BS128HD8VF [AMD]
128 or 64 Megabit (8 M or 4 M x 16-Bit) CMOS 1.8 Volt-only Simultaneous Read/Write, Burst Mode Flash Memory; 128或64兆比特( 8 M或4米×16位) CMOS 1.8伏只同步读/写,突发模式闪存型号: | BS128HD8VF |
厂家: | AMD |
描述: | 128 or 64 Megabit (8 M or 4 M x 16-Bit) CMOS 1.8 Volt-only Simultaneous Read/Write, Burst Mode Flash Memory |
文件: | 总89页 (文件大小:1587K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Am29BDS128H/Am29BDS640H
Data Sheet
RETIRED
PRODUCT
(AM29BDS40H ONLY)
(
The Am29BDS640H has been retired and is not recommended for designs. For new designs,
S29WS064K supersedes Am29BDS640H. Please refer to the S29WS-K family data sheet for speci-
fications and ordering information. The Am29BDS128H is available and is not affected by this revi-
sion.
The following document contains information on Spansion memory products.
Continuity of Specifications
There is no change to this data sheet as a result of offering the device as a Spansion product. Any
changes that have been made are the result of normal data sheet improvement and are noted in the
document revision summary. Future routine revisions will occur when appropriate, and changes will
be noted in a revision summary.
Continuity of Ordering Part Numbers
Spansion continues to support the Am29BDS640H part numbers. To order these products, please
use only the Ordering Part Numbers listed in this document.
For More Information
Please contact your local sales office for additional information about Spansion memory solutions.
Publication Number 27024 Revision B Amendment 3 Issue Date May 10, 2006
THIS PAGE LEFT INTENTIONALLY BLANK.
DATA SHEET
Am29BDS128H/Am29BDS640H
128 or 64 Megabit (8 M or 4 M x 16-Bit)
CMOS 1.8 Volt-only Simultaneous Read/Write, Burst Mode Flash Memory
The Am29BDS640H has been retired and is not recommended for designs. For new designs, S29WS064K supersedes Am29BDS640H. Please refer to the S29WS-K family data sheet for
specifications and ordering information. The Am29BDS128H is available and is not affected by this revision.
DISTINCTIVE CHARACTERISTICS
ARCHITECTURAL ADVANTAGES
HARDWARE FEATURES
■
■
■
Single 1.8 volt read, program and erase (1.65 to 1.95 volt)
Manufactured on 0.13 µm process technology
VersatileIO™ (VIO) Feature
■
Handshaking feature
—
Provides host system with minimum possible latency by
monitoring RDY
—
Reduced Wait-state handshaking option further reduces
initial access cycles required for burst accesses beginning on
even addresses
—
Device generates data output voltages and tolerates data
input voltages as determined by the voltage on the VIO pin
1.8V compatible I/O signals
—
■
■
Hardware reset input (RESET#)
Hardware method to reset the device for reading array data
WP# input
Write protect (WP#) function allows protection of the four
■
Simultaneous Read/Write operation
—
—
Data can be continuously read from one bank while
executing erase/program functions in other bank
Zero latency between read and write operations
Four bank architecture:
—
—
—
highest and four lowest 4 kWord boot sectors, regardless of
sector protect status
128 Mb has 16/48/48/16 Mbit banks
■
Persistent Sector Protection
64 Mb has 8/24/24/8 Mbit banks
—
A command sector protection method to lock combinations of
individual sectors and sector groups to prevent program or
erase operations within that sector
■
Programable Burst Interface
—
—
—
2 Modes of Burst Read Operation
Linear Burst: 8, 16, and 32 words with wrap-around
Continuous Sequential Burst
—
Sectors can be locked and unlocked in-system at VCC level
■
■
Password Sector Protection
■
■
SecSiTM (Secured Silicon) Sector region
—
A sophisticated sector protection method to lock
combinations of individual sectors and sector groups to
prevent program or erase operations within that sector using
a user-defined 64-bit password
—
—
—
Up to 128 words accessible through a command sequence
Up to 64 factory-locked words
Up to 64 customer-lockable words
Sector Architecture
ACC input: Acceleration function reduces programming
time; all sectors locked when ACC = VIL
—
Banks A and D each contain both 4 Kword sectors and 32
Kword sectors; Banks B and C contain ninety-six 32 Kword
sectors
■
■
CMOS compatible inputs, CMOS compatible outputs
Low VCC write inhibit
—
Sixteen 4 Kword boot sectors
Half of the boot sectors are at the top of the address range;
half are at the bottom of address range
SOFTWARE FEATURES
■
■
Minimum 1 million erase cycle guarantee per sector
20-year data retention at 125°C
■
Supports Common Flash Memory Interface (CFI)
■
Software command set compatible with JEDEC 42.4
standards
—
Reliable operation for the life of the system
■
80-ball FBGA package (128 Mb) or 64-ball FBGA (64 Mb)
package
—
Backwards compatible with Am29F and Am29LV families
■
■
Data# Polling and toggle bits
—
Provides a software method of detecting program and erase
operation completion
PERFORMANCE CHARCTERISTICS
■
Read access times at 75/66/54 MHz (CL=30 pF)
Erase Suspend/Resume
—
Burst access times of 9.3/11/13.5 ns at industrial
temperature range
—
Suspends an erase operation to read data from, or program
data to, a sector that is not being erased, then resumes the
erase operation
—
—
Synchronous latency of 49/56/69 ns
Asynchronous random access times of 45/50/55 ns
■
■
Unlock Bypass Program command
■
Power dissipation (typical values, CL = 30 pF)
—
Reduces overall programming time when issuing multiple
program command sequences
—
—
—
—
Burst Mode Read: 10 mA
Simultaneous Operation: 25 mA
Program/Erase: 15 mA
Burst Suspend/Resume
—
Suspends a burst operation to allow system use of the
address and data bus, than resumes the burst at the previous
state
Standby mode: 0.2 µA
Publication# 27024
Rev: B Amendment: 3
Issue Date: May 10, 2006
D A T A S H E E T
GENERAL DESCRIPTION
The Am29BDS128H/Am29BDS640H is a 128 or 64 Mbit, 1.8
Volt-only, simultaneous Read/Write, Burst Mode Flash mem-
ory device, organized as 8,388,608 or 4,194,304 words of 16
bits each. This device uses a single VCC of 1.65 to 1.95 V to
read, program, and erase the memory array. A 12.0-volt VHH
on ACC may be used for faster program performance if de-
sired. The device can also be programmed in standard
EPROM programmers.
The clock polarity feature provides system designers a
choice of active clock edges, either rising or falling. The ac-
tive clock edge initiates burst accesses and determines
when data will be output.
The device is entirely command set compatible with the
JEDEC 42.4 single-power-supply Flash standard. Com-
mands are written to the command register using standard
microprocessor write timing. Register contents serve as in-
puts to an internal state-machine that controls the erase and
programming circuitry. Write cycles also internally latch ad-
dresses and data needed for the programming and erase
operations. Reading data out of the device is similar to read-
ing from other Flash or EPROM devices.
At 75 MHz, the device provides a burst access of 9.3 ns at
30 pF with a latency of 49 ns at 30 pF. At 66 MHz, the device
provides a burst access of 11 ns at 30 pF with a latency of
56 ns at 30 pF. At 54 MHz, the device provides a burst ac-
cess of 13.5 ns at 30 pF with a latency of 69ns at 30 pF. The
device operates within the industrial temperature range of
-40°C to +85°C. The device is offered in FBGA packages.
The Erase Suspend/Erase Resume feature enables the
user to put erase on hold for any period of time to read data
from, or program data to, any sector that is not selected for
erasure. True background erase can thus be achieved. If a
read is needed from the SecSi Sector area (One Time Pro-
gram area) after an erase suspend, then the user must use
the proper command sequence to enter and exit this region.
The Simultaneous Read/Write architecture provides simul-
taneous operation by dividing the memory space into four
banks. The device can improve overall system performance
by allowing a host system to program or erase in one bank,
then immediately and simultaneously read from another
bank, with zero latency. This releases the system from wait-
ing for the completion of program or erase operations.
The hardware RESET# pin terminates any operation in
progress and resets the internal state machine to reading
array data. The RESET# pin may be tied to the system reset
circuitry. A system reset would thus also reset the device,
enabling the system microprocessor to read boot-up firm-
ware from the Flash memory device.
The device is divided as shown in the following table:
Quantity
Bank
128 Mb
64 Mb
8
Size
The host system can detect whether a program or erase op-
eration is complete by using the device status bit DQ7
(Data# Polling) and DQ6/DQ2 (toggle bits). After a program
or erase cycle has been completed, the device automatically
returns to reading array data.
8
4 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
4 Kwords
A
31
96
96
31
8
15
48
48
15
8
B
C
The sector erase architecture allows memory sectors to be
erased and reprogrammed without affecting the data con-
tents of other sectors. The device is fully erased when
shipped from the factory.
D
Hardware data protection measures include a low VCC de-
tector that automatically inhibits write operations during
power transitions. The device also offers two types of data
protection at the sector level. When at VIL, WP# locks the
four highest and four lowest boot sectors.
The VersatileIO™ (VIO) control allows the host system to set
the voltage levels that the device generates at its data out-
puts and the voltages tolerated at its data inputs to the same
voltage level that is asserted on the VIO pin.
The device offers two power-saving features. When ad-
dresses have been stable for a specified amount of time, the
device enters the automatic sleep mode. The system can
also place the device into the standby mode. Power con-
sumption is greatly reduced in both modes.
The device uses Chip Enable (CE#), Write Enable (WE#),
Address Valid (AVD#) and Output Enable (OE#) to control
asynchronous read and write operations. For burst opera-
tions, the device additionally requires Ready (RDY), and
Clock (CLK). This implementation allows easy interface with
minimal glue logic to a wide range of microprocessors/micro-
controllers for high performance read operations.
AMD Flash technology combines years of Flash memory
manufacturing experience to produce the highest levels of
quality, reliability and cost effectiveness. The device electri-
cally erases all bits within a sector simultaneously via
Fowler-Nordheim tunnelling. The data is programmed using
hot electron injection.
The burst read mode feature gives system designers flexibil-
ity in the interface to the device. The user can preset the
burst length and wrap through the same memory space, or
read the flash array in continuous mode.
2
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
TABLE OF CONTENTS
Product Selector Guide . . . . . . . . . . . . . . . . . . . . .5
Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Block Diagram of Simultaneous
Low V Write Inhibit .............................................................. 24
CC
Write Pulse “Glitch” Protection ................................................ 24
Logical Inhibit .......................................................................... 24
Power-Up Write Inhibit ............................................................ 24
Table 8. CFI Query Identification String ......................................... 24
Table 9. System Interface String .................................................... 25
Table 10. Device Geometry Definition ........................................... 25
Table 11. Primary Vendor-Specific Extended Query ..................... 26
Table 12. Am29BDS128H Sector Address Table .......................... 27
Table 13. Am29BDS640H Sector Address Table .......................... 31
Command Definitions . . . . . . . . . . . . . . . . . . . . . 33
Reading Array Data ................................................................ 33
Set Configuration Register Command Sequence ...................33
Figure 3. Synchronous/Asynchronous State Diagram ................... 33
Read Mode Setting ................................................................. 33
Programmable Wait State Configuration ................................ 33
Table 14. Programmable Wait State Settings ................................ 34
Reduced Wait-state Handshaking Option ............................... 34
Table 15. Wait States for Reduced Wait-state Handshaking ........ 34
Standard Handshaking Option ................................................ 35
Table 16. Wait States for Standard Handshaking .......................... 35
Read Mode Configuration ....................................................... 35
Table 17. Read Mode Settings ....................................................... 35
Burst Active Clock Edge Configuration ................................... 35
RDY Configuration .................................................................. 35
Table 18. Configuration Register ................................................... 36
Reset Command ..................................................................... 36
Autoselect Command Sequence ............................................ 36
Table 19. Autoselect Data .............................................................. 37
Enter SecSi™ Sector/Exit SecSi Sector
Operation Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Connection Diagram . . . . . . . . . . . . . . . . . . . . . . . .7
Special Handling Instructions for FBGA Package .................... 8
Input/Output Descriptions . . . . . . . . . . . . . . . . . . .9
Logic Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Ordering Information . . . . . . . . . . . . . . . . . . . . . .10
Device Bus Operations . . . . . . . . . . . . . . . . . . . . .11
Table 1. Device Bus Operations ....................................................11
Requirements for Asynchronous Read
Operation (Non-Burst) ............................................................ 11
Requirements for Synchronous (Burst) Read Operation ........ 11
8-, 16-, and 32-Word Linear Burst with Wrap Around ............ 12
Table 2. Burst Address Groups .......................................................12
Burst Suspend/Resume .......................................................... 12
Configuration Register ............................................................ 13
Reduced Wait-state Handshaking Option .............................. 13
Simultaneous Read/Write Operations with Zero Latency ....... 13
Writing Commands/Command Sequences ............................ 13
Accelerated Program Operation ............................................. 14
Autoselect Mode ..................................................................... 14
Table 3. Autoselect Codes (High Voltage Method) ........................15
Table 4. Am29BDS128H Boot Sector/Sector Block Addresses for Pro-
tection/Unprotection ........................................................................16
Table 5. Am29BDS640H Boot Sector/Sector Block Addresses for Pro-
tection/Unprotection ........................................................................17
Sector/Sector Block Protection and Unprotection .................. 17
Sector Protection .................................................................... 17
Selecting a Sector Protection Mode ....................................... 17
Persistent Sector Protection ................................................... 18
Persistent Protection Bit (PPB) ............................................... 18
Persistent Protection Bit Lock (PPB Lock) ............................. 18
Dynamic Protection Bit (DYB) ................................................ 18
Table 6. Sector Protection Schemes ...............................................19
Persistent Sector Protection Mode Locking Bit ...................... 19
Password Protection Mode ..................................................... 19
Password and Password Mode Locking Bit ........................... 20
64-bit Password ...................................................................... 20
Persistent Protection Bit Lock ................................................. 20
High Voltage Sector Protection .............................................. 20
Standby Mode ........................................................................ 20
Automatic Sleep Mode ........................................................... 21
RESET#: Hardware Reset Input ............................................. 21
Output Disable Mode .............................................................. 21
Figure 1. Temporary Sector Unprotect Operation........................... 21
Figure 2. In-System Sector Protection/
Command Sequence .............................................................. 37
Program Command Sequence ............................................... 37
Unlock Bypass Command Sequence ..................................... 37
Figure 4. Program Operation ......................................................... 38
Chip Erase Command Sequence ........................................... 38
Sector Erase Command Sequence ........................................ 38
Erase Suspend/Erase Resume Commands ........................... 39
Figure 5. Erase Operation.............................................................. 40
Password Program Command ................................................ 40
Password Verify Command .................................................... 40
Password Protection Mode Locking Bit Program Command .. 40
Persistent Sector Protection Mode Locking Bit Program Com-
mand ....................................................................................... 40
SecSi Sector Protection Bit Program Command ....................41
PPB Lock Bit Set Command ................................................... 41
DYB Write Command ............................................................. 41
Password Unlock Command .................................................. 41
Figure 6. PPB Program Algorithm.................................................. 42
PPB Program Command ........................................................ 43
All PPB Erase Command ........................................................ 43
Figure 7. PPB Erase Algorithm ...................................................... 44
DYB Write Command ............................................................. 45
PPB Status Command ............................................................ 45
PPB Lock Bit Status Command .............................................. 45
DYB Status Command ............................................................ 45
Command Definitions ............................................................. 46
Table 20. Memory Array Command Definitions ............................ 46
Table 21. Sector Protection Command Definitions ....................... 47
Sector Unprotection Algorithms ...................................................... 22
SecSi™ (Secured Silicon) Sector
Flash Memory Region ............................................................ 23
Factory-Locked Area (64 words) ............................................ 23
Table 7. SecSiTM Sector Addresses ...............................................23
Customer-Lockable Area (64 words) ...................................... 23
SecSi Sector Protection Bits ................................................... 23
Hardware Data Protection ...................................................... 23
Write Protect (WP#) ................................................................ 24
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
3
D A T A S H E E T
cess................................................................................................ 63
Write Operation Status . . . . . . . . . . . . . . . . . . . . .48
DQ7: Data# Polling ................................................................. 48
Figure 8. Data# Polling Algorithm ................................................... 48
DQ6: Toggle Bit I .................................................................... 49
Figure 9. Toggle Bit Algorithm......................................................... 50
DQ2: Toggle Bit II ................................................................... 50
Table 22. DQ6 and DQ2 Indications ...............................................51
Reading Toggle Bits DQ6/DQ2 .............................................. 51
DQ5: Exceeded Timing Limits ................................................ 51
DQ3: Sector Erase Timer ....................................................... 51
Table 23. Write Operation Status ....................................................52
Absolute Maximum Ratings . . . . . . . . . . . . . . . . .53
Figure 10. Maximum Negative Overshoot Waveform ..................... 53
Figure 11. Maximum Positive Overshoot Waveform....................... 53
Operating Ranges . . . . . . . . . . . . . . . . . . . . . . . . 53
DC Characteristics . . . . . . . . . . . . . . . . . . . . . . . .54
CMOS Compatible . . . . . . . . . . . . . . . . . . . . . . . . .54
Test Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . .55
Figure 12. Test Setup...................................................................... 55
Table 24. Test Specifications ..........................................................55
Key to Switching Waveforms . . . . . . . . . . . . . . . 55
Switching Waveforms . . . . . . . . . . . . . . . . . . . . . 55
Figure 13. Input Waveforms and Measurement Levels .................. 55
AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . .56
Figure 27. Standard Handshake Burst Suspend at Address 3Fh (Start-
ing Address 3Dh or Earlier)............................................................ 64
Figure 28. Standard Handshake Burst Suspend at Address 3Eh/3Fh
(Without a Valid Initial Access)....................................................... 64
Figure 29. Standard Handshake Burst Suspend at Address 3Eh/3Fh
(with 1 Access CLK)....................................................................... 65
Figure 30. Read Cycle for Continuous Suspend............................ 65
Asynchronous Mode Read .................................................... 66
AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . 67
Figure 31. Asynchronous Mode Read with Latched Addresses .... 67
Figure 32. Asynchronous Mode Read............................................ 67
Figure 33. Reset Timings............................................................... 68
Erase/Program Operations ..................................................... 69
Figure 34. Asynchronous Program Operation Timings: AVD# Latched
Addresses ...................................................................................... 70
Figure 35. Asynchronous Program Operation Timings: WE# Latched
Addresses ...................................................................................... 71
Figure 36. Synchronous Program Operation Timings: WE# Latched
Addresses ...................................................................................... 72
Figure 37. Synchronous Program Operation Timings: CLK Latched
Addresses ...................................................................................... 73
Figure 38. Chip/Sector Erase Command Sequence...................... 74
Figure 39. Accelerated Programming Timing................................. 75
Figure 40. Data# Polling Timings (During Embedded Algorithm) .. 76
Figure 41. Toggle Bit Timings (During Embedded Algorithm)........ 76
Figure 42. Synchronous Data Polling Timings/Toggle Bit Timings 77
Figure 43. DQ2 vs. DQ6................................................................. 77
Temporary Sector Unprotect .................................................. 78
Figure 44. Temporary Sector Unprotect Timing Diagram .............. 78
Figure 45. Sector/Sector Block Protect and
V
Power-up ......................................................................... 56
CC
Figure 14. VCC Power-up Diagram ................................................. 56
CLK Characterization ............................................................. 56
Figure 15. CLK Characterization..................................................... 56
Synchronous/Burst Read ....................................................... 57
Figure 16. CLK Synchronous Burst Mode Read (rising active CLK) ...
.........................................................................................................58
Figure 17. CLK Synchronous Burst Mode Read (Falling Active Clock)
.........................................................................................................58
Figure 18. Synchronous Burst Mode Read..................................... 59
Figure 19. 8-word Linear Burst with Wrap Around.......................... 59
Figure 20. Linear Burst with RDY Set One Cycle Before Data ....... 60
Figure 21. Reduced Wait-state Handshake Burst Suspend/Resume at
an Even Address............................................................................. 61
Figure 22. Reduced Wait-state Handshake Burst Suspend/Resume at
an Odd Address .............................................................................. 61
Figure 23. Reduced Wait-state Handshake Burst Suspend/Resume at
Address 3Eh (or Offset from 3Eh)................................................... 62
Figure 24. Reduced Wait-state Handshake Burst Suspend/Resume at
Address 3Fh (or Offset from 3Fh by a Multiple of 64)..................... 62
Figure 25. Standard Handshake Burst Suspend Prior to Initial Access
.........................................................................................................63
Figure 26. Standard Handshake Burst Suspend at or after Initial Ac-
Unprotect Timing Diagram ............................................................. 79
Figure 46. Latency with Boundary Crossing .................................. 80
Figure 47. Latency with Boundary Crossing
into Program/Erase Bank............................................................... 81
Figure 48. Example of Wait States Insertion.................................. 82
Figure 49. Back-to-Back Read/Write Cycle Timings...................... 83
Erase and Programming Performance . . . . . . . 84
BGA Ball Capacitance . . . . . . . . . . . . . . . . . . . . . 84
Data Retention. . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Physical Dimensions . . . . . . . . . . . . . . . . . . . . . . 85
VBB080—80-ball Fine-Pitch Ball Grid Array (BGA) 11.5 x
9 mm Package ........................................................................ 85
VBD064—64-ball Fine-Pitch Ball Grid Array (BGA) 9 x
8 mm Package ........................................................................ 86
Revision Summary . . . . . . . . . . . . . . . . . . . . . . . . 87
4
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
PRODUCT SELECTOR GUIDE
Part Number
Am29BDS128H/Am29BDS640H
Burst Frequency
66 MHz
E8, E9
54 MHz
D8, D9
Speed Option
VCC, VIO = 1.65 – 1.95 V
Max Initial Synchronous Access Time, ns (TIACC
)
56
69
Reduced Wait-state Handshaking; Even Address
Max Initial Synchronous Access Time, ns (TIACC
Reduced Wait-state Handshaking; Odd Address; or Standard Handshaking
Max Burst Access Time, ns (TBACC
Max Asynchronous Access Time, ns (TACC
Max CE# Access Time, ns (TCE
Max OE# Access Time, ns (TOE
)
71
11
87.5
13.5
)
)
50
55
)
)
11
13.5
Note: Speed Options ending in “8” indicate the “reduced wait-state handshaking” option, which speeds initial synchronous
accesses for even addresses. Speed Options ending in “9” indicate the “standard handshaking” option. See the AC
Characteristics section of this data sheet for full specifications.
BLOCK DIAGRAM
VCC
DQ15–DQ0
VSS
VIO
RDY
Buffer
RDY
Erase Voltage
Generator
Input/Output
Buffers
WE#
State
Control
RESET#
WP#
Command
Register
ACC
PGM Voltage
Generator
Data
Latch
Chip Enable
Output Enable
Logic
CE#
OE#
Y-Decoder
Y-Gating
VCC
Detector
Timer
Cell Matrix
X-Decoder
Burst
State
Control
Burst
Address
Counter
AVD#
CLK
Amax–A0
Note: Amax = A22 (128 Mb) or A21 (64 Mb)
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
5
D A T A S H E E T
BLOCK DIAGRAM OF SIMULTANEOUS
OPERATION CIRCUIT
V
CC
V
SS
V
IO
Bank A Address
DQ15–DQ0
Bank A
Amax–A0
X-Decoder
OE#
Bank B Address
DQ15–DQ0
Bank B
WP#
ACC
X-Decoder
Amax–A0
STATE
CONTROL
&
COMMAND
REGISTER
RESET#
WE#
DQ15–DQ0
Status
CE#
AVD#
RDY
Control
Amax–A0
DQ15–DQ0
X-Decoder
Bank C
DQ15–DQ0
Bank C Address
Amax –A0
Amax –A0
X-Decoder
Bank D
Bank D Address
DQ15–DQ0
6
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
CONNECTION DIAGRAM
80-ball Fine-Pitch Ball Grid Array
Top View, Balls Facing Down
(Am29BDS128H only)
C8
D8
E8
F8
G8
H8
J8
K8
L8
M8
NC
A8
B8
NC
NC
NC
NC
A22
NC
VIO
VSS
NC
NC
NC
A7
B7
C7
D7
E7
F7
G7
H7
J7
K7
L7
M7
NC
VSS
NC
NC
NC
A13
A12
A14
A15
A16
NC
DQ15
C6
A9
D6
A8
E6
F6
G6
H6
J6
K6
A10
A11
DQ7
DQ14
DQ13
DQ6
C5
D5
E5
F5
G5
H5
J5
K5
VCC
WE# RESET#
A21
A19
DQ5
DQ12
DQ4
C4
D4
E4
F4
G4
H4
J4
K4
RDY
ACC
A18
A20
DQ2
DQ10
DQ11
DQ3
C3
A7
D3
E3
A6
F3
A5
G3
H3
J3
K3
A17
DQ0
DQ8
DQ9
DQ1
C2
A3
D2
A4
E2
A2
F2
A1
G2
A0
H2
J2
K2
L2
M2
NC
A2
B2
VSS
CE#
OE#
NC
NC
NC
J1
A1
B1
C1
D1
E1
F1
G1
H1
K1
L1
M1
NC
NC
NC
NC
VCC
CLK
WP#
AVD#
VIO
VSS
NC
NC
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
7
D A T A S H E E T
64-ball Fine-Pitch Ball Grid Array
Top View, Balls Facing Down
(Am29BDS640H only)
A8
B8
C8
D8
E8
F8
G8
NC
H8
NC
NC
NC
NC
VIO
VSS
NC
A7
B7
C7
D7
E7
F7
G7
H7
VSS
A13
A12
A14
A15
A16
NC
DQ15
A6
A9
B6
A8
C6
D6
E6
F6
G6
H6
A10
A11
DQ7
DQ14
DQ13
DQ6
A5
B5
C5
D5
E5
F5
G5
H5
VCC
WE# RESET#
A21
A19
DQ5
DQ12
DQ4
A4
B4
C4
D4
E4
F4
G4
H4
RDY
ACC
A18
A20
DQ2
DQ10
DQ11
DQ3
A3
A7
B3
C3
A6
D3
A5
E3
F3
G3
H3
A17
DQ0
DQ8
DQ9
DQ1
A2
A3
B2
A4
C2
A2
D2
A1
E2
A0
F2
G2
H2
VSS
CE#
OE#
G1
A1
B1
C1
D1
E1
F1
H1
NC
VCC
CLK
WP#
AVD#
VIO
VSS
NC
Flash memory devices in FBGA packages may be
damaged if exposed to ultrasonic cleaning methods.
