Q45AD9FP [BANNER]
Q45AD9 NAMUR Series Sensor;型号: | Q45AD9FP |
厂家: | Banner Engineering |
描述: | Q45AD9 NAMUR Series Sensor |
文件: | 总10页 (文件大小:613K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Q45AD9 NAMUR Series Sensor
Datasheet
No revision without agency approval.
•
Designed for use with approved amplifiers and intrinsically safe barriers in
explosive environments
•
•
•
NAMUR compliant sensor with the rugged design and excepꢀonal opꢀcal
performance of Q45 series sensors
Output passes ≤ 1.2 mA in the “dark” condiꢀon and ≥ 2.1 mA in the “light”
condiꢀon
Internal mulꢀ-turn SENSITIVITY (Gain) control accessible beneath hinged, o-ring
sealed top cover
•
•
Models are available with an integral cable or a quick-disconnect connector
Supply voltage: 5 to 15 V dc
WARNING: Not To Be Used for Personnel Protecꢀon
Never use this device as a sensing device for personnel protecꢀon. Doing so could lead to serious injury or death.
This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety
applicaꢀons. A sensor failure or malfuncꢀon can cause either an energized or de-energized sensor output
condiꢀon.
Models
Standard 2 m (6.5 ꢁ) cable models are listed. To order the 9 m (30 ꢁ) cable model, add suffix "W/30" to the cabled model number
(Q459E W/30). Models with a QD connector require a maꢀng cable (see Accessories list).
Opposed Models - Emiꢁer (E) and Receiver (R)
Models
Cable
Performance
Output Type
Q459E
2 m (6.5 ꢁ)
4-Pin Euro QD
2 m (6.5 ꢁ)
4-Pin Euro QD
Constant current
Q459EQ
Q45AD9R
Q45AD9RQ
880 nm, infrared
≤ 1.2 mA dark
≥ 2.1 mA light
Range: 6meters (20 feet)
Retroreꢂecꢀve Models
Retroreꢂecꢀve range is specified using one model BRT-3 P retroreꢂector (3-inch diameter). Actual sensing range may be more or less
than specified, depending upon the efficiency and reꢂecꢀve area of the retroreꢂector(s) in use.
Non-Polarized Models
Cable
Performance
Output Type
Q45AD9LV
2 m (6.5 ꢁ)
Constant Current
680 nm, visible red
≤ 1.2 mA dark
≥ 2.1 mA light
Range: 9 m (30 ꢁ)
Q45AD9LVQ
4-pin Euro QD
Polarized Models
Cable
Performance
Output Type
Q45AD9LP
2 m (6.5 ꢁ)
Constant Current
680 nm, visible red
≤ 1.2 mA dark
≥ 2.1 mA light
Range: 6 m (20 ꢁ)
Q45AD9LPQ
4-pin Euro QD
Diffuse Models
Performance curves are based on a 90% reꢂectance white test card.
Original Document
38343 Rev. K
3 April 2017
38343
Q45AD9 NAMUR Series Sensor
Short Range Models
Cable
Performance
Output Type
Q45AD9D
2 m (6.5 ꢁ)
Constant Current
880 nm, infrared
≤ 1.2 mA dark
≥ 2.1 mA light
Range: 300 mm (12 in)
Q45AD9DQ
4-pin Euro QD
Long Range Models
Cable
Performance
Output Type
Q45AD9DL
2 m (6.5 ꢁ)
Constant Current
880 nm, infrared
Range: 1 m (40 in)
≤ 1.2 mA dark
≥ 2.1 mA light
Q45AD9DLQ
4-pin Euro QD
Convergent Models
Convergent mode models operate at 680 nm, visible red. Performance curves are based on a 90% reꢂectance white test card.
Models
Cable
Focus
Output Type
Q45AD9CV
2 m (6.5 ꢁ)
Constant Current
38 mm (1.5 in)
≤ 1.2 mA dark
≥ 2.1 mA light
Spot size at focus: 1.3 mm (0.05 in)
Q45AD9CVQ
Q45AD9CV4
Q45AD9CV4Q
4-pin Euro QD
2 m (6.5 ꢁ)
Constant Current
100 mm (4 in)
≤ 1.2 mA dark
≥ 2.1 mA light
Spot size at focus: 1.5 mm (0.06 in)
4-pin Euro QD
Plasꢀc Fiber Opꢀc Models
Performance curves are based on a 90% reꢂectance white test card.
