AD7751AAN-REF [ADI]

Energy Metering IC With On-Chip Fault Detection; 电能计量IC,具有片内故障检测
AD7751AAN-REF
型号: AD7751AAN-REF
厂家: ADI    ADI
描述:

Energy Metering IC With On-Chip Fault Detection
电能计量IC,具有片内故障检测

文件: 总16页 (文件大小:250K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Energy Metering IC  
With On-Chip Fault Detection  
a
AD7751*  
FEATURES  
The only analog circuitry used in the AD7751 is in the ADCs  
and reference circuit. All other signal processing (e.g., multipli-  
cation and filtering) is carried out in the digital domain. This  
approach provides superior stability and accuracy over extremes  
in environmental conditions and over time.  
High Accuracy, Supports 50 Hz/60 Hz IEC 687/1036  
Less than 0.1% Error Over a Dynamic Range of 500 to 1  
Supplies Average Real Power on the Frequency  
Outputs F1 and F2  
High-Frequency Output CF Is Intended for Calibration  
and Supplies Instantaneous Real Power  
Continuous Monitoring of the Phase and Neutral  
Current Allows Fault Detection in Two-Wire  
Distribution Systems  
AD7751 Uses the Larger of the Two Currents (Phase  
or Neutral) to Bill—Even During a Fault Condition  
Two Logic Outputs (FAULT and REVP) Can be Used to  
Indicate a Potential Miswiring or Fault Condition  
Direct Drive for Electromechanical Counters and  
Two-Phase Stepper Motors (F1 and F2)  
A PGA in the Current Channel Allows the Use of Small  
Values of Shunt and Burden Resistance  
Proprietary ADCs and DSP Provide High Accuracy Over  
Large Variations in Environmental Conditions and Time  
On-Chip Power Supply Monitoring  
On-Chip Creep Protection (No Load Threshold)  
On-Chip Reference 2.5 V ؎ 8% (30 ppm/؇C Typical)  
with External Overdrive Capability  
The AD7751 incorporates a novel fault detection scheme that  
warns of fault conditions and allows the AD7751 to continue  
accurate billing during a fault event. The AD7751 does this  
by continuously monitoring both the phase and neutral (re-  
turn) currents. A fault is indicated when these currents differ by  
more than 12.5%. Billing is continued using the larger of the  
two currents.  
The AD7751 supplies average real power information on the  
low-frequency outputs F1 and F2. These logic outputs may be  
used to directly drive an electromechanical counter or interface  
to an MCU. The CF logic output gives instantaneous real power  
information. This output is intended to be used for calibration  
purposes.  
The AD7751 includes a power supply monitoring circuit on the  
AVDD supply pin. The AD7751 will remain in a reset condition  
until the supply voltage on AVDD reaches 4 V. If the supply falls  
below 4 V, the AD7751 will also be reset and no pulses will be  
issued on F1, F2, and CF.  
Single 5 V Supply, Low Power (15 mW Typical)  
Low-Cost CMOS Process  
Internal phase matching circuitry ensures that the voltage and  
current channels are matched whether the HPF in Channel 1 is  
on or off. The AD7751 also has anticreep protection.  
GENERAL DESCRIPTION  
The AD7751 is a high-accuracy fault-tolerant electrical energy  
measurement IC that is intended for use with 2-wire distribution  
systems. The part specifications surpass the accuracy require-  
ments as quoted in the IEC1036 standard.  
The AD7751 is available in 24-lead DIP and SSOP packages.  
FUNCTIONAL BLOCK DIAGRAM  
FAULT  
AC/DC DV  
DGND  
G0 G1  
AV  
AGND  
DD  
DD  
AD7751  
POWER  
SUPPLY MONITOR  
SIGNAL  
PROCESSING  
BLOCK  
A<>B  
A
V1A  
V1N  
V1B  
...110101...  
ADC  
PGA  
؋
1, 
؋
2, 
؋
8, 
؋
16  
HPF  
A>B  
PHASE  
...110101...  
B
ADC  
CORRECTION  
MULTIPLIER  
B>A  
PGA  
LPF  
؋
1, 
؋
2, 
؋
8, 
؋
16  
V2P  
V2N  
...11011001...  
ADC  
DIGITAL-TO-FREQUENCY  
CONVERTER  
4k⍀  
2.5V  
REFERENCE  
F1  
REF  
CLKIN CLKOUT SCF S0 S1 REVP CF  
F2RESET  
IN/OUT  
*US Patent 5,745,323; 5,760,617; 5,862,069; 5,872,469.  
REV. A  
Information furnished by Analog Devices is believed to be accurate and  
reliable. However, no responsibility is assumed by Analog Devices for its  
use, nor for any infringements of patents or other rights of third parties  
which may result from its use. No license is granted by implication or  
otherwise under any patent or patent rights of Analog Devices.  
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.  
Tel: 781/329-4700  
Fax: 781/326-8703  
World Wide Web Site: http://www.analog.com  
© Analog Devices, Inc., 2000  
(AVDD = DVDD = 5 V ؎ 5%, AGND = DGND = 0 V, On-Chip Reference, CLKIN =  
3.58 MHz, TMIN to TMAX = –40؇C to +85؇C)  
AD7751–SPECIFICATIONS1, 2  
Parameter  
A Version B Version  
Unit  
Test Conditions/Comments  
ACCURACY3  
Measurement Error1 on Channels 1 and 2  
Gain = 1  
Gain = 2  
One Channel with Full-Scale Signal ( 660 mV)  
Over a Dynamic Range 500 to 1  
Over a Dynamic Range 500 to 1  
Over a Dynamic Range 500 to 1  
Over a Dynamic Range 500 to 1  
Line Frequency = 45 Hz to 55 Hz  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
% Reading typ  
% Reading typ  
% Reading typ  
% Reading typ  
Gain = 8  
Gain = 16  
Phase Error1 Between Channels  
V1 Phase Lead 37°  
(PF = 0.8 Capacitive)  
V1 Phase Lag 60°  
0.1  
0.1  
0.2  
0.1  
0.1  
0.2  
Degrees(°) max AC/DC = 0 and AC/DC = 1  
Degrees(°) max AC/DC = 0 and AC/DC = 1  
(PF = 0.5 Inductive)  
AC Power Supply Rejection1  
Output Frequency Variation (CF)  
AC/DC = 1, S0 = S1 = 1, G0 = G1 = 0  
% Reading typ  
V1 = 100 mV rms, V2 = 100 mV rms @ 50 Hz  
Ripple on AVDD of 200 mV rms @ 100 Hz  
AC/DC = 1, S0 = S1 = 1, G0 = G1 = 0  
V1 = 100 mV rms, V2 = 100 mV rms,  
AVDD = DVDD = 5 V 250 mV  
DC Power Supply Rejection1  
Output Frequency Variation (CF)  
0.3  
0.3  
% Reading typ  
FAULT DETECTION1, 4  
Fault Detection Threshold  
Inactive i/p <> Active i/p  
Input Swap Threshold  
Inactive i/p > Active i/p  
Accuracy Fault Mode Operation  
V1A Active, V1B = AGND  
V1B Active, V1A = AGND  
Fault Detection Delay  
See Fault Detection Section  
(V1A or V1B Active)  
12.5  
14  
12.5  
14  
% typ  
% of Active typ (V1A or V1B Active)  
0.1  
0.1  
3
0.1  
0.1  
3
% Reading typ  
% Reading typ  
Second typ  
Over a Dynamic Range 500 to 1  
Over a Dynamic Range 500 to 1  
Swap Delay  
3
3
Second typ  
ANALOG INPUTS  
Maximum Signal Levels  
Input Impedance (DC)  
Bandwidth  
See Analog Inputs Section  
V1A, V1B, V1N, V2N and V2P to AGND  
CLKIN = 3.58 MHz  
CLKIN/256, CLKIN = 3.58 MHz  
See Terminology and Performance Graphs  
External 2.5 V Reference, Gain = 1,  
V1 = V2 = 660 mV dc  
1
390  
14  
20  
4
1
390  
14  
20  
4
V max  
kmin  
kHz typ  
mV max  
% Ideal typ  
ADC Offset Error1  
Gain Error1  
Gain Error Match1  
0.2  
0.2  
% Ideal typ  
External 2.5 V Reference  
REFERENCE INPUT  
REFIN/OUT Input Voltage Range  
2.7  
2.3  
3.2  
10  
2.7  
2.3  
3.2  
10  
V max  
V min  
kmin  
pF max  
2.5 V + 8%  
2.5 V – 8%  
Input Impedance  
Input Capacitance  
ON-CHIP REFERENCE  
Reference Error  
Temperature Coefficient  
Nominal 2.5 V  
200  
30  
200  
30  
60  
