3554 [ASM-SENSOR]

BATTERY HiTESTER; 电池测试仪
3554
型号: 3554
厂家: ASM GMBH    ASM GMBH
描述:

BATTERY HiTESTER
电池测试仪

电池 测试
文件: 总4页 (文件大小:1936K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
BATTERY HiTESTER 3554  
Field Measuring Instruments  
Get a Complete Diagnosis of UPS Batteries  
with a Single Device  
Auto-hold and Auto-data storage  
resistance against noise  
4800 sets of data  
e  
ngeable probe tip  
WIDE  
60V RANGE  
Ideal for UPS  
Backup Batteries  
The New Standard for Assessing  
Deterioration of Lead-acid Batteries  
Repeated recharging of a secondary battery can lead to  
battery deterioration and increase its internal resistance.  
Problems can intensify when there is a short-circuit in  
the internal cell leading to voltage drop, overheating  
and complete battery malfunction. Worst of all, these  
problems can cause life-threatening fires and other  
accidents.  
2
HANDS FREE Data Capture Allows You to Focus on the Testing  
Toggle  
between 4  
Automatically save data as  
soon as reading is stabilized  
different  
AUTO HOLD & AUTO MEMO  
ways to save  
data  
TEST & SAVE  
Press the HOLD  
then MEMO keys  
whenever you need  
AUTO MEMO  
Instantaneously save  
to save data  
measurement data with  
one touch using the  
R e m o t e C o n t r o l  
Switch 9466 saddled  
to the test lead  
Save up  
to 4800 Sets  
of Battery  
Data  
Check stabilized measurement value before  
saving with the Remote Control Switch 9466  
AUTO HOLD  
Quickly Download Data to a PC via  
USB Interface - Effortlessly Manage Using  
Bundled Software  
Store and  
edit up to 200  
The hassle-free measurement process is extended to  
sets of  
comparator  
data management and processing using the bundled  
data management software. All 4800 sets of data can  
settings  
be uploaded to the PC quickly and effortlessly via a  
USB cable, and displayed neatly in table format. Edit  
comparator tables and send them back to the 3554.  
Pencil  
and  
Paper  
USB  
Edit and Send  
Comparator Settings  
NotRequired  
Download:  
Automatically clear  
data from the 3554  
Data Memory Number  
Range  
Resistance value  
Resistance limits  
Voltage value  
Voltage limit  
Temperature  
Judgement  
Download Data  
to a Spreadsheet  
Date & time  
3
Tough Against Noise Plus Wide 60V Range  
Trying to measure UPS backup batteries while they  
Three-rank rating of battery state:  
are still being used naturally brings about noise com-  
ing from the battery's inverter or rectifying circuit.  
The enhanced measurement current in the 3554  
plus fortified circuit design, added with the Averaging  
Function to handle batteries that have fluctuating  
measurement values no matter how steady you hold  
the probe makes the battery tester extra resistant  
against the adverse effects of noise.  
Pass, Warning or Fail  
Assessment is based on a 6-way combination of comparisons against upper and lower  
resistance limits and a voltage threshold. Immediately see the judgement result on the  
bright LCD and beep on your choice of PASS or WARNING/FAIL.  
Resistance  
Low  
In Range  
High  
VOLTAGE  
High  
Low  
Pass  
Warning  
Warning  
Warning  
Fail  
Fail  
Voltage  
threshold value  
First resistance limit  
Second resistance limit  
Common battery cells:  
0 to 12V DC  
10 Hours of  
Continuous  
Operation  
Save time  
Fork lifts and electric  
vehicles: 48V DC  
and money  
with an  
60VDC maximum  
between terminals  
uninterrupted  
workflow  
Wide Selection of Tough and  
The standard Pin Type Leads 9465-10 with the single test pin on each lead has been fortified to  
withstand even the toughest use, while a new dual-axis mechanism incorporated in the new Pin Type  
Lead 9772 allows the TWO pins in each test lead to move independently. Just in case of breakage,  
the pins on both the 9465-10 and the 9772 can be replaced easily on site.  
Versatile Test Probes  
φ 2.9  
Maximum jaw  
diameter:φ 15mm  
Strengthened  
Test Pin  
φ 1.27  
φ 2.7  
Clip Type Lead with 1.7m between connector and  
Temperature Sensor junction  
φ 1.8  
9460  
25cm between junction and  
probe tip  
Pin Type Lead 9465-10  
2.5  
4.3  
(standard accessory)  
1.6m between connector  
and junction  
Dual Pins/  
Dual Axes  
Large Clip Type  
Leads 9467  
25cm between junction and  
probe tip  
Pin Type Lead 9772  
85cm between connector  
and junction  
25cm between junction and  
probe tip  
Maximum jaw diameter:  
φ29mm  
1.6m between connector  
and junction  
25cm between junction and  
probe tip  
φ 29 mm  
Remote Control  
Switch 9466  
2m between connector and  
junction  
Diagonal probing  
is no longer  
a problem.  
Zero Adjustment Board 9454  
(standard accessory)  
9465-10  
9772  
The Advantages of 4-Terminal Measurement  
(Pin to Sheath: 0.65mm) (Pin to Pin: 2.5mm)  
The Quality of Your Test Lead CAN Make a Difference  
When measuring certain batteries such as lead-  
acid cells, the resulting measurement value may differ  
depending on the test leads used to conduct the  
measurement. This difference is due to the shape  
of the probe tip as well as the dimensions of the  
4-terminal test leads used for measurement. However,  
despite a difference in value given by different test  
leads, it is safe to assume that each specific value  
reflects the correct value obtainable by the respective  
test leads.  
and dimensions in order to maintain measurement  
consistency.  
The difference in the measurement values  
obtained by different test leads is a physical  
phenomenon caused by the difference in distance  
between the SOURCE and SENSE pins of the test  
leads. This is more significant when the battery  
terminal contains a resistance higher than the internal  
resistance of the battery under test. The figure on  
the right demonstrates how even minute physical  
differences between the SOURCE and SENSE pins for  
two types of test leads can affect the detected voltage  
level of the battery.  
+
-
+
-