Models
Cable
Performance
Output Type
Q45AD9FP
2 m (6.5 ꢁ)
660 nm, visible red
Constant Current
Range: varies by sensing mode and fiber
opꢀcs used
≤ 1.2 mA dark
≥ 2.1 mA light
Q45AD9FPQ
4-pin Euro QD
Glass Fiber Opꢀc Models
Performance curves are based on a 90% reꢂectance white test card.
Models
Cable
Performance
Output Type
Q45AD9F
2 m (6.5 ꢁ)
880 nm, infrared
Constant Current
Range: varies by sensing mode and fiber
opꢀcs used
≤ 1.2 mA dark
≥ 2.1 mA light
Q45AD9FQ
4-pin Euro QD
Models
Cable
Performance
Output Type
Q45AD9FV
2 m (6.5 ꢁ)
650 nm, visible red
Constant Current
Range: varies by sensing mode and fiber
opꢀcs used
≤ 1.2 mA dark
≥ 2.1 mA light
Q45AD9FVQ
4-pin Euro QD
Overview
The Q45AD9 Series NAMUR Sensor is a rugged, self-contained two-wire sensor designed for use with cerꢀfied intrinsically safe switching
amplifiers and barriers (Approved Apparatus) with intrinsically safe circuits.
The Q45AD9 Series NAMUR sensor is designed in accordance with DIN 19234 (IEC/EN 60947-5-6) for operaꢀon via two-wire connecꢀon
to an Approved Apparatus controlled by the variable internal resistance of the sensor.
The sensor varies the impedance across the sensor output, which passes 1 mA or less in the "dark" condiꢀon and 2 mA or more in the
"light" condiꢀon. A highly visible red LED indicator is located beneath a raised transparent dome on top of the sensor.
•
•
SIGNAL—LED lights red when the sensor sees its modulated light source
POWER (Emiꢃers only)—LED lights red when 5 to 15 V dc power is applied
Mulꢀ-turn sensiꢀvity control on top of sensor, beneath a transparent cover, allows precise sensiꢀvity seꢄng (turn clockwise to increase
gain).
2
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 38343 Rev. K
Q45AD9 NAMUR Series Sensor
Models are available with either a 2 m (6.5 ꢁ) or 9 m (30 ꢁ) long aꢃached PVC-covered cable, or a 4-pin M12/Euro-style quick
disconnect (QD) connector. Quick disconnect models (with Q in the model number suffix) use MQD9-4.. maꢀng cable (either straight or
right angle connector; see Accessories on page 9). Contact Banner Engineering for the availability of sensor models with 9 m (30 ꢁ)
long aꢃached cable.
Installaꢀon Instrucꢀons
Ex/HazLoc Applicaꢀons
WARNING:
•
•
Explosive Atmospheres/Hazardous Locaꢀons
The user has the responsibility to ensure that all local, state, and naꢀonal laws, rules, codes, or regulaꢀons
relaꢀng to the installaꢀon and use of this Banner device in any parꢀcular applicaꢀon are saꢀsfied. This
Banner device must be installed by Qualified Persons, in accordance with this document and applicable
regulaꢀons.
•
A Qualified Person is a person who, by possession of a recognized degree or cerꢀficate of professional
training, or who, by extensive knowledge, training and experience, has successfully demonstrated the
ability to solve problems relaꢀng to the subject maꢃer and work.
WARNING:
•
•
Explosion Hazard
Do not disconnect equipment unless the power has been switched off or the area is known to be non-
hazardous.
CAUTION: Electrostaꢀc Discharge (ESD)
Special Condiꢀons for Safe Use. Parts of the enclosure are non-conducꢀng and may generate an igniꢀon-capable
level of ESD. Cleaning of the equipment shall be done only with a damp cloth.
General Notes and Condiꢀons for Safe Use:
•
See Specificaꢀons and Wiring Diagrams for important informaꢀon concerning enꢀty parameters, permissible locaꢀons,
electrical connecꢀons and cerꢀficaꢀons.
•
In addiꢀon to the warning above concerning user responsibility, the installaꢀon must comply with the following:
◦
◦
All installaꢀons must comply with all manufacturer's instrucꢀons.