The package and/or data integrity may be compro-
mised if the package body is exposed to temperatures
above 150°C for prolonged periods of time.
Special Handling Instructions for FBGA
Package
Special handling is required for Flash Memory products
in FBGA packages.
8
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
INPUT/OUTPUT DESCRIPTIONS
Amax–A0
=
Address inputs
Amax = A22 (128 Mb) or A21 (64 Mb)
AVD#
=
Address Valid input. Indicates to
device that the valid address is
present on the address inputs
(Amax–A0).
DQ15–DQ0 = Data input/output
CE#
OE#
WE#
=
Chip Enable input. Asynchronous
relative to CLK for the Burst mode.
Low = for asynchronous mode,
indicates valid address; for burst
mode, causes starting address to be
latched.
=
Output Enable input. Asynchronous
relative to CLK for the Burst mode.
=
=
Write Enable input.
High = device ignores address inputs
V
V
V
Device Power Supply
(1.65 – 1.95 V).
RESET#
WP#
=
=
Hardware reset input. Low = device
resets and returns to reading array
data
CC
=
Input & Output Buffer Power Supply
(1.65 – 1.95 V).
IO
Hardware write protect input. At V ,
IL
disables program and erase functions
in the four highest and four lowest
=
=
=
Ground
SS
NC
No Connect; not connected internally
Ready output;
sectors. At V , does not protect any
IH
sectors.
RDY
ACC
=
At V , accelerates programming;
automatically places device in unlock
HH
In Synchronous Mode, indicates the
status of the Burst read.
bypass mode. At V , locks all sectors.
IL
Low = data invalid. High = data valid.
Should be at V for all other
IH
conditions.
In Asynchronous Mode, indicates the
status of the internal program and
erase function.
LOGIC SYMBOL
Low = program/erase in progress.
23 or 22
High Impedance = program/erase
completed.
Amax–A0
16
DQ15–DQ0
CLK
WP#
CLK
=
CLK is not required in asynchronous
mode. In burst mode, after the initial
word is output, subsequent active
edges of CLK increment the internal
address counter.
ACC
CE#
OE#
WE#
RDY
RESET#
AVD#
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
9
D A T A S H E E T
ORDERING INFORMATION
The order number (Valid Combination) is formed by the following:
Am29BDS 128 VK
H
E
8
I
TEMPERATURE RANGE
Industrial (–40°C to +85°C)
I
=
PACKAGE TYPE
VK = 80-Ball Fine-Pitch Ball Grid Array (BGA)
0.80 mm pitch, 11.5 x 9 mm package (VBB080)
VF = 80-Ball Fine-Pitch Ball Grid Array (BGA)
0.80 mm pitch, 11.5 x 9mm, Pb-free Package (VBB080)
VM = 64-Ball Fine-Pitch Ball Grid Array (BGA)
0.80 mm pitch, 8 X 9 mm package (VBD064)
V
8
9
AND HANDSHAKING OPTIONS
IO
=
=
VIO = 1.8 V, reduced wait-state handshaking enabled
VIO = 1.8 V, standard handshaking
SPEED
E
D
=
=
66 MHz
54 MHz
PROCESS TECHNOLOGY
0.13 µm
H
=
DENSITY
128 = 128 Mbit (8 M x 16-bit)
64 64 Mbit (4 M x 16-bit)
=
DEVICE FAMILY
Am29BDS
CMOS Flash Memory, Simultaneous Read/Write,
Burst Mode Flash Memory, 1.8 Volt-only Read, Program, and Erase
Valid Combinations
Burst Frequency
Order Number
Package Marking
BS128HE8V
BS128HE9V
BS128HD8V
BS128HD9V
BS128HE8VF
BS128HE9VF
BS128HD8VF
BS128HD9VF
BS640HE8V
BS640HE9V
BS640HD8V
BS640HD9V
(MHz)
Density
Am29BDS128HE8
Am29BDS128HE9
Am29BDS128HD8
Am29BDS128HD9
Am29BDS128HE8
Am29BDS128HE9
Am29BDS128HD8
Am29BDS128HD9
Am29BDS640HE8
Am29BDS640HE9
Am29BDS640HD8
Am29BDS640HD9
66
VKI
VFI
VMI
54
66
54
66
54
128 Mbit
64 Mbit
Valid Combinations
Valid Combinations list configurations planned to be supported in vol-
ume for this device. Consult the local AMD sales office to confirm avail-
ability of specific valid combinations and to check on newly released
combinations.
10
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
DEVICE BUS OPERATIONS
This section describes the requirements and use of the
device bus operations, which are initiated through the
internal command register. The command register
itself does not occupy any addressable memory loca-
tion. The register is composed of latches that store the
commands, along with the address and data informa-
tion needed to execute the command. The contents of
the register serve as inputs to the internal state
machine. The state machine outputs dictate the func-
tion of the device. Table 1 lists the device bus opera-
tions, the inputs and control levels they require, and the
resulting output. The following subsections describe
each of these operations in further detail.
Table 1. Device Bus Operations
CLK
(See
Operation
CE#
L
OE#
L
WE#
H
Amax–0
Addr In
Addr In
Addr In
Addr In
HIGH Z
HIGH Z
DQ15–0 RESET# Note) AVD#
Asynchronous Read - Addresses Latched
Asynchronous Read - Addresses Steady State
Asynchronous Write
I/O
I/O
H
H
H
H
H
L
X
X
X
L
L
H
L
L
L
H
L
I/O
Synchronous Write
L
H
L
I/O
Standby (CE#)
H
X
X
X
HIGH Z
HIGH Z
X
X
X
X
Hardware Reset
X
X
Burst Read Operations
Load Starting Burst Address
L
L
X
L
H
H
H
H
Addr In
HIGH Z
HIGH Z
HIGH Z
X
H
H
H
L
Advance Burst to next address with
appropriate Data presented on the Data Bus
Burst
Data Out
H
X
X
Terminate current Burst read cycle
H
X
X
X
HIGH Z
HIGH Z
Terminate current Burst read cycle via
RESET#
X
Terminate current Burst read cycle and start
new Burst read cycle
L
X
H
HIGH Z
I/O
H
Legend: L = Logic 0, H = Logic 1, X = Don’t Care, S = Stable Logic 0 or 1 but no transitions.
Note: Default active edge of CLK is the rising edge.
The internal state machine is set for reading array data
in asynchronous mode upon device power-up, or after
a hardware reset. This ensures that no spurious alter-
ation of the memory content occurs during the power
transition.
Requirements for Asynchronous Read
Operation (Non-Burst)
To read data from the memory array, the system must
first assert a valid address on Amax–A0, while driving
AVD# and CE# to V . WE# should remain at V . The
IL
IH
rising edge of AVD# latches the address. The data will
appear on DQ15–DQ0. Since the memory array is
divided into four banks, each bank remains enabled for
read access until the command register contents are
altered.
Requirements for Synchronous (Burst)
Read Operation
The device is capable of continuous sequential burst
operation and linear burst operation of a preset length.
When the device first powers up, it is enabled for asyn-
chronous read operation.
Address access time (t
) is equal to the delay from
ACC
stable addresses to valid output data. The chip enable
Prior to entering burst mode, the system should deter-
mine how many wait states are desired for the initial
access time (t ) is the delay from the stable
CE
addresses and stable CE# to valid data at the outputs.
word (t
) of each burst access, what mode of burst
The output enable access time (t ) is the delay from
IACC
OE
operation is desired, which edge of the clock will be the
the falling edge of OE# to valid data at the output.
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
11
D A T A S H E E T
active clock edge, and how the RDY signal will transi-
8-, 16-, and 32-Word Linear Burst with Wrap Around
tion with valid data. The system would then write the
configuration register command sequence. See “Set
Configuration Register Command Sequence” section
on page 33 and “Command Definitions” section on
page 33 for further details.
The remaining three modes are of the linear wrap
around design, in which a fixed number of words are
read from consecutive addresses. In each of these
modes, the burst addresses read are determined by
the group within which the starting address falls. The
groups are sized according to the number of words
read in a single burst sequence for a given mode (see
Table 2.)
Once the system has written the “Set Configuration
Register” command sequence, the device is enabled
for synchronous reads only.
The initial word is output t
the first CLK cycle. Subsequent words are output t
after the active edge of
IACC
Table 2. Burst Address Groups
BACC
after the active edge of each successive clock cycle,
which automatically increments the internal address
counter. Note that the device has a fixed internal
address boundary that occurs every 64 words, starting
at address 00003Fh. During the time the device is out-
putting data at this fixed internal address boundary
(address 00003Fh, 00007Fh, 0000BFh, etc.), a two
cycle latency occurs before data appears for the next
address (address 000040h, 000080h, 0000C0h, etc.).
The RDY output indicates this condition to the system
by pulsing low. For standard handshaking devices,
there is no two cycle latency between 3Fh and 40h (or
offset from these values by a multiple of 64) if the
latched address was 3Eh or 3Fh or offset from these
values by a multiple of 64). See Figure 46, “Latency
with Boundary Crossing,” on page 80.
Mode
8-word
16-word
32-word
Group Size Group Address Ranges
8 words
16 words
32 words
0-7h, 8-Fh, 10-17h,...
0-Fh, 10-1Fh, 20-2Fh,...
00-1Fh, 20-3Fh, 40-5Fh,...
As an example: if the starting address in the 8-word
mode is 39h, the address range to be read would be
38-3Fh, and the burst sequence would be
39-3A-3B-3C-3D-3E-3F-38h-etc. The burst sequence
begins with the starting address written to the device,
but wraps back to the first address in the selected
group. In a similar fashion, the 16-word and 32-word
Linear Wrap modes begin their burst sequence on the
starting address written to the device, and then wrap
back to the first address in the selected address group.
Note that in these three burst read modes the
address pointer does not cross the boundary that
occurs every 64 words; thus, no wait states are
inserted (except during the initial access).
For reduced wait-state handshaking devices, if the
address latched is 3Eh or 3Fh (or offset from these
values by a multiple of 64) two additional cycle latency
occurs prior to the initial access and the two cycle
latency between 3Fh and 40h (or offset from these
values by a multiple of 64) will not occur.
The RDY pin indicates when data is valid on the bus.
The devices can wrap through a maximum of 128
words of data (8 words up to 16 times, 16 words up to
8 times, or 32 words up to 4 times) before requiring a
new synchronous access (latching of a new address).
The device will continue to output sequential burst
data, wrapping around to address 000000h after it
reaches the highest addressable memory location,
until the system drives CE# high, RESET# low, or
AVD# low in conjunction with a new address. See
Table 1, “Device Bus Operations,” on page 11.
Burst Suspend/Resume
The Burst Suspend/Resume feature allows the system
to temporarily suspend a synchronous burst operation
during the initial access (before data is available) or
after the device is outputting data. When the burst
operation is suspended, any previously latched internal
data and the current state are retained.
If the host system crosses the bank boundary while
reading in burst mode, and the device is not program-
ming or erasing, a two-cycle latency will occur as
described above in the subsequent bank. If the host
system crosses the bank boundary while the device is
programming or erasing, the device will provide read
status information. The clock will be ignored. After the
host has completed status reads, or the device has
completed the program or erase operation, the host
can restart a burst operation using a new address and
AVD# pulse.
Burst Suspend requires CE# to be asserted, WE#
de-asserted, and the initial address latched by AVD# or
the CLK edge. Burst Suspend occurs when OE# is
de-asserted. See Figure 21, “Reduced Wait-state
Handshake Burst Suspend/Resume at an Even
Address,” on page 61, Figure 22, “Reduced Wait-state
Handshake Burst Suspend/Resume at an Odd
Address,” on page 61, Figure 23, “Reduced Wait-state
Handshake Burst Suspend/Resume at Address 3Eh
(or Offset from 3Eh),” on page 62, Figure 24, “Reduced
Wait-state Handshake Burst Suspend/Resume at
If the clock frequency is less than 6 MHz during a burst
mode operation, additional latencies will occur. RDY
indicates the length of the latency by pulsing low.
12
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
Address 3Fh (or Offset from 3Fh by a Multiple of 64),”
Simultaneous Read/Write Operations with
Zero Latency
on page 62, Figure 25, “Standard Handshake Burst
Suspend Prior to Initial Access,” on page 63, Figure 26,
“Standard Handshake Burst Suspend at or after Initial
Access,” on page 63, Figure 27, “Standard Handshake
Burst Suspend at Address 3Fh (Starting Address 3Dh
or Earlier),” on page 64, Figure 28, “Standard Hand-
shake Burst Suspend at Address 3Eh/3Fh (Without a
Valid Initial Access),” on page 64, and Figure 29, “Stan-
dard Handshake Burst Suspend at Address 3Eh/3Fh
(with 1 Access CLK),” on page 65.
This device is capable of reading data from one bank of
memory while programming or erasing in another bank
of memory. An erase operation may also be suspended
to read from or program to another location within the
same bank (except the sector being erased).
Figure 49, “Back-to-Back Read/Write Cycle Timings,”
on page 83 shows how read and write cycles may be
initiated for simultaneous operation with zero latency.
Refer to the DC Characteristics table for
read-while-program and read-while-erase current
specifications.
Burst plus Burst Suspend should not last longer than
t
without re-latching an address or crossing an
RCC
address boundary. To resume the burst access, OE#
must be re-asserted. The next active CLK edge will
resume the burst sequence where it had been sus-
pended. See Figure 30, “Read Cycle for Continuous
Suspend,” on page 65.
Writing Commands/Command Sequences
The device has the capability of performing an asyn-
chronous or synchronous write operation. While the
device is configured in Asynchronous read it is able to
perform Asynchronous write operations only. CLK is
ignored in the Asynchronous programming mode.
When in the Synchronous read mode configuration, the
device is able to perform both Asynchronous and Syn-
chronous write operations. CLK and WE# address
latch is supported in the Synchronous programming
mode. During a synchronous write operation, to write a
command or command sequence (which includes pro-
gramming data to the device and erasing sectors of
The RDY pin is only controlled by CE#. RDY will remain
active and is not placed into a high-impedance state
when OE# is de-asserted.
Configuration Register
The device uses a configuration register to set the
various burst parameters: number of wait states, burst
read mode, active clock edge, RDY configuration, and
synchronous mode active.
memory), the system must drive AVD# and CE# to V ,
IL
and OE# to V when providing an address to the
IH
Reduced Wait-state Handshaking Option
device, and drive WE# and CE# to V , and OE# to V
IL
IH
The device can be equipped with a reduced wait-state
handshaking feature that allows the host system to
simply monitor the RDY signal from the device to deter-
mine when the initial word of burst data is ready to be
read. The host system should use the programmable
wait state configuration to set the number of wait states
for optimal burst mode operation. The initial word of
burst data is indicated by the rising edge of RDY after
OE# goes low.
when writing commands or data. During an asynchro-
nous write operation, the system must drive CE# and
WE# to V and OE# to V when providing an address,
IL
IH
command, and data. Addresses are latched on the last
falling edge of WE# or CE#, while data is latched on the
1st rising edge of WE# or CE#. The asynchronous and
synchronous programing operation is independent of
the Set Device Read Mode bit in the Configuration
Register (see Table 18, “Configuration Register,” on
page 36).
The presence of the reduced wait-state handshaking
feature may be verified by writing the autoselect
command sequence to the device. See “Autoselect
Command Sequence” for details.
The device features an Unlock Bypass mode to facili-
tate faster programming. Once the device enters the
Unlock Bypass mode, only two write cycles are
required to program a word, instead of four.
For optimal burst mode performance on devices
without the reduced wait-state handshaking option, the
host system must set the appropriate number of wait
states in the flash device depending on clock frequency
and the presence of a boundary crossing. See “Set
Configuration Register Command Sequence” section
on page 33 section for more information. The device
will automatically delay RDY and data by one additional
clock cycle when the starting address is odd.
An erase operation can erase one sector, multiple sec-
tors, or the entire device. Table 12, “Am29BDS128H
Sector Address Table,” on page 27 indicates the
address space that each sector occupies. The device
address space is divided into four banks: Banks B and
C contain only 32 Kword sectors, while Banks A and D
contain both 4 Kword boot sectors in addition to 32
Kword sectors. A “bank address” is the address bits
required to uniquely select a bank. Similarly, a “sector
address” is the address bits required to uniquely select
a sector.
The autoselect function allows the host system to
determine whether the flash device is enabled for
reduced wait-state handshaking. See the “Autoselect
Command Sequence” section for more information.
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
13
D A T A S H E E T
I
in the “DC Characteristics” section on page 54
ming algorithm. However, the autoselect codes can
also be accessed in-system through the command
register.
CC2
represents the active current specification for the write
mode. The AC Characteristics section contains timing
specification tables and timing diagrams for write oper-
ations.
When using programming equipment, the autoselect
mode requires V on address pin A9. Address pins
ID
must be as shown in Table 3, “Autoselect Codes (High
Voltage Method),” on page 15. In addition, when verify-
ing sector protection, the sector address must appear
on the appropriate highest order address bits (see
Table 4, “Am29BDS128H Boot Sector/Sector Block
Addresses for Protection/Unprotection,” on page 16).
Table 3 shows the remaining address bits that are
don’t care. When all necessary bits have been set as
required, the programming equipment may then read
the corresponding identifier code on DQ15–DQ0.
However, the autoselect codes can also be accessed
in-system through the command register, for instances
when the device is erased or programmed in a system
without access to high voltage on the A9 pin. The com-
mand sequence is illustrated in Table 20, “Memory
Array Command Definitions,” on page 46. Note that if a
Bank Address (BA) is asserted during the third write
cycle of the autoselect command, the host system can
read autoselect data that bank and then immediately
read array data from the other bank, without exiting the
autoselect mode.
Accelerated Program Operation
The device offers accelerated program operations
through the ACC function. ACC is primarily intended to
allow faster manufacturing throughput at the factory.
If the system asserts V on this input, the device auto-
HH
matically enters the aforementioned Unlock Bypass
mode and uses the higher voltage on the input to
reduce the time required for program operations. The
system would use a two-cycle program command
sequence as required by the Unlock Bypass mode.
Removing V from the ACC input returns the device
HH
to normal operation. Note that sectors must be
unlocked prior to raising ACC to V . Note that the
HH
ACC pin must not be at V for operations other than
HH
accelerated programming, or device damage may
result. In addition, the ACC pin must not be left floating
or unconnected; inconsistent behavior of the device
may result.
When at V , ACC locks all sectors. ACC should be at
IL
V
for all other conditions.
IH
To access the autoselect codes in-system, the host
system can issue the autoselect command via the
command register, as shown in Table 20, “Memory
Array Command Definitions,” on page 46. This method
Autoselect Mode
The autoselect mode provides manufacturer and de-
vice identification, and sector protection verification,
through identifier codes output from the internal regis-
ter (which is separate from the memory array) on
DQ15–DQ0. This mode is primarily intended for pro-
gramming equipment to automatically match a device
to be programmed with its corresponding program-
does not require V . Autoselect mode may only be en-
ID
tered and used when in the asynchronous read mode.
Refer to the “Autoselect Command Sequence” section
on page 36 for more information.
14
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
Table 3. Autoselect Codes (High Voltage Method)
Amax A11
to to
A5
to
DQ15
Description
CE# OE# WE# RESET# A12 A10 A9 A8 A7 A6 A4 A3 A2 A1 A0
to DQ0
Manufacturer ID:
AMD
VID
VID
VID
L
L
L
L
L
L
H
H
H
H
H
H
X
X
X
X
X
X
X
X
L
L
L
L
L
X
L
L
L
L
L
L
L
L
L
H
L
0001h
227Eh
Read Cycle 1
Read Cycle 2
2218h (128 Mb)
221Eh (64 Mb)
H
H
H
X
2200h (128 Mb)
2201h (64 Mb)
Read Cycle 3
H
L
H
L
H
H
H
L
Sector Protection
Verification
0001h (protected),
0000h (unprotected)
SA
DQ15 - DQ8 = 0
DQ7 - Factory Lock Bit
1 = Locked, 0 = Not Locked
DQ6 -Customer Lock Bit
1 = Locked, 0 = Not Locked
DQ5 = Handshake Bit
1 = Reduced wait-state
Handshake, 0 = Standard
Handshake
VID
Indicator Bits
L
L
H
H
H
X
X
X
X
X
X
X
L
X
L
L
L
L
L
H
H
H
L
DQ4 - DQ0 = 0
Hardware Sector
Group Protection
0001h (protected),
0000h (unprotected)
VID
L
L
H
SA
X
Legend: L = Logic Low = V , H = Logic High = V , BA = Bank Address,
IL
IH
SA = Sector Address, X = Don’t care.
Notes:
1. The autoselect codes may also be accessed in-system via command sequences.
2. PPB Protection Status is shown on the data bus
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
15
D A T A S H E E T
Table 4. Am29BDS128H Boot Sector/Sector Block
Sector/
Addresses for Protection/Unprotection
Sector
A22–A12
Sector Block Size
SA131-SA134
SA135-SA138
SA139-SA142
SA143-SA146
SA147-SA150
SA151–SA154
SA155–SA158
SA159–SA162
SA163–SA166
SA167–SA170
SA171–SA174
SA175–SA178
SA179–SA182
SA183–SA186
SA187–SA190
SA191–SA194
SA195–SA198
SA199–SA202
SA203–SA206
SA207–SA210
SA211–SA214
SA215–SA218
SA219–SA222
SA223–SA226
SA227–SA230
SA231–SA234
SA235–SA238
SA239–SA242
SA243–SA246
SA247–SA250
SA251–SA254
SA255–SA258
SA259
011111XXXXX
100000XXXXX
100001XXXXX
100010XXXXX
100011XXXXX
100100XXXXX
100101XXXXX
100110XXXXX
100111XXXXX
101000XXXXX
101001XXXXX
101010XXXXX
101011XXXXX
101100XXXXX
101101XXXXX
101110XXXXX
101111XXXXX
110000XXXXX
110001XXXXX
110010XXXXX
110011XXXXX
110100XXXXX
110101XXXXX
110110XXXXX
110111XXXXX
111000XXXXX
111001XXXXX
111010XXXXX
111011XXXXX
111100XXXXX
111101XXXXX
111110XXXXX
11111100XXX
11111101XXX
11111110XXX
11111111000
11111111001
11111111010
11111111011
11111111100
11111111101
11111111110
11111111111
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
32 Kwords
Sector/
Sector Block Size
Sector
SA0
A22–A12
00000000000
00000000001
00000000010
00000000011
00000000100
00000000101
00000000110
00000000111
00000001XXX
00000010XXX
00000011XXX
000001XXXXX
000010XXXXX
000011XXXXX
000100XXXXX
000101XXXXX
000110XXXXX
000111XXXXX
001000XXXXX
001001XXXXX
001010XXXXX
001011XXXXX
001100XXXXX
001101XXXXX
001110XXXXX
001111XXXXX
010000XXXXX
010001XXXXX
010010XXXXX
010011XXXXX
010100XXXXX
010101XXXXX
010110XXXXX
010111XXXXX
011000XXXXX
011001XXXXX
011010XXXXX
011011XXXXX
011100XXXXX
011101XXXXX
011110XXXXX
4 Kwords
SA1
4 Kwords
SA2
4 Kwords
SA3
4 Kwords
SA4
4 Kwords
SA5
4 Kwords
SA6
4 Kwords
SA7
4 Kwords
SA8
32 Kwords
SA9
32 Kwords
SA10
32 Kwords
SA11–SA14
SA15–SA18
SA19–SA22
SA23-SA26
SA27-SA30
SA31-SA34
SA35-SA38
SA39-SA42
SA43-SA46
SA47-SA50
SA51–SA54
SA55–SA58
SA59–SA62
SA63–SA66
SA67–SA70
SA71–SA74
SA75–SA78
SA79–SA82
SA83–SA86
SA87–SA90
SA91–SA94
SA95–SA98
SA99–SA102
SA103–SA106
SA107–SA110
SA111–SA114
SA115–SA118
SA119–SA122
SA123–SA126
SA127–SA130
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
SA260
32 Kwords
SA261
32 Kwords
SA262
4 Kwords
SA263
4 Kwords
SA264
4 Kwords
SA265
4 Kwords
SA266
4 Kwords
SA267
4 Kwords
SA268
4 Kwords
SA269
4 Kwords
16
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
Table 5. Am29BDS640H Boot Sector/Sector Block
Sector/
Addresses for Protection/Unprotection
Sector
SA135
SA136
SA137
SA138
SA139
SA140
SA141
A21–A12
Sector Block Size
1111111001
1111111010
1111111011
1111111100
1111111101
1111111110
1111111111
4 Kwords
4 Kwords
4 Kwords
4 Kwords
4 Kwords
4 Kwords
4 Kwords
Sector/
Sector
SA0
A21–A12
Sector Block Size
0000000000
0000000001
0000000010
0000000011
0000000100
0000000101
0000000110
0000000111
0000001XXX
0000010XXX
0000011XXX
00001XXXXX
00010XXXXX
00011XXXXX
00100XXXXX
00101XXXXX
00110XXXXX
00111XXXXX
01000XXXXX
01001XXXXX
01010XXXXX
01011XXXXX
01100XXXXX
01101XXXXX
01110XXXXX
01111XXXXX
10000XXXXX
10001XXXXX
10010XXXXX
10011XXXXX
10100XXXXX
10101XXXXX
10110XXXXX
10111XXXXX
11000XXXXX
11001XXXXX
11010XXXXX
11011XXXXX
11100XXXXX
11101XXXXX
11110XXXXX
1111100XXX
1111101XXX
1111110XXX
1111111000
4 Kwords
SA1
4 Kwords
SA2
4 Kwords
SA3
4 Kwords
SA4
4 Kwords
Sector/Sector Block Protection and Un-
protection
SA5
4 Kwords
SA6
4 Kwords
SA7
4 Kwords
The hardware sector protection feature disables both
programming and erase operations in any sector. The
hardware sector unprotection feature re-enables both
program and erase operations in previously protected
sectors. Sector protection/unprotection can be imple-
mented via two methods.
