AM60EW-4812DZ [AIMTEC]
DC-DC Converter;型号: | AM60EW-4812DZ |
厂家: | AIMTEC |
描述: | DC-DC Converter |
文件: | 总5页 (文件大小:472K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Click on Series name for product info on aimtec.com
Series AM60EW-Z
60 Watt | DC-DC Converter
Picture coming soon
FEATURES:
• Wide Input 4:1 Range
• No Minimum Load Required
• Soft Start
• Efficiency up to 93%
• 1600 VDC Isolation
• Adjustable Output Voltage
• Remote ON/OFF Function
• Operating temperature -40°C to + 75°C
• Over Current, Over Voltage, Over Temperature &
Continuous Short Circuit Protection
Models
Single output
Input Current
Output
No load/Full
Voltage
load
Input
Voltage
(V)
Output
Current max
(A)
Max Capacitive
load (µF)
Efficiency
(%)
Model
(V)
(mA)
AM60EW-2405SZ
AM60EW-2412SZ
AM60EW-2415SZ
AM60EW-4805SZ
AM60EW-4812SZ
AM60EW-4815SZ
9-36
9-36
9-36
18-75
18-75
18-75
25/2703
25/2703
25/2688
25/1344
25/1351
25/1344
5
12
5
4
12
5
4
30,000
5850
3900
30,000
5850
3900
93
93
93
93
93
93
12
15
5
12
15
Models
Dual output
Input Current
No load/Full
load
Input
Voltage
(V)
Output
Voltage
(V)
Output
Current max
(A)
Max Capacitive
load (µF)
Efficiency
(%)
Model
(mA)
AM60EW-2412DZ
AM60EW-2415DZ
AM60EW-4812DZ
AM60EW-4815DZ
9-36
9-36
18-75
18-75
40/2747
50/2747
40/1373
50/1373
±12
±15
±12
±15
±2.5
±2
±2.5
±2
±3900
±2400
±3900
±2400
91
91
91
91
Add suffix “-K” for optional heatsink
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Nominal
Typical
9-36
18-75
Maximum
Units
24
48
Voltage range
VDC
Filter
π(Pi) Network
Start up time
60
ms
24
48
50
100
100
Absolute Maximum Rating
VDC
Peak Input Voltage time
ms
Input reflected ripple current
Measured with the referenced circuit
(24V model)
20
8.6/7.9
17.8/16
mA p-p
Under Voltage Lockout (On/Off)
Remote On / OFF Control
VDC
VDC
(48V model)
ON: 3 ~12Vdc or Open Circuit
OFF: 0 ~ 1.2Vdc or Short pin 2 & 3 (idle current 5mA typical)
Isolation Specifications
Parameters
Tested I/O voltage
Case Input & Output
Resistance
Conditions
Typical
Rated
1600
1600
Units
VDC
VDC
MOhm
pF
60s
60s
>1000
2200
Capacitance
www.aimtec.com
F 051e R12.C
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AM60EW-Z
60 Watt | DC-DC Converter
Output Specifications
Parameters
Conditions
Hiccup
Typical
Maximum
Units
%
Voltage accuracy
±1
Over voltage protection
Over load protection
Short Circuit protection
Short circuit restart
Zener Diode Clamp
120%~140%
Indefinite
Thermal shutdown
On Case
120
ºC
Line voltage regulation
±0.5
% of Vin
0% to 100% Full Load, Single
Dual Output
±0.5
±1
Load voltage regulation
%
Temperature coefficient
Ripple & Noise
Transient Response Deviation
Transient Recovery
±0.02
%/oC
mV p-p
% of Max
µsec
20MHz Bandwidth
100
±3
250
±10
Voltage adjustment range
%
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
Conditions
100% load
With derating (see graph below)
Typical
225
Maximum
Units
KHz
oC
-40 to +75
-55 to +125
oC
110
95
oC
Free Air Convection
Humidity
Case material
Weight
% RH
g
Non-conductive Black Plastic (UL94V-0 rated)
45
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
2.00 x 1.00 x 0.45 inches
>210 000 hrs (MIL-HDBK-217 F at +25 oC)
1.5mm from case for 10 sec 260
50.8 x 25.4 x 11.43 mm
oC
Safety Specifications
Parameters
Agency approvals
CE, UL (pending)
EMI - Conducted and radiated emission EN55022, class A (with the recommended EMI circuit), EN55024: 2010
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
IEC 61000-4-2, Criteria A
IEC 61000-4-3, Criteria A
Electrical Fast Transient/Burst Immunity IEC 61000-4-4, Criteria A, (with the recommended EMC circuit)
Standards
Surge Immunity
IEC 61000-4-5, Criteria A, (with the recommended EMC circuit)
IEC 61000-4-6, Criteria A
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field
Immunity
IEC 61000-4-8, Criteria A
Pin Out Specifications
Single
+V Input
-V Input
Dual
Pin
1
+V Input
2
-V Input
3
4
5
6
On/Off Control
+V Output
-V Output
Trim
On/Off Control
+V Output
Common
-V Output
www.aimtec.com
F 051e R12.C
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AM60EW-Z
60 Watt | DC-DC Converter
Dimensions
50.80
(2.00)
5.08
(0.20)
4
5
6
1
2
Bottom View
3
2.54
2.54
(0.10)
(0.10)
Notes:
All dimensions are typical in millimeters (inches).
