2032-C0085PX-26D [ALLEN-BRADLEY]

ElectroGuard; ElectroGuard
2032-C0085PX-26D
型号: 2032-C0085PX-26D
厂家: Allen-Bradley    Allen-Bradley
描述:

ElectroGuard
ElectroGuard

文件: 总9页 (文件大小:165K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Safety Isolation System  
ElectroGuard  
Overview  
Status Com m unication Capability to a Rem ote PLC  
Optional Remote I/O via Flex modules. Communication can be  
via the DeviceNet communication platform or the Remote I/O  
communication platform.  
Available from 23-1200 Am peres.  
Specifications  
UL Listed Industrial Control Panel;  
Approvals  
C
US  
TUV Rheinland certified; CE marked  
for all applicable directives  
IEC/EN 60204-1; IEC/EN 60439-1;  
Category 4 to International Standard  
EN 954-1/ISO 13849-1; 98/37/EC  
Machinery Directive; 89/336/EC EMC  
Directive; 73/23/EC Low Voltage  
Directive; Fulfils the function of an  
energy isolating device in accordance  
with the conditions set forth in the  
FedOSHA letter of interpretation  
pertaining to Section 1910.147(b);  
Cal/OSHA 3314.  
Standards  
The ElectroGuard Safety Isolation System is used in place of a  
disconnect switch for Lockout and Tagout (LOTO). It uses power  
contactors and Remote Lockout Stations to accomplish LOTO.  
Isolating the electrical energy usually involves calling an electrician to  
turn “Offthe main disconnecting means. The electrician would  
then perform LOTO of the disconnecting means operating handle.  
Estimated Component Life  
Remote Lockout Station 250,000 operations  
Power Contactors 23A - 85A: 2,000,000 operations  
(Isolation & Grounding) 110A-1200A: 1,000,000 operations  
This same procedure is required to perform cleaning, maintenance,  
setup, lubrication or adjustment. Machines or processes with  
multiple access points may require operator/maintenance  
intervention several times a shift (perhaps as often as 60 times per  
shift).  
Environmental  
Storage Temperature -10°C...+60°C (14°F...140°F)  
Operating Temperature 0°C...+40°C (32°F...104°F) (Ambient)  
Relative Humidity,  
90% Relative Humidity  
Non condensing  
To perform these activities, the operator/maintenance person may  
be required to place part of his or her body into an area not accessed  
during normal operation. This may cause serious or fatal injury if  
LOTO procedures are not followed.  
Power Panel Construction  
Tamper-resistant Control Module  
23A-85A systems support up to 4  
Remote Lockout Stations without an  
Expansion Module  
The ElectroGuard Safety Isolation System allows the machine  
operator to safely and quickly accomplish LOTO with dramatically  
reduced downtime.  
110A-1200A systems support up to 6  
Remote Lockout Stations without an  
Expansion Module  
Provides Energy Isolation  
Control Module with viewing window  
for visual check of status indicator lights  
Power isolation accomplished by means of contactors rather than  
disconnect switches.  
Top and bottom 25.4mm (1.0in)  
conduit entry (removable plug in  
bottom conduit hole)  
Remote Lockout Station  
Construction  
Uses redundant, independent and self-monitoring circuits to  
detect a system fault.  
Sealing provision for tamper-resistance  
Prevents accumulation of faults in order to maintain the integrity  
of the safety system.  
Tamper-resistant design.  
Operating handle accepts up to 3  
padlocks  
4 port—supports up to 4 lockout  
stations  
• allows the systems to  
accommodate up to 24 Remote  
Lockout Stations  
10 port—supports up to 10 lockout  
stations  
• allows the systems to  
accommodate up to 60 Remote  
Lockout Stations  
Window for viewing status indicator  
lights; Sealed for tamper-resistance  
Expansion Module  
Construction  
Convenient Rem ote Lockout Station  
Allows remote isolation of the electrical power to the machine or  
process—machine operator simply turns “Off” a Remote  
Lockout Station.  
A light on the Remote Lockout Station indicates that the three-  
phase power source to the machine or process has been isolated.  
No Light Mea ns No Entr y.  
If a fault occurs in the Safety Isolation System, the “System  
Isolated” light on the Remote Lockout Stations will not  
illuminate.  
Easy Lockout/Tagout.  
Safety Isolation Sys. Inputs  
Standard Inputs from Remote Lockout Stations  
Certified by TUV to m eet requirem ents of Category 4  
Optional Inputs from  
Rockwell Automation  
