AME1-12SBAZ [AIMTEC]
1Watt | AC-DC Converter;型号: | AME1-12SBAZ |
厂家: | AIMTEC |
描述: | 1Watt | AC-DC Converter |
文件: | 总3页 (文件大小:163K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Click on Series name for product info on aimtec.com
Series AME1-AZ
1Watt | AC-DC Converter
FEATURES:
I/O Isolation 3000VAC
RoHS compliant
Energy Star compliant
Operating Temp: -40°C to +80°C
Input: 90-305VAC, 47-440Hz, or 130-430 VDC
Optional 90-528VAC, 47-440Hz, or 130-745 VDC
Over load, Short Circuit Protection
Ultra small package
Mo
Single output
Maximum
capacitive
Efficiency
(%)
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Temperature
range
Output
Voltage
(V)
Output
Current max
(mA)
Model
Load
(µF)
115
230
277
480
(ºC)
VAC
VAC
VAC
VAC
AME1-3.3SAZ
AME1-5SAZ
AME1-12SAZ
AME1-15SAZ
AME1-24SAZ
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
130-430
130-430
130-430
130-430
130-430
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
3.3
5
12
15
24
300
200
83
67
42
2200
1100
680
560
470
62
58
73
77
79
59
57
68
68
79
58
56
65
70
77
AME1-3.3SBAZ
AME1-5SBAZ
AME1-12SBAZ
AME1-15SBAZ
AME1-24SBAZ
90-528/47-440
90-528/47-440
90-528/47-440
90-528/47-440
90-528/47-440
130-745
130-745
130-745
130-745
130-745
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
3.3
5
12
15
24
300
200
83
67
42
2200
1100
680
560
470
51
57
62
61
58
51
57
62
59
58
50
56
60
58
56
44
50
51
50
48
Input Specifications
Parameters
Conditions
115 VAC
230 VAC
277 VAC
480VAC
Typical
Maximum
Units
mA
mA
mA
mA
A
A
A
A
25
20
15
5
10
15
20
30
Current (full load)
115 VAC
230 VAC
277 VAC
480 VAC
Inrush current <2ms (cold start)
Leakage current
External fuse
0.15
mA
A
1
Recommended slow blow type
Input Dissipation (No Load)
W
≦0.3
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation (single output)
Transient Recovery Time
Transient Response Deviation
Minimum load
Conditions
Full load (typical)*
LL-HL, Full Load
Typical
±5
±1.5
±5
Maximum
Units
%
%
%
µs
0-100% load (typical)*
200
±2
0
25% load step
% of Vout
%
3.3/5 VDC With 560µF E/C
12/15 VDC With 220µF E/C
24 VDC With 220µF E/C
200
400
500
mV p-p
mV p-p
mV p-p
Ripple & Noise
*Ripple &Noise measured at 20MHz bandwidth with 0.1µF and 115/230/277/480 VAC (Typical input) with Full Load.
Isolation Specifications
Parameters
Conditions
Typical
Rated
3000
Units
VAC
MΩ
Tested I/O voltage
60 sec
Isolation Resistance
>1000
www.aimtec.com
F 052e R8.H
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AME1-AZ
1Watt | AC-DC Converter
General Specifications
Parameters
Switching frequency
Over Load protection
Short circuit protection
Operating temperature
Storage temperature
Maximum Case temperature
Humidity
Conditions
Auto recovery
Typical
100
>125%
Maximum
Units
KHz
Auto recovery
Without derating
-40 to +80
-40 to +85
oC
oC
oC
100
Non condensing
20 ~ 95
% RH
Case material
Plastic resin + Fiberglass (flammability to UL 94V-0)
Weight
25
g
Dimensions (L x W x H)
1.40 x 0.92 x 0.76 (35.60 x 23.31 x 19.32mm)
> 400,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load
> 100,000 hrs (MIL-HDBK -217F, t= at highest operating temperature)/Full Load
MTBF
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load
unless otherwise specified.
Environment Approval
Parameters
Conditions
Wave form: Half sine wave
Acceleration amplitude: 5gn
Shock
Bump duration: 30 ms
Number of bumps: 18 (3 in each direction for every axis)
Converter operation before and after test, body mounted (on chassis)
Test mode: Sweep sine
10-100Hz, speed 0.05Hz/s
Displacement: 1mm
Vibrations
Acceleration: 3g
3 loops 30min one cycle, 3h total, every axis tested
Converter operation before and after test, body mounted (on chassis)
Safety Specifications
Parameters
Agency approvals
cULus, CE, CB, FCC
Information technology Equipment
EMI - Conducted and radiated emission
Harmonic Current Emissions
IEC/EN/UL 60950-1:2006+A11:2009
EN55022, class B (* see note)
IEC/EN 61000-3-2, Class A
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5(SAZ:Level2,SBAZ:Level 1)
IEC 61000-4-6
IEC 61000-4-8
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity(1KV)
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
FCC part 15 Subpart B, Class B, ANSI C63.4 :2003
Standards
IEC 61000-4-11
* Note: for 528VAC models to meet the EN55022 class B spec an external 0.33uF X capacitor is needed to be installed between AC L and AC N as close
as possible to the input of the power supply itself
Pin Out Specifications*
Pin
Single
AC Input (N) or (L1)
AC Input (L) or (L2)
-V Output
1*
2*
3
4
+V Output
* Note: Input Pins 1 and 2 can be “N” and "L" respectively when the input voltage is supplied from a single phase.
Input Pins 1 and 2 can be “L1” and "L2" respectively when the input voltage is supplied from 3 phase line to line voltage 208-480Vac (208 Y/ 120V 3-phase,
240 Y/ 120V 3-phase, 400 Y/ 230V 3-phase or 480 Y/ 277V 3-phase).
www.aimtec.com
F 052e R8.H
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AME1-AZ
1Watt | AC-DC Converter
Dimensions
(0.65)
35.60
(1.40)
Top View
1
3
4
11.655
(0.46)
1
3
4
Temperaturem
easuringpoint
7.60
23.31
(0.92)
(0.29)
15.24
(0.60)
Top View
2
2
28.00
(1.10)
DIV: 5.00(0.20)
Ø 10.0 ( Ø 0.40)
Ø 0.60 ( Ø 0.02)
19.32
(0.76)
Side View
Dimensions mm (inch)
Case Tolerance ±0.50 (±0.02)
Pin Diameter ±0.05(±0.002)
Pin Pitch Tolerance ±0.50(±0.02)
6.00
(0.24)
0.60
(0.02)
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3.Mechanical drawings and specifications are for reference only. 4.All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8.H
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
相关型号: