YA31L7-BOX [AMPHENOL]
Wire Terminal, 185mm2;型号: | YA31L7-BOX |
厂家: | Amphenol |
描述: | Wire Terminal, 185mm2 端子和端子排 |
文件: | 总6页 (文件大小:65K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
BURNDY
Compression
ONE HOLE HYLUG™
CODE CONDUCTOR
STANDARD BARREL
DIE AND COLOR
CODE INFORMATION
BEVELED
ENTRY
INSPECTION
WINDOW
TYPES YA-L,YA-L-TC
CRIMP
COPPER COMPRESSION
TERMINAL
ELECTRO-TIN
PLATED
CABLE
ACCOMMODATION
C-6
UL LISTED 90° C,
600 VOLT TO 35 KV ◆
B
B
90°
T
T
T
45°
L
L
L
Fig. 1
Fig. 3
Fig. 2
Conductor
◆ Installation Tooling
Stud
Hole Tongue
Size
Figure
Dimensions
(T)
Mechanical
MD6, OUR840 BCT500HS
MD7-34R
Hydraulic
Wire
Strip
***
AWG
Dieless
(# of crimps)
Y35,Y39,Y750
Color Die
2
Catalog Number
YAV10-45-BOX
YAV10-BOX
YAV10R-BOX
YAV10R3-BOX
YAV10T2-BOX
YAV10T3-45-BOX
YAV10T3-BOX
YAV10T4-BOX
YA8CL1-BOX
YA8CL1-45
YA8CL1-90
YA8CL2-BOX
YA8CL2-45
YA8CL2-90
YA8CL3-BOX
YA8CL3-45
YA8CL3-90
YA8CL4-BOX
YA8CL4-45
YA8CL4-90
YA8CL-BOX
YA8CL-45
YA8CL-90
YA6CL-BOX
YA6CL-45
YA6CL-90
YA6CL1-BOX
YA6CL1-45
Fig #
1
1
1
1
1
2
1
1
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
MM
Width
(B)
(L)
Y500CTHS Y46, BAT35, BAT750 Code Index Length
.405ꢀ .058ꢀ
.405ꢀ .058ꢀ 1.02ꢀ
.375ꢀ .058ꢀ
.405ꢀ .047ꢀ
.38ꢀ .047ꢀ 1.12ꢀ
.405ꢀ .047ꢀ 1.10ꢀ
.405ꢀ .047ꢀ 1.10ꢀ
.38ꢀ .047ꢀ 1.18ꢀ
1.26ꢀ
.92ꢀ
8-10 .38ꢀ
#14-#10
STR
.77ꢀ
.83ꢀ
6
1/4ꢀ
.47ꢀ
Y8MRB-1(1)
-
-
-
-
7/16ꢀ
5/16ꢀ .53ꢀ
#12-#10
SOL
1/4ꢀ
1/4ꢀ
3/8ꢀ
.47ꢀ
.47ꢀ
.56ꢀ
1/4ꢀ
.44ꢀ
.44ꢀ
.44ꢀ
.44ꢀ
.44ꢀ
.44ꢀ
.81ꢀ
.08ꢀ
.06ꢀ
.06ꢀ
.05ꢀ
.08ꢀ
.08ꢀ
1.24ꢀ
.80ꢀ
1.38ꢀ
1.34ꢀ
.92ꢀ
1.51ꢀ
1.45ꢀ
1.04ꢀ
1.76ꢀ
1.67ꢀ
1.28ꢀ
1.16ꢀ
1.16ꢀ
.71ꢀ
1.73ꢀ
1.43ꢀ
.81ꢀ
1.54ꢀ
1.29ꢀ
.72ꢀ
1.79ꢀ
1.54ꢀ
.93ꢀ
#8 AWG
#8 WELD
37/24
5/16ꢀ .52ꢀ
Y1MR (1)
Y8MRB-1 (1)
Y2MR (1)
MY29-3 (1)
MY29-11 (1)
MRC840 (1)
W8CVT (1) W8CVT (1)
W8CRT (1) W8CRT (1)
X8CRT (1) X8CRT (1)
†
10
3/8ꢀ
1/2ꢀ
.58ꢀ
.71ꢀ
U8CRT (1)
Red 49 7/16ꢀ
#6 SOLID
8-10 .41ꢀ
1/4ꢀ
.45ꢀ
.41ꢀ
Y1MR (1)
MY29-3 (1) W5CVT (1) W5CVT (1)
MY29-11 (1) W5CRT (1) W5CRT (1)
MRC840 (1) X5CRT (1) X5CRT (1)
Y2MR (1) X8CART (1) X8CART (1)
Y644M (1)
.81ꢀ
.81ꢀ
.81ꢀ
.09ꢀ
.09ꢀ
.09ꢀ
#6 AWG
8-10 .41ꢀ
.42ꢀ
U5CRT (1)
Blue
7
7/8ꢀ
YA6CL1-90
YA6CL3-BOX
YA6CL3-45
5/16ꢀ .52ꢀ
.81ꢀ
.07ꢀ
YA6CL3-90
2
* Use P-UADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, P-UADP-1
adapter not required.
