7B33-01-1 [ADI]

Isolated Voltage Input Signal Conditioning Module -100 Hz Bandwidth;
7B33-01-1
型号: 7B33-01-1
厂家: ADI    ADI
描述:

Isolated Voltage Input Signal Conditioning Module -100 Hz Bandwidth

文件: 总8页 (文件大小:529K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Isolated, Voltage or Current Input  
7B33  
FUNCTIONAL BLOCK DIAGRAM  
FEATURES  
Interfaces, amplifies, and filters unipolar voltage inputs.  
Module provides a precision output of either +1 V to +5 V or  
0 V to +10 V, linear with temperature.  
Module features a nonlinearity of +0.02% maximum and an  
accuracy of +0.1% maximum (+0.01% typical).  
All 7B33 series modules are mix-and-match and Hot  
Swappable.  
APPLICATIONS  
Industrial signal conditioning  
Industrial signal isolation  
Industrial signal filtering  
Figure 1. 7B33 Functional Block Diagram  
The modules feature a maximum nonlinearity of +0.02% and  
are factory calibrated to guarantee a maximum accuracy  
specification of +0.1%.  
PRODUCT OVERVIEW  
The 7B Series offers up to 1500 V rms continuous common  
mode voltage isolation and 120 V rms of field wiring input  
protection. The power supplies necessary to drive each of the  
individual modules input circuitry are internally isolated,  
enabling the 7B Series modules to offer true channel-to-channel  
isolation of the input signals.  
The 7B Series of signal conditioners feature small size, low cost  
and a wide output voltage range for a variety of applications  
including process control and factory-floor environments. The  
single-channel 7B modules accept inputs from a range of  
transducers and are fully rated over the extended -40oC to  
+85oC industrial temperature range. All 7B Series modules are  
rated for a nominal power supply input of +24 VDC; and, for  
maximum flexibility, they will accept supply voltages in the +14  
VDC to +35 VDC range. The input modules, with the exception  
of the 7B21, provide a high-level output voltage that is factory  
configured for either the +1 V to +5 V or 0 V to +10 V range.  
The 7B21 is a unity gain, isolated input module with an  
input/output range of +10V. Output modules are available that  
provide either isolated process current or isolated bipolar  
voltage output. Model 7B39 converts either a +1 V to +5 V input  
to a 4 to 20 mA output or a 0 V to +10 V input to a 0-20 mA  
output. The input/output ranges of the 7B39 are factory  
configured. The 7B22 is a unity gain module that provides an  
isolated +10V output signal. All modules have a universal pin-  
out and may be readily hot-swapped under full power without  
disrupting field wiring. Each module accepts analog transducer  
signals and transfers them to a process control or factory data  
collection system without the inherent noise, non-linearity, drift  
and extraneous voltages which frequently accompany the  
signals.  
The modules directly accept analog signals from  
thermocouples, RTDs, current loop powered transmitters, and  
other process control signals. The 7B Series modules amplify,  
linearize, isolate, protect and convert the transducer output  
signals to standardized analog inputs for high-level analog I/O  
subsystems. The 7B Series Subsystem consists of 19-inch rack-  
compatible hardware (model AC 1363), with universal  
mounting backplane and a family of plug-in (up to 16 per  
backplane) input and output signal conditioning modules. Four-  
, eight-, and sixteen-channel backplanes are available. Each  
backplane incorporates screw terminals for easy power  