®
®
U.S. Installaꢀons: The relevant requirements of the Naꢀonal Electrical Code (ANSI/NFPA-70 (NEC ) and when
appropriate ANSI/ISA-RP12.06.01 Installaꢀon of Intrinsically Safe Systems for Hazardous (Classified) Locaꢀons.
Canadian Installaꢀons: The relevant requirements of the Canadian Electrical Code (CSA C22.1).
◦
◦
ATEX and IECEx Installaꢀons: The relevant requirements of EN 60079-14 and applicable Naꢀonal regulaꢀons.
•
•
Do not aꢃempt any repairs to this Banner device; it contains no field-replaceable parts or components. Tampering and/or
replacement with non-factory components may adversely affect the safe use of the system.
Approved Apparatus enꢀty parameters must meet the following requirements:
◦
◦
◦
◦
Voc or Vt ≤ Vmax
Ca ≥ Ci + Ccable
Isc or It ≤ Imax
La ≥ Li + Lcable
•
Sensor Enꢀty Parameters:
◦
◦
◦
◦
◦
Vmax (Ui) ≤ 15 V dc
Imax (li) ≤ 60 mA
Pi ≤ 225 mW
Ci = 0.3 μF
Li = 0 mH
•
Cable Enꢀty Parameters (if unknown):
◦
◦
Ccable = 60 pF/ꢁ
Lcable = 0.2 µH/ꢁ
•
•
•
The ambient operaꢀng temperature range of the Sensors is −40 °C to +70 °C (−40 °F to +158 °F).
For U.S. installaꢀons, Class II and III, Division 2 applies only to model numbers ending in a Q suffix.
For intrinsically safe installaꢀons, sensors must be used with cerꢀfied intrinsically safe switching amplifiers and barriers
(Approved Apparatus) with intrinsically safe circuits that limit supply voltage and current in the event of failures.
Associated Apparatus is not required for installaꢀon of the devices within a Division 2 hazardous (classified) locaꢀon when
installed per the Naꢀonal Electrical Code. The maximum voltage for Division 2 installaꢀon is 15V dc. In Division 2 installaꢀons
(without Associated Apparatus), observe Explosion Hazard warning at the beginning of this secꢀon.
Associated Apparatus is not required for installaꢀon of the devices within a Division 2 hazardous (classified) locaꢀon when
installed in, or through the wall of a suitable enclosure with provision for connecꢀon of rigid metal conduit per the Canadian
Electrical Code, as acceptable to the local inspecꢀon authority having jurisdicꢀon. The maximum raꢀng for Division 2
installaꢀon is 15V dc, 60 mA. In Division 2 installaꢀons (without Associated Apparatus), observe Explosion Hazard warning at
the beginning of this secꢀon.
•
•
•
Maximum non-hazardous area voltage that the Approved Apparatus (intrinsically safe circuit) is connected to must not exceed
250V.
P/N 38343 Rev. K
www.bannerengineering.com - Tel: +1-763-544-3164
3
Q45AD9 NAMUR Series Sensor
•
•
Intrinsic safety ground, if required for the Associated Apparatus, shall be less than 1 ohm.
Maximum connector torque: 6 ꢁ-lbs.
Wiring Connecꢀons
Q45AD9 Series NUMAR sensors are intrinsically safe ONLY when used with cerꢀfied intrinsically safe switching amplifiers and barriers
(Approved Apparatus) with intrinsically safe circuits. Banner does not manufacture such devices; however, our applicaꢀons engineers
can refer you to suppliers of cerꢀfied devices that will interface with Banner sensors.
The user is responsible for proper installaꢀon and maintenance of this equipment, and must conform with the cerꢀficaꢀon
requirements relaꢀng to barriers and to maximum allowable capacitance and inductance of the field wiring. If in doubt about these
requirements, our applicaꢀons engineers can refer you to the appropriate authority.