mV max  
ppm/°C typ  
ppm/°C max  
CLKIN  
Note All Specifications for CLKIN of 3.58 MHz  
Input Clock Frequency  
4
1
4
1
MHz max  
MHz min  
LOGIC INPUTS5  
SCF, S0, S1, AC/DC,  
RESET, G0 and G1  
Input High Voltage, VINH  
Input Low Voltage, VINL  
Input Current, IIN  
2.4  
0.8  
3
2.4  
0.8  
3
V min  
DVDD = 5 V 5%  
DVDD = 5 V 5%  
Typically 10 nA, VIN = 0 V to DVDD  
V max  
µA max  
pF max  
Input Capacitance, CIN  
10  
10  
–2–  
REV. A  
AD7751  
Parameter  
A Version B Version  
Unit  
Test Conditions/Comments  
LOGIC OUTPUTS4  
F1 and F2  
Output High Voltage, VOH  
ISOURCE = 10 mA  
DVDD = 5 V  
ISINK = 10 mA  
DVDD = 5 V  
4.5  
0.5  
4.5  
0.5  
V min  
V max  
Output Low Voltage, VOL  
CF, FAULT, and REVP  
Output High Voltage, VOH  
ISOURCE = 5 mA  
DVDD = 5 V  
ISINK = 5 mA  
DVDD = 5 V  
4
4
V min  
V max  
Output Low Voltage, VOL  
0.5  
0.5  
POWER SUPPLY  
AVDD  
For Specified Performance  
5 V – 5%  
5 V + 5%  
5 V – 5%  
5 V + 5%  
4.75  
5.25  
4.75  
5.25  
3
4.75  
5.25  
4.75  
5.25  
3
V min  
V max  
V min  
V max  
mA max  
mA max  
DVDD  
AIDD  
DIDD  
Typically 2 mA  
Typically 1.5 mA  
2.5  
2.5  
NOTES  
1See Terminology section for explanation of specifications.  
2See plots in Typical Performance Characteristics graphs.  
3See Fault Detection section of data sheet for explanation of fault detection functionality.  
4Sample tested during initial release and after any redesign or process change that may affect this parameter.  
Specifications subject to change without notice.  
(AVDD = DVDD = 5 V ؎ 5%, AGND = DGND = 0 V, On-Chip Reference, CLKIN = 3.58 MHz,  
TMIN to TMAX = –40؇C to +85؇C)  
TIMING CHARACTERISTICS1, 2  
Parameter  
A, B Versions  
Unit  
Test Conditions/Comments  
3
t1  
t2  
275  
See Table III  
1/2 t2  
ms  
sec  
sec  
ms  
sec  
sec  
F1 and F2 Pulsewidth (Logic Low)  
Output Pulse Period. See Transfer Function Section  
Time Between F1 Falling Edge and F2 Falling Edge  
CF Pulsewidth (Logic High)  
CF Pulse Period. See Transfer Function Section  
Minimum Time Between F1 and F2 Pulse  
t33  
t4  
t5  
t6  
90  
See Table IV  
CLKIN/4  
NOTES  
1Sample tested during initial release and after any redesign or process change that may affect this parameter.  
2See Figure 1.  
3The pulsewidths of F1, F2 and CF are not fixed for higher output frequencies. See Frequency Outputs section.  
Specifications subject to change without notice.  
t
ORDERING GUIDE  
1
Package  
Option  
F1  
Model  
Package Description  
.t  
6
.
t
2
AD7751AAN  
AD7751AARS  
AD7751ABRS  
EVAL-AD7751EB AD7751 Evaluation Board  
AD7751AAN-REF AD7751 Reference Design  
PCB (See AN-563)  
Plastic DIP  
N-24  
Shrink Small Outline Package RS-24  
Shrink Small Outline Package RS-24  
F2  
.t  
3
.t  
t
5
4
CF  
Figure 1. Timing Diagram for Frequency Outputs  
–3–  
REV. A  
AD7751  
ABSOLUTE MAXIMUM RATINGS*  
24-Lead Plastic DIP, Power Dissipation . . . . . . . . . . 450 mW  
(TA = 25°C unless otherwise noted)  
θ
JA Thermal Impedance . . . . . . . . . . . . . . . . . . . . 105°C/W  
Lead Temperature, (Soldering 10 sec) . . . . . . . . . . . 260°C  
AVDD to AGND . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +7 V  
DVDD to DGND . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +7 V  
DVDD to AVDD . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +0.3 V  
Analog Input Voltage to AGND  
24-Lead SSOP, Power Dissipation . . . . . . . . . . . . . . 450 mW  
θ
JA Thermal Impedance . . . . . . . . . . . . . . . . . . . . 112°C/W  
Lead Temperature, Soldering  
Vapor Phase (60 sec) . . . . . . . . . . . . . . . . . . . . . . 215°C  
V1A, V1B, V1N, V2P, and V2N . . . . . . . . . . –6 V to +6 V  
Reference Input Voltage to AGND . . –0.3 V to AVDD + 0.3 V  
Digital Input Voltage to DGND . . . . –0.3 V to DVDD + 0.3 V  
Digital Output Voltage to DGND . . . –0.3 V to DVDD + 0.3 V  
Operating Temperature Range  
Industrial (A, B Versions) . . . . . . . . . . . . . –40°C to +85°C  
Storage Temperature Range . . . . . . . . . . . . –65°C to +150°C  
Junction Temperature . . . . . . . . . . . . . . . . . . . . . . . . . 150°C  
Infrared (15 sec) . . . . . . . . . . . . . . . . . . . . . . . . . . 220°C  
*Stresses above those listed under Absolute Maximum Ratings may cause perma-  
nent damage to the device. This is a stress rating only; functional operation of the  
device at these or any other conditions above those listed in the operational sections  
of this specification is not implied. Exposure to absolute maximum rating condi-  
tions for extended periods may affect device reliability.  
CAUTION  
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily  
accumulate on the human body and test equipment and can discharge without detection. Although  
the AD7751 features proprietary ESD protection circuitry, permanent damage may occur on  
devices subjected to high-energy electrostatic discharges. Therefore, proper ESD precautions are  
recommended to avoid performance degradation or loss of functionality.  
WARNING!  
ESD SENSITIVE DEVICE  
TERMINOLOGY  
MEASUREMENT ERROR  
The error associated with the energy measurement made by the  
AD7751 is defined by the following formula:  
For the ac PSR measurement a reading at nominal supplies  
(5 V) is taken. A 200 mV rms/100 Hz signal is then introduced  
onto the supplies and a second reading obtained under the same  
input signal levels. Any error introduced is expressed as a per-  
centage of reading—see Measurement Error definition.  
Percentage Error =  
For the dc PSR measurement a reading at nominal supplies  
(5 V) is taken. The supplies are then varied 5% and a second  
reading is obtained with the same input signal levels. Any error  
introduced is again expressed as a percentage of reading.  
Energy Registered by the AD7751 – True Energy  
× 100%  
True Energy  
PHASE ERROR BETWEEN CHANNELS  
The HPF (High-Pass Filter) in Channel 1 has a phase lead  
response. To offset this phase response and equalize the phase  
response between channels a phase correction network is also  
placed in Channel 1. The phase correction network matches the  
phase to within 0.1° over a range of 45 Hz to 65 Hz and 0.2°  
over a range 40 Hz to 1 kHz (see Figures 10 and 11).  
GAIN ERROR  
The gain error of the AD7751 is defined as the difference between  
the measured output frequency (minus the offset) and the ideal  
output frequency. It is measured with a gain of 1 in Channel  
V1A. The difference is expressed as a percentage of the ideal  
frequency. The ideal frequency is obtained from the transfer  
function—see Transfer Function section.  
ADC OFFSET ERROR  
This refers to the dc offset associated with the analog inputs to  
the ADCs. It means that with the analog inputs connected to  
AGND the ADCs still see an analog input signal of 1 mV to  
10 mV. However, when the HPF is switched on the offset is  
removed from the current channel and the power calculation is  
not affected by this offset.  