connections and field wiring, and includes a 25-pin D-type  
connector for interfacing the high-level single-ended voltage  
outputs to the users equipment. Gold-plated sockets are  
provided on each channel of the backplane to ensure the  
reliability of each module’s electrical connection.  
Rev. 0  
Information furnished by Analog Devices is believed to be accurate and reliable.  
However, no responsibility is assumed by Analog Devices for its use, nor for any  
infringements of patents or other rights of third parties that may result from its use.  
Specifications subject to change without notice. No license is granted by implication  
or otherwise under any patent or patent rights of Analog Devices. Trademarks and  
registered trademarks are the property of their respective companies.  
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.  
Tel: 781.329.4700  
Fax: 781.326.8703  
www.analog.com  
© 2004 Analog Devices, Inc. All rights reserved.  
7B33  
GENERAL DESCRIPTION  
Amplitude modulation is used to implement transformer  
The 7B33 is a single-channel signal conditioning module that  
interfaces, amplifies and filters unipolar voltage inputs and  
provides a protected precision output of either +1 V to +5V or 0  
V to +10 V. To measure a process current input, a plug-on 250  
current sensing resistor, Model AC1391, may be installed  
directly on the 7B backplane, using available pin sockets. The  
external current sense resistor allows the current loop to be  
maintained even when the module is removed from the  
backplane. Model 7B33 features a nonlinearity of +0.02%  
maximum and an accuracy of +0.1% maximum (+0.01%  
typical). To accurately measure low level signals in electrically  
noisy environments, 1500 V rms of galvanic transformer-based  
isolation with a common mode rejection (CMR) of 105 dB @  
50/60 Hz is provided. Rated to operate with a nominal +24  
VDC supply, Model 7B33 is mix-and-match and hot-swappable  
with other 7B Series input modules, so it can be inserted or  
removed from any socket in the same backplane without  
disturbing system power.  
isolation (1500 V rms input-to-output and power). Isolated  
front-end circuitry power is supplied by a DC/DC converter.  
The output section contains a two-pole low pass filter (-3 dB @  
100 Hz), a buffer amplifier and a power oscillator. The two-pole  
output filter and subsequent buffer ensures that a low noise, low  
impedance (<1) signal is available at the output to drive loads  
of 2 kminimum.  
The two input pins of Model 7B33 are fully protected up to 120  
V rms line voltage. A one-pole 100 Hz filter preconditions the  
input signal prior to amplification by a low drift input amplifier.  
Figure 2  
Rev. 0 | Page 2 of 8  
7B33  
7B33 Models Available  
Model  
Input Range  
Output Range  
+1 V to +5 V  
0 V to +10 V  
+1 V to +5 V  
0 V to +10 V  
7B33-01-1  
7B33-01-2  
7B33-01-1  
7B33-01-2  
+1 V to +5 V  
0 V to +5 V  
+4 mA to +20 mA1  
0 mA to +20 mA1  
7B33 Specifications  
(typical @ +23°C ±5°C and Vs = +24 V dc)  
Description  
Model 7B33  
Input Range1  
Standard Ranges  
+1 V to +5 V; 0 V to +5 V (Refer to Model Table)  
Custom Ranges  
Not Available*  
+1 V to +5 V or 0 V to +10 V  
Accuracy1  
Output Range Options (RL > 2 k)  
Initial @ +25°C  
±0.01% Span (±0.1% Span, maximum)  
±0.02% Span, maximum  
N/A4  
Nonlinearity3  
Input Offset vs. Temperature  
Span vs. Temperature  
Output Offset vs. Temperature  
Input Bias Current  
±15 ppm/°C  
±0.003% span/°C  
±0.1 nA  
Input Resistance  
2 MΩ  
Power ON  
Power OFF  
