700-SH25GA12 [ALLEN-BRADLEY]

Solid-State Relays; 固态继电器
700-SH25GA12
型号: 700-SH25GA12
厂家: Allen-Bradley    Allen-Bradley
描述:

Solid-State Relays
固态继电器

继电器 固态继电器
文件: 总7页 (文件大小:598K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Bulletin 700-SH  
Solid-State Relays  
Overview/Product Selection  
Table Of Contents  
Bulletin 700-SH  
Product Selection . . . . . . . 51  
Accessories . . . . . . . . . . . . 52  
Specifications . . . . . . . . . . 53  
Approximate  
Dimensions . . . . . . . . . . . . 56  
40 A (resistive) Max. Continuous Load (Output) Current with Heat Sink  
264V AC or 528V AC Max. Load Voltage Range Options  
5…24V DC, 100…120V AC, 200…240V AC Control Input Voltage  
LED Indicator for Input/Logic ON/OFF Status Monitoring  
Built-in Varistor to Absorb Most Surges  
Protective Cover for Added Safety (Meets VDE 106 Finger Safe Standard)  
Basic Application  
Considerations . . . . . . . . . 57  
Product Selection  
Factory-  
Stocked  
Item  
(Single  
Pack)  
Input-to-Output  
Isolation  
Rated Output (Load)  
Max. Current and  
Voltage Range ➊  
Zero Cross  
Function  
LED  
Indicator  
Rated Input  
Control Voltage  
Cat. No.  
Method  
Phototriac  
Photocoupler  
Phototriac  
5…24V DC  
100…120V AC  
200…240V AC  
5…24V DC  
700-SH05GZ25  
700-SH05GA12  
700-SH05GA22  
700-SH10GZ25  
700-SH10GA12  
700-SH10GA22  
700-SH10HZ25  
700-SH25GZ25  
700-SH25GA12  
700-SH25GA22  
700-SH25HZ25  
700-SH40GZ25  
700-SH40GA12  
700-SH40GA22  
700-SH40HZ25  
5 A @ 24…240V AC  
10 A @ 24…240V AC  
10 A @ 200…480V AC  
25 A @ 24…240V AC  
25 A @ 200…480V AC  
40 A @ 24…240V AC  
40 A @ 200…480V AC  
100…120V AC  
200…240V AC  
5…24V DC  
Photocoupler  
Phototriac  
Yes  
Yes  
5…24V DC  
100…120V AC  
200…240V AC  
5…24V DC  
Photocoupler  
Photocoupler  
Phototriac  
5…24V DC  
100…120V AC  
200…240V AC  
5…24V DC  
Photocoupler  
Maximum load current when mounted on a heat sink  
51  
Bulletin 700-SH  
Solid-State Relays  
Accessories  
Description  
Pkg. Qty  
Cat. No.  
Factory-Stocked Item  
Heat Sink— Panel or DIN  
1
700-S10  
Rail Mount ➊  
Cat No. 700-S10  
Heat Sink— Panel or DIN  
1
700-S20  
Rail Mount ➊  
Cat No. 700-S20  
Heat Sink— Panel or DIN  
1
700-S30  
Rail Mount ➊  
Cat No. 700-S30  
DIN Rail Mounting Pack  
Standard 35 x 7.5 mm DIN  
Rail, 1 meter long, 10 rails  
per package. Order must  
be for 10 rails or multiples  
of 10.  
10  
199-DR1  
Cat No. 199-DR1  
For information regarding selection of the proper heat sink for your application, refer to "Heat Sink Size Vs. Load Current" graph on page 54 or "Load Current Vs.  
Ambient Temperature Characteristics" on page 55.  
52  
Bulletin 700-SH  
Solid-State Relays  
Specifications  
Control/Input Ratings  
Rated Control  
Voltage  
Operating Control  
Voltage Range  
Cat. No.  
Impedance ➊  
Control Voltage Levels  
Pick-up Voltage  
4V DC max.  
Drop-out Voltage  
1V DC min.  
5...24V DC  
4...32V DC  
15 mA max ➊  
700-SH_ _G…  
100...120V AC  
200...240V AC  
