29502X [BELDEN]

VFD 300% Gnd, 3CIG #12 Str TC, XLPO InsPVC Grd;
29502X
型号: 29502X
厂家: Belden    Belden
描述:

VFD 300% Gnd, 3CIG #12 Str TC, XLPO InsPVC Grd

文件: 总3页 (文件大小:248K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Product: 29502X  
VFD 300% Gnd, 3C+IG #12 Str TC, XLPO Ins+PVC Grd, OS+TC Brd, Blk  
LSZH-TS Jkt, 600V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable  
Marine Approved  
Product Description  
Belden 300% Ground Flexible VFD, 3 Conductor 12AWG (65x30) Tinned Copper, XLPO Insulation M4 Color Code+PVC Insulated Ground, Overall  
Beldfoil®+Tinned Copper Braid(85%) Shield, Black LSZH-TS Outer Jacket, 600V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable Marine Approved  
SUN RES OIL RES II  
Technical Specifications  
Product Overview  
Suitable Applications:  
AC Motor drives, VFD, Variable Frequency drives  
Physical Characteristics (Overall)  
Conductor  
Element  
AWG Stranding  
Material  
No. of Conductors  
12  
65x30  
65x30  
TC - Tinned Copper  
TC - Tinned Copper  
3
Ground Wire 12  
Conductor Count:  
3
Insulation  
Material  
Nominal Wall Thickness  
XLPE - Cross Linked Polyethylene 0.045 in  
XLP - Cross Linked Polyolefin  
Color Chart  
Number  
Color  
1
2
3
4
Black and Numbered 1  
Black and Numbered 2  
Black and Numbered 3  
Green/Yellow  
Outer Shield Material  
Type Layer Material  
Material Trade Name Coverage [%] Drainwire Material Drainwire AWG Drainwire Construction n x D  
Tape  
Braid  
1
2
Aluminum/Polyester Duofoil®  
TC - Tinned Copper  
100 %  
85 %  
TC - Tinned Copper 12  
65x30 mm  
Outer Jacket Material  
Material Nominal Diameter Nominal Wall Thickness  
Haloarrest Xlink 2 0.63 in  
Electrical Characteristics  
Conductor DCR  
0.073 in  
Nominal Conductor DCR  
1.6 Ohm/1000ft  
Capacitance  
Nom. Capacitance Conductor to Conductor Nom. Capacitance Conductor to Other Conductor to Shield  
26 pF/ft  
47 pF/ft  
Inductance  
Nominal Inductance  
0.197 µH/ft  
Impedance  
Nominal Characteristic Impedance  
71 Ohm  
Current  
Max. Recommended Current [A]  
30 Amps per conductor @ 30°C (per NEC)  
Voltage  
Description  
UL Voltage Rating  
Voltage Rating [V]  
CSA AWM I/II A/B 1000 V RMS (Flexible Motor Supply Cable) 1000 V RMS  
600 V RMS (Type TC)  
Temperature Range  
UL Temp Rating:  
Wet Temp Range:  
Dry Temp Range:  
90°C Dry, 90°C Wet  
-40°C To +90 °C  
-40°C To +90 °C  
Mechanical Characteristics  
Bulk Cable Weight:  
250 lbs/1000ft  
Max Recommended Pulling Tension: 336 lbs  
Min Bend Radius/Minor Axis:  
6.3 in  
Standards  
NEC/(UL) Specification:  
CPR Euroclass:  
TC-ER, Unlisted Singles, WTTC  
Fca  
Applicable Environmental and Other Programs  
EU Directive Compliance:  
EU CE Mark:  
EU Directive 2003/11/EC (BFR)  
Yes  
Yes  
Yes  
CA Prop 65 (CJ for Wire & Cable):  
MII Order #39 (China RoHS):  
Suitability  
Suitability - Burial:  
Yes  
Yes  
Yes  
Yes  
Yes  
Suitability - Indoor:  
Suitability - Oil Resistance:  
Suitability - Outdoor:  
Suitability - Sunlight Resistance:  
Flammability, LS0H, Toxicity Testing  
UL Flammability:  
CSA Flammability:  
IEEE Flammability:  
UL voltage rating:  
UL1685 UL Loading  
FT4  
1202  
1000 V RMS (Flexible Motor Supply Cable)  
Part Number  
Variants  
Item #  
Color  
UPC  
Length Footnote  
29502X 0105000 Black 612825136842 5,000 ft C Z  
Footnote:  
Footnote:  
C - CRATE REEL PUT-UP.  
Z - FINAL PUT-UP MAY VARY (= OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.  
History  
Update and Revision:  
Revision Number: 0.198 Revision Date: 09-10-2019  
© 2019 Belden, Inc  
All Rights Reserved.  
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without  
notice, and the listing of such information and specifications does not ensure product availability.  
Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages  
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,  
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.  
All sales of Belden products are subject to Belden's standard terms and conditions of sale.  
Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief  
at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product  
Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and  
regulations based on their individual usage of the product.  

相关型号:

29502X0105000

VFD 300% Gnd, 3CIG #12 Str TC, XLPO InsPVC Grd
BELDEN

29503

VFD 300% Gnd, 3CIG #10 Str TC, XLPO InsPVC Gnd
BELDEN

295030101000

VFD 300% Gnd, 3CIG #10 Str TC, XLPO InsPVC Gnd
BELDEN

29503010250

VFD 300% Gnd, 3CIG #10 Str TC, XLPO InsPVC Gnd
BELDEN

29503010500

VFD 300% Gnd, 3CIG #10 Str TC, XLPO InsPVC Gnd
BELDEN

295030105000

VFD 300% Gnd, 3CIG #10 Str TC, XLPO InsPVC Gnd
BELDEN

2950323

Relays/Accessories,
PHOENIX

29503F

VFD 300% Gnd, 3CIG #10 Str TC, XLPO InsPVC Gnd
BELDEN

29503F0101000

VFD 300% Gnd, 3CIG #10 Str TC, XLPO InsPVC Gnd
BELDEN

29503F0105000

VFD 300% Gnd, 3CIG #10 Str TC, XLPO InsPVC Gnd
BELDEN

29503T

VFD 300% Gnd, 3CIG #10 Str TC
BELDEN

29503T0101000

VFD 300% Gnd, 3CIG #10 Str TC
BELDEN