WLB92ZCY1100PBQMN [BANNER]
WLB92 Industrial LED Light Bar (AC Quick Disconnect);型号: | WLB92ZCY1100PBQMN |
厂家: | Banner Engineering |
描述: | WLB92 Industrial LED Light Bar (AC Quick Disconnect) |
文件: | 总6页 (文件大小:503K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
WLB92 Industrial LED Light Bar (AC Quick
Disconnect)
Datasheet
Banner's WLB92 is a very bright LED fixture/luminaire that features an even light output for a no glare 'glow'. The WLB92 series is
designed for a wide variety of environments and applications, including but not limited to work stations, machine lighting, and low
bay lighting. The WLB92 uses advanced LED lighting technology to provide a high-quality and maintenance free industrial lighting
solution.
•
•
•
•
•
•
•
Increase worker productivity and ergonomics with bright, high-quality, uniform light
Exceptionally energy efficient for overall cost savings
Durable light stands up to your environment with a rugged metal housing and shatter-resistant window
Easy installation with snap clips
Intensity can be controlled from 15% to 100% using the attached knob
Rated for use at 120 V ac in North America
Rated for use at 100 V ac to 277 V ac outside North America
These AC quick disconnect models can be used as continuous run models that can be cascaded or "daisy-chained" together for a
continuous length of lighting using a double-ended accessory cordset (see Accessories (p. 5)). Each light bar can be turned on,
off, or dimmed independently of the other lights, upstream or downstream, in the chain.
WLB92 Industrial LED Light Bars are available in several configurations including different lengths and cord options. WLB92 (AC)
Daylight White and Warm White models come with a five year, limited warranty. To view or download the latest technical
information about this product, including specifications, dimensions, accessories, and wiring, see www.bannerengineering.com.
Important: Lea el siguiente instructivo antes de operar el luminario. Por favor descargue desde
www.bannerengineering.com toda la documentación técnica de los WLB92 Industrial LED Light Bar (AC Quick
Disconnect), disponibles en múltiples idiomas, para detalles del uso adecuado, aplicaciones, advertencias, y las
instrucciones de instalación de estos dispositivos.
Important: Lisez les instructions suivantes avant d'utiliser le luminaire. Veuillez télécharger la documentation
technique complète des WLB92 Industrial LED Light Bar (AC Quick Disconnect) sur notre site
www.bannerengineering.com pour les détails sur leur utilisation correcte, les applications, les notes de sécurité
et les instructions de montage.
Models
Lighted
Control
Family
Voltage Cascadable
Length (mm)
Connector
Plug Type (1.8 m cable)
LED Color
WLB92
Z
C
550
QM
B
PB
Z = AC
C = Cascadable Blank = Daylight White
550
1100
QM = Custom Quick
Disconnect (QD) *
PB = Switch,
Dimming
Knob
B = North & Central America, Japan, Taiwan
D = India, Sri Lanka, Nepal, Namibia
WW = Warm White
G = Green
R = Red
EF = France, Belgium, Slovakia, Tunisia, Germany,
Austria, Netherlands, Spain,
S. Korea
Y = Yellow
B = Blue
G = UK, Ireland, Cyprus, Malta, Malaysia,
Singapore, Hong Kong, Vietnam
* QD models require a mating cordset
I = Australia, New Zealand, Papua New Guinea,
Argentina, China
N = Brazil, South Africa
C = AC connector with flying leads
Blank = no power cord
Original Document
183984 Rev. H
22 August 2019
183984
WLB92 Industrial LED Light Bar (AC Quick Disconnect)
Installing the WLB92 Industrial LED Light Bar (AC Quick Disconnect Models)
Figure 1. Attaching the snap brackets (step 6)
Figure 2. Installing the cascade cover (step 9)
1. Attach the snap brackets to the light.
2. Select a suitable horizontal or vertical dry mounting location. The maximum distance to the power receptacle cannot be
farther than the length of the power cord used.
3. Place the light in the mounting location and mark the positions of the snap bracket mounting holes.
4. Remove the brackets from the light.
5. Drill the holes and use appropriate screws to secure the snap bracket to the mounting location.
6. Snap the light onto the brackets.
7. When installing cascading lights, repeat steps 1 through 6 to mount additional lights. See the application note in the
Specifications section for the maximum cascaded lights and maximum allowed cable run when choosing mounting
locations.
8. Connect the cascaded lights together using an applicable cordset (see Accessories (p. 5)).
9. Install the supplied cover over the output connector on the last light in the chain.
10. Plug the power cord from the first light into the wall outlet. A 3 m (10 ft) cord is available for applications requiring a longer
cord for cabinet installations.
CAUTION: To reduce the risk of fire, electrical shock, or injury to personal:
•
•
Use only insulated staples or plastic ties to secure cords
Route and secure cords so that they will not be pinched or damaged when the cabinet is pushed to the
wall
•
Position the portable cabinet light with respect to the cabinet so the lamp replacement markings are
able to be read during relamping
•
•
Do not recess into ceilings or soffits
Do not conceal the cords. The National Electrical Code (NEC) does not permit cords to be concealed
where damage to insulation may go unnoticed. To prevent fire danger, do not run cords behind walls,
ceilings, soffits, or cabinets where it may be inaccessible for examination. Cords should be visually
examined periodically and immediately replaced when any damage is noted.
