77230 [ALPHAWIRE]
Wire And Cable;EcoCable® and
EcoFlex™ Cable
Smaller. Lighter. Tougher. 100% Recyclable.
Total Performance,
Completely Recyclable
EcoCable and EcoFlex cable
are Alpha Wire’s newest
innovations in control
cabling. A true engineering
breakthrough, EcoCable and
EcoFlex cable combine better
performance with a minimum
environmental impact. Each
derives its advantages from
modified polyphenylene
ether (mPPE) jacketing and
insulation. EcoCable is:
• 100% Recyclable
• Up to 47% smaller
• Up to 65% lighter
• Capable of handling
temperatures extremes
to -50°C
• Up to 87% lower outgassing
mPPE Insulation:
All the Advantages in Smaller, Lighter Control Cable
Environmentally Friendly
Better Dielectric Strength
Superior Availability
EcoCable and EcoFlex cables
contain no halogens, phthalates,
or heavy metals. The mPPE
thermoplastic insulation
and jacketing can be easily
recycled. They meet RoHS
and WEEE requirements for
the elimination of hazardous
substances and recyclability.
The superior dielectric properties
of mPPE make a reduced
wall thickness possible, while
maintaining the same electrical
properties as a thicker PVC
control cable.
EcoCable and EcoFlex cable
are available from stock in most
sizes and constructions, with
put-ups as small as 100 feet.
Alpha Wire provides same-day
shipment and next-day delivery
to practically anywhere in
the world.
More Choice in EMI
Protection
Alpha Wire offers EcoCable
and EcoFlex cable in three
shielding options to handle any
electrical environment.
Visit www.alphawire.com/
EcoGen to request
free samples
Low Specific Gravity
The 1.03 specific gravity of
mPPE is 25% to 40% lower than
other insulation materials,
• Unshielded
such as PVC, polyethylene, and
cross-linked polyethylene. Along
with the reduced wall thickness,
the low specific gravity yields
significant weight savings of up
to 65% with EcoCable.
• Foil Shielded
• SupraShield® Foil + Braid Shield
Alpha Wire’s next generation of
eco-friendly, high-performance
wire and cable, designed to
provide better performance in a
smaller package.
• EcoCable®
• EcoFlex™ Cable
• EcoWire®
Properties
Diameter
Weight
EcoCable
Up to 47% smaller Up to 32% smaller
65% lighter
EcoFlex Cable
• EcoWire® Plus
55% lighter
Learn more about the new
EcoGen family of products at
www.alphawire.com/EcoGen
Temperature Range -50°C to 105°C
-40°C to 105°C static, -5°C to 105°C Flexing
91% lower
100%
Outgassing
Recyclability
Availability
87% lower
100%
100’, 1000’, Bulk
100’, 1000’, Bulk
Request free samples
at www.alphawire.com/
EcoCable
EcoCable
Specifications
Materials
Availability
Conductor No
Conductors:
Stranded tin-plated copper
Insulation: mPPE
100 ft (30.5 m) and
1000 ft (305 m) lengths
Bulk
No.
Base
1st
2nd
Color
Stripe
Stripe
1
Black
Brown
Red
2
Jacket: mPPE, slate
3
Approvals
• UL AWM 21915 (600V, 105°C)
• CSA AWM I/II A/B FT2
• CE
Electrical
Voltage: 600 V
4
Orange
Yellow
Green
Blue
5
6
Bend Radius
6x
• RoHS/RoHS2 Compliant
• REACH Compliant
• WEEE
7
8
Violet
Slate
Physical and Mechanical
Temperature Range:
-50°C to 105°C
9
• Suitable for use in
NFPA 79 applications
10
11
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
Black
Brown
Red
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Orange
Yellow
Green
Blue
Violet
Slate
22 AWG (0.35 mm2) Cable
Black
Black
Black
Black
Black
Black
Brown
Red
Orange
Yellow
Green
Blue
EcoCable
Unshielded
28 AWG (0.89 mm2)
22 AWG (0.35 mm2)