GAIN ERROR MATCH  
The gain error match is defined as the gain error (minus the  
offset) obtained when switching between a gain of 1 and a gain  
of 2, 8, or 16. It is expressed as a percentage of the output  
frequency obtained under a gain of 1. This gives the gain  
error observed when the gain selection is changed from  
1 to 2, 8, or 16.  
POWER SUPPLY REJECTION  
This quantifies the AD7751 measurement error as a percentage  
of reading when the power supplies are varied.  
–4–  
REV. A  
AD7751  
PIN FUNCTION DESCRIPTIONS  
Pin No.  
Mnemonic  
Description  
1
DVDD  
Digital Power Supply. This pin provides the supply voltage for the digital circuitry in the AD7751.  
The supply voltage should be maintained at 5 V 5% for specified operation. This pin should be  
decoupled with a 10 µF capacitor in parallel with a ceramic 100 nF capacitor.  
2
AC/DC  
AVDD  
High-Pass Filter Select. This logic input is used to enable the HPF in Channel 1 (the current  
channel). A Logic 1 on this pin enables the HPF. The associated phase response of this filter has  
been internally compensated over a frequency range of 45 Hz to 1 kHz. The HPF filter should be  
enabled in energy metering applications.  
Analog Power Supply. This pin provides the supply voltage for the analog circuitry in the AD7751.  
The supply should be maintained at 5 V 5% for specified operation. Every effort should be made  
to minimize power supply ripple and noise at this pin by the use of proper decoupling. This pin  
should be decoupled to AGND with a 10 µF capacitor in parallel with a ceramic 100 nF capacitor.  
3
4, 5  
V1A, V1B  
Analog Inputs for Channel 1 (Current Channel). These inputs are fully differential voltage inputs  
with a maximum signal level of 660 mV with respect to Pin V1N for specified operation. The  
maximum signal level at these pins is 1 V with respect to AGND. Both inputs have internal ESD  
protection circuitry and an overvoltage of 6 V can also be sustained on these inputs without risk of  
permanent damage.  
6
V1N  
Negative Input Pin for Differential Voltage Inputs V1A and V1B. The maximum signal level at this  
pin is 1 V with respect to AGND. The input has internal ESD protection circuitry and in addition,  
an overvoltage of 6 V can be sustained without risk of permanent damage. This input should be  
directly connected to the burden resistor and held at a fixed potential, i.e., AGND. See Analog  
Input section.  
7, 8  
V2N, V2P  
Negative and Positive Inputs for Channel 2 (Voltage Channel). These inputs provide a fully differ-  
ential input pair. The maximum differential input voltage is 660 mV for specified operation. The  
maximum signal level at these pins is 1 V with respect to AGND. Both inputs have internal ESD  
protection circuitry and an overvoltage of 6 V can also be sustained on these inputs without risk of  
permanent damage.  
9
RESET  
Reset Pin for the AD7751. A logic low on this pin will hold the ADCs and digital circuitry in a reset  
condition. Bringing this pin logic low will clear the AD7751 internal registers.  
10  
REFIN/OUT  
Provides Access to the On-Chip Voltage Reference. The on-chip reference has a nominal value of  
2.5 V 8% and a typical temperature coefficient of 30 ppm/°C. An external reference source may also  
be connected at this pin. In either case, this pin should be decoupled to AGND with a 1 µF ceramic  
capacitor and 100 nF ceramic capacitor.  
11  
AGND  
Provides the Ground Reference for the Analog Circuitry in the AD7751, i.e., ADCs and Reference.  
This pin should be tied to the analog ground plane of the PCB. The analog ground plane is the  
ground reference for all analog circuitry, e.g., antialiasing filters, current and voltage transduc-  
ers, etc. For good noise suppression the analog ground plane should only be connected to the digital  
ground plane at one point. A star ground configuration will help to keep noisy digital return currents  
away from the analog circuits.  
12  
SCF  
Select Calibration Frequency. This logic input is used to select the frequency on the calibration  
output CF. Table IV shows how the calibration frequencies are selected.  
13, 14  
S1, S0  
These logic inputs are used to select one of four possible frequencies for the digital-to-frequency  
conversion. This offers the designer greater flexibility when designing the energy meter. See Select-  
ing a Frequency for an Energy Meter Application section.  
15, 16  
17  
G1, G0  
CLKIN  
These logic inputs are used to select one of four possible gains for the analog inputs V1A and V1B.  
The possible gains are 1, 2, 8 and 16. See Analog Input section.  
An external clock can be provided at this logic input. Alternatively, a parallel resonant AT crystal can  
be connected across CLKIN and CLKOUT to provide a clock source for the AD7751. The clock  
frequency for specified operation is 3.579545 MHz. Crystal load capacitors of between 22 pF  
and 33 pF (ceramic) should be used with the gate oscillator circuit.  
18  
19  
CLKOUT  
FAULT  
A crystal can be connected across this pin and CLKIN as described above to provide a clock source  
for the AD7751. The CLKOUT pin can drive one CMOS load when an external clock is supplied  
at CLKIN or by gate oscillator circuit.  
This logic output will go active high when a fault condition occurs. A fault is defined as a condition  
under which the signals on V1A and V1B differ by more than 12.5%. The logic output will be reset  
to zero when a fault condition is no longer detected. See Fault Detection section.  
REV. A  
–5–  
AD7751  
Pin No.  
Mnemonic  
Description  
20  
REVP  
This logic output will go logic high when negative power is detected, i.e., when the phase angle  
between the voltage and current signals is greater that 90°. This output is not latched and will be  
reset when positive power is once again detected. The output will go high or low at the same time as  
a pulse is issued on CF.  
21  
DGND  
This provides the ground reference for the digital circuitry in the AD7751, i.e., multiplier, filters  
and digital-to-frequency converter. This pin should be tied to the analog ground plane of the PCB.  
The digital ground plane is the ground reference for all digital circuitry, e.g., counters (mechanical  
and digital), MCUs and indicator LEDs. For good noise suppression the analog ground plane  
should only be connected to the digital ground plane at one point, e.g., a star ground.  
22  
CF  
Calibration Frequency Logic Output. The CF logic output gives instantaneous real power informa-  
tion. This output is intended to be used for calibration purposes. Also see SCF pin description.  
23, 24  
F2, F1  
Low Frequency Logic Outputs. F1 and F2 supply average real power information. The logic outputs  
can be used to directly drive electromechanical counters and two-phase stepper motors. See Transfer  
Function section.  
PIN CONFIGURATION  
DIP and SSOP Packages  
