NLP25-7624 [ARTESYN]

LOW TO MEDIUM POWER AC/DC POWER SUPPLIES; 中低功率AC / DC电源
NLP25-7624
型号: NLP25-7624
厂家: ARTESYN TECHNOLOGIES    ARTESYN TECHNOLOGIES
描述:

LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
中低功率AC / DC电源

文件: 总3页 (文件大小:49K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
NLP25 Series  
S i n g l e , d u a l a n d t r i p l e o u t p u t  
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 20-25W AC/DC Universal Input Switch Mode Power Supplies  
1
4.00 x 2.07 x 0.91 inch package  
Overvoltage protection and short circuit protection  
25W with free air convection cooling  
EN55022, EN55011 conducted emissions level B  
UL, VDE and CSA safety approvals  
The NLP25 series is a 25W universal input AC/DC power supply on a 4.00 x 2.07 inch  
card with a profile of less than 1 inch. The availability of four single output and three  
multiple output models in an extremely small package size make the NLP25 ideal for  
use in space critical, low power communication applications requiring an off line  
power solution. The NLP25 provides 25W of output power with free air convection  
cooling which can peak at 30W for 60 seconds. Standard features include  
overvoltage and short circuit protection. The series, with full international safety  
approvals and the CE mark, meets conducted emissions EN55022 level B and  
complies to EN61000-4-2,-3,-4, -5 and -6 immunity standards. The NLP25 series is  
designed for use in off line, low power data networking and computer applications  
with limited space, such as hubs, routers, POS terminals, external disk storage and  
cable modems. The availability of 5V outputs in single and multiple configurations  
provides a solution for a myriad of microprocessor applications.  
2 YEAR WARRANTY  
All specifications are typical at nominal input, full load at 25°C unless otherwise stated  
SPECIFICATIONS  
OUTPUT SPECIFICATIONS  
EMC CHARACTERISTICS  
Radiated emissions  
Conducted emissions  
Electrostatic discharge  
EN55022/11, FCC part 15  
EN55022/11, FCC part 15  
EN61000-4-2  
Level A  
Level B  
Level 2  
Total regulation  
(Line and load)  
Main output  
Auxiliary outputs  
±2.0%  
±5.0%  
Overshoot/undershoot  
Transient response  
At turn-on  
2.0%  
Electrical fast  
EN61000-4-4  
Level 3  
transients/bursts  
Main output  
50% to 100%  
full load step  
±5.0% max. dev.,  
1ms recovery  
to 1.0%  
Surge susceptibility  
RF field susceptibility  
RF conducted  
disturbance  
EN61000-4-5  
EN61000-4-3  
EN61000-4-6  
Level 3  
Level 3  
Level 3  
Temperature coefficient  
Overvoltage protection  
Short circuit protection  
±0.02% /°C  
See table  
GENERAL SPECIFICATIONS  
Main output  
Hold-up time  
Efficiency  
110VAC @ full load  
5ms typ.  
70% typ.  
Continuous with  
autorestart  
110VAC @ full load  
Minimum output current  
INPUT SPECIFICATIONS  
Input voltage range  
See table  
Isolation voltage  
Input/output  
Input/chassis  
3000VAC  
1500VAC  
Switching frequency  
Fixed  
60kHz, ±10kHz  
Universal input  
90 to 264VAC  
127 to 375VDC  
Approvals and  
standards  
(See Notes 4, 8)  
EN60950, IEC950  
VDE0805, UL1950  
CSA C22.2 No. 950  
Input frequency range  
Input current  
47Hz to 440Hz  
90VAC  
230VAC  
0.75A rms max.  
0.35A rms max.  
Weight  
MTBF  
115g (4oz)  
MIL-HDBK-217F  
150,000 hours min.  
Safety ground  
leakage current  
120VAC, 60Hz  
230VAC, 50Hz  
0.2mA  
0.4mA  
ENVIRONMENTAL SPECIFICATIONS  
Thermal performance  
(See Notes 7, 8)  
Operating ambient, FL  
Non-operating  
0°C to 50°C, ambient,  
convection cooled  
0°C to +50°C  
-40°C to +85°C  
Full load  
Peak  
See Note 1  
Relative humidity  
Altitude  
Non-condensing  
5% to 95% RH  
Operating  
Non-operating  
10,000 feet max.  
30,000 feet max.  
Vibration (See Note 6)  
Shock  
5Hz to 500Hz  
MIL-STD-810E  
2.4G rms peak  
516.4 Part IV  
File Name: NLP25.PDF Rev: 01 Jan 2000  
NLP25 Series  
S i n g l e , d u a l a n d t r i p l e o u t p u t  
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 20-25W AC/DC Universal Input Switch Mode Power Supplies  
For the most current data and application support visit www.artesyn.com/powergroup/products.htm  
2
OUTPUT CURRENT  
OUTPUT  
POWER  
OUTPUT  
VOLTAGE  
OVP  
TOTAL  
MODEL  
(2)  
RIPPLE  
(3)  
(1)  
(5)  
(3)  
MIN  
MAX  
2.0A  
0.8A  
0.1A  
2.0A  
0.8A  
0.1A  
2.0A  
0.8A  
5.0A  
2.08A  
1.04A  
0.52A  
PEAK  
2.5A  
1.2A  
THRESHOLD  
REGULATION  
NUMBER  
20.8W  
20.1W  
19.6W  
+5V (I )  
A
0.2A  
50mV  
5.6V to 6.9V  
±2.0%  
±5.0%  
±5.0%  
±2.0%  
±5.0%  
±5.0%  
±2.0%  
±5.0%  
±2.0%  
±2.0%  
±2.0%  
±2.0%  
NLP25-7608  
NLP25-7607  
NLP25-7629  
+12V (I )  
B
0.1A  
0A  
120mV  
50mV  
–12V (I )  
C
0.15A  
2.5A  
1.2A  
0.15A  
2.5A  
1.2A  
6.0A  
2.5A  
1.25A  
0.6A  
+5V (I )  
A
0.2A  
0.1A  
0A  
50mV  
5.6V to 6.9V  
+12V (I )  
B
120mV  
50mV  
–5V (I )  
C
+5V (I )  
A
0.2A  
0.1A  
0A  
50mV  
5.6V to 6.9V  
5.6V to 6.9V  
+12V (I )  
B
120mV  
50mV  
25W  
25W  
25W  
25W  
+5V  
+12V  
+24V  
+48V  
NLP25-7605  
NLP25-7612  
NLP25-7624  
NLP25-7617  
0A  
120mV  
150mV  
150mV  
14V to 16.7V  
29V to 34.2V  
55V to 60V  
0A  
0A  
Notes  
OUTPUT PIN CONNECTIONS  
1
2
3
Peak output current lasting less than 60 seconds with duty cycle less than  
5.0% . During peak loading, output voltage may exceed total regulation  
limits.  
20MHz bandwidth, peak to peak, measured differentially with a 12 inch  
twisted pair of number 16 AWG copper wire, terminated with a 47µF  
capacitor of proper polarity and voltage rating.  
Total regulation is defined as the static output regulation at 25°C, including  
initial tolerance, line voltage within stated limit, load current within stated  
limit, and output voltage adjusted to their factory settings. To achieve  
specified regulation on multiple output models, minimum loads are required  
on V(A) and V(B) as outlined in above table.  
J 2  
SINGLE  
V (A)  
DUAL  
No Connection  
Return  
TRIPLE  
V (C)  
Pin 1  
Pin 2  
Pin 3  
Pin 4  
Pin 5  
Return  
V (A)  
Return  
V (A)  
V (A)  
Return  
V (A)  
Return  
Return  
V (B)  
V (B)  
4
To maintain user-system safety approvals, the input power cable must be  
appropriately rated and approved.  
5
6
Main output voltage is protected by a Zener diode.  
Three orthogonal axes, random vibration 10 minutes for each axes, 2.4G  
rms 5Hz to 500Hz.  
INPUT  
7
8
CAUTION: Allow a minimum of 5 seconds after disconnecting line power  
when making thermal measurements.  
This product is only for inclusion by professional installers within other  
equipment and must not be operated as a stand alone product.  
PIN CONNECTIONS  
J 1  
Pin 1  
AC Ground  
AC Line  
Pin 3  
Pin 5  
AC Neutral  
www.a rte s yn.com  
File Name: NLP25.PDF Rev: 01 Jan 2000  
NLP25 Series  
S i n g l e , d u a l a n d t r i p l e o u t p u t  
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 20-25W AC/DC Universal Input Switch Mode Power Supplies  
For the most current data and application support visit www.artesyn.com/powergroup/products.htm  
3
4.00 ±0.02  
(101.60 ±0.5)  
3.730 ±0.02  
(94.74 ±0.5)  
Maximum  
Component  
Height 0.91 (23.11)  
1
2.07 ±0.02  
(52.58 ±0.5)  
1.80 ±0.02  
(45.72 ±0.5)  
J2  
J1  
5
3
1
If Metallic fastners are used, Max. stand-off dia.  
should be 0.212 (5.38) and the screw or washer  
should not protrude beyond the circle.  
ø0.125 ±0.01  
(ø3.18 ±0.25)  
ALL DIMENSIONS IN INCHES (mm)  
Input and output connectors Mating connectors  
AC (J 1) connector type  
AC (J 1) mating connector type  
Molex 22-23-2051 or equivalent.  
Molex 22-01-2057 with Molex  
08-52-0123 crimp terminals  
or equivalent.  
DC (J 2) connector type  
Molex 22-23-2051 or equivalent.  
DC (J 2) mating connector type  
Molex 22-01-2057 with Molex  
08-52-0123 crimp terminals  
or equivalent.  
International Safety Standard Approvals  
VDE0805/EN60950/IEC950 File No. 10401-3336-0118  
UL1950 File No. E136005  
CSA C22.2 No. 950 File No. LR41062  
Data Sheet © Artesyn Technologies  
® 2002  
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising  
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.  
www.a rte s yn.com  
File Name: NLP25.PDF Rev: 01 Jan 2000  

相关型号:

NLP25-7624J

20-25 W AC/DC Universal Input Switch Mode Power Supplies
EMERSON-NETWO

NLP25-7629

LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
ARTESYN

NLP25-7629J

20-25 W AC/DC Universal Input Switch Mode Power Supplies
EMERSON-NETWO

NLP250

250 W AC/DC Universal Input Switch Mode Power Supplies
ARTESYN

NLP250

Single Output Medical safeties
EMERSON-NETWO

NLP250-DC

Single Output
EMERSON-NETWO

NLP250MEDICAL

Active PFC and EN61000-3-2 compliant
EMERSON-NETWO

NLP250MEDICAL_09

Active PFC and EN61000-3-2 compliant
EMERSON-NETWO

NLP250MEDICAL_0910

Single Output Medical safeties
EMERSON-NETWO

NLP250N-48S12J

Single Output
EMERSON-NETWO

NLP250N-99S12J

Single Output Medical safeties
EMERSON-NETWO

NLP250N-99S24J

Single Output Medical safeties
EMERSON-NETWO