Safety Products  
Certified by TUV to meet Category 4, the most stringent safety  
category defined within International Standard EN 954-1/ISO  
13849-1.  
Subjected by TUV to rigorous third party testing and verification  
of the Failure Mode & Effect Analysis (FMEA).  
Safety Mats, ➊  
Light Curtains, ➊  
E-Stop Stations, ➊  
Proximity Switches, ➊  
Photo Switches ➊  
System Operational Limits  
+10%, -15% of the line voltage  
Use of any of these input devices will not meet Lockout/Tagout (LOTO)  
requirements.  
12-2  
Safety Isolation System  
ElectroGuard  
Overview  
Principle of Operation  
After using the normal stopping  
method of the machine or process,  
the machine operator turns a  
Remote Lockout Station handle  
from the “On” to “Offposition.  
The station signals the isolation  
contactors (1IC and 2IC) to drop  
out and isolate the supply voltage  
from the loads (see Control  
Circuit).  
Power Circuit  
2IC  
1IC  
Incoming  
3 Phase  
Power  
To M o to r  
To Lo ad s  
Controllers  
H1 H2  
GC  
Trans.  
X2  
X1  
Control Power  
Voltage  
Decay  
Relays  
(VDR)  
When system residual voltage  
decays to pre-determined levels,  
the grounding contactor (GC) is  
energized, connecting the load to  
ground (see Power Circuit). The  
grounding contactor (GC) is  
electrically and mechanically  
interlocked with the isolation  
contactors (1IC and 2IC).  
Grd  
Disconnecting  
Means/Branch  
Circuit Protection ➊  
The “System Isolated” Light will  
now illuminate on the Remote  
Lockout Station to indicate the  
system is isolated. The machine  
operator then Locks-Out and  
Tags-Out the station in the “Off”  
position.  
Control Circuit  
Remote Lockout Station  
Off  
On  
GC  
1IC  
Mechanically  
Interlocked  
GC  
2IC  
VDR  
GC  
1IC  
1IC  
2IC  
1IC, 2IC, &  
GC are  
mechanically  
and electrically  
interlocked  
GC  
System Isolated (*)  
2IC  
(*) = “On” when the Remote  
Lockout Station switch is “Off”  
Available factory installed within the ElectroGuard as an option.  
Optional Features  
Four (4) or ten (10) port Expansion Modules to permit additional Remote  
Lockout Stations to be used (see page 12-16 for details).  
Pneumatic Isolation Module to isolate pneumatic energy (see page 12-15 for  
details).  
Status communication to a remote PLC (see page 12-17 for details).  
Fusible disconnect switch (Bulletin 2032) or thermal-magnetic circuit breaker  
(Bulletin 2033) to provide branch circuit protection.  
Optional Pneumatic Isolation Module  
12-3  
Safety Isolation System  
ElectroGuard  
Combination Systems with Fusible Disconnect Switch  
Product Selection for Outside of North America (see page 12-19 for Ordering Instructions)  
3-Phase Max. kW Rating  
(50Hz)  
Catalogue Num ber ➊  
IP 54 Motor Control  
Am p.  
Fuse Clip  
Rating/  
Rating  
Centre Type Enclosure  
(with bussing)  
(AC-3) 230V 400V 500V 600V Ty p e ➊  
IP 30 Enclosure  
IP 54 Enclosure  
IP 65 Enclosure  
2032-C0023W -23B  
2032-C0023W -24B  
2032-C0023W -25B  
2032-C0023W -25D  
2032-C0043W -25B  
2032-C0043W -25D  
2032-C0043W -26B  
2032-C0043W -26D  
2032-C0085W -26B  
2032-C0085W -26D  
2032-C0085W -27B  
2032-C0085W -27D  
2032-C0110W -26B  
2032-C0110W -26D  
2032-C0110W -27B  
2032-C0110W -27D  
2032-C0110W -28D  
2032-C0180W -27B  
2032-C0180W -28D  
2032-C0180W -29B  
2032-C0180W -29D  
2032-C0210W -27B  
2032-C0210W -28D  
2032-C0210W -29B  
2032-C0210W -29D  
2032-C0300W -29B  
2032-C0300W -29D  
2032-C0300W -30B  
2032-C0300W -30D  
2032-C0420W -29B  
2032-C0420W -29D  
2032-C0420W -30B  
2032-C0420W -30D  
2032*-C0630W -30B  
20A BS 88 2032-C0023P -23B 2032-C0023H -23B  
2032-!0023H -23B  
2032-!0023H -24B  
2032-!0023H -25B  
2032-!0023H -25D  
2032-!0043H -25B  
2032-!0043H -25D  
2032-!0043H -26B  
2032-!0043H -26D  
2032-!0085H -26B  
2032-!0085H -26D  
2032-!0085H -27B  
2032-!0085H -27D  
2032-!0110H -26B  
2032-!0110H -26D  
2032-!0110H -27B  
2032-!0110H -27D  
2032-!0110H -28D  
2032-!0180H -27B  
2032-!0180H -28D  
2032-!0180H -29B  
2032-!0180H -29D  
2032-!0210H -27B  
2032-!0210H -28D  
2032-!0210H -29B  
2032-!0210H -29D  
2032-!0300H -29B  
2032-!0300H -29D  
2032-!0300H -30B  
2032-!0300H -30D  
2032-!0420H -29B  
2032-!0420H -29D  
2032-!0420H -30B  
2032-!0420H -30D  
2032-!0630H -30B  
2032-C0023P -24B 2032-C0023H -24B  
2032-C0023P -25B 2032-C0023H -25B  
32A BS 88  
63A BS 88  
23  
