FS4H5000-H-3 [AMPHENOL]

Fiber Optic Connector, Simplex, Plug;
FS4H5000-H-3
型号: FS4H5000-H-3
厂家: Amphenol    Amphenol
描述:

Fiber Optic Connector, Simplex, Plug

连接器
文件: 总4页 (文件大小:379K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
®
GoldRush TFOCA-II  
Fiber Optic Connectors  
Amphenol  
Fiber Systems  
International  
About Amphenol Fiber Systems International  
Amphenol Fiber Systems International (AFSI) designs,  
manufactures, markets, and supports reliable and innovative fiber  
optic interconnect solutions that withstand the harsh  
environments of military, oil & gas, mining and broadcast  
applications. After more than a decade in business, AFSI  
continues to uphold its position as a global leader in fiber optic  
interconnect components and systems such as termini, M28876,  
®
MIL-ST, TFOCA and the TFOCA-II connector, which AFSI  
developed and patented. Altogether, AFSI has delivered millions  
of fiber optic connectors in more than 22 countries. Whenever  
there is a need for superior cost-effective fiber optic systems and  
products that will stand up to demanding operating  
environments, you can rely on AFSI for engineering know-how,  
top-quality products and expert technical support.  
For more information about AFSI, please visit our web site  
at www.fibersystems.com  
Corporate Headquarters  
Amphenol Fiber Systems International. Inc.  
1300 Central Expressway North, Suite 100  
Allen, TX 75013  
Publication: AFSI-TFOCAII GoldRush-D-03.23.05 Specifications subject  
to change without notice. www.fibersystems.com - info@fibersystems.com  
© Copyright Amphenol Fiber Systems International. All rights reserved.  
Phone: 214.547.2400 - 800-472-4225  
Fax: 214.547.9344  
Fiber Optic Solutions  
www.fibersystems.com  
®
GoldRush TFOCA-II  
Fiber Optic Connectors  
Amphenol  
Fiber Systems  
International  
®
®
The Gold Rush TFOCA-II and the Gold Rush TFOCA-III  
connector series makes it easier to retrieve data from the face of  
the longwall. The Gold Rush TFOCA-III connector series  
®
TFOCA-I I Brass Plug  
®
utilizes 1.25mm termini to increase channel density while  
®
retaining reliable Gold Rush TFOCA-II housings. Gold Rush  
®
TFOCA-III incorporates 6 channels into the existing 4-channel  
®
shell size, and 24 channels into the current 12 channel  
TFOCA-I I Brass Panel  
Mount Receptacle  
®
TFOCA-II housings. Leveraging the original connector form  
factor allows users to upgrade their systems easily while  
maintaining the AFSI performance and reliability, and quality.  
®
TFOCA-I I Brass Gland  
Receptacle  
Features and Benefits  
Hermaphroditic Design for Versatility - Enables the  
®
TFOCA-II plug to be daisy chained or unreeled from either  
end of a reel.  
®
About GoldRush TFOCA-II  
Field Repairable Using Existing Parts - Additional  
connector components (other than termini) are not required  
to perform field repair.  
Amphenol Fiber Systems International (AFSI) has designed the  
next generation “longwall communications” deployable fiber  
optic connector. By responding to specific customer needs and  
4-Channel Connector Design - Two fold improvement  
over TFOCA with better optical performance.  
Optional Key Positions - Four key positions  
(1,2,3,universal) available, enabling segregation of mated  
plug/receptacles or plug/plug, through mechanical interface.  
Improved Cable Retention Strength - Designed to meet  
400lb. pull strength while protecting fibers from stress.  
Solid Core Alignment Sleeves - More robust than split  
alignment sleeves  
®
leveraging the family of AFSI TFOCA-II connectors, the Gold  
Rush series of fiber-optic connectors was born. These  
innovative interconnect solutions have become an enabling  
technology for “digital mining.” AFSI’s Gold Rush connectors  
address specific mining requirements for the future of intelligent  
mining.  
®
This revolutionary design enables TFOCA-II connectors to seal  
Removable End Cap - Allows for easy field repair and  
cleaning.  
against high humidity and moisture conditions while allowing full  
axial and orbital movement of the mated ferrule, providing the  
lowest possible insertion loss and back reflection of any  
military style connector.  
Commercial Ceramic Ferrule Technology - Enables  
®
TFOCA-II connector to provision multimode and single  
mode interconnect with a variety of polishes including SPC  
and UPC.  
Available in Stainless Steel and Brass - Allows the  
connector to be used in a variety of applications.  
®
The heart of the TFOCA-II family of deployable fiber optic  
connectors is the TFOCA-II termini, featuring “sealed” free  
®
floating termini.  
Applications  
®
The patented Gold Rush TFOCA-II connector series has been  