SA8
32 Kwords
SA9
32 Kwords
SA10
32 Kwords
SA11–SA14
SA15–SA18
SA19–SA22
SA23-SA26
SA27-SA30
SA31-SA34
SA35-SA38
SA39-SA42
SA43-SA46
SA47-SA50
SA51–SA54
SA55–SA58
SA59–SA62
SA63–SA66
SA67–SA70
SA71–SA74
SA75–SA78
SA79–SA82
SA83–SA86
SA87–SA90
SA91–SA94
SA95–SA98
SA99–SA102
SA103–SA106
SA107–SA110
SA111–SA114
SA115–SA118
SA119–SA122
SA123–SA126
SA127–SA130
SA131
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
128 (4x32) Kwords
32 Kwords
(Note: For the following discussion, the term “sector”
applies to both sectors and sector blocks. A sector
block consists of two or more adjacent sectors that are
protected or unprotected at the same time (see Table 4,
“Am29BDS128H Boot Sector/Sector Block Addresses
for Protection/Unprotection,” on page 16
Sector Protection
The Am29BDSxxxH family features several levels of
sector protection, which can disable both the program
and erase operations in certain sectors or sector
groups:
Persistent Sector Protection
A command sector protection method that replaces
the old 12 V controlled protection method.
Password Sector Protection
A highly sophisticated protection method that requires
a password before changes to certain sectors or sec-
tor groups are permitted
WP# Hardware Protection
A write protect pin that can prevent program or erase
operations in the outermost sectors.
The WP# Hardware Protection feature is always avail-
able, independent of the software managed protection
method chosen.
Selecting a Sector Protection Mode
All parts default to operate in the Persistent Sector
Protection mode. The customer must then choose if
the Persistent or Password Protection method is most
desirable. There are two one-time programmable
non-volatile bits that define which sector protection
method will be used. If the customer decides to con-
tinue using the Persistent Sector Protection method,
they must set the Persistent Sector Protection Mode
SA132
32 Kwords
SA133
32 Kwords
SA134
4 Kwords
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
17
D A T A S H E E T
Locking Bit. This will permanently set the part to op-
dividual PPBs are programmable. It is the responsibil-
ity of the user to perform the preprogramming
operation. Otherwise, an already erased sector PPBs
has the potential of being over-erased. There is no
hardware mechanism to prevent sector PPBs
over-erasure.
erate only using Persistent Sector Protection. If the
customer decides to use the password method, they
must set the Password Mode Locking Bit. This will
permanently set the part to operate only using pass-
word sector protection.
It is important to remember that setting either the Per-
sistent Sector Protection Mode Locking Bit or the
Password Mode Locking Bit permanently selects the
protection mode. It is not possible to switch between
the two methods once a locking bit has been set. It is
important that one mode is explicitly selected
when the device is first programmed, rather than
relying on the default mode alone. This is so that it
is not possible for a system program or virus to later
set the Password Mode Locking Bit, which would
cause an unexpected shift from the default Persistent
Sector Protection Mode into the Password Protection
Mode.
Persistent Protection Bit Lock (PPB Lock)
A global volatile bit. When set to “1”, the PPBs cannot
be changed. When cleared (“0”), the PPBs are
changeable. There is only one PPB Lock bit per de-
vice. The PPB Lock is cleared after power-up or hard-
ware reset. There is no command sequence to unlock
the PPB Lock.
Dynamic Protection Bit (DYB)
A volatile protection bit is assigned for each sector.
After power-up or hardware reset, the contents of all
DYBs is “0”. Each DYB is individually modifiable
through the DYB Write Command.
The device is shipped with all sectors unprotected.
AMD offers the option of programming and protecting
sectors at the factory prior to shipping the device
through AMD’s ExpressFlash™ Service. Contact an
AMD representative for details.
When the parts are first shipped, the PPBs are
cleared. The DYBs and PPB Lock are defaulted to
power up in the cleared state – meaning the PPBs are
changeable.
When the device is first powered on the DYBs power
up cleared (sectors not protected). The Protection
State for each sector is determined by the logical OR
of the PPB and the DYB related to that sector. For the
sectors that have the PPBs cleared, the DYBs control
whether or not the sector is protected or unprotected.
By issuing the DYB Write command sequences, the
DYBs will be set or cleared, thus placing each sector in
the protected or unprotected state. These are the
so-called Dynamic Locked or Unlocked states. They
are called dynamic states because it is very easy to
switch back and forth between the protected and un-
protected conditions. This allows software to easily
protect sectors against inadvertent changes yet does
not prevent the easy removal of protection when
changes are needed. The DYBs maybe set or cleared
as often as needed.
It is possible to determine whether a sector is pro-
tected or unprotected. See “Autoselect Command Se-
quence” section on page 36 for details.
Persistent Sector Protection
The Persistent Sector Protection method replaces the
old 12 V controlled protection method while at the
same time enhancing flexibility by providing three dif-
ferent sector protection states:
■ Persistently Locked—A sector is protected and
cannot be changed.
■ Dynamically Locked—The sector is protected and
can be changed by a simple command
■ Unlocked—The sector is unprotected and can be
changed by a simple command
In order to achieve these states, three types of “bits”
are going to be used:
The PPBs allow for a more static, and difficult to
change, level of protection. The PPBs retain their state
across power cycles because they are Non-Volatile.
Individual PPBs are set with a command but must all
be cleared as a group through a complex sequence of
program and erasing commands. The PPBs are also
limited to 100 erase cycles.
Persistent Protection Bit (PPB)
A single Persistent (non-volatile) Protection Bit is as-
signed to a maximum four sectors (“Am29BDS128H
Boot Sector/Sector Block Addresses for Protec-
tion/Unprotection” section on page 16). All 4 Kbyte
boot-block sectors have individual sector Persistent
Protection Bits (PPBs) for greater flexibility. Each PPB
is individually modifiable through the PPB Program
Command.
The PBB Lock bit adds an additional level of protec-
tion. Once all PPBs are programmed to the desired
settings, the PPB Lock may be set to “1”. Setting the
PPB Lock disables all program and erase commands
to the Non-Volatile PPBs. In effect, the PPB Lock Bit
locks the PPBs into their current state. The only way to
clear the PPB Lock is to go through a power cycle.
Note: If a PPB requires erasure, all of the sector PPBs
must first be preprogrammed prior to PPB erasing. All
PPBs erase in parallel, unlike programming where in-
18
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
System boot code can determine if any changes to the
In summary, if the PPB is set, and the PPB lock is set,
the sector is protected and the protection can not be
removed until the next power cycle clears the PPB
lock. If the PPB is cleared, the sector can be dynami-
cally locked or unlocked. The DYB then controls
whether or not the sector is protected or unprotected.
PPB are needed e.g. to allow new system code to be
downloaded. If no changes are needed then the boot
code can set the PPB Lock to disable any further
changes to the PPBs during system operation.
The WP# write protect pin adds a final level of hard-
ware protection to the four highest and four lowest 4
Kbyte sectors. When this pin is low it is not possible to
change the contents of these four sectors. These sec-
tors generally hold system boot code. So, the WP# pin
can prevent any changes to the boot code that could
override the choices made while setting up sector pro-
tection during system initialization.
If the user attempts to program or erase a protected
sector, the device ignores the command and returns to
read mode. A program command to a protected sector
enables status polling for approximately t
before
PSP
the device returns to read mode without having modi-
fied the contents of the protected sector. An erase
command to a protected sector enables status polling
for approximately t
to read mode without having erased the protected sec-
tor.
after which the device returns
SEA
It is possible to have sectors that have been persis-
tently locked, and sectors that are left in the dynamic
state. The sectors in the dynamic state are all unpro-
tected. If there is a need to protect some of them, a
simple DYB Write command sequence is all that is
necessary. The DYB write command for the dynamic
sectors switch the DYBs to signify protected and un-
protected, respectively. If there is a need to change the
status of the persistently locked sectors, a few more
steps are required. First, the PPB Lock bit must be dis-
abled by either putting the device through a power-cy-
cle, or hardware reset. The PPBs can then be
changed to reflect the desired settings. Setting the
PPB lock bit once again will lock the PPBs, and the de-
vice operates normally again.
The programming of the DYB, PPB, and PPB lock for a
given sector can be verified by writing a
DYB/PPB/PPB lock verify command to the device.
Persistent Sector Protection Mode
Locking Bit
Like the password mode locking bit, a Persistent Sec-
tor Protection mode locking bit exists to guarantee that
the device remain in software sector protection. Once
set, the Persistent Sector Protection locking bit pre-
vents programming of the password protection mode
locking bit. This guarantees that a hacker could not
place the device in password protection mode.
Note: to achieve the best protection, it’s recommended
to execute the PPB lock bit set command early in the
boot code, and protect the boot code by holding WP#
Password Protection Mode
= V .
IL
The Password Sector Protection Mode method allows
an even higher level of security than the Persistent
Sector Protection Mode. There are two main differ-
ences between the Persistent Sector Protection and
the Password Sector Protection Mode:
Table 6. Sector Protection Schemes
PPB
■ When the device is first powered on, or comes out
of a reset cycle, the PPB Lock bit is set to the
locked state, rather than cleared to the unlocked
state.
DYB
PPB
Lock
Sector State
Unprotected—PPB and DYB are
changeable
0
0
0
■ The only means to clear the PPB Lock bit is by writ-
ing a unique 64-bit Password to the device.
Unprotected—PPB not
changeable, DYB is changeable
0
0
1
The Password Sector Protection method is otherwise
identical to the Persistent Sector Protection method.
0
1
1
0
1
1
1
0
1
1
0
1
0
0
0
1
1
1
Protected—PPB and DYB are
changeable
A 64-bit password is the only additional tool utilized in
this method.
The password is stored in a one-time programmable
(OTP) region of the flash memory. Once the Password
Mode Locking Bit is set, the password is permanently
set with no means to read, program, or erase it. The
password is used to clear the PPB Lock bit. The Pass-
word Unlock command must be written to the flash,
along with a password. The flash device internally
compares the given password with the pre-pro-
Protected—PPB not
changeable, DYB is changeable
Table 6 contains all possible combinations of the DYB,
PPB, and PPB lock relating to the status of the sector.
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
19
D A T A S H E E T
grammed password. If they match, the PPB Lock bit is
Password Verify command from reading the contents
of the password on the pins of the device.
cleared, and the PPBs can be altered. If they do not
match, the flash device does nothing. There is a
built-in 2 µs delay for each “password check.” This
delay is intended to thwart any efforts to run a program
that tries all possible combinations in order to crack
the password.
Persistent Protection Bit Lock
The Persistent Protection Bit (PPB) Lock is a volatile
bit that reflects the state of the Password Mode Lock-
ing Bit after power-up reset. If the Password Mode
Lock Bit is also set, after a hardware reset (RESET#
asserted) or a power-up reset the ONLY means for
clearing the PPB Lock Bit in Password Protection
Mode is to issue the Password Unlock command. Suc-
cessful execution of the Password Unlock command
clears the PPB Lock Bit, allowing for sector PPBs
modifications. Asserting RESET#, taking the device
through a power-on reset, or issuing the PPB Lock Bit
Set command sets the PPB Lock Bit to a “1”.
Password and Password Mode Locking Bit
In order to select the Password sector protection
scheme, the customer must first program the pass-
word. It is recommended that the password be
somehow correlated to the unique Electronic Serial
Number (ESN) of the particular flash device. Each ESN
is different for every flash device; therefore each pass-
word should be different for every flash device. While
programming in the password region, the customer
may perform Password Verify operations.
If the Password Mode Locking Bit is not set, including
Persistent Protection Mode, the PPB Lock Bit is
cleared after power-up or hardware reset. The PPB
Lock Bit can be set by issuing the PPB Lock Bit Set
command. Once set the only means for clearing the
PPB Lock Bit is by issuing a hardware or power-up re-
set. The Password Unlock command is ignored in Per-
sistent Protection Mode.
Once the desired password is programmed in, the
customer must then set the Password Mode Locking
Bit. This operation achieves two objectives:
1. It permanently sets the device to operate using the
Password Protection Mode. It is not possible to re-
verse this function.
2. It also disables all further commands to the pass-
word region. All program, and read operations are
ignored.
High Voltage Sector Protection
Sector protection and unprotection may also be imple-
mented using programming equipment. The procedure
Both of these objectives are important, and if not care-
fully considered, may lead to unrecoverable errors.
The user must be sure that the Password Protection
method is desired when setting the Password Mode
Locking Bit. More importantly, the user must be sure
that the password is correct when the Password Mode
Locking Bit is set. Due to the fact that read operations
are disabled, there is no means to verify what the
password is afterwards. If the password is lost after
setting the Password Mode Locking Bit, there will be
no way to clear the PPB Lock bit.
requires high voltage (V ) to be placed on the
ID
RESET# pin. Refer to Figure 2, “In-System Sector Pro-
tection/ Sector Unprotection Algorithms,” on page 22
for details on this procedure. Note that for sector unpro-
tect, all unprotected sectors must be first protected
prior to the first sector write cycle. Once the Password
Mode Locking bit or Persistent Protection Locking bit
are set, the high voltage sector protect/unprotect capa-
bility is disabled.
Standby Mode
When the system is not reading or writing to the device,
it can place the device in the standby mode. In this
mode, current consumption is greatly reduced, and the
outputs are placed in the high impedance state, inde-
pendent of the OE# input.
The Password Mode Locking Bit, once set, prevents
reading the 64-bit password on the DQ bus and further
password programming. The Password Mode Locking
Bit is not erasable. Once Password Mode Locking Bit
is programmed, the Persistent Sector Protection Lock-
ing Bit is disabled from programming, guaranteeing
that no changes to the protection scheme are allowed.
The device enters the CMOS standby mode when the
CE# and RESET# inputs are both held at V
0.2 V.
CC
The device requires standard access time (t ) for read
access, before it is ready to read data.
CE
64-bit Password
The 64-bit Password is located in its own memory
space and is accessible through the use of the Pass-
word Program and Verify commands (see “Password
Program Command” section on page 40 and “Pass-
word Verify Command” section on page 40). The
password function works in conjunction with the Pass-
word Mode Locking Bit, which when set, prevents the
If the device is deselected during erasure or program-
ming, the device draws active current until the opera-
tion is completed.
I
in the “DC Characteristics” section on page 54
CC3
represents the standby current specification.
20
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
Embedded Algorithms) before the device is ready to
Automatic Sleep Mode
read data again. If RESET# is asserted when a
program or erase operation is not executing, the reset
The automatic sleep mode minimizes Flash device
energy consumption. While in asynchronous mode, the
device automatically enables this mode when
operation is completed within a time of t
(not
READY
during Embedded Algorithms). The system can read
data t after RESET# returns to V .
addresses remain stable for t
+ 60 ns. The auto-
ACC
RH
IH
matic sleep mode is independent of the CE#, WE#, and
OE# control signals. Standard address access timings
provide new data when addresses are changed. While
in sleep mode, output data is latched and always avail-
able to the system. While in synchronous mode, the
device automatically enables this mode when either the
Refer to the “AC Characteristics” section on page 68 for
RESET# parameters and to Figure 33, “Reset Tim-
ings,” on page 68 for the timing diagram.
Output Disable Mode
When the OE# input is at V , output from the device is
first active CLK level is greater than t
or the CLK
IH
ACC
disabled. The outputs are placed in the high imped-
ance state.
runs slower than 5 MHz. Note that a new burst opera-
tion is required to provide new data.
I
in the “DC Characteristics” section on page 54
Figure 1. Temporary Sector Unprotect Operation
CC6
represents the automatic sleep mode current specifica-
tion.
START
RESET#: Hardware Reset Input
The RESET# input provides a hardware method of
resetting the device to reading array data. When
RESET# = VID
(Note 1)
RESET# is driven low for at least a period of t , the
RP
device immediately terminates any operation in
progress, tristates all outputs, resets the configuration
register, and ignores all read/write commands for the
duration of the RESET# pulse. The device also resets
the internal state machine to reading array data. The
operation that was interrupted should be reinitiated
once the device is ready to accept another command
sequence, to ensure data integrity.
Perform Erase or
Program Operations
RESET# = VIH
Temporary Sector
Unprotect Completed
(Note 2)
Current is reduced for the duration of the RESET#
pulse. When RESET# is held at V
0.2 V, the device
). If RESET# is held
SS
draws CMOS standby current (I
CC4
at V but not within V
0.2 V, the standby current will
IL
SS
be greater.
Notes:
RESET# may be tied to the system reset circuitry. A
system reset would thus also reset the Flash memory,
enabling the system to read the boot-up firmware from
the Flash memory.
1. All protected sectors unprotected (If WP# = VIL,
outermost boot sectors will remain protected).
2. All previously protected sectors are protected once
again.
If RESET# is asserted during a program or erase oper-
ation, the device requires a time of t
(during
READY
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
21
D A T A S H E E T
START
START
Protect all sectors:
The indicated portion
of the sector protect
algorithm must be
performed for all
unprotected sectors
prior to issuing the
first sector
PLSCNT = 1
PLSCNT = 1
RESET# = VID
RESET# = VID
Wait 1 ms
Wait 1 ms
unprotect address
No
First Write
Cycle = 60h?
No
First Write
Cycle = 60h?
Temporary Sector
Unprotect Mode
Temporary Sector
Unprotect Mode
Yes
Yes
Set up sector
address
No
All sectors
protected?
Sector Protect:
Write 60h to sector
address with
Yes
Set up first sector
address
A7–A0 =
00000010
Sector Unprotect:
Write 60h to sector
address with
A7:A0 =
Wait 150 µs
Verify Sector
Protect: Write 40h
to sector address
01000010
Reset
PLSCNT = 1
Increment
PLSCNT
with A7–A0 =
00000010
Wait 1.5 ms
Verify Sector
Unprotect: Write
40h to sector
address with
Read from
sector address
with A7–A0 =
00000010
Increment
PLSCNT
A7–A0 =
00000010
No
No
PLSCNT
= 25?
Read from
sector address
Data = 01h?
Yes
with A7–A0 =
00000010
No
Yes
Set up
next sector
address
Yes
No
PLSCNT
= 1000?
Protect another
sector?
Data = 00h?
Yes
Device failed
No
Yes
Remove VID
from RESET#
No
Last sector
verified?
Device failed
Write reset
command
Yes
Remove VID
from RESET#
Sector Unprotect
Algorithm
Sector Protect
Algorithm
Sector Protect
complete
Write reset
command
Sector Unprotect
complete
Figure 2. In-System Sector Protection/
Sector Unprotection Algorithms
22
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
can be programmed and locked only once. Note that
SecSi™ (Secured Silicon) Sector
Flash Memory Region
the accelerated programming (ACC) and unlock by-
pass functions are not available when programming
the SecSi Sector.
The SecSi (Secured Silicon) Sector feature provides a
Flash memory region that enables permanent part
identification through an Electronic Serial Number
(ESN) The 128-word SecSi sector is divided into 64
factory-lockable words that can be programmed and
locked by the customer. The SecSi sector is located at
addresses 000000h-00007Fh in both Persistent Pro-
tection mode and Password Protection mode. It uses
indicator bits (DQ6, DQ7) to indicate the fac-
tory-locked and customer-locked status of the part.
The Customer-lockable SecSi Sector area can be pro-
tected using one of the following procedures:
■ Write the three-cycle Enter SecSi Sector Region
command sequence, and then follow the in-system
sector protect algorithm as shown in Figure 2, ex-
cept that RESET# may be at either V or V . This
IH
ID
allows in-system protection of the SecSi Sector Re-
gion without raising any device pin to a high voltage.
Note that this method is only applicable to the SecSi
Sector.
The system accesses the SecSi Sector through a
command sequence (see “Enter SecSi™ Sector/Exit
SecSi Sector Command Sequence”). After the system
has written the Enter SecSi Sector command se-
quence, it may read the SecSi Sector by using the ad-
dresses normally occupied by the boot sectors. This
mode of operation continues until the system issues
the Exit SecSi Sector command sequence, or until
power is removed from the device. On power-up, or
following a hardware reset, the device reverts to send-
ing commands to the normal address space.
■ Write the three-cycle Enter SecSi Sector Secure
Region command sequence, and then use the alter-
nate method of sector protection described in the
High Voltage Sector Protection section.
Once the SecSi Sector is locked and verified, the sys-
tem must write the Exit SecSi Sector Region com-
mand sequence to return to reading and writing the
remainder of the array.
The SecSi Sector lock must be used with caution
since, once locked, there is no procedure available for
unlocking the SecSi Sector area and none of the bits
in the SecSi Sector memory space can be modified in
any way.
Factory-Locked Area (64 words)
The factory-locked area of the SecSi Sector
(000000h-00003Fh) is locked when the part is
shipped, whether or not the area was programmed at
the factory. The SecSi Sector Factory-locked Indicator
Bit (DQ7) is permanently set to a “1”. AMD offers the
ExpressFlash service to program the factory-locked
area with a random ESN, a customer-defined code, or
any combination of the two. Because only AMD can
program and protect the factory-locked area, this
method ensures the security of the ESN once the
product is shipped to the field. Contact an AMD repre-
sentative for details on using the AMD ExpressFlash
service.
SecSi Sector Protection Bits
The SecSi Sector Protection Bits prevent program-
ming of the SecSi Sector memory area. Once set, the
SecSi Sector memory area contents are non-modifi-
able.
Hardware Data Protection
The command sequence requirement of unlock cycles
for programming or erasing provides data protection
against inadvertent writes (refer to Table 20, “Memory
Array Command Definitions,” on page 46 for command
definitions).
TM
Table 7. SecSi Sector Addresses
Sector Size
Address Range
The device offers two types of data protection at the
sector level:
Am29BDS128H/
Am29BDS640H
128 words
000000h–00007Fh
■ The PPB and DYB associated command se-
quences disables or re-enables both program and
erase operations in any sector or sector group.
Factory-Locked Area
64 words
64 words
000000h–00003Fh
000040h–00007Fh
Customer-Lockable Area
Customer-Lockable Area (64 words)
■ When WP# is at V , the four outermost sectors are
IL
locked.
The customer-lockable area of the SecSi Sector
(000040h-00007Fh) is shipped unprotected, which al-
lows the customer to program and optionally lock the
area as appropriate for the application. The SecSi
Sector Customer-locked Indicator Bit (DQ6) is shipped
as “0” and can be permanently locked to “1” by issuing
the SecSi Protection Bit Program Command. The
SecSi Sector can be read any number of times, but
■ When ACC is at V , all sectors are locked.
IL
The following hardware data protection measures
prevent accidental erasure or programming, which
might otherwise be caused by spurious system level
signals during V
tions, or from system noise.
power-up and power-down transi-
CC
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
23
D A T A S H E E T
CE# and WE# must be a logical zero while OE# is a
Write Protect (WP#)
logical one.
The Write Protect feature provides a hardware method
of protecting the four outermost sectors. This function
is provided by the WP# pin and overrides the previ-
ously discussed Sector Protection/Unprotection
method.
Power-Up Write Inhibit
If WE# = CE# = RESET# = V and OE# = V during
IL
IH
power up, the device does not accept commands on
the rising edge of WE#. The internal state machine is
automatically reset to the read mode on power-up.
If the system asserts V on the WP# pin, the device
IL
disables program and erase functions in the eight “out-
ermost” 4 Kword boot sectors.
COMMON FLASH MEMORY INTERFACE
(CFI)
If the system asserts V on the WP# pin, the device
IH
The Common Flash Interface (CFI) specification out-
lines device and host system software interrogation
handshake, which allows specific vendor-specified
software algorithms to be used for entire families of
devices. Software support can then be device-indepen-
dent, JEDEC ID-independent, and forward- and back-
ward-compatible for the specified flash device families.
Flash vendors can standardize their existing interfaces
for long-term compatibility.
reverts to whether the boot sectors were last set to be
protected or unprotected. That is, sector protection or
unprotection for these sectors depends on whether
they were last protected or unprotected using the
method described in “PPB Program Command” sec-
tion on page 43.
Note that the WP# pin must not be left floating or un-
connected; inconsistent behavior of the device may re-
sult.
This device enters the CFI Query mode when the
system writes the CFI Query command, 98h, to
address 55h any time the device is ready to read array
data. The system can read CFI information at the
addresses given in Tables 8-11. To terminate reading
CFI data, the system must write the reset command.
Low V Write Inhibit
CC
When V
is less than V
, the device does not
LKO
CC
accept any write cycles. This protects data during V
CC
power-up and power-down. The command register and
all internal program/erase circuits are disabled, and the
device resets to reading array data. Subsequent writes
The system can also write the CFI query command
when the device is in the autoselect mode. The device
enters the CFI query mode, and the system can read
CFI data at the addresses given in Tables 8-11. The
system must write the reset command to return the
device to the autoselect mode.
are ignored until V is greater than V
. The system
CC
LKO
must provide the proper signals to the control inputs to
prevent unintentional writes when V is greater than
CC
V
.