Stranding: 7/36 (0.127 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.032 (0.81 mm)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.032 (0.81 mm)
Nominal Diameter
Nominal Diameter
Part Number
Conductors
Part Number
Conductors
Inch
0.138
0.144
0.153
0.174
mm
3.51
Inch
0.168
0.189
0.204
0.219
0.251
0.318
mm
4.27
4.80
5.18
77052
77053
77054
77055
2
3
4
6
77007
77008
77009
77010
77011
2
4
5
3.66
3.89
4.42
7
5.56
6.38
8.08
9
77012
19
26 AWG (0.14 mm2)
Stranding: 7/34 (0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.032 (0.81 mm)
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.032 (0.81 mm)
Nominal Diameter
Part Number
Conductors
Inch
0.146
0.152
0.162
0.186
0.198
mm
3.71
3.86
4.11
Nominal Diameter
77047
77048
77049
77050
77051
2
3
4
6
8
Part Number
Conductors
Inch
0.193
0.209
0.280
0.309
0.336
0.358
0.416
mm
4.90
5.31
77013
77014
77015
77016
77017
77018
77019
3
4
4.72
5.03
9
7.11
12
15
19
25
7.85
8.53
9.09
10.57
24 AWG (0.28 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.032 (0.81 mm)
18 AWG (0.81 mm2)
Nominal Diameter
Part Number
Conductors
Inch
0.156
0.175
0.188
0.201
0.229
0.288
mm
3.96
4.44
4.78
5.11
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.012 (0.30 mm)
Jacket thickness: 0.032 (0.81 mm)
77001
77002
77003
77004
77005
77006
2
4
5
Nominal Diameter
Part Number
Conductors
Inch
0.206
0.217
0.235
0.255
0.276
0.320
0.355
0.387
0.414
0.482
mm
5.23
5.51
7
77020
77021
77022
77023
77024
77025
77026
77027
77028
77029
2
3
9
5.82
7.32
19
4
5.97
6.48
7.01
5
7
9
8.13
12
15
19
25
9.02
9.83
10.52
12.24
EcoCable
Foil Shield
16 AWG (1.32 mm2)
28 AWG (0.89 mm2)
Stranding: 19/0.0117 (19 x 0.297 mm)
Insulation thickness: 0.012 (0.30 mm)
Jacket thickness: 0.032 (0.81 mm)
Stranding: 7/36 (0.13 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.032 (0.81 mm)
Nominal Diameter
Nominal Diameter
Part Number
Conductors
Part Number
Conductors
Inch
0.269
0.293
0.319
0.371
0.413
0.451
0.484
0.566
mm
6.83
7.44
8.10
Inch
0.142
0.148
0.157
0.178
mm
3.61
77030
77031
77032
77033
77034
77035
77036
77037
4
5
77152
77153
77154
77155
2
3
4
6
3.76
3.99
4.52
7
9
9.42
10.49
11.46
12.29
14.38
12
15
19
25
26 AWG (0.14 mm2)
Stranding: 7/34 (0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.032 (0.81 mm)
14 AWG (2.08 mm2)
Nominal Diameter
Part Number
Conductors
Inch
0.15
mm
3.81
3.96
4.22
4.83
5.13
Stranding: 41/30 (41 x 0.25 mm)
Insulation thickness: 0.013 (0.33 mm)
Jacket thickness: 0.032 (0.81 mm)
77147
77148
77149
77150
77151
2
3
4
6
8
0.156
0.166
0.19
Nominal Diameter
Part Number
Conductors
Inch
0.260
0.275
0.301
0.329
0.358
0.419
0.467
0.511
mm
6.60
6.98
7.65
0.202
77038
77039
77040
77041
77042
77043
77044
77045
77046
2
3
4
24 AWG (0.28 mm2)
5
8.36
9.09
10.64
11.86
12.98
16.36
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.032 (0.81 mm)
7
9
12
15
25
Nominal Diameter
Part Number
Conductors
Inch
0.16
mm
4.06
4.24
4.55
4.88
5.21
0.644
77102
77103
77104
77105
77106
77107
77101
2
3
0.167
0.179
0.192
0.205
0.233
0.255
4
5
7
9
12
5.92
6.48
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.032 (0.81 mm)
Nominal Diameter
Part Number
Conductors
Inch
0.172
0.180
0.193
0.208
0.223
0.255
0.280
mm
4.37
4.57
4.90
5.28
5.66
6.48
7.11
77109
77110
77111
2
3
4
5
77112
77113
77114
77108
7
9
12
EcoCable
Foil Shield (continued)
20 AWG (0.56 mm2)
16 AWG (1.32 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.032 (0.81 mm)
Stranding: 19/0.0117 (19 x 0.297 mm)
Insulation thickness: 0.012 (0.30 mm)
