200-6317-9UN-1900 [3M]
PGA289, IC SOCKET;型号: | 200-6317-9UN-1900 |
厂家: | 3M ELECTRONICS |
描述: | PGA289, IC SOCKET |
文件: | 总2页 (文件大小:271K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Test & Burn-In PGA Kit Sockets
Pin Grid Arrays
• Available in 10 x 10 matrix through 25 x 25
matrix
• Used when only a few test sockets are needed
• Provides individual components ready for
assembly
• Open pattern top plate; load only those contacts
needed for your specific device pin pattern
TS-0675-09
Sheet 1 of 2
Date Issued: June 20, 2001
10
Physical
Insulation
Material: Polyethersyfone (PES)
Flammability: UL 94V-0
Color: Black
Marking: 3M Logo & Part Number Identifier
Cam Handle
Material: Stainless Steel
Contact
Material: Beryllium Copper
Plating Options:
30 m" (0.76 mm) Gold over 50 m" (1.3 mm) Nickel
Electrical
Current Rating: 1 Amp
Insulation Resistance: > 1
1012 W at 500 Vdc
ithstanding Voltage: 1000 Vrms at Sea Level
¥
W
Environmental
Temperature Rating Operating: - 55° C to + 150°
C
Mechanical
A: When used as a test socket at room temperature 24°C the socket will last
25,000 actuations.
B: Based on field experience, under normal burn-in conditions up to a
maximum of 150°C, the socket should last an average of four years.
3M Electronic Handling and Protection Division
6801 River Place Blvd.
Austin, TX 78726-9000
For technical, sales or ordering information call 800-328-0411
or visit our website: http://www.3M.com/ehpd
Test & Burn-In PGA Kit Socket
Pin Grid Arrays
Assembly Instructions
1. Load hole plugs into top plate by
pressing fitting into place.
4X Phillips Pan-Hd
#0-80 x 5/16 Long
Assy Screw
Remove from tie bar by cutting
with commercially available 6 1/2
flush diagonal cutter pliers.
2. Place cam plate into recessed
area of base plate, load
"
10X Hole Plugs
1
contacts in desired locations,
being careful that the bent leaf
of the contact is loaded in
correct position ( away from
cam handle. )
3. Insert cam handle into position
in the base plate.
4. Now make a final check that all
contacts are in desired location
and that all are fairly even at the
top. Also check cam to make
sure it is still in position. Now
take the top plate and place into
position and start to lower over
contacts. Start at the rear of the
socket and rotate downward
toward the front and then snap
locating bosses into place.
Several very slight back and
forth motions may be necessary
in order to get contacts to snap
into place. Care should be taken
that too much downward
T
op Plate
Contact
( Order Separately )
Cam Plate
pressure isn't applied which
could bend or damage the
contacts. Insert screws and
tighten.
5. Now make an operation check
by rotating handle 90 . Make a
visual check of movement and
closure of all contacts. Rotate
handle and check the freedom
of movement of cam plate and
that the moving leaf of the
contact clears the entry hole. A
continuity check can be made
before final soldering by placing
device in socket, then closing
and making check. Soldering
should be done with socket in
the open position.
Cam Handle
Base Plate
Standard
Handle
Notes:
1
2
Contact and extra Hole Plugs are ordered separately
.
See Test & Burn-In PGA socket section on page 29 for dimensional information on assembled sockets.
Ordering Information
Part Number
200-6310-9UN-1900
200-6311-9UN-1900
200-6313-9UN-1900
200-6315-9UN-1900
200-6317-9UN-1900
200-6319-9UN-1900
200-6321-9UN-1900
200-6325-9UN-1900
300-6300-CNA-0002B
200-4660-14-1900
Matrix Size
10 x 10
11 x 11
13 x 13
15 x 15
17 x 17
19 x 19
21 x 21
25 x 25
Each
Description
Socket Kit W/O Contacts
Contact–BeCu/Au Plated
Extra Hole Plugs
Set of 10
TS-0675-09
Sheet 2 of 2
3M Electronic Handling and Protection Division
6801 River Place Blvd.
Austin, TX 78726-9000
For technical, sales or ordering information call 800-328-0411
or visit our website: http://www.3M.com/ehpd