MV14-8FB [3M]
COPPER ALLOY, TIN FINISH, FORK TERMINAL;型号: | MV14-8FB |
厂家: | 3M ELECTRONICS |
描述: | COPPER ALLOY, TIN FINISH, FORK TERMINAL 端子和端子排 |
文件: | 总2页 (文件大小:15K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Scotchlok™ Terminals
W
C
MV18-4FB/S thru MV10-10FB
L
E
Block Fork, Vinyl Insulated, Brazed Seam
Data Sheet
Wire
Range Stud
(AWG) Size
Maximum
Barrel Barrel Insulation
Product
Number
W
C
L
E
Thickness Length
I.D.
Diameter
MV18-4FB/S 22-18
MV18-6FB/S 22-18
4
6
0.25
0.25
0.85
0.70
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.030
0.040
0.040
0.040
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.070
0.145
0.25
0.30
0.30
0.30
0.25
0.25
0.30
0.30
0.30
0.32
0.32
0.32
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.29
0.29
0.29
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
0.85
1.03
1.03
1.03
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.84
0.84
0.84
0.070
0.070
0.070
0.070
0.090
0.090
0.090
0.090
0.090
0.135
0.135
0.135
0.145
0.145
0.145
0.145
0.170
0.170
0.170
0.170
0.170
0.250
0.250
0.250
MV18-6FB
MV18-8FB
MV18-10FB
22-18
22-18
22-18
6
8
10
4
MV14-4FB/S 16-14
MV14-6FB/S 16-14
6
MV14-6FB
MV14-8FB
MV14-10FB
MV10-6FB
MV10-8FB
MV10-10FB
16-14
16-14
16-14
12-10
12-10
12-10
6
8
10
6
8
10
Installation Information
UL Listed and CSA Certified for use on stranded copper
(AWG) wire only.
CANADIAN STANDARDS
ASSOCIATION
LISTED 314R
UNDERWRITERS
LABORATORIES
STANDARD NO.
Strip away the end 3/8 inch of wire insulation.
STANDARD NO. C22.2
NO. 0. 65
Make the crimp in the proper station of a recommended
3M crimp tool: TH-440, TH-450 (scissor style), or TR-490
(ratchet style) hand tools.
UL 486A
3M FILE NO. LR22190
3M FILE NO. E23438
Specifications
Barrel Crimp (Electrical)
Wire Size:
Barrel Seam:
See Table Above
Brazed
Max. Voltage Rating:
600 V Building Wire
1000 V Signs, Fixtures
and Luminaires
221˚F (105˚C)
Same as Wire
Vinyl
Suitable for factory application on steel or brass tabs UL or
CSA.
Max. Temperature Rating:
Max. Current:
Insulator Material:
Terminal Material:
Plating:
Suitable for field application on brass tabs, strain relief
required, UL only.
ETP Copper
Tin
Engineering Specification
The vinyl-insulated, brazed seam block fork terminal shall
be tin-plated, annealed copper, with the tongue having a
specified stud slot (size 4 thru 10) and a brazed seam
barrel covered by a molded vinyl funnel entry sleeve, color
coded and sized, for a specified (AWG) wire range (22-18,
16-14, 12-10).
Crimp-type terminals shall, electrically and mechanically,
connect to a pre-stripped end of a stranded copper wire:
and have a flat tongue portion with a central opening for
mounting around a screw or stud.
The terminal line shall offer tongue variations in hole
(stud) size (6, 8 10, etc.) and configuration (ring, fork,
block fork, flanged block fork, locking fork, etc.): and
barrel variations in wire (AWG) size (22-18, 16-14, 12-10,
etc.) and construction (non-insulated brazed seam, vinyl
insulated butted seam, nylon insulated with insulation grip,
etc.). The terminal line shall have regulatory agency
coverage (UL Listing, CSA Certification). The terminal
tongue shall be marked with the wire range and
manufacturer’s symbol (ꢀ).
Insulated terminals shall be UL Listed and CSA Certified
for 600 Volts maximum building wire: 1000 Volts
maximum in signs, fixtures and luminaries and have a
maximum operating temperature of 221°F (105°C).
3M and Scotchlok are trademarks of 3M
IMPORTANT NOTICE
Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability
associated with such use.
Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture as of the date of purchase.
3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be,
at 3M’s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will
not be liable for any loss or damage arising from this 3M product, whether direct, indirect, special, incidental or consequential
regardless of the legal theory asserted.
Electrical Products Division
6801 River Place Blvd.
Austin, TX 78726-9000
http://www.3M.com/elpd
Litho in USA.
© 3M 2002 78-8126-0502-6-A