Jacket thickness: 0.032 (0.81 mm)
Nominal Diameter
Nominal Diameter
Part Number
Conductors
Part Number
Conductors
Inch
mm
5.00
5.41
5.84
6.27
7.21
Inch
0.238
0.251
0.273
0.297
0.323
0.375
0.417
0.455
mm
6.05
6.38
6.93
7.54
8.20
9.52
10.59
11.56
77116
77117
77118
77119
77120
77115
3
4
5
0.197
0.213
0.230
0.247
0.284
0.313
77133
77134
77135
77136
77137
77138
77131
77132
2
3
4
5
7
9
12
7
7.95
9
12
15
18 AWG (0.81 mm2)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.012 (0.30 mm)
Jacket thickness: 0.032 (0.81 mm)
14 AWG (2.08 mm2)
Stranding: 41/30 (41 x 0.25 mm)
Insulation thickness: 0.013 (0.33 mm)
Jacket thickness: 0.032 (0.81 mm)
Nominal Diameter
Part Number
Conductors
Inch
0.210
0.221
0.239
0.259
0.281
0.324
0.359
0.391
0.418
0.486
mm
5.33
5.61
77124
77126
77127
77128
77129
77130
77121
77122
77123
77125
2
3
Nominal Diameter
Part Number
Conductors
Inch
0.264
0.279
0.305
0.333
0.362
0.423
0.471
0.515
mm
6.71
4
6.07
6.58
7.14
77141
77142
77143
77144
77145
77146
77139
77140
2
3
5
7.09
7.75
7
4
5
9
8.23
9.12
8.46
9.19
12
15
19
25
7
9.93
10.62
12.34
9
10.74
11.96
13.08
12
15
EcoCable
Supra-Shield® Foil + Braid
28 AWG (0.89 mm2)
18 AWG (0.81 mm2)
Stranding: 7/36 (0.13 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.032 (0.81 mm)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.012 (0.30 mm)
Jacket thickness: 0.032 (0.81 mm)
Nominal Diameter
Nominal Diameter
Part Number
Conductors
Part Number
Conductors
Inch
0.166
0.172
0.181
mm
4.22
4.37
4.60
5.13
Inch
mm
5.94
6.22
6.68
7.19
77252
77253
77254
77255
2
3
4
6
77213
77214
77215
77216
77217
77218
77219
77220
77221
2
3
0.234
0.245
0.263
0.283
0.305
0.348
0.383
0.414
0.442
4
0.202
5
7
7.75
9
8.84
9.73
10.52
11.23
26 AWG (0.14 mm2)
12
15
19
Stranding: 7/34 (0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.032 (0.81 mm)
Nominal Diameter
Part Number
Conductors
16 AWG (1.32 mm2)
Inch
0.174
0.18
mm
4.42
4.57
4.83
5.44
5.74
77247
77248
77249
77250
77251
2
3
4
6
8
Stranding: 19/ 0.0117 (19 x 0.297 mm)
Insulation thickness: 0.012 (0.30 mm)
Jacket thickness: 0.032 (0.81 mm)
0.19
0.214
0.226
Nominal Diameter
Part Number
Conductors
Inch
0.262
0.275
0.297
0.321
0.347
0.399
0.441
0.479
0.512
mm
6.65
6.98
7.54
8.15
77222
77223
77224
77225
77226
77227
77228
77229
77230
2
3
24 AWG (0.28 mm2)
4
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.032 (0.81 mm)
5
7
8.81
9
10.13
11.20
12.17
13.00
Nominal Diameter
Part Number
Conductors
12
15
19
Inch
0.203
0.229
0.279
mm
5.16
77201
77202
77203
4
7
5.82
7.09
12
14 AWG (2.08 mm2)
22 AWG (0.35 mm2)
Stranding: 41/30 (41 x 0.25 mm)
Insulation thickness: 0.013 (0.33 mm)
Jacket thickness: 0.032 (0.81 mm)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.032 (0.81 mm)
Nominal Diameter
Part Number
Conductors
Inch
mm
7.32
Nominal Diameter
Part Number
Conductors
77231
77232
77233
77234
77235
77236
77237
77238
2
3
0.288
0.303
0.329
0.386
0.447
0.495
0.539
0.678
Inch
0.217
0.247
0.304
mm
5.51
6.27
7.72
7.70
8.36
9.80
11.35
12.57
13.69
17.22
77204
77205
77206
4
7
4
7
12
9
12
15
25
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.032 (0.81 mm)
Nominal Diameter
Part Number
Conductors
Inch
0.237
0.254
0.271
0.308
0.337
0.386
mm
6.02
6.45
6.88
7.82
8.56
9.80
77207
77208
77209
77210
77211
4
5
7
9
12
19
77212
Request free samples
at www.alphawire.com/
EcoFlex
EcoFlex Cable
Specifications
Materials
Conductors:
Stranded tin-plated copper
Insulation: mPPE
Jacket: mPPE, slate
Key Features
Conductor No
• Compact cable for
No.
