3239 [ASM-SENSOR]

DIGITAL HiTESTER; 数字测试仪
3239
型号: 3239
厂家: ASM GMBH    ASM GMBH
描述:

DIGITAL HiTESTER
数字测试仪

测试
文件: 总8页 (文件大小:3781K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DIGITAL HiTESTER  
(4-terminal Ω function)  
3239  
(Advanced model)  
3238  
(Economically priced)  
Field measuring instruments  
3237  
Outstanding performance for production lines with a sampling rate of 3.3 ms  
High-speed DMM  
The DIGITAL HiTESTERs 3237, 3238, and 3239 can perform 3.3 ms high-speed sampling, and come  
equipped with a comparator, external input and output, and an RS-232C interface. These three high-  
performance DMMs can be used not only in laboratories, but in production lines that require the minimal  
tact time.  
The 3237 is the basic model, and is equipped with the basic necessary functions. The 3238 is a high-  
precision, broadband model that also features current measurement terminals and a frequency measurement  
function. The 3239 includes the functions of the 3238 plus the 4-terminal resistance measurement function.  
All three units are designed with emphasis on measurement speed and safety.  
1
3.3 ms/sample  
High-speed Performance and Reliability  
Features  
Sampling speed Values in the ( ) show samples/second.  
Frequency  
50 Hz  
FAST*  
MEDIUM  
SLOW  
Samples at rates of up to 300 samples/sec. (3.3 ms/sample)  
Comparator function provides high-speed pass/fail evaluation  
Equipped with external input and output for sequence control  
3.3 ±1 ms (300) 130 ±5 ms (8) 1,040±50ms (1)  
3.3 ±1 ms (300) 108 ±5 ms (9) 1,080 ±50 ms (1)  
60 Hz  
* Approximately 55 ms required for self-calibration at 30-minute intervals.  
Does not apply at resistances higher than 2MΩ, or LPΩ higher than 200kΩ (see page 5).  
For the 3238 and 3239's frequency function gate time, see page 5.  
Usefull Save/Load function helps work go faster  
The 3237, 3238 and 3239 are equipped with a variety of  
True RMS value measurement  
Both the 3237 and 3238 use true RMS measurement  
for determination of distorted waveforms. In fact, HIOKI  
guarantees accuracy of the 3238 and 3239 for AC voltage of  
functions that help minimize tact time in production lines.  
For details, see page 2.  
10 Hz to 300 kHz, and AC current of 10 Hz to 30 kHz.  
Low power resistance measurement function  
prevents sample deterioration  
For specifications, see pages 5 and 6.  
The 3237, 3238 and 3239 use a low power Ω function to  
minimize sample degradation when measuring resistance.  
With this function, open terminal voltage never goes over 0.45  
Interface supports full remote operation  
Measurement can be automated by using a controller to operate  
the 3237 or 3238 through the GP-IB or RS-232C interface.  
V DC, and measurement current never surpasses 100 µA DC.  
For specifications, see pages 5 and 6.  
For details, see page 3.  
Select from 3 types of units  
The basic and economical  
The high-accuracy & multi-functional  
3237  
3238  
DC V basic accuracy: ±0.01% rdg.±2dgt.  
DC V basic accuracy: ±0.025% rdg.±2dgt.  
Includes frequency measurement for AC and DC A  
DC voltage  
For 4-terminal resistance measurement  
[5 ranges, 199.999 mV to 1000.00 V]  
3239  
AC voltage  
[4 ranges, 1999.99 mV to 700.00 V]  
DC V basic accuracy: ±0.01% rdg.±2dgt.  
Resistance  
All the functions of the 3238, plus 4-terminal Ω measurement  
[7 ranges, 199.999 Ω to 100.000 MΩ]  
2-terminal  
2-terminal  
Resistance LP  
[4 ranges, 1999.99 Ω to 1999.99 MΩ]  
Reliable resistance measurement  
Continuity check  
using the 4-terminal measurement method  
[A buzzer sounds when resistance is less than 50.00 Ω]  
Diode check  
Using 4-terminal resistance  
measurement, which is  
unaffected by variables  
such as measurement lead  
wiring resistance, the  
3239 displays outstanding  
resistance measurement  
capabilities.  
[Anode-cathode voltage in the 1999.99 mV range]  
Current measurement by  
clamp sensor  
AC/DC current  
[2 ranges, 199.999 mA and 1999.99 mA]  
Frequency  
[5 ranges, 99.9999 Hz to 300.000 kHz]  
Resistance  
[5 ranges,199.999 Ω to 1999.99 kΩ]  
4-terminal  
4-terminal  
Resistance LP  
[4 ranges,1999.99 Ω to 1999.99 MΩ]  
For clamp specifications, see page 4  
For DIGITAL HiTESTER specifications, see pages 5 and 6  
2
Minimizing tact time  
with sequence control  
High-speed comparator and external input/output  
Connector used: 57RE-40360-730B (D29) (DDK Ltd.)  
Conforming connector: ADS-HC360001-010 (Honda Tsushin Kogyo Co., Ltd.),  
RC30-36P (Hirose Electric Co., Ltd.) and other suitable connectors  
EXT.I/O  
Loading of saved settings from panel……LOAD 0 to 4  
Measurement start trigger input…………TRIG  
Measurement end signal output…………EOC  
Comparator output…………………………Hi, IN, Lo  
Internal power supply +5 V (max. 50 mA)……INT. DC V  
Internal GND………………………….………INT. GND  
Input type: CMOS level  
Signal voltage: Hi 3.8 V to 5.0 V, Lo 0 V (shorted) to 1.2 V  
Logic: Negative logic (Low active)  
Output type: Open collector  
Applied voltage: Max. 35 V DC, 50 mA  
Logic: Negative logic (Low active)  
With free running measurement  
Comparator with external output  
You can set the upper and lower limits, and display one of 3  
results: Hi, IN or Lo. In addition to LED and buzzer results,  
open collector output results are provided through the external  
input/output terminals.  
X: measurement value, H: Upper limit, L: Lower limit  
X > H…………………………Hi  
>
>
L
H
X
…………………IN  
L > X………………Lo  
Time  
MIN.  
TYP.  
MAX.  
Measurement trigger pulse width  
Trigger delay time  
T1  
T2  
500 µs  
W i t h e x t e r n a l c o n t r o l  
See below  
Sampling time  
using external  
control  
FAST  
MEDIUM  
SLOW  
See the table  
T3  
at the top right of page 1.  
Internal operation time  
2.0 ms  
500 µs  
T4  
T5  
From the end of measurement  
until the next trigger  
FAST  
for free running MEDIUM  
1.7 ms  
50 ms  
500 ms  
EOC Lo level time  
T6  
T7  
measurement  
SLOW  
FAST  
Sampling time  
See the table  
at the top right of page 1.  
for free running MEDIUM  
measurement  
SLOW  
Save/Load function for rapid response to various  
work situations  
A trigger delay designed for measurement safety  
The 3237, 3238 and 3239 are equipped with a trigger delay  
function that can be set to manual or automatic for the time  
period between trigger input and the display of the comparator  
result (see T2 in the figure above).  
You can save and recall a maximum of 30 DMM setting  
conditions for various range and comparator values.  
Manual settings: Designate periods in terms of millisecond intervals between 0.000 s and 9.999 s  
Automatic settings:  
FAST  
3 ms  
500 ms  
3 ms  
MEDIUM  
3 ms  
800 ms  
3 ms  
SLOW  
3 ms  
1.5 s  
DC V  
AC V  
Ω (200Ω to 200 kΩ)  
3 ms  
3
Automation of  
Line Inspection  
Available interfaces  
GP-IB (option –01 specifications)  
RS-232C (standard)  
Purpose: Remote control and measurement value output  
Standards conformance  
:
IEEE -488.1 1987  
Purpose: Remote control and measurement value output  
Reference standard  
Transmission speed  
(reference data)  
: IEEE –488.2 1987  
Transmission system  
Transmission speed  