LKO
Write Pulse “Glitch” Protection
For further information, please refer to the CFI Specifi-
cation and CFI Publication 100, available via the AMD
site at the following URL:
Noise pulses of less than 5 ns (typical) on OE#, CE# or
WE# do not initiate a write cycle.
Logical Inhibit
http://www.amd.com/flash/cfi.
Write cycles are inhibited by holding any one of OE# =
Alternatively, contact an AMD representative for copies
V , CE# = V or WE# = V . To initiate a write cycle,
IL
IH
IH
Table 8. CFI Query Identification String
Description
Addresses
Data
10h
11h
12h
0051h
0052h
0059h
Query Unique ASCII string “QRY”
Primary OEM Command Set
13h
14h
0002h
0000h
15h
16h
0040h
0000h
Address for Primary Extended Table
17h
18h
0000h
0000h
Alternate OEM Command Set (00h = none exists)
Address for Alternate OEM Extended Table (00h = none exists)
19h
1Ah
0000h
0000h
24
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
Table 9. System Interface String
Addresses
Data
Description
VCC Min. (write/erase)
D7–D4: volt, D3–D0: 100 millivolt
1Bh
0017h
VCC Max. (write/erase)
D7–D4: volt, D3–D0: 100 millivolt
1Ch
0019h
1Dh
1Eh
1Fh
20h
21h
22h
23h
24h
25h
26h
0000h
0000h
0004h
0000h
0009h
0000h
0004h
0000h
0004h
0000h
VPP Min. voltage (00h = no VPP pin present)
V
PP Max. voltage (00h = no VPP pin present)
Typical timeout per single byte/word write 2N µs
Typical timeout for Min. size buffer write 2N µs (00h = not supported)
Typical timeout per individual block erase 2N ms
Typical timeout for full chip erase 2N ms (00h = not supported)
Max. timeout for byte/word write 2N times typical
Max. timeout for buffer write 2N times typical
Max. timeout per individual block erase 2N times typical
Max. timeout for full chip erase 2N times typical (00h = not supported)
Table 10. Device Geometry Definition
Description
Addresses
Data
Device Size = 2N byte
BDS128H = 0018h; BDS640H = 0017h
27h
001xh
28h
29h
0001h
0000h
Flash Device Interface description (refer to CFI publication 100)
2Ah
2Bh
0000h
0000h
Max. number of bytes in multi-byte write = 2N
(00h = not supported)
2Ch
0003h
Number of Erase Block Regions within device
2Dh
2Eh
2Fh
30h
0007h
0000h
0020h
0000h
Erase Block Region 1 Information
(refer to the CFI specification or CFI publication 100)
31h
32h
33h
34h
00xDh
0000h
0000h
0001h
Erase Block Region 2 Information
Address 31h: BDS128H = 00FDh; BDS640H = 007Dh
35h
36h
37h
38h
0007h
0000h
0020h
0000h
Erase Block Region 3 Information
Erase Block Region 4 Information
39h
3Ah
3Bh
3Ch
0000h
0000h
0000h
0000h
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
25
D A T A S H E E T
Table 11. Primary Vendor-Specific Extended Query
Addresses
Data
Description
40h
41h
42h
0050h
0052h
0049h
Query-unique ASCII string “PRI”
43h
44h
0031h
0033h
Major version number, ASCII
Minor version number, ASCII
Address Sensitive Unlock (Bits 1-0)
0 = Required, 1 = Not Required
45h
000Ch
Silicon Technology (Bits 5-2) 0011 = 0.13 µm
Erase Suspend
0 = Not Supported, 1 = To Read Only, 2 = To Read & Write
46h
47h
48h
49h
4Ah
4Bh
4Ch
0002h
0001h
0000h
0007h
00x7h
0001h
0000h
Sector Protect
0 = Not Supported, X = Number of sectors in per group
Sector Temporary Unprotect
00 = Not Supported, 01 = Supported
Sector Protect/Unprotect scheme
07 = Advanced Sector Protection
Simultaneous Operation: number of Sectors in all banks except boot block
BDS128H = 00E7h; BDS640H = 0077h
Burst Mode Type
00 = Not Supported, 01 = Supported
Page Mode Type
00 = Not Supported, 01 = 4 Word Page, 02 = 8 Word Page, 04 = 16 Word Page
ACC (Acceleration) Supply Minimum
4Dh
4Eh
00B5h
00C5h
00h = Not Supported, D7-D4: Volt, D3-D0: 100 mV
ACC (Acceleration) Supply Maximum
00h = Not Supported, D7-D4: Volt, D3-D0: 100 mV
4Fh
50h
57h
0001h
0000h
0004h
Boot Sector Flag
Program Suspend. 00h = not supported
Bank Organization: X = Number of banks
58h
59h
5Ah
5Bh
0027h / 0017h
0060h / 0030h
0060h / 0030h
0027h / 0017h
Bank A – Bank D Region Information. X = Number of sectors in bank.
Address: 58h = Bank A; 59h = Bank B; 5Ah = Bank C; 5Bh = Bank D
Data: BDS128H / BDS640H
26
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
Table 12. Am29BDS128H Sector Address Table
Bank Sector
SA0
Sector Size
4 Kwords
(x16) Address Range
000000h–000FFFh
001000h–001FFFh
002000h–002FFFh
003000h–003FFFh
004000h–004FFFh
005000h–005FFFh
006000h–006FFFh
007000h–007FFFh
008000h–00FFFFh
010000h–017FFFh
018000h–01FFFFh
020000h–027FFFh
028000h–02FFFFh
030000h–037FFFh
038000h–03FFFFh
040000h–047FFFh
048000h–04FFFFh
050000h–057FFFh
058000h–05FFFFh
060000h–067FFFh
068000h–06FFFFh
070000h–077FFFh
078000h–07FFFFh
080000h–087FFFh
088000h–08FFFFh
090000h–097FFFh
098000h–09FFFFh
0A0000h–0A7FFFh
0A8000h–0AFFFFh
0B0000h–0B7FFFh
0B8000h–0BFFFFh
0C0000h–0C7FFFh
0C8000h–0CFFFFh
0D0000h–0D7FFFh
0D8000h–0DFFFFh
0E0000h–0E7FFFh
0E8000h–0EFFFFh
0F0000h–0F7FFFh
0F8000h–0FFFFFh
Bank Sector
SA39
SA40
SA41
SA42
SA43
SA44
SA45
SA46
SA47
SA48
SA49
SA50
SA51
SA52
SA53
SA54
SA55
SA56
SA57
SA58
SA59
SA60
SA61
SA62
SA63
SA64
SA65
SA66
SA67
SA68
SA69
SA70
Sector Size
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
(x16) Address Range
100000h–107FFFh
108000h–10FFFFh
110000h–117FFFh
118000h–11FFFFh
120000h–127FFFh
128000h–12FFFFh
130000h–137FFFh
138000h–13FFFFh
140000h–147FFFh
148000h–14FFFFh
150000h–157FFFh
158000h–15FFFFh
160000h–167FFFh
168000h–16FFFFh
170000h–177FFFh
178000h–17FFFFh
180000h–187FFFh
188000h–18FFFFh
190000h–197FFFh
198000h–19FFFFh
1A0000h–1A7FFFh
1A8000h–1AFFFFh
1B0000h–1B7FFFh
1B8000h–1BFFFFh
1C0000h–1C7FFFh
1C8000h–1CFFFFh
1D0000h–1D7FFFh
1D8000h–1DFFFFh
1E0000h–1E7FFFh
1E8000h–1EFFFFh
1F0000h–1F7FFFh
1F8000h–1FFFFFh
SA1
4 Kwords
SA2
4 Kwords
SA3
4 Kwords
SA4
4 Kwords
SA5
4 Kwords
SA6
4 Kwords
SA7
4 Kwords
SA8
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
SA9
SA10
SA11
SA12
SA13
SA14
SA15
SA16
SA17
SA18
SA19
SA20
SA21
SA22
SA23
SA24
SA25
SA26
SA27
SA28
SA29
SA30
SA31
SA32
SA33
SA34
SA35
SA36
SA37
SA38
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
27
D A T A S H E E T
Table 12. Am29BDS128H Sector Address Table (Continued)
Bank Sector
SA71
SA72
SA73
SA74
SA75
SA76
SA77
SA78
SA79
SA80
SA81
SA82
SA83
SA84
SA85
SA86
SA87
SA88
SA89
SA90
SA91
SA92
SA93
SA94
SA95
SA96
SA97
SA98
SA99
SA100
SA101
SA102
Sector Size
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
(x16) Address Range
200000h–207FFFh
208000h–20FFFFh
210000h–217FFFh
218000h–21FFFFh
220000h–227FFFh
228000h–22FFFFh
230000h–237FFFh
238000h–23FFFFh
240000h–247FFFh
248000h–24FFFFh
250000h–257FFFh
258000h–25FFFFh
260000h–267FFFh
268000h–26FFFFh
270000h–277FFFh
278000h–27FFFFh
280000h–287FFFh
288000h–28FFFFh
290000h–297FFFh
298000h–29FFFFh
2A0000h–2A7FFFh
2A8000h–2AFFFFh
2B0000h–2B7FFFh
2B8000h–2BFFFFh
2C0000h–2C7FFFh
2C8000h–2CFFFFh
2D0000h–2D7FFFh
2D8000h–2DFFFFh
2E0000h–2E7FFFh
2E8000h–2EFFFFh
2F0000h–2F7FFFh
2F8000h–2FFFFFh
Bank Sector
SA103
SA104
SA105
SA106
SA107
SA108
SA109
SA110
SA111
SA112
SA113
SA114
SA115
SA116
SA117
SA118
SA119
SA120
SA121
SA122
SA123
SA124
SA125
SA126
SA127
SA128
SA129
SA130
SA131
SA132
SA133
SA134
Sector Size
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
(x16) Address Range
300000h–307FFFh
308000h–30FFFFh
310000h–317FFFh
318000h–31FFFFh
320000h–327FFFh
328000h–32FFFFh
330000h–337FFFh
338000h–33FFFFh
340000h–347FFFh
348000h–34FFFFh
350000h–357FFFh
358000h–35FFFFh
360000h–367FFFh
368000h–36FFFFh
370000h–377FFFh
378000h–37FFFFh
380000h–387FFFh
388000h–38FFFFh
390000h–397FFFh
398000h–39FFFFh
3A0000h–3A7FFFh
3A8000h–3AFFFFh
3B0000h–3B7FFFh
3B8000h–3BFFFFh
3C0000h–3C7FFFh
3C8000h–3CFFFFh
3D0000h–3D7FFFh
3D8000h–3DFFFFh
3E0000h–3E7FFFh
3E8000h–3EFFFFh
3F0000h–3F7FFFh
3F8000h–3FFFFFh
28
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
Table 12. Am29BDS128H Sector Address Table (Continued)
Bank Sector
SA135
SA136
SA137
SA138
SA139
SA140
SA141
SA142
SA143
SA144
SA145
SA146
SA147
SA148
SA149
SA150
SA151
SA152
SA153
SA154
SA155
SA156
SA157
SA158
SA159
SA160
SA161
SA162
SA163
SA164
SA165
SA166
Sector Size
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
(x16) Address Range
400000h–407FFFh
408000h–40FFFFh
410000h–417FFFh
418000h–41FFFFh
420000h–427FFFh
428000h–42FFFFh
430000h–437FFFh
438000h–43FFFFh
440000h–447FFFh
448000h–44FFFFh
450000h–457FFFh
458000h–45FFFFh
460000h–467FFFh
468000h–46FFFFh
470000h–477FFFh
478000h–47FFFFh
480000h–487FFFh
488000h–48FFFFh
490000h–497FFFh
498000h–49FFFFh
4A0000h–4A7FFFh
4A8000h–4AFFFFh
4B0000h–4B7FFFh
4B8000h–4BFFFFh
4C0000h–4C7FFFh
4C8000h–4CFFFFh
4D0000h–4D7FFFh
4D8000h–4DFFFFh
4E0000h–4E7FFFh
4E8000h–4EFFFFh
4F0000h–4F7FFFh
4F8000h–4FFFFFh
Bank Sector
SA167
SA168
SA169
SA170
SA171
SA172
SA173
SA174
SA175
SA176
SA177
SA178
SA179
SA180
SA181
SA182
SA183
SA184
SA185
SA186
SA187
SA188
SA189
SA190
SA191
SA192
SA193
SA194
SA195
SA196
SA197
SA198
Sector Size
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
(x16) Address Range
500000h–507FFFh
508000h–50FFFFh
510000h–517FFFh
518000h–51FFFFh
520000h–527FFFh
528000h–52FFFFh
530000h–537FFFh
538000h–53FFFFh
540000h–547FFFh
548000h–54FFFFh
550000h–557FFFh
558000h–55FFFFh
560000h–567FFFh
568000h–56FFFFh
570000h–577FFFh
578000h–57FFFFh
580000h–587FFFh
588000h–58FFFFh
590000h–597FFFh
598000h–59FFFFh
5A0000h–5A7FFFh
5A8000h–5AFFFFh
5B0000h–5B7FFFh
5B8000h–5BFFFFh
5C0000h–5C7FFFh
5C8000h–5CFFFFh
5D0000h–5D7FFFh
5D8000h–5DFFFFh
5E0000h–5E7FFFh
5E8000h–5EFFFFh
5F0000h–5F7FFFh
5F8000h–5FFFFFh
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
29
D A T A S H E E T
Table 12. Am29BDS128H Sector Address Table (Continued)
Bank Sector
SA199
SA200
SA201
SA202
SA203
SA204
SA205
SA206
SA207
SA208
SA209
SA210
SA211
SA212
SA213
SA214
SA215
SA216
SA217
SA218
SA219
SA220
SA221
SA222
SA223
SA224
SA225
SA226
SA227
SA228
SA229
SA230
Sector Size
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
(x16) Address Range
600000h–607FFFh
608000h–60FFFFh
610000h–617FFFh
618000h–61FFFFh
620000h–627FFFh
628000h–62FFFFh
630000h–637FFFh
638000h–63FFFFh
640000h–647FFFh
648000h–64FFFFh
650000h–657FFFh
658000h–65FFFFh
660000h–667FFFh
668000h–66FFFFh
670000h–677FFFh
678000h–67FFFFh
680000h–687FFFh
688000h–68FFFFh
690000h–697FFFh
698000h–69FFFFh
6A0000h–6A7FFFh
6A8000h–6AFFFFh
6B0000h–6B7FFFh
6B8000h–6BFFFFh
6C0000h–6C7FFFh
6C8000h–6CFFFFh
6D0000h–6D7FFFh
6D8000h–6DFFFFh
6E0000h–6E7FFFh
6E8000h–6EFFFFh
6F0000h–6F7FFFh
6F8000h–6FFFFFh
Bank Sector
SA231
SA232
SA233
SA234
SA235
SA236
SA237
SA238
SA239
SA240
SA241
SA242
SA243
SA244
SA245
SA246
SA247
SA248
SA249
SA250
SA251
SA252
SA253
SA254
SA255
SA256
SA257
SA258
SA259
SA260
SA261
SA262
SA263
SA264
SA265
SA266
SA267
SA268
SA269
Sector Size
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
4 Kwords
(x16) Address Range
700000h–707FFFh
708000h–70FFFFh
710000h–717FFFh
718000h–71FFFFh
720000h–727FFFh
728000h–72FFFFh
730000h–737FFFh
738000h–73FFFFh
740000h–747FFFh
748000h–74FFFFh
750000h–757FFFh
758000h–75FFFFh
760000h–767FFFh
768000h–76FFFFh
770000h–777FFFh
778000h–77FFFFh
780000h–787FFFh
788000h–78FFFFh
790000h–797FFFh
798000h–79FFFFh
7A0000h–7A7FFFh
7A8000h–7AFFFFh
7B0000h–7B7FFFh
7B8000h–7BFFFFh
7C0000h–7C7FFFh
7C8000h–7CFFFFh
7D0000h–7D7FFFh
7D8000h–7DFFFFh
7E0000h–7E7FFFh
7E8000h–7EFFFFh
7F0000h–7F7FFFh
7F8000h–7F8FFFh
7F9000h–7F9FFFh
7FA000h–7FAFFFh
7FB000h–7FBFFFh
7FC000h–7FCFFFh
7FD000h–7FDFFFh
7FE000h–7FEFFFh
7FF000h–7FFFFFh
4 Kwords
4 Kwords
4 Kwords
4 Kwords
4 Kwords
4 Kwords
4 Kwords
30
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
Table 13. Am29BDS640H Sector Address Table
Bank
Sector Sector Size
Address Range
000000h–000FFFh
001000h–001FFFh
002000h–002FFFh
003000h–003FFFh
004000h–004FFFh
005000h–005FFFh
006000h–006FFFh
007000h–007FFFh
008000h–00FFFFh
010000h–017FFFh
018000h–01FFFFh
020000h–027FFFh
028000h–02FFFFh
030000h–037FFFh
038000h–03FFFFh
040000h–047FFFh
048000h–04FFFFh
050000h–057FFFh
058000h–05FFFFh
060000h–067FFFh
068000h–06FFFFh
070000h–077FFFh
078000h–07FFFFh
080000h–087FFFh
088000h–08FFFFh
090000h–097FFFh
098000h–09FFFFh
0A0000h–0A7FFFh
0A8000h–0AFFFFh
0B0000h–0B7FFFh
0B8000h–0BFFFFh
0C0000h–0C7FFFh
0C8000h–0CFFFFh
0D0000h–0D7FFFh
0D8000h–0DFFFFh
0E0000h–0E7FFFh
Bank
Sector
SA36
SA37
SA38
SA39
SA40
SA41
SA42
SA43
SA44
SA45
SA46
SA47
SA48
SA49
SA50
SA51
SA52
SA53
SA54
SA55
SA56
SA57
SA58
SA59
SA60
SA61
SA62
SA63
SA64
SA65
SA66
SA67
SA68
SA69
SA70
Sector Size
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
Address Range
0E8000h–0EFFFFh
0F0000h–0F7FFFh
0F8000h–0FFFFFh
100000h–107FFFh
108000h–10FFFFh
110000h–117FFFh
118000h–11FFFFh
120000h–127FFFh
128000h–12FFFFh
130000h–137FFFh
138000h–13FFFFh
140000h–147FFFh
148000h–14FFFFh
150000h–157FFFh
158000h–15FFFFh
160000h–167FFFh
168000h–16FFFFh
170000h–177FFFh
178000h–17FFFFh
180000h–187FFFh
188000h–18FFFFh
190000h–197FFFh
198000h–19FFFFh
1A0000h–1A7FFFh
1A8000h–1AFFFFh
1B0000h–1B7FFFh
1B8000h–1BFFFFh
1C0000h–1C7FFFh
1C8000h–1CFFFFh
1D0000h–1D7FFFh
1D8000h–1DFFFFh
1E0000h–1E7FFFh
1E8000h–1EFFFFh
1F0000h–1F7FFFh
1F8000h–1FFFFFh
SA0
SA1
4 Kwords
4 Kwords
SA2
4 Kwords
SA3
4 Kwords
SA4
4 Kwords
SA5
4 Kwords
SA6
4 Kwords
SA7
4 Kwords
SA8
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
SA9
SA10
SA11
SA12
SA13
SA14
SA15
SA16
SA17
SA18
SA19
SA20
SA21
SA22
SA23
SA24
SA25
SA26
SA27
SA28
SA29
SA30
SA31
SA32
SA33
SA34
SA35
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
31
D A T A S H E E T
Table 13. Am29BDS640H Sector Address Table
Bank
Sector Sector Size
Address Range
200000h–207FFFh
208000h–20FFFFh
210000h–217FFFh
218000h–21FFFFh
220000h–227FFFh
228000h–22FFFFh
230000h–237FFFh
238000h–23FFFFh
240000h–247FFFh
248000h–24FFFFh
250000h–257FFFh
258000h–25FFFFh
260000h–267FFFh
268000h–26FFFFh
270000h–277FFFh
278000h–27FFFFh
280000h–287FFFh
288000h–28FFFFh
290000h–297FFFh
298000h–29FFFFh
2A0000h–2A7FFFh
2A8000h–2AFFFFh
2B0000h–2B7FFFh
2B8000h–2BFFFFh
2C0000h–2C7FFFh
2C8000h–2CFFFFh
2D0000h–2D7FFFh
2D8000h–2DFFFFh
2E0000h–2E7FFFh
2E8000h–2EFFFFh
2F0000h–2F7FFFh
2F8000h–2FFFFFh
300000h–307FFFh
308000h–30FFFFh
310000h–317FFFh
318000h–31FFFFh
Bank
Sector
SA107
SA108
SA109
SA110
SA111
SA112
SA113
SA114
SA115
SA116
SA117
SA118
SA119
SA120
SA121
SA122
SA123
SA124
SA125
SA126
SA127
SA128
SA129
SA130
SA131
SA132
SA133
SA134
SA135
SA136
SA137
SA138
SA139
SA140
SA141
Sector Size
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
4 Kwords
Address Range
320000h–327FFFh
328000h–32FFFFh
330000h–337FFFh
338000h–33FFFFh
340000h–347FFFh
348000h–34FFFFh
350000h–357FFFh
358000h–35FFFFh
360000h–367FFFh
368000h–36FFFFh
370000h–377FFFh
378000h–37FFFFh
380000h–387FFFh
388000h–38FFFFh
390000h–397FFFh
398000h–39FFFFh
3A0000h–3A7FFFh
3A8000h–3AFFFFh
3B0000h–3B7FFFh
3B8000h–3BFFFFh
3C0000h–3C7FFFh
3C8000h–3CFFFFh
3D0000h–3D7FFFh
3D8000h–3DFFFFh
3E0000h–3E7FFFh
3E8000h–3EFFFFh
3F0000h–3F7FFFh
3F8000h–3F8FFFh
3F9000h–3F9FFFh
3FA000h–3FAFFFh
3FB000h–3FBFFFh
3FC000h–3FCFFFh
3FD000h–3FDFFFh
3FE000h–3FEFFFh
3FF000h–3FFFFFh
SA71
SA72
SA73
SA74
SA75
SA76
SA77
SA78
SA79
SA80
SA81
SA82
SA83
SA84
SA85
SA86
SA87
SA88
SA89
SA90
SA91
SA92
SA93
SA94
SA95
SA96
SA97
SA98
SA99
SA100
SA101
SA102
SA103
SA104
SA105
SA106
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
32 Kwords
4 Kwords
4 Kwords
4 Kwords
4 Kwords
4 Kwords
4 Kwords
4 Kwords
32
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
COMMAND DEFINITIONS
Writing specific address and data commands or
sequences into the command register initiates device
operations. Table 20, “Memory Array Command Defini-
tions,” on page 46 defines the valid register command
sequences. Writing incorrect address and data values
or writing them in the improper sequence may place the
device in an unknown state. The system must write the
reset command to return the device to reading array
data. Refer to the AC Characteristics section for timing
diagrams.
be C0h, address bits A11–A0 should be 555h, and
address bits A19–A12 set the code to be latched. The
device will power up or after a hardware reset with the
default setting, which is in asynchronous mode. The
register must be set before the device can enter syn-
chronous mode. The configuration register can not be
changed during device operations (program, erase, or
sector lock).
Reading Array Data
Power-up/
The device is automatically set to reading array data
after device power-up. No commands are required to
retrieve data in asynchronous mode. Each bank is
ready to read array data after completing an Embedded
Program or Embedded Erase algorithm.
Hardware Reset
Asynchronous Read
Mode Only
After the device accepts an Erase Suspend command,
the corresponding bank enters the erase-sus-
pend-read mode, after which the system can read data
from any non-erase-suspended sector within the same
bank. After completing a programming operation in the
Erase Suspend mode, the system may once again
read array data from any non-erase-suspended sector
within the same bank. See the “Erase Suspend/Erase
Resume Commands” section on page 39 for more
information.
Set Burst Mode
Configuration Register
Command for
Synchronous Mode
(D15 = 0)
Set Burst Mode
Configuration Register
Command for
Asynchronous Mode
(D15 = 1)
Synchronous Read
The system must issue the reset command to return a
bank to the read (or erase-suspend-read) mode if DQ5
goes high during an active program or erase operation,
or if the bank is in the autoselect mode. See the “Reset
Command” section on page 36 for more information.
Mode Only
Figure 3. Synchronous/Asynchronous State
Diagram
See also “Requirements for Asynchronous Read Oper-
ation (Non-Burst)” section on page 11 and “Require-
ments for Synchronous (Burst) Read Operation”
section on page 11 for more information. The Asyn-
chronous Read and Synchronous/Burst Read tables
provide the read parameters, and Figure 16, “CLK Syn-
chronous Burst Mode Read (rising active CLK),” on
page 58, Figure 18, “Synchronous Burst Mode Read,”
on page 59, and Figure 31, “Asynchronous Mode Read
with Latched Addresses,” on page 67 show the timings.
Read Mode Setting
On power-up or hardware reset, the device is set to be
in asynchronous read mode. This setting allows the
system to enable or disable burst mode during system
operations. Address A19 determines this setting: “1” for
asynchronous mode, “0” for synchronous mode.
Programmable Wait State Configuration
The programmable wait state feature informs the
device of the number of clock cycles that must elapse
after AVD# is driven active before data will be available.
This value is determined by the input frequency of the
device. Address bits A14–A12 determine the setting
(see Table 14, “Programmable Wait State Settings,” on
page 34).
Set Configuration Register Command Se-
quence
The device uses a configuration register to set the
various burst parameters: number of wait states, burst
read mode, active clock edge, RDY configuration, and
synchronous mode active. The configuration register
must be set before the device will enter burst mode.
The wait state command sequence instructs the device
to set a particular number of clock cycles for the initial
access in burst mode. The number of wait states that
should be programmed into the device is directly
related to the clock frequency.
The configuration register is loaded with a three-cycle
command sequence. The first two cycles are standard
unlock sequences. On the third cycle, the data should
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
33
D A T A S H E E T
Table 14. Programmable Wait State Settings
Total Initial Access
address bits A14–A12 to 010 for the system/device to
execute at maximum speed.
Table 15 describes the typical number of clock cycles
(wait states) for various conditions.
A14
A13
A12
Cycles
0
0
0
2
Table 15. Wait States for Reduced Wait-state
Handshaking
0
0
1
3
0
1
0
4
System
Frequency
Range
Device
Speed
Rating
0
1
1
5
Even Initial
Address
Odd Initial
Address
1
0
0
6
6–22 MHz
22–28 MHz
28–43 MHz
43–54 MHz
6–28 MHz
28–35 MHz
35–53 MHz
53–66 MHz
2
2
3
4
2
2
3
4
2
3
4
5
2
3
4
5
1
0
1
7 (default)
Reserved
Reserved
D
1
1
0
(54 MHz)
1
1
1
Notes:
1. Upon power-up or hardware reset, the default setting is
seven wait states.
E
2. RDY will default to being active with data when the Wait
State Setting is set to a total initial access cycle of 2.
(66 MHz)
It is recommended that the wait state command
sequence be written, even if the default wait state value
is desired, to ensure the device is set as expected. A
hardware reset will set the wait state to the default set-
ting.
Notes:
1. If the latched address is 3Eh or 3Fh (or an address offset
from either address by a multiple of 64), add two access
cycles to the values listed.
2. In the 8-, 16-, and 32-word burst modes, the address
pointer does not cross 64-word boundaries (3Fh, or
addresses offset from 3Fh by a multiple of 64).
Reduced Wait-state Handshaking Option
If the device is equipped with the reduced wait-state
handshaking option, the host system should set
3. Typical initial access cycles may vary depending on
system margin requirements.
34
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
the starting location. The sixteen- and thirty-two linear
Standard Handshaking Option
wrap around modes operate in a fashion similar to the
eight-word mode.
For optimal burst mode performance on devices with
the standard handshaking option, the host system
must set the appropriate number of wait states in the
flash device depending on the clock frequency.
Table 17 shows the address bits and settings for the
four read modes.
Table 16 describes the typical number of clock cycles
(wait states) for various conditions with A14-A12 set to
101.
Table 17. Read Mode Settings
Address Bits
Burst Modes
A16
0
A15
0
Table 16. Wait States for Standard Handshaking
Continuous
Typical No. of Clock
Conditions at Address
Cycles after AVD# Low
8-word linear wrap around
16-word linear wrap around
32-word linear wrap around
0
1
Initial address
7
1
0
Initial address is 3E or 3Fh (or
offset from these addresses by
a multiple of 64) and is at
boundary crossing*
1
1
7
Note: Upon power-up or hardware reset the default setting is
continuous.
* In the 8-, 16- and 32-word burst read modes, the address
pointer does not cross 64-word boundaries (addresses
which are multiples of 3Fh).
Burst Active Clock Edge Configuration
By default, the device will deliver data on the rising
edge of the clock after the initial synchronous access
time. Subsequent outputs will also be on the following
rising edges, barring any delays. The device can be set
so that the falling clock edge is active for all synchro-
nous accesses. Address bit A17 determines this set-
ting; “1” for rising active, “0” for falling active.
The autoselect function allows the host system to
determine whether the flash device is enabled for
handshaking. See the “Autoselect Command
Sequence” section on page 36 for more information.
Read Mode Configuration
RDY Configuration
The device supports four different read modes: contin-
uous mode, and 8, 16, and 32 word linear wrap around
modes. A continuous sequence begins at the starting
address and advances the address pointer until the
burst operation is complete. If the highest address in
the device is reached during the continuous burst read
mode, the address pointer wraps around to the lowest
address.
By default, the device is set so that the RDY pin will
output V whenever there is valid data on the outputs.
OH
The device can be set so that RDY goes active one
data cycle before active data. Address bit A18 deter-
mines this setting; “1” for RDY active with data, “0” for
RDY active one clock cycle before valid data. In asyn-
chronous mode, RDY is an open-drain output.
For example, an eight-word linear read with wrap
around begins on the starting address written to the
device and then advances to the next 8 word boundary.
The address pointer then returns to the 1st word after
the previous eight word boundary, wrapping through
Configuration Register
Table 18 shows the address bits that determine the
configuration register settings for various device func-
tions.
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
35
D A T A S H E E T
Table 18. Configuration Register
Address BIt
Function
Settings (Binary)
Set Device
0 = Synchronous Read (Burst Mode) Enabled
A19
Read Mode 1 = Asynchronous Mode (default)
0 = RDY active one clock cycle before data
1 = RDY active with data (default)
A18
A17
RDY
0 = Burst starts and data is output on the falling edge of CLK
1 = Burst starts and data is output on the rising edge of CLK (default)
Clock
Synchronous Mode
00 = Continuous (default)
A16
A15
Read Mode
01 = 8-word linear with wrap around
10 = 16-word linear with wrap around
11 = 32-word linear with wrap around
000 = Data is valid on the 2th active CLK edge after AVD# transition to VIH
001 = Data is valid on the 3th active CLK edge after AVD# transition to VIH
010 = Data is valid on the 4th active CLK edge after AVD# transition to VIH
011 = Data is valid on the 5th active CLK edge after AVD# transition to VIH
100 = Data is valid on the 6th active CLK edge after AVD# transition to VIH
101 = Data is valid on the 7th active CLK edge after AVD# transition to VIH (default)
A14
A13
A12
Programmable
Wait State
110 = Reserved
111 = Reserved
Note:Device will be in the default state upon power-up or hardware reset.
If DQ5 goes high during a program or erase operation,
Reset Command
Writing the reset command resets the banks to the
read or erase-suspend-read mode. Address bits are
don’t cares for this command.
writing the reset command returns the banks to the
read mode (or erase-suspend-read mode if that bank
was in Erase Suspend).
Autoselect Command Sequence
The reset command may be written between the
sequence cycles in an erase command sequence
before erasing begins. This resets the bank to which
the system was writing to the read mode. Once erasure
begins, however, the device ignores reset commands
until the operation is complete.
The autoselect command sequence allows the host
system to access the manufacturer and device codes,
and determine whether or not a sector is protected.
Table 20, “Memory Array Command Definitions,” on
page 46 shows the address and data requirements.
The autoselect command sequence may be written to
an address within a bank that is either in the read or
erase-suspend-read mode. The autoselect command
may not be written while the device is actively program-
ming or erasing in the other bank.
The reset command may be written between the
sequence cycles in a program command sequence
before programming begins (prior to the third cycle).
This resets the bank to which the system was writing to
the read mode. If the program command sequence is
written to a bank that is in the Erase Suspend mode,
writing the reset command returns that bank to the
erase-suspend-read mode. Once programming
begins, however, the device ignores reset commands
until the operation is complete.
The autoselect command sequence is initiated by first
writing two unlock cycles. This is followed by a third
write cycle that contains the bank address and the
autoselect command. The bank then enters the
autoselect mode. No subsequent data will be made
available if the autoselect data is read in synchronous
mode. The system may read at any address within the
same bank any number of times without initiating
another autoselect command sequence. Read com-
mands to other banks will return data from the array.
The following table describes the address require-
ments for the various autoselect functions, and the
resulting data. BA represents the bank address, and
The reset command may be written between the
sequence cycles in an autoselect command sequence.
Once in the autoselect mode, the reset command must
be written to return to the read mode. If a bank entered
the autoselect mode while in the Erase Suspend mode,
writing the reset command returns that bank to the
erase-suspend-read mode.
36
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
SA represents the sector address. The device ID is
read in three cycles.
Table 19. Autoselect Data
next, which in turn initiate the Embedded Program
algorithm. The system is not required to provide further
controls or timings. The device automatically provides
internally generated program pulses and verifies the
programmed cell margin. Table 20, “Memory Array
Command Definitions,” on page 46 shows the address
and data requirements for the program command
sequence.
Description
Address
Read Data
Manufacturer
ID
(BA) + 00h
0001h
Device ID,
Word 1
227Eh (BDS128H)
221Eh (BDS640H)
(BA) + 01h
(BA) + 0Eh
(BA) + 0Fh
When the Embedded Program algorithm is complete,
that bank then returns to the read mode and addresses
are no longer latched. The system can determine the
status of the program operation by monitoring DQ7 or
DQ6/DQ2. Refer to the “Write Operation Status”
section on page 48 for information on these status bits.
Device ID,
Word 2
2218h (BDS128H)
2201h (BDS640H)
Device ID,
Word 3
2200h
Any commands written to the device during the
Embedded Program Algorithm are ignored. Note that a
hardware reset immediately terminates the program
operation. The program command sequence should be
reinitiated once that bank has returned to the read
mode, to ensure data integrity.
Sector
Protection
Verification
0001h (locked),
0000h (unlocked)
(SA) + 02h
DQ15 - DQ8 = 0
DQ7: Factory Lock Bit
1 = Locked, 0 = Not Locked
DQ6: Customer Lock Bit
1 = Locked, 0 = Not Locked
DQ5: Handshake Bit
Programming is allowed in any sequence and across
sector boundaries. A bit cannot be programmed from
“0” back to a “1.” Attempting to do so may cause that
bank to set DQ5 = 1, or cause the DQ7 and DQ6 status
bit to indicate the operation was successful. However,
a succeeding read will show that the data is still “0.”
Only erase operations can convert a “0” to a “1.”
Indicator Bits (BA) + 03h
1 = Reduced Wait-state
Handshake,
0 = Standard Handshake
Unlock Bypass Command Sequence
The unlock bypass feature allows the system to prima-
rily program to a bank faster than using the standard
program command sequence. The unlock bypass
command sequence is initiated by first writing two
unlock cycles. This is followed by a third write cycle
containing the unlock bypass command, 20h. The
device then enters the unlock bypass mode. A
two-cycle unlock bypass program command sequence
is all that is required to program in this mode. The first
cycle in this sequence contains the unlock bypass
program command, A0h; the second cycle contains the
program address and data. Additional data is pro-
grammed in the same manner. This mode dispenses
with the initial two unlock cycles required in the stan-
dard program command sequence, resulting in faster
total programming time. The host system may also ini-
tiate the chip erase and sector erase sequences in the
unlock bypass mode. The erase command sequences
are four cycles in length instead of six cycles. Table 20,
“Memory Array Command Definitions,” on page 46
shows the requirements for the unlock bypass
command sequences. The Unlock Bypass Reset
command is required to return to reading array data
when the bank is in the unlock bypass mode.
The system must write the reset command to return to
the read mode (or erase-suspend-read mode if the
bank was previously in Erase Suspend).
Enter SecSi™ Sector/Exit SecSi Sector
Command Sequence
The SecSi Sector region provides a secured data area
containing a random, eight word electronic serial num-
ber (ESN). The system can access the SecSi Sector
region by issuing the three-cycle Enter SecSi Sector
command sequence. The device continues to access
the SecSi Sector region until the system issues the
four-cycle Exit SecSi Sector command sequence. The
Exit SecSi Sector command sequence returns the de-
vice to normal operation. The SecSi Sector is not ac-
cessible when the device is executing an Embedded
Program or embedded Erase algorithm. Table 20,
“Memory Array Command Definitions,” on page 46
shows the address and data requirements for both
command sequences.
Program Command Sequence
Programming is a four-bus-cycle operation. The
program command sequence is initiated by writing two
unlock write cycles, followed by the program set-up
command. The program address and data are written
During the unlock bypass mode, only the Read, Unlock
Bypass Program, Unlock Bypass Sector Erase, Unlock
Bypass Chip Erase, and Unlock Bypass Reset com-
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
37
D A T A S H E E T
mands are valid. To exit the unlock bypass mode, the
command, which in turn invokes the Embedded Erase
algorithm. The device does not require the system to
preprogram prior to erase. The Embedded Erase algo-
rithm automatically preprograms and verifies the entire
memory for an all zero data pattern prior to electrical
erase. The system is not required to provide any con-
trols or timings during these operations. Table 20,
“Memory Array Command Definitions,” on page 46
shows the address and data requirements for the chip
erase command sequence.
system must issue the two-cycle unlock bypass reset
command sequence. The first cycle must contain the
bank address and the data 90h. The second cycle
need only contain the data 00h. The bank then returns
to the read mode.
The device offers accelerated program operations
through the ACC input. When the system asserts V
HH
on this input, the device automatically enters the
Unlock Bypass mode. The system may then write the
two-cycle Unlock Bypass program command
sequence. The device uses the higher voltage on the
ACC input to accelerate the operation.
When the Embedded Erase algorithm is complete, that
bank returns to the read mode and addresses are no
longer latched. The system can determine the status of
the erase operation by using DQ7 or DQ6/DQ2. Refer
to the “Write Operation Status” section on page 48 for
information on these status bits.
Figure 4, “Program Operation,” on page 38 illustrates
the algorithm for the program operation. Refer to the
Erase/Program Operations table in the AC Character-
istics section for parameters, and Figure 34, “Asyn-
chronous Program Operation Timings: AVD# Latched
Addresses,” on page 70 and Figure 36, “Synchronous
Program Operation Timings: WE# Latched Addresses,”
on page 72 for timing diagrams.
Any commands written during the chip erase operation
are ignored. However, note that a hardware reset
immediately terminates the erase operation. If that
occurs, the chip erase command sequence should be
reinitiated once that bank has returned to reading array
data, to ensure data integrity.
The host system may also initiate the chip erase
command sequence while the device is in the unlock
bypass mode. The command sequence is two cycles
cycles in length instead of six cycles. See Table 20,
“Memory Array Command Definitions,” on page 46 for
details on the unlock bypass command sequences.
START
Write Program
Command Sequence
Figure 5, “Erase Operation,” on page 40 illustrates the
algorithm for the erase operation. Refer to the
Erase/Program Operations table in the AC Character-
istics section for parameters and timing diagrams.
Data Poll
from System
Embedded
Program
algorithm
in progress
Sector Erase Command Sequence
Verify Data?
No
Sector erase is a six bus cycle operation. The sector
erase command sequence is initiated by writing two
unlock cycles, followed by a set-up command. Two
additional unlock cycles are written, and are then fol-
lowed by the address of the sector to be erased, and
the sector erase command. Table 20, “Memory Array
Command Definitions,” on page 46 shows the address
and data requirements for the sector erase command
sequence.
Yes
No
Increment Address
Last Address?
Yes
Programming
Completed
The device does not require the system to preprogram
prior to erase. The Embedded Erase algorithm auto-
matically programs and verifies the entire memory for
an all zero data pattern prior to electrical erase. The
system is not required to provide any controls or
timings during these operations.
Note: See Table 20 for program command sequence.
Figure 4. Program Operation
After the command sequence is written, a sector erase
Chip Erase Command Sequence
time-out of no less than t
occurs. During the
SEA
Chip erase is a six bus cycle operation. The chip erase
command sequence is initiated by writing two unlock
cycles, followed by a set-up command. Two additional
unlock write cycles are then followed by the chip erase
time-out period, additional sector addresses and sector
erase commands may be written. Loading the sector
erase buffer may be done in any sequence, and the
38
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
number of sectors may be from one sector to all sec-
tors. The time between these additional cycles must be
less than t , otherwise erasure may begin. Any
Erase Suspend/Erase Resume Commands
The Erase Suspend command, B0h, allows the system
to interrupt a sector erase operation and then read data
from, or program data to, any sector not selected for
erasure. The bank address is required when writing
this command. This command is valid only during the
SEA
sector erase address and command following the
exceeded time-out, t may or may not be accepted.
SEA,
It is recommended that processor interrupts be dis-
abled during this time to ensure all commands are
accepted. The interrupts can be re-enabled after the
last Sector Erase command is written. Any command
other than Sector Erase or Erase Suspend during the
time-out period resets that bank to the read mode. The
system must rewrite the command sequence and any
additional addresses and commands.
sector erase operation, including the minimum t
SEA
time-out period during the sector erase command
sequence. The Erase Suspend command is ignored if
written during the chip erase operation or Embedded
Program algorithm.
When the Erase Suspend command is written during
the sector erase operation, the device requires a
The system can monitor DQ3 to determine if the sector
erase timer has timed out (See “DQ3: Sector Erase
Timer” section on page 51.) The time-out begins from
the rising edge of the final WE# pulse in the command
sequence.
maximum of t
to suspend the erase operation. How-
ESL
ever, when the Erase Suspend command is written
during the sector erase time-out, the device immedi-
ately terminates the time-out period and suspends the
erase operation.
When the Embedded Erase algorithm is complete, the
bank returns to reading array data and addresses are
no longer latched. Note that while the Embedded Erase
operation is in progress, the system can read data from
the non-erasing bank. The system can determine the
status of the erase operation by reading DQ7 or
DQ6/DQ2 in the erasing bank. Refer to the “Write
Operation Status” section on page 48 for information
on these status bits.
After the erase operation has been suspended, the
bank enters the erase-suspend-read mode. The
system can read data from or program data to any
sector not selected for erasure. (The device “erase sus-
pends” all sectors selected for erasure.) Reading at any
address within erase-suspended sectors produces
status information on DQ7–DQ0. The system can use
DQ7, or DQ6 and DQ2 together, to determine if a
sector is actively erasing or is erase-suspended. Refer
to the Figure , “Write Operation Status,” on page 48 for
information on these status bits.
Once the sector erase operation has begun, only the
Erase Suspend command is valid. All other commands
are ignored. However, note that a hardware reset
immediately terminates the erase operation. If that
occurs, the sector erase command sequence should
be reinitiated once that bank has returned to reading
array data, to ensure data integrity.
After an erase-suspended program operation is com-
plete, the bank returns to the erase-suspend-read
mode. The system can determine the status of the
program operation using the DQ7 or DQ6 status bits,
just as in the standard program operation. Refer to the
“Write Operation Status” section on page 48 for more
information.
The host system may also initiate the sector erase
command sequence while the device is in the unlock
bypass mode. The command sequence is four cycles
cycles in length instead of six cycles. The Unlock
Bypass Reset Command is required to return to
reading array data when the bank is in the unlock
bypass mode.
In the erase-suspend-read mode, the system can also
issue the autoselect command sequence. Refer to the
“Autoselect Mode” section on page 14 and “Autoselect
Command Sequence” section on page 36 for details.
To resume the sector erase operation, the system must
write the Erase Resume command. The bank address
of the erase-suspended bank is required when writing
this command. Further writes of the Resume command
Figure 5, “Erase Operation,” on page 40 illustrates the
algorithm for the erase operation. Refer to the
Erase/Program Operations table in the Figure , “AC
Characteristics,” on page 69 for parameters and timing
diagrams.
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
39
D A T A S H E E T
are ignored. Another Erase Suspend command can be
written after the chip has resumed erasing.
ing as a “0”. The password is all Fs when shipped from
the factory. All 64-bit password combinations are valid
as a password.
START
Password Verify Command
The Password Verify Command is used to verify the
Password. The Password is verifiable only when the
Password Mode Locking Bit is not programmed. If the
Password Mode Locking Bit is programmed and the
user attempts to verify the Password, the device will al-
ways drive all Fs onto the DQ data bus.
Write Erase
Command Sequence
Data Poll
from System
Also, the device will not operate in Simultaneous Oper-
ation when the Password Verify command is executed.
Only the password is returned regardless of the bank
address. The lower two address bits (A1–A0) are valid
during the Password Verify. Writing the SecSi Sector
Exit command returns the device back to normal oper-
ation.
Embedded
Erase
algorithm
in progress
No
Data = FFh?
Yes
Password Protection Mode Locking Bit
Program Command
Erasure Completed
The Password Protection Mode Locking Bit Program
Command programs the Password Protection Mode
Locking Bit, which prevents further verifies or updates
to the password. Once programmed, the Password
Protection Mode Locking Bit cannot be erased and the
Persistent Protection Mode Locking Bit program cir-
cuitry is disabled, thereby forcing the device to remain
in the Password Protection Mode. After issuing
“PL/68h” at the fourth bus cycle, the device requires a
time out period of approximately 150 µs for program-
ming the Password Protection Mode Locking Bit. Then
by writing “PL/48h” at the fifth bus cycle, the device
outputs verify data at DQ0. If DQ0 = 1, then the Pass-
word Protection Mode Locking Bit is programmed. If
not, the system must repeat this program sequence
from the fourth cycle of “PL/68h”. Exiting the Password
Protection Mode Locking Bit Program command is ac-
complished by writing the SecSi Sector Exit command
or Read/Reset command.
Notes:
1. See Table 20 for erase command sequence.
2. See the section on DQ3 for information on the sector
erase timer.
Figure 5. Erase Operation
Password Program Command
The Password Program Command permits program-
ming the password that is used as part of the hard-
ware protection scheme. The actual password is
64-bits long. 4 Password Program commands are re-
quired to program the password. The user must enter
the unlock cycle, password program command (38h)
and the program address/data for each portion of the
password when programming. There are no provisions
for entering the 2-cycle unlock cycle, the password
program command, and all the password data. There
is no special addressing order required for program-
ming the password. Also, when the password is under-
going programming, Simultaneous Operation is
disabled. Read operations to any memory location will
return the programming status. Once programming is
complete, the user must issue a Read/Reset com-
mand to return the device to normal operation. Once
the Password is written and verified, the Password
Mode Locking Bit must be set in order to prevent verifi-
cation. The Password Program Command is only ca-
pable of programming “0”s. Programming a “1” after a
cell is programmed as a “0” results in a time-out by the
Embedded Program Algorithm™ with the cell remain-
Persistent Sector Protection Mode
Locking Bit Program Command
The Persistent Sector Protection Mode Locking Bit
Program Command programs the Persistent Sector
Protection Mode Locking Bit, which prevents the Pass-
word Mode Locking Bit from ever being programmed.
By disabling the program circuitry of the Password
Mode Locking Bit, the device is forced to remain in the
Persistent Sector Protection mode of operation, once
this bit is set. After issuing “SMPL/68h” at the fourth
bus cycle, the device requires a time out period of ap-
proximately 150 µs for programming the Persistent
Protection Mode Locking Bit. Then by writing
“SMPL/48h” at the fifth bus cycle, the device outputs
verify data at DQ0. If DQ0 = 1, then the Persistent Pro-
40
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
tection Mode Locking Bit is programmed. If not, the command is accomplished by writing the Read/Reset
system must repeat this program sequence from the
fourth cycle of “PL/68h”. Exiting the Persistent Protec-
tion Mode Locking Bit Program command is accom-
plished by writing the SecSi Sector Exit command or
Reset command.
command.
Password Unlock Command
The Password Unlock command is used to clear the
PPB Lock Bit so that the PPBs can be unlocked for
modification, thereby allowing the PPBs to become ac-
cessible for modification. The exact password must be
entered in order for the unlocking function to occur.
This command cannot be issued any faster than 2 µs
at a time to prevent a hacker from running through the
all 64-bit combinations in an attempt to correctly match
a password. If the command is issued before the 2 µs
execution window for each portion of the unlock, the
command will be ignored.
SecSi Sector Protection Bit Program
Command
To protect the SecSi Sector, write the SecSi Sector
Protect command sequence while in the SecSi Sector
mode. After issuing “OPBP/48h” at the fourth bus cy-
cle, the device requires a time out period of approxi-
mately 150 µs to protect the SecSi Sector. Then, by
writing “OPBP/48” at the fifth bus cycle, the device out-
puts verify data at DQ0. If DQ0 = 1, then the SecSi
Sector is protected. If not, then the system must re-
peat this program sequence from the fourth cycle of
“OPBP/48h”.
The Password Unlock function is accomplished by
writing Password Unlock command and data to the de-
vice to perform the clearing of the PPB Lock Bit. The
password is 64 bits long, so the user must write the
Password Unlock command 4 times. A1 and A0 are
used for matching. Writing the Password Unlock com-
mand is not address order specific. The lower address
A1–A0= 00, the next Password Unlock command is to
A1–A0= 01, then to A1–A0= 10, and finally to A1–A0=
11.
PPB Lock Bit Set Command
The PPB Lock Bit Set command is used to set the
PPB Lock bit if it is cleared either at reset or if the
Password Unlock command was successfully exe-
cuted. There is no PPB Lock Bit Clear command.
Once the PPB Lock Bit is set, it cannot be cleared un-
less the device is taken through a power-on clear or
the Password Unlock command is executed. Upon set-
ting the PPB Lock Bit, the PPBs are latched into the
DYBs. If the Password Mode Locking Bit is set, the
PPB Lock Bit status is reflected as set, even after a
power-on reset cycle. Exiting the PPB Lock Bit Set
command is accomplished by writing the SecSi Sector
Exit command, only while in the Persistent Sector Pro-
tection Mode.
Once the Password Unlock command is entered for all
four words, the RDY pin goes LOW indicating that the
device is busy. Approximately 1 µs is required for each
portion of the unlock. Once the first portion of the
password unlock completes (RDY is not driven and
DQ6 does not toggle when read), the Password Un-
lock command is issued again, only this time with the
next part of the password. Four Password Unlock com-
mands are required to successfully clear the PPB
Lock Bit. As with the first Password Unlock command,
the RDY signal goes LOW and reading the device re-
sults in the DQ6 pin toggling on successive read oper-
ations until complete. It is the responsibility of the
microprocessor to keep track of the number of Pass-
word Unlock commands, the order, and when to read
the PPB Lock bit to confirm successful password un-
lock. In order to relock the device into the Password
Mode, the PPB Lock Bit Set command can be re-is-
sued. Exiting the Password Unlock Command is ac-
complished by writing SecSi Sector Exit command.
