AM40U-2412SAZ [AIMTEC]
40 Watt | DC-DC Converter; 40瓦| DC- DC转换器型号: | AM40U-2412SAZ |
厂家: | AIMTEC |
描述: | 40 Watt | DC-DC Converter |
文件: | 总3页 (文件大小:301K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series AM40U-AZ
40 Watt | DC-DC Converter
FEATURES:
• Wide Input 2:1 Range
• Full Internal SMD Technology
• 1600 VDC Isolation
•
•
•
•
Adjustable Output Voltage
Remote ON/OFF Function
Over Load, Voltage & Short Circuit Protection
• Efficiency up to 89%
Operating temperature -40oC to + 85oC
Models
Single output
Input Voltage
(V)
Output Voltage
Output Current
Isolation
(VDC)
1600
Efficiency
Model
(V)
3.3
5
12
15
3.3
5
12
15
3.3
5
12
15
max (A)
(%)
85
86
86
87
86
88
88
89
87
88
89
89
AM40U-1203SAZ
AM40U-1205SAZ
AM40U-1212SAZ
AM40U-1215SAZ
AM40U-2403SAZ
AM40U-2405SAZ
AM40U-2412SAZ
AM40U-2415SAZ
AM40U-4803SAZ
AM40U-4805SAZ
AM40U-4812SAZ
AM40U-4815SAZ
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
8
8
3.3
2.6
8
1600
1600
1600
1600
1600
1600
1600
1600
8
3.3
2.6
8
8
3.3
2.6
1600
1600
1600
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Nominal
Typical
9-18
18-36
Maximum
Units
12
24
48
Voltage range
VDC
36-75
Filter
Start up time
π(Pi) Network
25
ms
12
24
48
36
50
100
100
Absolute Maximum Rating
VDC
Peak Input Voltage time
ms
Input reflected ripple current
20
mA p-p
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Conditions
Typical
Rated
1600
Units
3 sec
VDC
MOhm
pF
>1000
220
Capacitance
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Voltage accuracy
±2
%
Over voltage protection
Over load protection
Short Circuit protection
Short circuit restart
Zener Diode Clamp
135~150
Foldback
%
Continuous
Auto-Restart
110
Thermal shutdown
On Case
ºC
Line voltage regulation
±1
% of Vin
www.aimtec.com
F 051e R12.B
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM40U-AZ
40 Watt | DC-DC Converter
Output Specifications (continued)
Parameters
Conditions
Typical
±2
±0.02
75
Maximum
Units
%
Load voltage regulation (Single)
Temperature coefficient
Ripple & Noise
Iout=10% to 100%
%/oC
mV p-p
%
20MHz Bandwidth
Voltage adjustment range
±10
General Specifications
Parameters
Switching frequency
Conditions
100% load
Typical
300
Maximum
Units
KHz
oC
With derating above 55 oC
(see graph below)
Operating temperature
-40 to +85
Storage temperature
Maximum case temperature
Derating
Cooling
Humidity
-55 to +125
oC
105
95
oC
Above 55 oC
2
%/ oC
Free Air Convection
% RH
g
Case material
Weight
Nickel – coated Copper
60
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Transient recovery time
Transient recovery deviation
2.00 x 2.00 x 0.40 inches
>1 500 000 hrs ( MIL-HDBK-217 F at +25 oC)
1.5mm from case for 10 sec 260
50.81 x 50.81 10.14 mm
oC
uS
500
±4% of Vout
25% load step
Safety Specifications
Parameters
Standards
Designed to meet IEC 60950-1:2001 and EN55022:2006 + A1:2007, Class B
Pin Out Specifications
Single
+V Input
Pin
1
2
-V Input
3
No Pin
4
5
6
+V Output
-V Output
On/Off (option)
www.aimtec.com
F 051e R12.B
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM40U-AZ
40 Watt | DC-DC Converter
Dimensions
Derating
Trimming
Free Air Convection
º
55
C
100
80
Safe Operating Area
60
40
20
0
85
80
100
- 40 - 20
0
20
40
60
º C
Ambient Temperature
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.B
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
相关型号:
©2020 ICPDF网 联系我们和版权申明