†
The MM conductor size listed is for both Class 2 and
Class 5 conductor.
◆ For applications greater than 2000 Volts, consult cable
manufacturer for voltage stress relief instructions.
◆ See tooling section of this catalog for complete tool and
die listings.
2
*** The MM conductor sizes listed are the recommendations
for Class 2 conductor.
BURNDY
Compression
ONE HOLE HYLUG™
B
CODE CONDUCTOR
STANDARD BARREL
(CONTINUED)
Conductor
B
90°
T
T
T
45°
L
L
L
Fig. 3
Fig. 1
Fig. 2
◆ Installation Tooling
Hydraulic
Stud
Figure
Mechanical
Wire
Strip
***
MM
Hole Tongue
Dimensions
(T)
Dieless
(# of crimps)
MD6, OUR840 BCT500HS
MD7-34R
Y35,Y39,Y750
Color Die
2
Catalog Number
YA6CL4-BOX
YA6CL4-45
YA6CL4-90
YA6CL6-BOX
YA6CL6-45
YA6CL6-90
YA5CL-BOX
YA5CL-45
Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
AWG
Size
Width
(B)
(L)
Y500CTHS Y46, BAT35, BAT750 Code Index Length
1.83ꢀ
1.57ꢀ
1.05ꢀ
2.15ꢀ
1.92ꢀ
1.30ꢀ
1.65ꢀ
1.51ꢀ
.81ꢀ
1.74ꢀ
1.44ꢀ
.84ꢀ
1.58ꢀ
1.28ꢀ
.75ꢀ
1.92ꢀ
1.68ꢀ
.96ꢀ
1.92ꢀ
1.68ꢀ
1.08ꢀ
2.20ꢀ
C-7
3/8ꢀ
.63ꢀ
.81ꢀ
.06ꢀ
.12ꢀ
.07ꢀ
.09ꢀ
.09ꢀ
.08ꢀ
.08ꢀ
.06ꢀ
.09ꢀ
.11ꢀ
.11ꢀ
.11ꢀ
.09ꢀ
.10ꢀ
.01ꢀ
.10ꢀ
.09ꢀ
W5CVT (1) W5CVT (1)
W5CRT (1) W5CRT (1)
X5CRT (1) X5CRT (1) UBCABT (1)
X8CART (1) X8CART (1)
Y1MR (1)
MY29-3 (1)
MY29-11 (1)
MRC840 (1)
Y2MR (1)
U5CRT (1)
#6 AWG
Blue
Blue
7
7
7/8ꢀ
7/8ꢀ
1/2ꢀ
1/4ꢀ
1/4ꢀ
.75ꢀ
.44ꢀ
.50ꢀ
.81ꢀ
.81ꢀ
.81ꢀ
.81ꢀ
.81ꢀ
.81ꢀ
.81ꢀ
.88ꢀ
.88ꢀ
.88ꢀ
.88ꢀ
.88ꢀ
.88ꢀ
.88ꢀ
.88ꢀ
W5CRT (1) W5CRT (1)
W5CVT (1) X5CRT (1)
X5CRT (1) W5CVT (1)
Y644M (1)
#5 AWG
U5CRT (1)
YA5CL-90
YA4CL-BOX
YA4CL-45
YA4CL-90
YA4CL1-BOX
YA4CL1-45