DYB Write Command
The DYB Write command is used to set or clear a DYB
for a given sector. The high order address bits
(Amax–A11) are issued at the same time as the code
01h or 00h on DQ7-DQ0. All other DQ data bus pins
are ignored during the data write cycle. The DYBs are
modifiable at any time, regardless of the state of the
PPB or PPB Lock Bit. The DYBs are cleared at
power-up or hardware reset. Exiting the DYB Write
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
41
D A T A S H E E T
Figure 6. PPB Program Algorithm
Am29BDS128H/Am29BDS640H
42
27024B3 May 10, 2006
D A T A S H E E T
ing a specific PPB. Unlike the PPB program, no spe-
PPB Program Command
cific sector address is required. However, when the
PPB erase command is written (60h), all Sector PPBs
are erased in parallel. If the PPB Lock Bit is set, the
ALL PPB Erase command will not execute and the
command will time-out without erasing the PPBs. After
issuing “WP/60h” at the fourth bus cycle, the device re-
quires a time out period of approximately 1.5 ms to
erase the PPB. Writing “SBA+WP/40h” at the fifth bus
cycle produces verify data at DQ0. If DQ0 = 0, the
PPB is erased. If not, the system must repeat this pro-
gram sequence from the fourth cycle of “WP/60h”.
The PPB Program command is used to program, or
set, a given PPB. Each PPB is individually pro-
grammed (but is bulk erased with the other PPBs).
The specific sector address (Amax–A12) are written at
the same time as the program command 60h. If the
PPB Lock Bit is set and the correspondingly PPB is
set for the sector, the PPB Program command will not
execute and the command will time out without pro-
gramming the PPB. After issuing “SBA+WP/68h” at
the fourth bus cycle, the device requires a time out pe-
riod of approximately 150 µs to program the PPB.
Writing “SBA+WP/48” at the fifth bus cycle produces
verify data at DQ0. If DQ0 = 1, the PPB is pro-
grammed. If not, the system must repeat this program
sequence from the fourth cycle of “SBA+WP/68h”.
It is the responsibility of the system to preprogram all
PPBs prior to issuing the All PPB Erase command. If
the system attempts to erase a cleared PPB, over-era-
sure may occur, making it difficult to program the PPB
at a later time. Also note that the total number of PPB
program/erase cycles is limited to 100 cycles. Cycling
the PPBs beyond 100 cycles is not guaranteed.
The PPB Program command does not follow the
Embedded Program algorithm. Writing the SecSi
Sector Exit command or Read/Reset command return
the device back to normal operation.
Writing the SecSi Sector Exit command or Read/Re-
set command return the device to normal operation.
All PPB Erase Command
The All PPB Erase command is used to erase all
PPBs in bulk. There is no means for individually eras-
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
43
D A T A S H E E T
Figure 7. PPB Erase Algorithm
Am29BDS128H/Am29BDS640H
44
27024B3 May 10, 2006
D A T A S H E E T
tor Exit command return the device to normal opera-
DYB Write Command
tion.
The DYB Write command is used for setting the DYB,
which is a volatile bit that is cleared at hardware reset.
There is one DYB per sector. If the PPB is set, the sec-
tor is protected regardless of the value of the DYB. If
the PPB is cleared, setting the DYB to a 1 protects the
sector from programs or erases. Since this is a volatile
bit, removing power or resetting the device will clear
the DYBs. Writing Read/Reset command returns the
device to normal operations.
PPB Lock Bit Status Command
The programming of the PPB Lock Bit for a given sec-
tor can be verified by writing a PPB Lock Bit status ver-
ify command to the device. Read/Reset and SecSi
Sector Exit return the device to normal operation.
DYB Status Command
The programming of the DYB for a given sector can be
verified by writing a DYB Status command to the de-
vice. Writing SecSi Sector Exit command returns the
device to normal operation.
PPB Status Command
The programming of the PPB for a given sector can be
verified by writing a PPB status verify command to the
device. Writing Read/Reset command and SecSi Sec-
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
45
D A T A S H E E T
Command Definitions
Table 20. Memory Array Command Definitions
Bus Cycles (Notes 1–6)
First
Addr
Second
Third
Addr
Fourth
Addr
Fifth
Sixth
Addr
Command Sequence
(Notes)
Data
RD
F0
Addr
Data
Data
Data
Addr
Data
Data
Asynchronous Read (7)
Reset (8)
1
1
4
6
4
4
4
6
6
3
2
2
2
1
2
1
1
3
1
RA
XXX
555
555
555
555
555
555
555
555
XX
Manufacturer ID
Device ID (9, 10)*
Sector Lock Verify (12)*
Indicator Bits (13)*
Program
AA
AA
AA
AA
AA
AA
AA
AA
A0
80
2AA
2AA
2AA
2AA
2AA
2AA
2AA
2AA
PA
55
55
55
55
55
55
55
55
PD
30
10
BA+555
BA+555
SA+555
BA+555
555
90
90
90
90
A0
80
80
20
BA+X00
BA+X01
SA+X02
BA+X03
PA
0001
227E
(12)*
(13)*
Data
AA
BA+X0E
(10)*
BA+X0F
(11)*
Chip Erase
555
555
2AA
2AA
55
55
555
SA
10
30
Sector Erase
555
555
AA
Entry
555
Program (14, 15)
Sector Erase (14, 15)
Erase (14, 15)
XX
SA
XX
80
XXX
CFI (14, 15)
XX
98
Reset (20)
XX
90
XXX
2AA
00
55
Erase Suspend (16)
Erase Resume (17)
Set Configuration Register (18)
CFI Query (19)
BA
B0
30
BA
555
55
AA
98
(CR)555
C0
* For actual hexadecimal data values, refer to the note number indicated.
Legend:
X = Don’t care
SA = Address of the sector to be verified (in autoselect mode) or erased.
Address bits Amax–A12 uniquely select any sector.
BA = Address of the bank (BDS128H: A22–A20; BDS640H: A21–A19) for
which command is being written.
SLA = Address of the sector to be locked. Set sector address (SA) and
either A6 = 1 for unlocked or A6 = 0 for locked.
RA = Address of the memory location to be read.
RD = Data read from location RA during read operation.
PA = Address of the memory location to be programmed. Addresses latch
on the rising edge of the AVD# pulse or active edge of CLK which ever
comes first.
PD = Data to be programmed at location PA. Data latches on the rising
edge of WE# or CE# pulse, whichever happens first.
CR = Configuration Register address bits A19–A12.
Notes:
1. See Table 1 for description of bus operations.
13. DQ15–DQ8 = 0, DQ7: Factory Lock Bit (1 = Locked, 0 = Not
Locked), DQ6: Customer Lock Bit (1 = Locked, 0 = Not Locked),
DQ5: Handshake Bit (1 = Reduced wait-state Handshake, 0 =
Standard Handshake), DQ4–DQ0 = 0
2. All values are in hexadecimal.
3. Shaded cells indicate read cycles. All others are write cycles.
4. Data bits DQ15–DQ8 are don’t care in command sequences, except
for RD and PD.
14. The Unlock Bypass command sequence is required prior to this
command sequence.
5. Unless otherwise noted, address bits Amax–A12 are don’t cares.
15. The Unlock Bypass Reset command is required to return to reading
array data when the bank is in the unlock bypass mode.
6. Writing incorrect address and data values or writing them in the
improper sequence may place the device in an unknown state. The
system must write the reset command to return the device to
reading array data.
16. The system may read and program in non-erasing sectors, or enter
the autoselect mode, when in the Erase Suspend mode. The Erase
Suspend command is valid only during a sector erase operation,
and requires the bank address.
7. No unlock or command cycles required when bank is reading array
data.
17. The Erase Resume command is valid only during the Erase
Suspend mode, and requires the bank address.
8. The Reset command is required to return to reading array data (or to
the erase-suspend-read mode if previously in Erase Suspend) when
a bank is in the autoselect mode, or if DQ5 goes high (while the
bank is providing status information) or performing sector
lock/unlock.
18. See “Set Configuration Register Command Sequence” for details.
This command is unavailable in Unlock Bypass mode.
19. Command is valid when device is ready to read array data or when
device is in autoselect mode.
9. The fourth cycle of the autoselect command sequence is a read
cycle. The system must provide the bank address. See the
Autoselect Command Sequence section for more information.
20. The Unlock Bypass Reset command is required to exit this mode
before sending any other commands to the device. The only
commands that are allowed in the Unlock Bypass mode are the
Entry and exit (Reset), Program, Erase, Sector Erase and CFI.
10. BDS128H: 2218h; BDS640H: 221Eh.
11. BDS128H: 2200h; BDS640H: 2201h
12. The data is 0000h for an unlocked sector and 0001h for a locked
sector
46
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
Table 21. Sector Protection Command Definitions
Bus Cycles (Notes 1–6)
First
Second
Third
Addr
Fourth
Fifth
Addr
Sixth
Data Addr Data
Seventh
Command Sequence
(Notes)
Addr Data Addr Data
Data
88
Addr
Data
Addr Data
Entry
Exit
3
4
555
555
AA
AA
2AA
2AA
55
55
555
555
90
XX
00
68
Protection Bit
Program (8, 9)
6
555
AA
2AA
55
555
60
SA+OW
SA+OW
48
OW
RD(0)
Program (11)
Verify (11)
4
4
7
6
555
555
555
555
AA
AA
AA
AA
2AA
2AA
2AA
2AA
55
55
55
55
555
555
555
555
38
C8
28
60
XX[0–3]
XX[0–3]
XX0
PD[0–3]
PD[0–3]
PD0
Unlock (11)
Program (8, 9)
XX1
PD1
48
XX2
XX
PD2
XX3
PD3
SBA+WP
68
SBA+WP
RD(0)
All Erase
SBA+
WPE
6
555
AA
2AA
55
555
60
WPE
60
40
XX
RD(0)
(8, 10, 12)
Status (13)
Set
4
3
4
4
4
4
555
555
555
555
555
555
AA
AA
AA
AA
AA
AA
2AA
2AA
2AA
2AA
2AA
2AA
55
55
55
55
55
55
BA+555
555
90
78
58
48
48
58
SBA+WP
RD(0)
Status (8)
Write
BA+555
555
SA
SA
SA
SA
RD(1)
X1
Erase
555
X0
Status
BA+555
RD(0)
Locking Bit Program
(8, 9)
6
6
555
555
AA
AA
2AA
2AA
55
55
555
555
60
60
PL
SL
68
68
PL
SL
48
48
PL
SL
RD(0)
RD(0)
Locking Bit Program
(8, 9)
Legend:
X = Don’t care
PWA = Password Address. Address bits A1 and A0 are used to select
each 16-bit portion of the 64-bit entity.
PA = Address of the memory location to be programmed. Addresses latch
on the rising edge of the AVD# pulse or active edge of CLK which ever
comes first.
PL = Address (A7–A0) is (00001010)
RD(0) = DQ0 protection indicator bit. If protected, DQ0 = 1.
If unprotected, DQ0 = 0.
SA = Address of the sector to be verified (in autoselect mode) or erased.
Address bits Amax–A12 uniquely select any sector.
RD(1) = DQ1 protection indicator bit. If protected, DQ1 = 1.
If unprotected, DQ1 = 0.
BA = Address of the bank (BDS128H: A22–A20; BDS640H: A21–A19) for
which command is being written.
SBA = Sector address block to be protected.
SL = Address (A7–A0) is (00010010)
SLA = Address of the sector to be locked. Set sector address (SA) and
either A6 = 1 for unlocked or A6 = 0 for locked.
WD= Write Data. See “Configuration Register” definition for specific write
data
OW = Address (A7–A0) is (00011010).
PD3–PD0 = Password Data. PD3–PD0 present four 16 bit combinations
that represent the 64-bit password.
WP = Address (A7–A0) is (00000010)
WPE = Address (A7–A0) is (01000010)
Notes:
1. See Table 1 for description of bus operations.
9. The fourth cycle programs the addressed locking bit. The fifth and
sixth cycles are used to validate whether the bit has been fully
programmed. If DQ0 (in the sixth cycle) reads 0, the program
command must be issued and verified again.
2. All values are in hexadecimal.
3. Shaded cells indicate read cycles. All others are write cycles.
4. Data bits DQ15–DQ8 are don’t care in command sequences, except
for RD, PD, WD, PWD, and PD3–PD0.
10. The fourth cycle erases all PPBs. The fifth and sixth cycles are used
to validate whether the bits have been fully erased. If DQ0 (in the
sixth cycle) reads 1, the erase command must be issued and verified
again.
5. Unless otherwise noted, address bits Amax–A12 are don’t cares.
6. Writing incorrect address and data values or writing them in the
improper sequence may place the device in an unknown state. The
system must write the reset command to return the device to
reading array data.
11. The entire four bus-cycle sequence must be entered for each portion
of the password.
12. Before issuing the erase command, all PPBs should be programmed
in order to prevent over-erasure of PPBs.
7. No unlock or command cycles required when bank is reading array
data.
13. In the fourth cycle, 01h indicates PPB set; 00h indicates PPB not
set.
8. Not supported in Synchronous Read Mode, command mode verify
are always asynchronous read operations.
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
47
D A T A S H E E T
WRITE OPERATION STATUS
The device provides several bits to determine the
status of a program or erase operation: DQ2, DQ3,
DQ5, DQ6, and DQ7. Table 23, “Write Operation
Status,” on page 52 and the following subsections
describe the function of these bits. DQ7 and DQ6 each
offers a method for determining whether a program or
erase operation is complete or in progress.
invalid. Valid data on DQ7-DQ0 will appear on succes-
sive read cycles.
Table 23, “Write Operation Status,” on page 52 shows
the outputs for Data# Polling on DQ7. Figure 8, “Data#
Polling Algorithm,” on page 48 shows the Data# Polling
algorithm. Figure 40, “Data# Polling Timings
(During Embedded Algorithm),” on page 76 in the AC
Characteristics section shows the Data# Polling timing
diagram.
DQ7: Data# Polling
The Data# Polling bit, DQ7, indicates to the host
system whether an Embedded Program or Erase algo-
rithm is in progress or completed, or whether a bank is
in Erase Suspend. Data# Polling is valid after the rising
edge of the final WE# pulse in the command sequence.
During the Embedded Program algorithm, the device
outputs on DQ7 the complement of the datum pro-
grammed to DQ7. This DQ7 status also applies to pro-
gramming during Erase Suspend. When the
Embedded Program algorithm is complete, the device
outputs the datum programmed to DQ7. The system
must provide the program address to read valid status
information on DQ7. If a program address falls within a
protected sector, Data# Polling on DQ7 is active for
approximately t , then that bank returns to the read
PSP
mode.
During the Embedded Erase algorithm, Data# Polling
produces a “0” on DQ7. When the Embedded Erase
algorithm is complete, or if the bank enters the Erase
Suspend mode, Data# Polling produces a “1” on DQ7.
The system must provide an address within any of the
sectors selected for erasure to read valid status infor-
mation on DQ7.
After an erase command sequence is written, if all
sectors selected for erasing are protected, Data#
Polling on DQ7 is active for approximately t , then the
ASP
bank returns to the read mode. If not all selected
sectors are protected, the Embedded Erase algorithm
erases the unprotected sectors, and ignores the
selected sectors that are protected. However, if the
system reads DQ7 at an address within a protected
sector, the status may not be valid.
Just prior to the completion of an Embedded Program
or Erase operation, DQ7 may change asynchronously
with DQ6–DQ0 while Output Enable (OE#) is asserted
low. That is, the device may change from providing
status information to valid data on DQ7. Depending on
when the system samples the DQ7 output, it may read
the status or valid data. Even if the device has com-
pleted the program or erase operation and DQ7 has
valid data, the data outputs on DQ6-DQ0 may be still
Notes:
1. VA = Valid address for programming. During a sector
erase operation, a valid address is any sector address
within the sector being erased. During chip erase, a valid
address is any non-protected sector address.
2. DQ7 should be rechecked even if DQ5 = “1” because
DQ7 may change simultaneously with DQ5.
Figure 8. Data# Polling Algorithm
48
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
cause DQ6 to toggle. When the operation is complete,
RDY: Ready
DQ6 stops toggling.
The RDY is a dedicated output that, when the device is
configured in the Synchronous mode, indicates (when
at logic low) the system should wait 1 clock cycle before
expecting the next word of data. The RDY pin is only
controlled by CE#. Using the RDY Configuration
Command Sequence, RDY can be set so that a logic
low indicates the system should wait 2 clock cycles
before expecting valid data.
After an erase command sequence is written, if all
sectors selected for erasing are protected, DQ6 toggles
for approximately t
time, then returns to reading array data. If not all
selected sectors are protected, the Embedded Erase
algorithm erases the unprotected sectors, and ignores
the selected sectors that are protected.
, all sectors protected toggle
ASP
The following conditions cause the RDY output to be
low: during the initial access (in burst mode), and after
the boundary that occurs every 64 words beginning
with the 64th address, 3Fh.
The system can use DQ6 and DQ2 together to deter-
mine whether a sector is actively erasing or is
erase-suspended. When the device is actively erasing
(that is, the Embedded Erase algorithm is in progress),
DQ6 toggles. When the device enters the Erase
Suspend mode, DQ6 stops toggling. However, the
system must also use DQ2 to determine which sectors
are erasing or erase-suspended. Alternatively, the
system can use DQ7 (see the subsection on DQ7:
Data# Polling).
When the device is configured in Asynchronous Mode,
the RDY is an open-drain output pin which indicates
whether an Embedded Algorithm is in progress or com-
pleted. The RDY status is valid after the rising edge of
the final WE# pulse in the command sequence.
If the output is low (Busy), the device is actively erasing
or programming. (This includes programming in the
Erase Suspend mode.) If the output is in high imped-
ance (Ready), the device is in the read mode, the
standby mode, or in the erase-suspend-read mode.
Table 23, “Write Operation Status,” on page 52 shows
the outputs for RDY.
If a program address falls within a protected sector,
DQ6 toggles for approximately t
after the program
PSP
command sequence is written, then returns to reading
array data.
DQ6 also toggles during the erase-suspend-program
mode, and stops toggling once the Embedded
Program algorithm is complete.
DQ6: Toggle Bit I
See the following for additional information: Figure 9,
“Toggle Bit Algorithm,” on page 50, “DQ6: Toggle Bit I”
on page 49, Figure 41, “Toggle Bit Timings
(During Embedded Algorithm),” on page 76 (toggle bit
timing diagram), and Table 22, “DQ6 and DQ2 Indica-
tions,” on page 51.
Toggle Bit I on DQ6 indicates whether an Embedded
Program or Erase algorithm is in progress or complete,
or whether the device has entered the Erase Suspend
mode. Toggle Bit I may be read at any address in the
same bank, and is valid after the rising edge of the final
WE# pulse in the command sequence (prior to the
program or erase operation), and during the sector
erase time-out.
Toggle Bit I on DQ6 requires either OE# or CE# to be
deasserted and reasserted to show the change in
state.
During an Embedded Program or Erase algorithm
operation, successive read cycles to any address
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
49
D A T A S H E E T
DQ2: Toggle Bit II
The “Toggle Bit II” on DQ2, when used with DQ6, indi-
cates whether a particular sector is actively erasing
(that is, the Embedded Erase algorithm is in progress),
or whether that sector is erase-suspended. Toggle Bit
II is valid after the rising edge of the final WE# pulse in
the command sequence.
START
Read Byte
(DQ7-DQ0)
Address = VA
DQ2 toggles when the system reads at addresses
within those sectors that have been selected for era-
sure. But DQ2 cannot distinguish whether the sector is
actively erasing or is erase-suspended. DQ6, by com-
parison, indicates whether the device is actively
erasing, or is in Erase Suspend, but cannot distinguish
which sectors are selected for erasure. Thus, both
status bits are required for sector and mode informa-
tion. Refer to Table 22, “DQ6 and DQ2 Indications,” on
page 51 to compare outputs for DQ2 and DQ6.
Read Byte
(DQ7-DQ0)
Address = VA
No
DQ6 = Toggle?
Yes
See the following for additional information: Figure 9,
“Toggle Bit Algorithm,” on page 50, “DQ6: Toggle Bit I”
on page 49, Figure 41, “Toggle Bit Timings
(During Embedded Algorithm),” on page 76, and
Table 22, “DQ6 and DQ2 Indications,” on page 51.
No
DQ5 = 1?
Yes
Read Byte Twice
(DQ7-DQ0)
Adrdess = VA
No
DQ6 = Toggle?
Yes
FAIL
PASS
Note:The system should recheck the toggle bit even if DQ5 =
“1” because the toggle bit may stop toggling as DQ5 changes
to “1.” See the subsections on DQ6 and DQ2 for more
information.
Figure 9. Toggle Bit Algorithm
50
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
Table 22. DQ6 and DQ2 Indications
If device is
and the system reads
then DQ6
and DQ2
programming,
at any address,
toggles,
does not toggle.
at an address within a sector
selected for erasure,
toggles,
toggles,
also toggles.
does not toggle.
toggles.
actively erasing,
at an address within sectors not
selected for erasure,
at an address within a sector
selected for erasure,
does not toggle,
returns array data,
toggles,
erase suspended,
at an address within sectors not
returns array data. The system can read
from any sector not selected for erasure.
selected for erasure,
programming in
erase suspend
at any address,
is not applicable.
Reading Toggle Bits DQ6/DQ2
DQ5: Exceeded Timing Limits
Refer to Figure 9, “Toggle Bit Algorithm,” on page 50 for
the following discussion. Whenever the system initially
begins reading toggle bit status, it must read DQ7–DQ0
at least twice in a row to determine whether a toggle bit
is toggling. Typically, the system would note and store
the value of the toggle bit after the first read. After the
second read, the system would compare the new value
of the toggle bit with the first. If the toggle bit is not tog-
gling, the device has completed the program or erase
operation. The system can read array data on
DQ7–DQ0 on the following read cycle.
DQ5 indicates whether the program or erase time has
exceeded a specified internal pulse count limit. Under
these conditions DQ5 produces a “1,” indicating that
the program or erase cycle was not successfully com-
pleted.
The device may output a “1” on DQ5 if the system tries
to program a “1” to a location that was previously pro-
grammed to “0.” Only an erase operation can change a
“0” back to a “1.” Under this condition, the device halts
the operation, and when the timing limit has been
exceeded, DQ5 produces a “1.”
However, if after the initial two read cycles, the system
determines that the toggle bit is still toggling, the
system also should note whether the value of DQ5 is
high (see the section on DQ5). If it is, the system
should then determine again whether the toggle bit is
toggling, since the toggle bit may have stopped tog-
gling just as DQ5 went high. If the toggle bit is no longer
toggling, the device has successfully completed the
program or erase operation. If it is still toggling, the
device did not completed the operation successfully,
and the system must write the reset command to return
to reading array data.
Under both these conditions, the system must write the
reset command to return to the read mode (or to the
erase-suspend-read mode if a bank was previously in
the erase-suspend-program mode).
DQ3: Sector Erase Timer
After writing a sector erase command sequence, the
system may read DQ3 to determine whether or not
erasure has begun. (The sector erase timer does not
apply to the chip erase command.) If additional sectors
are selected for erasure, the entire time-out also
applies after each additional sector erase command.
When the time-out period is complete, DQ3 switches
from a “0” to a “1.” If the time between additional sector
erase commands from the system can be assumed to
The remaining scenario is that the system initially
determines that the toggle bit is toggling and DQ5 has
not gone high. The system may continue to monitor the
toggle bit and DQ5 through successive read cycles,
determining the status as described in the previous
paragraph. Alternatively, it may choose to perform
other system tasks. In this case, the system must start
at the beginning of the algorithm when it returns to
determine the status of the operation (Figure 9, “Toggle
Bit Algorithm,” on page 50).
be less than t
, the system need not monitor DQ3.
SEA
See also “Sector Erase Command Sequence” on
page 38.
After the sector erase command is written, the system
should read the status of DQ7 (Data# Polling) or DQ6
(Toggle Bit I) to ensure that the device has accepted
the command sequence, and then read DQ3. If DQ3 is
“1,” the Embedded Erase algorithm has begun; all
further commands (except Erase Suspend) are ignored
until the erase operation is complete. If DQ3 is “0,” the
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
51
D A T A S H E E T
device will accept additional sector erase commands.
mand. If DQ3 is high on the second status check, the
last command might not have been accepted.
To ensure the command has been accepted, the
system software should check the status of DQ3 prior
to and following each subsequent sector erase com-
Table 23 shows the status of DQ3 relative to the other
status bits.
Table 23. Write Operation Status
DQ7
(Note 2)
DQ5
(Note 1)
DQ2
(Note 2)
RDY (Note
5)
Status
DQ6
DQ3
N/A
1
Embedded Program Algorithm
Embedded Erase Algorithm
Erase
DQ7#
0
Toggle
Toggle
0
0
No toggle
Toggle
0
0
Standard
Mode
High
Impedance
1
No toggle
0
N/A
Toggle
Suspended Sector
Erase-Suspend-
Read (Note 4)
Erase
Suspend
Mode
Non-Erase
High
Impedance
Data
Data
Data
0
Data
N/A
Data
N/A
Suspended Sector
Erase-Suspend-Program
DQ7#
Toggle
0
Notes:
1. DQ5 switches to ‘1’ when an Embedded Program or Embedded Erase operation has exceeded the maximum timing limits.
Refer to the section on DQ5 for more information.
2. DQ7 and DQ2 require a valid address when reading status information. Refer to the appropriate subsection for further details.