43  
85  
5.5  
11  
22  
11  
22  
45  
11  
22  
45  
11  
22  
45  
63A DIN 2032-C0023P -25D 2032-C0023H -25D  
2032-C0043P -25B 2032-C0043H -25B  
2032-C0043P -25D 2032-C0043H -25D  
63A BS 88  
63A DIN  
100A BS 88 2032-C0043P -26B 2032-C0043H -26B  
2032-C0043P -26D 2032-C0043H -26D  
2032-C0085P -26B 2032-C0085H -26B  
100A DIN  
100A BS 88  
100A DIN 2032-C0085P -26D 2032-C0085H -26D  
200A BS 88 2032-C0085P -27B 2032-C0085H -27B  
2032-C0085P -27D 2032-C0085H -27D  
160A DIN  
100A BS88 2032-C0110P -26B 2032-C0110H -26B  
100A DIN 2032-C0110P -26D 2032-C0110H -26D  
2032-C0110P -27B 2032-C0110H -27B  
110  
32  
55  
63  
100 200A BS 88  
160A DIN 2032-C0110P -27D 2032-C0110H -27D  
250A DIN 2032-C0110P -28D 2032-C0110H -28D  
2032-C0180P -27B 2032-C0180H -27B  
200A BS 88  
250A DIN 2032-C0180P -28D 2032-C0180H -28D  
400A BS 88 2032-C0180P -29B 2032-C0180H -29B  
180  
210  
300  
45  
63  
90  
90  
110  
150  
200  
110  
200  
257  
425  
2032-C0180P -29D 2032-C0180H -29D  
400A DIN  
200A BS 88 2032-C0210P -27B 2032-C0210H -27B  
250A DIN 2032-C0210P -28D 2032-C0210H -28D  
110  
160  
2032-C0210P -29B 2032-C0210H -29B  
400A BS 88  
400A DIN 2032-C0210P -29D 2032-C0210H -29D  
400A BS 88 2032-C0300P -29B 2032-C0300H -29B  
2032-C0300P -29D 2032-C0300H -29D  
630A BS 88 2032-C0300P -30B 2032-C0300H -30B  
2032-C0300P -30D 2032-C0300H -30D  
400A DIN  
630A DIN  
400A BS88 2032-C0420P -29B 2032-C0420H -29B  
400A DIN 2032-C0420P -29D 2032-C0420H -29D  
420  
630  
132  
200  
220  
355  
300  
450  
2032-C0420P -30B 2032-C0420H -30B  
630A BS 88  
630A DIN 2032-C0420P -30D 2032-C0420H -30D  
500 630A BS 88 2032*-C0630P -30B 2032*-C0630H -30B  
Power fuses are not included with the disconnect switch. Select power fuses in accordance with applicable local codes.  
Optional Time Delay Feature. The Safety Isolation System may be ordered with a factory set time delay feature (30 seconds) in order to allow time for the machine operator  
to shut-down drives or other equipment that requires a controlled stop, after the operating handle on a Remote Lockout Station has been moved to the “Off” position. See  
next page for instructions on how to order the optional time delay feature. Consult your local Rockwell Automation sales office for other time settings.  
12-8  
Safety Isolation System  
ElectroGuard  
Combination Systems with Fusible Disconnect Switch  
Product Selection for Outside North America (see page 12-19 for Ordering Instructions)  
3-Phase Max. kW Rating  
(50Hz)  
Catalogue Num ber ➊  
IP 54 Motor Control  
Am pere  
Rating  
Fuse Clip  
Rating/  
Centre Type  
Enclosure (with  
bussing)  
(AC-3) 230V 400V 500V 600V Typ e ➊  
IP 30 Enclosure  
IP 54 Enclosure  
IP 65 Enclosure  
2032*-C0630W -30D  
2032*-C0630W -31B  
2032*-C0630W -31D  
2032*-C0860W -31B  
2032*-C0630P -30D 2032*-C0630H -30D  
2032*-C0630P -31B 2032*-C0630H -31B  
2032*-C0630P -31D 2032*-C0630H -31D  
2032*-C0860P -31B 2032*-C0860H -31B  
2032-!0630H 30D  
2032-!0630H -31B  
2032-!0630H -31D  
2032-!0860H -31B  
630A DIN  
630  
200  
355  
450  
500 800A BS 88  
1600A DIN  
800A BS 88  
1250A  
600  
860  
250  
391  
500  
710  
560  
2032*-C0860P -32B 2032*-C0860H -32B  
2032*-C0860P -31D 2032*-C0860H -31D  
2032*-C1200P -32B 2032*-C1200H -32B  
2032-!0860H -32B  
2032-!0860H -31D  
2032-!1200H -32B  
2032-!1200H -31D  
2032*-C0860W -32B  
2032*-C0860W -31D  
2032*-C1200W -32B  
2032*-C1200W -31D  
BS 88  
1600A DIN  
1250A  
BS 88  
1200  
888 1043  
1600A DIN 2032*-C1200P -31D 2032*-C1200H -31D  
To order the Tim e Delay feature, add the following Cat. String to the end of the Catalogue Num ber shown in the table:  
Factory set 30 second time delay feature:  
-1TD  
Example: Catalogue Number 2032-C0180P -29B becomes Catalogue Number 2032-C0180P -29B-1TD to include the time delay feature.  
* Input Power Feed Catalogue Num ber Code  
The Catalogue Number as listed is incomplete. Select an Input Power Feed Code from the table below.  
Example: Catalogue Number 2032*-C0630P -31B becomes Catalogue Number 2032T-C0630P -31B for a “Top Feed” input power requirement.  
Input Power Feed  
Catalogue Num ber Code  
Top Feed  
T
B
Bottom Feed  
! Bussing Designation  
The Catalogue Number as listed is incomplete. Select a Bussing Designation Code from the table below.  