Base
Color
1st
Stripe
2nd
Stripe
moderate flex applications
• Rated for more than
1 million flex cycles
1
Black
Red
2
• Easier routing and handling
3
White
Green
Orange
Blue
Electrical
Voltage: 600 V
4
Approvals
• UL AWM 21819 (600 V, 105°C)
• UL AWM 21492 (300 V, 80°C)
• CE
5
6
Bend Radius
Unshielded: 5x Static, 5x Flexing
Shielded: 6x Static, 8x Flexing
7
Brown
Yellow
Violet
Slate
Pink
• UL VW-1
8
• RoHS Compliant
• CSA AWM I/II A/B FT1
• REACH Compliant
• WEEE
9
Physical and Mechanical
Temperature Range:
-40°C to 105°C
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Tan
• Suitable for use in
NFPA79 Applications
Red
Green
Yellow
Black
Black
Red
Availability
• IEC 60332-2 Flame Behavior
Red
100 ft (30.5 m) and
1000 ft (305 m) lengths
Bulk
Red
White
White
White
White
White
White
White
White
White
White
Green
Yellow
Blue
20 AWG (0.51 mm2) Cable
Brown
Orange
Slate
Violet
Black
Red
EcoFlex Cable
Unshielded
28 AWG (0.09 mm2)
22 AWG (0.38 mm2)
Stranding: 7/36 (7 x 0.13 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Stranding: 19/34 (19 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Nominal Diameter
Part Number
Conductors
Nominal Diameter
Inch
0.176
0.184
0.198
0.228
0.264
0.286
mm
4.47
4.67
5.03
5.79
6.71
Part Number
Conductors
Inch
mm
3.61
3.73
79044
79045
79046
79047
79048
79049
2
3
79061
79062
2
3
0.142
0.147
4
6
8
10
7.26
26 AWG (0.14 mm2)
20 AWG (0.51 mm2)
Stranding: 7/34 (7 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Stranding: 10/30 (10 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Nominal Diameter
Part Number
Conductors
Nominal Diameter
Inch
0.184
0.193
0.207
0.224
0.240
0.296
0.303
0.349
mm
4.67
4.90
5.26
5.69
6.10
7.52
7.70
8.86
Part Number
Conductors
Inch
0.150
0.156
0.166
0.189
0.216
mm
3.81
79001
79002
79003
79004
79005
79006
79007
79008
2
3
79056
79057
79058
79059
79060
2
3
4
6
8
3.96
4.22
4.80
5.49
4
5
7
9
12
18
24 AWG (0.24 mm2)
Stranding: 19/36 (19 x 0.13 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Nominal Diameter
Part Number
Conductors
Inch
0.162
0.169
0.181
mm
4.11
79050
79051
79052
79053
79054
79055
2
3
4.29
4.60
5.26
6.05
6.53
4
6
0.207
0.238
0.257
8
10
EcoFlex Cable
Unshielded
18 AWG (0.81 mm2)
14 AWG (2.08 mm2)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Stranding: 41/30 (41 x 0.25 mm)
Insulation thickness: 0.011 (0.28 mm)
Jacket thickness: 0.035 (0.81 mm)
Nominal Diameter
Inch
Nominal Diameter
Part Number
Conductors
Part Number
Conductors
mm
5.28
5.56
5.99
6.50
7.04
8.74
8.97
10.44
Inch
0.266
0.281
0.307
0.335
0.364
0.459
0.473
0.556
mm
6.76
7.14
79010
79011
79012
79013
79014
79015
79016
79017
2
3
0.208
0.219
0.236
0.256
0.277
0.344
0.353
0.411
79028
79029
79030
79031
79032
79033
79034
79035
2
3
4
5
4
5
7.80
8.51
7
7
9.25
11.66
12.01
14.12
9
9
12
18
12
18
16 AWG (1.32 mm2)
12 AWG (3.29 mm2)
Stranding: 26/30 (26 x 0.25 mm)
Insulation thickness: 0.011 (0.28 mm)
Jacket thickness: 0.035 (0.89 mm)
Stranding: 65/30 (65 x 0.25 mm)
Insulation thickness: 0.012 (0.30 mm)
Jacket thickness: 0.035 (0.81 mm)
Nominal Diameter
Nominal Diameter
Part Number
Conductors
Part Number
Conductors
Inch
0.236
0.249
0.270
0.294
0.319
0.400
0.411
mm
5.99
6.32
6.86
7.47
Inch
0.326
0.358
0.392