3. When reading write operation status bits, the system must always provide the bank address where the Embedded Algorithm
is in progress. The device outputs array data if the system addresses a non-busy bank.
4. The system may read either asynchronously or synchronously (burst) while in erase suspend.
5. The RDY pin acts a dedicated output to indicate the status of an embedded erase or program operation is in progress. This
is available in the Asynchronous mode only.
52
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
ABSOLUTE MAXIMUM RATINGS
Storage Temperature
Plastic Packages . . . . . . . . . . . . . . . –65°C to +150°C
20 ns
20 ns
Ambient Temperature
with Power Applied. . . . . . . . . . . . . . –65°C to +125°C
+0.8 V
Voltage with Respect to Ground:
All Inputs and I/Os except
as noted below (Note 1). . . . . . . –0.5 V to V + 0.5 V
–0.5 V
–2.0 V
IO
V
V
(Note 1). . . . . . . . . . . . . . . . . .–0.5 V to +2.5 V
. . . . . . . . . . . . . . . . . . . . . . . . .–0.5 V to +2.5 V
CC
IO
20 ns
A9, RESET#, ACC (Note 1) . . . . .–0.5 V to +12.5 V
Output Short Circuit Current (Note 3) . . . . . . 100 mA
Notes:
Figure 10. Maximum Negative
Overshoot Waveform
1. Minimum DC voltage on input or I/Os is –0.5 V. During
voltage transitions, inputs or I/Os may undershoot VSS to
–2.0 V for periods of up to 20 ns. See Figure 10.
Maximum DC voltage on input or I/Os is VCC + 0.5 V.
During voltage transitions outputs may overshoot to VCC
+ 2.0 V for periods up to 20 ns. See Figure 11.
20 ns
VCC
2. No more than one output may be shorted to ground at a
time. Duration of the short circuit should not be greater
than one second.
+2.0 V
VCC
+0.5 V
3. Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only; functional operation of the de-
vice at these or any other conditions above those indicated
in the operational sections of this data sheet is not implied.
Exposure of the device to absolute maximum rating condi-
tions for extended periods may affect device reliability.
1.0 V
20 ns
20 ns
Figure 11. Maximum Positive
Overshoot Waveform
OPERATING RANGES
Industrial (I) Devices
Ambient Temperature (T ) . . . . . . . . . –40°C to +85°C
A
Supply Voltages
V
Supply Voltages . . . . . . . . . . .+1.65 V to +1.95 V
CC
. . . . . . . . . . . . . . . . . . . . . . . . . . . VCC ≥ V –100 mV
IO
V
Supply Voltages. . . . . . . . . . . +1.65 V to +1.95 V
IO
Operating ranges define those limits between which the func-
tionality of the device is guaranteed.
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
53
D A T A S H E E T
DC CHARACTERISTICS
CMOS COMPATIBLE
Parameter Description
Test Conditions Note: 1 & 2
Min
Typ
Max
1
Unit
µA
ILI
Input Load Current
VIN = VSS to VCC, VCC = VCCmax
VOUT = VSS to VCC, VCC = VCCmax
ILO
Output Leakage Current
1
µA
CE# = VIL, OE# = VIH,
WE# = VIH, burst length 54 MHz
= 8
9
8
7
17
15.5
14
mA
mA
mA
CE# = VIL, OE# = VIH,
WE# = VIH, burst length 54 MHz
= 16
ICCB
VCC Active burst Read Current
CE# = VIL, OE# = VIH,
WE# = VIH, burst length 54 MHz
= Continuous
IIO1
VIO Non-active Output
OE# = VIH
1
40
30
15
5
µA
mA
mA
mA
mA
µA
10 MHz
20
10
3.5
15
0.2
1
VCC Active Asynchronous Read
Current (Note 3)
CE# = VIL, OE# = VIH,
WE# = VIH
ICC1
5 MHz
1 MHz
CE# = VIL, OE# = VIH, ACC = VIH
CE# = RESET# = VCC 0.2 V
RESET# = VIL, CLK = VIL
ICC2
ICC3
ICC4
VCC Active Write Current (Note 4)
VCC Standby Current (Note 5)
VCC Reset Current
40
40
40
µA
VCC Active Current
(Read While Write)
ICC5
ICC6
CE# = VIL, OE# = VIH
CE# = VIL, OE# = VIH
25
60
mA
VCC Sleep Current
1
7
5
40
15
µA
mA
mA
V
VACC
Accelerated Program Current
(Note 6)
CE# = VIL, OE# = VIH,
VACC = 12.0 0.5 V
IACC
VCC
10
VIL
VIH
Input Low Voltage
Input High Voltage
Output Low Voltage
Output High Voltage
VIO = 1.8 V
–0.4
0.4
VIO = 1.8 V
VIO – 0.4
VIO + 0.4
0.1
V
VOL
VOH
IOL = 100 µA, VIO = VCC = VCC min
V
IOH = –100 µA, VIO = VCC = VCC min VIO – 0.1
V
Voltage for Autoselect and
Temporary Sector Unprotect
VID
VCC = 1.8 V
11.5
12.5
V
VHH
Voltage for Accelerated Program
Low VCC Lock-out Voltage
11.5
1.0
12.5
1.4
V
V
VLKO
Note:
1. Maximum ICC specifications are tested with VCC = VCCmax.
2. VIO= VCC
3. The ICC current listed is typically less than 2 mA/MHz, with OE# at VIH.
4. ICC active while Embedded Erase or Embedded Program is in progress.
5. Device enters automatic sleep mode when addresses are stable for tACC + 60 ns. Typical sleep mode current is equal to ICC3
6. Total current during accelerated programming is the sum of VACC and VCC currents.
.
54
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
TEST CONDITIONS
Table 24. Test Specifications
Test Condition All Speed Options Unit
Output Load Capacitance, CL
(including jig capacitance)
30
pF
Device
Under
Test
Input Rise and Fall Times
Input Pulse Levels
3
ns
V
0.0–VIO
C
L
Input timing measurement
reference levels
VIO/2
V
V
Output timing measurement
reference levels
VIO/2
Figure 12. Test Setup
KEY TO SWITCHING WAVEFORMS
WAVEFORM
INPUTS
OUTPUTS
Steady
Changing from H to L
Changing from L to H
Don’t Care, Any Change Permitted
Does Not Apply
Changing, State Unknown
Center Line is High Impedance State (High Z)
SWITCHING WAVEFORMS
VIO
All Inputs and Outputs
VIO/2
VIO/2
Input
Measurement Level
Output
0.0 V
Figure 13. Input Waveforms and Measurement Levels
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
55
D A T A S H E E T
AC CHARACTERISTICS
Power-up
V
CC
Parameter
tVCS
Description
VCC Setup Time
Test Setup
Speed
50
Unit
µs
Min
Min
Min
tVIOS
VIO Setup Time
50
µs
tRSTH
RESET# Low Hold Time
50
µs
tVCS
VCC
f
tVIOS
VIOf
tRSTH
RESET#
Figure 14.
V
Power-up Diagram
CC
Notes:
1.
V
≥ V –100 mV and V ramp rate exceeds 1 V/100 µs.
IO CC
CC
2. If the V ramp rate is less than 1 V /100 µs, a hardware reset will be required.
CC
CLK Characterization
Parameter
fCLK
tCLK
tCH
Description
CLK Frequency
66 MHz
66
54 MHz
54
Unit
Max
Min
MHz
ns
CLK Period
CLK High Time
CLK Low Time
CLK Rise Time
CLK Fall Time
15
18.5
Min
6.0
3
7.4
3
ns
ns
tCL
tCR
Max
tCF
t
CLK
t
t
CL
CH
CLK
t
t
CF
CR
Figure 15. CLK Characterization
Am29BDS128H/Am29BDS640H
56
27024B3 May 10, 2006
D A T A S H E E T
AC CHARACTERISTICS
Synchronous/Burst Read
Parameter
Description
66 MHz
54 MHz
Unit
JEDEC
Standard
Latency (Even address in Reduced wait-state
Handshaking mode)
tIACC
Max
Max
Max
56
69
ns
Latency (Standard Handshaking or Odd
address in Reduced wait-state Handshaking
mode
tIACC
71
11
87.5
13.5
ns
ns
Burst Access Time Valid Clock to Output
Delay
tBACC
tACS
tACH
tBDH
tCR
Address Setup Time to CLK (Note )
Address Hold Time from CLK (Note )
Data Hold Time from Next Clock Cycle
Chip Enable to RDY Valid
Output Enable to Output Valid
Chip Enable to High Z
Min
Min
Min
Max
Max
Max
Max
Min
Min
Max
Min
Min
Min
Min
Min
Max
Max
Max
Min
Max
4
6
5
7
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ms
3
4
11
11
8
13.5
13.5
10
10
5
tOE
tCEZ
tOEZ
tCES
tRDYS
tRACC
tAAS
tAAH
tCAS
tAVC
tAVD
tACC
tCKA
tCKZ
tOES
tRCC
Output Enable to High Z
CE# Setup Time to CLK
8
4
RDY Setup Time to CLK
Ready Access Time from CLK
Address Setup Time to AVD# (Note )
Address Hold Time to AVD# (Note )
CE# Setup Time to AVD#
AVD# Low to CLK
4
5
11
4
13.5
5
6
7
0
4
5
12
55
13.5
10
5
AVD# Pulse
10
50
11
8
Access Time
CLK to access resume
CLK to High Z
Output Enable Setup Time
Read cycle for continuous suspend
4
1
Note: Addresses are latched on the first of either the active edge of CLK or the rising edge of AVD#.
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
57
D A T A S H E E T
AC CHARACTERISTICS
tCEZ
tCES
7 cycles for initial access shown.
CE#f
1
2
3
4
5
6
7
CLK
tAVC
AVD#
tAVD
tACS
tBDH
Addresses
Data
Aa
tBACC
tACH
Hi-Z
tIACC
tACC
Da
Da + 1
Da + n
tOEZ
OE#
RDY
tCR
tRACC
tOE
Hi-Z
Hi-Z
tRDYS
Notes:
1. Figure shows total number of wait states set to seven cycles. The total number of wait states can be programmed from two
cycles to seven cycles.
2. If any burst address occurs at a 64-word boundary, two additional clock cycle are inserted, and is indicated by RDY.
3. The device is in synchronous mode.
Figure 16. CLK Synchronous Burst Mode Read (rising active CLK)
tCEZ
4 cycles for initial access shown.
tCES
CE#
1
2
3
4
5
CLK
tAVC
AVD#
tAVD
tACS
tBDH
Aa
Addresses
Data
tBACC
tACH
Hi-Z
tIACC
Da
Da + 1
Da + n
tACC
tOEZ
OE#
RDY
tRACC
tOE
tCR
Hi-Z
Hi-Z
tRDYS
Notes:
1. Figure shows total number of wait states set to four cycles. The total number of wait states can be programmed from two
cycles to seven cycles. Clock is set for active falling edge.
2. If any burst address occurs at a 64-word boundary, two additional clock cycle are inserted, and is indicated by RDY.
3. The device is in synchronous mode.
Figure 17. CLK Synchronous Burst Mode Read (Falling Active Clock)
58
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
AC CHARACTERISTICS
tCEZ
7 cycles for initial access shown.
tCAS
CE#
1
2
3
4
5
6
7
CLK
tAVC
AVD#
tAVD
tAAS
tBDH
Addresses
Data
Aa
tBACC
tAAH
Hi-Z
tIACC
Da
Da + 1
Da + n
tACC
tOEZ
OE#
RDY
tRACC
tCR
tOE
Hi-Z
Hi-Z
tRDYS
Notes:
1. Figure shows total number of wait states set to seven cycles. The total number of wait states can be programmed from two
cycles to seven cycles. Clock is set for active rising edge.
2. If any burst address occurs at a 64-word boundary, two additional clock cycle are inserted, and is indicated by RDY.
3. The device is in synchronous mode.
Figure 18. Synchronous Burst Mode Read
7
cycles for initial access shown.
tCES
CE#
CLK
1
2
3
4
5
6
7
tAVC
AVD#
tAVD
tACS
tBDH
A6
Addresses
Data
tBACC
tACH
tIACC
tACC
D6
D7
D0
D1
D5
D6
OE#
RDY
tCR
tRACC
tOE
Hi-Z
tRDYS
Note: Figure assumes 7 wait states for initial access and automatic detect synchronous read. D0–D7 in data waveform indicate
the order of data within a given 8-word address range, from lowest to highest. Starting address in figure is the 7th address in
range (A6). See “Requirements for Synchronous (Burst) Read Operation”. The Set Configuration Register command sequence
has been written with A18=1; device will output RDY with valid data.
Figure 19. 8-word Linear Burst with Wrap Around
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
59
D A T A S H E E T
AC CHARACTERISTICS
tCEZ
6
wait cycles for initial access shown.
tCES
CE#
1
2
3
4
5
6
CLK
tAVC
AVD#
tAVD
tACS
tBDH
Aa
Addresses
tBACC
tACH
Hi-Z
Data
tIACC
Da
Da+1
Da+2
Da+3
Da + n
tACC
tOEZ
tRACC
OE#
tCR
tOE
Hi-Z
Hi-Z
RDY
tRDYS
Note: Figure assumes 6 wait states for initial access and synchronous read. The Set Configuration Register command sequence
has been written with A18=0; device will output RDY one cycle before valid data.
Figure 20. Linear Burst with RDY Set One Cycle Before Data
60
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
AC CHARACTERISTICS
Suspend
Resume
x
x+2
x+3
x+4
x+6
x+7
x+8
x+1
x+5
CLK
AVD#
t
t
OES
OES
Addresses
t
CKA
t
CKZ
OE#
Data
D(24)
D(20)
D(23)
D(23)
D(23)
D(22)
D(20)
D(21)
RDY
t
RACC
t
RACC
Note: Figure is for any even address other than 3Eh (or multiple thereof).
Figure 21. Reduced Wait-state Handshake Burst Suspend/Resume at an Even Address
Suspend
Resume
x+1
x
x+2
x+3
x+4
x+6
x+7
x+8
x+5
CLK
AVD#
t
t
OES
OES
Addresses
t
CKA
t
CKZ
OE#
Data
D(27)
D(23)
D(25)
D(25)
D(26)
D(25)
D(23)
D(24)
RDY
t
RACC
t
RACC
Note: Figure is for any odd address other than 3Fh (or multiple thereof).
Figure 22. Reduced Wait-state Handshake Burst Suspend/Resume at an Odd Address
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
61
D A T A S H E E T
AC CHARACTERISTICS
Resume
Suspend
x+1
x+2
x+3
x+4
x+5
x+7
x+8
x+9
x
x+6
x+10
CLK
AVD#
t
OES
t
OES
Addresses
OE#
t
CKA
t
CKZ
D(42)
D(41)
D(3E)
D(41)
D(3E)
D(3F)
D(40)
D(3F)
D(41)
D(3F)
Data
RDY
t
t
RACC
RACC
Figure 23. Reduced Wait-state Handshake Burst Suspend/Resume at Address 3Eh (or Offset from 3Eh)
Resume
x+1
Suspend
x+2
x+3
x+4
x+5
x+7
x+8
x+9
x
x+6
x+10
CLK
AVD#
t
OES
t
OES
Addresses
OE#
t
CKA
t
CKZ
D(43)
D(42)
D(3F)
RACC
D(41)
D(3F)
D(3F)
D(41)
D(40)
D(41)
D(3F)
Data
RDY
t
t
RACC
t
RACC
Figure 24. Reduced Wait-state Handshake Burst Suspend/Resume at Address 3Fh (or Offset from 3Fh by
a Multiple of 64)
62
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
AC CHARACTERISTICS
Resume
Suspend
x
x+2
x+3
x+4
x+6
x+7
x+8
1
2
6
5
x+1
3
4
7
x+5
CLK
AVD#
t
t
OES
OES
A(n)
Addresses
t
CKA
OE#
Data(1)
D(n)
D(n+2)
D(n+1)
3F
D(3F)
3F
D(40)
t
ACC
RDY(1)
t
RACC
D(n+2) D(n+3) D(n+4) D(n+5)
Data(2)
RDY(2)
D(n+1)
D(n)
D(n+6)
t
RACC
Note: Figure assumes 6 wait states for initial access and synchronous read. The Set Configuration Register command sequence
has been written with A18=0; device will output RDY with valid data.
1) RDY goes low during the two-cycle latency during a boundary crossing.
2) RDY stays high when a burst sequence crosses no boundaries.
Figure 25. Standard Handshake Burst Suspend Prior to Initial Access
Resume
Suspend
x
1
6
9
x+2
5
x+1
2
3
4
7
8
x+3
CLK
AVD#
tOES
tOES
tOES
Addresses
OE#(1)
A(n)
tCKA
tCKA
tCKZ
D(n)
D(n)
D(n+1)
Data(1)
RDY(1)
tACC
tRACC
tRACC
tRACC
OE#(2)
Data(2)
D(n+2)
D(n+1)
D(n)
D(n+1)
tRACC
tRACC
tRACC
RDY(2)
Note: Figure assumes 6 wait states for initial access and synchronous read. The Set Configuration Register command sequence
has been written with A18=0; device will output RDY with valid data.
1) Burst suspend during the initial synchronous access
2) Burst suspend after one clock cycle following the initial synchronous access
Figure 26. Standard Handshake Burst Suspend at or after Initial Access
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
63
D A T A S H E E T
AC CHARACTERISTICS
Resume
x+1
Suspend
x
x+2
x+5
x+4
x+3
1
2
6
9
5
3
4
7
8
CLK
AVD#
tOES
tOES
tOES
A(3D)
Addresses
tCKA
tCKA
OE#
Data
tCKZ
D(3F)
D(3F)
D(3F) D(4D)
D(3D)
D(3E)
D(3F)
tACC
tRACC
tRACC
tRACC
RDY
Note: Figure assumes 6 wait states for initial access and synchronous read. The Set Configuration Register command sequence
has been written with A18=0; device will output RDY with valid data.
Figure 27. Standard Handshake Burst Suspend at Address 3Fh (Starting Address 3Dh or Earlier)
Resume
Suspend
5
x
1
2
3
6
7
x+1
x+2
x+3
4
x+4
x+5
x+6
8
CLK
AVD#
tOES
tOES
A(3E)
Addresses(1)
tOES
tCKA
OE#
tCKZ
D(40)
D(3F)
D(41)
D(42)
D(3E)
D(3E)
Data(1)
RDY(1)
tACC
tRACC
tRACC
tRACC
Addresses(2)
A(3F)
Data(2)
RDY(2)
D(41)
D(3F)
tRACC
D(40)
D(42)
D(43)
D(3F)
t
tRACC
RACC
Note: Figure assumes 6 wait states for initial access and synchronous read. The Set Configuration Register command sequence
has been written with A18=0; device will output RDY with valid data.
1) Address is 3Eh or offset by a multiple of 64 (40h).
2) Address is 3Fh or offset by a multiple of 64 (40h).
Figure 28. Standard Handshake Burst Suspend at Address 3Eh/3Fh (Without a Valid Initial Access)
64
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
AC CHARACTERISTICS
Suspend
8
Resume
x+1
5
1
2
3
6
7
4
9
x
x+2
x+3
x+4
x+5
x+6
CLK
AVD#
t
t
OES
OES
A(3E)
Addresses(1)
OE#
tOES
t
CKA
t
CKZ
D(40)
Data(1)
D(3F)
D(3F)
RACC
D(41)
D(42)
D(3E)
t
ACC
RDY(1)
(Even)
t
RACC
t
RACC
t
Addresses(2)
Data(2)
A(3F)
D(3F)
D(41)
D(42)
D(40)
D(43)
D(40)
RACC
RDY(2)
(Odd)
t
t
RACC
RACC
t
Note: Figure assumes 6 wait states for initial access and synchronous read. The Set Configuration Register command sequence
has been written with A18=0; device will output RDY with valid data.
1) Address is 3Eh or offset by a multiple of 64 (40h)
2) Address is 3Fh or offset by a multiple of 64 (40h)
Figure 29. Standard Handshake Burst Suspend at Address 3Eh/3Fh (with 1 Access CLK)
Resume
x+1
Suspend
x
x+2
x+3
x+4
x+6
x+7
x+8
1
6
5
2
3
4
7
x+5
CLK
t
RCC
AVD#
t
t
OES
OES
A(n)
Addresses
OE#
t
CKA
Data(1)
RDY
D(n)
D(n+2)
D(n+1)
D(3F) D(3F)
D(3F)
D(40)
t
ACC
t
RACC
D(n)
???
???
Data(2)
CE#
t
RCC
Note: Figure assumes 6 wait states for initial access and synchronous read. The Set Configuration Register command sequence
has been written with A18=0; device will output RDY with valid data.
1) Device crosses a page boundary prior to tRCC
.
2) Device neither crosses a page boundary nor latches a new address prior to tRCC
.
Figure 30. Read Cycle for Continuous Suspend
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
65
D A T A S H E E T
AC CHARACTERISTICS
Asynchronous Mode Read
Parameter
JEDEC Standard Description
75 MHz
45
66 MHz
50
54 MHz
Unit
ns
tCE
tACC
tAVDP
Access Time from CE# Low
Asynchronous Access Time (Note 1)
AVD# Low Time
Max
55
55
12
5
Max
Min
Min
45
50
ns
10
4
ns
tAAVDS Address Setup Time to Rising Edge of AVD
ns
tAAVDH Address Hold Time from Rising Edge of AVD Min
5.5
8.5
6
11
0
7
ns
tOE
Output Enable to Output Valid
Max
Min
13.5
ns
Read
ns
Output Enable Hold
tOEH
Toggle and
Data# Polling
Time
Min
8
8
10
10
ns
tOEZ
tCAS
Output Enable to High Z (Note 2)
CE# Setup Time to AVD#
Max
Min
ns
ns
0
Notes:
1. Asynchronous Access Time is from the last of either stable addresses or the falling edge of AVD#.
2. Not 100% tested.
66
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
AC CHARACTERISTICS
CE#
tOE
OE#
tOEH
WE#
Data
tCE
tOEZ
Valid RD
tACC
RA
Addresses
AVD#
tAAVDH
tCAS
tAVDP
tAAVDS
Note: RA = Read Address, RD = Read Data.
Figure 31. Asynchronous Mode Read with Latched Addresses
CE#
OE#
tOE
tOEH
WE#
Data
tCE
tOEZ
Valid RD
tACC
RA
Addresses
AVD#
Note: RA = Read Address, RD = Read Data.
Figure 32. Asynchronous Mode Read
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
67
D A T A S H E E T
AC CHARACTERISTICS
Hardware Reset (RESET#)
Parameter
All Speed
Options
JEDEC
Std
Description
Unit
RESET# Pin Low (During Embedded Algorithms)
to Read Mode (See Note)
tReadyw
Max
Max
20
μs
RESET# Pin Low (NOT During Embedded Algorithms)
to Read Mode (See Note)
tReady
500
ns
tRP
tRH
RESET# Pulse Width
Min
Min
Min
500
200
20
ns
ns
μs
Reset High Time Before Read (See Note)
RESET# Low to Standby Mode
tRPD
Note: Not 100% tested.
CE#, OE#
RESET#
tRH
tRP
tReady
Reset Timings NOT during Embedded Algorithms
Reset Timings during Embedded Algorithms
CE#, OE#
RESET#
tReadyw
tRP
Figure 33. Reset Timings
68
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
AC CHARACTERISTICS
Erase/Program Operations
Parameter
JEDEC Standard Description
75 MHz
66 MHz
54 MHz
Unit
tAVAV
tWC
Write Cycle Time (Note 1)
Min
Min
45
50
55
5
ns
Address Setup
Time (Notes 2,
3)
Synchronous
Asynchronous
4
tAVWL
tAS
ns
ns
0
6
Address Hold
Time (Notes 2,
3)
Synchronous
Asynchronous
5.5
15
7
tWLAX
tAH
Min
20
20
tAVDP
tDS
AVD# Low Time
Data Setup Time
Data Hold Time
Min
Min
Min
Min
Min
Min
Min
Min
10
20
12
45
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
tDVWH
tWHDX
tGHWL
tDH
0
0
0
0
tGHWL
tCAS
tCH
Read Recovery Time Before Write
CE# Setup Time to AVD#
CE# Hold Time
tWHEH
tWLWH
tWHWL
tWP
Write Pulse Width
20
30
20
tWPH
tSR/W
tVID
Write Pulse Width High
15
20
0
Latency Between Read and Write Operations Min
VACC Rise and Fall Time
Min
Min
500
VACC Setup Time (During Accelerated
Programming)
tVIDS
1
µs
tVCS
tCS
VCC Setup Time
Min
Min
Min
Min
Min
Min
Min
Min
Max
Max
Typ
50
0
µs
ns
ns
ns
ns
ns
ns
ns
µs
µs
µs
tELWL
CE# Setup Time to WE#
tAVSW
tAVHW
tACS
tACH
tAVHC
tCSW
tSEA
AVD# Setup Time to WE#
AVD# Hold Time to WE#
4
4
4
5
5
5
7
5
Address Setup Time to CLK (Notes 2, 3)
Address Hold Time to CLK (Notes 2, 3)
AVD# Hold Time to CLK
5.5
6
4
Clock Setup Time to WE#
Sector Erase Accept Timeout
Erase Suspend Latency
5
50
tESL
35
tASP
Toggle Time During Sector Protection
100
Toggle Time During Programming within a
Protected Sector
tPSP
Typ
1
µs
Notes:
1. Not 100% tested.
program operation timing, addresses are latched on the first of either
the falling edge of WE# or the active edge of CLK.
2. Asynchronous mode allows both Asynchronous and Synchronous
program operation. Synchronous mode allows both Asynchronous
and Synchronous program operation.
4. See the “Erase and Programming Performance” section for more
information.