Pin Pitch and Length Tolerance: ±0.35 (±0.014)
Pin Diameter: ±0.05 (±0.002)
Case Tolerance ±0.50 (±0.02)
Stand-off Tolerance: ±0.10 (±0.004)
ᴓ1.00
(0.04)
Dimensions with Optional Heatsink
50.8
(2.0)
25.4
(1.0)
17.6
(0.69)
SIDE
END
Notes: Add “-K” suffix for ordering, heatsink is affixed with thermally dissipative adhesive tape.
See derating graph for temperature performance. Heatsink material is anodized (black) aluminum, adds weight 11g to total
mass (56g). Thermal impedance of converter is: without heatsink 9.5°C/W and 8.5°C/W with heatsink.
Derating
AM60EW-2405SZ
Others
Free Air Convection
Free Air Convection
º
C without heat sink
45
º
C without heat sink
50
100
80
100
80
º
C with heat sink
52
º
C with heat sink
57
Safe Operating Area
Safe Operating Area
60
50
40
60
50
40
20
0
20
0
45 52
40 60
75
80
50 57
40 60
75
80
100
- 40 - 20
0
20
100
- 40 - 20
0
20
º C
º C
Ambient Temperature
Ambient Temperature
www.aimtec.com
F 051e R12.C
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AM60EW-Z
60 Watt | DC-DC Converter
Extended temperature performance can be achieved with optional heatsink. (add suffix “–K” to part number).
Trimming
Leave open if not used.
AM60EW-xx05SZ
Trim down %
Vout (VDC)
Rt down (KΩ)
Trim up %
1
4.95
151.46 133.91
1
5.05
256.85
2
4.9
3
4.85
83.26
3
5.15
23.95
4
4.8
5
4.75
6
4.7
7
4.65
8
4.6
9
4.55
10
4.5
59.01 44.79
35.44 28.82 23.89 20.08 17.04
2
5.1
37.9
4
5.2
5
5.25
6
5.3
9.27
7
5.35
7.11
8
5.4
5.48
9
5.45
4.21
10
5.5
3.18
Vout (VDC)
Rt up (KΩ)
16.71 12.27
AM60EW-xx12SZ
Trim down %
1
2
3
4
5
6
7
8
9
10
10.8
69.83 57.73 48.31 40.76
Vout (VDC)
Rt down (KΩ)
Trim up %
11.88
11.76
11.64
11.52
11.4 11.28
11.16 11.04 10.92
638.7 309.72 198.29 142.24 108.49 85.95
1
12.12
2
12.24
97.18
3
12.36
58.4
4
12.48
39.13
5
6
7
8
9
10
13.2
4.65
Vout (VDC)
12.6 12.72
27.61 19.94
12.84 12.96 13.08
14.48 10.38 7.2
Rt up (KΩ)
215.45
AM60EW-xx15SZ
Trim down %
1
2
14.7
3
4
14.4
5
6
14.1
7
8
9
10
13.5
Vout (VDC)
Rt down (KΩ)
Trim up %
14.85
14.55
14.25
13.95
13.8 13.65
842.92 431.72 283.82 207.67 161.24 129.97 107.49 90.54 77.31 66.69
1
15.15
2
15.3
3
15.45
58.51
4
15.6
5
15.75
27.05
6
15.9
7
16.05
13.89
8
9
10
16.5
4.14
Vout (VDC)
16.2 16.35
9.82 6.66
Rt up (KΩ)
233.53
99.39
38.73
19.35
www.aimtec.com
F 051e R12.C
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AM60EW-Z
60 Watt | DC-DC Converter
EMI recommended circuit
Single output models
Dual output models
C3
C3
C4
C4
L1
+V output
+V output
Common
+V input
+V input
DC/DC
Converter
Load
Load
DC/DC
Converter
Load
C1
C2
C1
C2
L2
-V input
-V output
-V input
-V output
C5
Vin single output
C1, C2
4.7 µF / 50V
1.5 µF / 100V
L1, L2
C3
C4, C5
24V
48V
12 µH
470 pF / 2KV 1 nF / 2KV
Vin dual output
C1, C2
4.7 µF / 50V
1.5 µF / 100V
C3
C4
24V
48V
220 pF / 2KV 1.5 nF / 2KV
EFT/Surge Circuit recommendation
+Vout
+Vin
Vin
24V
48V
C1
D1
DC/DC
Converter
TVS 58V, 3KW
TVS 120V, 3KW
330 µF / 100V
Load
C1
-Vin
-Vout
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.C
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
相关型号:
©2020 ICPDF网 联系我们和版权申明