteristics
Item
Specifications and standards
Conditions
Input voltage
Input frequency
Input current
AC85 to 264V (rated 100V)
AC47 to 63Hz (rated 50 / 60Hz)
2.6A typ., 2.7A max.
Ch 1: 5V, Ch 2: 12V, Ch 3: 24V,
rated input, rated output,
switching frequency 260kHz
Rated input and rated output
Output power 200W
Power factor
0.9 or higher
Inrush current
Leakage current
Input protection
20A or lower for rated input
1mA max.
Input voltage 264V, 60Hz
Internal fuse in line and neutral (T6.3A, AC250V)
4-2 Output characteristics and functions
4-2-1 Channels 1 to 3
*1, *2
Parameter
Specifications and standards
5V output 12V output 24V output
5V 12V 24V
Conditions
Rated output voltage
Output voltage tolerance ±2%
Output voltage setting
range
±15%
Configured via serial
communication.
Setting range of control target
value. The actual output voltage
depends on the output voltage
deviation setting.
Output current
Max. output power
Line regulation
Load regulation
0 to 14A
70W
0 to 6A
72W
0 to 3A
72W
1% max.
2% max.
Input voltage from 85 to 264V
For load regulation in the range 0
to 100%
Temperature regulation
Integrated regulation
2% max.
For temperature in the range -10 to
+50°C
±3% max.
Including input voltage, load
current and temperature
regulation. *3
Ripple noise
Efficiency
50mVp-p typ.,
100mVp-p typ., 150mVp-p typ., BW = 20MHz
100mVp-p max. 200mVp-p max. 300mVp-p max.
87% typ. (depends on combination)
Ch 1: 5V, Ch 2: 12V, Ch 3: 24V,
input voltage 200V, rated output,
switching frequency 260kHz
Threshold can be changed via
serial communication
Overcurrent protection
Operates at 110% or more of the rated
Fixed current drooping type, auto-recovery
3
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
Under voltage lock out
Yes
Activation voltage: 79V typ.
Deactivation voltage: 75V typ.
Yes
Input overvoltage
detection
Shutdown, restarts when input voltage is reapplied
Yes
ON/OFF
control
For each
Via serial communication
channel
For all
CN2 ON/OFF pin – SB_GND
open: ON
ON/OFF control via serial
communication is supported.
The control logic shown to the left
is used by default. The control logic
can be changed using serial
communication.
outputs
short-circuit or Low: OFF
Input OK signal output
Input voltage OK: Low
Input voltage too low or too high: Open
Output OK : Low
Device abnormal signal
output
Abnormal: Open
Output overvoltage
protection
Shutdown, restarts when input voltage is reapplied Threshold can be changed using
serial communication
Overheat protection
Parallel operation
Shutdown, restarts when input voltage is reapplied
Yes
Connect the same CS pins
N+1 parallel redundant operation
requires external OR connection
circuit
Switching frequency
setting
Yes (260kHz to 300kHz, rated 260kHz)
Configured via serial
communication
Derating may be required
depending on usage conditions
Output hold time
20ms: output dip not exceeding 90%
1.6s typ., 1.8s max.
Start-up
time
Input voltage Channels 1 to 3:
For turn-on delay 0ms,
turn-on rise 100ms
application
ON/OFF
control
Standby power:
Channels 1 to 3:
0.3s typ., 0.5s max.
0.6s typ.
Communication function Yes
PMBus Rev.1.1 compliant
Configured via serial
communication
Sequence setting
Yes
Sequence set time
tolerance
±2% max.
Yes
Operation monitoring
Monitoring via serial
communication
*1 Measured using measurement circuit in the chapter 4-6
*2 Unless otherwise mentioned, measured at rated input, rated output and ambient temperature 25°C±5°C.
*3 A design value; not confirmed for all values.
4
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
4-2-2 Standby output
Parameter
Specifications and standards
Conditions
Rated output voltage
Integrated fluctuation
5V
±5%
Including input, load and
temperature regulations
Ripple noise
50mVp-p max.
0 to 0.2A
Output current
Overcurrent protection No
Short circuit protection Yes
*1 Measured using measurement circuit in the chapter 4-6
*2 Unless otherwise specified, measured at rated input, rated output and ambient temperature 25°C±5°C.
4-3 Withstand voltage, isolation resistance
1) Withstand voltage
Between input and output:
Between input and FG:
Between output and FG:
Between outputs:
AC3000V during 1 minute
AC2500V during 1 minute
AC500V during 1 minute
AC500V during 1 minute
2) Insulation resistance
Between input and output, input and FG, output and FG: 50MΩ or higher (at DC500V)
Between outputs: 50MΩ or higher (at DC500V)
* At temperature 25°C±5°C. Humidity conditions according to JEITA RC-9131C.
4-4 Safety standards
IEC60950 compliant design
4-5 EMC standard
Conduced Emissions
Radiated Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
CISPR pub11 Group I Class A
CISPR pub11 Group I Class A
IEC61000-3-2
IEC61000-3-3
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-11
Class A
Level 4 Operation standard B
Level 4 Operation standard B
Level 2 Operation standard B
Level 4 Operation standard B
Class 4 Operation standard B
Level 3 Operation standard B
Operation standard B
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
* This product is designed according to the above standards.
5
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
4-6 Measurement circuit
+Vout
CN3-1,2
CN4
A
A
A
AC(L)
CN1
5
Vin
+Sense
W
6
CS
4
3
2
1
Load1
Load2
Load3
AC(N)
FG
NC
3
1
Sense Enable
S.GND
Ch1
Ch2
Ch3
V
V
V
−Sense
5
CN3-3,4
CN5-1,2
−Vout
+Vout
CN6
+Sense
6
CS
4
3
2
1
NC
Sense Enable
S.GND
−Sense
5
CN5-3,4
CN7-1,2
−Vout
+Vout
CN8
+Sense
BDG-200
6
CS
4
3
2
1
NC
Sense Enable
S.GND
−Sense
5
CN7-3,4
CN2
−Vout
+5VSB
3
A
Load4
V
R1: 4.7kΩ
R2: 4.7kΩ
R1 R2
SB_GND
4
AC_OK
ON/OFF
NC
1
2
5
6
7
8
AC_OK
NC
NC
Alarm
Alarm
GND
5V
SCL
9
10
11
12
13
14
Bus_GND
SDA
PMBus I/F
ADDR0
ADDR1
ADDR2
C1
C2
Oscilloscope
(r ise
measurement)
Passive probe
ipple no
C1: 47μF electrolytic capacitor
C2: 0.1μFlayeredceramiccapacitor
6
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
5. Temperature derating
Set the converter in a well-ventilated place and apply derating according to usage environment.
The derating graph below applies to a well-ventilated environment. The device in which the converter is
installed should have proper thermal design so that the internal temperature does not exceed temperature
conditions of the converter.
Natural air cooling, switching frequency 260kHz
Natural air cooling, switching frequency 300kHz
100
100
Mounting direction B
Mounting direction B
Mounting direction A
Mounting direction A
50
50
0
-10
0
-10
0
10
20
30
40
50
0
10
20
30
40
50
Ambient temperature [°C]
Ambient temperature [°C]
Mounting direction A
Mounting direction B
7
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
6. Outer dimensions and pins
6-1 Shape and dimensions
CN4
CN6
CN8
1
1
1
6
4
6
4
6
4
BDG-200-123
Input:
100-240V 2.7-1.2A
50-60Hz
Output 1: +5V
14A
Output 2: +12V 6A
Output 3: +24V 3A
1
1
1
Output 4: +5V
0.2A
1
2
13
14
Lot. **
B JAPAN
5
1
Ch 1 Ch 2 Ch 3
CN3 CN5 CN7
87
CN1 CN2
121.5
151.4
170.4
189.4
Lot indication
195
100
4-M3 for mounting (max. depth 4 mm)
Unit: mm
125
Dimensional tolerance: ±0.5
8
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
6-2 Description of pins
6-2-1 Global
1) Power supply input connector CN1 (B3P5-VH: J.S.T. MFG.Co., LTD.)
Pin
1
Name
Function
FG
Frame ground pin
3
AC(N)
AC(L)
AC power supply pin
AC power supply pin
5
2) Control connector CN2 (B14B-PHDSS: made by J.S.T. Connector)
Pin
1
Name
AC_OK
Function
Input OK output pin
2
ON/OFF
+5VSB
SB_GND
NC
Remote ON/OFF control (for all channels) input pin
Standby power output pin
3
4
GND pin for standby power output
Do not make other electrical connections.
Do not make other electrical connections.
Do not make other electrical connections.
Power failure output pin
5
6
NC
7
NC
8
Alarm
SCL
9
Serial communication clock input pin
Serial interface GND pin. Connected to SB_GND pin internally.
Serial interface data input/ output pin
Device address setting pin
10
11
12
13
14
Bus_GND
SDA
ADDR0
ADDR1
ADDR2
Device address setting pin
Device address setting pin
6-2-2 For each channel
1) Output voltage pins CN3, 5, 7 (0138-5104: DINKLE)
Pin
1
Name
Function
+Vout
+Vout
−Vout
−Vout
(+) Voltage output pin
(+) Voltage output pin
(-) voltage output pin
(-) voltage output pin
2
3
4
Applicable wire:
Wire strip length:
28 to 16AWG (18AWG recommended)
9mm min.
9
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
2) Output control connectors CN4, 6, 8 (53254-0670: Molex)
Pin
1
Name
S.GND
Function
Signal GND pin
2
Sense Enable
Remote sensing ON/OFF selection pin
Connect to S.GND when using remote sensing
Leave open when remote sensing is not used
Do not make other electrical connections.
Parallel operation input/ output pin
(-) Remote sensing pin
3
4
5
6
NC
CS
−Sense
+Sense
(+) Remote sensing pin
6-3 Lot indication
1 6
1 6
4
(
(Manufactured in April 2016)
(Manufactured in November 2016)
N
2
(
Manufacture control code (may not be indicated)
Month of manufacture (Jan to Sep=1 to 9, Oct=O, Nov=N, Dec = D)
Year of manufacture (the last 2 digits of A.D.)
7. Standard connection circuit
AC(L)
CN1
5
+Vout
CN3-1,2
CN4
+Sense
Load1
Load2
Load3
6
Vin
2
1
Ch1
−Sense
−Vout
5
AC(N)
3
CN3-3,4
FG
1
+Vout
CN5-1,2
CN6
+Sense
6
2
1
Ch2
Ch3
−Sense
−Vout
5
CN5-3,4
+Vout
CN7-1,2
CN8
+Sense
6
2
1
−Sense
−Vout
5
CN7-3,4
CN2
BDG-200
+5VSB
3
Load4
SB_GND
4
AC_OK
ON/OFF
NC
1
2
5
NC
6
NC
7
Alarm
SCL
8
9
Bus_GND
SDA
10
11
12
13
14
PMBus I/F
ADDR0
ADDR1
ADDR2
10
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
8. Functions
8-1 Digital control
The converter allows setting of output voltage, sequence and other parameters, and also reading of input
voltage, output current and other information using serial interface PMBus.
The serial interface allows setting of control target values. Since actual operation is influenced by variation
in products, actual and set values will be slightly different.
BDG-200
Control circuit
Overwrite
depending on
operation
Used when
monitoring
operating state
Used during execution
Copied on execution of the
STORE_USER_ALL command
condition
User store
memory
(non-volatile)
Operating memory
(volatile)
Status registers
Copied after power ON or at execution of
the RESTORE_USER_ALL command
Overwritten when
changing settings
Used when
reading settings
PMBus
interface
Used when reading
status register
Communication with
bus master device
PMBus
Bus master
device
Digital control conceptual diagram
11
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
8-1-1 Internal memory
The converter is equipped with volatile operating memory and non-volatile user store memory. Converter
settings are stored in the user store memory. The contents of the user store memory is copied into
operating memory when power is turned ON.
The control circuit of this converter operates using contents of the operating memory. When settings are
changed using serial communication, they are written into the operating memory. Because the operating
memory is volatile, the modified settings will be lost when power is turned OFF.
To change settings used when power is turned ON, they need to be saved in the non-volatile user store
memory by STORE_USER_ALL command after the operating memory is overwritten.
RESTORE_USER_ALL command can be used to replace the contents of the operating memory with the
data stored in the user store memory (revert to the settings when the previous STORE_USER_ALL
command was executed).
Settings made by the following commands can be stored and restored using STORE_USER_ALL and
RESTORE_USER_ALL commands.
ON_OFF_CONFIG
VOUT_COMMAND
VOUT_TRIM
FREQUENCY_SWITCH
VOUT_OV_FAULT_LIMIT
IOUT_OC_FAULT_LIMIT
TON_DELAY
TON_RISE
TOFF_DELAY
Setting items
Store settings
PMBus command
STORE_USER_ALL
Restore settings
RESTORE_USER_ALL
8-2 Output voltage setting
The converter allows setting of the output voltage using serial communication within the range ±15% of the
rated voltage. Since it is not possible to change the output voltage due to potentiometer etc., when output
voltage other than default setting is required, the output voltage setting needs to be changed via serial
communication.
Setting
items
PMBus command
Setting
range
Setting resolution
Default
setting
Rated
Output
voltage
setting
VOUT_COMMAND Rated
5V (with remote sensing):
App. 9mV
App. 8mV
App. 21mV
voltage
±15%
5V (without remote sensing):
12V (with remote sensing):
voltage
12V (without remote sensing): App. 19mV
24V (with remote sensing): App. 36mV
24V (without remote sensing): App. 37mV
12
BAD20190627_(BAD20170920 G0340E01C)
Bellnix AC-DC Power Supply
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
8-3 Output voltage trimming function
The output voltage trimming function can be used to increase or decrease the output voltage.
The set value of the output voltage trimming function can be modified using serial communication.
Setting items
PMBus command
VOUT_TRIM
Setting range
Setting resolution
Default
setting
Output voltage
trimming setting
5V: −100 to 100 mV Same as output
12V: −240 to 240 mV voltage setting
24V: −480 to 480 mV resolution
0mV
8-4 Remote sensing function
The remote sensing function can be used to obtain good load regulation characteristics on the load side.
The sensing line is a part of the feedback loop, and since it has very high sensitivity, careful attention is
required when making routing. +Sense and −Sense wires should be routed to the load as a twisted pair.
When using this function, the output voltage (voltage between +Vout and -Vout pins) will become higher
than voltage in the output voltage control point (between +Sense and -Sense pins), so make sure that the
output voltage does not exceed the allowable output voltage range. Also make sure that the output power
does not exceed the rated maximum output power.
When using this function, connect Sense Enable pin to S.GND pin. Connect Sense Enable and S. GND
pins at the base of the connector; do not extend these wires.
If this function is not used, leave +Sense, −Sense, Sense Enable and S.GND pins open.
8-5 ON/OFF control function
This function can be used to turn output voltage ON and OFF without connecting or disconnecting the input
voltage. This converter supports ON/OFF control for all output channels at the same time, as well as
individual ON/OFF control for each channel.
The ON/OFF control for all output channels at the same time can be done by two methods: using ON/OFF
pin and serial communication.
Individual ON/OFF control for each output channel can be performed only by serial communication.
It is possible to enable and disable ON/OFF control by ON/OFF pin and by serial communication separately.
ON/OFF control can be enabled and disabled by serial communication. By default, the ON/OFF control by
the ON/OFF pin is set enabled.
ON/OFF control command has a high OFF priority. When ON/OFF control by the ON/OFF pin and by serial
communication are both enabled, the output will not turn ON until both controls are set to ON.
ON/OFF control of the standby power is not supported.
8-5-1 ON/OFF control by the ON/OFF pin
All outputs can be turned ON or OFF by opening or short-circuiting between ON/OFF pin and SB_GND pin.
The ON/OFF pin is connected internally to 3.3V typ. power supply via 10kΩ resistor.
The control logic of the ON/OFF pin can be set to positive logic (output ON when open) or negative logic
(output OFF when open). The control logic of the ON/OFF pin can be set by serial communication. By
default it is set to active high.
13
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
Between ON/OFF pin and SB_GND pin
Active high
(default setting)
Output ON
Active low
Open
Output OFF
Output ON
Short-circuit (0 to 0.6V, 0.5mA max.)
Output OFF
3.3V typ.
10kΩ
ON/OFF
SB_GND
Note: Avoid chattering on the ON/OFF pin. The chattering may cause malfunction of internal circuits.
When turning the output OFF using the ON/OFF pin, it is possible to set whether to stop by applying the
turn-off sequence (whether to apply the turn-off delay or not). The stop method can be selected by serial
communication (ON_OFF_CONFIG command). By default it is set to stop without applying the turn-off
sequence.
8-5-2 ON/OFF control by serial communication
Output voltage can be turned ON and OFF by serial communication.
When turning the output OFF by serial communication, it is possible to set whether to apply the turn-off
sequence to stop or not.
The serial communication can be used to turn ON/OFF all channels simultaneously or individually each
channels.
Setting item
PMBus command
Default setting
ON/OFF control via serial OPERATION
communication
Output OFF*
ON/OFF control
configuration
ON_OFF_CONFIG
ON/OFF control by the ON/OFF pin Enabled
ON/OFF control via serial communication
DISABLED
ON/OFF pin active high
When turning output OFF by ON/OFF pin the
turn-off delay sequence is NOT USED
* When power is applied, it will be initialize to output OFF, which is the default setting. This setting cannot
be stored in the user store memory.
14
BAD20190627_(BAD20170920 G0340E01C)
Bellnix AC-DC Power Supply
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
8-6 Sequence setting function
The following items can be set by the sequence setting function.
Turn-on Delay
Turn-on Rise
Turn-off Delay
The turn-on delay is the time from when the ON command is issued by ON/OFF control (ON/OFF pin or
serial communication) until the output voltage starts to rise (see figure below).
The turn-off delay is the time from when the OFF command is issued by ON/OFF control (ON/OFF pin or
serial communication) until the output voltage starts to fall (see figure below).
ON
ON/OFF
Control
signal
OFF
Output
voltage 0V
Turn-on
delay
Turn-off
delay
Turn-on rise
When input voltage is applied, there is a waiting time of 1s typ. until the start of turn-on sequence (see
figure below).
Input
voltage
0V
ON/OFF
ON
Control
signal
OFF
Output
voltage
0V
Turn-on
delay
1s typ.
The setting of the sequence function can be modified using serial communication.
However, depending on the load capacitance, the charging time may be insufficient, and it may not start up
within the set time. If the charging time is insufficient, the overcurrent protection may operate.
Also, during parallel operation, the rise may be stepwise and may not rise completely within the set time.
15
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
Setting items
PMBus command
Setting range
Setting
Default
resolution
setting
Turn-on delay
TON_DELAY
0 to 5000ms 1ms
5 to 1000ms 1ms
0ms
Turn-on rise
TON_RISE
100ms
0ms
Turn-off delay
TOFF_DELAY
0 to 500ms
1ms
When all output channels are turned ON at the same time by ON/OFF pin or via serial communication,
there will be an additional delay of 500ms in actual operation, even if the turn-on delay setting is less than
500ms.
When turning ON all output channels at the same time by applying input voltage, there is a waiting time of
1s typ. before the turn-on delay (see previous page). Even if the turn-on delay setting is less than 500ms,
there will be an additional delay of 500ms in actual operation.
When all output channels are turned OFF at the same time by ON/OFF pin or via serial communication,
there will be an additional delay of 20ms in actual operation, even if the turn-off delay setting is less than
20ms.
When output channels are turned ON/OFF individually via serial communication, there will be an additional
delay of 1ms in actual operation, even if the turn-on or turn-off delay setting is less than 1ms.
The turn-off delay setting is not applied in the following cases.
When turning output OFF via serial communication with turn-off sequence disabled
When turning output OFF by ON/OFF pin with sequence disabled for the ON/OFF pin control
When output is turned off by the protection function operation
8-7 Operation monitoring
Information about input voltage, output voltage, output current, device temperature, total operating time and
estimated lifetime of the converter can be obtained via serial communication.
The converter contains 8 following status registers: STATUS_BYTE, STATUS_WORD, STATUS_VOUT,
STATUS_IOUT, STATUS_INPUT, STATUS_TEMPERATURE, STATUS_CML and
STATUS_MFR_SPECIFIC. By checking contents of status registers, it is possible to determine the error
status of this product.
The status registers are set when protection function operates, and contents of the registers are retained
even if the cause of the register setting is removed. However, the status of under voltage lock out is cleared
automatically. The status registers can be cleared under any of the following conditions.
Executing CLEAR_FAULTS command
Reapplying input voltage
Bits of the status register linked to the protection function that latch stops are not cleared even if the
CLEAR_FAULTS command is executed.
When reapplying the input voltage, keep input in OFF state for more than 30 seconds.
The contents of each register can be read via serial communication. For detailed information about
contents of each register, refer to sections describing registers reading instructions.
16
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
Item
Input voltage monitoring
Output voltage monitoring
Output current monitoring
Device temperature monitoring
Total operating time
PMBus command
READ_VIN
READ_VOUT
READ_IOUT
READ_TEMPERATURE_1, READ_TEMPERATURE_2
READ_OPERATING_TIME
READ_ESTIMATED_LIFE
STATUS_BYTE
Estimated life
STATUS_BYTE register
STATUS_WORD register
STATUS_VOUT register
STATUS_IOUT register
STATUS_INPUT register
STATUS_TEMPERATURE register
STATUS_CML register
STATUS_WORD
STATUS_VOUT
STATUS_IOUT
STATUS_INPUT
STATUS_TEMPERATURE
STATUS_CML
STATUS_MFR_SPECIFIC register
STATUS_MFR_SPECIFIC
8-8 Status register history function
This converter can save values of the status registers in nonvolatile memory when the under voltage lock
out function is operating. The saved data can be read via serial communication.
Item
PMBus command
STATUS_BYTE_HISTORY
STATUS_BYTE register history
STATUS_WORD register history
STATUS_VOUT register history
STATUS_IOUT register history
STATUS_INPUT register history
STATUS_TEMPERATURE register history
STATUS_CML register history
STATUS_MFR_SPECIFIC register history
STATUS_WORD_HISTORY
STATUS_VOUT_HISTORY
STATUS_IOUT_HISTORY
STATUS_INPUT_HISTORY
STATUS_TEMPERATURE_HISTORY
STATUS_CML_HISTORY
STATUS_MFR_SPECIFIC_HISTORY
Since the status register history is saved when the under voltage lock out function is operating, the bit
indicating the under voltage condition is always set.
Since the status register history is overwritten each time the under voltage lock out function operates, it is
not possible to obtain register values other than those that were in the status register at the time of the
latest operation of the under voltage lock out function.
8-9 Under voltage lock out
The converter is equipped with under voltage lock out (UVLO) function preventing malfunction when input
voltage is low. When the input voltage exceeds the activation voltage (79V typ.), the converter starts
switching operation. If the input voltage falls below the deactivation voltage (75V typ.), the switching
operation stops.
17
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
8-10 Input overvoltage detection
When the input voltage exceeds the threshold of the input overvoltage protection function, the converter
stops switching operation. Because internal parts are not protected, they can be damaged by excessive
input voltage.
Since this function is a latch-type function, it does not restart automatically. To release the latched condition,
reapply the input voltage. When reapplying the input voltage, keep input in OFF state for more than 30
seconds.
8-11 Output overvoltage protection
When the output voltage (the voltage between +Vout and -Vout pins) exceeds the threshold of the output
overvoltage protection function, the converter stops switching operation. However, the function may not
activate if overvoltage is caused by damaged unit.
When the remote sensing function is enabled, the voltage at output voltage control point (between +Sense
and −Sense pins) and overvoltage detection point (between +Vout and −Vout pins) will be different. So be
sure to consider voltage drop caused by wiring, when setting the protection threshold.
Since this function is a latch-type function, it does not restart automatically. To release the latched condition,
reapply the input voltage. When reapplying the input voltage, keep input in OFF state for more than 30
seconds.
The operation threshold of the output overvoltage function can be configured via serial communication.
Setting items
PMBus
Setting range
Setting resolution
Default
setting
command
Output
VOUT_OV_FA 5V: 0 to 6.75V
5V (with remote sensing):
App. 7 mV
App. 8mV
App. 18 mV
5V: 6.75V
12V: 16.2V
24V: 32.4V
overvoltage
protection
threshold
ULT_LIMIT
12V: 0 to 16.2V
24V: 0 to 32.4V
5V (without remote sensing):
12V (with remote sensing):
12V (without remote sensing): App. 20 mV
24V (with remote sensing): App. 33mV
23V (without remote sensing): App. 34 mV
8-12 Output overcurrent protection
When the output overcurrent protection function operates, the output voltage is decreased to limit the
output current. When the overcurrent condition is canceled, the output voltage will recover automatically.
The operation threshold of the output overcurrent function can be configured via serial communication.
Setting items
PMBus command
Setting range
Setting resolution
Default
setting
Output overcurrent
protection threshold
IOUT_OC_FAULT_LIMIT
5V: 7 to 16.1A
12V: 3 to 6.9A
24V: 1.5 to 3.7A
5V: App. 26mA
12V: App. 12 mA
24V: App. 6 mA
5V: 16.1A
12V: 6.9A
24V: 3.7A
18
BAD20190627_(BAD20170920 G0340E01C)
Bellnix AC-DC Power Supply
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
8-13 Overheat protection
When measured temperature of the converter exceeds the overheat protection threshold, the overheat
protection function operates, stopping the switching operation.
Since this function is a latch-type function, it does not restart automatically. To release the latched condition,
reapply the input voltage. When reapplying the input voltage, keep input in OFF state for more than 30
seconds.
There is one temperature sensor mounted on the primary side (place shown in the figure below), and there
is also one sensor for each output channel.
The temperature at which the overheat protection function triggers is not the maximum operating
temperature. Therefore, even if this temperature is below the overhead protection threshold, do not use the
converter at temperatures outside the derating range shown in chapter 5.
BDG-200-123
Input:
100-240V 2.7-1.2A
50-60Hz
Output 1: +5V
14A
Output 2: +12V 6A
Output 3: +24V 3A
Output 4: +5V
0.2A
Lot.
B
JAPAN
105.5
Primary temperature measuring point (back
side of the board)
8-14 Parallel operation
Parallel operation can be performed by connecting the +Vout pins and –Vout pins of each channel to each
other, and then connecting the CS pins to each other. Always use the remote sensing function during
parallel operation.
Set the same output voltage settings for all output channels used in parallel.
The wiring of +Vout and –Vout pins should have the same length for all output channels.
Load derating is required during parallel operation. Load factor should not exceed 90%.
Connection example
AC(L)
+Vout
CN1
5
CN3-1,2
CN4
+Sense
Load
6
4
2
1
Vin
CS
−Sense
−Vout
5
AC(N)
FG
CN3-3,4
3
1
+Vout
CN5-1,2
CN6
+Sense
6
4
2
1
CS
−Sense
−Vout
BDG-200
5
CN5-3,4
+Vout
CN7-1,2
CN8
+Sense
6
4
2
1
CS
−Sense
−Vout
5
CN7-3,4
19
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
8-15 Switching frequency setting
Using this function, the switching frequency can be set in the range from 260 kHz to 300 kHz.
The switching frequency can be set using serial communication. Settings can be changed only when all
output channels are OFF.
Setting items
PMBus command
Setting range
Setting
Default
setting
resolution
Switching frequency
FREQUENCY_SWITCH
260 to 300kHz 1kHz
260kHz
8-16 Input OK signal (AC_OK) output
The Input OK signal output can be used to notify the state of input voltage.
When the input voltage exceeds the operation start voltage, this output is in Low state. When the input
voltage falls below the operation stop voltage, this output is open (high impedance).
It also becomes open (high impedance) when input overvoltage detection function operates. After the input
overvoltage detection function is triggered, this output remains open even if the input voltage is reduced
below the threshold.
Applicable voltage:
Output Low level:
30V max.
0.4V max. (sink current 20mA max.)
8-17 Device abnormal signal (Alarm) output
The Device abnormal signal output can be used to notify if there are any device failures. The device
abnormal signal is synchronized with status registers.
Normally Low, when at least one bit of the status register is set, this output becomes open (high
impedance).
Applicable voltage:
Output Low level:
30V max.
0.4V max. (sink current 20mA max.)
9. Serial interface
9-1 Definitions of symbols and terms
9. The symbols and terms used in this chapter are defined as follows.
Symbols and terms
Byte
Definition
8 bits
Word
Set
16 bits (2 bytes)
Set bit to logic ’1’
Clear
nnb
Set bit to logic ’0’
Number ’nn’ as a binary number.
Number ’nn’ as a hexadecimal number.
nnh
20
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
9-2 Communication method
The serial interface of this converter complies with PMBus Specification Revision 1.1. For detailed
information about command transfer, etc., refer to PMBus specification (PMBus Power System
Management Protocol Specification Part I, General Requirements, Transport And Electrical Interface –
Revision 1.1 and PMBus Power System Management Protocol Specification Part II, Command Language –
Revision 1.1).
9-3 Communication pins
Connect PMBus communication pins (SDA, SCL) to a 2.7V to 5.5V power supply through a pull-up resistor
or by a similar circuit. When serial communication is not used, leave PMBus communication pins open.
2.7 to 5.5V
PMBus Master
Device
Other PMBus
Device
BDG-200
SDA
SCL
GND
GND pin of PMBus interface (Bus_GND) is internally connected to the GND pin of standby output
(SB_GND). Therefore, if ground may be unstable, for example, due to pulse load connected to the standby
output, the stability of communication may be affected.
9-3-1 SDA pin
The SDA pin is used for data input and output in the serial communication. When used as output, the pin is
configured as an open drain output.
Input Low level:
Input High Level:
Output Low level:
0 to 0.8V
2.1V min.
0.4V max. (sink current 5mA max.)
9-3-2 SCL pin
The SCL pin is used for clock input in the serial communication.
The SCL pin is not driven by the converter. The SCL pin is driven by the bus master device.
Input Low level:
Input High level:
0 to 0.8V
2.1V min.
21
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
9-4 Device address setting
Since in the PMBus interface multiple devices share the same bus, each device can be identified by its own
device address. The device address should be unique on the same bus.
The device address can be set by connecting or leaving opened between ADDR0, ADDR1, ADDR2 and
SB_GND pins. The correspondence between state of ADDR0, ADDR1 and ADDR2 pins and device
addresses are shown in the list below. Device address is set according to the status of ADDR0, ADDR1 and
ADDR2 pins at power on. Even though the status of ADDR0, ADDR1 and ADDR2 pins change after power
on, the device address will not change.
Device address
1011 000
1011 001
1011 010
1011 011
1011 100
1011 101
1011 110
1011 111
ADDR2 – SB_GND
Short circuit
Short circuit
Short circuit
Short circuit
Open
ADDR1 – SB_GND
Short circuit
Short circuit
Open
ADDR0 – SB_GND
Short circuit
Open
Short circuit
Open
Open
Short circuit
Short circuit
Open
Short circuit
Open
Open
Open
Short circuit
Open
Open
Open
9-5 Data format
9-5-1 DIRECT Data Format
The data format consists from the following elements.
X: Actual value
Y: A value read or written in Data Byte of a PMBus command (2-byte signed integer represented
as 2's complement)
m: Slope coefficient
b: Offset value
R: Exponent
*
For m, b, R values refer to descriptions of correspondent PMBus commands.
The relationship between elements is shown by the following formula.
1
X =
(Y × 10−R – b)
m
Y = (m X + b) × 10R
22
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
9-6 PMBus command
9-6-1 The list of PMBus commands
The converter supports the PMBus commands shown in the following table.
PMBus command
Command Transaction Data size
Data
Default setting
code
00h
type
(Byte)
format
PAGE
R/W Byte
R/W Byte
R/W Byte
Send Byte
Send Byte
Send Byte
R/W Word
1
1
1
0
0
0
2
―
―
―
―
―
―
00h
OPERATION
01h
02h
03h
15h
16h
21h
00h
17h
ON_OFF_CONFIG
CLEAR_FAULTS
STORE_USER_ALL
RESTORE_USER_ALL
VOUT_COMMAND
―
―
―
DIRECT 5V: 1388h (5V)
12V: 2EE0h (12V)
24V: 5DC0h (24V)
VOUT_TRIM
22h
33h
40h
R/W Word
R/W Word
R/W Word
2
2
2
DIRECT 0000h (0V)
DIRECT 0104h (260kHz)
DIRECT 5V: 1A5Eh (6.75V)
12V: 3F48h (16.2V)
FREQUENCY_SWITCH ※
VOUT_OV_FAULT_LIMIT
24V: 7E90h (32.4V)
IOUT_OC_FAULT_LIMIT
46h
R/W Word
2
DIRECT 5V: 3EE4h (16.1A)
12V: 1AF4h (6.9A)
24V: 0E74h (3.7A)
TON_DELAY
60h
61h
64h
78h
79h
7Ah
7Bh
7Ch
7Dh
7Eh
80h
88h
8Bh
8Ch
8Dh
8Eh
D0h
D1h
D8h
D9h
DAh
DBh
DCh
R/W Word
R/W Word
R/W Word
Read Byte
Read Word
Read Byte
Read Byte
Read Byte
Read Byte
Read Byte
Read Byte
Read Word
Read Word
Read Word
Read Word
Read Word
Read Word
Read Word
Read Byte
Read Word
Read Byte
Read Byte
Read Byte
2
2
2
1
2
1
1
1
1
1
1
2
2
2
2
2
2
2
1
2
1
1
1
DIRECT 0000h (0ms)
DIRECT 0064h (100ms)
DIRECT 0000h (0ms)
TON_RISE
TOFF_DELAY
STATUS_BYTE
―
―
―
―
―
―
―
―
―
―
―
―
―
―
―
―
―
―
―
―
―
―
STATUS_WORD
STATUS_VOUT
―
STATUS_IOUT
―
STATUS_INPUT
―
STATUS_TEMPERATURE
STATUS_CML
―
―
STATUS_MFR_SPECIFIC
READ_VIN
―
DIRECT
DIRECT
DIRECT
DIRECT
DIRECT
DIRECT
DIRECT
―
READ_VOUT
READ_IOUT
READ_TEMPERATURE_1
READ_TEMPERATURE_2
READ_OPERATING_TIME
READ_ESTIMATED_LIFE
STATUS_BYTE_HISTORY
STATUS_WORD_HISTORY
STATUS_VOUT_HISTORY
STATUS_IOUT_HISTORY
STATUS_INPUT_HISTORY
―
―
―
―
23
BAD20190627_(BAD20170920 G0340E01C)
Bellnix AC-DC Power Supply
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
STATUS_TEMPERATURE_HISTORY DDh
STATUS_CML_HISTORY DEh
STATUS_MFR_SPECIFIC_HISTORY E0h
Read Byte
Read Byte
Read Byte
1
1
1
―
―
―
―
―
―
* Settings can be changed only when all output channels are OFF.
The meaning of the Transaction type column from the previous table is shown below.
Transaction type Communication Bus protocols
Send Byte
Send Byte Protocol
Read Byte Protocol
Read Word Protocol
Read Byte
Read Word
R/W Byte
R/W Word
Read Byte Protocol and Write Byte Protocol
Read Word Protocol and Write Word Protocol
9-6-2 PAGE command (00h)
This command is used to select the output channel for control.
Data size: 1 byte.
Data byte
00h
Control channel
Ch1 output
Ch2 output
Ch3 output
01h
02h
03h
Primary side (STATUS_TEMPERATURE only. Not used in other commands.)
Not used
04h to FEh
FFh
All channels (OPERATION only. Not used in other commands.)
The setting made by the PAGE command affects the following commands. Commands other than below
are not affected by the setting made by the PAGE command.
OPERATION
VOUT_COMMAND
VOUT_TRIM
VOUT_OV_FAULT_LIMIT
IOUT_OC_FAULT_LIMIT
TON_DELAY
TON_RISE
TOFF_DELAY
STATUS_VOUT
STATUS_IOUT
STATUS_TEMPERATURE
READ_VOUT
READ_IOUT
READ_TEMPERATURE_2
STATUS_VOUT_HISTORY
STATUS_IOUT_HISTORY
STATUS_TEMPERATURE_HISTORY
24
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
9-6-3 OPERATION command (01h)
This command is used for ON/OFF control.
Data size: 1 byte. Function of each bit is shown in the following table.
Bit
Output
Default
setting
ON/OFF
7 – 6 5 – 4 3 – 2 1 – 0
00
01
10
XX
XX
00
XX
XX
XX
XX
XX
XX
OFF
OFF
ON
Turn-off sequence disabled
Stop output without using the sequence
specified by TOFF_DELAY command
Turn-off sequence enabled
Stop output using the sequence specified by
TOFF_DELAY command
●
—
Bits marked by X can have either 0 or 1 value; they do not affect the operation.
If a combination of values not shown above is set, the behavior is undefined.
The read/write target is set by the PAGE command. PAGE 00h to 02h sets the output channel 1 to 3, PAGE
FFh sets all output channels. For example, when turning ON the output channel 1, the output will not turn
ON unless PAGE 00h is set to ON and PAGE FFh is set to ON (the order of setting is irrelevant).
When ON / OFF control by serial communication is disabled using the ON_OFF_CONFIG command (bit 4
or bit 3 cleared), ON / OFF control cannot be performed using this command.
25
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
9-6-4 ON_OFF_CONFIG command (02h)
This command is used to set the ON/OFF control operation.
Data size: 1 byte. Function of each bit is shown in the following table.
Bit
Purpose
Value
Description
Default
setting
7–5 Reserved
Ignored Not used
4
ON/OFF control enable /
0
Disable ON / OFF control by ON / OFF pin and
serial communication
disable
1
Enable ON / OFF control by ON / OFF pin and
serial communication *
●
●
3
2
Enable / disable
0
1
Disable ON/OFF control by serial communication
Enable ON/OFF control by serial communication
ON/OFF control by serial
communication
Enable / disable
0
1
Disable ON/OFF control by ON/OFF pin
Enable ON/OFF control by ON/OFF pin
ON/OFF control by
ON/OFF pin
●
●
●
1
0
Select control logic for
ON/OFF pin
0
1
0
Negative logic (ON when short circuit)
Positive logic (ON when open)
Enable / disable turn-off
sequence when turned
OFF by ON/OFF pin
Stop output using the sequence specified by
TOFF_DELAY command
1
Stop output without using the sequence specified
by TOFF_DELAY command
*Follow the setting of bits 3-0.
When ON / OFF control by the ON / OFF pin and by serial communication are both enabled (bits 4-2 are all
set), the output will not turn ON until both controls are set to ON.
9-6-5 CLEAR_FAULTS command (03h)
This command is used to clear the status register.
Bits of the status register linked to the protection function that latches the stop state are not cleared by the
CLEAR_FAULTS instruction.
This command only clears the status register, and it does not release the latch stop state set by the
protection.
9-6-6 STORE_USER_ALL command (15h)
This command stores the contents of operating memory in nonvolatile user store memory.
Note: Always maintain the input voltage for 1 second after execution of this command. Otherwise the
contents of the user store memory may be destroyed, making its recovery impossible.
9-6-7 RESTORE_USER_ALL command (16h)
This command overwrites the contents of operating memory with the data stored in the nonvolatile user
store memory.
26
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
9-6-8 VOUT_COMMAND command (21h)
This command is used to set the output voltage.
Data size: 2 bytes, DIRECT Format is used (units: V). Coefficients: m = 1, b = 0, R = 3.
The target output channel for read/write operation is set by the PAGE command.
9-6-9 VOUT_TRIM command (22h)
This command is used to set output voltage trimming.
Data size: 2 bytes, DIRECT Format is used (units: V). Coefficients: m = 1, b = 0, R = 3.
The target output channel for read/write operation is set by the PAGE command.
9-6-10 FREQUENCY_SWITCH command (33h)
This command is used to set the switching frequency.
Data size: 2 bytes, DIRECT Format is used (units: kHz). Coefficients: m = 1, b = 0, R = 0.
9-6-11 VOUT_OV_FAULT_LIMIT command (40h)
This command is used to set the output overvoltage protection threshold.
Data size: 2 bytes, DIRECT Format is used (units: V). Coefficients: m = 1, b = 0, R = 3.
The target output channel for read/write operation is set by the PAGE command.
9-6-12 IOUT_OC_FAULT_LIMIT command (46h)
This command is used to set the output overcurrent protection threshold.
Data size: 2 bytes, DIRECT Format is used (units: A). Coefficients: m = 1, b = 0, R = 3.
The target output channel for read/write operation is set by the PAGE command.
9-6-13 TON_DELAY command (60h)
This command is used to set the Turn-on Delay parameter.
Data size: 2 bytes, DIRECT Format is used (units: ms). Coefficients: m = 1, b = 0, R = 0.
The target output channel for read/write operation is set by the PAGE command.
9-6-14 TON_RISE command (61h)
This command is used to set the Turn-on Rise parameter.
Data size: 2 bytes, DIRECT Format is used (units: ms). Coefficients: m = 1, b = 0, R = 0.
The target output channel for read/write operation is set by the PAGE command.
9-6-15 TOFF_DELAY command (64h)
This command is used to set the Turn-off Delay parameter.
Data size: 2 bytes, DIRECT Format is used (units: ms). Coefficients: m = 1, b = 0, R = 0.
The target output channel for read/write operation is set by the PAGE command.
27
BAD20190627_(BAD20170920 G0340E01C)
Bellnix AC-DC Power Supply
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
9-6-16 STATUS_BYTE command (78h)
This command is used to read the STATUS_BYTE register.
The STATUS_BYTE is a 1 byte register. Function of each bit is shown in the following table.
Bit
7
Bit name
BUSY
Description
0 at all times
0 at all times
6
OFF
5
VOUT_OV
IOUT_OC
VIN_UV
Set when overvoltage protection activates for one or more channels
Set when overcurrent protection activates for one or more channels
Set when undervoltage lock out function activates
Set when overheat protection activates
4
3
2
TEMPERATURE
CML
1
Set when one or more bits of the STATUS_CML register are set
Set when input overvoltage protection activates, or
when one or more bits of the STATUS_MFR_SPECIFIC register are
set.
0
NONE OF
ABOVE
9-6-17 STATUS_WORD command (79h)
This command is used to read the STATUS_WORD register.
The STATUS_WORD is a 2 byte register. Function of each bit is shown in the following table.
Bit
7
Bit name
BUSY
Description
0 at all times
0 at all times
6
OFF
5
VOUT_OV
IOUT_OC
VIN_UV
Set when overvoltage protection activates for one or more channels
Set when overcurrent protection activates for one or more channels
Set when undervoltage lock out function activates
4
3
2
TEMPERATURE
CML
Set when overheat protection activates
1
Set when one or more bits of the STATUS_CML register are set
0
NONE
OF Set when input overvoltage protection activates, or
when one or more bits of the STATUS_MFR_SPECIFIC register are
set.
ABOVE
7
6
VOUT
IOUT
Set when one or more bits of the STATUS_VOUT register for one or
more channels are set
Set when one or more bits of the STATUS_IOUT register for one or
more channels are set
5
4
INPUT
MFR
Set when one or more bits of the STATUS_INPUT register are set
Set when one or more bits of the STATUS_MFR_SPECIFIC register
are set
3
2
1
0
POWER_GOOD# 0 at all times
FANS
0 at all times
0 at all times
0 at all times
OTHER
UNKNOWN
28
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
9-6-18 STATUS_VOUT command (7Ah)
This command is used to read the STATUS_VOUT register.
The STATUS_VOUT is a 1 byte register. Function of each bit is shown in the following table.
Bit
7
Description
Set when output overvoltage protection triggers
6
0 at all times
0 at all times
0 at all times
0 at all times
0 at all times
0 at all times
0 at all times
5
4
3
2
1
0
The target output channel for read operation is set by the PAGE command.
9-6-19 STATUS_IOUT command (7Bh)
This command is used to read the STATUS_IOUT register.
The STATUS_IOUT is a 1 byte register. Function of each bit is shown in the following table.
Bit
7
Description
Set when output overcurrent protection activates
6
0 at all times
0 at all times
0 at all times
0 at all times
0 at all times
0 at all times
0 at all times
5
4
3
2
1
0
The target output channel for read operation is set by the PAGE command.
9-6-20 STATUS_INPUT command (7Ch)
This command is used to read the STATUS_INPUT register.
The STATUS_INPUT is a 1 byte register. Function of each bit is shown in the following table.
Bit
7
Description
Set when input overvoltage detection activates
6
0 at all times
5
0 at all times
4
Set when undervoltage lock out function activates
3
0 at all times
0 at all times
0 at all times
0 at all times
2
1
0
29
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
9-6-21 STATUS_TEMPERATURE command (7Dh)
This command is used to read the STATUS_TEMPERATURE register.
The STATUS_TEMPERATURE is a 1 byte register. Function of each bit is shown in the following table.
Bit
7
Description
Set when overheat protection activates
0 at all times
6
5
0 at all times
4
0 at all times
3
0 at all times
2
0 at all times
1
0 at all times
0
0 at all times
The target of read operation is set by the PAGE command. PAGE 00h to 02h sets the output channel 1 to 3,
PAGE 03h sets primary side.
9-6-22 STATUS_CML command (7Eh)
This command is used to read the STATUS_CML register.
The STATUS_CML is a 1 byte register. Function of each bit is shown in the following table.
Bit
7
Description
Set when a command code not found in the list of PMBus command codes is used
6
Set when invalid data are received
Set when Packet Error Check fails
Set when memory read/write fails
0 at all times
5
4
3
2
0 at all times
1
0 at all times
0
0 at all times
9-6-23 STATUS_MFR_SPECIFIC command (80h)
This command is used to read the STATUS_MFR_SPECIFIC register.
The STATUS_MFR_SPECIFIC is a 1 byte register. Function of each bit is shown in the following table.
Description
Bit
7
0 at all times
Set when internal error 6 occurs
Set when internal error 5 occurs
Set when internal error 4 occurs
Set when internal error 3 occurs
Set when internal error 2 occurs
Set when internal error 1 occurs
6
5
4
3
2
1
0
Set when internal error 0 occurs
The meaning of internal errors is not disclosed.
If an internal error occurs repeatedly even after input voltage is reapplied, this may mean that the module is
damaged. When internal error occurs, please contact manufacturer.
30
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
9-6-24 READ_VIN command (88h)
This command is used to read the effective value of input voltage
Data size: 2 bytes, DIRECT Format is used (units: V). Coefficients: m = 1, b = 0, R = 1.
9-6-25 READ_VOUT command (8Bh)
This command is used to read the output voltage.
Data size: 2 bytes, DIRECT Format is used (units: V). Coefficients: m = 1, b = 0, R = 3.
The target output channel for read operation is set by the PAGE command.
9-6-26 READ_IOUT command (8Ch)
This command is used to read the output current.
Data size: 2 bytes, DIRECT Format is used (units: A). Coefficients: m = 1, b = 0, R = 3.
The target output channel for read operation is set by the PAGE command.
9-6-27 READ_TEMPERATURE_1 command (8Dh)
This command is used to read temperature in the device (primary side).
Data size: 2 bytes, DIRECT Format is used (units: °C). Coefficients: m = 1, b = 0, R = 0.
9-6-28 READ_TEMPERATURE_2 command (8Eh)
This command is used to read temperature in the device (secondary side).
Data size: 2 bytes, DIRECT Format is used (units: °C). Coefficients: m = 1, b = 0, R = 0.
The target output channel for read operation is set by the PAGE command.
9-6-29 READ_OPERATING_TIME command (D0h)
This command is used to read the total operating time.
Data size: 2 bytes, DIRECT Format is used (units: days). Coefficients: m = 1, b = 0, R = 0.
9-6-30 READ_ESTIMATED_LIFE command (D1h)
This command is used to read the estimated life.
Data size: 2 bytes, DIRECT Format is used (units: days). Coefficients: m = 1, b = 0, R = 0.
9-6-31 STATUS_BYTE_HISTORY command (D8h)
This command is used to read the history of the STATUS_BYTE register.
Data size: 1 byte.
9-6-32 STATUS_WORD_HISTORY command (D9h)
This command is used to read the history of the STATUS_WORD register.
Data size: 2 bytes.
9-6-33 STATUS_VOUT_HISTORY command (DAh)
This command is used to read the history of the STATUS_VOUT register.
Data size: 1 byte.
9-6-34 STATUS_IOUT_HISTORY command (DBh)
This command is used to read the history of the STATUS_IOUT register.
Data size: 1 byte.
31
BAD20190627_(BAD20170920 G0340E01C)
Bellnix AC-DC Power Supply
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
9-6-35 STATUS_INPUT_HISTORY command (DCh)
This command is used to read the history of the STATUS_INPUT register.
Data size: 1 byte.
9-6-36 STATUS_TEMPERATURE_HISTORY command (DDh)
This command is used to read the history of the STATUS_TEMPERATURE register.
Data size: 1 byte.
9-6-37 STATUS_CML_HISTORY command (DEh)
This command is used to read the history of the STATUS_CML register.
Data size: 1 byte.
9-6-38 STATUS_MFR_SPECIFIC_HISTORY command (E0h)
This command is used to read the history of the STATUS_MFR_SPECIFIC register.
Data size: 1 byte.
10. Vibration and shock testing
Vibration: 5 to 10Hz total amplitude 10mm, 10 to 55Hz acceleration 2G (1 hour in each of 3 directions)
Shock:
acceleration 20G (3 times in each of 3 directions)
shock time 11±5ms
11. Life expectancy
The expected life of the converter is given in the following table.
Life expectancy
(switching frequency 260kHz, output power 100%)
Mounting direction*
Ambient temperature
A
B
40°C or less
40°C or less
6.3 years
4.2 years
*
See chapter 5. Temperature derating
12. Precautions for use
To ensure user's safety, check specifications before using the product and always observe the following
precautions when using it.
The product is intended for use in general electronics equipment (office equipment, communication
equipment, measurement equipment). Do not use the product in medical equipment, nuclear
equipment, trains, and other areas, where human life or property may be directly affected by
damaged product, or in the environment with constant vibration. For any use other than in general
electronics equipment please consult the manufacturer.
While the product has a built-in overcurrent and short-circuit protection, a prolonged short circuit
condition should be avoided as it can damage the product.
The product may be damaged if used under nonstandard electrical or environmental conditions
including temperature, etc. The product must be always used within specifications.
Avoid storing or using the product in places where corrosive gas or dust are generated.
The product may be damaged by static electricity. Take measures against static electricity in the
working environment, such as using grounding straps to discharge the static charge on workers, etc.
Do not replace fuses.
The product contains parts under high voltage. Do not touch the product when input voltage is
applied or right after input voltage is disconnected.
The product contains hot parts. Do not touch the product when input voltage is applied or right after
input voltage is disconnected.
The product does not come with a test report.
32
Bellnix AC-DC Power Supply
BAD20190627_(BAD20170920 G0340E01C)
Semi-Custom AC-DC Converter with Full Digital Control
BDG-200 Series
13. Warranty
The warranty period of this product is one year. Should the product become defective within the warranty
period due defects in design or manufacture, it will be repaired or replaced free of charge. However, this
warranty does not cover products which have been subjected to internal modifications, etc.
The scope of the warranty is limited to this product only.
14. Model names and configurations
The following table shows the correspondence between model names and unit configurations. If a
configuration absent in the table is required, please contact manufacturer.
Rated output
Model
Channel 1
No unit
No unit
No unit
No unit
No unit
No unit
No unit
No unit
No unit
5V
Channel 2
No unit
No unit
No unit
5V
Channel 3
5V
BDG-200-001
BDG-200-002
BDG-200-003
BDG-200-011
BDG-200-012
BDG-200-013
BDG-200-022
BDG-200-023
BDG-200-033
BDG-200-111
BDG-200-112
BDG-200-113
BDG-200-122
BDG-200-123
BDG-200-133
BDG-200-222
BDG-200-223
BDG-200-233
BDG-200-333
12V
24V
5V
5V
12V
24V
12V
24V
24V
5V
5V
12V
12V
24V
5V
5V
5V
12V
24V
12V
24V
24V
12V
24V
24V
24V
5V
5V
5V
12V
5V
12V
5V
24V
12V
12V
12V
12V
12V
24V
24V
24V
33