Isolated and Regulated 40 WATT Modular DC/DC Converters  
FDC40 series  
Wide 2 : 1 Input Range  
High Efficiency  
Regulated Outputs  
1600V Isolation  
Full EMI Shielding  
PI Input Filter  
Unit measures 2.76”W x 3.94”L x 0.75”H  
Model Number  
Output Voltage  
Output Amps  
Input Range  
UL E193009;  
TUV R2054535;  
CB JPTUV-001393  
SINGLE OUTPUT  
FDC40-12S33  
FDC40-24S33  
FDC40-48S33  
FDC40-12S05  
FDC40-24S05  
FDC40-48S05  
FDC40-12S12  
FDC40-24S12  
FDC40-48S12  
FDC40-12S15  
FDC40-24S15  
FDC40-48S15  
3.3 VDC  
5 VDC  
10  
10  
10  
8
9-18 VDC  
18-36 VDC  
36-72 VDC  
9-18 VDC  
18-36 VDC  
36-72 VDC  
9-18 VDC  
18-36 VDC  
36-72 VDC  
9-18 VDC  
18-36 VDC  
36-72 VDC  
8
8
12 VDC  
15 VDC  
3.4  
3.4  
3.4  
2.7  
2.7  
2.7  
Order On-Line!  
astrodyne.com  
300 Myles Standish Blvd., Taunton, MA 02780  
WWW.ASTRODYNE.COM  
Ph: 1-800-823-8082  
Fax: 508-823-8181  
Isolated and Regulated 40 WATT Modular DC/DC Converters  
FDC40 series  
Wide 2 : 1 Input Range  
High Efficiency  
Regulated Outputs  
1600V Isolation  
Full EMI Shielding  
PI Input Filter  
Unit measures 2.76”W x 3.94”L x 0.75”H  
Model Number  
Output Voltage  
Output Amps  
Input Range  
UL E193009;  
TUV R2054535;  
CB JPTUV-001393  
DUAL OUTPUT  
FDC40-12D3305  
FDC40-24D3305  
FDC40-48D3305  
FDC40-12D05  
FDC40-24D05  
FDC40-48D05  
FDC40-12D12  
FDC40-24D12  
FDC40-48D12  
FDC40-12D15  
FDC40-24D15  
FDC40-48D15  
3.3 / 5 VDC  
+/-5 VDC  
4-Apr  
4-Apr  
4-Apr  
-7  
9-18 VDC  
18-36 VDC  
36-72 VDC  
9-18 VDC  
18-36 VDC  
36-72 VDC  
9-18 VDC  
18-36 VDC  
36-72 VDC  
9-18 VDC  
18-36 VDC  
36-72 VDC  
-7  
-7  
+/-12 VDC  
+/-15 VDC  
+/-1.8  
+/-1.8  
+/-1.8  
+/-1.4  
+/-1.4  
+/-1.4  
TRIPLE OUTPUT  
FDC40-12T0512  
FDC40-24T0512  
FDC40-48T0512  
FDC40-12T0515  
FDC40-24T0515  
FDC40-48T0515  
5, +/-12 VDC  
5, +/-15 VDC  
4, +/-0.85  
4, +/-0.85  
4, +/-0.85  
4, +/-0.68  
4, +/-0.68  
4, +/-0.68  
9-18 VDC  
18-36 VDC  
36-72 VDC  
9-18 VDC  
18-36 VDC  
36-72 VDC  
Order On-Line!  
astrodyne.com  
300 Myles Standish Blvd., Taunton, MA 02780  
WWW.ASTRODYNE.COM  
Ph: 1-800-823-8082  
Fax: 508-823-8181  
Isolated and Regulated 40 WATT Modular DC/DC Converters  
FDC40 series  
INPUT SPECIFICATIONS  
GENERAL SPECIFICATIONS  
Input Voltage Ranges:  
12 VDC Nominal  
24 VDC Nominal  
48 VDC Nominal  
Pi Type  
9-18 VDC  
18-36 VDC  
36-72 VDC  
On/Off Control  
(Ref to - Input pin)  
Logic “1”/Open=ON  
Logic “0”/GND=OFF  
1600VDC  
Input Filter  
Input-Out Isolation  
Isolation Resistance  
Efficiency  
10000 M Ohms  
82%, typ  
OUTPUT SPECIFICATIONS  
Switching Frequency  
185Khz, typ  
Voltage and Current  
Load Regulation  
See Selection Chart  
singles: +/-0.5%  
duals: +/-1%  
ENVIRONMENTAL SPECIFICATIONS  
triples: 5 V:+/-2%, Aux: +/-5%  
singles: +/-0.5%  
Oper. Temperature (Case)  
Storage Temperature  
Maximum Case Temp  
MTBF  
-25 to +85 DegC(see derate)  
Line Regulation  
-55 to +125 DegC *  
100 DegC *  
1.61 MHrs  
duals: +/-1%  
triples: 5V:+/-2%, Aux:+/-5%  
+/-0.02%/DegC  
Temperature Coefficient  
Ripple/Noise  
MIL-HDBK-217F TA=25C FL  
1% Pk-Pk of Vout, typ  
(singles/duals)  
Voltage Stability  
+/- 2%  
PHYSICAL SPECIFICATIONS  
(triples)  
5 V:+/-2%, Aux: +/-5%  
Short Circuit Protection  