NAMUR Sensors with Aꢁached Cable
NAMUR Sensors with Quick-Disconnect
Hazardous Area
Non-hazardous Area
Hazardous Area
Non-hazardous Area
NAMUR Sensor
Approved Apparatus
NAMUR Sensor
Approved Apparatus
1
2
3
4
br
+
Sensor
Input
Power
≤ 15 V dc
≤ 15 V dc
bu
Power
br
–
+
Sensor
Input
bu
–
Output
Output
Speciꢃcaꢀons for Q45 NAMUR Sensors
Supply Voltage and Current
Indicators
5 to 15 V dc. Supply voltage is provided by the amplifier to which the sensor is
Indicator LEDs are highly visible, located beneath a raised transparent dome on
connected.
top of the sensor.
POWER (red) LED (emiꢃers only) lights whenever 5 to 15 V dc power is applied
SIGNAL (red) LED lights whenever the sensor sees its modulated light source
Adjustments
Mulꢀ-turn sensiꢀvity control on top of sensor, beneath a transparent o-ring
sealed cover, allows precise sensiꢀvity seꢄng (turn clockwise to increase gain).
Connecꢀons
PVC-jacketed 2 m (6.5 ꢁ) or 9 m (30 ꢁ) cables, or 4-pin Euro-style quick-
disconnect (QD) fiꢄng are available. QD cables are ordered separately. See
Accessories.
Output
Constant current output: ≤ 1.2 mA in the “dark” condiꢀon and ≥ 2.1 mA in the
“light” condiꢀon
Operaꢀng Condiꢀons
Output Response Time
Temperature: −40 °C to +70 °C (−40 °F to +158 °F)
Maximum relaꢀve humidity: 90% at 50 °C (non-condensing)
Opposed mode receiver: 2 milliseconds on/0.4 milliseconds off. All others 5
milliseconds on/off (does not include amplifier response)
Cerꢀꢃcaꢀons
Construcꢀon
®
Molded thermoplasꢀc polyester housing, o-ring sealed transparent Lexan top
cover, molded acrylic lenses, and stainless steel hardware. Q45s are designed
to withstand 1200 psi washdown. The base of cabled models has a 1/2-inch
1
NPS integral internal conduit thread.
Environmental Raꢀng
Banner tested to NEMA 6P, IEC IP67
Applicaꢀon Note
Special Condiꢀons for Safe Use: Parts of the enclosure are non-conducꢀng and
may generate an igniꢀon-capable level of ESD. Cleaning of the equipment must
be done only with a damp cloth.
IEC IECEx FMG 14.0029X
ATEX FM12ATEX0094X
FM CoC 0003046293 (US)
FM CoC 0003046293C (CAN)
Design Standards
ATEX (European)
Canada
EN 60079-0, EN 60079-11 and EN 60079-26
CAN/CSA C22.2: No.0-M91, No.142-M1987, No.157-92, No.213-M1987, No.1010.1, E60079-0 and E60079-11
FM Class 3600, 3610, and 3810; ANSI/ISA 61010-1 (82.02.01), 60079-0 and 60079-11
IEC 60079-0, IEC 60079-11
United States
IECEx
1
®
Lexan is a registered trademark of General Electric Co.
4
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 38343 Rev. K
Q45AD9 NAMUR Series Sensor
Approvals
Q45AD9(a)(b),
Q459E(b)
a = Sensing mode D, DL, F, FP, FV, LV, LP, CV, CV4 or R.
b = Connecꢀon method Q or blank
ATEX (European)
II 1 G Ex ia IIC T5 Ta = -40°C to 70°C - 38343; Enꢀty
Enꢀty Parameters: U = 15 V dc, I = 60 mA, P = 225 mW, C = 0.3 μF, L = 0 mH.
i
i
i
i
i
Canadian
IS / I,II,III / 1 / ABCDEFG / T5 Ta = -40°C to 70°C - 38343; Enꢀty
I / 0 / Ex ia / IIC / T5 Ta = -40°C to 70° C - 38343; Enꢀty
(Non-incendive) NI / I / 2 / ABCD / T5 Ta = -40°C to 70°C
Enꢀty Parameters: V
= 15 V dc, I
= 60 mA, P = 225 mW, C = 0.3 μF, L = 0 mH
Max i i i
Max
United States
IS / I,II,III / 1 / ABCDEFG / T5 Ta = -40°C to 70°C - 38343; Enꢀty
I / 0 / AEx ia / IIC / T5 Ta = -40°C to 70°C - 38343; Enꢀty
(Non-incendive) NI / I / 2 / ABCD / T5 Ta = -40°C to 70°C
S / II,III / 2 / FG* / T5 Ta = -40°C to 70°C
*Class II and III, Division 2 applies only to model numbers ending in a Q suffix.