5...24V DC  
75...132V AC  
150…264V AC  
4…32V DC  
36 k+/-20%  
72 k+/-20%  
75V AC max. ➊  
150V AC max. ➊  
4V DC max.  
20V AC min. ➊  
40V AC min. ➊  
1V DC min.  
700-SH_ _ H…  
Cat. No.  
5 mA max. ➊  
Load/Output Ratings  
Applicable Load  
Continuous Load  
Current (Resistive)  
Rated Load  
Voltage  
Load Voltage  
Range  
With Heat Sink (A) ➊  
Without Heat Sink (A) ➊  
Max. Inrush Current➊  
Min.  
Max.  
Min.  
Max.  
3 A  
4 A  
4 A  
4 A  
4 A  
6 A  
6 A  
700-SH05G…  
700-SH10G…  
700-SH10H…  
700-SH25G…  
700-SH25H…  
700-SH40G…  
700-SH40H…  
0.1 A  
0.1 A  
0.2 A  
0.1 A  
0.2 A  
0.1 A  
0.2 A  
5 A  
0.1 A  
0.1 A  
0.2 A  
0.1 A  
0.2 A  
0.1 A  
0.2 A  
60 A (@50/60 Hz, 1 cycle)  
24…240V AC  
19 …264V AC  
10 A  
10 A  
25 A  
25 A  
40 A  
40 A  
150 A (@50/60 Hz, 1  
cycle)  
200…480V AC  
24…240V AC  
200…480V AC  
24…240V AC  
200…480V AC  
180…528 VAC  
19…264V AC  
180…528V AC  
19…264V AC  
180…528V AC  
220 A (@ 50/60 Hz, 1  
cycle)  
440 A (@ 50/60 Hz, 1  
cycle)  
The input impedance is measured at the maximum value of the rated supply voltage.  
With a constant current input system, SSR impedance varies with a change in input voltage.  
Refer to graphs, “Temperature Characteristics…” and “Must Release Voltage” on page 54 for further details.  
When specified heat sink is used. Refer to accessories, page 52 for applicable heat sinks. For more details, refer to graphs “Load Current Vs. Ambient Temperature  
Characteristics” on page 55, and the “Heat Sink vs. Load Current” graph on page 54.  
If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. Refer to “Inrush Current Resistivity” graphs on page 54 for more details.  
53  
Bulletin 700-SH  
Solid-State Relays  
Specifications, Continued  
Characteristics  
Cat. No.  
700-SH05G, -SH10G, SH25G  
700-SH40G  
700-SH10H, -SH25H, SH40H  
Load Switching Method/  
Device  
Triac  
Thyristor  
1/2 of load power source + 1 ms max. (DC input)  
3/2 of load power source + 1 ms max. (AC input)  
Pick-up Time  
1/2 of load power source + 1 ms max. (DC input)  
3/2 of load power source + 1 ms max. (AC input)  
Drop-out Time  
Output ON Voltage Drop  
1.6 V (RMS) max  
1.8 V (RMS) max  
10 mA max. (@ 200V AC)  
20 mA max. (@ 400V AC)  
1200  
5 mA max (at 100V AC)  
10 mA max (at 200V AC)  
Output Leakage Current  
Output VDRM, VCEO (V)  
600  
600  
50  
-SHO5G = 100,  
-SHO10G, -SH25G= 50  
Output di/dt (A/uS)  
100  
300  
-SHO5G = 200,  
-SHO10G, -SH25G= 100  
Output dv/dt (V/uS)  
100  
-SHO5G = 24.5,  
-SHO10G=112.5 -SH25G= 260  
2
Output I t (A2S)  
1260  
260, SH40 = 1800  
Output Tj °C Max.  
Insulation Resistance  
Dielectric Strength  
125  
100 Mmin (at 500 VDC)  
2,500V AC, 50/60 Hz for 1 minute  
10…55 Hz, 1.5 mm double amplitude (10 G)  
1,000 m/s2 (100 G)  
Vibration Resistance (max.)  
Shock Resistance (max.)  
Operating: -30°C…80°C (-22°F…176°F) with no icing or condensation  
Ambient Temperature  
Storage: -30°C…100°C (-22°F…212°F) with no icing or condensation  