Battery  
Battery  
Equivalent electric  
potential curve  
Electric potential  
slope  
Based on this principle, when diagnosing  
battery deterioration in a time series, it is particularly  
important to use test leads having the same tip shape  
A
B
V(Detected Voltage): A>B  
4
Specifications  
Dimensions  
and mass  
: Approx.192W x 121H x 55D mm, 790 g (including batteries)  
Basic Specifications  
Measurement items  
:
Resistance (AC four-terminal method), voltage,  
temperature (platinum temperature sensor, only when  
using 9460 leads)  
Accessories  
: PIN TYPE LEAD 9465-10 x 1, USB cable x 1, Application  
Software CD x 1, Strap x 1, Carrying case x 1, Zero adjustment  
board x 1, LR6 alkaline batteries x 8, Fuse x 1  
Display  
:
LCD  
LCD All Segments  
Displayed  
The standard 3554  
Package comes bundled  
with one Pin type Lead  
9465-10, one USB Cable,  
data management PC  
software, tough carrying  
case, zero-adjustment  
board, eight AA batteries,  
and one spare fuse.  
Sampling rate  
:
:
:
:
Once per second  
OFF, 4, 8, or 16 times  
[OF] is displayed  
[----] is displayed  
Averaging Function  
Input overflow  
Constant current fault  
detection  
Open-circuit terminal  
voltage  
:
:
:
5 VMax  
Auto power off  
Auto power off after 10 minutes unless during data  
transmission  
Functions  
HOLD  
:
(1) Pressing the HOLD key  
Comparator Settings  
First and second resistance limits, and lower voltage limit  
(2) Inputting signals to the EXT.HOLD/MEMO terminal  
(3) Stabilizing measured values (when the auto-hold feature is on)  
While the measured values are being held, pressing MEMO key  
will save them to internal memory.  
When the auto-memory feature is on, measured values will be  
saved to the instrument's internal memory when held.  
Saved items: Date, time, resistance value, voltage value,  
temperature, comparator setting values, and comparator  
judgement. Maximum storable data: 4800 sets.  
Memory structure: 400 data sets per unit (12 units)  
Read stored data on instrument or with PC application  
USB  
Number of Comparator : 200 Sets  
Settings  
Data Storage  
:
Comparator Output  
:
:
:
:
LCD display of PASS, WARNING, or FAIL. Select  
beeper to sound on PASS/WARNING or FAIL.  
Operating temperature  
and humidity  
0 to 40°C (32°F to 104°F), 80% rh or less (no  
condensation)  
Absolute maximum  
input voltage  
60V DC, No AC input allowed  
Withstand voltage  
Between input terminals and output terminals ( including  
EXT. HOLD/MEMO, and USB terminals): 1.5 kV AC rms  
for 15 seconds  
Reading data  
PC Interface  
PC Software  
Application  
:
:
:
Maximum rated power  
consumption  
:
:
:
2 VA  
Windows compatible, using USB interface  
PC to 3554: transfer comparator tables edited on Excel, delete  
data from 3554, initialize the 3554, make clock settings.  
3554 to PC: transfer data stored in memory (save files on PC in  
CSV format)  
Continuous operating  
time  
Approx. 10 hours (When using alkaline batteries; may  
vary depending on conditions of use)  
Power supply  
AA (LR6) Alkaline Batteries x 8  
Measurement Accuracy (Guaranteed Accuracy Period: 1 Year)  
Guaranteed Accuracy  
Conditions  
: 23°C± 5°C (73°F± 9°F), non-condensating, after zero-  
adjustment, warm-up time not required  
Voltage Measurement  
Temperature coefficient  
:
±0.005 %rdg.±0.5 dgt./°C  
Resistance Measurement  
Range  
6 V  
Max. display  
Resolution  
1 mV  
Accuracy  
Temperature coefficient  
: ±0.01 %rdg.±0.8 dgt./°C  
±6.000 V  
±60.00 V  
Measurement current frequency : 1 kHz±30 Hz  
Measurement current reliability : ±10 %  
±0.08 %rdg.±6 dgt.  
60 V  
10 mV  
Range Max. display Resolution Measurement Current  
Accuracy  
Temperature Measurement  
Ω
3 m  
Ω
Ω
1µ  
3.100 m  
31.00m  
310.0 m  
150 mA  
150 mA  
15 mA  
±1.0 %rdg.±8 dgt.  
Ω
30 m  
Ω
Ω
10µ  
Measurement Range  
Resolution  
0.1°C  
Accuracy  
Ω
300 m  
Ω
Ω
100µ  
±0.8 %rdg.±6 dgt.  
10°C to 60°C  
±1.0°C  
Ω
Ω
Ω
1 m  
3
3.100  
1.5 mA  
Options  
To Our Valued Customers:  
Bundled with the standard 3554  
Pin-type Lead 9465-10  
Zero Adjustment Board 9454  
The thresholds for determining the pass/fail condition of a battery depends  
on the specifications and standards of the battery manufacturer, battery  
type, capacity, etc. It is important and necessary to always conduct  
battery testing against the internal resistance and terminal voltage of a  
new or reference battery. In some cases, it may be difficult to determine  
the deterioration state of sealed lead acid batteries which demonstrates  
smaller changes in internal resistance than traditional open type (liquid)  
lead-acid or alkaline batteries.  
Clip-type Lead with Temperature Sensor 9460  
Pin-type Lead 9772  
Remote Control Switch 9466  
Large Clip Type Lead 9467 (no CE mark)  
Tip Pin 9465-90 (to replace the tip on Model 9465-10)  
Tip Pin 9772-90 (to replace the tip on Model 9772)  
HIOKI (Shanghai) Sales & Trading Co., Ltd. :  
DISTRIBUTED BY  
1904 Shanghai Times Square Office, 93 Huai Hai Zhong  
Road, Shanghai, P.R.China POSTCODE: 200021  
TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360  
E-mail: info-sh@hioki.cn  
Guangzhou Rep. Office :  
HEAD OFFICE :  
Room 303, Profit Plaza,No.76, West Huangpu Road,  
Guangzhou, P.R.China POSTCODE: 510623  
TEL +86-20-38392673/2676 FAX +86-20-38392679  
E-mail: info-gz@hioki.cn  
81 Koizumi, Ueda, Nagano, 386-1192, Japan  
TEL +81-268-28-0562 / FAX +81-268-28-0568  
E-mail: os-com@hioki.co.jp  
Beijing Rep. Office :  
HIOKI USA CORPORATION :  
A-2602 Freetown, 58 Dong San Huan Nan Road, Beijing,  
P.R.China POSTCODE: 100022  
6 Corporate Drive, Cranbury, NJ 08512 USA  
TEL +1-609-409-9109 / FAX +1-609-409-9108  
E-mail: hioki@hiokiusa.com  
TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090  
E-mail: info-bj@hioki.cn  
All information correct as of May. 31, 2007. All specifications are subject to change without notice.  
3554E4-75E-03P Printed in Japan  