Data bit length  
Stop bits  
: Asynchronous method Full duplex  
: 9600 bps (fixed)  
FAST MEDIUM SLOW  
1,m08s 0  
: 8 bits  
Transmission  
speed  
Power line frequency: 60Hz  
108 ms  
7.0 ms  
: 1  
TRIG: EXT.Trig  
Parity bits  
: None  
Controller: PC-9801 RA (NEC)  
OS: MS-DOS Ver. 3.30, N88-BASIC Ver. 6.0  
Command: [:READ ?]  
Delimiter  
: CR+LF  
Interface function:  
Handshaking  
XON/XOFF  
: Hardware  
: Not used  
: 9-pin D-sub connector  
SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT1, CO  
User code  
:
ASCII code  
Connector  
User connector  
:
24-pin IEEE488 interface bus connector  
All functions except switching the power on and off can be completely remote controlled and measurement data collected via either the  
GP-IB or RS-232C interface  
Please inquire regarding compatibility with the command sets of other manufacturers.  
Output data to a printer (option)  
When an RS-232C compatible PRINTER 9442 is connected,  
you can print measurements by pressing the key if in  
CONNECTOR CABLE 9444  
Cord length  
PRINTER 9442  
approx 1.5m  
manual trigger mode, or the  
(free run) mode.  
key if in internal trigger  
AC ADAPTER 9443  
Judgment  
Item No.  
Measurement function  
Measurement value  
9443-02  
9443-01  
(For the EU) (For Japan)  
9443-03  
(For the America)  
Please specify appropriate model  
number suffix when ordering.  
: Thermal serial dot matrix  
: 112 mm  
: 52.5cps  
Printing method  
Paper width  
Printing speed  
Power supply  
Equipped with a foot switch for printer control  
As an alternative to pressing th  
e
key or the  
key,  
: AC ADAPTER 9443 or supplied nickel-hydride battery  
(capable of printing about 3000 lines on full charge from  
9443)  
you can also connect a foot switch to the external I/O TRIG  
terminal. You can then initiate printing by stepping on the foot  
switch (closing the circuit).  
:
Approx. 160W 66.5H 170D mm; approx. 580 g  
Dimensions and mass  
When you purchase a PRINTER 9442, you must also purchase a CONNECTION  
CABLE 9444 and a AC ADAPTER 9443 to connect it to the DMM.  
4
Efficient  
Evaluation Testing  
PC measurement using the high accuracy  
and broad coverage of the 3238 and 3239  
Example of data processing with Microsoft Excel  
Time  
Current  
Integration  
Time History Graph of Current Integration  
Time  
Battery  
Highly accurate measurement  
with minimal drift  
Discharge Characteristics  
The unit uses self-regulation to suppress drift.  
Also, the DMM is ideal for collecting data over  
extended periods of time.  
Using Excel for efficient data  
processing  
The DMM supports fast data processing  
by allowing you to transfer data directly to  
a worksheet through either the GP-IB or  
RS-232C interface.  
Consult your nearest HIOKI dealer for details on software  
Supports large AC current measurement by clamp sensor  
Easy setup  
Both the 3237, 3238 and 3239 can measure live line currents using an  
optional clamp sensor. Enter the name of the clamp sensor being used  
and display current values simply by selecting a range.  
Clamp sensor settings screen  
Select 9010  
Select the 20 A range.  
From the menu's clamp sensor selection screen, select the name  
of the sensor with the cursor key and press the  
key.  
Then, select the same range as you set for the sensor with the  
cursor key.  
* The accuracy of the clamp sensors shown on the left (when used with the  
DMM) is calculated by taking: the difference in the AC V accuracy for the  
DMM (dgt.) 10 (dgt.).  
For the AC V accuracy of the DMM, see page 6.  
In addition to the sensors described above, you can also connect the 3283, 3284, 3285 (requires the 9094) Clamp On HiTesters, and the 9277, 9278, 9279 (requires the 9555) DC Sensors.  
5
3237, 3238, 3239 common specifications (Accuracy at 23˚C±5˚C (73˚F±9˚F), 80% rh or less)  
DC voltage (DC V)  
AC voltage (AC V)  
Range  
200 mV  
Resolution Full scale  
Input impedance Overload protection  
Range  
Resolution Full scale  
Input impedance Overload protection  
1
µV 199.999mV Greater than 100MΩ  
2000 mV 10 µV 1999.99mV Appox. 1 MΩ  
600 V DC  
1000 V DC  
750 V AC  
2000 mV 10 µV 1999.99mV Greater than 100MΩ  
20  
200  
700  
V
V
V
100 µV 19.9999  
mV 199.999  
10 mV 750.00  
V
V
V
Appox. 1 MΩ  
Appox. 1 MΩ  
Appox. 1 MΩ  
750 V rms, 1000Vpeak  
However, less than  
107 V Hz  
20  
200  
1000  
V
V
V
100 µV 19.9999  
mV 199.999  
10 mV 1000.00  
V
V
V
Appox. 11 MΩ  
Appox. 10 MΩ  
Appox. 10 MΩ  
1
However, less than  
1
107 V Hz  
Resistance (Ω) 2-terminal measurement  
Range  
200  
2000  
20 kΩ 100 mΩ 19.9999kΩ Appox. 100  
Resistance (Ω) at Low Power function 2-terminal measurement  
Open terminal voltage  
Resolution Full scale  
1
Current  
Overload protection  
Range  
2000  
20 kΩ 100 mΩ 19.9999kΩ Appox. 10  
Open terminal voltage Overload protection  
Resolution Full scale  
10 mΩ 1999.99 Ω Appox. 100  
Current  
Ω
mΩ 199.999 Ω Appox. 1 mA 6V DC max.  
Ω
µ
A
0.45V DC max.  
Ω
10 mΩ 1999.99 Ω Appox. 1 mA 6V DC max.  
µ
A
0.45V DC max.  
500Vpeak  
µ
A
A
A
A
A
6V DC max.  
6V DC max.  
6V DC max.  
6V DC max.  
6V DC max.  
200 kΩ  
1
Ω
Ω
199.999kΩ Appox.  
1
µ
A
0.45V DC max.  
200 kΩ  
1
Ω
Ω
Ω
199.999kΩ Appox. 10  
1999.99kΩ Appox. 1 µ  
µ
500Vpeak  
2000 kΩ 10  
1999.99kΩ Appox. 100  
n
A
0.45V DC max.  
2000 kΩ 10  
20 MΩ 100  
Continuity check  
19.9999M  
Ω
Ω
Appox. 100  
n
Range  
2000  
Open terminal voltage Overload protection  
Resolution Full scale  
10 mΩ 1999.99 Ω Appox. 100  
Current  
100 MΩ  
1
100.000M  
Appox. 20n  
Ω
µ
A
0.45V DC max. 500 Vpeak  
For sampling at in the 2 MΩ range or  
the LPΩ 200 kΩ.range or higher  
For fast sampling in the 20 MΩ range or higher.  
Frequency  
A built-in buzzer sounds when the resistance value is less than 50.00 Ω.  
Frequency  
FAST* MEDIUM SLOW  
FAST*  
Diode check  
50 Hz 20 ±1 ms 170 ±5 ms 1,360±50ms  
60 Hz 16.7 ±1 ms 142 ±5 ms 1,420±50 ms  
50 Hz 20 ±1 ms  
60 Hz 16.7 ±1 ms  
Range  
Open terminal voltage Overload protection  
Resolution Full scale  
Current  
2000 mV 10 µV 1999.99mV Appox. 1 mA 6V DC max. 500 Vpeak  
* Approximately 55 ms required for self-calibration at 30-minute intervals.  
3238, 3239 specifications (Accuracy at 23˚C±5˚C (73˚F±9˚F), 80% rh or less)  
AC/DC current (A)  
DC current (DC A) Accuracy %, ppm=reading error, d=digit error  
Range  
200 mA  
Resolution Full scale Internal resistance Overload protection  
µA 199.999mA Appox.  
Sampling  
MEDIUM  
Thermal  
Range  
1
1 Ω  
coefficient  
±
SLOW  
FAST  
250V, 2A fuse  
2000 mA 10 µA 1999.99mA Appox. 100 m  
Ω
200 mA ±0.1 %±6d ±0.1 %±10d ±0.1 %±300d  
100ppm  
150ppm  
±
±
0.6d  
0.6d  
2000 mA ±0.15%±6d ±0.15%±10d 0.15% 300d  
±
±
±
AC current (AC A) 200mA range Accuracy %, ppm=reading error, d=digit error  
AC current (AC A) 2000mA range Accuracy  
Sampling  
MEDIUM  
undefined  
Sampling  
MEDIUM  
undefined  
Thermal  
Thermal  
Range  
Frequency  
coefficient  
coefficient  
SLOW  
FAST  
undefined  
SLOW  
FAST  
undefined  
10 Hz to 20 Hz ±1.0%±200d  
20 Hz to 45 Hz ±0.4%±200d  
45 Hz to 300 Hz ±0.3%±100d  
300 Hz to 1 kHz ±0.3%±100d  
±
±
±
±
±
±
±
0.1 %  
±
20d ±1.2%±200d  
±
±
±
±
±
±
0.12%±20d  
undefined  
undefined  
400ppm  
300ppm  
300ppm  
300ppm  
500ppm  
±20d  
±10d  
±10d  
±10d  
±30d  
±0.6%±200d  
±0.4%±100d  
±0.4%±100d  
±0.6%±200d  
±1.2%±300d  
undefined  
undefined  
undefined  
600ppm  
400ppm  
400ppm  
600ppm  
±
20d  
10d  
10d  
20d  
±0.5%±200d  
±0.4%±200d  
±0.4%±200d  
±0.5%±300d  
±1.0%±300d  
undefined  
±0.6%±200d  
±0.6%±200d  
±0.6%±200d  
±1.2%±300d  
undefined  
undefined  
±
±
±
All  
Ranges  
±0.4%±300d  
±0.4%±300d  
±0.5%±400d  
±1.0%±400d  
±0.6%±300d  
±0.6%±300d  
±1.2%±400d  
undefined  
1
3
kHz to 3 kHz ±0.3%±100d  
kHz to 10 kHz ±0.5%±300d  
0.12%±30d  
10 kHz to 30 kHz ±1.0%±300d  
Specified input is 16 mA or higher  
Additional error due to crest factor: 1<CF<2: ±200d, 2<CF<3: ±500d, 3<CF: Outside the assured accuracy range  
0.1 %  
±
30d  
undefined  
Specified input is 160 mA or higher  
Frequency (Hz) Source is AC V only and input level is higher than 8% of full scale  
Frequency (Hz) Accuracy %, ppm=reading error, d=digit error  
Range  
Internal resistance  
Resolution  
Full scale  
Min. measurement Overload protection  
For all gate times  
Square-wave input between 10 Hz to 300 kHz, 10 V p-p.  
Thermal  
Range  
100 Hz 0.1 mHz 99.9999 Hz Appox. 1M  
Ω
Ω
Ω
Ω
Ω
10 Hz  
coefficient  
600 V DC  
1
kHz mHz 999.999 Hz Appox. 1M  
1
10 Hz  
10 Hz  
10 Hz  
10 Hz  
750 V rms,  
±
0.015%  
±
2d  
±5 ppm  
All Ranges  
10 kHz 10 mHz 9.99999kHz Appox. 1M  
100 kHz 100mHz 99.9999kHz Appox. 1M  
300 kHz  
1000Vpeak  
However, less  
than 107 V Hz  
Frequency gate time  
1
Hz 999.999kHz Appox. 1M  
FAST  
MEDIUM  
110 ±10 ms  
SLOW  
15 ±6 ms  
1,010 ±20 ms  
Measurement time: from gate time to the input signal period 2  
3239 specifications (Accuracy at 23˚C±5˚C (73˚F±9˚F), 80% rh or less)  
Resistance (Ω) 4-terminal measurement  
Range Resolution Full scale Current  
Resistance (Ω) at Low Power function 4-terminal measurement  
Open terminal voltage  
Open terminal voltage Overload protection  
Overload protection  
Range Resolution Full scale  
2000 10 mΩ 1999.99 Ω Appox. 100  
20 kΩ 100 mΩ 19.9999kΩ Appox. 10  
Current  
200  
Ω
1
mΩ 199.999 Ω Appox. 1 mA 6V DC max.  
Ω
µ
A
0.45V DC max.  
V, Ω  
terminal  
V, Ω  
500Vpeak  
terminal  
µ
A
0.45V DC max. 500Vpeak  
2000  
Ω
10 mΩ 1999.99 Ω Appox. 1 mA 6V DC max.  
SENSE  
terminal  
200 kΩ  
1
Ω
Ω
199.999kΩ Appox.  
1
µ
A
0.45V DC max.  
0.45V DC max.  
20 kΩ 100 mΩ 19.9999kΩ Appox. 100  
µ
A
A
A
6V DC max.  
6V DC max.  
6V DC max.  
SENSE  
400Vpeak  
400Vpeak  
terminal  
200 kΩ  
1
Ω
Ω
199.999kΩ Appox. 10  
1999.99kΩ Appox.  
µ
2000 kΩ 10  
1999.99kΩ Appox. 100n  
A
2000 kΩ 10  
1
µ
6
3237 DC voltage (DC V) Accuracy %, ppm=reading error, d=digit error  
3238, 3239 DC voltage (DC V) Accuracy %, ppm=reading error, d=digit error  
Sampling  
MEDIUM  
Sampling  
MEDIUM  
Thermal  
Thermal  
Range  
coefficient  
coefficient  
SLOW  
FAST  
300d  
100d  
SLOW  
±0.012%±6d  
FAST  
0.02% 300d  
0.015%  
200 mV ±0.026%±6d  
±0.026%±10d  
±
0.035%  
±
±
±
±
±
±
20ppm  
15ppm  
20ppm  
20ppm  
20ppm  
±0.6d  
±0.2d  
±0.5d  
±0.2d  
±0.2d  
±0.012%  
±10d  
±
±
±
±
±
±
±
12ppm  
10ppm  
16ppm  
16ppm  
16ppm  
±
±
±
±
±
0.6d  
0.2d  
0.5d  
0.2d  
0.2d  
2000mV ±0.025%±2d  
±0.025%±8d  
±
0.03%  
±
±0.01 %±2d  
±0.01 %±8d  
±
±
±
±
±
100d  
100d  
100d  
100d  
20  
V
V
V
±0.028%±5d ±0.028%±10d  
±
±
±
0.035%  
0.035%  
0.035%  
±
100d  
100d  
100d  
±0.016%±5d ±0.016%±10d  
0.02%  
0.02%  
0.02%  
±
±
±
200  
1000  
±0.028%±2d  
±0.028%±2d  
±0.028%±8d  
±0.028%±8d  
±
±
±0.016%±2d  
±0.016%±2d  
±0.016%±8d  
±0.016%±8d  
CMRR (50/60Hz Rl=1kΩ): SLOW 130dB, MEDIUM 90dB, FAST 20dB NMRR (50/60Hz ): SLOW 70dB, MEDIUM 50dB, FAST 0dB  
3237 AC voltage (AC V) Accuracy %, ppm=reading error, d=digit error  
3238, 3239 AC V Accuracy %, ppm=reading error, d=digit error  
Sampling  
MEDIUM  
undefined  
Sampling  
MEDIUM  
undefined  
Thermal  
Thermal  
Range  
Frequency  
coefficient  
±
coefficient  
SLOW  
FAST  
undefined  
SLOW  
FAST  
undefined  
10 Hz to 20 Hz ±1.5%±200d  
20 Hz to 45 Hz ±0.5%±200d  
45 Hz to 300 Hz ±0.2%±100d  
300 Hz to 3 kHz ±0.2%±100d  
0.15%  
±
20d ±0.8%±200d  
±
±
±
±
±
±
±
800ppm  
200ppm  
100ppm  
100ppm  
100ppm  
300ppm  
300ppm  
±20d  
±20d  
±10d  
±10d  
±10d  
±40d  
±40d  
undefined  
undefined  
±
±
±
±
500ppm  
200ppm  
200ppm  
300ppm  
±
20d ±0.2%±200d  
10d ±0.1%±100d  
10d ±0.1%±100d  
20d ±0.1%±100d  
undefined  
undefined  
±0.5%±300d  
±0.2%±200d  
±0.3%±200d  
±1.5%±600d  
undefined  
undefined  
±
±
±
±0.3%±200d  
±0.1%±200d  
±0.1%±200d  
±0.3%±400d  
±0.3%±400d  
undefined  
±0.2%±300d  
±0.3%±300d  
±1.5%±700d  
undefined  
±0.1%±300d  
±0.1%±300d  
±0.3%±500d  
±0.3%±500d  
All  
3
kHz to 10 kHz ±0.3%±200d  
Ranges  
10 kHz to 30 kHz ±1.5%±600d  
±
0.15%  
±
60d ±0.3%±400d  
±0.3%±400d  
30 kHz to 50 kHz  
50 kHz to 100kHz  
100kHz to 300kHz  
undefined  
undefined  
undefined  
undefined  
undefined  
undefined  
undefined  
undefined  
±
±
1.5%±  
±
1000d  
5000d  
±
1.5%  
±
±
1000d  
5000d  
±
1.5%  
±
1100d  
5000d  
±
0.15%  
±100d  
undefined  
undefined  
5.0%  
±5.0%  
±
5.0%  
±
±
0.5%±  
500d  
The accuracy above is standard for inputs higher than 8% of full scale (higher than 160 V for a range of 750 V).  
Additional error due to crest factor: 1<CF<2: ±200d, 2<CF<3: ±0.2%rdg.±500d(3237), ±500d(3238, 3239), 3<CF: Outside the assured accuracy range  
3237 Resistance (Ω) Accuracy %, ppm=reading error, d=digit error  
3238, 3239 Resistance (Ω) Accuracy %, ppm=reading error, d=digit error  
Sampling  
MEDIUM  
±0.05 %±8d ±0.05 %±18d  
Sampling  
MEDIUM  
±0.03 %±8d ±0.03 %±18d  
±0.02 %±2d ±0.02 %±12d  
±0.02 %±2d ±0.02 %±12d  
±0.02 %±2d ±0.02 %±12d  
±0.03 %±2d ±0.03 %±12d  
Measure-  
ment  
Thermal  
coefficient  
Thermal  
Range  
200  
2000  
coefficient  
SLOW  
FAST  
SLOW  
FAST  
Ω
±
±
±
±
±
0.05%  
±
±
±
±
±
300d  
±50ppm  
±50ppm  
±50ppm  
±50ppm  
±50ppm  
±
±
±
±
±
0.8d  
0.2d  
0.2d  
0.2d  
0.2d  
±
±
±
±
±
0.03%  
±
±
±
±
±
300d  
±
±
±
±
±
30ppm  
20ppm  
20ppm  
20ppm  
30ppm  
±0.8d  
±0.2d  
±0.2d  
±0.2d  
±0.2d  
Ω
±0.05 %±2d ±0.05 %±12d  
0.05%  
0.05%  
0.05%  
0.05%  
100d  
100d  
200d  
200d  
0.02%  
0.02%  
0.02%  
0.03%  
100d  
100d  
200d  
200d  
20 kΩ ±0.05 %±2d ±0.05 %±12d  
200 kΩ ±0.05 %±2d ±0.05 %±12d  
2000 kΩ ±0.05 %±2d ±0.05 %±12d  
2-  
terminal  
measurement  
20 MΩ ±0.3 %±4d ±0.3 %±20d ±0.3 %±200d  
100 MΩ ±3.0 %±10d ±3.0 %±50d ±3.0 %±500d  
±
300ppm  
±
0.4d  
±0.2 %±4d ±0.2 %±20d ±0.2 %±200d  
±3.0 %±10d ±3.0 %±50d ±3.0 %±500d  
±
200ppm  
±
0.4d  
±
0.3%  
±
1d  
±
0.3%  
±
1d  
After zero adjustment. When measuring high resistance, use a shielded cable such as the 9236 CONNECTION CORD (1.7m).  
3237 Resistance (Ω) Accuracy at Low Power function  
3238, 3239 Resistance (Ω) Accuracy at Low Power function  
Sampling  
MEDIUM  
±0.05 %±6d ±0.05 %±14d  
Sampling  
MEDIUM  
±0.02 %±6d ±0.02 %±14d  
±0.02 %±6d ±0.02 %±14d  
±0.02 %±6d ±0.02 %±14d  
Measure-  
ment  
Thermal  
Thermal  
coefficient  
Range  
2000  
coefficient  
SLOW  
FAST  
SLOW  
FAST  
Ω
±
±
±
0.05 %  
±
±
±
300d  
±
±
±
50ppm  
50ppm  
50ppm  
±
±
±
0.6d  
0.6d  
0.6d  
±
±
±
0.02%  
±
±
±
300d  
±
±
±
20ppm  
20ppm  
20ppm  
±0.6d  
±0.6d  
±0.6d  
20 kΩ ±0.05 %±6d ±0.05 %±14d  
200 kΩ ±0.05 %±6d ±0.05 %±14d  
0.05 %  
0.05 %  
300d  
300d  
0.02%  
0.02%  
300d  
300d  
2-  
terminal  
measurement  
2000 kΩ  
±0.3 %±6d  
±0.3 %±20d  
±0.3 %±500d  
±
300ppm  
±
0.6d  
±0.2 %±6d  
±0.2 %±20d  
±0.2 %±300d  
±200ppm±0.6d  
After zero adjustment. When measuring high resistance, use a shielded cable such as the 9236 CONNECTION CORD (1.7m).  
3237 Continuity check Accuracy %, ppm=reading error, d=digit error 3238, 3239 Continuity check Accuracy %, ppm=reading error, d=digit error  
Sampling  
FAST only  
Sampling  
FAST only  
±0.02 %±300d  
Thermal  
Thermal  
Range  
2000  
coefficient  
±
coefficient  
Ω
±0.05 %±300d  
50ppm  
±0.6d  
±20ppm±0.6d  
3237 Diode check Accuracy %, ppm=reading error, d=digit error  
3238, 3239 Diode check Accuracy %, ppm=reading error, d=digit error  
Sampling  
MEDIUM  
Sampling  
MEDIUM  
±0.01 %±8d  
Thermal  
Thermal  
Range  
2000  
coefficient  
±
coefficient  
SLOW  
0.025%  
FAST  
0.03% 100d  
SLOW  
±0.01 %±2d  
FAST  
0.015% 100d  
Ω
±
±2d  
±0.025%  
±8d  
±
±
15ppm  
±0.2d  
±
±
±10ppm±0.2d  
4-terminal measurement  
Resistance (Ω) Accuracy %, ppm=reading error, d=digit error  
4-terminal measurement  
Resistance (Ω) Accuracy at Low Power function  
Sampling  
MEDIUM  
±0.03 %±8d ±0.03 %±18d  
Sampling  
MEDIUM  
No range  
Measure-  
ment  
Thermal  
coefficient  
Thermal  
Range  
200  
2000  
coefficient  
SLOW  
FAST  
0.03 % 300d  
100d  
SLOW  
No range  
FAST  
No range  
Ω
±
±
±
±
±
±
±30ppm  
±20ppm  
±20ppm  
±20ppm  
±30ppm  
±
±
±
±
±
0.8d  
0.2d  
0.2d  
0.2d  
0.2d  
No range  
Ω
±0.02 %±2d ±0.02 %±12d  
0.02 %  
0.02 %  
0.02 %  
0.03 %  
±
±
±
±
±0.02 %±6d ±0.02 %±14d  
±0.02 %±6d ±0.02 %±14d  
±0.02 %±6d ±0.02 %±14d  
±
±
±
0.02%  
0.02%  
0.02%  
±
±
±
300d  
300d  
300d  
±
±
±
20ppm  
20ppm  
20ppm  
±0.6d  
±0.6d  
±0.6d  
4-  
20 kΩ ±0.02 %±2d ±0.02 %±12d  
200 kΩ ±0.02 %±2d ±0.02 %±12d  
2000 kΩ ±0.03 %±2d ±0.03 %±12d  
100d  
200d  
200d  
terminal  
measurement  
±0.2 %±6d  
±0.2 %±20d  
±0.2 %±300d  
±200ppm±0.6d  
The accuracy quoted above is for a contact resistance of 100 Ω or less.  
7
3237, 3238, 3239 General Specifications  
AC measurement: True RMS value measurement  
Crest factor: 3.0 max.  
Ancillary functions: Comparator, Average (0 to 99 times), Zero Adjust, Trigger (the display changes when the trigger is activated),  
and the Save/Load functions. (Up to 30 types of setting conditions)  
Interface: External input/output, RS-232C and GP-IB (option -01 specifications)  
Display: LED max. 199999 (999999 for frequency)  
Sampling rate(see page 1): SLOW approx. 1 samples/s  
MEDIUM approx. 8 to 9 samples/s  
FAST approx. 300 samples/s (Does not apply at resistances higher than 2MΩ, or LPΩ higher than 200kΩ)  
(self-calibration takes place for approximately 55 ms at 30-minute intervals for FAST sampling only.)  
Range selection: Auto and Manual  
Applicable standards: Safety: EN61010-1+A2, EN61010-2-031  
Lo terminal: CAT I (500V), CAT II (300V)  
Hi terminal: CAT I (1000V), CAT II (600V)  
EMC: EN61326+A1 Class B, EN61000-3-2+A1+A2, EN61000-3-3  
Ambient temperature of use: 0 to 40 ˚C(32˚F to 104˚F) 80%RH (no condensation)  
Storage temperature range: -10 to 50˚C(-14˚F to 122˚F) 70%RH (no condensation)  
Power supply: Select from AC 100 V/120 V/220 V/240 V, (50/60 Hz) specify when ordering  
Maximum rated power: 15 VA  
Dimensions and mass: Approx. 215 W80 H265 D mm, 2.6kg  
Approx 8.5˝ W 3.5˝ H 10.4˝ D, 91.7 oz.  
Options  
Economical Type  
RS-232C cable  
RS-232C CABLE 9637 (9pin-9pin, Reverse type/1.8m)  
RS-232C CABLE 9638 (9pin-25pin, Reverse type/1.8m)  
DIGITAL HiTESTER 3237  
DIGITAL HiTESTER 3237-01 (with GP-IB)  
Advanced Type  
GP-IB cable  
The specifications of the 3237, 3238 and 3239 are –01 specifications  
GP-IB CABLE 9151-02 (2m)  
GP-IB CABLE 9151-04 (4m)  
DIGITAL HiTESTER 3238  
DIGITAL HiTESTER 3238-01 (with GP-IB)  
Printer  
4-terminal Ω function & Advanced Type  
PRINTER  
9442  
CONNECTOR CABLE 9444 (For 9442 printer)  
DIGITAL HiTESTER 3239  
DIGITAL HiTESTER 3239-01 (with GP-IB)  
AC ADAPTER  
AC ADAPTER  
AC ADAPTER  
9443-01 (For 9442 printer, Japan)  
9443-02 (For 9442 printer, EU)  
9443-03 (For 9442 printer, America)  
RECORDING PAPER 1196 (For printer, 10 rolls)  
When you purchase a PRINTER 9442, you must also purchase a 9444  
CONNECTOR CABLE and a AC ADAPTER 9443 to connect it to the DMM.  
cord length 65cm  
For printer specifications, see page 3.  
TEST LEAD 9170-10 (included)  
4-Terminal Ω measurement probe for 3239  
CLIP-TYPE LEAD 9287-10 (Approx. 85 cm between connectors, and 8 cm between probes)  
CLIP-TYPE LEAD 9452(Approx. 80 cm between connectors, and 20 cm between probes)  
FOUR-TERMINAL LEAD 9453(Approx. 80 cm between connectors, and 30 cm between probes)  
PIN-TYPE LEAD 9461(Approx. 40 cm between connectors, and 25 cm between probes)  
9010-50  
Options  
Clamp sensors  
CLAMP ON PROBE 9010-50 (10/20/50/100/200/500A AC )  
CLAMP ON PROBE 9018-50 (10/20/50/100/200/500A AC, Broadband type)  
CLAMP ON PROBE 9132 (20/50/100/200/500/1000A AC )  
9287-10  
9452  
9453  
9461  
For Clamp sensors specifications, see page 4.  
HIOKI (Shanghai) Sales & Trading Co., Ltd. :  
DISTRIBUTED BY  
1904 Shanghai Times Square Office, 93 Huai Hai Zhong Road  
Shanghai, P.R.China POSTCODE: 200021  
TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360  
E-mail: info-sh@hioki.cn  
Beijing Office :  
HEAD OFFICE :  
A-2602 Freetown, 58 Dong San Huan Nan Road  
Beijing, P.R.China POSTCODE: 100022  
TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090  
E-mail: info-bj@hioki.cn  
81 Koizumi, Ueda, Nagano, 386-1192, Japan  
TEL +81-268-28-0562 / FAX +81-268-28-0568  
E-mail: os-com@hioki.co.jp  
Guangzhou Office :  
HIOKI USA CORPORATION :  
Room 303, Profit Plaza, No.76, West Huangpu Road  
Guangzhou, P.R.China POSTCODE: 510623  
TEL +86-20-38392673/2676 FAX +86-20-38392679  
E-mail: info-gz@hioki.cn  
6 Corporate Drive, Cranbury, NJ 08512 USA  
TEL +1-609-409-9109 / FAX +1-609-409-9108  
E-mail: hioki@hiokiusa.com  
All information correct as of Sep. 12, 2007. All specifications are subject to change without notice.  
3239E4-79M-03P Printed in Japan  

相关型号:

3239-00

2.2 GHz Integer-N PLL for Low Phase Noise Applications
PSEMI

3239-11

2.2 GHz Integer-N PLL for Low Phase Noise Applications
PSEMI

3239-12

2.2 GHz Integer-N PLL for Low Phase Noise Applications
PSEMI

3239-254-50

KR Electronics part number 3239-254-50 is a 253.85 MHz bandpass filter
KR

3239-254-50+

KR Electronics part number 3239-254-50 is a 253.85 MHz bandpass filter
KR

323912

Standard Terminals and Splices
MACOM

323913

Standard Terminals and Splices
MACOM

323914

TERMINAL, NYLON - PIDG - RING TONGUE WIRE SIZE: 26-22
MACOM

323915

Standard Terminals and Splices
MACOM

323916

Standard Terminals and Splices
MACOM

323930

FERRULE ASSEMBLY, TERMASHIELD
MACOM

323931

Cumulative Trauma Disorders can result from the prolonged use of manually powered hand tools.
MACOM