Enꢀty Parameters: V = 15 V dc, I
= 60 mA, P = 225 mW, C = 0.3 μF, L = 0 mH
Max
Max
i
i
i
IECEx
Ex ia IIC T5 Ta= -40 °C to +70 °C - 35331; Enꢀty
Enꢀty Parameters: U = 15 V dc, I = 60 mA, C = 0.3 μF, L = 0 mH.
i
i
i
i
Performance Curves
Opposed
Excess Gain
Beam Paꢁern
1000
Q45AD9 E/R
Opposed Mode
E
X
C
Q45AD9 E/R
Opposed Mode
100
150 mm
6 in
E
S
S
100 mm
50 mm
4 in
2 in
0
0
10
G
50 mm
100 mm
150 mm
2 in
4 in
6 in
A
I
N
1
0.1 m
0.33 ft
1.0 m
3.3 ft
10 m
33 ft
100 m
330 ft
0
1.2 m
4 ft
2.4 m
8 ft
3.6 m
12 ft
4.8 m
16 ft
6 m
20 ft
DISTANCE
DISTANCE
P/N 38343 Rev. K
www.bannerengineering.com - Tel: +1-763-544-3164
5
Q45AD9 NAMUR Series Sensor
Retroreꢂecꢀve Non-Polarized
Excess Gain Beam Paꢁern
Retroreꢂecꢀve Polarized
Excess Gain Beam Paꢁern
1000
1000
Q45AD9LP
Q45AD9LV
E
X
C
E
S
S
E
X
C
E
S
S
Retroreflective Mode
Retroreflective Mode
Q45AD9LV
Retroreflective Mode
100
10
Q45AD9LP
Retroreflective
Mode
100
10
75 mm
3.0 in
75 mm
3.0 in
50 mm
25 mm
2.0 in
1.0 in
0
50 mm
25 mm
2.0 in
1.0 in
0
With BRT-3 Reflector
0
With BRT-3 Reflector
0
With BRT-3 Reflector
G
A
I
G
A
I
25 mm
50 mm
75 mm
1.0 in
2.0 in
3.0 in
25 mm
50 mm
75 mm
1.0 in
2.0 in
3.0 in
With BRT-3 Reflector
N
N
1
1
.01 m
.033 ft
.10 m
.33 ft
1.0 m
3.3 ft
10 m
33 ft
0
3 m
10 ft
6 m
20 ft
9 m
30 ft
12 m
40 ft
15 m
50 ft
.01 m
.033 ft
.10 m
.33 ft
1.0 m
3.3 ft
10 m
33 ft
0
1.5 m
5 ft
3 m
10 ft
4.5 m
15 ft
6 m
20 ft
7.5 m
25 ft
DISTANCE
DISTANCE
DISTANCE
DISTANCE
Diffuse Short Range
Beam Paꢁern
Diffuse Long Range
Excess Gain
Excess Gain
Beam Paꢁern
1000
1000
Q45AD9DL
Diffuse Mode
Q45AD9D
E
X
C
E
S
S
E
X
C
E
S
S
Diffuse Mode
Q45AD9DL
Diffuse Mode
15 mm
0.6 in
100
10
100
10
Q45AD9D
Diffuse Mode
7.5 mm
0.3 in
10 mm
5 mm
0
0.4 in
0.2 in
0
5.0 mm
2.5 mm
0.2 in
0.1 in
0
0
G
A
I
G
A
I
5 mm
10 mm
15 mm
0.2 in
0.4 in
0.6 in
2.5 mm
5.0 mm
7.5 mm
0.1 in
0.2 in
0.3 in
N
N
1
1
1.0 mm
0.04 in
10 mm
0.4 in
100 mm
4.0 in
1000 mm
40 in
0
100 mm 200mm 300 mm 400 mm 500 mm
4.0 in 8.0 in 12.0 in 16.0 in 20.0 in
0
0.3 m
1 ft
0.6 m
2 ft
0.9 m
3 ft
1.2 m
4 ft
1.5 m
5 ft
0.01 m
0.033 ft
0.1 m
0.33 ft
1 m
3.3 ft
10 m
33 ft
DISTANCE
DISTANCE
DISTANCE
DISTANCE
Convergent (CV and CVQ Models)
Excess Gain Beam Paꢁern
Convergent (CV4 and CV4Q Models)