Example: Catalogue Number 2032-!0085H -27D becomes Catalogue Number 2032-E0085H -27D for “600A Line Side Incoming Bus and Outgoing Power  
Cables” bussing designation.  
Ty p e o f B u s s i n g ➊  
Catalogue Num ber Code  
600A Line Side Incoming Bus and Outgoing Power Cables  
1200A Line Side Incoming Bus and Outgoing Power Cables  
Line Side Incoming Power Cables and 600A Load Side Outgoing Bus  
Line Side Incoming Power Cables and 1200A Load Side Outgoing Bus  
E
D
H
R
Input Line Voltage Code  
The Catalogue Number as listed is incomplete. Select an Input Line Voltage Code from the table below.  
Example: Catalogue Number 2032-C0085W -26B becomes Catalogue Number 2032-C0085WN-26B for a 380V 50Hz Input Line Voltage application.  
Input Line Voltage  
220V 50Hz  
A
380-400V 50Hz 400-415V 50Hz 440V 50Hz  
500V 50Hz  
M
550V 50Hz  
C
Voltage Code for Catalogue Number  
N
G
B
Product Selection: Remote Lockout Station ➊  
Catalogue Num ber  
IP 54 Enclosure  
2030-RLSHG  
“System Isolated” Light Colour  
Green  
IP 30 Enclosure  
2030-RLSPG  
IP 65 Enclosure  
2030-RLSW G  
Power fuses are not included with the disconnect switch. Select power fuses in accordance with applicable local codes.  
Optional Time Delay Feature. The Safety Isolation System may be ordered with a factory set time delay feature (30 seconds) in order to allow time for the machine operator  
to shut-down drives or other equipment that requires a controlled stop, after the operating handle on a Remote Lockout Station has been moved to the “Off” position.  
Consult your local Rockwell Automation sales office for other time settings.  
Bus Type: Copper with tin plating. Consult factory for other types of bussing.  
Safety Isolation Systems rated up through 85A can support a maximum of four (4) Remote Lockout Stations (RLS).  
Systems rated from 110A - 1200A can support a maximum of six (6) RLS. If additional RLS are required, order the optional Expansion Module(s) (see page 12-16).  
12-9  
Safety Isolation System  
ElectroGuard  
Combination Systems with Thermal-magnetic Circuit Breaker/Optional Features  
Product Selection for Outside of North America (see page 12-19 for Ordering Instructions)  
! Bussing Designation  
The Catalogue Number as listed is incomplete. Select a Bussing Designation Code from the table below.  
Example: Catalogue Number 2033-!0085H -44K becomes Catalogue Number 2033-E0085H -44K for “600A Line Side Incoming Bus and Outgoing Power  
Cables” bussing designation.  
Ty p e o f B u s s i n g ➊  
Catalogue Num ber Code  
600A Line Side Incoming Bus and Outgoing Power Cables  
1200A Line Side Incoming Bus and Outgoing Power Cables  
Line Side Incoming Power Cables and 600A Load Side Outgoing Bus  
Line Side Incoming Power Cables and 1200A Load Side Outgoing Bus  
E
D
H
R
Input Line Voltage Code  
The Catalogue Number as listed is incomplete. Select an Input Line Voltage Code from the table below.  
Example: Catalogue Number 2033-C0085W -48K becomes Catalogue Number 2033-C0085WN-48K for a 380V 50Hz Input Line Voltage application.  
Input Line Voltage  
220V 50Hz  
A
380-400V 50Hz  
N
400-415V 50Hz  
G
440V 50Hz  
B
500V 50Hz  
M
550V 50Hz  
C
Voltage Code for Catalogue Number  
Product Selection: Remote Lockout Station ➊  
Catalogue Num ber  
“System Isolated” Light Colour  
Green  
IP 30 Enclosure  
2030-RLSPG  
IP 54 Enclosure  
2030-RLSHG  
IP 65 Enclosure  
2030-RLSW G  
Optional Features  
Pneum atic Isolation Module (Must be ordered with Safety Isolation System ):  
The Safety Isolation System is available with an optional means of isolating the pneumatic energy source  
for the machine or process. If the machine operator/maintenance personnel initiates isolation of the  
electrical energy by operating one of the Remote Lockout Stations, a safety valve is simultaneously  
actuated to bleed pressure from the air line between the valve and the machine. When the air pressure has  
fallen to a predetermined level, the unit will allow the light on the Remote Lockout Station to illuminate,  
if electrical isolation has also been achieved.  
To order the Pneum atic Isolation option:  
Step 1: Add the following Catalogue String to the Safety Isolation System Catalogue Number:  
To indicate that the Safety Isolation  
System should be supplied as “Pneumatic  
Ready.”  
-1PN  
e.g. 2031-A0085JB-1PN to indicate an 85A Safety Isolation System that is to be “Pneumatic Ready.”  
