T5100-E-GN-5v [AMPHENOL]
Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low cost package;型号: | T5100-E-GN-5v |
厂家: | Amphenol |
描述: | Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low cost package |
文件: | 总4页 (文件大小:129K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
®
Telaire
T5100 Series
Low-Cost Wall Mount
CO2 Transmitter
The new Telaire T5100 series is a new low cost, high performing CO2 transmitter for the building
controls market. It works seamlessly with building automation systems, and allows you to simply
and effectively control fresh air. Demand-controlled ventilation using CO2 sensors prevents energy
losses from over-ventilation while maintaining indoor air quality.
Features:
•ꢀ Patented, Absorption Infrared Gas sensing
engine provides high accuracy in a compact
low cost package.
•ꢀ Sensors are shipped factory calibrated.
•ꢀ Modern enclosure
•ꢀ Patented ABC Logic™ self-calibration
system eliminates the need for manual
calibration in most applications.
•ꢀ Low-cost
•ꢀ Reliable (20 years of low-cost infrared sensor
manufacturing)
•ꢀ Lifetime CO2 calibration guarantee when
using ABC Logic™.
•ꢀ Available output options:
- Voltage 0-10V or 0-5V (jumper selectable)
- Current 4-20 mA
•ꢀ Mounting plate with two-piece terminal
blocks provide quick, easy wiring.
•ꢀ UIP software compatible for customizations
•ꢀ CE, RoHS, REACH and WEEE compliant
•ꢀ Lifetime calibration warranty
•ꢀ Gas permeable, water resistant CO2
diffusionꢀfilterꢀpreventsꢀparticulateꢀandꢀwaterꢀ
contamination of the sensor.
•ꢀ Locking screw secures cover and sensor to
the mounting bracket for tamper resistance.
•ꢀ Two enclosure sizes for regional acceptance
Amphenol
Advanced Sensors
Controlled Ventilation
Ventilation is an important part of maintaining a
Numerous organizations now require and/or recommend
CO2-based ventilation control in different commercial
HVAC applications. Some utility companies also offer
rebates to building owners for installing CO2 sensors.
comfortable, healthy, productive environment for people.
Improper ventilation can have a negative impact on
occupant health and performance, increase the risk
from litigation, and/or waste energy. Demand-controlled
ventilation using CO2 sensors prevents energy losses
from over-ventilation while maintaining indoor air quality.
The most energy savings potential is in buildings where
occupancyꢀfluctuatesꢀduringꢀaꢀ24-hourꢀperiod.ꢀ
Wallꢀmountꢀsensorsꢀareꢀusedꢀtoꢀcontrolꢀaꢀspecificꢀareaꢀ
such as a conference room, classroom, meeting hall,
etc. The Telaire 5100 Ventostat series are easy to install
and have a clean, modern look that suits most indoor
environments.
T5100ꢀSeriesꢀWallꢀMountꢀSpecifications
Sensing Method
•ꢀ Non-dispersive infrared (NDIR) absorption
•ꢀ Gold-plated optics
Warranty
24 months on mechanical defects
Calibration - lifetime warranty (ABC Logic on.)
•ꢀ Patented ABC Logic self calibration algorithm
Certifications
CE EMC, RoHS, REACH and WEEE compliant
CO2 Measurement Range
0 to 2000 ppm
Signal Update
Every 5 seconds
(0 ppm = 0 V, 4 mA)
CO2 Accuracy
±30 ppm or 3% of the reading shown,whichever is higher*
CO2 Warm-up Time
•ꢀ < 2 minutes (operational)
•ꢀ 10 minutes (maximum accuracy)
Power Supply Requirements
18-30 VAC RMS, 50/60 Hz, or 18 to 42 VDC,
polarity protected
Operating Conditions
•ꢀ 32°F to 122°F (0°C to 50°C)
•ꢀ 0 to 95% RH, non-condensing
*AHRAE — regulation 62 states maximum indoor CO2
level of 1000 ppm
Storage Conditions
-40°F to 158°F (-40°C to 70°C)
Power Consumption
Typical 0.7 W at nominal voltage of 24V AC RMS
Flammability Classification
UL94 5VA
Temperature Dependence
0.2% FS per °C (±0.11% per °F)
Output
Stability
<2% of FS over life of sensor (15 years)
Analog (CO2)
•ꢀ 0 to 5 V, or 0 to 10 V jumper selectable (100 Ω output
impedance)
•ꢀ Or 4 to 20 mA (RL maximum 500 Ω)
•ꢀ Voltage and current outputs are not available
simultaneously
Pressure Dependence
0.135% of reading per mm Hg
*C02 accuracy statement excludes standard gas used for
calibration that has an accuracy of 2%. In addition, there is
a potential digital to analog error of up to 2%.