DV  
F1  
24  
1
2
DD  
23 F2  
AC/DC  
AV  
DD  
3
22 CF  
V1A  
V1B  
V1N  
V2N  
V2P  
4
21 DGND  
20 REVP  
19 FAULT  
18 CLKOUT  
5
AD7751  
6
TOP VIEW  
(Not to Scale)  
7
CLKIN  
G0  
8
17  
16  
15  
14  
13  
9
RESET  
REF  
10  
11  
12  
G1  
IN/OUT  
AGND  
SCF  
S0  
S1  
–6–  
REV. A  
Typical Performance CharacteristicsAD7751  
0.50  
0.60  
PF = 1  
PF = 1  
0.40 GAIN = 1  
ON-CHIP REFERENCE  
GAIN = 16  
+85؇C PF = 1  
ON-CHIP REFERENCE  
0.40  
0.30  
0.20  
0.10  
؉85؇C  
0.20  
+25؇C PF = 1  
0.00  
–40؇C  
0.00  
0.20  
–0.10  
؉25؇C  
–0.20  
–0.30  
–0.40  
0.40  
40؇C PF = 1  
0.60  
0.80  
–0.50  
0.01  
0.1  
1
10  
100  
0.01  
0.10  
1.00  
AMPS  
10.0  
100  
100  
100  
AMPS  
TPC 4. Error as a % of Reading (Gain = 16)  
TPC 1. Error as a % of Reading (Gain = 1)  
0.40  
0.25  
PF = 0.5  
GAIN = 1  
PF = 1  
GAIN = 2  
ON-CHIP REFERENCE  
ON-CHIP REFERENCE  
0.30  
0.20  
+85؇C  
0.20  
0.15  
+25؇C PF = 0.5  
0.10  
40؇C PF = 0.5  
0.10  
0.00  
40؇C  
0.05  
0.00  
+25؇C  
0.10  
+85؇C PF = 0.5  
+25؇C PF = 1  
0.20  
0.30  
0.05  
0.01  
0.1  
1
10  
100  
0.01  
0.1  
1
10  
AMPS  
AMPS  
TPC 5. Error as a % of Reading (PF = 0.5, Gain = 1)  
TPC 2. Error as a % of Reading (Gain = 2)  
0.30  
0.20  
PF = 0.5  
GAIN = 2  
+85؇C PF = 0.5  
ON-CHIP REFERENCE  
0.15  
0.20  
0.10  
+85؇C  
0.10  
+25؇C PF = 1  
0.05  
+25؇C  
0.00  
0.00  
0.10  
0.20  
0.30  
+25؇C PF = 0.5  
0.05  
40؇C PF = 0.5  
40؇C  
0.10  
PF = 1  
GAIN = 8  
ON-CHIP REFERENCE  
0.15  
0.01  
0.1  
1
10  
100  
0.01  
0.1  
1
10  
AMPS  
AMPS  
TPC 6. Error as a % of Reading (PF = 0.5, Gain = 2)  
TPC 3. Error as a % of Reading (Gain = 8)  
REV. A  
–7–  
AD7751  
0.20  
0.30  
0.20  
PF = 1  
GAIN = 8  
+25؇C PF=1  
0.10  
EXTERNAL REFERENCE  
0.00  
+85؇C PF=0.5  
0.10  
0.10  
0.20  
0.30  
0.40  
0.50  
0.60  
+25؇C  
0.00  
+85؇C  
+25؇C PF=0.5  
0.10  
0.20  
0.30  
0.40  
PF = 0.5  
GAIN = 8  
ON-CHIP REFERENCE  
40؇C PF=0.5  
40؇C  
0.01 0.1  
1
10  
100  
0.01  
0.1  
1
10  
100  
AMPS  
AMPS  
TPC 7. Error as a % of Reading (PF = 0.5, Gain = 8)  
TPC 10. Error as a % of Reading Over Temperature With  
an External Reference (Gain = 8)  
0.60  
0.60  
PF = 1  
PF = 0.5  
GAIN = 16  
GAIN = 16  
+85؇C PF = 0.5  
+25؇C PF = 1  
0.40  
0.20  
EXTERNAL REFERENCE  
ON-CHIP REFERENCE  
0.40  
+85؇C PF = 0.5  
0.20  
0.00  
+25؇C PF = 1  
0.00  
+25؇C PF = 0.5  
0.20  
0.40  
0.20  
0.40  
0.60  
0.80  
1.00  
40؇C PF = 0.5  
0.60  
40؇C PF = 1  
0.80  
0.01  
0.1  
1
10  
100  
0.01  
0.1  
1
10  
100  
AMPS  
AMPS  
TPC 8. Error as a % of Reading (PF = 0.5, Gain = 16)  
TPC 11. Error as a % of Reading Over Temperature With  
an External Reference (Gain = 16)  
0.20  
PF = 1  
GAIN = 2  
0.15  
0.10  
EXTERNAL REFERENCE  
+85؇C  
0.05  
0.00  
0.05  
0.10  
0.15  
0.20  
0.25  
0.30  
+25؇C  
40؇C  
0.01  
0.1  
1
10  
100  
AMPS  
TPC 9. Error as a % of Reading Over Temperature With  
an External Reference (Gain = 2)  
–8–  
REV. A  
AD7751  
DISTRIBUTION  
DISTRIBUTION  
35  
30  
25  
20  
15  
10  
5
CHARACTERISTICS  
NUMBER OF PTS: 138  
MINIMUM: 11.1367  
MAXIMUM: 10.1775  
MEAN: 1.44576  
STD DEV: 4.6670  
GAIN = 1  
CHARACTERISTICS  
NUMBER OF PTS: 138  
MINIMUM: 4.37379  
MAXIMUM: 5.08496  
MEAN: 0.47494  
16  
14  
12  
10  
8
STD DEV: 1.71819  
GAIN = 16  
TEMP = 25؇ C  
TEMP = 25؇C  
6
4
2
0
0
15  
10  
5  
0
5
10  
15  
؊15  
؊10  
؊5  
0
5
10  
15  
TPC 12. Channel 1 Offset Distribution (Gain = 1)  
TPC 15. Channel 1 Offset Distribution (Gain = 16)  
DISTRIBUTION  
V
DD  
40A TO  
40mA  
CHARACTERISTICS  
10F  
NUMBER OF PTS: 138  
MINIMUM: 7.01774  
MAXIMUM: 6.65068  
MEAN: 0.421358  
STD DEV: 2.974  
GAIN = 2  
21  
18  
15  
12  
9
100nF  
100nF  
10F  
1k⍀  
K9  
AVDD AC/DC AVDD  
U3  
RB  
RB  
V1A  
F1  
F2  
CF  
33nF  
TEMP = 25؇C  
U1  
1k⍀  
AD7751  
V1B  
V1N  
33nF  
REVP  
FAULT  
K10  
PS2501-1  
1k⍀  
33nF  
CLKOUT  
Y1  
22pF  
V2N  
V2P  
REF  
33nF  
33nF  
3.58MHz  
6
931⍀  
930k⍀  
931⍀  
CLKIN  
G0  
V
DD  
22pF  
GAIN  
3
SELECT  
10k⍀  
G1  
220V  
S0  
S1  
0
IN/OUT  
؊15  
؊10  
؊5  
0
5
10  
15  
10F  
100nF  
RB  
SCF  
100nF  
RESET AGND DGND  
GAIN  
TPC 13. Channel 1 Offset Distribution (Gain = 2)  
100nF 100nF  
1
18.2⍀  
8.2⍀  
2
8
2.2⍀  
V
DD  
16  
0.68⍀  
DISTRIBUTION  
35  
TPC 16. Test Circuit for Performance Curves  
CHARACTERISTICS  
NUMBER OF PTS: 138  
MINIMUM: 5.36107  
30  
MAXIMUM: 4.30413  
MEAN: 0.346894  
STD DEV: 1.86651  
25  
GAIN = 8  
TEMP = 25؇C  
20  
15  
10  
5
0
؊15  
؊10  
؊5  
0
5
10  
15  
TPC 14. Channel 1 Offset Distribution (Gain = 8)  
REV. A  
–9–  
AD7751  
THEORY OF OPERATION  
are sinusoidal, the real-power component of the instantaneous  
power signal (i.e., the dc term) is given by:  
The two ADCs digitize the voltage and current signals from the  
current and voltage transducers. These ADCs are 16-bit second  
order sigma-delta converters with an oversampling rate of 900 kHz.  
This analog input structure greatly simplifies transducer interfacing  
by providing a wide dynamic range for direct connection to the  
transducer and also simplifying the antialiasing filter design. A  
programmable gain stage in the current channel further facili-  
tates easy transducer interfacing. A high-pass filter in the current  
channel removes any dc component from the current signal.  
This eliminates any inaccuracies in the real-power calculation  
due to offsets in the voltage or current signals—see HPF and  
Offset Effects section.  
V × I  
2
× cos 60°  
(
)
(1)  
This is the correct real-power calculation.  
INSTANTANEOUS  
POWER SIGNAL  
INSTANTANEOUS  
REAL-POWER SIGNAL  
V
؋
I  
2
The real-power calculation is derived from the instantaneous  
power signal. The instantaneous power signal is generated by  
a direct multiplication of the current and voltage signals. In  
order to extract the real-power component (i.e., the dc compo-  
nent) the instantaneous power signal is low-pass filtered. Figure  
2 illustrates the instantaneous real-power signal and shows how  
the real-power information can be extracted by low-pass filtering  
the instantaneous power signal. This scheme correctly calculates  
real-power for nonsinusoidal current and voltage waveforms at all  
power factors. All signal processing is carried out in the digital  
domain for superior stability over temperature and time.  
0V  
CURRENT  
VOLTAGE  
INSTANTANEOUS  
POWER SIGNAL  
INSTANTANEOUS  
REAL-POWER SIGNAL  
V
؋
I  
2
؋
cos(60؇)  
0V  
DIGITAL-TO-  
FREQUENCY  
CURRENT  
VOLTAGE  
60؇  
HPF  
F1  
CH1  
CH2  
PGA  
ADC  
MULTIPLIER  
F2  
LPF  
Figure 3. DC Component of Instantaneous Power Signal  
Conveys Real-Power Information PF < 1  
DIGITAL-TO-  
FREQUENCY  
ADC  
Nonsinusoidal Voltage and Current  
CF  
The real-power calculation method also holds true for nonsinu-  
soidal current and voltage waveforms. All voltage and current  
waveforms in practical applications will have some harmonic  