Excess Gain Beam Paꢁern
1000
1000
Q45AD9CV
Q45AD9CV4
E
X
C
E
S
S
E
X
C
E
S
S
Convergent Mode
Convergent Mode
Q45AD9CV4
100
10
Q45AD9CV
100
10
3.8 mm
0.15 in
3.8 mm
0.15 in
Convergent Mode
Convergent Mode
2.5 mm
1.2 mm
0.10 in
0.05 in
0
2.5 mm
1.2 mm
0.10 in
0.05 in
0
0
0
G
A
I
G
A
I
1.2 mm
2.5 mm
3.8 mm
0.05 in
0.10 in
0.15 in
1.2 mm
2.5 mm
3.8 mm
0.05 in
0.10 in
0.15 in
N
N
1
1
1 mm
.04 in
10 mm
.4 in
100 mm
4 in
1000 mm
40 in
0
38 mm
1.5 in
75 mm 113 mm 150 mm 190 mm
3.0 in 4.5 in 6.0 in 7.5 in
1 mm
.04 in
10 mm
.4 in
100 mm
4 in
1000 mm
40 in
0
38 mm
1.5 in
75 mm 113 mm 150 mm 190 mm
3.0 in 4.5 in 6.0 in 7.5 in
DISTANCE
DISTANCE
DISTANCE
DISTANCE
6
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 38343 Rev. K
Q45AD9 NAMUR Series Sensor
Plasꢀc Fiber Opꢀc (Opposed Mode)
Excess Gain Beam Paꢁern
Plasꢀc Fiber Opꢀc (Diffuse Mode)
Excess Gain Beam Paꢁern
1000
100
10
1000
100
10
Q45AD9FP
Diffuse Mode
Q45AD9FP
E
X
C
E
S
S
E
X
C
E
S
S
Opposed Mode
Q45AD9FP
Diffuse Mode
Q45AD9FP
Opposed Mode
45 mm
1.8 in
2.4 mm
0.09 in
30 mm
15 mm
1.2 in
0.6 in
0
PBT46U Fiber
PIT46U Fibers
1.6 mm
0.8 mm
0.06 in
0.03 in
0
PBT46U Fiber
PIT46U Fibers
0
0
G
A
I
PIT26U Fibers
G
A
I
15 mm
30 mm
45 mm
0.6 in
1.2 in
1.8 in
0.8 mm
1.6 mm
2.4 mm
0.03 in
0.06 in
0.09 in
PIT26U Fibers
N
N
PBT26U Fiber
1
1
0.1 mm
0.004 in
1 mm
0.04 in
10 mm
0.4 in
100 mm
4 in
0
10 mm
0.4 in
20 mm
0.8 in
30 mm
1.2 in
40 mm 50 mm
1.6 in 2.0 in
1 mm
0.04 in
10 mm
0.4 in
100 mm
4.0 in
1000 mm
40 in
0
25 mm
1.0 in
50 mm
2.0 in
75 mm 100 mm 125 mm
3.0 in 4.0 in 5.0 in
DISTANCE
DISTANCE
DISTANCE
DISTANCE
Glass Fiber Opꢀc, Infrared (Opposed Mode)
Excess Gain Beam Paꢁern
Glass Fiber Opꢀc, Infrared (Diffuse Mode)
Excess Gain Beam Paꢁern
1000
1000
Q45AD9F
Q45AD9F
E
X
C
E
S
S
E
X
C
E
S
S
Diffuse Mode
Opposed Mode
Opposed Mode
IT13S Fibers
Q45AD9F
100
10
100
10
Q45AD9F
Diffuse Mode
37.5 mm
1.5 in
1.5 mm
0.06 in
25.0 mm
12.5 mm
1.0 in
0.5 in
0
IT23S fibers
1.0 mm
0.5 mm
0.04 in
0.02 in
0
IT23S Fibers
BT23S fiber
BT23S Fiber
BT13S Fiber
0
0
G
A
I
G
A
I
IT13S fibers
12.5 mm
25.0 mm
37.5 mm
0.5 in
1.0 in
1.5 in
0.5 mm
1.0 mm
1.5 mm
0.02 in
0.04 in
0.06 in
N
N
BT13S fiber
1
1
1.0 mm
0.04 in
10 mm
0.4 in
100 mm
4 in
1000 mm
40 in