Continuous, self-recovering  
Case Material  
Nickel-Coated Copper  
Non-Conductive Base  
Fully Encapsulated  
4.5 oz, (126g)  
Overvoltage Protection Threshold: 3.3V Output  
3.9Volts  
6.2Volts  
15Volts  
18Volts  
5V Output  
12V Output  
15V Output  
Construction  
Weight  
EFFICIENCY CURVES  
FDC40-48S05  
FDC40-48S05  
Efficiency VS Input Voltage  
Efficiency VS Output load  
90  
90  
89  
88  
86  
84  
82  
80  
70  
60  
50  
45  
89  
88  
87  
86  
85  
84  
83  
82  
81  
80  
36 40 45 50 55 60 65 70 75  
1
2
3
4
5
6
7
8
0.5  
INPUT VOLTAGE (V)  
OUTPUT LOAD (A)  
All specifications are typical at nominal input, full load, and 25DegC unless  
otherwise noted  
Astrodyne products are not authorized or warranteed for use  
as critical components in life support systems, equipment used  
in hazardous environments, nuclear controls systems, or other  
mission-critical applications.  
* These are stress ratings. Exposure of the devices to any of these conditions  
may adversely affect long term reliability. Proper operation under conditions  
other than the standard operating conditions is neither warranteed nor implied.  
300 Myles Standish Blvd., Taunton, MA 02780  
WWW.ASTRODYNE.COM  
Ph: 1-800-823-8082  
Fax: 508-823-8181  
Isolated and Regulated 40 WATT Modular DC/DC Converters  
FDC40 series  
MECHANICAL DIMENSIONS  
EXTERNAL OUTPUT TRIMMING  
2.60 (66.0)  
Output can be externally trimmed by  
using the method shown below.  
0.40  
0.40  
0.40  
(10.2)  
0.60 (15.2) (10.2) (10.2)  
0.70 (17.8)  
(
[
) for dual output trim  
] for triple output trim  
{
} XXD3305 only trim 3.3V/5V  
TRIM UP  
TRIM DOWN  
1
2
3
4
7 (7) [9] {6}  
6 (8) [10] {8}  
RU  
RD  
6 (8) [10] {8}  
5 (5) [8] {5}  
Bottom  
View  
Pin # Single  
Dual  
Triple  
1
2
3
4
5
6
7
8
9
10  
Ctrl  
Ctrl  
Ctrl  
+ Vin  
- Vin  
+ Vin  
- Vin  
Sync  
+ Vin  
- Vin  
Sync  
Sync  
5
6
7
8
9
10  
+ OutS  
Trim  
+ Vout or 3.3 out  
Com  
+ Vout  
Com  
0.50  
(12.7)  
0.40  
0.40  
0.40  
0.32  
(8.0)  
- OutS  
+ Vout  
- Vout  
No Pin  
- Vout or 5 out  
Trim  
- Vout  
+5 Out  
-5 Out  
Trim  
0.32 (7.6)  
0.32 (7.6)  
(10.2) (10.2) (10.2)  
No Pin  
No Pin  
1. All dimensions in Inches (mm)  
2. Pin pitch tolerance 0.014 (0.35)  
OUTPUT DERATING CURVE  
FDC40-48S05 Derating Curve  
100  
75  
50  
25  
0
Nature convection  
-40 -25 -10  
0
50  
60  
70  
80  
90  
100  
AMBIENT TEMPERATURE (ºC)  
300 Myles Standish Blvd., Taunton, MA 02780  
Ph: 1-800-823-8082 Fax: 508-823-8181  
WWW.ASTRODYNE.COM  
Isolated and Regulated 40 WATT Modular DC/DC Converters  
FDC40 series  
APPLICATION OF SYNCHRONIZATION  
1. The unit is capable of external synchronization from an independent  
time base with a switching rate between 200kHz and 215kHz  
2. The amplitude of the synchronizing pulse train is TTL compatible  
3. The duty cycle of the CLK should be 20% high and 80% low  
4. Synchronization is referenced to negative input (-Vin)  
Converter 1  
2
+ Vin  
+
4
Sync  
3
- Vin  
-
Converter 2  
2
+
4
Sync  
ON/OFF Control application  
3
Converter  
-
2
+ Vin  
+
CLK  
1
3
CTRL  
CLK Signal  
80%  
2N7000  
- Vin  
-
ON/OFF Control  
20%  
300 Myles Standish Blvd., Taunton, MA 02780  
Ph: 1-800-823-8082 Fax: 508-823-8181  
WWW.ASTRODYNE.COM  