YA4CL1-90
YA4CL3-BOX
YA4CL3-45
YA4CL3-90
YA4CL4-BOX
YA4CL4-45
YA4CL4-90
YA4CL6-BOX
YA4CL6-45
YA4CL6-90
YA3CL
8-10 .50ꢀ
5/16ꢀ .58ꢀ
W4CVT (1) W4CVT (1)
W4CRT (1) W4CRT (1)
X4CRT (1) X4CRT (1)
U4CRT (1)
U6CABT (1)
#4 AWG
Gray
8
7/8ꢀ
3/8ꢀ
1/2ꢀ
.58ꢀ
.71ꢀ
Y1MR (1)
2.02ꢀ MY29-3 (1)
1.32ꢀ MY29-11 (1)
1.88ꢀ MRC840 (1)
1.76ꢀ
.98ꢀ
1.88ꢀ
1.55ꢀ
.89ꢀ
# 3 STR
# 2 SOL
YA3CL-45
YA3CL-90
25 5/16ꢀ .55ꢀ
Y2MR (2) W3CRT (1) W3CRT (1)
Y644M (1)
U3CRT (1)
White
9
15/16ꢀ
YA2CL2-BOX
YA2CL2-45
YA2CL2-90
YA2CL-BOX
YA2CL-45
1/4ꢀ
.61ꢀ
1.93ꢀ
1.62ꢀ
1.01ꢀ
2.06ꢀ
1.74ꢀ
1.14ꢀ
2.32ꢀ
2.17ꢀ
1.37ꢀ
1.81ꢀ
1.70ꢀ
.91ꢀ
1.94ꢀ
1.82ꢀ
1.03ꢀ
2.06ꢀ
1.95ꢀ
1.16ꢀ
2.37ꢀ
2.22ꢀ
1.40ꢀ
5/16ꢀ .61ꢀ
W2CVT (1) W2CVT (1)
W2CRT (1) W2CRT (1)
X2CRT (1) X2CRT (1)
YA2CL-90
U2CRT (1) Brown 10 15/16ꢀ
#2 AWG
35
YA2CL4-BOX
YA2CL4-45
YA2CL4-90
YA2CL6-BOX
YA2CL6-45
YA2CL6-90
YA1CL2
YA1CL2-45
YA1CL2-90
YA1CL-BOX
YA1CL-45
3/8ꢀ
1/2ꢀ
1/4ꢀ
.61ꢀ
.73ꢀ
.68ꢀ
Y1MR (1)
5/16ꢀ .68ꢀ
MY29-3 (1) W1CVT (1) W1CVT (1)
MY29-11 (1) W1CRT-1 (1) W1CRT-1 (1)
MRC840 (1) X1CRT-1 (1) X1CRT-1 (1)
Y644M (1)
YA1CL-90
U1CRT-1 (1)
#1 AWG
50
Green 11 15/16ꢀ
U4CABT (1)
YA1CL4-BOX
YA1CL4-45
YA1CL4-90
YA1CL6-BOX
YA1CL6-45
YA1CL6-90
3/8ꢀ
1/2ꢀ
.68ꢀ
.73ꢀ
.88ꢀ
2
*** The MM conductor sizes listed are the recommendations
for Class 2 conductor.
◆ For applications greater than 2000 Volts, consult cable
manufacturer for voltage stress relief instructions.
* Use P-UADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, P-UADP-1
adapter not required.
◆ See tooling section of this catalog for complete tool and die
listings.
