LPS41 [ASTEC]
40 Watts; 40瓦Embedded Power for
Business-Critical Continuity
Rev. 04.13.06
LPS40 Series
1 of 3
LPS40 Series
40 Watts
RoHS
Total Power:
40-55 Watts
Input Voltage: 85-264 VAC
120-300 VDC
# of Outputs:
Single
Electrical Specifications
Input
Special Features
• Universal input
• 3" x 5" footprint
• Less than 1U high
• Remote sense
• Terminal block option (-T)
• Built-in EMI filter
Input range
Frequency
Inrush current
Input current
Efficiency
85-264 VAC; 120-300 VDC
47-440 Hz
<18A peak @ 115VAC; <36A peak @ 230VAC, cold start @ 25°C
1A max. (RMS) @ 115VAC
70% typical at full load
EMI filter
FCC Class B conducted; CISPR 22 Class B conducted;
EN55022 Class B conducted; VDE 0878 PT3 class B conducted
• Low output ripple
<0.5 mA @ 50/60 Hz, 264 VAC input
• Adjustable output
• Overvoltage protection
• Overload protection
• 110 KHz switching frequency
• LPX40 enclosure kit available
Safety ground
leakage current
Output
Maximum power
Adjustment range
Hold-up time
40W for convection; 55W with 30CFM forced air
-5, +10% minimum
20ms @ 40W load, 115VAC nominal line
Short circuit protection on all outputs
Case overload protected @ 110-145% above peak rating
Overload protection
Overvoltage protection
Remote sense
5V output; 5.7 to 6.7VDC. Other outputs 10% to 25% above
nominal output
Compensates for 0.5 V lead drop minimum
Will operate without remote sense connected
Reverse connection protected
Safety
UL
UL1950 E132002
CSA 22.2-234 Level 3
LR53982C
CSA
NEMKO EN 60950/EMKO-TUE
P94100375 (74-sec) 203
CB
Certificate and report
1119, 1125, 1126, 1127
CE Mark (LVD)
Embedded Power for
Business-Critical Continuity
Rev. 04.13.06
LPS40 Series
2 of 3
Environmental Specifications
Operating temperature: 0° to 50°C ambient. Derate each output 2.5% per degree from
50° to 70°C, -20°C start up.
Storage temperature:
-40°C to +85°C
Temperature coefficient:
0.4% per °C
Electromagnetic
susceptibility:
Humidity:
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Operating; non-condensing 5% to 95% RH
Vibration:
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at
four major resonances 0.75G peak 5Hz to 500Hz, operational
>550,000 hours at full load and 25°C ambient conditions
MTBF demonstrated:
Ordering Information
Maximum Load
Ripple P/P
Output Minimum Maximum Load with with 30CFM
Model
1
2
3
Number Voltage Load
Convection Cooling forced Air
Peak Load Regulation (PARD)
LPS41(-T) 3.3V
LPS42(-T) 5V
LPS43(-T) 12V
LPS44(-T) 15V
LPS45(-T) 24V
LPS48(-T) 48V
0A
0A
0A
0A
0A
0A
8A
11A
12A
12A
5A
2%
2%
2%
2%
2%
2%
50 mV
50 mV
8A
11A
3.3A
2.6A
1.7A
0.9A
4.5A
3.6A
2.3A
1.2A
120 mV
150mV
240mV
480 mV
4A
2.5A
1.3A
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and
load ranges.
4. (-T) indicates Terminal Block option for input and output (instead of Molex type)
Power Derating Curve
55W
30 CFM Forced Air Cooling
40W
30W
Output
Power
(Watts)
27.5W
20W
Natural
Convection
Cooling
20W
10W
0W
0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C
TA – Ambient Temperature – °C
Embedded Power for
Business-Critical Continuity
Rev. 04.13.06
LPS40 Series
3 of 3
Mechanical Drawing
Astec Power
5.00"
(127)
5810 Van Allen Way
Carlsbad, CA 92008
0.22"
(5.6)
4.55"
(115.6)
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Technical Support: +1 888 41 ASTEC
or +1 407 241 2752
GND
M1
Remote Sense
Connector
Voltage
M2
SK201
_
+
Adj. Pot
3.00"
(76.2)
SK 2
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
1
2
3
4
5
6
2.55"
(64.8)
SK 1
N
L
3
1
Units 2111-2116, Level 21
Tower 1, Metroplaza
223, Hing Fong Road
Kwai Fong, New Territories
Hong Kong
0.15" (4)
DIA (4 places)
Telephone: +852 2437 9662
Facsimile: +852 2402 4426
For global contact, visit:
www.astecpower.com
technicalsupport@astec.com
1.14"
(29)
While every precaution has been taken to ensure
accuracy and completeness in this literature, Astec
Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
0.12"
(3)
Pin Assignments
Printed in USA
Connector LPS41
LPS42
LPS43
Line
LPS44
Line
LPS45
Line
LPS48
Line
SK1-1
SK1-3
Line
Line
Neutral Neutral Neutral Neutral Neutral Neutral
Emerson Network Power.
The global leader in enabling
business-critical continuity.
SK2-1
SK2- 2
SK2- 3
SK2-4
SK2-5
SK2-6
+3.3V
+3.3V
+3.3V
+5V
+5V
+5V
+12V
+12V
+12V
+15V
+15V
+15V
+24V
+24V
+24V
+48V
+48V
+48V
Common Common Common Common Common Common
Common Common Common Common Common Common
Common Common Common Common Common Common
AC Power
Connectivity
DC Power
SK201-1 +Sense +Sense +Sense +Sense +Sense +Sense
SK201-2 -Sense -Sense -Sense -Sense -Sense -Sense
Mating Connectors
Embedded Power
AC Input:
Molex 09-50-8031 (USA) Not required for (-T) option
09-91-0300 (UK)
Inbound Power
PINS: 08-52-0113
Integrated Cabinet Solutions
Outside Plant
DC Outputs:
Molex 09-50-8061 (USA) Not required for (-T) option
09-91-0600 (UK)
PINS: 08-52-0113
Remote Sense: Molex 22-01-2025
PINS: 08-52-0123
Precision Cooling
Astec Connector Kit #70-841-006, includes all of the above
Site Monitoring and Services
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is 0.02" ( 0.5mm)
EmersonNetworkPower. com
3. Mounting holes M1 and M2 should be grounded for EMI purposes.
4. Mounting hole M1 is safety ground connection.
5. Specifications are for convection rating at factory settings at 115 VAC
input, 25°C unless otherwise stated.
6. Warranty: 1 year
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2006 Emerson Electric Co.
7. Weight: 0.5lbs/0.23kg