content. Using the Fourier Transform, instantaneous voltage  
and current waveforms can be expressed in terms of their  
harmonic content.  
INSTANTANEOUS  
INSTANTANEOUS REAL-  
POWER SIGNAL  
POWER SIGNAL p(t)  
V
؋
I  
p(t) = i(t)
؋
v(t)  
WHERE:  
V
؋
I  
2
v(t) = V
؋
cos(t)  
i(t) = I
؋
cos(t)  
V
؋
I  
{1+cos(2t)}  
V
؋
I  
2
v(t) =V + 2 × V × sin(hωt + α )  
p(t) =  
(2)  
O
h
h
2
h0  
where:  
TIME  
Figure 2. Signal Processing Block Diagram  
v(t) is the instantaneous voltage  
VO is the average value  
The low frequency output of the AD7751 is generated by  
accumulating this real-power information. This low frequency  
inherently means a long accumulation time between output  
pulses. The output frequency is therefore proportional to the  
average real-power. This average real-power information can in  
turn be accumulated (e.g., by a counter) to generate real-energy  
information. Because of its high output frequency and hence  
shorter integration time, the CF output is proportional to the  
instantaneous real-power. This is useful for system calibration  
purposes that would take place under steady load conditions.  
Vh  
is the rms value of voltage harmonic h  
and  
is the phase angle of the voltage harmonic.  
h
i(t) = IO + 2 × I × sin(hωt + β )  
(3)  
h
h
h0  
where:  
i(t) is the instantaneous current  
IO  
Ih  
is the dc component  
is the rms value of current harmonic h  
Power Factor Considerations  
The method used to extract the real-power information from the  
instantaneous power signal (i.e., by low-pass filtering) is still  
valid even when the voltage and current signals are not in phase.  
Figure 3 displays the unity power factor condition and a DPF  
(Displacement Power Factor) = 0.5, i.e., current signal lagging  
the voltage by 60°. If we assume the voltage and current waveforms  
and  
is the phase angle of the current harmonic.  
h
–10–  
REV. A  
AD7751  
Using Equations 2 and 3, the real-power P can be expressed in  
terms of its fundamental real power (P1) and harmonic real  
power (PH).  
The analog inputs V1A, V1B, and V1N have the same maximum  
signal level restrictions as V2P and V2N. However, Channel 1  
has a programmable gain amplifier (PGA) with user-selectable  
gains of 1, 2, 8, or 16—see Table I. These gains facilitate easy  
transducer interfacing.  
P = P1 + PH  
where:  
Figure 5 illustrates the maximum signal levels on V1A, V1B,  
and V1N. The maximum differential voltage is 660 mV divided  
by the gain selection. Again, the differential voltage signal on the  
inputs must be referenced to a common mode, e.g., AGND. The  
maximum common-mode signal is 100 mV as shown in Figure 5.  
P =V × I1 cos(φ1)  
1
1
(4)  
(5)  
φ1 = α1 β1  
V × I × cos(φ )  
and  
PH  
=
h
h
h
h1  
V1A  
V1A, V1B  
φh = αh βh  
DIFFERENTIAL INPUT A  
؎660mV/GAIN MAX PEAK  
+660mV  
GAIN  
V1  
V1  
As can be seen from Equation 5 above, a harmonic real-power  
component is generated for every harmonic, provided that har-  
monic is present in both the voltage and current waveforms.  
The power factor calculation has previously been shown to be  
accurate in the case of a pure sinusoid, therefore the harmonic  
real power must also correctly account for power factor since it  
is made up of a series of pure sinusoids.  
COMMON-MODE  
؎100mV MAX  
V1N  
V1B  
V
CM  
AGND  
V
CM  
DIFFERENTIAL INPUT B  
؎660mV/GAIN MAX PEAK  
660mV  
GAIN  
Note that the input bandwidth of the analog inputs is 14 kHz  
with a master clock frequency of 3.5795 MHz.  
Figure 5. Maximum Signal Levels, Channel 1  
Table I.  
ANALOG INPUTS  
Maximum  
Differential Signal  
Channel V2 (Voltage Channel)  
G1  
G0  
Gain  
The output of the line voltage transducer is connected to the  
AD7751 at this analog input. Channel V2 is a fully differential  
voltage input. The maximum peak differential signal on Chan-  
nel 2 is 660 mV. Figure 4 illustrates the maximum signal levels  
that can be connected to the AD7751 Channel 2.  
0
0
1
1
0
1
0
1
1
2
8
16  
660 mV  
330 mV  
82 mV  
41 mV  
V2  
Typical Connection Diagrams  
+600mV  
V2P  
V2N  
Figure 6 shows a typical connection diagram for Channel V1.  
Here the analog inputs are being used to monitor both the  
phase and neutral currents. Because of the large potential  
difference between the phase and neutral, two CTs (current  
transformers) must be used to provide the isolation. Notice  
both CTs are referenced to AGND (analog ground), hence  
the common-mode voltage is 0 V. The CT turns ratio and  
burden resistor (Rb) are selected to give a peak differential  
voltage of 660 mV/Gain.  
DIFFERENTIAL INPUT  
V2  
؎600mV MAX PEAK  
V
CM  
COMMON-MODE  
؎100mV MAX  
V
CM  
AGND  
600mV  
Figure 4. Maximum Signal Levels, Channel 2  
Channel 2 must be driven from a common-mode voltage, i.e.,  
the differential voltage signal on the input must be referenced to  
a common mode (usually AGND). The analog inputs of the  
AD7751 can be driven with common-mode voltages of up to  
100 mV with respect to AGND. However, best results are  
achieved using a common mode equal to AGND.  
R
V1A  
f
CT  
؎660mV  
GAIN  
Rb  
Rb  
C
C
f
IN  
IP  
AGND  
V1N  
V1B  
؎660mV  
GAIN  
Channel V1 (Current Channel)  
f
The voltage outputs from the current transducers are connected  
to the AD7751 here. Channel V1 has two voltage inputs, namely  
V1A and V1B. These inputs are fully differential with respect to  
V1N. However, at any one time only one is selected to perform  
the power calculation—see Fault Detection section.  
CT  
R
f
PHASE NEUTRAL  
Figure 6. Typical Connection for Channel 1  
REV. A  
–11–  
AD7751  
Figure 7 shows two typical connections for Channel V2. The  
first option uses a PT (Potential Transformer) to provide com-  
plete isolation from the mains voltage. In the second option the  
AD7751 is biased around the neutral wire and a resistor divider  
is used to provide a voltage signal that is proportional to the line  
voltage. Adjusting the ratio of Ra and Rb is also a convenient  
way of carrying out a gain calibration on the meter.  
HPF and Offset Effects  
Figure 9 shows the effect of offsets on the real-power calculation.  
As can be seen from Figure 9, an offset on Channel 1 and Channel  
2 will contribute a dc component after multiplication. Since this  
dc component is extracted by the LPF and used to generate the  
real-power information, the offsets will have contributed a constant  
error to the real power calculation. This problem is easily avoided  
by enabling the HPF (i.e., pin AC/DC is set logic high) in Channel  
1. By removing the offset from at least 1 channel no error com-  
ponent can be generated at dc by the multiplication. Error terms  
at cos(ωt) are removed by the LPF and the digital-to-frequency  
conversion—see Digital-to- Frequency Conversion section.  
R
V2P  
V2N  
f
CT  
C
f
f
؎660mV  
R
f
C
AGND  
Vcos(ωt)+V  
× I × cos(ωt)+ I  
=
(
)
(
)
OS  
OS  
PHASE NEUTRAL  
