AMEL12-5SCJZ [AIMTEC]
Continuous Short Circuit Protection;型号: | AMEL12-5SCJZ |
厂家: | AIMTEC |
描述: | Continuous Short Circuit Protection |
文件: | 总3页 (文件大小:149K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Click on Series name for product info on aimtec.com
Series AMEL12-CJZ
12 Watt | AC-DC / DC-DC Converter
Picture coming soon
FEATURES:
• I/O Isolation 4000VAC
•
•
•
•
Low no load consumption ≤0.3W
Continuous Short Circuit Protection
Up to 83% efficiency
• Operating Temp: -25°C to +70°C
• Over current, Over Voltage
•
Input: 85-264VAC, 47-440Hz, or 100-370VDC
Low ripple and noise
Models
Single output
Maximum
capacitive
load
Max
Input
Voltage
(VDC)
Output
Voltage
(V)
Output
Current
max (A)
Input Voltage
Efficiency
Output
wattage
(W)
Model
(VAC/Hz)
(%)
(µF)
AMEL12-3.3SCJZ
AMEL12-5SCJZ
AMEL12-15SCJZ
AMEL12-24SCJZ
85-264/47-440
85-264/47-440
85-264/47-440
85-264/47-440
100-370
100-370
100-370
100-370
7.9
12
12
12
3.3
5
15
24
2.4
2.4
0.8
0.5
10,000
10,000
2,700
74
78
82
83
1,500
*Output power must not exceed the listed values.
All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless
otherwise specified.
Input Specifications
Parameters
Conditions
115VAC
230VAC
115VAC
230VAC
Typical
0.28
0.19
10
Maximum
Units
A
A
A
A
Current
Inrush current <2ms (cold start)
20
Leakage current
External fuse
Input dissipation
0.25
mA
A
W
slow blow type
No Load
3.15
≤0.3
Output Specifications
Parameters
Conditions
3.3V output
Others
Typical
±3
Maximum
Units
Voltage accuracy
%
±2
Line regulation
Load regulation
Ripple & Noise
Full load
±0.5
±1
%
%
mV p-p
ms
10-100% load
20MHz bandwidth
115VAC
100
24
120
Hold up time
230VAC
ms
Isolation Specifications
Parameters
Tested I/O voltage
Conditions
Typical
Rated
4000
Units
VAC
MΩ
60 sec
Isolation resistance
>1000
General Specifications
Parameters
Conditions
Typical
Maximum
Units
Switching frequency
Protection class
Over current protection
Over voltage protection
Short circuit protection
Short circuit restart
100% load
100
Class II
≥110
KHz
Auto recovery
% of Iout
Zener Diode Clamp
Continuous
Auto recovery
-25 to +70
Operating temperature
Maximum case temperature
See derating table
oC
oC
100
www.aimtec.com
F 052e R8
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL12-CJZ
12 Watt | AC-DC / DC-DC Converter
General Specifications (continued)
Parameters
Storage temperature
Temperature coefficient
Cooling
Conditions
Typical
-25 to +105
±0.02
Free air convection
Maximum
Units
oC
% / oC
Humidity
Case material
Weight
Non condensing
95
% RH
g
Heat resistant black Plastic (flammability to UL 94V-0)
60
Dimensions (L x W x H)
MTBF
2.12 x 1.13 x 0.93 inches
53.80 x 28.80 x 23.50 mm
> 300 000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load
Safety Specifications
Parameters
Agency approvals
cULus, CE pending
Information technology Equipment
EMI - Conducted and radiated emission
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
Meets IEC/EN/UL 60950-1
EN55022, class B
IEC 61000-4-2 Level 3
IEC 61000-4-3 Level 3
IEC 61000-4-4 Level 4
IEC 61000-4-5 Level 3
IEC 61000-4-6 Level 3
IEC 61000-4-8 Level 3
IEC 61000-4-11 Class 2
Standards
Pin Out Specifications
Dimensions
Pin
Single
53.80
(2.12)
Case Temperature
Measurement point
1
2
3
4
AC Input (N)
AC Input (L)
+V Output
45.72
(1.80)
1
2
3
4
1
3
TOP VIEW
10.16
(0.40)
-V Output
28.80
(1.13)
20.32
(0.80)
TOP VIEW
+
4
5
2
23.50
(0.93)
DIV: 5.08 (0.2)
Ø 1.5 (Ø 0.06)
Dimensions mm (inch)
Case Tolerance ±0.50 (±0.02)
Ø 1.00
(0.04)
Pin Diameter 1.0 ± 0.10 (0.04 ± 0.004)
Pin Pitch Tolerance ±0.35 (±0.014)
www.aimtec.com
F 052e R8
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL12-CJZ
12 Watt | AC-DC / DC-DC Converter
Derating
Free Air Convection at 25°C
Free Air Convection
100
100
80
80
70
75
Safe Operating Area
Input 100-240VAC or
120-340VDC
Safe Operating Area
60
60
50
40
20
40
20
0
0
70
0
20
40
5560
80
º C
85
100
240
264
- 25
-
20
100
(100) (120)
(340)
(370)
Ambient Temperature
Input Voltage VAC (VDC)
Typical application circuit
Single Output
FUSE
NTC
1A/300V
4
3
+ Vout
AC L
AC L
+
MOV
S20K350
AC
DC
C1
1µF/50V
C2
TVS
AC N
AC N
- Vout
Model
C2
TVS
7V
20V
30V
3.3 & 5 Vout
12 & 15 Vout
24 Vout
220 µF / 10V
120 µF / 25V
68 µF / 35V
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
相关型号:
©2020 ICPDF网 联系我们和版权申明