LCM300U-T [ARTESYN]

AC/DC CONVERTER 36V 300W;
LCM300U-T
型号: LCM300U-T
厂家: ARTESYN TECHNOLOGIES    ARTESYN TECHNOLOGIES
描述:

AC/DC CONVERTER 36V 300W

文件: 总8页 (文件大小:478K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
ARTESYN LCM300  
300 Watts Bulk Front End  
Advanced Energy’s Artesyn LCM300 series provide for a very  
wide range of AC-DC embedded power requirement. Featuring  
high build quality with robust screw terminals, long life, and  
typical full-load efficiency of greater than 91 percent, these units  
are ideal for use in industrial and medical applications. They are  
backed by a comprehensive set of industrial and medical safety  
approvals and certificates. Variable-speed ‘Smart Fans’ draw  
on software controls developed by Advanced Energy to match  
fan speed to the unit’s cooling requirement and load current.  
Slowing the fan not only saves power but also reduces wear,  
thus extending its life.  
AT A GLANCE  
Total Power:  
300 W  
Input Voltage:  
85 to 264 VAC  
# of Outputs:  
Single  
SPECIAL FEATURES  
Compliance  
EMI Class B  
EN61000 Immunity  
RoHS 3  
310 W output power (350 W at 45 °C  
for 24 V and 36 V models)  
Low cost  
PMBUS  
1.61” x 4.0” x 7.0”  
7.1 W/inꢀ  
SAFETY  
Industrial/Medical safety  
-40 °C to 70 °C with derating  
Optional 5 V @ 2 A housekeeping  
High efficiency: 91% @ 230 VAC  
Variable speed “Smart Fans”  
DSP controlled  
UL62368-1  
508/1598/1433  
60601-1 Ed 3  
CSA  
TUV  
62368-1  
62368-1  
60601-1  
China CCC  
Conformal coat option  
Wide adjustment range  
Margin programming  
OR-ing FET  
CB Scheme Report/Cert  
* Note: LCM300 tested according to the medical standard IEC  
60601-1-2 4th Edition.  
PMBus compliant  
©2021 Advanced Energy Industries, Inc.  
LCM300  
ELECTRICAL SPECIFICATIONS  
Input  
Input range  
90 - 264 VAC (Operating)  
115/230 VAC (Nominal)  
TERMINAL BLOCK  
Frequency  
47 - 63 Hz, Nominal 50/60  
Input fusing  
Internal 8 A fuses, both lines fused  
≤ 20 A peak, cold start at 25 °C  
0.98 typical, meets EN61000-3-2  
Meets IEC 61000-3-2 requirements  
5 Arms max input current, at 90 VAC  
20 ms minimum for main O/P, at full rated load  
> 91% typical at full load / 230 VAC nominal  
< 0.3 mA at 240 VAC  
Inrush current  
Power factor  
Harmonics  
Input current  
Hold up time  
Efficiency  
Leakage current  
ON/OFF power switch  
Power line transient  
Isolation  
N/A  
MOV directly after the fuse  
Isolation: PRI-Chassis 2500 VDC Basic  
PRI-SEC 4000 VAC Reinforced 2xMOPP  
SEC-Chassis 500 VDC  
LCM300Q Efꢀciency Without the 5 Vsb  
92.00  
90.00  
88.00  
86.00  
84.00  
82.00  
80.00  
78.00  
76.00  
100 Vac  
230 Vac  
25  
50  
75  
100  
Loading %  
2
advancedenergy.com  
LCM300  
ELECTRICAL SPECIFICATIONS (CONTINUED)  
Output  
Output rating  
See table 1  
0.5%  
90 - 264 VAC  
90 - 264 VAC  
Set point  
Total regulation range  
Main output 2%  
5 Vsb 1%  
Combined line/load/transient when measured  
at output terminal  
Rated load  
310 W (360 W for current Q and U variants)  
Derate linear to 50% from 50 °C to 70 °C  
No loss of regulation  
Minimum load  
Main output @ 0.0 A  
5 Vsb @ 0.0 A  
Output noise (PARD)  
1% max p-p  
Main output  
100 mV max p-p  
5 Vsb output  
Measured with a 0.1 μF Ceramic and 10 μF  
Tantalum Capacitor on any output, 20 MHz  
Output voltage overshoot  
Transient response  
No overshoot/undershoot outside the regulation  
band during on or off cycle  
< 300 μSec  
50% load step @ 1 A/μs  
Step load valid between 10% to 100% of output  
rating  
Recovery time to within 1% of set point at onset  
of transient  
Max units in parallel  
Short circuit protection  
Remote sense  
Up to 10  
Protected, no damage to occur  
Bounce mode  
Compensation up to 500 mV  
Standard per safety requirements  
Analog sharing control  
Output isolation  
Forced load sharing  
Overload protection (OCP)  
To within 10% of all shared outputs  
105% to 125%  
120% to 170%  
Main output  