Step 2: Order suitably enclosed Pneumatic Isolation Module as separate item:  
For North Am erica:  
Catalogue Num ber  
Pressure  
Range  
Valve Por t  
Size  
Type 1 General  
Purpose Enclosure  
Type 12 Dust tight  
Enclosure  
Type 4 W atertight  
Type 4X W atertight  
Painted Steel Enclosure Stainless Steel Enclosure  
1in  
2030-PA1201  
2030-PA1203  
2030-PJ1201  
2030-PJ1203  
2030-PF1201  
2030-PF1203  
2030-PC1201  
2030-PC1203  
30-120 psi  
3/4in  
For O utside of North Am erica:  
Catalogue Num ber  
IP 54 Enclosure  
2030-PH0071  
Pressure Range  
Valve Port Size  
IP 30 Enclosure  
2030-PP0071  
2030-PP0073  
IP 65 Enclosure  
2030-PW 0071  
2030-PW 0073  
1in  
2-7 bar  
3/4in  
2030-PH0073  
Bus Type: Copper with tin plating. Consult factory for other types of bussing.  
Safety Isolation Systems rated up through 85A can support a maximum of four (4) Remote Lockout Stations (RLS).  
Systems rated from 110A - 1200A can support a maximum of six (6) RLS. If additional RLS are required, order the optional Expansion Module(s) (see page 12-16).  
12-15  
Safety Isolation System  
ElectroGuard  
Optional Features (continued)  
Note: The time delay feature affects all input devices wired to the  
Expansion Module (Can be ordered separately):  
Expansion Module.  
For applications requiring more  
than the maximum allowable  
Remote Lockout Stations, or  
For Expansion Module(s) Factory Installed:  
Add One of the Following Catalogue Num ber Strings to  
the Safety Isolation System Catalogue Num ber:  
total wire lengths longer than  
those permitted with the  
Remote Lockout Stations.  
Num ber of Ports  
per Expansion  
Module  
Expansion Modules are  
Num ber of  
Expansion Modules  
Catalogue Num ber  
available in 4 or 10 port  
String ➊  
configurations. EachExpansion  
4
-1EUF  
-1EUFTDA  
-1EUT  
Module is wired to a port on the Control Module, and takes the  
connection port that would normally accommodate a Remote  
Lockout Station (see page 12-18 to determine if an Expansion  
Module is required due to wire length considerations).  
One (available on  
Bulletin 2031, 2032,  
or 2033, 110A–  
4 w/time delay  
10  
10 w/time delay  
4
1200A Systems only)  
-1EUTTDA  
-2EUF  
The 23A through 85A systems will accommodate connection of a  
maximum of 4 Expansion Modules, and the 110A through 1200A  
systems will accommodate connection of a maximum of 6  
Expansion Modules.  
Two (available on  
630A – 1200A  
Bulletin 2032 or 2033  
Systems only)  
4 w/time delay  
10  
-2EUFTDA  
-2EUT  
10 w/time delay  
-2EUTTDA  
Certain ampere size Safety Isolation System Power Panels can  
accommodate either 1 or 2 Expansion Modules installed internally.  
In all other instances the Expansion Module(s) must be located  
external to the Safety Isolation System in a suitably rated enclosure.  
e.g. Catalogue Number 2032T-A0630JB-30L becomes Catalogue Number  
2032T-A0630JB-30L-2EUT to indicate a 630A Safety Isolation System that  
includes 2 internally installed 10 port Expansion Modules without the time delay  
feature.  
Open Type Expansion Module for Field Addition  
Am pere Size of Safety Internal Provisions to Accom m odate  
Isolation System  
Expansion Modules  
O pen Type  
23A - 85A  
None  
Description  
Catalogue Num ber  
2030-EUNF  
Provisions to accept one (1) Expansion  
Module (Bulletins 2031, 2032 or 2033)  
4 port  
110A - 420A  
630A - 1200A  
4 port w/ time delay  
10 port  
2030-EUNF-1TDA  
2030-EUNT  
Provisions to accept up to two (2)  
Expansion Modules in Bulletin 2032 or 2033  
combination systems, or one (1) Expansion  
Module in Bulletin 2031 non combination  
systems.  
10 port w/time delay  
2030-EUNT-1TDA  
Requires user supplied enclosure if not installed in the Safety Isolation System  
Power Panel.  
Expansion Modules may be ordered with an adjustable time delay  
feature (1-30 seconds) in order to allow time for the machine  
operator to shut-down drives or other equipment that requires a  
controlled stop after a Remote Lockout Station has been switched to  
the “Offposition. Consult your Rockwell Automation sales office  
for other time settings.  
To order the Status Communication to a remote PLC option installed in an  
enclosed Expansion Module, add one of the following Catalogue Strings to the  
Expansion Module Catalogue Number:  
Com m unication  
Platform  
Num ber of I/O  
Points  
Catalogue  