1.0 mm
0.04 in
10 mm
0.4 in
100 mm
4 in
1000 mm
40 in
0
125 mm 250 mm 375 mm 500 mm 625 mm
5 in 10 in 15 in 20 in 25 in
0
12.5 mm 25.0 mm 37.5 mm 50.0 mm 62.5 mm
0.5 in 1.0 in 1.5 in 2.0 in 2.5 in
DISTANCE
DISTANCE
DISTANCE
DISTANCE
Glass Fiber Opꢀc, Visible Red (Opposed Mode)
Excess Gain Beam Paꢁern
Glass Fiber Opꢀc, Visible Red (Diffuse Mode)
Excess Gain Beam Paꢁern
1000
1000
Q45AD9FV
Q45AD9FV
E
X
C
E
S
S
E
X
C
E
S
S
Opposed Mode
IT23S Fibers
Diffuse Mode
Q45AD9FV
Diffuse Mode
Q45AD9FV
Opposed Mode
100
10
3.0 mm
0.12 in
30 mm
1.2 in
100
10
2.0 mm
1.0 mm
0.08 in
0.04 in
0
20 mm
10 mm
0.8 in
0.4 in
0
IT23S Fibers
BT13S Fiber
0
0
G
A
I
G
A
I
1.0 mm
2.0 mm
3.0 mm
0.04 in
0.08 in
0.12 in
10 mm
20 mm
30 mm
0.4 in
0.8 in
1.2 in
IT13S Fibers
IT13S Fibers
BT13S
Fiber
BT23S Fiber
BT23S Fiber
N
N
1
1
1.0 mm
0.04 in
10 mm
0.4 in
100 mm
4 in
1000 mm
40 in
0
5 mm
0.2 in
10 mm
0.4 in
15 mm
0.6 in
20 mm 25 mm
0.8 in 1.0 in
0
100 mm 150 mm 200 mm 250 mm 300 mm
4 in 6 in 8 in 10 in 12 in
1 mm
0.04 in
10 mm
0.4 in
100 mm
4.0 in
1000 mm
40 in
DISTANCE
DISTANCE
DISTANCE
DISTANCE
P/N 38343 Rev. K
www.bannerengineering.com - Tel: +1-763-544-3164
7
Q45AD9 NAMUR Series Sensor
Dimensions
NAMUR Series Opposed, Retro, and Diffuse Sensing Modes (Model Suffix E, R, D, DL, LP, and LV)
Cabled Models Quick-Disconnect 4-pin Euro-style Models
54.1 mm
(2.13")
44.5 mm
(1.75")
Lens Centerline
50.8 mm
(2.00")
69.0 mm
(2.72")
6.4 mm (0.25")
87.6 mm
(3.45")
4.5 mm (#10) Screw
Clearance (2)
7.1 mm
(0.28")
30.0 mm
(1.18")
Internal Thread
(1/2–14NPSM)
ø 6.1 (0.24")
2m (6.5') Cable
External thread (M30 x 1.5)
hex nut supplied
Euro- or Micro-style
QD Connector
15 mm (0.6")
Convergent Sensor Models (CV and CV4)
Glass Fiber Opꢀc Models (F and FV)
Plasꢀc Fiber Opꢀc Models (FP)
60.5 mm
(2.38")
61.7 mm
(2.43")
59.9 mm
(2.36")
8
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 38343 Rev. K
Q45AD9 NAMUR Series Sensor
Accessories
Quick-Disconnect (QD) Cables
4-Pin Threaded M12/Euro-Style Cordsets (for use with NAMUR sensors)
Model
Length
Style
Dimensions
Pinout (Female)
MQD9-406
MQD9-415
1.83 m (6 ꢁ)
4.57 m (15 ꢁ)
44 Typ.
Straight
M12 x 1
MQD9-430
9.14 m (30 ꢁ)
ø 14.5
2
3
1
4
MQD9-406RA
MQD9-415RA
1.83 m (6 ꢁ)