BURNDY
Compression
ONE HOLE HYLUG™
B
CODE CONDUCTOR
STANDARD BARREL
(CONTINUED)
B
90°
T
T
T
45°
L
L
L
Fig. 1
Fig. 3
Fig. 2
Conductor
◆ Installation Tooling
Stud
Hole Tongue
Size
Figure
Dimensions
(T)
Mechanical
MD6, OUR840 BCT500HS
MD7-34R
Hydraulic
Wire
Strip
***
Dieless
(# of crimps)
Y35,Y39,Y750
Color Die
2
Catalog Number
YA25L2-BOX
YA25L2-45
YA25L2-90
YA25L4-BOX
YA25L4-45
YA25L4-90
YA25L6-BOX
YA25L6-45
YA25L6-90
YA25L-BOX
YA25L-45
Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
1
2
3
1
2
3
1
2
3
1
2
3
AWG
MM
Width
(B)
(L)
Y500CTHS Y46, BAT35, BAT750 Code Index Length
C-8
1.84ꢀ
1.76ꢀ
.94ꢀ
1/4ꢀ
.75ꢀ
.88ꢀ
.12ꢀ
.12ꢀ
.12ꢀ
.12ꢀ
.12ꢀ
.12ꢀ
.12ꢀ
.12ꢀ
.12ꢀ
2.09ꢀ
2.01ꢀ
1.19ꢀ
2.34ꢀ
2.26ꢀ
1.44ꢀ
1.96ꢀ
1.88ꢀ
1.07ꢀ
1.94ꢀ
1.78ꢀ
.96ꢀ
2.06ꢀ
1.91ꢀ
1.09ꢀ
2.19ꢀ
2.03ꢀ
1.21ꢀ
2.96ꢀ
3/8ꢀ
1/2ꢀ
.75ꢀ
.75ꢀ
.88ꢀ
W25VT (2) W25VT (2)
W25RT (2) W25RT (2)
X25RT (2) X25RT (2)
U25RT (1)
U2CABT (1)
Pink 12 15/16ꢀ
1/0 AWG
.88ꢀ
.88ꢀ
.94ꢀ
.94ꢀ
.94ꢀ
.94ꢀ
.94ꢀ
5/16ꢀ .88ꢀ
YA25L-90
YA26L2-BOX
YA26L2-45
YA26L2-90
YA26L3-BOX
YA26L3-45
YA26L3-90
YA26L-BOX
YA26L-45
1/4ꢀ
.83ꢀ
5/16ꢀ .83ꢀ
3/8ꢀ
3/4ꢀ
1/2ꢀ
5/8ꢀ
.83ꢀ
.96ꢀ
.83ꢀ
.88ꢀ
YA26L-90
YA26L60
W26VT (2) W26VT (2)
W26RT (2) W26RT (2)
2/0 AWG
70
U26RT (1)
Black 13
1ꢀ
YA26L60-45
YA26L60-90
YA26L6-BOX
YA26L6-45
YA26L6-90
YA26L7-BOX
YA26L7-45
YA26L7-90
YA26LNT516
YA27L2-BOX
YA27L2-45
YA27L2-90
YA27L3
YA27L3-45
YA27L3-90
YA27L4-BOX
YA27L4-45
YA27L4-90
YA27L-BOX
YA27L-45
2.77ꢀ MY29-3 (1) X26RT (2) X26RT (2)
1.89ꢀ MY29-11 (1)
2.44ꢀ MRC840 (2)
2.28ꢀ
1.46ꢀ
2.69ꢀ
2.50ꢀ
1.71ꢀ
2.62ꢀ
2.04ꢀ
1.91ꢀ
.99ꢀ
2.16ꢀ
2.03ꢀ
1.12ꢀ
2.29ꢀ
1.91ꢀ
.99ꢀ
Y644M (1)
.94ꢀ
.94ꢀ
.11ꢀ
.13ꢀ
5/16ꢀ .62ꢀ
1/4ꢀ 1ꢀ
1.00ꢀ .13ꢀ
1.00ꢀ .13ꢀ
1.00ꢀ .13ꢀ
5/16ꢀ .91ꢀ
W27VT (2) W27VT (2)
W27RT (2) W27RT (2)
X27RT (3) X27RT (3)
3/0 AWG
U27RT (1)
Orange 14 1-1/16ꢀ
3/8ꢀ
.91ꢀ
2.54ꢀ
2.41ꢀ
1.49ꢀ
1/2ꢀ
3/8ꢀ
.91ꢀ
.76ꢀ
1.00ꢀ .13ꢀ
1.00ꢀ .12ꢀ
YA27L-90
YA27LNT38
YA28L17-BOX
YA28L17-45
YA28L17-90
YA28L2-BOX
YA28L2-45
1
2
3
1
2
2.71ꢀ
2.64ꢀ
1.79ꢀ
1.96ꢀ
1.89ꢀ
5/8ꢀ 1.02ꢀ
.88ꢀ
.14ꢀ
W28VT (2) W28VT (2)
W28RT (2) W28RT (2)
X28RT (3) X28RT (3)
4/0 AWG
U28RT (1)
Purple 15 1-1/8ꢀ
1/4ꢀ 1.02ꢀ
.88ꢀ
.14ꢀ
2
* Use P-UADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, P-UADP-1
adapter not required.
*** The MM conductor sizes listed are the recommendations
for Class 2 conductor.
◆ For applications greater than 2000 Volts, consult cable
manufacturer for voltage stress relief instructions.
◆ See tooling section of this catalog for complete tool and
die listings.
