SG-TL70-GY [BANNER]
TL70 Multicolor Tower Light Module;型号: | SG-TL70-GY |
厂家: | Banner Engineering |
描述: | TL70 Multicolor Tower Light Module |
文件: | 总2页 (文件大小:118K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
TL70 Multicolor Tower Light Module
Datasheet
Models
Example Models:
TL70 Multicolor Segments
SG-TL70-GYR (3 color: green, yellow, red)
SG-TL70-GR (2 colors: green, red)
SG-TL70-GY (2 colors: green, yellow)
Colors
Housing
Housing Color
Y
R
G
SG-TL70
TL70 Segment
Green
Yellow
G =
Y =
Blank = Black
C = Gray
R = Red
B = Blue
W = White
For more information regarding TL70 Modular Tower Light Final Assemblies, refer to the following documents:
•
•
•
TL70 Modular Tower Light Final Assembly Datasheet (p/n 182214)
TL70 Wireless Modular Tower Light Datasheet (p/n 185469)
TL70 Modular Tower Light Final Assembly For AC Datasheet (p/n 191349)
Configuring the Module
DIP Switches
Assembly Options
1
2
3 Hz
ON
ON
OFF
ON
1.5 Hz
Light Module Flash Rate
OFF
OFF
Solid On*
* Factory default setting
Wiring Diagrams
PNP Input
M12 Male Pinouts
Key
1 = brown
2 = white
3 = blue
4 = black
5 = gray
3
Module
1
12–30 V dc
2
4
1
2
5
C1M1
4
5
C1M1 = Color 1 Module 1
C2M1 = Color 2 Module 1
C3M1 = Color 3 Module 1
M2 = Module 2
3
C2M1
C3M1
M2
Original Document
188350 Rev. E
6 December 2017
188350
TL70 Multicolor Tower Light Module
Specifications
Supply Voltage and Current
Environmental Rating
IEC IP65
12 V dc to 30 V dc
Indicators - Maximum current per LED color:
Blue, Green, White: 420 mA at 12 V dc; 150 mA at 30 V dc
Red, Yellow: 285 mA at 12 V dc; 120 mA at 30 V dc
Vibration and Mechanical Shock
Vibration 10 Hz to 55 Hz 0.5 mm p-p amplitude per IEC 60068-2-6
Shock 15G 11 ms duration, half sine wave per IEC 60068-2-27
Supply Protection Circuitry
Required Overcurrent Protection
Protected against transient voltages
WARNING: Electrical connections must be
made by qualified personnel in accordance with
local and national electrical codes and
regulations.
Indicator Response Time
Off Response: 150 µs (maximum) at 12 V dc to 30 V dc
On Response: 180 ms (maximum) at 12 V dc; 50 ms (maximum) at 30 V dc
Indicator Characteristics
Overcurrent protection is required to be provided by end product
application per the supplied table.
Overcurrent protection may be provided with external fusing or via Current
Limiting, Class 2 Power Supply.
Dominant Wavelength (nm) or Color
Color
Lumen Output (Typical at 25° C)
Temperature (CCT)
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to www.bannerengineering.com.
Green
Red
525 nm
92
40
625 nm
Supply Wiring (AWG)
Required Overcurrent Protection (Amps)
Yellow
Blue
590 nm
22
20
22
24
26
28
30
5.0
3.0
2.0
1.0
0.8
0.5
470 nm
32
White
5000 K
125
Construction
Bases, segments, covers: polycarbonate
Indicators
2 or 3 colors depending on model: Green, Red, Yellow, Blue, and White
Flash rates: 1.5 Hz 10ꢀ and 3 Hz 10ꢀ
LEDs are independently selected
Certifications
Operating Conditions
–40 °C to +50 °C (–40 °F to +122 °F)
95ꢀ at +50 °C maximum relative humidity (non-condensing)
Banner Engineering Corp. Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or
replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not
cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO
BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES
RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT,
STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously
manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the
product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will
void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at
any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to:
www.bannerengineering.com.
©
Banner Engineering Corp. All rights reserved