CAUTION: To Reduce the Risk of Fire. Do not install the 550 mm models in a compartment smaller than 305
mm by 305 mm by 675 mm. Do not install the 1100 mm models in a compartment smaller than 305 mm by 305
mm by 1350 mm.
2
www.bannerengineering.com - Tel: + 1 888 373 6767
P/N 183984 Rev. H
WLB92 Industrial LED Light Bar (AC Quick Disconnect)
Specifications
Supply Voltage
Construction
Nominal voltage: 120 V ac, 60 Hz in North America
Nominal voltage: 100 V ac to 277 V ac, 50/60 Hz outside North America
Power factor: > 0.95 at 120 V ac and > 0.90 at 230 V ac
Total harmonic distortion (THD): < 20%
Anodized aluminum housing, polycarbonate window and end caps, and
stainless steel mounting brackets
Spacing Criterion
Vertical: 1.20
Horizontal: 1.32
See electrical characteristics on product label
Supply Current
Connections
Integral custom quick disconnect (connecting cordset required)
Typical Current Draw (A)
Lighted Length
(mm)
Max. Current Draw
(A) at 90 V ac
Mounting
120 V ac
230 V ac
Snap mount brackets included (two for the 550 mm model; three for the
1100 mm model)
Compatible with integral 45 mm aluminum framing mounting slots
550
0.425
0.850
0.270
0.540
0.135
0.250
1100
Operating Temperature
550 Lighted Length: –35 °C to +50 °C (–31 °F to +122 °F) for 24 hours per
day for 5 years of operation
1100 Lighted Length: –40 °C to +45 °C (–40 °F to +113 °F) for 16 hours per
day for 5 years of operation; or –40 °C to +35 °C (–40 °F to +95 °F) for 24
hours per day for 5 years of operation
Supply Protection Circuitry
Protected against transient voltages
Light Characteristics
Daylight White and Warm White Efficacy: 110 lumens/watt typical at 120 V
ac at 25 °C (77 °F)
CRI: 82, typical
Storage Temperature
–40 °C to +70 °C (–40 °F to +158 °F)
Vibration and Mechanical Shock
Vibration: 10 Hz to 55 Hz, 0.5 mm peak-to-peak amplitude per IEC
60068-2-6
Shock: 5G 11 ms duration, half sine wave per IEC 60068-2-27
Color
Dominant Wavelength
(nm) or Color
Lighted Length Lumens
(Typical at 25 °C)
Temperature (CCT)
Application Notes
550 mm
3510
1100 mm
When connecting continuous run/cascadable lights in series, see table for
maximum number of units. Do not exceed a maximum wiring distance of
100 m (328 ft) in the main power cable and any cascading cables.
Daylight
White
5000 K ( 300 K)
7150
7150
Maximum Unit Limit (when using both model lengths)
Warm
White
3000 K (+225 K, -125 K)
3510
550 mm Lights
1100 mm Lights
Green
Red
525 nm
625 nm
590 nm
470 nm
1430
745
620
405
2975
1545
1295
840
10
8
0
1
2
3
4
5
6
Yellow
Blue
4
2
0
Test Data
LM-79, LM-80, TM-21
For example, if you use four 550 mm lights, you may add up to three 1100
mm lights within the same continuous run.
Environmental Rating
IEC IP40
Certifications
LED Lifetime
Lumen Maintenance - L70
When operating within specifications, output will decrease less than 30%
after 50,000 hours.
Switch/Dimming Knob
On/Off Switch and dimming knob, dimmable to 15% intensity
Spacing Criteria (SC)
The spacing criteria is the fixture-spacing-to-mounting-height ratio and aids in laying out a pattern of fixtures. Multiply the spacing
criteria by the mounting height to get the maximum fixture spacing that still provides even illumination (no shadowing between
fixtures).
Luminaire Spacing = SC × Height to Illuminated Plane
The mounting height is the distance from the fixture to the surface you are lighting.
P/N 183984 Rev. H
www.bannerengineering.com - Tel: + 1 888 373 6767
3
WLB92 Industrial LED Light Bar (AC Quick Disconnect)
Performance Curves
550 mm Models - Daylight White and Warm White
Illuminance at a Distance
Polar Candela Distribution
Isolux Pattern
6
3
3
6
0 m
Center Beam (lux)
3,630 lux
1,117 lux
496 lux
Beam Width (m)
1.08 m 2.33 m
2.15 m 4.67 m
3.23 m 7.00 m
4.30 m 9.33 m
5.38 m 11.67 m
6.45 m 14.00 m
180°
170°
160°
6
3
1100
917
733
550
367
183
0
150°
140°
130°
0.5 m
1.0 m
1.5 m
2.0 m
120°
110°
100°
279 lux
179 lux
2.5 m
3.0 m
90°
80°
124 lux
0 m
183
367
550
733
917
1100
Vert.
Horiz.