Num ber String ➊  
Remote I/O  
DeviceNet  
16 points  
16 points  
-1CO M  
Enclosed Expansion Modules are available with optional “Flex”  
modules to provide status communication to a remote PLC.  
Communication can be via DeviceNet or Remote I/O.  
-1DNET  
e.g. Catalogue Number 2030-EUJF becomes Catalogue Number 2030-EUJF-  
1COM to indicate a Type 12 enclosed, 4-port expansion module, with 16 points  
of remote I/O.  
Note: The status communication option allows a remote PLC to receive  
status signals from the Expansion Module. The Expansion Module does  
not accept input signals from DeviceNet or Remote I/O.  
To order the optional enclosed Expansion Module for field addition for North Am erica:  
Catalogue Num ber ➊  
Description  
4 port  
Type 1 Enclosure  
2030-EUAF  
Type12 Enclosure  
2030-EUJF  
Type 4 Painted Enclosure  
2030-EUFF  
Type 4X Stainless Steel Enclosure  
2030-EUCF  
4 port w/ time delay  
10 port  
2030-EUAF-1TDA  
2030-EUAT  
2030-EUJF-1TDA  
2030-EUJT  
2030-EUFF-1TDA  
2030-EUFT  
2030-EUCF-1TDA  
2030-EUCT  
10 port w/time delay  
2030-EUAT-1TDA  
2030-EUJT-1TDA  
2030-EUFT-1TDA  
2030-EUCT-1TDA  
To order the optional enclosed Expansion Module for field addition for outside of North Am erica:  
Catalogue Num ber ➊  
Description  
IP30 Enclosure  
2030-EUPF  
IP54 Enclosure  
2030-EUHF  
IP65 Enclosure  
2030-EUW F  
4 port  
4 port w/ time delay  
10 port  
2030-EUPF-1TDA  
2030-EUPT  
2030-EUHF-1TDA  
2030-EUHT  
2030-EUW F-1TDA  
2030-EUW T  
10 port w/time delay  
2030-EUPT-1TDA  
2030-EUHT-1TDA  
2030-EUW T-1TDA  
12-16  
Safety Isolation System  
ElectroGuard  
Optional Features (continued)  
Status Com m unication to a rem ote PLC (Should be ordered with Safety Isolation System )  
This option provides Remote I/O via “Flex” modules. Communication can be via:  
The DeviceNet communication platform, or  
The Remote I/O communication platform.  
Note: The status communication option allows a remote PLC to receive status signals  
from the ElectroGuard Safety Isolation System. The ElectroGuard does not accept input  
signals through these communication platforms.  
Status communication capabilities:  
Overall system status,  
Status of each Remote Lockout Station,  
Status of the Pneumatic Isolation Module (if used),  
Status of other optional Safety Input devices.  
Note: Each communication module provides sixteen (16) data points. In determining which Catalogue Number String to specify from the table below,  
please keep the following in mind:  
Overall system status information requires one (1) data point.  
The Pneumatic Isolation Module (if used) requires one (1) data point.  
Each Remote Lockout Station used in the application requires one (1) data point.  
Each optional Rockwell Automation Safety Input device (i.e. Safety Mat, Light Curtain, E-Stop Station, Proximity Switch, Photo Switch)  
requires one (1) data point.  
To order the Status Com m unication to a rem ote PLC option, add one of the following Catalogue Strings to the Safety  
Isolation System Catalogue Num ber :  
Com m unication Platform  
Num ber of I/O points  
16 points  
Catalogue Num ber String ➊  
-1CO M  
32 points  
-2CO M  
Remote I/O  
48 points  
-3CO M"  
64 points  
-4CO M!  
16 points  
-1DNET  
32 points  
-2DNET  
DeviceNet  
48 points  
-3DNET"  
-4DNET!  
64 points  
" Maximum available for units from 23A through 85A.  
! Only available on units from 110A through 1200A.  
e.g. Catalogue Number 2031-A0085JB becomes Catalogue Number 2031-A0085JB-1CO M to indicate an 85A Safety Isolation System that includes 16 points of  
Remote I/O for status communication to a remote PLC.  
Cover Mounted Metering (Must be ordered with Safety Isolation System ):  
Cover mounted ammeters and/or voltmeters are available as factory installed options in order to provide visual indication of line side system  
current and/or voltage.  
To order m etering, add one or m ore of the following Catalogue Strings to the Safety Isolation System Catalogue  
Num ber :  
Type of Metering Required  
Single-phase Ammeter  
Catalogue Num ber String ➊  
-1AM  
-3AM  
-1VM  
-3VM  
Three-phase Ammeter  
Single-phase Voltmeter  
Three-phase Voltmeter  
e.g. Catalogue Number 2031-A0085JB becomes Catalogue Number 2031-A0085JB-1AM to indicate an 85A Safety Isolation System that includes a cover mounted  
single-phase Ammeter.  
12-17  
