3CR63 [ALTECH]

Thermal Magnetic Circuit Breaker,;
3CR63
型号: 3CR63
厂家: ALTECH CORPORATION    ALTECH CORPORATION
描述:

Thermal Magnetic Circuit Breaker,

文件: 总1页 (文件大小:236K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
V-EA-Series - UL508 Manual Motor Controller - 3 pole C-Trip  
Rated  
Current  
0.3A  
0.5A  
0.75A  
0.8A  
1.0A  
1.6A  
2.0A  
2.5A  
3.0A  
3.5A  
4.0A  
5.0A  
6.0A  
8.0A  
10A  
Type/  
Cat. No.  
3CU03  
3CU05  
3CU075  
NA  
V-EA-C Trip  
0.3A Through 10A Rated Current  
Approvals  
U
1.13-1.45xIN  
L
UL508 Listed  
60  
40  
U
L
E137938  
U
L
10  
Thermal Overload  
“Must Trip” < 1 hr = 145% RC  
4
U
L
“Must Not Trip” > 1 hr = 113% RC  
1
3CU1  
3CU1.6  
3CU2  
Standard Pack: 4  
U
L
U
L
Weight:  
10  
4
U
0.3A - 63A  
1.68kg (3.7 lb.)  
3CU2.5  
3CU3  
L
U
L
1
U
L
3CU3.5  
3CU4  
0.4  
U
L
U
L
10-1  
3CU5  
3CU6  
3CU8  
U
L
4x10-2  
Three Pole  
U
L
10-2  
U
L
3CU10  
NA  
NA  
4x10-3  
12A  
10-3  
12.5A  
13A  
15A  
1
2
3
4
5 6 8 10  
20  
40  
100  
U
L
3CU13  
3CU15  
3CU16  
3CU20  
3CU25  
3CU30  
3CU32  
3CU40  
3CU50  
3CU60  
3CU63  
Multiple of Rated Current  
U
L
91.5 mm  
(3.60 in.)  
U
35 mm  
L
16A  
20A  
(1.38 in.)  
V-EA-C Trip  
13A Through 63A Rated Current  
U
L
U
L
25A  
30A  
1.13-1.45xIN  
U
L
60  
40  
U
L
32A  
40A  
U
10  
L
70 mm  
Thermal Overload  
“Must Trip” < 1 hr = 145% RC  
35 mm  
(1.38 in.)  
4
U
(2.76 in.)  
L
50A  
60A  
“Must Not Trip” > 1 hr = 113% RC  
1
U
L
63A  
10  
4
For ring tongue terminal version, replace “U”  
with “R” in part number. For example 1BR20  
instead of 1BU20.  
1
0.4  
Voltage Rating  
480Y/277VAC  
0.3-25A: 1 pole - 42VDC; 2 Pole - 80VDC  
30-60A: 1 pole - 24VDC; 2 Pole - 60VDC  
10-1  
4x10-2  
10-2  
0.3-60A (RC): 10kA with UL-listed  
RK5 back-up fuse or MCCB  
Short Circuit Withstand Rating  
(UL/CSA - Ratings)  
4x10-3  
10-3  
1
2
3
4
5 6 8 10  
20  
40  
100  
0.3-10A (RC): 10kA; 12-60A (RC): 5kA  
no branch circuit protection required  
Group Short Circuit Withstand Rating  
(UL/CSA - Ratings)  
Multiple of Rated Current  
0.3-63A (RC): 10kA  
Interrupting Capacity (VDE - Ratings)  
40°C (104°F)  
Calibration Temperature  
Terminal Size Acceptability  
Terminal Torque  
Top: 18-3 AWG; Bottom: 18-2 AWG  
20 lb.in.  
IP20  
Terminal Protection Degree  
short circuit Withstand ratings for v-ea manual motor controller  
Backup  
Protection  
UL-Listed  
RK5-Fuse  
up to 10kA  
UL-Listed  
MCCB  
up to 10kA  
No BCP  
Required  
up to:  
Trip  
Curve  
Amp Range  
0.3 - 10A  
all  
all  
all  
all  
4xRC*  
min 15A, max 70A  
4xRC*  
min 15A, max 70A  
10kA  
5kA  
5kA  
5kA  
12 - 30/32A  
40 - 50A  
4xRC*  
max 125A  
4xRC*  
max 125A  
4xRC*  
max 200A  
4xRC*  
max 200A  
60 / 63A  
4xRC*  
max 250A  
4xRC*  
max 250A  
*up to nearest rated current  

相关型号:

3CRE-30680

SPARK QUENCHER
OKAYA

3CRE-50500

SPARK QUENCHER
OKAYA

3CRH-30330

SPARK QUENCHER
OKAYA

3CRH-50270

SPARK QUENCHER
OKAYA

3CSH9

TASTER SMD SCHWARZ 1.3MM
ETC

3CSH9R

Through-hole or SMD
ETC

3CSKWH

COREX WIRE STRIPPER KIT 3CSKWH
ETC

3CT-P

RF BNC Connector, Male, Cable Mount, Clamp Solder Terminal, Plug
HRS

3CT-P(42)

RF BNC Connector,
HRS

3CT-P-1

RF BNC Connector, Male, Cable Mount, Clamp Solder Terminal, Plug
HRS

3CT-P3

RF BNC Connector, Male, Cable Mount, Clamp Solder Terminal, Plug
HRS

3CT06B

Half AC switching
JSMC