3. In asynchronous program operation timing, addresses are latched
on the falling edge of WE# or rising edge of AVD#. In synchronous
5. Does not include the preprogramming time.
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
69
D A T A S H E E T
AC CHARACTERISTICS
Program Command Sequence (last two cycles)
Read Status Data
V
IH
CLK
V
IL
tAVDP
AVD#
tAH
tAS
PA
VA
VA
Addresses
Data
555h
In
Complete
A0h
PD
tDS
tDH
Progress
CE#f
tCH
OE#
WE#
tWP
tWHWH1
tCS
tWPH
tWC
tVCS
VCC
f
Notes:
1. PA = Program Address, PD = Program Data, VA = Valid Address for reading status bits.
2. “In progress” and “complete” refer to status of program operation.
3. Amax–A12 are don’t care during command sequence unlock cycles.
4. CLK can be either VIL or VIH.
5. The Asynchronous programming operation is independent of the Set Device Read Mode bit in the Configuration Register.
Figure 34. Asynchronous Program Operation Timings: AVD# Latched Addresses
70
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
AC CHARACTERISTICS
Program Command Sequence (last two cycles)
Read Status Data
V
IH
CLK
V
IL
tAVSW
tAVHW
AVD#
tAVDP
tAS
tAH
Addresses
Data
555h
VA
VA
PA
In
A0h
Complete
PD
Progress
tDS
tDH
CE#f
tCH
OE#
WE#
tWP
tWHWH1
tCS
tWPH
tWC
tVCS
V
CCf
Notes:
1. PA = Program Address, PD = Program Data, VA = Valid Address for reading status bits.
2. “In progress” and “complete” refer to status of program operation.
3. Amax–A12 are don’t care during command sequence unlock cycles.
4. CLK can be either VIL or VIH.
5. The Asynchronous programming operation is independent of the Set Device Read Mode bit in the Configuration Register.
Figure 35. Asynchronous Program Operation Timings: WE# Latched Addresses
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
71
D A T A S H E E T
AC CHARACTERISTICS
Program Command Sequence (last two cycles)
tAVCH
Read Status Data
CLK
tACS
tACH
AVD#
tAVDP
Addresses
555h
PA
VA
VA
In
Data
Complete
A0h
PD
tDS
tDH
Progress
tCAS
CE#f
OE#
tCH
tCSW
tWP
WE#
tWHWH1
tWPH
tWC
tVCS
VCC
f
Notes:
1. PA = Program Address, PD = Program Data, VA = Valid Address for reading status bits.
2. “In progress” and “complete” refer to status of program operation.
3. Amax–A12 are don’t care during command sequence unlock cycles.
4. Addresses are latched on the first of either the rising edge of AVD# or the active edge of CLK.
5. Either CE# or AVD# is required to go from low to high in between programming command sequences.
6. The Synchronous programming operation is dependent of the Set Device Read Mode bit in the Configuration Register. The
Configuration Register must be set to the Synchronous Read Mode.
Figure 36. Synchronous Program Operation Timings: WE# Latched Addresses
72
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
AC CHARACTERISTICS
Program Command Sequence (last two cycles)
tAVCH
Read Status Data
CLK
tAS
tAH
AVD#
tAVDP
Addresses
555h
PA
VA
VA
In
Data
Complete
A0h
PD
tDS
tDH
Progress
tCAS
CE#f
tCH
OE#
WE#
tCSW
tWP
tWHWH1
tWPH
tWC
tVCS
VCC
f
Notes:
1. PA = Program Address, PD = Program Data, VA = Valid Address for reading status bits.
2. “In progress” and “complete” refer to status of program operation.
3. Amax–A12 are don’t care during command sequence unlock cycles.
4. Addresses are latched on the first of either the rising edge of AVD# or the active edge of CLK.
5. Either CE# or AVD# is required to go from low to high in between programming command sequences.
6. The Synchronous programming operation is dependent of the Set Device Read Mode bit in the Configuration Register. The
Configuration Register must be set to the Synchronous Read Mode.
Figure 37. Synchronous Program Operation Timings: CLK Latched Addresses
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
73
D A T A S H E E T
AC CHARACTERISTICS
Erase Command Sequence (last two cycles)
Read Status Data
V
IH
CLK
V
IL
tAVDP
AVD#
tAH
tAS
SA
555h for
chip erase
VA
VA
Addresses
Data
2AAh
10h for
chip erase
In
Complete
55h
30h
Progress
tDS
tDH
CE#
tCH
OE#
WE#
tWP
tWHWH2
tCS
tWPH
tWC
tVCS
VCC
Figure 38. Chip/Sector Erase Command Sequence
Notes:
1. SA is the sector address for Sector Erase.
2. Address bits Amax–A12 are don’t cares during unlock cycles in the command sequence.
74
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
AC CHARACTERISTICS
CE#
AVD#
WE#
Addresses
Data
PA
Don't Care
Don't Care
A0h
PD
Don't Care
OE#
tVIDS
1 μs
V
ID
ACC
tVID
V
or V
IH
IL
Note: Use setup and hold times from conventional program operation.
Figure 39. Accelerated Programming Timing
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
75
D A T A S H E E T
AC CHARACTERISTICS
AVD#
tCEZ
tCE
CE#
tOEZ
tCH
tOE
OE#
tOEH
WE#
tACC
VA
Addresses
Data
VA
Status Data
Status Data
Notes:
1. Status reads in figure are shown as asynchronous.
2. VA = Valid Address. Two read cycles are required to determine status. When the Embedded Algorithm operation is complete,
and Data# Polling will output true data.
3. While in Asynchronous mode, RDY will be low while the device is in embedded erase or programming mode.
Figure 40. Data# Polling Timings (During Embedded Algorithm)
AVD#
tCEZ
tCE
CE#
tOEZ
tCH
tOE
OE#
WE#
tOEH
tACC
Addresses
Data
VA
VA
Status Data
Status Data
Notes:
1. Status reads in figure are shown as asynchronous.
2. VA = Valid Address. Two read cycles are required to determine status. When the Embedded Algorithm operation is complete,
the toggle bits will stop toggling.
3. While in Asynchronous mode, RDY will be low while the device is in embedded erase or programming mode.
Figure 41. Toggle Bit Timings (During Embedded Algorithm)
76
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
AC CHARACTERISTICS
CE#
CLK
AVD#
Addresses
OE#
VA
VA
tIACC
tIACC
Data
Status Data
Status Data
RDY
Notes:
1. The timings are similar to synchronous read timings.
2. VA = Valid Address. Two read cycles are required to determine status. When the Embedded Algorithm operation is complete, the
toggle bits will stop toggling.
3. RDY is active with data (A18 = 0 in the Configuration Register). When A18 = 1 in the Configuration Register, RDY is active one
clock cycle before data.
Figure 42. Synchronous Data Polling Timings/Toggle Bit Timings
Enter
Embedded
Erasing
Erase
Suspend
Enter Erase
Suspend Program
Erase
Resume
Erase
Erase Suspend
Read
Erase
Suspend
Program
Erase
Complete
WE#
Erase
Erase Suspend
Read
DQ6
DQ2
Note: DQ2 toggles only when read at an address within an erase-suspended sector. The system may use OE# or CE# to toggle
DQ2 and DQ6.
Figure 43. DQ2 vs. DQ6
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
77
D A T A S H E E T
AC CHARACTERISTICS
Temporary Sector Unprotect
Parameter
JEDEC
Std
tVIDR
tVHH
Description
All Speed Options
Unit
ns
VID Rise and Fall Time (See Note)
VHH Rise and Fall Time (See Note)
Min
Min
500
250
ns
RESET# Setup Time for Temporary Sector
Unprotect
tRSP
Min
Min
4
4
µs
µs
RESET# Hold Time from RDY High for
Temporary Sector Unprotect
tRRB
Note: Not 100% tested.
VID
VID
RESET#
VIL or VIH
VIL or VIH
tVIDR
tVIDR
Program or Erase Command Sequence
CE#
WE#
RDY
tRRB
tRSP
Figure 44. Temporary Sector Unprotect Timing Diagram
78
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
AC CHARACTERISTICS
V
ID
IH
V
RESET#
SA, A6,
A1, A0
Valid*
Sector Protect/Unprotect
60h 60h
Valid*
Valid*
Status
Verify
40h
Data
Sector Protect: 150 µs
Sector Unprotect: 15 ms
1 µs
CE#
WE#
OE#
* For sector protect, A6 = 0, A1 = 1, A0 = 0. For sector unprotect, A6 = 1, A1 = 1, A0 = 0.
Figure 45. Sector/Sector Block Protect and
Unprotect Timing Diagram
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
79
D A T A S H E E T
AC CHARACTERISTICS)
Address boundary occurs every 64 words, beginning at address
00003Fh: 00007Fh, 0000BFh, etc.) Address 000000h is also a boundary crossing.
C60
C61
3D
C62
3E
C63
3F
C63
3F
C63
3F
C64
40
C65
41
C66
42
C67
43
CLK
3C
Address (hex)
(stays high)
AVD#
RDY(1)
RDY(2)
tRACC
tRACC
latency
tRACC
tRACC
latency
Data
D60
D61
D62
D63
D64
D65
D66
D67
Notes:
1. RDY active with data (A18 = 0 in the Configuration Register).
2. RDY active one clock cycle before data (A18 = 1 in the Configuration Register).
3. Cxx indicates the clock that triggers Dxx on the outputs; for example, C60 triggers D60. Figure shows the device not crossing
a bank in the process of performing an erase or program.
4. If the starting address latched in is either 3Eh or 3Fh (or some 64 multiple of either), there is no additional 2 cycle latency at
the boundary crossing.
Figure 46. Latency with Boundary Crossing
80
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
AC CHARACTERISTICS
Address boundary occurs every 64 words, beginning at address
00003Fh: (00007Fh, 0000BFh, etc.) Address 000000h is also a boundary crossing.
C60
C61
3D
C62
3E
C63
3F
C63
3F
C63
3F
C64
40
CLK
3C
Address (hex)
(stays high)
AVD#
RDY(1)
RDY(2)
tRACC
tRACC
latency
tRACC
tRACC
latency
Data
Invalid
D60
D61
D62
D63
Read Status
OE#,
CE#
(stays low)
Notes:
1. RDY active with data (A18 = 0 in the Configuration Register).
2. RDY active one clock cycle before data (A18 = 1 in the Configuration Register).
3. Cxx indicates the clock that triggers Dxx on the outputs; for example, C60 triggers D60. Figure shows the device crossing a
bank in the process of performing an erase or program.
Figure 47. Latency with Boundary Crossing
into Program/Erase Bank
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
81
D A T A S H E E T
AC CHARACTERISTICS
Data
D0
D1
Rising edge of next clock cycle
following last wait state triggers
next burst data
AVD#
OE#
total number of clock cycles
following AVD# falling edge
1
2
0
3
1
4
5
6
4
7
5
CLK
2
3
number of clock cycles
programmed
Wait State Decoding Addresses:
A14, A13, A12 = “111” ⇒ Reserved
A14, A13, A12 = “110” ⇒ Reserved
A14, A13, A12 = “101” ⇒ 5 programmed, 7 total
A14, A13, A12 = “100” ⇒ 4 programmed, 6 total
A14, A13, A12 = “011” ⇒ 3 programmed, 5 total
A14, A13, A12 = “010” ⇒ 2 programmed, 4 total
A14, A13, A12 = “001” ⇒ 1 programmed, 3 total
A14, A13, A12 = “000” ⇒ 0 programmed, 2 total
Note: Figure assumes address D0 is not at an address boundary, active clock edge is rising, and wait state is set to “101”.
Figure 48. Example of Wait States Insertion
82
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
AC CHARACTERISTICS
Last Cycle in
Program or
Sector Erase
Read status (at least two cycles) in same bank
and/or array data from other bank
Begin another
write or program
command sequence
Command Sequence
tWC
tRC
tRC
tWC
CE#
OE#
tOE
tOEH
tGHWL
WE#
Data
tWPH
tOEZ
tWP
tDS
tACC
tOEH
tDH
PD/30h
RD
RD
AAh
tSR/W
RA
Addresses
AVD#
PA/SA
tAS
RA
555h
tAH
Note: Breakpoints in waveforms indicate that system may alternately read array data from the “non-busy bank” while checking
the status of the program or erase operation in the “busy” bank. The system should read status twice to ensure valid information.
Figure 49. Back-to-Back Read/Write Cycle Timings
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
83
D A T A S H E E T
ERASE AND PROGRAMMING PERFORMANCE
Parameter
Typ (Note 1) Max (Note 2)
Unit
Comments
32 Kword
4 Kword
128 Mb
64 Mb
0.4
0.2
103
54
5
5
Sector Erase Time
s
Excludes 00h programming prior to erasure
(Note 4)
s
s
Chip Erase Time
Word Programming Time
9
210
120
226.5
114
99
µs
µs
s
Accelerated Word Programming Time
4
Excludes system level overhead (Note 5)
Excludes system level overhead (Note 5)
128 Mb
75.5
38
Chip Programming Time
(Note 3)
64 Mb
s
128 Mb
33
s
Accelerated Chip
Programming Time
64 Mb
17
30
s
Notes:
1. Typical program and erase times assume the following conditions: 25°C, 1.8 V VCC, 1 million cycles. Additionally,
programming typicals assumes a checkerboard pattern.
2. Under worst case conditions of 90°C, VCC = 1.65 V, 1,000,000 cycles.
3. The typical chip programming time is considerably less than the maximum chip programming time listed.
4. In the pre-programming step of the Embedded Erase algorithm, all words are programmed to 00h before erasure.
5. System-level overhead is the time required to execute the two- or four-bus-cycle sequence for the program command. See
Table 20, “Memory Array Command Definitions,” on page 46 for further information on command definitions.
6. The device has a minimum erase and program cycle endurance of 1 million cycles.
BGA BALL CAPACITANCE
Parameter
Symbol
Parameter Description
Input Capacitance
Test Setup
VIN = 0
Typ
4.2
5.4
3.9
Max
5.0
6.5
4.7
Unit
pF
CIN
COUT
CIN2
Output Capacitance
Control Pin Capacitance
VOUT = 0
VIN = 0
pF
pF
Notes:
1. Sampled, not 100% tested.
2. Test conditions T = 25°C, f = 1.0 MHz.
A
DATA RETENTION
Parameter
Test Conditions
150°C
Min
10
Unit
Years
Years
Minimum Pattern Data Retention Time
125°C
20
84
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
PHYSICAL DIMENSIONS
VBB080—80-ball Fine-Pitch Ball Grid Array (BGA) 11.5 x 9 mm Package
D
D1
A
e
0.05
(2X)
C
8
7
6
5
4
3
2
1
e
7
SE
E1
E
M
L
K
J
H
G
F
E
D
C
B
A
A1 CORNER
INDEX MARK
10
7
B
PIN A1
CORNER
6
SD
NXφb
0.05
(2X)
C
φ 0.08
φ 0.15
M
M
C
C A
B
TOP VIEW
SIDE VIEW
BOTTOM VIEW
0.10
C
A2
A
0.08
C
C
A1
SEATING PLANE
NOTES:
PACKAGE
JEDEC
VBB 080
N/A
1. DIMENSIONING AND TOLERANCING PER ASME Y14.5M-1994.
2. ALL DIMENSIONS ARE IN MILLIMETERS.
11.50 mm x 9.00 mm NOM
PACKAGE
3. BALL POSITION DESIGNATION PER JESD 95-1, SPP-010 (EXCEPT
AS NOTED).
SYMBOL
MIN
---
NOM
---
MAX
1.00
---
NOTE
4.
e REPRESENTS THE SOLDER BALL GRID PITCH.
A
A1
A2
D
OVERALL THICKNESS
BALL HEIGHT
5. SYMBOL "MD" IS THE BALL ROW MATRIX SIZE IN THE
"D" DIRECTION.
0.20
0.62
---
SYMBOL "ME" IS THE BALL COLUMN MATRIX SIZE IN THE
"E" DIRECTION.
---
0.76
BODY THICKNESS
BODY SIZE
11.50 BSC.
9.00 BSC.
8.80 BSC.
5.60 BSC.
12
N IS THE TOTAL NUMBER OF SOLDER BALLS.
E
BODY SIZE
6
7
DIMENSION "b" IS MEASURED AT THE MAXIMUM BALL
DIAMETER IN A PLANE PARALLEL TO DATUM C.
D1
E1
MD
ME
N
BALL FOOTPRINT
BALL FOOTPRINT
SD AND SE ARE MEASURED WITH RESPECT TO DATUMS
A AND B AND DEFINE THE POSITION OF THE CENTER
SOLDER BALL IN THE OUTER ROW.
ROW MATRIX SIZE D DIRECTION
ROW MATRIX SIZE E DIRECTION
TOTAL BALL COUNT
8
WHEN THERE IS AN ODD NUMBER OF SOLDER BALLS IN
THE OUTER ROW PARALLEL TO THE D OR E DIMENSION,
RESPECTIVELY, SD OR SE = 0.000.
80
φb
0.30
0.35
0.40
BALL DIAMETER
WHEN THERE IS AN EVEN NUMBER OF SOLDER BALLS IN
THE OUTER ROW, SD OR SE = e/2
e
0.80 BSC.
0.40 BSC.
BALL PITCH
SD / SE
SOLDER BALL PLACEMENT
8. NOT USED.
(A3-A6, B3-B6, L3-L6, -M3-M6) DEPOPULATED SOLDER BALLS
9. "+" INDICATES THE THEORETICAL CENTER OF DEPOPULATED
BALLS.
10 A1 CORNER TO BE IDENTIFIED BY CHAMFER, LASER OR INK
MARK, METALLIZED MARK INDENTATION OR OTHER MEANS.
3233 \ 16-038.9h
Note: BSC is an ANSI standard for Basic Space Centering
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
85
D A T A S H E E T
PHYSICAL DIMENSIONS
VBD064—64-ball Fine-Pitch Ball Grid Array (BGA) 9 x 8 mm Package
D
D1
A
0.05
(2X)
C
8
7
6
5
7
e
SE
E
B
E1
4
3
2
1
H
G
F
E
C
B
A
D
INDEX MARK
10
PIN A1
CORNER
A1 CORNER
SD
6
NXφb
0.05
(2X)
C
φ 0.08 M C
φ 0.15 M C A B
TOP VIEW
BOTTOM VIEW
0.10
C
A2
A
0.08 C
A1
SEATING PLANE
C
SIDE VIEW
NOTES:
PACKAGE
JEDEC
VBD 064
N/A
1. DIMENSIONING AND TOLERANCING PER ASME Y14.5M-1994.
2. ALL DIMENSIONS ARE IN MILLIMETERS.
8.95 mm x 7.95 mm NOM
PACKAGE
3. BALL POSITION DESIGNATION PER JESD 95-1, SPP-010 (EXCEPT
AS NOTED).
SYMBOL
MIN
---
NOM
---
MAX
1.00
0.30
0.76
NOTE
4.
e REPRESENTS THE SOLDER BALL GRID PITCH.
A
A1
A2
D
OVERALL THICKNESS
BALL HEIGHT
5. SYMBOL "MD" IS THE BALL ROW MATRIX SIZE IN THE
"D" DIRECTION.
0.20
0.62
---
SYMBOL "ME" IS THE BALL COLUMN MATRIX SIZE IN THE
"E" DIRECTION.
---
BODY THICKNESS
BODY SIZE
8.95 BSC.
7.95 BSC.
5.60 BSC.
5.60 BSC.
8
N IS THE TOTAL NUMBER OF SOLDER BALLS.
E
BODY SIZE
6
7
DIMENSION "b" IS MEASURED AT THE MAXIMUM BALL
DIAMETER IN A PLANE PARALLEL TO DATUM C.
D1
E1
MD
ME
N
BALL FOOTPRINT
BALL FOOTPRINT
SD AND SE ARE MEASURED WITH RESPECT TO DATUMS
A AND B AND DEFINE THE POSITION OF THE CENTER
SOLDER BALL IN THE OUTER ROW.
ROW MATRIX SIZE D DIRECTION
ROW MATRIX SIZE E DIRECTION
TOTAL BALL COUNT
8
WHEN THERE IS AN ODD NUMBER OF SOLDER BALLS IN
THE OUTER ROW PARALLEL TO THE D OR E DIMENSION,
RESPECTIVELY, SD OR SE = 0.000.
64
φb
0.30
0.35
0.40
BALL DIAMETER
WHEN THERE IS AN EVEN NUMBER OF SOLDER BALLS IN
THE OUTER ROW, SD OR SE = e/2
e
0.80 BSC.
0.40 BSC.
NONE
BALL PITCH
SD / SE
SOLDER BALL PLACEMENT
DEPOPULATED SOLDER BALLS
8. NOT USED.
9. "+" INDICATES THE THEORETICAL CENTER OF DEPOPULATED
BALLS.
10 A1 CORNER TO BE IDENTIFIED BY CHAMFER, LASER OR INK
MARK, METALLIZED MARK INDENTATION OR OTHER MEANS.
3246 \ 16-038.9
Note: BSC is an ANSI standard for Basic Space Centering
86
Am29BDS128H/Am29BDS640H
27024B3 May 10, 2006
D A T A S H E E T
command. Updated PPB Program, Erase, Status com-
REVISION SUMMARY
Revision A (November 5, 2002)
Initial release.
mands to require Sector Block Address (SBA).
DC Characteristics
Updated I , I
, I
, I
, I
IO1 CC1 CC3 CC4 CC6
Revision B (February 2, 2004)
Global
Test Conditions
Updated Input Rise and Fall Times.
Power Up
Incorporated Am29BDS640H specifications from pub-
lication 27241.
V
CC
Added Ramp Rate information.
Removed 1.5 V V option. Changed 80 MHz speed
IO
grade to 75 MHz.
CLK Characterization
In-System Sector Protection/Sector Unprotection
Algorithms
Added section.
Revision B+1 (August 10, 2004)
Global
Changed “Wait 15 ms” to “Wait 1.5 ms.”
Password Protection Mode Locking Bit;
Persistent Sector Protection Mode Locking Bit
Program Command;
Incorporated Am29BDS640H specifications from pub-
lication 27241.
SecSi Sector Protection Bit Program Command;
PPB Program Command; All PPB Erase Command
Updated speed options offered.
Revision B2 (September 30, 2005)
Updated description for these sections.
Ordering Information
Command Definitions
Added package type VF (Pb-free Package (VBB080))
Revision B3 (May 10, 2006)
Changed WP to (01000010). Set Configuration Reg-
ister command is not available in Unlock Bypass Mode
Removed Password Protection Locking Bit Read
command and Persistent Protection Locking Bit Read
Added migration and obsolescence information for
Am29BDS640H. Removed Preliminary designation
from document.
Colophon
The products described in this document are designed, developed and manufactured as contemplated for general use, including without limita-
tion, ordinary industrial use, general office use, personal use, and household use, but are not designed, developed and manufactured as con-
templated (1) for any use that includes fatal risks or dangers that, unless extremely high safety is secured, could have a serious effect to the
public, and could lead directly to death, personal injury, severe physical damage or other loss (i.e., nuclear reaction control in nuclear facility,
aircraft flight control, air traffic control, mass transport control, medical life support system, missile launch control in weapon system), or (2) for
any use where chance of failure is intolerable (i.e., submersible repeater and artificial satellite). Please note that Spansion will not be liable to
you and/or any third party for any claims or damages arising in connection with above-mentioned uses of the products. Any semiconductor de-
vices have an inherent chance of failure. You must protect against injury, damage or loss from such failures by incorporating safety design mea-
sures into your facility and equipment such as redundancy, fire protection, and prevention of over-current levels and other abnormal operating
conditions. If any products described in this document represent goods or technologies subject to certain restrictions on export under the Foreign
Exchange and Foreign Trade Law of Japan, the US Export Administration Regulations or the applicable laws of any other country, the prior au-
thorization by the respective government entity will be required for export of those products.
Trademarks
Copyright © 2002–2006 Advanced Micro Devices, Inc. All rights reserved.
AMD, the AMD logo, and combinations thereof are registered trademarks of Advanced Micro Devices, Inc.
Product names used in this publication are for identification purposes only and may be trademarks of their respective companies.
May 10, 2006 27024B3
Am29BDS128H/Am29BDS640H
87
相关型号:
BS128HD9V
128 or 64 Megabit (8 M or 4 M x 16-Bit) CMOS 1.8 Volt-only Simultaneous Read/Write, Burst Mode Flash Memory
AMD
BS128HD9VF
128 or 64 Megabit (8 M or 4 M x 16-Bit) CMOS 1.8 Volt-only Simultaneous Read/Write, Burst Mode Flash Memory
AMD
BS128HE8V
128 or 64 Megabit (8 M or 4 M x 16-Bit) CMOS 1.8 Volt-only Simultaneous Read/Write, Burst Mode Flash Memory
AMD
BS128HE8VF
128 or 64 Megabit (8 M or 4 M x 16-Bit) CMOS 1.8 Volt-only Simultaneous Read/Write, Burst Mode Flash Memory
AMD
BS128HE9V
128 or 64 Megabit (8 M or 4 M x 16-Bit) CMOS 1.8 Volt-only Simultaneous Read/Write, Burst Mode Flash Memory
AMD
BS128HE9VF
128 or 64 Megabit (8 M or 4 M x 16-Bit) CMOS 1.8 Volt-only Simultaneous Read/Write, Burst Mode Flash Memory
AMD
BS1301-7PB2
DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid, METAL, CASE S02, MODULE
BEL
BS1301-7PD0
DC-DC Regulated Power Supply Module, 1 Output, Hybrid, HEAT SINK, METAL, CASE S02, MODULE
BEL
BS1301-7PD0B2
DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid, METAL, CASE S02, MODULE
BEL
©2020 ICPDF网 联系我们和版权申明