Safety Isolation System  
ElectroGuard  
Typical Wiring Diagram/Wire Length Considerations  
Total W ire Length for Expansion Modules  
Typical Wiring Diagram  
For North Am erica  
Max. Total  
For O utside North Am erica  
Safety Isolation System  
with Optional Fusible  
Disconnecting Means  
Max. Total  
W ire Length  
GC  
W ire Gauge  
W ire Length  
40,000 feet  
23,000 feet  
11,700 feet  
W ire Gauge  
14AWG  
18 Gauge Metric 12,200 meters  
14 Gauge Metric 7,000 meters  
16AWG  
18AWG  
Sample Calculation: An application for a 630A Safety Isolation  
System will require 8 Remote Lockout Stations (RLS):  
1IC 2IC  
L1  
T1  
To Motor  
Starters  
The wire length from RLS # 1 to the Control Module (in the  
ElectroGuard Power Panel) will be 50ft.  
L2  
L3  
T2  
T3  
To  
Loads  
The wire length from RLS # 2 to the Control Module will be 200ft.  
The wire length from RLS # 3 to the Control Module will be 100ft.  
The wire length from RLS # 4 to the Control Module will be 300ft.  
The wire length from RLS # 5 to the Control Module will be 500ft.  
The wire length from RLS # 6 to the Control Module will be 1000ft.  
The wire length from RLS # 7 to the Control Module will be 850ft.  
The wire length from RLS # 8 to the Control Module will be 750ft.  
Designates  
field  
connection  
points  
Remote  
Lockout  
Station(s)  
14AWG wire will be used to connect the RLS to the Control Module  
(see illustration below).  
Wire Length Considerations  
152m  
(500ft)  
304m  
(1000ft)  
259m  
(850ft)  
228m  
(750ft)  
ATTENTIO N: It is important not to  
exceed the maximum wire length values  
shown in this section. If the maximum values  
are exceeded, this may result in an unreliable  
signal to the Safety Isolation System.  
Consider using an Expansion Module if wire  
lengths greater than those shown for the  
Remote Lockout Stations are needed.  
RLS  
#5  
RLS  
#4  
RLS  
#8  
Expansion  
Module  
Each Remote Lockout Station is connected to the Control Module  
in the Power Panel of the Safety Isolation System. The total length  
of the wire used to connect the Remote Lockout Stations to the  
Control Module should not exceed the maximum values shown in  
the following tables.  
91m (300ft)  
30m (100ft)  
RLS  
#7  
RLS  
#3  
Control  
Module  
Calculate the total wire length as follows:  
RLS  
#6  
RLS  
#1  
61m (200ft)  
1. Determine the distance in feet or meters from each Remote  
Lockout Station to the Control Module (located inside the Safety  
Isolation System Power Panel).  
2. Sum the distances for all of the Remote Lockout Stations.  
3. Double this value.  
RLS  
#2  
Power Panel  
15m (50ft)  
4. Compare this doubled value with the maximum values for total  
wire length shown in the table below:  
Analysis: The Control Module furnished with the 630A Safety  
Isolation System is capable of supporting a maximum of six (6) RLS.  
Since this installation will require eight (8) RLS, an optional 4 port  
Expansion Module will also be used. The Expansion Module will be  
wired to the Control Module and will take the place of one of the  
original six RLS. We will, therefore, plan to wire five (5) of the RLS  
directly to the Control Module and three (3) of the RLS to the  
Expansion Module. Since the Expansion Module allows greater wire  
lengths than the Control Module, we will plan to wire the RLS to be  
installed furthest away from the Power Panel to the Expansion  
Module.  
Total W ire Length for Rem ote Lockout Stations  
For Nor th Am erica  
Max. Total  
For O utside of North Am erica  
Max. Total  
W ire Gauge  
18 Gauge Metric 1,400 meters  
14 Gauge Metric 800 meters  
W ire Gauge  
W ire Length  
W ire Length  
14AWG  
4,600 feet  
16AWG  
2,600 feet  
18AWG  
1,300 feet  
For RLS # 1: wire length = 50ft x 2 = 100ft  
For RLS # 2: wire length = 200ft x 2 = 400ft  
For RLS # 3: wire length = 100ft x 2 = 200ft  
For RLS # 4: wire length = 300ft x 2 = 600ft  
For RLS # 5: wire length = 500ft x 2 = 1000ft  
If the application requires a total wire length greater than those  
shown in the table, one or more Expansion Modules should be used.  
The maximum wire length for the Expansion Modules is shown in  
the following table:  
12-18  
Safety Isolation System  
ElectroGuard  
Wire Length Considerations/Ordering Instructions  
The total wire length for the 5 RLS to be wired to the Control  