Operating: 45%…85% (no condensation)  
Ambient Humidity  
Standards ➊  
Weight  
UL508, CSA C22.2, CE, TÜV  
Approx. 60g  
Approx. 70g  
Approx. 80g  
Cat. No. 700-SH_ _ _HZ25 not CE or TÜV approved.  
Inrush Current Resistivity➊  
Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period of time. Surges are considered non-repetitive (max. repeatability  
once every 2…5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.  
The heat sink size refers to the combined area of the sides of the heat sink that radiate heat. For example, when a current of 18 A is allowed to flow through the SSR  
at 40°C, the graph shows that the heat sink size is about 450 cm2. Therefore, if the heat sink is square, one side of the heat sink must be 15 cm (152 x 2 = 450) or longer.  
54  
Bulletin 700-SH  
Solid-State Relays  
Specifications, Continued  
Load Current vs. Ambient Temperature Characteristics➊  
For the above 5 graphs, the line “with iron plate measuring 100 x 100 x 0.8” means the SSR is mounted directly to an iron plate of at least this size.  
All graphs assume conductive grease is being used. Refer to page 56 for details of using conductive grease.  
55  
Bulletin 700-SH  
Solid-State Relays  
Approximate Dimensions  
Mounting Considerations➊➊➊➊  
All units are in millimeters unless otherwise indicated. Dimensions are not intended for manufacturing purposes.  
Terminal Arrangement/  
Internal Connections (Top  
View)  
Four, M4 x 8  
screws  
4.5 dia.  
Mounting Holes  
Two, 4.3-dia.  
or M4 holes  
Load  
Load  
power  
58 max. 47.5 44  
supply  
Load  
2
1
47.6±0.2  
(-)  
4
(+)  
3
Operating  
indicator  
13.8  
4.5  
25  
43 max.  
Input  
25 max.  
27 max.  
Cat. No. 700-SH05…  
4.5 dia.  
Two, M5 x 12 screws  
Mounting Holes  
Two, 4.3-dia.  
or M4 holes  
58 min.47.5 44  
47.6±0.2  
Operating  
indicator  
13.8  
4.5  
25  
25 max.  
27 max.  
Two,  
M 4 x 8  
Cat. No. 700-SH40  
43 max.  
The proper mounting orientation of the heat sink is so the heat fins run perpendicular to the floor (vertical) to maximize ventilation flow.  
If the fins do not run perpendicular to the floor, a 30% current derating is required.  
When attaching a heat sink to Bulletin 700-SH, apply heat conductive grease on the heat sink to maximize heat transfer between the SSR and the heat sink.  
Recommended types: Silicon based, Toshiba YG6240; Non-silicon based, AOS company type 53300.  
Tighten the SSR panel/heat sink mounting screws to a torque of 0.78…0.98 Nm (6.9…8.7 lb-in).  
Tighten the SSR terminal wiring screws as follows M4: 0.98…1.37 Nm (8.67…12.12 lb-in.), M5: 1.57…2.35 Nm (13.89…20.8 lb-in.)  
Heat Sinks➊ ➊  
Mounting Holes  
Two, M3 holes  
4.6 dia.  
35±0.2  
Two, 3.2-dia.  
holes  
Two, M4 holes  
44 max. 30  
47 max.  
4.5  
35 30.5 0.3  
Two, 4.4-dia.  
or M4 holes  
90±0.4  
47.6  
5.6  
5
6
77 max.  
90±0.3  
51 max.  
Cat. No. 700-S10  
100 max.  
Mounting Holes  
Two, M4  
holes  
Two, M3 holes  
Two, 3.2-dia. holes  
4.6 dia.  
35±0.2  