V × I  
Cf  
+VOS × IOS +VOS × I × cos(ωt)  
Ra  
2
Rb  
VR  
V × I  
2
V2P  
V2N  
+V × IOS × cos(ωt)+  
× cos(2ωt)  
؎660mV  
R
f
C
f
NOTE:  
Ra  
Rb + VR = R  
PHASE NEUTRAL  
R ;  
f
DC COMPONENT (INCLUDING ERROR TERM)  
IS EXTRACTED BY THE LPF FOR REAL-  
POWER CALCULATION  
f
V
؋
 I  
OS  
OS  
Figure 7. Typical Connections for Channel 2  
V 
؋
 I  
2
POWER SUPPLY MONITOR  
The AD7751 contains an on-chip power supply monitor. The  
analog supply (AVDD) is continuously monitored by the AD7751.  
If the supply is less than 4 V 5%, the AD7751 will be reset.  
This is useful to ensure correct device start-up at power-up and  
power-down. The power supply monitor has built-in hysteresis  
and filtering. This gives a high degree of immunity to false  
triggering due to noisy supplies.  
I
؋
 V  
؋
 I  
OS  
V
OS  
2␻  
FREQUENCY RAD/S  
0
Figure 9. Effect of Channel Offsets on the Real Power  
Calculation  
As can be seen from Figure 8 the trigger level is nominally set  
at 4 V. The tolerance on this trigger level is about 5%. The  
power supply and decoupling for the part should be such that  
the ripple at AVDD does not exceed 5 V 5% as specified for  
normal operation.  
The HPF in Channel 1 has an associated phase response that is  
compensated for on-chip. The phase compensation is activated  
when the HPF is enabled and is disabled when the HPF is not  
activated. Figures 10 and 11 show the phase-error between chan-  
nels with the compensation network activated. The AD7751 is  
phase compensated up to 1 kHz as shown. This will ensure correct  
active harmonic power calculation even at low power factors.  
AV  
DD  
5V  
4V  
0.30  
0.25  
0.20  
0.15  
0V  
TIME  
INTERNAL  
RESET  
RESET  
ACTIVE  
RESET  
0.10  
0.05  
0
Figure 8. On-Chip Power Supply Monitor  
0.05  
0.10  
0
100 200 300 400 500 600 700 800 900 1000  
FREQUENCY Hz  
Figure 10. Phase Error Between Channels (0 Hz to 1 kHz)  
REV. A  
–12–  
AD7751  
0.30  
0.25  
0.20  
0.15  
0.10  
0.05  
0
This will remove any ripple. If CF is being used to measure energy,  
e.g., in a microprocessor-based application, the CF output should  
also be averaged to calculate power. However, if an energy  
measurement is being made by counting pulses, no averaging is  
required. Because the outputs F1 and F2 operate at a much  
lower frequency, a lot more averaging of the instantaneous real-  
power signal is carried out. The result is a greatly attenuated  
sinusoidal content and a virtually ripple-free frequency output.  
F1  
DIGITAL-TO-  
FREQUENCY  
0.05  
0.10  
F1  
F2  
V
LPF  
40  
45  
50  
55  
60  
65  
70  
TIME  
MULTIPLIER  
I
FREQUENCY Hz  
DIGITAL-TO-  
FREQUENCY  
CF  
Figure 11. Phase Error Between Channels (40 Hz to 70 Hz)  
CF  
LPF TO EXTRACT  
REAL POWER  
(DC TERM)  
DIGITAL-TO-FREQUENCY CONVERSION  
V 
؋
 I  
2
As previously described, the digital output of the low-pass filter  
after multiplication contains the real-power information. However,  
since this LPF is not an ideal “brick wall” filter implementation,  
the output signal also contains attenuated components at  
the line frequency and its harmonics, i.e., cos(hωt) where  
h = 1, 2, 3, . . . etc.  
TIME  
cos(2t)  
ATTENUATED BY LPF  
2␻  
0
FREQUENCY RAD/S  
The magnitude response of the filter is given by:  
1
INSTANTANEOUS REAL-POWER SIGNAL  
(FREQUENCY DOMAIN)  
|H( f )| =  
(6)  
1+( f/8.9 Hz)  
Figure 12. Real-Power-to-Frequency Conversion  
For a line frequency of 50 Hz, this would give an attenuation of  
the 2 ω (100 Hz) component of approximately –22 dBs. The  
dominating harmonic will be at twice the line frequency, i.e.,  
cos(2ωt) and this is due to the instantaneous power signal.  
FAULT DETECTION  
The AD7751 incorporates a novel fault detection scheme that  
warns of fault conditions and allows the AD7751 to continue  
accurate billing during a fault event. The fault detection function is  
designed to work over a line frequency of 45 Hz to 55 Hz. The  
AD7751 does this by continuously monitoring both the phase  
and neutral (return) currents. A fault is indicated when these  
currents differ by more than 12.5%. However, even during a  
fault the output pulse rate on F1 and F2 is generated using the  
larger of the two currents. Because the AD7751 looks for a  
difference between the signals on V1A and V1B, it is important  
that both current transducers are closely matched.  
Figure 12 shows the instantaneous real-power signal output of  
LPF which still contains a significant amount of instantaneous  
power information, i.e., cos(2ωt). This signal is then passed to  
the digital-to-frequency converter where it is integrated (accumu-  
lated) over time in order to produce an output frequency. This  
accumulation of the signal will suppress or average out any non-  
dc components in the instantaneous real-power signal. The average  
value of a sinusoidal signal is zero. Hence the frequency generated  
by the AD7751 is proportional to the average real power. Figure  
12 shows the digital-to-frequency conversion for steady load  
conditions, i.e., constant voltage and current.  
On power-up the output pulse rate of the AD7751 is proportional  
to the product of the signals on Channel V1A and Channel 2. If  
there is a difference of greater than 12.5% between V1A and  
V1B on power-up, the fault indicator (FAULT) will go active  
after about one second. In addition, if V1B is greater than V1A  
the AD7751 will select V1B as the input. The fault detection is  
automatically disabled when the voltage signal on Channel 1 is less  
than 0.5% of the full-scale input range. This will eliminate false  
detection of a fault due to noise at light loads.  
As can be seen in the diagram, the frequency output CF is seen  
to vary over time, even under steady load conditions. This fre-  
quency variation is primarily due to the cos(2ωt) component in  
the instantaneous real-power signal. The output frequency on CF  
can be up to 128 times higher than the frequency on F1 and F2.  
This higher output frequency is generated by accumulating the  
instantaneous real-power signal over a much shorter time while  
converting it to a frequency. This shorter accumulation period  
means less averaging of the cos(2ωt) component. As a conse-  
quence, some of this instantaneous power signal passes through  
the digital-to-frequency conversion. This will not be a problem  
in the application. Where CF is used for calibration purposes,  
the frequency should be averaged by the frequency counter.  
–13–  
REV. A  
AD7751  
Fault with Active Input Greater than Inactive Input  
Calibration Concerns  
If V1A is the active current input (i.e., is being used for billing),  
and the signal on V1B (inactive input) falls by more than 12.5%  
of V1A, the fault indicator will go active. Both analog inputs are  
filtered and averaged to prevent false triggering of this logic  
output. As a consequence of the filtering, there is a time delay of  