•ꢀ Digital to analog error ±1%
Accessories
Enclosure Specifications
Sensor Accuracy & Field Calibration
CO2 ABC Logic Self Calibration
T1508 Aspiration Box for Duct Mounting
The Model 1508 is designed for in-duct sampling of CO2
concentrationsꢀatꢀflowꢀratesꢀgreaterꢀthanꢀ400ꢀfpm.ꢀClearꢀ
cover allows for observation of the sensor. They will
accommodate any of the T5100 series, and can be used
forꢀtemperatureꢀandꢀRHꢀwhenꢀfitted.ꢀEnclosureꢀisꢀscrewedꢀ
to the duct with probe inserted into air stream. Air
sampling probe is 1-inch (25.4mm) diameter and 8-inch
(203.2mm) long. Enclosure (ABS plastic) has knockouts
for conduit connection. Note: Wiring penetrations must be
sealed prior to use. CO2 sensor not included.
T5100-LED sensors employ the patented ABC (Automatic
Background Calibration) Logic self-calibration system.
ABC Logic virtually eliminates the need for manual
calibration in applications where the indoor CO2 level
drops to outside levels during unoccupied periods (e.g.
during evening hours). ABC Logic is a special software
routine in the sensor that remembers the background
readings for 14 consecutive evenings, calculates if there
is a sensor drift, and then corrects for it.
With ABC Logic enabled, the sensor will typically reach
its operational accuracy after 25 hours of continuous
operation at a condition that is exposed to ambient
reference levels. Sensors will maintain accuracy
specificationsꢀwithꢀABCꢀLogicꢀenabled,ꢀgivenꢀthatꢀitꢀisꢀ
at least three times in 14 days exposed to the reference
value and this reference value is the lowest concentration
to which the sensor is exposed.
Note: Applies when used in typical indoor ambient air. Consult
Telaire if other gases or corrosive agents are part of the
application environment.
CO2 Calibration Guarantee
Telaire is serious about minimizing maintenance, so each
T5100 sensor comes with a lifetime calibration guarantee.
3.20
81.40
1.01
25.69
T1508 Aspiration Box for Duct Mounting
T1505 Splash Resistant Enclosure
The Model 1505 is designed to protect the T5100
series in damp or wet environments as might occur in
agricultural, industrial or food processing environments.
This enclosure (ABS plastic) is designed to protect the
sensor from dripping or sprayed water. Any wall mount
model of the T5100 series sensor can be installed
inside the enclosure. The transparent cover allows for
viewing of the sensor/display. Four diffusion ports allow
for entry of CO2. Knockouts are provided for conduit
connection. Response time of the sensor is slowed to
approximately 30 minutes to measure a 90% step change
in concentrations. Enclosure is designed to screw directly
to a wall. CO2 sensor not included.