71 max.  
35 30.5±0.3  
30  
75 max.  
Two, 4.4-dia.  
or M4 holes  
90±0.4  
28  
5
13  
4.5  
47.6  
77 max.  
90±0.3  
5.6  
100 max.  
Cat. No. 700-S20  
100 max.  
47.6  
Two, 3.2-dia. holes  
Mounting Holes  
Three,  
M4  
holes  
35±0.2  
4.6 dia.  
35  
Two, 4.4-dia.  
or M4 holes  
100 max. 30  
104 max.  
90±0.4  
28  
5.6  
5
100 max.  
13  
4.5  
56±0.3  
77 max.  
90±0.3  
Cat. No. 700-S30  
100 max.  
Tighten the heat sink mounting screws (M4) to a torque of 0.98…1.37 Nm (8.67…12.12 lb-in).  
Heat sink weight: cat. nos. 700-S10 = 200 g, 700-S20 = 400 g, 700-S30 = 560 g  
56  
Bulletin 700-SH  
Solid-State Relays  
Basic Application Considerations  
Load Connection  
For an AC load, use a power supply rated at 50 or 60 Hz. The maximum operating frequency is 10 Hz.  
The Bulletin 700-SH has a built-in varistor for surge/inrush protection of AC loads. If additional suppression is required, connect an external  
varistor across the load device terminals. Select a varistor which meets the load voltage condition outlined in the table below.  
Load Voltage  
100…120V AC  
200…240V AC  
380…480V AC  
Varistor Voltage  
240…270 V  
Varistor Surge Resistance  
440…470V  
1000 A min.  
820…1000V  
Zero Cross Function  
A SSR with a zero cross function operates when an AC load voltage reaches the zero point or its vicinity. This reduces clicking noises when the load is  
switched, and minimizes the influence of an inductive load, such as a lamp, heater, or motor, on the power supply because the inrush current of the load is  
reduced. This can also minimize the scale of the inrush current protection circuit.  
Output (load voltage)  
ON  
Input  
OFF  
At a low applied voltage, such as 24V AC, the load current is not fully supplied. When the unit is switched ON, the voltage required to power the unit deprives  
the output signal of the necessary voltage level and thus creates loss time. The lower the load voltage is, the greater the loss time is. This condition, however,  
will not create any serious problems.  
Loss time  
For a DC inductive load, a diode should be connected parallel to the load to absorb the counter electromotive force (OFF) of the load.  
Load  
Load power  
supply  
Input  
SSR  
Note: For additional details when using Solid-State Relays, refer to pub. 700-AT001A--EN-E, “Solid-State Relay Application Guide" available at  
www.theautomationbookstore.com.  
57  

相关型号:

700-SH25GA22

Solid-State Relays
ALLEN-BRADLEY

700-SH25GZ25

Solid-State Relays
ALLEN-BRADLEY

700-SH25HZ25

Solid-State Relays
ALLEN-BRADLEY

700-SH40GA12

Solid-State Relays
ALLEN-BRADLEY

700-SH40GA22

Solid-State Relays
ALLEN-BRADLEY

700-SH40GZ25

Solid-State Relays
ALLEN-BRADLEY

700-SH40HZ25

Solid-State Relays
ALLEN-BRADLEY

700-SK

Solid-State Relays
ALLEN-BRADLEY

700-SKICA18

Solid-State Relays
ALLEN-BRADLEY

700-SKICZ24

Solid-State Relays
ALLEN-BRADLEY

700-SKOC1Z25

Solid-State Relays
ALLEN-BRADLEY

700-SKOC2Z25

Solid-State Relays
ALLEN-BRADLEY