approximately one second on the logic output FAULT after the  
fault event. The FAULT logic output is independent of any activ-  
ity on outputs F1 or F2. Figure 13 illustrates one condition under  
which FAULT becomes active. Since V1A is the active input and it  
is still greater than V1B, billing is maintained on VIA, i.e., no swap  
to the V1B input will occur. V1A remains the active input.  
Typically, when a meter is being calibrated, the voltage and current  
circuits are separated as shown in Figure 15. This means that  
current will only pass through the phase or neutral circuit. Figure  
15 shows current being passed through the phase circuit. This is  
the preferred option since the AD7751 starts billing on the input  
V1A on power-up. The phase circuit CT is connected to V1A in  
the diagram. Since there is no current in the neutral circuit the  
FAULT indicator will come on under these conditions. However,  
this does not affect the accuracy of the calibration and can be  
used as a means to test the functionality of the fault detection.  
Ib  
R
V1A  
f
CT  
FILTER  
AND  
COMPARE  
FAULT  
C
V1A  
V1B  
Rb  
Rb  
V1A  
0V  
f
V1A  
V1A  
V1N  
V1B  
V1B  
PHASE  
A
B
AGND  
V1N  
f
TEST  
CURRENT  
AGND  
Ib  
C
0V  
TO  
MULTIPLIER  
NEUTRAL  
CT  
V1B  
R
f
C
f
Ra  
V1B < 87.5% OF V1A  
Rb  
VR  
V2P  
V2N  
Figure 13. Fault Conditions for Inactive Input Less than  
Active Input  
V
240Vrms  
R
f
NOTE:  
Fault with V1B Greater than V1A  
C
Ra  
R ;  
f
f
Figure 14 illustrates another fault condition. If V1A is the active  
input (i.e., is being used for billing), and the voltage signal on  
V1B (inactive input) becomes greater than 114% of V1A, the  
FAULT indicator goes active and there is also a swap over to  
the V1B input. The analog input V1B has now become the  
active input. Again there is a time delay of about 1.2 second  
associated with this swap. V1A will not swap back to being the  
active channel until V1A becomes greater than 114% of V1B.  
However, the FAULT indicator will become inactive as soon as  
V1A is within 12.5% of V1B. This threshold eliminates poten-  
tial chatter between V1A and V1B.  
Rb + VR = R  
f
Figure 15. Fault Conditions for Inactive Input Greater than  
Active Input  
If the neutral circuit is chosen for the current circuit in the arrange-  
ment shown in Figure 15, it may have implications for the  
calibration accuracy. The AD7751 will power up with the V1A  
input active as normal. However, since there is no current in the  
phase circuit, the signal on V1A is zero. This will cause a FAULT  
to be flagged and the active input to be swapped to V1B (Neutral).  
The meter may be calibrated in this mode but the phase and  
neutral CTs may differ slightly. Since under no-fault condi-  
tions all billing is carried out using the phase CT, the meter  
should be calibrated using the phase circuit. Of course, both  
phase and neutral circuits may be calibrated.  
FILTER  
FAULT  
V1B  
V1A  
AND  
V1A  
V1A  
V1N  
V1B  
V1B  
COMPARE  
A
B
AGND  
TRANSFER FUNCTION  
Frequency Outputs F1 and F2  
0V  
TO  
MULTIPLIER  
The AD7751 calculates the product of two voltage signals (on  
Channel 1 and Channel 2) and then low-pass filters this product  
to extract real-power information. This real-power information  
is then converted to a frequency. The frequency information is  
output on F1 and F2 in the form of active low pulses. The pulse  
rate at these outputs is relatively low, e.g., 0.34 Hz maximum for  
ac signals with S0 = S1 = 0 (see Table III). This means that the  
frequency at these outputs is generated from real-power informa-  
tion accumulated over a relatively long period of time. The result is  
an output frequency that is proportional to the average real  
power. The averaging of the real-power signal is implicit to the  
digital-to-frequency conversion. The output frequency or pulse  
rate is related to the input voltage signals by the following equation.  
V1A < 87.5% OF V1B  
OR  
V1B > 114% OF V1A  
Figure 14. Fault Conditions for Inactive Input Greater than  
Active Input  
5.74 × V1 × V2 × Gain × F14  
(7)  
Freq =  
2
VREF  
–14–  
REV. A  
AD7751  
where,  
Table III.  
Max Frequency  
Freq = Output frequency on F1 and F2 (Hz)  
Max Frequency  
for AC Inputs (Hz)  
S1  
S0  
for DC Inputs (Hz)  
V1  
V2  
= Differential rms voltage signal on Channel 1 (volts)  
= Differential rms voltage signal on Channel 2 (volts)  
0
0
1
1
0
1
0
1
0.68  
1.36  
2.72  
5.44  
0.34  
0.68  
1.36  
2.72  
Gain = 1, 2, 8, or 16, depending on the PGA gain selection  
made using logic inputs G0 and G1  
VREF = The reference voltage (2.5 V 8%) (volts)  
Frequency Output CF  
F1–4 = One of four possible frequencies selected by using the  
The pulse output CF (Calibration Frequency) is intended for  
use during calibration. The output pulse rate on CF can be up  
to 128 times the pulse rate on F1 and F2. The lower the F1–4  
frequency selected the higher the CF scaling. Table IV shows  
how the two frequencies are related depending on the states of  
the logic inputs S0, S1, and SCF. Because of its relatively high  
pulse rate, the frequency at this logic output is proportional to  
the instantaneous real power. As is the case with F1 and F2,  
the frequency is derived from the output of the low-pass filter  
after multiplication. However, because the output frequency is  
high, this real-power information is accumulated over a much  
shorter time. Hence less averaging is carried out in the digital-  
to-frequency conversion. With much less averaging of the real-  
power signal, the CF output is much more responsive to power  
fluctuations (see Signal Processing Block in Figure 2).  
logic inputs S0 and S1 (see Table II)  
Table II.  
S1  
S0  
F1–4 (Hz)  
XTAL/CLKIN*  
21  
0
0
1
1
0
1
0
1
1.7  
3.4  
6.8  
13.6  
3.579 MHz/2  
20  
3.579 MHz/2  
19  
3.579 MHz/2  
18  
3.579 MHz/2  
*F1–4 are a binary fraction of the master clock and will thus vary if the specified  
CLKIN frequency is altered.  
Example 1  
If full-scale differential dc voltages of +660 mV and –660 mV are  
applied to V1 and V2 respectively (660 mV is the maximum  
differential voltage that can be connected to Channel 1 and  
Channel 2), the expected output frequency is calculated as follows.  
Table IV.  
F1–4  
(Hz)  
CF Max for AC Signals  
(Hz)  
Gain  
F1–4  
V1  
=
=
=
=
=
1, G0 = G1 = 0  
1.7 Hz, S0 = S1 = 0  
+660 mV dc = 0.66 volts (rms of dc = dc)  
–660 mV dc = 0.66 volts (rms of dc = |dc|)  
2.5 V (nominal reference value).  
SCF  
S1  
S0  
1
0
1
0
1
0
1
0
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
1.7  
1.7  
3.4  
3.4  
6.8  
6.8  
13.6  
13.6  
128 × F1, F2 = 43.52  
64 × F1, F2 = 21.76  
64 × F1, F2 = 43.52  
32 × F1, F2 = 21.76  
32 × F1, F2 = 43.52  
16 × F1, F2 = 21.76  
16 × F1, F2 = 43.52  
8 × F1, F2 = 21.76  
V2  
V
REF  
NOTE: If the on-chip reference is used, actual output frequencies  
may vary from device to device due to reference tolerance of 8%.  
5.74 × 0.66 × 0.66 ×1×1.7 Hz  
Freq =  
= 0.68 Hz  
(8)  
2.52  
Example 2  
SELECTING A FREQUENCY FOR AN ENERGY METER  
APPLICATION  
In this example, if ac voltages of 660 mV peak are applied to  
V1 and V2, the expected output frequency is calculated as follows.  
As shown in Table II, the user can select one of four frequencies.  
This frequency selection determines the maximum frequency on  
F1 and F2. These outputs are intended to be used to drive the  
energy register (electromechanical or other). Since only four  
different output frequencies can be selected, the available fre-  
quency selection has been optimized for a meter constant of  
100 imp/kWhr with a maximum current of between 10 A and  
120 A. Table V shows the output frequency for several maxi-  
mum currents (IMAX) with a line voltage of 220 V. In all cases  
the meter constant is 100 imp/kWhr.  
Gain  
F1–4  
V1  
V2  
VREF  
=
=
=
=
=
1, G0 = G1 = 0  
1.7 Hz, S0 = S1 = 0  
rms of 660 mV peak ac = 0.66/2 volts  
rms of 660 mV peak ac = 0.66/2 volts  
2.5 V (nominal reference value).  
NOTE: If the on-chip reference is used, actual output frequen-  
cies may vary from device to device due to reference tolerance  
of 8%.  
5.74 × 0.66 × 0.66 × 1 × 1.7 Hz  
Freq =  
= 0.34 Hz  
(9)  
2 × 2 × 2.52  
Table V.  
IMAX  
F1 and F2 (Hz)  
As can be seen from these two example calculations, the maxi-  
mum output frequency for ac inputs is always half of that for dc  
input signals. Table III shows a complete listing of all maximum  
output frequencies.  
12.5 A  
25 A  
40 A  
60 A  
80 A  
0.076  
0.153  
0.244  
0.367  
0.489  
0.733  
120 A  
REV. A  
–15–  
AD7751  
The F1–4 frequencies allow complete coverage of this range of  
output frequencies on F1 and F2. When designing an energy  
meter, the nominal design voltage on Channel 2 (voltage) should  
be set to half-scale to allow for calibration of the meter constant.  
The current channel should also be no more than half-scale when  
the meter sees maximum load. This will allow over-current signals  
and signals with high crest factors to be accommodated. Table  
VI shows the output frequency on F1 and F2 when both analog  
inputs are half-scale. The frequencies listed in Table VI align  
very well with those listed in Table V for maximum load.  
alternating low going pulses. The pulsewidth (t1) is set at 275  
ms and the time between the falling edges of F1 and F2 (t3) is  
approximately half the period of F1 (t2). If, however, the period  
of F1 and F2 falls below 550 ms (1.81 Hz), the pulsewidth of  
F1 and F2 is set to half of their period. The maximum output  
frequencies for F1 and F2 are shown in Table III.  
The high-frequency CF output is intended to be used for  
communications and calibration purposes. CF produces a  
90-ms-wide active high pulse (t4) at a frequency that is propor-  
tional to active power. The CF output frequencies are given in  
Table IV. As in the case of F1 and F2, if the period of CF (t5)  
falls below 180 ms, the CF pulsewidth is set to half the period.  
For example, if the CF frequency is 20 Hz, the CF pulsewidth  
is 25 ms.  
Table VI.  
Frequency on F1 and F2 –  
CH1 and CH2  
S1  
S0  
F1–4  
Half-Scale AC Inputs  
NO LOAD THRESHOLD  
0
0
1
1
0
1
0
1
1.7  
3.4  
6.8  
13.6  
0.085 Hz  
0.17 Hz  
0.34 Hz  
0.68 Hz  
The AD7751 also includes a “no load threshold” and “start-up  
current” feature that will eliminate any creep effects in the  
meter. The AD7751 is designed to issue a minimum output  
frequency. Any load generating a frequency lower than this  
minimum frequency will not cause a pulse to be issued on F1,  
F2, or CF. The minimum output frequency is given as 0.0014%  
of the full-scale output frequency for each of the F1–4 frequency  
selections (see Table II). For example, an energy meter with a  
meter constant of 100 imp/kWhr on F1, F2 using F2 (3.4 Hz),  
the maximum output frequency at F1 or F2 would be 0.0014%  
of 3.4 Hz or 4.76 × 10–5 Hz. This would be 3.05 × 10–3 Hz at  
CF (64 × F1 Hz). In this example the no load threshold would be  
equivalent to 1.7 W of load or a start-up current of 8 mA at 220 V.  
Comparing this value to the IEC1036 specification, which states  
that the meter must start up with a load equal to or less than  
0.4% Ib. For a 5 A(Ib) meter 0.4% of Ib is equivalent to 20 mA.  
When selecting a suitable F1–4 frequency for a meter design, the  
frequency output at IMAX (maximum load) with a meter constant  
of 100 imp/kWhr should be compared with Column 4 of Table  
VI. The frequency that is closest in Table VI will determine the  
best choice of frequency (F1–4). For example if a meter with a  
maximum current of 25 A is being designed, the output frequency  
on F1 and F2, with a meter constant of 100 imp/kWhr, is 0.153 Hz  
at 25 A and 220 V (from Table V). Looking at Table VI, the  
closest frequency to 0.153 Hz in column four is 0.17 Hz. There-  
fore F2 (3.4 Hz—see Table II) is selected for this design.  
Frequency Outputs  
Figure 1 shows a timing diagram for the various frequency  
outputs. The outputs F1 and F2 are the low frequency outputs  
that can be used to directly drive a stepper motor or electrome-  
chanical impulse counter. The F1 and F2 outputs provide two  
OUTLINE DIMENSIONS  
Dimensions shown in inches and (mm).  
24-Lead Plastic DIP  
(N-24)  
24-Shrink Small Outline Package  
(RS-24)  
0.328 (8.33)  
0.318 (8.08)  
1.275 (32.30)  
1.125 (28.60)  
24  
13  
12  
0.280 (7.11)  
0.240 (6.10)  
24  
13  
1
0.325 (8.25)  
0.300 (7.62)  
PIN 1  
0.311 (7.9)  
0.301 (7.64)  
0.212 (5.38)  
0.205 (5.207)  
0.060 (1.52)  
0.015 (0.38)  
0.210  
(5.33)  
MAX  
0.195 (4.95)  
0.115 (2.93)  
1
12  
0.150  
(3.81)  
MIN  
0.200 (5.05)  
0.125 (3.18)  
0.015 (0.381)  
0.008 (0.204)  
0.100  
(2.54)  
BSC  
0.022 (0.558)  
0.014 (0.356)  
0.070 (1.77) SEATING  
PIN 1  
0.07 (1.78)  
0.066 (1.67)  
0.078 (1.98)  
0.068 (1.73)  
PLANE  
0.045 (1.15)  
8°  
0°  
0.0256  
(0.65)  
BSC  
0.015 (0.38)  
0.010 (0.25)  
0.008 (0.203)  
0.002 (0.050)  
SEATING 0.009 (0.229)  
0.037 (0.94)  
0.022 (0.559)  
PLANE  
0.005 (0.127)  
–16–  
REV. A  

相关型号:

AD7751AARS

Energy Metering IC With On-Chip Fault Detection
ADI

AD7751ABRS

Energy Metering IC With On-Chip Fault Detection
ADI

AD7751AN

暂无描述
ADI

AD7751AR

IC SPECIALTY ANALOG CIRCUIT, PDSO24, SOIC-24, Analog IC:Other
ADI

AD7751ARS

IC SPECIALTY ANALOG CIRCUIT, PDSO24, SSOP-24, Analog IC:Other
ADI

AD7751BN

IC SPECIALTY ANALOG CIRCUIT, PDIP24, PLASTIC, DIP-24, Analog IC:Other
ADI

AD7751BRS

Power Metering
ETC

AD7754ARS

IC SPECIALTY ANALOG CIRCUIT, PDSO24, SSOP-24, Analog IC:Other
ADI

AD7754BRS

IC SPECIALTY ANALOG CIRCUIT, PDSO24, SSOP-24, Analog IC:Other
ADI

AD7755

Energy Metering IC with Pulse Output
ADI

AD7755AAN

Energy Metering IC with Pulse Output
ADI

AD7755AAN

SPECIALTY ANALOG CIRCUIT, PDIP24, PLASTIC, DIP-24
ROCHESTER