ASL365-48 [ASTRODYNE]

365W Ultra High Density PFC Switcher with 12V aux;
ASL365-48
型号: ASL365-48
厂家: ASTRODYNE CORPORATION    ASTRODYNE CORPORATION
描述:

365W Ultra High Density PFC Switcher with 12V aux

功率因数校正
文件: 总3页 (文件大小:1296K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
365W Ultra High Density PFC Switcher with 12V aux  
ASL365 series  
Single Outputs with 12V Auxillary  
Universal 90 to 264VAC Input  
5VDC to 48VDC Outputs  
3,000VAC Input to Output Isolation  
Short Circuit Protection  
Full Safety Approvals  
Model Number  
V1  
I1 Air Flow Convection / 200LFM I2 (12V aux.)  
ASL365-5  
ASL365-12  
ASL365-24  
ASL365-48  
5VDC  
25 / 40A  
0.5 max.  
12VDC  
24VDC  
48VDC  
16.6 / 31.25A  
8.4 / 15.62A  
4.2 / 7.81A  
0.5 max.  
0.5 max.  
0.5 max.  
Notes:  
These products are 0- Full Load operation  
Convection Cooling - Total Power not to exceed the rated output power of 200W convection cool for 12, 24 and 48V  
models or 125W for 5V model.  
200 LFM - Total Power not to exceed the rated output power of 375W forced air for 12, 24 and 48V models or 200W  
for 5V model.  
ASTRODYNE USA: 1-800-823-8082  
ASTRODYNE PACIFIC: 886-2-26983458  
WWW.ASTRODYNE.COM  
365W Ultra High Density PFC Switcher with 12V aux  
ASL365 series  
INPUT SPECIFICATIONS  
ENVIRONMENTAL SPECIFICATIONS  
Input Voltage Range (AC / DC) 90-264 / 170-370  
Oper. Temperature  
-20 to +50°C FL Derate Linearly to  
50% Load at 70°C *  
Input Current  
4A @ 90VAC  
Inrush Current  
230VAC Cold Start  
90% @ Full Load  
47-63Hz  
Cooling  
200LFM >200W O/P Power  
95% Non Condensing  
Efficiency  
Relative Humidity  
Storage Temperature  
Operating Altitude  
Shock  
Input Frequency  
Power Factor (90VAC)  
Input Fuse  
-20 to +85°C *  
3000m  
0.98% min.  
2A Internal Line & Neutral  
80VAC Auto Recover  
110/200uA  
30G, Half Sine, 6 Axis  
Under Voltage Lockout  
Leakage Current (115/230 I/P)  
Vibration  
2G, 5-500Hz, 3 Axis  
MTBF  
Convection Cooled: 100,000Hrs  
Air Flow (200 CFM): 300,000 Hrs  
EN55022, EN60601-1-2 Class B  
4dB Margin  
EMC  
Conducted EMI  
OUTPUT SPECIFICATIONS  
Radiated EMI  
Voltage Fluctuation  
ESD  
EN55022, Class B, 4dB Margin  
EN61000-3-3  
Setpoint Accuracy  
Voltage Adjust  
+/-1% Main Output V1  
5% Main Output V1  
EN61000-4-2, 8KV Air, 6KV Contact  
EN61000-4-3, 3V/m, 80-2500MHz  
1kHz/2Hz 80% AM Modulation  
Dwell Time is 3S for 2Hz Modulation  
Dwell Time is 1S for 1Hz Modulation  
EN61000-4-4, 2kV on AC and DC  
5kHz repetition 1kV on I/O  
EN61000-4-5, 2kV CM, 1kV DM  
(min 5 surges at each phase angle)  
Load Regulation  
Line Regulation  
+/-1% V1; +/-5% V2 (12V aux,)  
+/-0.1% 90-264VAC  
Radiated Field  
Cross Regulation  
Transient Response  
(50% Load Change)  
+/-1% V1; +/-15% V2 (12V aux,)  
10% Recover within 1mS  
EFT  
Set-Up/Rise/Hold-Up (HL; Min Load)  
1S/10mS/16mS  
+/-0.25mV/°C  
Ripple/Noise (pk-pk, 20Mhz BW) 1% of Output; +/-2% V2 (12V aux,)  
Surge  
Temperature Coefficient  
Conducted RF Immunity  
Overvoltage Protection  
Redundant Protection for Open  
Feedback *  
EN61000-4-6, 3Vrms, 0.15-80MHz  
1kHz/2Hz 80% AM Modulation  
OverCurrent Protection  
110-130% Auto Recover*  
Magnetic Field Immunity  
Dips & Interruptions  
Short Circuit and Over Temp Protection  
Auto Recovery *  
EN61000-4-8, 50 and 60 Hz, 3A/m  
EN61000-4-11  
Remote Sense  
0.5V min (5V Only)  
Dip to 40% for 5 cycles (100mS)  
Dip to 70% for 25 cycles (500mS)  
Dropout to 5% for 10mS  
Inerrupts>95% for 5S  
GENERAL SPECIFICATIONS  
I/P-O/P Isolation  
3000VAC for 1 Minute  
1500VAC for 1 Minute  
100VDC for 1 Minute  
500VAC for 1 Minute  
Safety Standards  
Size  
EN60950, IEC60950, UL/cUL 60950  
3” x 5” x 1.33”  
I/P-Ground Isolation  
O/P-O/P Isolation  
O/P-Ground Isolation  
Astrodyne products are not authorized or warranteed for use  
as critical components in life support systems, equipment used  
in hazardous environments, nuclear controls systems, or other  
mission-critical applications.  
* These are stress ratings. Exposure of the devices to any of these conditions  
may adversely affect long term reliability. Proper operation under conditions  
other than the standard operating conditions is neither warranteed nor implied.  
All specifications are typical at nominal input, full load, and 25DegC unless  
otherwise noted  
ASTRODYNE USA: 1-800-823-8082  
WWW.ASTRODYNE.COM  
ASTRODYNE PACIFIC: 886-2-26983458  
365W Ultra High Density PFC Switcher with 12V aux  
ASL365 series  
Mechanical Specification  
ASTRODYNE USA: 1-800-823-8082  
WWW.ASTRODYNE.COM  
ASTRODYNE PACIFIC: 886-2-26983458  

相关型号:

ASL365-5

365W Ultra High Density PFC Switcher with 12V aux
ASTRODYNE

ASL380

Wideband Linear Amplifier MMIC
ASB

ASL390

Wideband Linear Amplifier MMIC
ASB

ASL40

40W Ultraminiature Open Frame Switching Power Supplies
ASTRODYNE

ASL40-12

40W Ultraminiature Open Frame Switching Power Supplies
ASTRODYNE

ASL40-12A

40W Ultraminiature Open Frame Switching Power Supplies
ASTRODYNE

ASL40-15

40W Ultraminiature Open Frame Switching Power Supplies
ASTRODYNE

ASL40-15A

40W Ultraminiature Open Frame Switching Power Supplies
ASTRODYNE

ASL40-24

40W Ultraminiature Open Frame Switching Power Supplies
ASTRODYNE

ASL40-24A

40W Ultraminiature Open Frame Switching Power Supplies
ASTRODYNE

ASL40-36

40W Ultraminiature Open Frame Switching Power Supplies
ASTRODYNE

ASL40-36A

40W Ultraminiature Open Frame Switching Power Supplies