0.428
mm
8.28
9.09
9.96
10.87
79019
79020
79021
79022
79023
79024
79025
79026
2
3
79037
79038
79039
79040
3
4
5
7
4
5
7
8.10
9
10.16
10.44
12.22
12
18
0.481
10 AWG (5.32 mm2)
Stranding: 105/30 (105 x 0.25 mm)
Insulation thickness: 0.012 (0.30 mm)
Jacket thickness: 0.035 (0.81 mm)
Nominal Diameter
Part Number
Conductors
Inch
0.38
mm
9.65
10.74
11.81
79041
79042
79043
3
4
5
0.423
0.465
EcoFlex Cable
Braid Shield
20 AWG (0.51 mm2)
14 AWG (2.08 mm2)
Stranding: 10/30 (10 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Stranding: 41/30 (41 x 0.25 mm)
Insulation thickness: 0.011 (0.28 mm)
Jacket thickness: 0.035 (0.81 mm)
Nominal Diameter
Nominal Diameter
Part Number
Conductors
Part Number
Conductors
Inch
mm
5.33
5.56
5.92
6.35
6.76
8.15
Inch
0.294
0.309
0.335
0.363
0.392
mm
7.47
7.85
8.51
9.22
9.96
79101
79102
79103
79104
79105
79106
79107
79108
2
3
0.210
0.219
0.233
0.250
0.266
0.321
0.329
0.376
79121
79122
79123
79124
79125
2
3
4
5
7
4
5
7
9
12
18
8.36
9.55
18 AWG (0.81 mm2)
12 AWG (3.29 mm2)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Stranding: 65/30 (65 x 0.25 mm)
Insulation thickness: 0.012 (0.30 mm)
Jacket thickness: 0.035 (0.81 mm)
Nominal Diameter
Nominal Diameter
Part Number
Conductors
Part Number
Conductors
Inch
0.236
0.247
0.264
0.284
0.305
0.372
0.381
mm
5.99
6.27
6.71
7.21
Inch
0.354
0.386
mm
8.99
9.80
79109
79110
79111
79112
79113
79114
79115
2
3
79126
79127
3
4
4
5
7
7.75
9.45
9.68
9
12
16 AWG (1.32 mm2)
Stranding: 26/30 (26 x 0.25 mm)
Insulation thickness: 0.011 (0.28 mm)
Jacket thickness: 0.035 (0.89 mm)
Nominal Diameter
Part Number
Conductors
Inch
0.262
0.275
0.296
0.320
0.345
mm
6.65
6.98
7.52
8.13
79116
79117
79118
79119
79120
2
3
4
5
7
8.76
EcoFlex Cable
Supra-Shield® Foil + Braid
28 AWG (0.09 mm2)
24 AWG (0.24 mm2)
Stranding: 7/36 (7 x 0.13 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Stranding: 19/36 (19 x 0.13 mm)
Insulation thickness: 0.011 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Nominal Diameter
Nominal Diameter
Part Number
Conductors
Part Number
Conductors
Inch
0.174
0.179
mm
4.42
4.55
Inch
0.194
0.201
0.213
0.239
0.27
mm
4.93
5.11
79261
79262
2
3
79250
79251
79252
79253
79254
79255
2
3
4
5.41
6.07
6.86
7.34
6
8
10
0.289
26 AWG (0.14 mm2)
22 AWG (0.38 mm2)
Stranding: 7/34 (7 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Stranding: 19/34 (19 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Nominal Diameter
Nominal Diameter
Part Number
Conductors
Part Number
Conductors
Inch
0.182
0.188
0.198
0.221
0.248
mm
4.62
4.78
5.03
5.61
Inch
0.208
0.216
0.23
mm
5.28
5.49
5.84
6.60
7.52
8.08
79256
79257
79258
79259
79260
2
3
4
6
8
79244
79245
79246
79247
79248
79249
2
3
4
6
0.26
6.30
8
0.296
0.318
10
20 AWG (0.51 mm2)
Stranding: 10/30 (10 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Nominal Diameter
Part Number
Conductors
Inch
0.216
0.225
0.239
0.256
0.272
0.328
0.335
0.382
mm
5.49
5.72
6.07
6.50
6.91
8.33
8.51
79201
79202
79203
79204
79205
79206
79207
79208
2
3
4
5
7
9
12
18
9.70
EcoFlex Cable
Supra-Shield® Foil + Braid
18 AWG (0.81 mm2)
12 AWG (3.29 mm2)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Stranding: 65/30 (65 x 0.25 mm)
Insulation thickness: 0.012 (0.30 mm)