5 Vsb output  
Overvoltage protection (OVP)  
125% to 145%  
110% to 125%  
12 V output  
5 Vsb output  
ENVIRONMENTAL SPECIFICATIONS  
Operating temperature  
Storage temperature  
Humidity  
-40 °C to +70 °C, linear derating to 50% from 50 °C to 70 °C  
-40 °C to +85 °C  
10 to 90%, non-condensing. Operating. Conformal coat option available  
< 45 dBA, 80% load at 40 °C; Fan Off when unit is inhibited  
Fan noise  
Altitude  
Operating - 16,405 feet (5000m)  
Storage - 30,000 feet  
Shock  
MIL-STD-810F 516.5, Procedure I, VI. Storage  
MIL-STD-810F 514.5, Cat. 4, 10. Storage  
Vibration  
advancedenergy.com  
3
LCM300  
ORDERING INFORMATION  
Nominal  
Output  
Voltage Set  
Point  
Current  
Output  
Ripple  
P/P (0-50 ˚C)  
Max  
Continuous  
Power  
Combined  
Line/Load  
Regulation  
Model  
Number*  
Set Point  
Tolerance  
Adjustment  
Range  
Output  
Min  
Max  
LCM300L  
LCM300N  
LCM300Q  
LCM300U  
LCM300W  
12 V  
15 V  
24 V  
36 V  
48 V  
12 V  
15 V  
24 V  
36 V  
48 V  
0.5%  
0.5%  
0.5%  
0.5%  
0.5%  
9.6 - 14.4 V  
14.25 - 19.5 V  
19.2 - 28.8 V  
28.8 - 43.2 V  
43.0 - 60.0 V  
0 A  
0 A  
0 A  
0 A  
0 A  
25.0 A  
20.0 A  
12.5 A  
8.4 A  
120 mV  
150 mV  
240 mV  
240 mV  
280 mV  
310 W  
310 W  
310 W  
310 W  
310 W  
2%  
2%  
2%  
2%  
2%  
6.3 A  
*Note: 14.5 A rating on LCM300Q-T and 9.7 A on LCM300U-T when max temp does not exceed 45C (Total Power = 350 W)  
LCMXXXXY  
-
A
-
B
-
C
-
###  
Case Size  
Input Termination  
Acoustic Noise  
Option Codes  
Hardware Code  
1-Phase input where XXXX =  
300 = 1.61” x 4.0” x 7.0”, 300 W  
Blank = Standard  
Blank = No Options  
Factory Assigned for  
Modiefied Standards  
T = Terminal Block  
1 = Conformal Coat  
4 = 5 V Standby  
5 = Opt 1 + 4  
Voltage Code Y =  
Code  
L
12  
15  
24  
36  
48  
N
Q
U
W
PN 602-000180-0000  
SCR-PP MC M4X0.7  
W/E-T-W  
INPUT TERMINAL BLOCK  
LED (AC OK)  
POS SK4  
NEG SK5  
LED (DC OK/FAIL)  
Signal Output Signal Connectors (SK2)  
SK2 Mating Connector: JST Part Number PHDR-20VS;  
Contact Pins: JST Part Number SPHD-001T-P0.5  
SK2 SIGNAL CONNECTOR-20WAY  
LED INDICATORS  
2 provided are clearly visible up to a 45 degree offset from vertical with office environment ambient lighting. The status  
is reflected in the indicator color.  
e DC_OK LED LED shall light green if the DC output is within specification, and should be off if the output falls out  
of specification.  
e AC_OK LED LED is green if the AC is within specification and off when out of specification. Note: With 5 V  
standby, Green also indicates that PSU is in standby mode/output off.  
CONTROL SIGNALS  
AC_OK Open collector 0.5 V maximum at 10 mA. Both emitter and collector access provided.  
DC_OK Open collector 0.5 V maximum at 10 mA. Both emitter and collector access provided.  
DC_OK will de-assert when output is loss due to OCP, OVP, OTP, or Fan Fault (for -N option).  
PS_INHIBIT/ENABLE Signal 0.0 - 0.5 V contact closure, output OFF (output ON for LCM300U-T-4-401).  
4
advancedenergy.com  
LCM300  
PIN ASSIGNMENT  
Signals  
Name Description  
Pin Number(s)  
+Vout  
Power rail  
SK4  
SK5  
GND  
Power GND  
Amps per pin  
Signals  
Name Description  
Pin Number(s)  
A2  
EEPROM Address  
1
2
3
4
5
6
7
8
-VPROG  
A1  
Return connection of external supply for Margin Programming  
EEPROM Address  
-Vsense  
ISHARE  
A0  
Remote Sense Return  
Load share voltage  
EEPROM Address  
SDA1  
+VPROG  
SCL1  
+Vsense  
5VSB  
GND  
Serial Data Signal (IꢁC)  
Positive connection of external supply for Margin Programming  
Serial Clock Signal (IꢁC)  
9
Remote Sense Positive  
5V standby  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
2 A  
5V standby Return  
2 A  
5VSB  
5V standby  
N/A  
G_DCOK_C  
GPIOA6  
Global DCOK Collector  
EEPROM Write Protect  
Global DCOK Emitter (GND)  
Return Ground for output signal and IꢁC communication  
Global ACOK Collector  
G_DCOK_E  
GND  
G_ACOK_C  
INH_EN  
Turn Off Main Output  
G_ACOK_E  
Global ACOK Emitter (GND)  
Note: Mating connector for SK2 is:  
LANDWIN: PN 2050S2000 Housing and PN 2053T021V Contact  
CIVILUX: PN CI0120SD000 Housing and PN CI01TD21PE0 Contact  
advancedenergy.com  
5
LCM300  
MECHANICAL DRAWINGS  
177,8 0,5  
Weight: 1.76 lbs (0.8 Kg)  
11,15 REF  
MOUNTING LOCATIONS SCREW  
PENETRATION DEPTH IS 3.0 mm MAX.  
RECOMMENDED SCREW TORQUE:  
M3.5 x 0.6P = 6 - 8kgf-cm  
M4.0 x 0.7P = 8 - 10kgf-cm  
PRODUCT LABEL  
AIR FLOW DIRECTION  
PN 602-000180-0000  
SCR-PP MC M4X0.7  
W/E-T-W  
INPUT TERMINAL BLOCK  
LED (AC OK)  
POS SK4  
NEG SK5  
LED (DC OK/FAIL)  
148,7 0,5  
SK2 SIGNAL CONNECTOR-20WAY  
S-M3-OZ1 (8 PLACES)  
(2X) 29,1 0,5  
(2X) 119,6 0,5  
Airflow direction  
6
advancedenergy.com  
LCM300  
Accessories  
PIN 20  
PIN 2  
PIN 19  
PIN 3  
PIN 1  
300 5 mm  
Order kit part number 73-788-001 for control connector interface with .3m wires attached attached  
PIN 19  
PIN 20  
PIN 3  
PIN 1  
PIN 2  
Order kit part number 73-788-002 for control connector interface with unloaded housing and 20 pins  
Miscellaneous Specifications  
Burn-In  
100% Burn-in at 45 °C, at 80 - 90 % load. Duration of burn-in determined by Quality Assurance Procedures.  
MTBF  
The power supply has a minimum MTBF of 300K hours using the Bell core 332, issue 6 specification @ 25 °C  
and 40 °C, ambient, at full load. With the power supply installed in a system in a 25 °C ambient environment and  
operating at full load, capacitor life shall be 5 years at 50 °C, minimum for ALL electrolytic capacitors contained  
within this power supply. The power supply shall demonstrate a MTBF level of > 500,000 hours.  
Quality Assurance  
Full QAV testing shall be conducted in accordance with Artesyn Embedded Power Standards with reports  
available upon request.  
Warranty  
Artesyn Embedded Power shall warrant the power supply to be free of defects in materials and workmanship for  
a minimum period of three years from the date of shipment, when operated within specifications. The warranty  
shall be fully transferable to the end owner of the equipment powered by the supply.  
advancedenergy.com  
7
ABOUT ADVANCED ENERGY  
Advanced Energy (AE) has devoted more than three  
decades to perfecting power for its global customers. AE  
designs and manufactures highly engineered, precision  
power conversion, measurement and control solutions for  
mission-critical applications and processes.  
Our products enable customer innovation in complex  
applications for a wide range of industries including  
semiconductor equipment, industrial, manufacturing,  
telecommunications, data center computing, and medical.  
With deep applications know-how and responsive service  
and support across the globe, we build collaborative  
partnerships to meet rapid technological developments,  
propel growth for our customers, and innovate the future  
of power.  
For international contact information,  
visit advancedenergy.com.  
Specifications are subject to change without notice. Not responsible  
for errors or omissions. ©2021 Advanced Energy Industries, Inc. All rights  
reserved. Advanced Energy®, AE® and Artesyn™ are U.S. trademarks  
of Advanced Energy Industries, Inc.  
powersales@aei.com (Sales Support)  
productsupport.ep@aei.com (Technical Support)  
+1 888 412 7832  
ENG-LCM300-235-01.07.15.21  

相关型号:

LCM300W

310 Watt Bulk Front End
ARTESYN

LCM300W-T-4

AC/DC CONVERTER 48V 310W
ARTESYN

LCM5024

LCD DOT MATRIX CHARACTER MODULE,96 CHARACTERS
ONSEMI

LCM5059

LCD DOT MATRIX CHARACTER MODULE,96 CHARACTERS
ONSEMI

LCM5129

LCD DOT MATRIX CHARACTER MODULE,96 CHARACTERS
ONSEMI

LCM524

LCD DOT MATRIX CHARACTER MODULE,96 CHARACTERS
ONSEMI

LCM5325-22NTK

Optoelectronic
ETC

LCM5326-22NTK

Optoelectronic
ETC

LCM5327-24NAK

LCD DOT MATRIX GRAPHIC DISPLAY MODULE,BLUE
ONSEMI

LCM5330-22NSK

Optoelectronic
ETC

LCM5331-22NTK

Optoelectronic
ETC

LCM5448-22NAK

LCD DOT MATRIX GRAPHIC DISPLAY MODULE,BLUE
ONSEMI