32 Typ.
[1.26"]
4.57 m (15 ꢁ)
30 Typ.
[1.18"]
1 = Brown
2 = Blue
Right-Angle
MQD9-430RA
9.14 m (30 ꢁ)
M12 x 1
ø 14.5 [0.57"]
Replacement Lenses
Replacement Lens Assemblies
Models
UC-45L
UC-45LP
UC-45D
UC-45F
UC-45FP
UC-45C
UC-45C4
Descripꢀon
Replacement lens for E, R, DL and LV models
Replacement lens for LP
Replacement lens for D
Replacement lens for F and FV
Replacement lens for FP
Replacement lens for CV
Replacement lens for CV4
Q45 Series lens assemblies are field-replaceable.
Brackets
Mounꢀng Brackets
SMB30C
56
SMB30SC
67
•
Swivel bracket with 30 mm
•
•
•
30 mm split clamp, black PBT
bracket
Stainless steel mounꢀng
hardware included
Mounꢀng hole for 30 mm
B
mounꢀng hole for sensor
A
B
•
•
Black reinforced thermoplasꢀc
polyester
Stainless steel mounꢀng and
swivel locking hardware
included
66
13
58
sensor
29
A
Hole center spacing: A=ø 45
Hole size: B=ø 27.2
Hole center spacing: A=ø 50.8
Hole size: A=ø 7.0, B=ø 30.0
P/N 38343 Rev. K
www.bannerengineering.com - Tel: +1-763-544-3164
9
Q45AD9 NAMUR Series Sensor
Mounꢀng Brackets
SMB30MM
SMB30UR
•
12-ga. stainless steel bracket
•
2-piece universal swivel bracket
for limit-switch style sensors
300 series stainless steel
Stainless steel swivel locking
hardware included
57
70
with curved mounꢀng slots for
versaꢀle orientaꢀon
•
•
C
•
•
Clearance for M6 (¼ in)
57
hardware
B
Mounꢀng hole for 30 mm
sensor
Hole center spacing: A to B=31.8, B to C=19.0, A to C=50.8, D=50.8
Hole size: C=6.9x32, D=73.0x6.9
A
Hole center spacing: A = 51, A to B = 25.4
Hole size: A = 42.6 x 7, B = ø 6.4, C = ø 30.1
Repairs and Translaꢀons
Obtain assistance with product repairs by contacꢀng your local Banner Engineering Corp distributor or by calling Banner directly at (763)
544-3164. Access literature translated into your naꢀve language on the Banner website at www.bannerengineering.com or contact
Banner directly at (763) 544-3164.
Para reparaciones de productos, por favor contacte a su distribuidor local de Banner Engineering o llame a Banner directamente al (763)
544-3164. Vea la literatura traducida en su idioma en el siꢀo web Banner en www.bannerengineering.com o comuníquese con Banner
directamente al (763) 544-3164.
Pour vous aider lors de la réparaꢀon de produits, contactez votre distributeur Banner local our appelez directement Banner au (763)
544-3164. La documentaꢀon traduite dans votre langue est disponible sur le site internet de Banner www.bannerengineering.com ou
contactez directement Banner au (763) 544-3164.
Banner Engineering Corp. Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or
replace, free of charge, any product of its manufacture which, at the ꢀme it is returned to the factory, is found to have been defecꢀve during the warranty period. This warranty does not cover
damage or liability for misuse, abuse, or the improper applicaꢀon or installaꢀon of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discreꢀon of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY
OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT
DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligaꢀons or liabiliꢀes relaꢀng to any product previously
manufactured by Banner Engineering Corp. Any misuse, abuse, or improper applicaꢀon or installaꢀon of this product or use of the product for personal protecꢀon applicaꢀons when the
product is idenꢀfied as not intended for such purposes will void the product warranty. Any modificaꢀons to this product without prior express approval by Banner Engineering Corp will void the
product warranꢀes. All specificaꢀons published in this document are subject to change; Banner reserves the right to modify product specificaꢀons or update documentaꢀon at any ꢀme.
Specificaꢀons and product informaꢀon in English supersede that which is provided in any other language. For the most recent version of any documentaꢀon, refer to:
www.bannerengineering.com.
©
Banner Engineering Corp. All rights reserved
相关型号: