AMEL10-5SMJZ [AIMTEC]

AC/DC Converter; Product Weight (grams): 50; Input voltage min (V): 85; Input voltage max (V): 264; Input frequency (Hz): 47-440; Output voltage min: 5; Output voltage max: 5; Output voltage dual assymetric (y/n): Single; Output Power (W): 10; Max Output current (A): 2; Efficiency (%): 76; Max Capacitive load (µF): 12000; Package type: Encapsulated; Mounting: PCB; W (in): 1.13; L (in): 2.12; H (in): 0.75; W (mm): 28.8; L (mm): 53.8; H (mm): 19; Min Operating temperature: -25; Max operating temperature (°C): 70; Isolation (VAC): 4000; EMC compliance 1: EN 55011 Class A; Case material: Plastic;
AMEL10-5SMJZ
型号: AMEL10-5SMJZ
厂家: AIMTEC    AIMTEC
描述:

AC/DC Converter; Product Weight (grams): 50; Input voltage min (V): 85; Input voltage max (V): 264; Input frequency (Hz): 47-440; Output voltage min: 5; Output voltage max: 5; Output voltage dual assymetric (y/n): Single; Output Power (W): 10; Max Output current (A): 2; Efficiency (%): 76; Max Capacitive load (µF): 12000; Package type: Encapsulated; Mounting: PCB; W (in): 1.13; L (in): 2.12; H (in): 0.75; W (mm): 28.8; L (mm): 53.8; H (mm): 19; Min Operating temperature: -25; Max operating temperature (°C): 70; Isolation (VAC): 4000; EMC compliance 1: EN 55011 Class A; Case material: Plastic

PC 光电二极管
文件: 总3页 (文件大小:266K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Click on Series name for product info on aimtec.com  
Series AMEL10-MJZ  
10 Watt | AC-DC / DC-DC Converter  
FEATURES:  
I/O Isolation 4000VAC  
Low no load consumption ≤0.5W  
Continuous Short Circuit Protection  
Up to 83% efficiency  
Operating Temp: -25°C to +70°C  
Over current, Over Voltage  
Input: 85-264VAC, 47-440Hz, or 100-370VDC  
Models  
Single output  
Maximum  
capacitive  
load  
Input  
Voltage  
(VDC)  
Output  
Voltage  
(V)  
Output  
Current max  
(A)  
Max Output  
wattage  
(W)  
Input Voltage  
Efficiency  
Model  
(VAC/Hz)  
(%)  
(µF)  
AMEL10-3.3SMJZ  
AMEL10-5SMJZ  
AMEL10-9SMJZ  
AMEL10-12SMJZ  
AMEL10-15SMJZ  
AMEL10-24SMJZ  
85-264/47-440  
85-264/47-440  
85-264/47-440  
85-264/47-440  
85-264/47-440  
85-264/47-440  
100-370  
100-370  
100-370  
100-370  
100-370  
100-370  
6.6  
10  
10  
10  
10  
10  
3.3  
5
9
12  
15  
24  
2.00  
2.00  
1.10  
0.90  
0.70  
0.45  
15,000  
12,000  
6,000  
2,000  
1,500  
71  
76  
80  
81  
82  
83  
500  
*Output power must not exceed the listed values.  
All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless  
otherwise specified.  
Input Specifications  
Parameters  
Conditions  
115VAC  
230VAC  
Typical  
0.23  
0.15  
Maximum  
Units  
A
A
Current  
115VAC  
230VAC  
10  
20  
A
A
Inrush current <2ms (cold start)  
Leakage current  
External fuse  
Input dissipation  
0.25  
mA  
A
W
slow blow type  
No Load  
2
0.5  
Output Specifications  
Parameters  
Conditions  
3.3V output  
Others  
Typical  
±3  
Maximum  
Units  
Voltage accuracy  
%
±2  
Line regulation  
Load regulation  
Ripple & Noise  
Hold up time  
Full load  
±0.5  
±1  
50  
%
%
mV p-p  
ms  
10-100% load  
20MHz bandwidth  
230VAC  
100  
80  
Isolation Specifications  
Parameters  
Tested I/O voltage  
Isolation resistance  
Conditions  
Typical  
Rated  
4000  
Units  
VAC  
MΩ  
60 sec  
>1000  
General Specifications  
Parameters  
Switching frequency  
Protection class  
Over current protection  
Over voltage protection  
Short circuit protection  
Short circuit restart  
Conditions  
100% load  
Typical  
Maximum  
Units  
KHz  
65  
Class II  
110 - 200  
Auto recovery  
% of Iout  
Zener Diode Clamp  
Continuous  
Auto recovery  
-25 to +70  
Operating temperature  
See derating table  
oC  
www.aimtec.com  
F 052e R8.B  
REV: 02/20/A  
Tel: +1 514 620 2722  
1 of 3  
Toll free: + 1 888 9 AIMTEC (924 6832)  
North America only  
Series AMEL10-MJZ  
10 Watt | AC-DC / DC-DC Converter  
General Specifications (continued)  
Parameters  
Maximum case temperature  
Storage temperature  
Temperature coefficient  
Cooling  
Conditions  
Typical  
Maximum  
Units  
oC  
100  
-25 to +105  
±0.02  
Free air convection  
oC  
% / oC  
Humidity  
Case material  
Weight  
Dimensions (L x W x H)  
MTBF  
Non condensing  
95  
% RH  
g
Heat resistant black Plastic (flammability to UL 94V-0)  
PCB mountable models  
PCB mountable models  
50  
2.11 x 1.13 x 0.748 inches (53.80 x 28.80 x 19.00mm)  
> 300 000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load  
Safety Specifications  
Parameters  
Agency approvals  
cULus, CE  
Medical Electrical Equipment  
Meets IEC/EN/UL 60601-1, 2 x MOPP  
IEC/EN/UL 60950-1  
EN55011, class A  
IEC 61000-4-2 Level 3  
IEC 61000-4-3 Level 3  
IEC 61000-4-4 Level 3  
IEC 61000-4-5 Level 2, with application circuit  
IEC 61000-4-6 Level 3  
IEC 61000-4-8 Level 3  
IEC 61000-4-11 Class 2  
Information technology Equipment  
EMI - Conducted and radiated emission  
Electrostatic Discharge Immunity  
RF, Electromagnetic Field Immunity  
Electrical Fast Transient/Burst Immunity  
Surge Immunity  
RF, Conducted Disturbance Immunity  
Power frequency Magnetic Field Immunity  
Voltage dips, Short Interruptions Immunity  
Standards  
Pin Out Specifications  
Dimensions  
Pin  
1
2
3
Single  
AC Input (N)  
AC Input (L)  
+V Output  
-V Output  
53.80  
(2.12)  
Case Temperature  
Measurement point  
45.72  
(1.80)  
1
2
3
4
1
2
3
TOP VIEW  
+
10.16  
(0.40)  
4
28.80  
(1.13)  
20.32  
(0.80)  
TOP VIEW  
4
5
19.00  
(0.75)  
DIV: 5.08 (0.2)  
Ø 1.5 (Ø 0.06)  
Dimensions mm (inch)  
Case Tolerance ±0.50 (±0.02)  
Ø 1.00  
(0.04)  
Pin Diameter 1.0 ± 0.10 (0.04 ± 0.004)  
Pin Pitch Tolerance ±0.35 (±0.014)  
www.aimtec.com  
F 052e R8.B  
REV: 02/20/A  
Tel: +1 514 620 2722  
2 of 3  
Toll free: + 1 888 9 AIMTEC (924 6832)  
North America only  
Series AMEL10-MJZ  
10 Watt | AC-DC / DC-DC Converter  
Derating  
Free Air Convection at 25°C  
Free Air Convection  
100  
100  
80  
80  
70  
Safe Operating Area  
Input 110-240VAC or  
140-340VDC  
Safe Operating Area  
60  
60  
40  
50  
40  
20  
0
20  
0
70  
0
20  
40  
5560  
80  
º C  
85  
100  
240  
264  
- 25  
-10  
-
20  
100  
(100) (140)  
(340)  
(270)  
Ambient Temperature  
Input Voltage VAC (VDC)  
Typical application circuit  
Single Output  
FUSE  
2A/250V  
4
3
+ Vout  
AC L  
AC L  
TVS  
+
MOV  
S14K350  
AC  
DC  
C1  
1µF/50V  
C2  
AC N  
AC N  
- Vout  
Class B compliance recommended circuit  
Single Output  
R1  
12 /3W  
LCM  
2.2mH  
LDM  
4.7µH/2A  
FUSE  
2A/250V  
+Vout  
+Vout  
- Vout  
AC L  
AC N  
CY1  
1nF/  
400VAC  
TVS  
+
CX  
0.1µF/  
275VAC  
C2  
1µF/50V  
MOV  
S14K350  
AC  
DC  
C1  
CY2  
1nF/  
400VAC  
AC N  
GND  
AC L  
- Vout  
R2  
12 /3W  
Model  
C2  
TVS  
3.3 & 5 Vout  
9Vout  
12 & 15 Vout  
24 Vout  
220 µF / 10V  
120 µF / 25V  
120 µF / 25V  
68 µF / 35V  
7V  
12V  
20V  
30V  
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled  
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the  
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,  
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components  
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This  
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate  
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.  
www.aimtec.com  
F 052e R8.B  
REV: 02/20/A  
Tel: +1 514 620 2722  
3 of 3  
Toll free: + 1 888 9 AIMTEC (924 6832)  
North America only  

相关型号:

AMEL10-9CSJZ

AC-DC / DC-DC Converter
AIMTEC

AMEL10-9SMJZ

AC/DC Converter; Product Weight (grams): 50; Input voltage min (V): 85; Input voltage max (V): 264; Input frequency (Hz): 47-440; Output voltage min: 9; Output voltage max: 9; Output voltage dual assymetric (y/n): Single; Output Power (W): 10; Max Output current (A): 1.1; Efficiency (%): 80; Max Capacitive load (µF): 6000; Package type: Encapsulated; Mounting: PCB; W (in): 1.13; L (in): 2.12; H (in): 0.75; W (mm): 28.8; L (mm): 53.8; H (mm): 19; Min Operating temperature: -25; Max operating temperature (°C): 70; Isolation (VAC): 4000; EMC compliance 1: EN 55011 Class A; Case material: Plastic
AIMTEC

AMEL10-AZ

10 Watt | AC-DC Converter
AIMTEC

AMEL10-AZ_13

10 Watt | AC-DC / DC-DC Converter
AIMTEC

AMEL10-CJZ

AC-DC / DC-DC Converter
AIMTEC

AMEL10-MAZ

10 Watt | AC-DC Converter
AIMTEC

AMEL10-MAZ_12

10 Watt | AC-DC / DC-DC Converter
AIMTEC

AMEL10-MAZ_13

10 Watt | AC-DC / DC-DC Converter
AIMTEC

AMEL10-MJZ

Continuous Short Circuit Protection
AIMTEC

AMEL12-15SCJZ

Continuous Short Circuit Protection
AIMTEC

AMEL12-24SCJZ

Continuous Short Circuit Protection
AIMTEC

AMEL12-3.3SCJZ

Continuous Short Circuit Protection
AIMTEC