70°
60°
50°
40°
Vertical Spread: 94.2°
Horizontal Spread: 133.6°
3
6
30°
20°
10°
0°
Vertical Angle:
0° Vertical 90° Horizontal
Mount height of 3 meters (3 m)
100 lux
75 lux
50 lux
40 lux
30 lux
20 lux
10 lux
5 lux
50% max.
candela
1100 mm Models - Daylight White and Warm White
Polar Candela Distribution
Isolux Pattern
Illuminance at a Distance
6
3
3
6
0 m
Center Beam (lux)
5,060 lux
1,870 lux
932 lux
Beam Width (m)
1.12 m 2.26 m
2.25 m 4.53 m
3.37 m 6.79 m
4.50 m 9.06 m
5.62 m 11.32 m
6.74 m 13.58 m
180°
170°
160°
6
3
2200
1833
1467
1100
733
150°
140°
130°
0.5 m
1.0 m
1.5 m
2.0 m
120°
110°
100°
524 lux
367
335 lux
2.5 m
3.0 m
0
90°
80°
233 lux
0 m
367
Vert.
Horiz.
733
70°
60°
50°
40°
Vertical Spread: 96.7°
1100
1467
1833
2200
Horizontal Spread: 132.3°
3
6
30°
20°
10°
0°
Vertical Angle:
0° Vertical 90° Horizontal
Mount height of 3 meters (3 m)
200 lux
150 lux
100 lux
75 lux
50 lux
25 lux
10 lux
5 lux
50% max.
candela
Dimensions
L1
L2
104
[4.1]
14
[.56]
97
[3.8]
45
[1.8]
Model
L1
L2
WLB92ZC...550PBQM
WLB92ZC...1100PBQM
543 mm (21.4 in)
1098 mm (43.2 in)
651 mm (25.6 in)
1206 mm (47.5 in)
4
www.bannerengineering.com - Tel: + 1 888 373 6767
P/N 183984 Rev. H
WLB92 Industrial LED Light Bar (AC Quick Disconnect)
Accessories
Wall Plug Cordsets
Model
Plug Type
Countries
Length
Dimensions
LQMAC-306
Flying Leads
NEMA 5-15 grounded (IEC Type
B)
United States, Canada, Japan,
Puerto Rico, Taiwan
LQMAC-306B
LQMAC-306D
BS 546 (IEC Type D)
India
Germany, France, South Korea,
The Netherlands, Poland, Spain,
Turkey
38
LQMAC-306EF
LQMAC-306G
CEE 7/7 (IEC Type E or F)
1.8 m (6 ft)
10
United Kingdom, Ireland,
Singapore, Vietnam
BS 1363 (IEC Type G)
LQMAC-306I
LQMAC-306N
AS/NZS 3112 (IEC Type I)
NBR 14136 (IEC Type N)
China, Australia, New Zealand
Brazil
18
NEMA 5-15 grounded (IEC Type
B)
United States, Canada, Japan,
Puerto Rico, Taiwan
LQMAC-310B
3 m (10 ft)
For other lengths of the LQMAC-306 cables, contact the factory. LQMAC-310B is available for applications requiring a 3 m (10 ft)
cord for cabinet installation. For complete listing of countries and wall plug types, see the IEC World Plugs website.
Continuous Run/Cascade Cordsets
Model
Length
Style
Dimensions
LQMAEC-3005SS
LQMAEC-301SS
LQMAEC-303SS
LQMAEC-306SS
LQMAEC-312SS
LQMAEC-320SS
LQMAEC-330SS
0.15 m (0.5 ft)
0.31 m (1 ft)
0.91 m (3 ft)
1.83 m (6 ft)
3.66 m (12 ft)
6.1 m (20 ft)
9.14 m (30 ft)
38
Male straight/Male straight
10
14
38
18
14
Brackets
LMBWLB92CLIP
89
•
•
•
Snap clip allows for tool-less installation
Stainless steel
20
Ø6.5
Includes four snap clips, four screws, and
two insulator caps
The LMBWLB92CLIP bracket replaces the bracket that ships
with the WLB92 light.
P/N 183984 Rev. H
www.bannerengineering.com - Tel: + 1 888 373 6767
5
WLB92 Industrial LED Light Bar (AC Quick Disconnect)
Banner Engineering Corp. Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for five years on daylight white and warm white models and one year on all other
models following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is
found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner
product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO
BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES
RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT,
STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously
manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the
product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will
void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at
any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to:
www.bannerengineering.com.
For patent information, see www.bannerengineering.com/patents.
FCC Part 15 and CAN ICES-3 (B)/NMB-3(B)
This device complies with part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions:
1.
2.
This device may not cause harmful interference, and
This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
•
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the manufacturer.
Mexican Importer
Banner Engineering de Mèxico, S. de R.L. de C.V.
David Alfaro Siqueiros 103 Piso 2 Valle oriente
San Pedro Garza Garcia Nuevo Leòn, C. P. 66269
81 8363.2714
©
Banner Engineering Corp. All rights reserved
相关型号:
©2020 ICPDF网 联系我们和版权申明