相关型号:

FDC40-12S15

Isolated and Regulated 40 WATT Modular DC/DC Converters
ASTRODYNE

FDC40-12S15

SIINGLE,, DUAL AND TRIIPLE OUTPUT,, HIIGH DENSIITY 40 WATTS DC//DC CONVERTERS
VOLGEN

FDC40-12S33

Isolated and Regulated 40 WATT Modular DC/DC Converters
ASTRODYNE

FDC40-12S33

SIINGLE,, DUAL AND TRIIPLE OUTPUT,, HIIGH DENSIITY 40 WATTS DC//DC CONVERTERS
VOLGEN

FDC40-12T0512

Isolated and Regulated 40 WATT Modular DC/DC Converters
ASTRODYNE

FDC40-12T0515

Isolated and Regulated 40 WATT Modular DC/DC Converters
ASTRODYNE

FDC40-24D05

Isolated and Regulated 40 WATT Modular DC/DC Converters
ASTRODYNE

FDC40-24D05

SIINGLE,, DUAL AND TRIIPLE OUTPUT,, HIIGH DENSIITY 40 WATTS DC//DC CONVERTERS
VOLGEN

FDC40-24D12

Isolated and Regulated 40 WATT Modular DC/DC Converters
ASTRODYNE

FDC40-24D12

SIINGLE,, DUAL AND TRIIPLE OUTPUT,, HIIGH DENSIITY 40 WATTS DC//DC CONVERTERS
VOLGEN

FDC40-24D15

Isolated and Regulated 40 WATT Modular DC/DC Converters
ASTRODYNE

FDC40-24D15

SIINGLE,, DUAL AND TRIIPLE OUTPUT,, HIIGH DENSIITY 40 WATTS DC//DC CONVERTERS
VOLGEN