BURNDY
Compression
ONE HOLE HYLUG™
B
CODE CONDUCTOR
STANDARD BARREL
(CONTINUED)
B
90°
T
T
T
45°
L
L
L
Fig. 3
Fig. 1
Fig. 2
Conductor
◆ Installation Tooling
Stud
Hole Tongue
Size Width
Figure
Dimensions
(T)
Mechanical
MD6, OUR840 BCT500HS
MD7-34R
Hydraulic
Wire
Strip
***
MM
Dieless
(# of crimps)
Y35,Y39,Y750
Color Die
2
Catalog Number
YA28L2-90
YA28L3-BOX
YA28L3-45
YA28L3-90
YA28L4-BOX
YA28L4-45
YA28L4-90
YA28L56-BOX
YA28L56-45
YA28L56-90
YA28L-BOX
YA28L-45
Fig #
3
1
2
3
1
2
3
1
2
3
1
2
3
1
1
2
3
1
2
3
1
2
3
1
2
3
AWG
(B)
(L)
Y500CTHS Y46, BAT35, BAT750 Code Index Length
C-9
1/4ꢀ 1.02ꢀ
.88ꢀ
.14ꢀ
1.04ꢀ
2.08ꢀ
2.01ꢀ
1.16ꢀ
2.21ꢀ
5/16ꢀ 1.02ꢀ
.88ꢀ
.14ꢀ
3/8ꢀ 1.02ꢀ
3/4ꢀ 1.05ꢀ
1/2ꢀ 1.02ꢀ
.88ꢀ
.88ꢀ
.14ꢀ
.13ꢀ
2.14ꢀ MY29-3 (1)
1.29ꢀ MY29-11 (1)
2.90ꢀ MRC840 (2)
W28VT (2) W28VT (2)
W28RT (2) W28RT (2)
X28RT (2) X28RT (3)
4/0 AWG
U28RT (1)
Purple 15 1-1/8ꢀ
2.81ꢀ
1.97ꢀ
2.46ꢀ
2.39ꢀ
1.54ꢀ
2.79ꢀ
2.17ꢀ
2.07ꢀ
1.08ꢀ
2.42ꢀ
2.32ꢀ
1.33ꢀ
Y644M (1)
.88ꢀ
.88ꢀ
.14ꢀ
.16ꢀ
YA28L-90
YA28LNT38
YA29L2-BOX
YA29L2-45
YA29L2-90
YA29L4-BOX
YA29L4-45
YA29L4-90
YA29L7-BOX
YA29L7-45
YA29L7-90
YA29LTC78-BOX
YA29LTC78-45
YA29LTC78-90
YA29LNT38
YA29L-BOX
YA29L-45
3/8ꢀ
76ꢀ
1/4ꢀ 1.11ꢀ 1.06ꢀ .16ꢀ
3/8ꢀ 1.11ꢀ 1.06ꢀ .16ꢀ
5/16ꢀ 1.11ꢀ 1.06ꢀ .16ꢀ
7/8ꢀ 1.11ꢀ 1.06ꢀ .14ꢀ
2.30ꢀ MY29-3 (1)
2.20ꢀ MY29-11 (1)
W29VT (2)
W29VT (2)
X29RT (4)
250 kcmil
W29RT (2)
X29RT (4)
U29RT (1)
Yellow 16 1-1/8ꢀ
1.20ꢀ
3.36ꢀ
3.23ꢀ
2.26ꢀ
2.96ꢀ
2.67ꢀ
2.57ꢀ
1.58ꢀ
2.69ꢀ
2.60ꢀ
1.61ꢀ
2.31ꢀ
2.22ꢀ
1.24ꢀ
2.44ꢀ
2.35ꢀ
1.36ꢀ
3.37ꢀ
3.29ꢀ
2.30ꢀ
3.12ꢀ
2.94ꢀ
2.85ꢀ
1.86ꢀ
2.75ꢀ
2.75ꢀ
1.65ꢀ
Y644M (1)
3/8ꢀ
96ꢀ
1.06ꢀ .16ꢀ
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
1
2
3
1
2
3
1/2ꢀ 1.11ꢀ 1.06ꢀ .16ꢀ
1/2ꢀ 1.20ꢀ 1.03ꢀ .16ꢀ
5/16ꢀ 1.20ꢀ 1.03ꢀ .16ꢀ
3/8ꢀ 1.20ꢀ 1.03ꢀ .16ꢀ
7/8ꢀ 1.20ꢀ 1.03ꢀ .16ꢀ
YA29L-90
YA30L-BOX
YA30L-45
YA30L-90
YA30L1-BOX
YA30L1-45
YA30L1-90
YA30L24-BOX
YA30L24-45
YA30L24-90
YA30L27-BOX
YA30L27-45
YA30L27-90
YA30L28-BOX
YA30L7-BOX
YA30L7-45
YA30L7-90
YA31L-BOX
YA31L-45
W30VT (2)
W30VT (2)
U30RT (2)
White 17 1-1/16ꢀ
300 kcmil 150
W30RT (2)
U28ART (2)
Y644M (1)
3/4ꢀ 1.20ꢀ 1.03ꢀ .16ꢀ
5/8ꢀ 1.20ꢀ 1.03ꢀ .16ꢀ
W31VT (2)
W31VT (2)
U31RT (2)
350 kcmil 185 1/2ꢀ 1.29ꢀ 1.06ꢀ .18ꢀ
Red 18 1-3/16ꢀ
W31RT (2)
U29ART (2)
YA31L-90
2
* Use P-UADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, P-UADP-1
adapter not required.