30 k, minimum  
Output Noise  
6 mV peak  
5 MHz Bandwidth  
10 Hz to 100 kHz Bandwidth  
0.1 Hz to 10 Hz Bandwidth  
Bandwidth, -3 dB  
0.4 mV rms  
4 µV peak  
100 Hz  
Output Rise Time, 10% to 90% Span  
Common-Mode Voltage (CMV)  
Input-to-Output and Power  
10 ms  
1500 V rms continuous  
Common Mode Rejection (CMR)  
105 dB  
Input-to-Output and Power @ 50/60 Hz  
Input Protection  
120 V rms, continuous  
Rev. 0 | Page 3 of 8  
7B33  
Input Transient Protection  
ANSI/IEEE C376.90.1-1989  
IEEE-STD 472  
IEC 255-4, Class II  
Output Resistance  
< 1 Ω  
Voltage Output Protection  
Continuous Short to Ground  
Power Supply  
Voltage Range, Operating  
Current  
+14 V dc to +35 V dc  
+20 mA, maximum  
±0.0001%/% of Vs  
DSensitivity  
Mechanical Dimensions  
1.663" x 2.11" x 0.563"  
(42.24 mm x 53.6 mm x 14.3 mm)  
Weight  
60 grams  
Environmental  
Temperature Range  
Operating  
-40°C to +85°C  
Storage  
-40°C to +85°C  
Relative Humidity, 24 hours  
ESD Sensitivity  
RFI Susceptibility  
0 to 90% @ +60°C non-condensing  
IEC 801-2, Level 2  
±0.5% Span error @ 400 MHz, 5 Watt, 3 ft  
Warm-up time required to meet specifications is approximately 10 minutes.  
* Contact factory for OEM requirements.  
1Model 7B33 may be used to measure a process current input by installing a 250 current sensing resistor, such as Model AC1391, on the backplane. With this resistor, the current  
loop is maintained even when the 7B33 module is removed from the backplane.  
2Includes the combined effects of repeatability, hysteresis, and nonlinearity.  
3Nonlinearity is calculated using best-fit straight line method.  
4 Input offset term is included in the output offset specification.  
Specifications subject to change without notice.  
Rev. 0 | Page 4 of 8  
7B33  
PIN CONFIGURATIONS AND FUNCTIONAL DESCRIPTIONS  
Figure 3 7B33 Input Field Connections  
Table 1. Pin Function Descriptions—  
Pin  
No.  
Input Module Function  
Output Module Function  
0
1
2
3
4
5
SENSOR INPUT  
INPUT HIGH  
NOT USED  
OUTPUT HIGH  
OUTPUT LOW  
POWER SUPPLY (DC)  
INPUT VOLTAGE  
INPUT LOW  
POWER SUPPLY (DC)  
OUTPUT VOLTAGE  
Figure 4 . Model 7B Series Module, with pin-out assignments.  
OUTPUT & POWER  
COMMON  
INPUT AND POWER  
COMMON  
ESD CAUTION  
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human  
body and test equipment and can discharge without detection. Although this product features proprietary ESD  
protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges.  
Therefore, proper ESD precautions are recommended to avoid performance degradation or loss of functionality.  
Rev. 0 | Page 5 of 8  
7B33  
OUTLINE DIMENSIONS  
Figure 5. Outline Dimensions  
Rev. 0 | Page 6 of 8  
7B33  
NOTES  
Rev. 0 | Page 7 of 8  
7B33  
NOTES  
©
2004 Analog Devices, Inc. All rights reserved. Trademarks and  
registered trademarks are the property of their respective companies.  
D05175-0-10/04(0)  
Rev. 0 | Page 8 of 8  

相关型号:

7B33-01-2

Isolated Voltage Input Signal Conditioning Module -100 Hz Bandwidth
ADI

7B34

Isolated, Linearized RTD Input
ADI

7B34-01-1

Isolated, Linearized RTD Input
ADI

7B34-01-2

Isolated, Linearized RTD Input
ADI

7B34-02-1

Isolated, Linearized RTD Input
ADI

7B34-02-2

Isolated, Linearized RTD Input
ADI

7B34-03-1

Isolated, Linearized RTD Input
ADI

7B34-03-2

Isolated, Linearized RTD Input
ADI

7B34-04-1

Isolated, Linearized RTD Input
ADI

7B34-04-2

Isolated, Linearized RTD Input
ADI

7B34-05-1

Isolated, Linearized RTD Input
ADI

7B34-05-2

Isolated, Linearized RTD Input
ADI