Module will be: 100ft + 400ft + 200ft + 600ft + 1,000ft = 2,300ft  
b. Sum the full-load currents of all the motor loads to be  
connected to the Safety Isolation System. To this value add  
the current values of all resistive loads to be connected to  
the Safety Isolation System. This value is the “combined  
load full-load current.”  
c. Find the horsepower or kilowatt rating of a single motor with  
a full-load current value greater than or equal to the  
“combined load full-load current” value determined in Step  
“b”.  
Per the table entitled Total Wire Length for Remote Lockout Stations on  
page 12-18, the maximum allowable wire length for 14AWG wire is  
4,600ft for the RLS to be wired to the Control Module. This portion  
of the installation will be within the maximum wire length permitted.  
Next, we need to check the wire length calculation for the RLS to be  
wired to the Expansion Module.  
For RLS # 6: wire length = 1000ft x 2 = 200ft  
For RLS # 7: wire length = 850ft x 2 = 1700ft  
For RLS # 8: wire length = 750ft x 2 = 1500ft  
d. Select the Safety Isolation System that meets or exceeds this  
horsepower or kilowatt rating at the required voltage and  
frequency.  
e. Sum the locked-rotor currents of all the motor loads to be  
connected to the Safety Isolation System. To this value add  
the current values of all resistive loads to be connected to  
the Safety Isolation System. This value is the “combined  
load locked-rotor current”.  
f. Find the horsepower or kilowatt rating of a single motor with  
a locked-rotor current value greater than or equal to the  
“combined load locked-rotor current” value determined in  
Step “e”.  
The total wire length for the 3 RLS to be wired to the Expansion  
Module will be: 2000ft + 1700ft + 1500ft = 5,200ft  
Per the table entitled Total Wire Length for Expansion Modules on page  
12-18, the maximum allowable wire length for 14AWG wire is  
40,000ft for the RLS to be wired to the Expansion Module. This  
portion of the installation will also be within the maximum wire  
length permitted.  
Ordering Instructions  
g. Select the Safety Isolation System that meets or exceeds this  
horsepower or kilowatt rating at the required voltage and  
frequency.  
1. Determine the Catalogue Number of the Safety Isolation System  
based on the rating of the load(s) to which it will be connected as  
follows:  
h. Compare the ratings of the Safety Isolation Systems selected  
in Steps “d” and “g”. Select the larger of the two systems for  
your application.  
If the Safety Isolation System is connected to a single motor load,  
the horsepower or kilowatt rating of the system should be  
determined as follows:  
a. Select the Safety Isolation System that meets or exceeds the  
horsepower or kilowatt rating of the load at the required  
voltage and frequency.  
2. Determine how many Remote Lockout Stations are required for  
the application.  
3. Determine how many Expansion Modules (if any) are required  
for the application.  
4. Pick suitable enclosure type(s) for the Safety Isolation System  
Power Panel, Remote Lockout Stations and enclosed modules  
(e.g., Expansion Modules, Pneumatic Isolation Module).  
5. Determine what, if any, factory installed options are required for  
the application (e.g. Pneumatic Isolation, Status Communication  
to remote PLC, metering).  
If the Safety Isolation System is connected to two or more  
motors or one or more motors in combination with other loads,  
the horsepower or kilowatt rating of the system should be  
determined as follows:  
a. Identify the types of loads (i.e. motor, resistive) and the values  
of the currents of each of the loads (i.e. steady-state current  
for resistive loads, full-load and locked-rotor currents for  
motor loads) to be connected to the Safety Isolation System.  
12-19  

相关型号:

2032-C0085PX-27B

ElectroGuard
ALLEN-BRADLEY

2032-C0085PX-27D

ElectroGuard
ALLEN-BRADLEY

2032-C0085WX-26B

ElectroGuard
ALLEN-BRADLEY

2032-C0085WX-26D

ElectroGuard
ALLEN-BRADLEY

2032-C0085WX-27B

ElectroGuard
ALLEN-BRADLEY

2032-C0085WX-27D

ElectroGuard
ALLEN-BRADLEY

2032-C0110HX-26B

ElectroGuard
ALLEN-BRADLEY

2032-C0110HX-26D

ElectroGuard
ALLEN-BRADLEY

2032-C0110HX-27B

ElectroGuard
ALLEN-BRADLEY

2032-C0110HX-27D

ElectroGuard
ALLEN-BRADLEY

2032-C0110HX-28D

ElectroGuard
ALLEN-BRADLEY

2032-C0110PX-26B

ElectroGuard
ALLEN-BRADLEY