相关型号:

355402

RAST-2.5-Steckverbinder, Raster 2,5/5,0 mm
LUMBERG

355403

RAST-2.5-Steckverbinder, Raster 2,5/5,0 mm
LUMBERG

355403K00

Board Connector, 3 Contact(s), 1 Row(s), Male, Right Angle, 0.098 inch Pitch, Solder Terminal, Polarized Lck, Receptacle
LUMBERG

355404

RAST-2.5-Steckverbinder, Raster 2,5/5,0 mm
LUMBERG

355405

RAST-2.5-Steckverbinder, Raster 2,5/5,0 mm
LUMBERG

355405K00

Board Connector, 5 Contact(s), 1 Row(s), Male, Right Angle, 0.098 inch Pitch, Solder Terminal, Polarized Lck, Receptacle
LUMBERG

355406

RAST-2.5-Steckverbinder, Raster 2,5/5,0 mm
LUMBERG

355406K00

Board Connector, 6 Contact(s), 1 Row(s), Male, Right Angle, 0.098 inch Pitch, Solder Terminal, Polarized Lck, Receptacle
LUMBERG

355407

RAST-2.5-Steckverbinder, Raster 2,5/5,0 mm
LUMBERG

355408

RAST-2.5-Steckverbinder, Raster 2,5/5,0 mm
LUMBERG

355408K00

Board Connector, 8 Contact(s), 1 Row(s), Male, Right Angle, 0.098 inch Pitch, Solder Terminal, Polarized Lck, Receptacle
LUMBERG

355409

RAST-2.5-Steckverbinder, Raster 2,5/5,0 mm
LUMBERG