*** The MM conductor sizes listed are the recommendations
for Class 2 conductor.
◆ For applications greater than 2000 Volts, consult cable
manufacturer for voltage stress relief instructions.
◆ See tooling section of this catalog for complete tool and die
listings.
BURNDY
Compression
ONE HOLE HYLUG™
B
B
90°
CODE CONDUCTOR
STANDARD BARREL
(CONTINUED)
T
T
T
45°
L
L
L
Fig. 1
Fig. 2
Fig. 3
Conductor
◆ Installation Tooling
Stud
Hole Tongue
Size
Figure
Dimensions
(T)
Mechanical
MD6, OUR840 BCT500HS
MD7-34R
Hydraulic
Wire
Strip
***
Dieless
(# of crimps)
Y35,Y39,Y750
Color Die
2
Catalog Number
YA31L11
Fig #
1
AWG
MM
Width
(B)
(L)
Y500CTHS Y46, BAT35, BAT750 Code Index Length
2.50ꢀ
2.42ꢀ
1.40ꢀ
4.02ꢀ
4.02ꢀ
3.94ꢀ
3.00ꢀ
3.00ꢀ
1.90ꢀ
3.37ꢀ
3.18ꢀ
3.08ꢀ
1.95ꢀ
2.93ꢀ
2.83ꢀ
1.70ꢀ
2.68ꢀ
2.58ꢀ
1.45ꢀ
3.62ꢀ
3.52ꢀ
2.38ꢀ
3.57ꢀ
3.30ꢀ
2.00ꢀ
3.37ꢀ
3.30ꢀ
2.03ꢀ
4.05ꢀ
3.99ꢀ
2.72ꢀ
2.87ꢀ
2.80ꢀ
1.53ꢀ
3.12ꢀ
3.05ꢀ
1.78ꢀ
3.55ꢀ
3.49ꢀ
2.22ꢀ
3.80ꢀ
3.74ꢀ
2.47ꢀ
3.81ꢀ
3.67ꢀ
2.08ꢀ
3.29ꢀ
3.72ꢀ
3.51ꢀ
2.11ꢀ
C-10
YA31L11-45
YA31L11-90
YA31L36-BOX
YA31L36-45
YA31L36-90
YA31L7-BOX
YA31L7-45
YA31L7-90
YA31LNT38
YA32L-BOX
YA32L-45
2
3
1
2
3
1
2
3
3/8ꢀ 1.29ꢀ 1.06ꢀ .18ꢀ
7/8ꢀ 1.29ꢀ 1.06ꢀ .18ꢀ
5/8ꢀ 1.29ꢀ 1.06ꢀ .18ꢀ
W31VT (2)
W31RT (2)
U31RT (2)
U29ART (2)
350 kcmil 185
W31VT (2)
Red 18 1-3/16ꢀ
3/8ꢀ
96ꢀ
1.06ꢀ .18ꢀ
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
1
2
3
5/8ꢀ 1.38ꢀ 1.19ꢀ .19ꢀ
1/2ꢀ 1.40ꢀ 1.19ꢀ .19ꢀ
3/8ꢀ 1.38ꢀ 1.19ꢀ .19ꢀ
7/8ꢀ 1.40ꢀ 1.19ꢀ .19ꢀ
5/8ꢀ 1.48ꢀ 1.50ꢀ .21ꢀ
5/8ꢀ 1.55ꢀ 1.27ꢀ .23ꢀ
YA32L-90
YA32L1-BOX
YA32L1-45
YA32L1-90
YA32L14-BOX
YA32L14-45
YA32L14-90
YA32LTC78-BOX
YA32LTC78-45
YA32LTC78-90
YA33L-BOX
YA33L-45
400 kcmil
450 kcmil
W32VT (2)
W32RT (2)
U32RT (2)
U30ART (2)
W32VT (2)
W33VT (2)
Blue 19 1-1/4ꢀ
W33VT (2)
W33RT (2)
U33RT (2)
Gray 326 1-9/16ꢀ
YA33L-90
YA34L-BOX
YA34L-45
Y644M (1)
YA34L-90
YA34L20-BOX
YA34L20-45
YA34L20-90
YA34L37-BOX
YA34L37-45
YA34L37-90
YA34L6-BOX
YA34L6-45
YA34L6-90
YA34L8-BOX
YA34L8-45
YA34L8-90
YA34L9-BOX
YA34L9-45
YA34L9-90
YA35L-BOX
YA35L-45
1ꢀ
1.55ꢀ 1.27ꢀ .23ꢀ
3/8ꢀ 1.55ꢀ 1.27ꢀ .23ꢀ
1/2ꢀ 1.55ꢀ 1.27ꢀ .23ꢀ
3/4ꢀ 1.55ꢀ 1.27ꢀ .23ꢀ
7/8ꢀ 1.55ꢀ 1.27ꢀ .23ꢀ
500 kcmil 240
W34VT (2)
W34RT (2)
U34RT (2)
U31ART (2)
W34VT (2)
Brown 20 1-7/16ꢀ
550 kcmil
5/8ꢀ 1.65ꢀ 1.69ꢀ .25ꢀ
1/2ꢀ 1.74ꢀ 1.38ꢀ .27ꢀ
5/8ꢀ 1.74ꢀ 1.38ꢀ .27ꢀ
-
-
-
-
U35RT (2)
U36RT (2)
Yellow 21 1-3/4ꢀ
Green 22 1-3/4ꢀ
YA35L-90
YA36L11-BOX
YA36L-BOX
YA36L-45
600 kcmil 300
YA36L-90
2
◆ For applications greater than 2000 Volts, consult cable
manufacturer for voltage stress relief instructions.
* Use P-UADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, P-UADP-1
adapter not required.
*** The MM conductor sizes listed are the recommendations
for Class 2 conductor.
◆ See tooling section of this catalog for complete tool and
die listings.
BURNDY
Compression
ONE HOLE HYLUG™
B
CODE CONDUCTOR
STANDARD BARREL
(CONTINUED)
B
90°
T
T
T
45°
L
L
L
Fig. 3
Fig. 2
Fig. 1
Conductor
◆ Installation Tooling
Stud
Hole Tongue
Size Width
Figure
Dimensions
(T)
Mechanical
MD6, OUR840 BCT500HS
MD7-34R
Hydraulic
Wire
Strip
***
MM
Dieless
(# of crimps)
Y35,Y39,Y750
Color Die
2
Catalog Number
YA36LTC78-BOX
YA36LTC78-45
YA36LTC78-90
YA37L-BOX
YA37L-45
Fig #
1
2
3
1
2
3
1
1
2
3
1
2
3
1
2
3
AWG
(B)
(L)
Y500CTHS Y46, BAT35, BAT750 Code Index Length
C-11
3.97ꢀ
3.95ꢀ
2.55ꢀ
3.57ꢀ
3.55ꢀ
2.14ꢀ
3.76ꢀ
3.66ꢀ
3.60ꢀ
2.15ꢀ
3.67ꢀ
3.61ꢀ
2.17ꢀ
4.10ꢀ
4.05ꢀ
2.61ꢀ
4.85ꢀ
4.80ꢀ
3.36ꢀ
4.70ꢀ
3.41ꢀ
3.36ꢀ
1.92ꢀ
3.81ꢀ
3.69ꢀ
2.21ꢀ
4.15ꢀ
4.03ꢀ
2.23ꢀ
4.04ꢀ
4.01ꢀ
2.32ꢀ
3.98ꢀ
4.73ꢀ
4.68ꢀ
4.64ꢀ
2.62ꢀ
4.71ꢀ
4.68ꢀ
2.65ꢀ
4.78ꢀ
4.75ꢀ
2.71ꢀ
5.05ꢀ
5.00ꢀ
2.79ꢀ
5.19ꢀ
5.19ꢀ
2.89ꢀ
U36RT (2)
600 kcmil 300 7/8ꢀ 1.74ꢀ 1.38ꢀ .27ꢀ
-
-
-
-
Green 22 1-3/4ꢀ
U32ART (2)
650 kcmil
700 kcmil
5/8ꢀ 1.80ꢀ 1.39ꢀ .27ꢀ
-
-
U37RT (2)
Orange 23 1-15/16ꢀ
YA37L-90
YA37L1-BOX
YA38L-BOX
YA38L-90
YA38L-45
YA39L-BOX
YA39L-45
5/8ꢀ 1.84ꢀ 1.45ꢀ .27ꢀ
5/8ꢀ 1.91ꢀ 1.42ꢀ .27ꢀ
7/8ꢀ 1.91ꢀ 1.42ꢀ .27ꢀ
U38RT (2)
Pink 400 1-15/16ꢀ
YA39L-90
YA39L2-BOX
YA39L2-45
YA39L2-90
YA39L9-BOX
YA39L9-45
YA39L9-90
YA39LNT38
YA39L6-BOX
YA39L6-45
YA39L6-90
YA40L-BOX
YA40L-45
YA40L-90
YA41L-BOX
YA41L-45
YA41L-90
YA44L-BOX
YA44L-45
U39RT (2)
P39RT (2)
**
1
2
3
750 kcmil
-
-
Black 24 1-15/16ꢀ
1-1/4ꢀ 1.91ꢀ 1.42ꢀ .27ꢀ
3/8ꢀ 1.12ꢀ 1.42ꢀ .27ꢀ
1/2ꢀ 1.91ꢀ 1.42ꢀ .27ꢀ
1
2
3
1
2
3
1
2
3
1
2
3
1
1
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
800 kcmil 400 5/8ꢀ 1.98ꢀ 1.42ꢀ .30ꢀ
Y644M (1)
-
-
-
-
P40RT(3)
**
Orange 25 1-15/16ꢀ
850 kcmil
5/8ꢀ 2.01ꢀ 1.88ꢀ .31ꢀ
-
Gold 26 1-15/16ꢀ
5/8ꢀ 2.19ꢀ 1.65ꢀ .33ꢀ
1/2ꢀ 2.49ꢀ 1.65ꢀ .33ꢀ
YA44L-90
1000 kcmil 500
-
-
P44RT(3)
**
White 27 1-15/16ꢀ
YA44L2-BOX
YA44L23-BOX
YA-45L-BOX
YA-45L-45
1ꢀ
2.19ꢀ 1.65ꢀ .33ꢀ
1250 kcmil
1300 kcmil
1500 kcmil
1750 kcmil
2000 kcmil
3/4ꢀ 2.46ꢀ 2.00ꢀ .38ꢀ
3/4ꢀ 2.53ꢀ 2.00ꢀ .39ꢀ
3/4ꢀ 2.69ꢀ 2.00ꢀ .40ꢀ
3/4ꢀ 2.90ꢀ 2.19ꢀ .42ꢀ
-
-
-
-
P45RT(3)
**
Yellow 29 2-1/16ꢀ
YA-45L-90
YA-453L-BOX
YA-453L-45
YA-453L-90
YA46L-BOX
YA46L-45
YA46L-90
YA47L-BOX
YA47L-45
-
Orange 30 2-1/16ꢀ
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
P46RT (3)
Green 31 2-1/16ꢀ
**
-
-
-
-
Gray 33 2-1/4ꢀ
YA47L-90
YA48L-BOX
YA48L-45
3/4ꢀ 3.10ꢀ 2.25ꢀ .46ꢀ
-
-
Brown 34 2-1/4ꢀ
YA48L-90
2
* Use P-UADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, P-UADP-1
adapter not required.
*** The MM conductor sizes listed are the recommendations
for Class 2 conductor.
◆ For applications greater than 2000 Volts, consult cable
manufacturer for voltage stress relief instructions.
◆ See tooling section of this catalog for complete tool and die
listings.
相关型号:
©2020 ICPDF网 联系我们和版权申明