4.58
116.40
T5100 standard enclosure
T5100-EC smaller Euro enclosure
T1552 Outside Air Enclosure
Ventostat UIP Software
The Model 1552 is a rugged weatherproof enclosure
(ABS plastic), designed to allow the T5100 series sensor
to operate in an outdoor environment and/or where
ambient temperatures are below freezing. The 1552 is
ideal for monitoring outside air or CO2 as a surrogate
for combustion fumes in parking garages, tunnels and
loading docks. This enclosure features a temperature
control circuit and internal heaters to maintain the
sensor within its normal operating temperature range,
even if temperatures outside the enclosure are as low
as -20°F (-29°C). Four diffusion ports allow for entry
of CO2. Response time of the sensor is slowed to
approximately 30 minutes to measure a 90% step change
in concentrations. Enclosure is designed to screw directly
to a wall. CO2sensor not included. Power consumption is
24V, 1.5 Amp (max), and includes the T5100 series.
The Ventostat UIP software allows you to modify the
standard settings on the T5100 series products.
Software features:
•ꢀ Altitude adjustment for maximum accuracy
performance
•ꢀ Analog output adjustment
•ꢀ Single point and span gas calibration
•ꢀ Turn on and off ABC Logic™
•ꢀ Graphing and logging of CO2
The software can be used by distributors to make
modificationsꢀtoꢀtheꢀT5100ꢀpriorꢀtoꢀshippingꢀtoꢀtheꢀ
customer,ꢀasꢀwellꢀasꢀtoꢀmakeꢀadjustmentsꢀinꢀtheꢀfield.ꢀTheꢀ
USB cable supplies power to the Ventostat, negating the
need for a separate power supply.
The T2090 UIP software kit is supplied with a USB cable
and software CD.
T1505 Splash Resistant Enclosure and T1552 Outside Air Enclosure
Ordering Information
Examples:
T5100 - 10 V output = 10 V
T5100-E-GN-5v Euro case size, no branding, 5v output
T5100-I output = 4-20 mA
E for Euro case
GN for no brand
5V for 0 -5V
nothing for US case
10V for 0 – 10V
I (for I = 4 - 20 mA)
T5100
—
—
www.telaire.com
www.amphenol-sensors.com
©ꢀ2016ꢀAmphenolꢀCorporation.ꢀAllꢀRightsꢀReserved.ꢀSpecificationsꢀareꢀsubjectꢀtoꢀchangeꢀwithoutꢀnotice.ꢀ
Other company names and product names used in this document are the registered trademarks or
trademarks of their respective owners.
Amphenol
Advanced Sensors
AAS-920-586D - 02/2016
相关型号:
T510005004AB
Silicon Controlled Rectifier, 80A I(T)RMS, 80000mA I(T), 50V V(DRM), 50V V(RRM), 1 Element, TO-83, HERMETIC SEALED, METAL PACKAGE-2
POWEREX
T510005004AQ
Silicon Controlled Rectifier, 80A I(T)RMS, 80000mA I(T), 50V V(DRM), 50V V(RRM), 1 Element, TO-94, HERMETIC SEALED, METAL PACKAGE-3
POWEREX
T510005007AB
Silicon Controlled Rectifier, 80A I(T)RMS, 80000mA I(T), 50V V(DRM), 50V V(RRM), 1 Element, TO-83, HERMETIC SEALED, METAL PACKAGE-2
POWEREX
T510005007AQ
Silicon Controlled Rectifier, 80A I(T)RMS, 80000mA I(T), 50V V(DRM), 50V V(RRM), 1 Element, TO-94, HERMETIC SEALED, METAL PACKAGE-3
POWEREX
T510015004AQ
Silicon Controlled Rectifier, 80A I(T)RMS, 80000mA I(T), 100V V(DRM), 100V V(RRM), 1 Element, TO-94, HERMETIC SEALED, METAL PACKAGE-3
POWEREX
T510015005DH
Silicon Controlled Rectifier, 78.5A I(T)RMS, 100V V(RRM), 1 Element, T51, 3 PIN
POWEREX
T510015006DH
Silicon Controlled Rectifier, 78.5A I(T)RMS, 100V V(RRM), 1 Element, T51, 3 PIN
POWEREX
T510015007DH
Silicon Controlled Rectifier, 78.5A I(T)RMS, 100V V(RRM), 1 Element, T51, 3 PIN
POWEREX
©2020 ICPDF网 联系我们和版权申明