designed by AFSI for environmentally harsh conditions of  
Oil, Gas and Geoscience industries  
Industrial  
Mining  
mining. Available in both brass and stainless steel, the Gold Rush  
®
®
TFOCA-II and the Gold Rush TFOCA-III connectors are in  
the final approval and certification stages at the Mine Safety  
Health Administration.  
TFOCA-II and TFOCA-III are registered trademark of Amphenol Amphenol Fiber Systems  
International. TFOCA-II is covered by U.S. Patents 6,305,849; 6,371,660 and 6,357,929  
Fiber Optic Solutions  
www.fibersystems.com  
®
GoldRush TFOCA-II  
Fiber Optic Connectors  
Amphenol  
Fiber Systems  
International  
TFOCA-II® 4-Channel Specifications1  
Parameter  
Typical  
Maximum  
0.75dB  
0.75dB  
-40dB  
Insertion loss (multimode)  
Insertion loss (single mode)  
Back reflection (single mode-UPC polish)  
Back reflection (single mode-APC polish)  
Operating temperature  
Storage temperature  
Mud  
0.30dB  
0.40dB  
-50dB  
-60dB  
-50dB  
-46° C to + 71° C  
-52° C to + 85° C  
5 minute immersion, clean with water (per MIL-C-83526/12 /13 requirements)  
1 meter for 24 hours (Per MIL-C-83526 /12 /13 requirements)  
Immersed and frozen in water for 7 hours (Per MIL-C-83526 /12 /13 requirements)  
MIL-STD-1344, Method 2010, 5 cycles  
Water pressure  
Ice crush/freezing water  
Humidity immersion  
Flammability  
MIL-STD-1344, Method 1012  
Vibration (operational)  
Shock  
MIL-STD-1344, Method 2500.1  
EIA/TIA-455-14, Condition A  
Mating durability  
2,000 cycles per EIA/TIA-455-21  
Cable seal flexing  
100 cycles per MIL-STD-1344, Method 2017, Procedure 1  
1,000 cycles per EIA/TIA-455-36  
Twist  
Cable retention  
400 pounds minimum per EIA/TIA-455-6 (applies to plug and strain relief receptacles)  
EIA/TIA-455-2  
Impact  
Crush resistance  
450 pounds minimum per EIA/TIA-455-26  
EMI shielding (receptacle only)  
> 60dB average H-field effectiveness 15kHz to 15MHz, > 67dB average E-field  
effectiveness 15kHz to 10GHz  
TFOCA-II® 4-Channel Part Numbers  
Product Number  
FS4H5000-X-Y  
FS4H5001-X-Y  
FS4H5002-X-Y  
Product Name  
TFOCA-II® Brass Plug  
TFOCA-II® Brass Panel Mount Receptacle  
TFOCA-II® Brass Gland Receptacle  
X=H Cable Diameter Range .190 - .239  
Y=1 Key Option 1  
Y=2 Key Option 2  
Y=3 Key Option 3  
Y=U Universal Key Option  
X=F Cable Diameter Range .240 - .279  
X=A Cable Diameter Range .280 - .315  
X=B Cable Diameter Range .316 - .346  
X=G Cable Diameter Range .347 - .379  
MTFP1X00Y  
TFOCA-II® Terminus  
Product Number  
MTFP1000  
X=Ferrule Type  
Y=Crimp  
0=Multimode  
0=Multimode  
1=Single mode  
1=Single mode  
Blank=W/O Crimp  
C=With Crimp  
Blank=W/O Crimp  
C=With Crimp  
MTFP1000C  
MTFP1100  
MTFP1100C  
MTFP1150  
MTFP1175  
MTFP0000  
TFOCA-II® Alignment Sleeve, Multimode  
TFOCA-II® Alignment Sleeve, Single mode  
TFOCA-II® Dummy Terminus  
®
TFOCA-I I GoldRush Plug to Plug  
Cable Assembly on Hannay Reel  
For fully warranted and qualified custom cable assemblies utilizing the TFOCA-II®  
product line, please contact Amphenol Fiber Systems International at 800-472-4225  
or email us at info@fibersystems.com  
1. Some parameters qualified to existing TFOCA-II® design  
Fiber Optic Solutions  
www.fibersystems.com  
®
GoldRush TFOCA-II  
Fiber Optic Connectors  
Amphenol  
Fiber Systems  
International  
TFOCA-II® Brass Mount Receptacle  
Panel Cut-out  
TFOCA-II® Brass Panel Mount Receptacle  
.518  
1.195u.005  
MAX  
ALLOW 1.813 FOR WRENCH CLEARENCE  
PANEL THICHNESS .090 MN / .250MAX  
1.40 MAX  
.798  
1.140 +.005  
-.000  
MAX  
.282  
MAX  
1.760 MAX  
1.555 MAX  
TFOCA-II® Brass Gland Receptacle  
0.69  
+
.50 .02  
-
1.40 MAX  
0.90  
+.000  
-.002  
1.748  
1.55 MAX  
AFTER KNURL  
1.998 MAX  
TFOCA-II® Brass Plug  
7.65 MAX LENGTH WITH DUST CAP INSTALLED  
6.35 MAX  
1.30 MAX  
4.80 MAX  
1.555 MAX  
Drawings are not to scale. Measurements are in inches.  
Fiber Optic Solutions  
www.fibersystems.com  

相关型号:

FS4H5000-H-U

Fiber Optic Connector, Simplex, Plug
AMPHENOL

FS4H5001-1

Fiber Optic Connector
AMPHENOL

FS4H5001-H-3

Fiber Optic Connector, Simplex, Receptacle
AMPHENOL

FS4H5002-2

Fiber Optic Connector
AMPHENOL

FS4H5002-B-U

Fiber Optic Connector, Simplex, Receptacle
AMPHENOL

FS4H5002-G-1

Fiber Optic Connector, Simplex, Receptacle
AMPHENOL

FS4H5007-BB1A3

Fiber Optic Connector
AMPHENOL

FS4H5007-BB1A4

Fiber Optic Connector
AMPHENOL

FS4H6000-1-1

Fiber Optic Connector, Simplex, Receptacle
AMPHENOL

FS4H6000-1-2

Fiber Optic Connector, Simplex, Receptacle
AMPHENOL

FS4H6000-1-3

Fiber Optic Connector, Simplex, Receptacle
AMPHENOL

FS4H6000-1-U

Fiber Optic Connector, Simplex, Receptacle
AMPHENOL