Jacket thickness: 0.035 (0.81 mm)
Nominal Diameter
Nominal Diameter
Part Number
Conductors
Part Number
Conductors
Inch
0.242
0.253
0.270
0.290
0.311
mm
6.15
Inch
0.360
0.391
0.426
0.462
mm
9.14
79210
79211
79212
79213
79214
79215
79216
79217
2
3
79232
79233
79234
79235
3
4
5
7
6.43
6.86
7.37
7.90
9.60
9.83
11.30
9.93
10.82
11.73
4
5
7
9
0.378
0.387
0.445
12
18
16 AWG (1.32 mm2)
10 AWG (5.32 mm2)
Stranding: 26/30 (26 x 0.25 mm)
Insulation thickness: 0.011 (0.28 mm)
Jacket thickness: 0.035 (0.89 mm)
Stranding: 105/30 (105 x 0.25 mm)
Insulation thickness: 0.012 (0.30 mm)
Jacket thickness: 0.035 (0.81 mm)
Nominal Diameter
Nominal Diameter
Part Number
Conductors
Part Number
Conductors
Inch
0.268
0.281
0.302
0.326
0.351
0.432
0.443
mm
6.81
Inch
0.419
0.457
mm
10.64
11.61
79218
79219
79220
79221
79222
79223
79224
2
3
79236
79237
3
4
7.14
4
5
7.67
8.28
8.92
10.97
11.25
7
9
12
14 AWG (2.08 mm2)
Stranding: 41/30 (41 x 0.25 mm)
Insulation thickness: 0.011 (0.28 mm)
Jacket thickness: 0.035 (0.81 mm)
Nominal Diameter
Part Number
Conductors
Inch
0.300
0.315
0.341
0.369
0.398
0.493
0.507
mm
7.62
79225
79226
79227
79228
79229
79230
79231
2
3
8.00
8.66
9.37
10.11
4
5
7
9
12
12.52
12.88
Cables you trust.
Service you deserve.
Service and support,
second-to-none
Superior availability
Every application is critical
and cable failure is not an
option when the safety of your
equipment and personnel is
paramount. Specify Alpha
products since the integrity of
your system is only as robust as
the products you use.
Alpha offers wire and cable
from stock in most sizes and
constructions, in both small
and large put-ups, so you can
order it when you need it.
Our products are available for
same-day shipment,
Selecting the correct cable
for your critical application
is essential to overall system
reliability, performance, and
safety. So we make it easy for
you to select the right Alpha
product for your specific
eliminating long lead times.
application. Our online
resources include a wire and
cable selection guide, technical
information, full product
catalog, and a distributor
locator to make it easy to select
and get the wire or cable you
need. Can’t find what you’re
looking for? Design the cable to
your specification. It’s easy, just
visit www.alphawire.com!
GLOBAL HEADQUARTERS
711 Lidgerwood Avenue
Elizabeth, NJ 07207-0711 USA
Toll Free: 1-800-52 ALPHA
Tel: 1-908-925-8000
EUROPE
Alpha Wire International
Saxon House
1 Downside | Sunbury-on-Thames
Middlesex | United Kingdom
TW16 6RT
Tel: +44-(0)-800-288-8809
Fax: +44-(0)-800-288-8810
E-mail: europe@alphawire.com
ASIA PACIFIC
Alpha Wire
Silver Center | Room 1708
North Shanxi Road 1388
Shanghai | China | 200060
Tel: +86-21-61498201/61498205
Fax: +86-21-61498001
Fax: 1-908-925-5411
E-mail: info@alphawire.com
E-mail: apac@alphawire.com
Alpha Wire’s next generation of
eco-friendly, high-performance
wire and cable, designed to
provide better performance in a
smaller package.
©2013 Alpha Wire. All rights reserved. Specifications subject to change.
Consult Alpha Wire for latest specifications. EcoCable, EcoFlex, EcoGen, EcoWire, and EcoWire Plus are trademarks of Alpha Wire.
Lit. No. EcoC-Bro-1311
Supersedes: EcoC-Bro-1308